HomeMy WebLinkAboutBLD2004-00162 Eagle Managment Plan 411 I
•
cTAT
4,per,
4 k
•
6 � x
Rf39 y0
WASHINGTON DEPARTMENT OF FISH AND WILDLIFE
BALD EAGLE MANAGEMENT PLAN
RCW 77.12.655, WAC 232-12-292
EAGLE TERRITORY: Tala Point 689 2 Jefferson
Occurrence# Nest# County
The following conditions apply to the entire parcel if any portion falls within the distance guidelines.
❑ Any construction or vegetation removal on a lot within 400 feet of a nest tree or roost site will require a
bald eagle management plan tailored for the specific land use and landowners goals. The landowner will
need to contact and consult with the Washington Department of Fish and Wildlife(WDFW)prior to any
clearing or construction. Please contact the WDFW at(360)681- 4276.
1g Any lot located between 400 and 800 feet of a nest tree site:retain all known perch trees and all conifers
>24 inches diameter at breast height(d.b.h). Also retain>50%of pre-clearing or pre-construction conifer
stand with diameter distributions representative-of the original stand (>6 feet tall). Windowing and low
limbing of trees is acceptable provided no more than 30%of the live crown is removed. Recommend
avoiding any tree removal, clearing,heavy equipment use, or external construction between February 1
and August 1 within 800 feet of an active nest. WDFW or a qualified consultant will determine if a nest
is active.
❑ Any lot located>800 feet but within %2 mile from a nest and within 250 horizontal feet of the shoreline
or top of high bank bordering a shoreline: Retain all known perch trees and conifers>24 inches diameter
at breast height(d.b.h.). Also retain>50%of pre-clearing or pre-construction conifer stand with diameter
distributions representative of the original stand (>6 feet tall). Windowing and low limbing of trees is
acceptable provided no more than 30%of the live crown is removed.
I have read and understand the above condition(s)placed on Parcel # 998200331 located in the
NE Quarter of SE Quarter of Section 15 , Township 28N ,Range l EE(East/West meridian)with actual street
address of 804 Tala Shores Drive . If the landowner(s)feel these conditions are too restrictive,
a site specific plan may be developed with the Washington Department of Fish and Wildlife. If the conditions
set forth above are acceptable, please sign below and this will serve as your Bald Eagle Management Plan.
Activities will be periodically monitored and failure to comply with this Plan constitutes a misdemeanor as set
forth in RCW 77.15 0. However,compliance with this plan does not ensure compliance with the Endangered
Species Act 70 f dera1„s to o local laws.
— /y Alan E. and Jill A. Larsen
L o Signature Date Landowner(s) Name (Print)
• - -
804 Tala Shore Dr.
FW Regional Program anager (Date) Address
�L it 1� 6
Port Ludlow, WA 98365-9265
WDFW Wildlife Biologist (Date) City, State,Zip
Send Original To: WDFW (360)437-5189
Region 6 Office Phone
48 Devonshire Road
Montesano, WA 98563-9618
r
0 •
Roof Beam'.97 Uniform Building Code(91 NDS)1 Ver: 6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:34:34 AM
Project: Larsen- Location: Ridge
Summary:
3.5 IN x 14.0 IN x 19.33 FT /Versa-Lam 3080 Fb DF- Boise Cascade
Section Adequate By: 22.7% Controlling Factor: Moment of Inertia/Depth Required 13.08 In
Deflections:
Dead Load: DLD= 0.41 IN
Live Load: LLD= 0.64 IN= U364
Total Load: TLD= 1.05 IN= U221
Reactions(Each End):
Live Load: LL-Rxn= 3141 LB
Dead Load: DL-Rxn= 2033 LB
Total Load: TL-Rxn= 5174 LB
Bearing Length Required(Beam only, support capacity not checked): BL= 1.64 IN
Beam Data:
Span: L= 19.33 FT
Maximum Unbraced Span: Lu= 0.0 FT
Pitch Of Roof: RP= 0 : 12
Live Load Deflect. Criteria: U 240
Total Load Deflect. Criteria: U 180
Roof Loading:
Roof Live Load-Side One: LL1= 25.0 PSF
Roof Dead Load-Side One: DL1= 15.0 PSF
Tributary Width-Side One: TW1= 6.5 FT
Roof Live Load-Side Two: LL2= 25.0 PSF
Roof Dead Load-Side Two: DL2= 15.0 PSF
Tributary Width-Side Two: TW2= 6.5 FT
Roof Duration Factor: Cd= 1.15
Beam Self Weight: BSW= 15 PLF
Slope/Pitch Adjusted Lengths and Loads:
Adjusted Beam Length: Ladj= 19.33 FT
Beam Uniform Live Load: wL= 325 PLF
Beam Uniform Dead Load: wD_adj= 210 PLF
Total Uniform Load: wT= 535 PLF
Properties For:Versa-Lam 3080 Fb DF- Boise Cascade
Bending Stress: Fb= 3080 PSI
Shear Stress: Fv= 285 PSI
Modulus of Elasticity: E= 2000000 PSI
Stress Perpendicular to Grain: Fc_perp= 900 PSI
Adjusted Properties
Fb'(Tension): Fb'= 3482 PSI
Adjustment Factors: Cd=1.15 Cf=0.98
Fv': Fv'= 328 PSI
Adjustment Factors: Cd=1.15
Design Requirements:
Controlling Moment: M= 25002 FT-LB
9.665 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear: V= 4553 LB
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment): Sreq= 86.17 N3
S= 114.33 N3
Area (Shear): Areq= 20.84 N2
A= 49.00 N2
Moment of Inertia (Deflection): Ireq= 652.34 N4
1= 800.33 N4
F `� r> l t 5665
V
I REG:STEREt)
v ,, C ECg
. �,��
. E:
4lr�
RICHARD C. N. Pro^.
- STATE OF WASHING TON
0 •
Floor Joistf 97 Uniform Building Code(91 NDS)1 Ver: 6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:40:19 AM
Protect: LARSEN- Location: loft joist
Summary:
SERIES 600/ 11.875- Boise Cascade x 19.33 FT 16 O.C.
Section Adequate By: 7.0% Controlling Factor: Allowable Deflection
* Hoists were designed for simple spans using the joist manufacturers published values.
If the design does not match the actual joist loading or span conditions in any way,
contact the joist manufacturer for design verification.
Joist Span Deflections:
Dead Load: DLD-Center= 0.16 IN
Live Load: LLD-Center= 0.44 IN= U530
Total Load: TLD-Center= 0.60 IN = U385
Joist Span Left End Reactions (Support A):
Live Load: LL-Rxn-A= 515 LB
Dead Load: DL-Rxn-A= 193 LB
Total Load: TL-Rxn-A= 709 LB
Bearing Length Required(Beam only, support capacity not checked): BL-A= 1.75 IN
Joist Span Right End Reactions(Support B):
Live Load: LL-Rxn-B= 515 LB
Dead Load: DL-Rxn-B= 193 LB
Total Load: TL-Rxn-B= 709 LB
Bearing Length Required (Beam only, support capacity not checked): BL-B= 1.75 IN
Joist Data:
Joist Span Length: L2= 19.33 FT
Floor sheathing applied to top of joists-top of joists fully braced.
Live Load Duration Factor: Cd= 1.00
Live Load Deflect. Criteria: L/ 480
Total Load Deflect. Criteria: L/ 360
Joist Span Loading:
Uniform Floor Loading:
Live Load: LL-2= 40.0 PSF
Dead Load: DL-2= 15.0 PSF
Total Load: TL-2= 55.0 PSF
Total Load Adjusted for Joist Spacing: wT-2= 73 PLF
Properties For: SERIES 600/ 11.875- Boise Cascade
Depth: D= 11.875. IN
Moment Capacity: Mcap= 5190 FT-LB
Shear Capacity: Vcap= 1625 LB
El: EI= 415000000 LB-IN2
End Reaction Capacity: Rcap= 1175 LB
Comparisons With Required Sections:
Controlling Moment: M= 3425 FT-LB
Adjusted Moment Capacity: Mcap-adj= 5190 FT-LB
Controlling Shear: V= 638 LB
Adjusted Shear Capacity: Vcap-adj= 1625 LB
El Required: EI-req= 387717300 LB-IN2
El: El= 415000000 LB-IN2
Maximum End Reaction: Rmax= 709 LB
Adjusted Reaction Capacity: Rcap-adj= 1175 LB
1, u._,E r, r, r! 7 FP,, ,,) ,
r: i t
j Li c MAR 1 6 2004 _,- 5665
1 1,- , ,,k,„7.47 REGISTERED
R IT
. _ _� /�
RICHARD C. N. !'r°^
STATE OF WASHINGTON
• •
•
Floor Joist!'97 Uniform Building Code(91 NDS)1 Ver: 6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:41:32 AM
Project: LARSEN- Location: loft joist-450
Summary:
SERIES 450/ 14- Boise Cascade x 19.33 FT 16 O.C.
Section Adequate By: 10.5% Controlling Factor:Allowable Deflection
* I-joists were designed for simple spans using the joist manufacturers published values.
If the design does not match the actual joist loading or span conditions in any way,
contact the joist manufacturer for design verification.
Joist Span Deflections:
Dead Load: DLD-Center= 0.16 IN
Live Load: LLD-Center= 0.42 IN = L/547
Total Load: TLD-Center= 0.58 IN = L/398
Joist Span Left End Reactions (Support A):
Live Load: LL-Rxn-A= 515 LB
Dead Load: DL-Rxn-A= 193 LB
Total Load: TL-Rxn-A= 709 LB
Bearing Length Required(Beam only, support capacity not checked): BL-A= 1.75 IN
Joist Span Right End Reactions(Support B):
Live Load: LL-Rxn-B= 515 LB
Dead Load: DL-Rxn-B= 193 LB
Total Load: TL-Rxn-B= 709 LB
Bearing Length Required (Beam only, support capacity not checked): BL-B= 1.75 IN
Joist Data:
Joist Span Length: L2= 19.33 FT
Floor sheathing applied to top of joists-top of joists fully braced.
Live Load Duration Factor: Cd= 1.00
Live Load Deflect. Criteria: U 480
Total Load Deflect. Criteria: U 360
Joist Span Loading:
Uniform Floor Loading:
Live Load: LL-2= 40.0 PSF
Dead Load: DL-2= 15.0 PSF
Total Load: TL-2= 55.0 PSF
Total Load Adjusted for Joist Spacing: wT-2= 73 PLF
Properties For: SERIES 450/ 14- Boise Cascade
Depth: D= 14 IN
Moment Capacity: Mcap= 4105 FT-LB
Shear Capacity: Vcap= 1825 LB
El: EI= 425000000 LB-IN2
End Reaction Capacity: Rcap= 1025 LB
Comparisons With Required Sections:
Controlling Moment: M= 3425 FT-LB
Adjusted Moment Capacity: Mcap-adj= 4105 FT-LB
Controlling Shear: V= 624 LB
Adjusted Shear Capacity: Vcap-adj= 1825 LB
El Required: El-req= 384573500 LB-IN2
El: El= 425000000 LB-IN2
Maximum End Reaction: Rmax= 709 LB
Adjusted Reaction Capacity: Rcap-adj= 1025 LB
n E r,.. r- 7 r'.1-
(� i 1i
i ' i
L t MAR 1 6 200� ''
l_
WEPT. OF CJ\ r:_ v[ M� _0 _ ,i
5665
FtEGlSTERED
RRC TECH
f
RICHARD C. N. BF4r:
STATE OF WASHINGTON
0 0
Multi-Loaded Beam'.97 Uniform Building Code(91 NDS)1 Ver: 6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:46:39 AM
Project: LARSEN- Location: loft beam
Summary:
1.75 IN x 11.875 IN x 10.75 FT /Versa-Lam 2800 Fb DF- Boise Cascade
Section Adequate By: 19.5% Controlling Factor: Section Modulus/Depth Required 10.86 In
Center Span Deflections:
Dead Load: DLD-Center= 0.10 IN
Live Load: LLD-Center= 0.25 IN = U524
Total Load: TLD-Center= 0.34 IN= U377
Center Span Left End Reactions(Support A):
Live Load: LL-Rxn-A= 2150 LB
Dead Load: DL-Rxn-A= 841 LB
Total Load: TL-Rxn-A= 2991 LB
Bearing Length Required (Beam only, support capacity not checked): BL-A= 1.90 IN
Center Span Right End Reactions(Support B):
Live Load: LL-Rxn-B= 2150 LB
Dead Load: DL-Rxn-B= 841 LB
Total Load: TL-Rxn-B= 2991 LB
Bearing Length Required(Beam only, support capacity not checked): BL-B= 1.90 IN
Beam Data:
Center Span Length: L2= 10.75 FT
Center Span Unbraced Length-Top of Beam: Lu2-Top= 0.0 FT
Center Span Unbraced Length-Bottom of Beam: Lu2-Bottom= 10.75 FT
Live Load Duration Factor: Cd= 1.00
Live Load Deflect. Criteria: U 360
Total Load Deflect. Criteria: U 240
Center Span Loading:
Uniform Load:
Live Load: wL-2= 400 PLF
Dead Load: wD-2= 150 PLF
Beam Self Weight: BSW= 6 PLF
Total Load: wT-2= 556 PLF
Properties For:Versa-Lam 2800 Fb DF- Boise Cascade
Bending Stress: Fb= 2800 PSI
Shear Stress: Fv= 285 PSI
Modulus of Elasticity: E= 2000000 PSI
Stress Perpendicular to Grain: Fc_perp= 900 PSI
Adjusted Properties
Fb' (Tension): Fb'= 2803 PSI
Adjustment Factors: Cd=1.00 Cf=1.00
Fv': Fv'= 285 PSI
Adjustment Factors: Cd=1.00
Design Requirements:
Controlling Moment: M= 8039 FT-LB
5.375 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s)2
Controlling Shear: V= 2453 LB
At a distance d from left support of span 2(Center Span)
Critical shear created by combining all dead loads and live loads on span(s)2
Comparisons With Required Sections:
Section Modulus (Moment): Sreq= 34.41 N3
S= 41.13 N3
Area(Shear): Areq= 12.91 N2
A= 20.78 N2
Moment of Inertia(Deflection): Ireq= 167.68 N4
1= 244.21 N4
5665
F.,.........1
PMABI : ::
- ! B'
fin? I —^j ,.)� ._
_ _.
• •
Column(97 Uniform Building Code(91 NDS)1 Ver:6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:49:21 AM
Project: LARSEN- Location: center post
Summary:
5.5 IN x 7.5 IN x 10 FT/#2- Douglas Fir-Larch- Dry Use
Section Adequate By: 0.3%
Vertical Reactions:
Live: Vert-LL-Rxn= 10582 LB
Dead: Vert-DL-Rxn= 5830 LB
Total: Vert-TL-Rxn= 16412 LB
Axial Loads:
Live Loads: PL= 10582 LB
Dead Loads: PD= 5715 LB
Column Self Weight: CSW= 115 LB
Total Loads: PT= 16412 LB
Eccentricity(X-X Axis): ex= 0.00 IN
Eccentricity(Y-Y Axis): ey= 0.00 IN
Axial Duration Factor: Cd-Axial= 1.00
Column Data:
Length: L= 10.0 FT
Maximum Unbraced Length (X-X Axis): Lx= 10.0 FT
Maximum Unbraced Length (Y-Y Axis): Ly= 10.0 FT
Column End Condition: Ke= 1.0
Calculated Properties:
Column Section (X-X Axis): dx= 7.50 IN
Column Section (Y-Y Axis): dy= 5.50 IN
Area: A= 41.25 IN2
Section Modulus(X-X Axis): Sx= 51.56 IN3
Section Modulus (Y-Y Axis): Sy= 37.81 IN3
Slenderness Ratio: Lex/dx= 16.00
Ley/dy= 21.8
Properties For: #2- Douglas Fir-Larch
Compressive Stress: Fc= 475 PSI
Modulus of Elasticity: E= 1300000 PSI
Bending Stress(X-X Axis): Fbx= 700 PSI
Bending Stress (Y-Y Axis): Fby= 700 PSI
Adjusted Properties:
Fc': Fc'= 399 PSI
Adjustment Factors: Cd=1.00 Cp=0.84
Column Calculations(Controlling Case Only):
Controlling Load Case:Axial Total Load Only(L+D)
Compressive Stress: fc= 398 PSI
Allowable Compressive Stress: Fc'= 399 PSI
Dr
rt it it
Li MAR 1 6 2004 hr
',..'PT. OF CIA . EvE_OPML ,
5665
REGISTERED
fa.,�R -ITECT
RICHARD C. N, BERr,
STATE OF WASHINGTON
•
Footing Design[97 Uniform Building Code(91 NDS))Ver: 6.00.4
By: Richard Berg , Richard Berg Architects, PC on: 03-15-2004 : 09:51:12 AM
Project: LARSEN- Location: center footing
Summary:
Footing Size: 3.5 FT x 3.5 FT x 10.00 IN
Reinforcement: #4 Bars @ 8.00 IN. O.C. E/W/(5) min.
Footing Loads:
Live Load: PL= 10582 LB
Dead Load: PD= 5495 LB
Total Load: PT= 16077 LB
Ultimate Factored Load: Pu= 25682 LB
Footing Properties:
Allowable Soil Bearing Pressure: Qs= 1500 PSF
Concrete Compressive Strength: F'c= 2500 PSI
Reinforcing Steel Yield Strength: Fy= 40000 PSI
Concrete Reinforcement Cover: c= 3.00 IN
Footing Size:
Width: W= 3.5 FT
Length: L= 3.5 FT
Depth: Depth= 10.00 IN
Effective Depth to Top Layer of Steel: d= 6.25 IN
Column and Baseplate Size:
Column Type: (Wood)
Column Width: m= 6.00 IN
Column Depth: n= 8.00 IN
Bearing Calculations:
Ultimate Bearing Pressure: Qu= 1312 PSF
Effective Allowable Soil Bearing Pressure: Qe= 1375 PSF
Required Footing Area: Areq= 11.69 SF
Area Provided: A= 12.25 SF
Baseplate Bearing:
Bearing Required: Bearing= 25682 LB
Allowable Bearing: Bearing-Allow= 142800 LB
Beam Shear Calculations(One Way Shear):
Beam Shear: Vu1= 9019 LB
Allowable Beam Shear: vc1= 22312 LB
Punching Shear Calculations (Two way shear):
Critical Perimeter: Bo= 53.00 IN
Punching Shear: Vu2= 23141 LB
Allowable Punching Shear(ACI 11-35): vc2-a= 70391 LB
Allowable Punching Shear(ACI 11-36): vc2-b= 94562 LB
Allowable Punching Shear(ACI 11-37): vc2-c= 56312 LB
Controlling Allowable Punching Shear: vc2= 56312 LB
Bending Calculations:
Factored Moment: Mu= 134833 IN-LB
Nominal Moment Strength: Mn= 213014 IN-LB
Reinforcement Calculations:
Concrete Compressive Block Depth: a= 0.44 IN
Steel Required Based on Moment: As(1)= 0.61 IN2
Minimum Code Required Reinforcement(Shrinkage/Temperature ACI-10.5.4): As(2)= 0.84 IN2
Controlling Reinforcing Steel: As-reqd= 0.84 IN2
Selected Reinforcement: #4 Bars @ 8.00 IN. O.C. E/W/(5) Min.
Reinforcement Area Provided: As= 0.98 IN2
Development Length Calculations:
Development Length Required: Ld= 15.00 IN
Development Length Supplied: Ld-sup= 18.00 IN