BUILDING PERMIT
Jefferson County Department of Community Development
621 Sheridan Street, Port Townsend, WA 98368
(360)379-4450 FAX (360)379-4451
PERMIT#: BLD04-00448
SITE ADDRESS: 813 THORNDYKE RD Received Date 06/30/2004
PORT LUDLOW, 98365 Issue Date 08/27/2004
APPLICANT: RAYMOND STELK
ARLENE STELK PHONE: (360) 437-7922
133A OSPREY RIDGE DR C It'i 3o L -Oo-?
PORT LUDLOW WA 98365
SUBDIVISION: BRIDGEHAVEN DIV 5
PARCEL NUMBER: 935100011 Block: Lot: 12
Section: 9 Township: 27 N Range: 01 E
CONTRACTOR: FOX HOMES LLC
2615 JAHN AVE NW STE E4 PHONE: (253) 858-2614
GIG HARBOR WA 98335
Contractor's License: FOXHOL*015PL Expires: 09/20/2005
PROJECT DESCRIPTION: NEW SFR W/ATTACHED GARAGE
ALSO 120 GAL AG PROPANE TANK
REQUIRED INSPECTIONS:
[x; SETBACKS:
[li UFFER: 4 I 2-6
.14 Footing: l>K W -ei
kr Foundation: .' i ,'3, (16 `
IS Stormwater FINAL Approval:
Underground Plumbing:
0 Underground Insul tion:
Shear Wall :
Framing: Q w b i 4
Plumbing: • , 5 J
,.-
tyl., Propane Tank/Lines: ! _
- 1�5i
Insulation: # . I ,
b( Sheetrock: /, es•4r,if ,
Septic Sytem Final Ap: oval: r
Road Approach Final Approval:
[ ] Zoo. • Final Approval:
•ccupancy Approval:
HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION
THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED
BUILDING INSPECTION HOT-LINE 379-4455. CALL 24 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS.
Office Hours 9:00 a.m. -4:30 p.m.
HOT LINE AVAILABLE 24 HOURS A DAY
SPECIAL CONDITIONS APPLY-SEE REVERSE
SPECIAL CONDITIONS FOR #SE t BLD04-004 •48
1.) A vegetative buffer of 25-feet shall be permanently maintained from the top or edge of the
Landslide Hazard Area. All buffers shall be measured perpendicularly from the top of the
Landslide Hazard Area.
2.) A Geotechnical Report dated May 14, 2004 prepared by NTI Engineering and Surveying
was submitted in conjunction with this application. The report addressed the stability of
the geologic hazard area. A setback of no less than 25-feet shall be measured
perpendicularly from the top or toe of the geologic hazard area to the proposed
foundation.
3.) Landslide Hazard Areas and their associated buffers shall remain naturally vegetated.
Should buffer disturbance occur during construction, the Unified Development Code
(UDC)Administrator shall require replanting with native vegetation. No alterations shall be
made to the Landslide Hazard Area or its associated buffer without prior authorization by
the UDC Administrator.
4.) Prior to and during approved construction activities, the perimeter of the landslide hazard
area buffer shall be marked with a temporary sign. The sign shall be placed in such a
manner that it can be directly observed from the construction area. The sign shall contain
the following statement: "Landslide Hazard Area and Buffer- Do not Remove or Alter
Existing Vegetation."
5.) All construction activities shall not encroach upon the landslide hazard area buffer. This
includes the storage or preparation of materials.
6.) The applicant shall permanently separate the boundary of the Landslide Hazard Area
Buffer from the remainder of the subject property through installing logs, trees, a hedge
row, or any other prominent physical marking approved by the UDC Administrator.
7.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water
quality degradation. The submitted proposal does not require additional aquifer
protection measures. However, during construction the project shall follow the Best
Management Practices (BMPs) and facility design standards as identified and defined in
the Stormwater Management Manual for the Puget Sound Basin.
8.) To help prevent seawater from intruding landward into underground aquifers, all new
development activity on Marrowstone Island, Indian Island and within 1/4 mile of any
marine shoreline shall be required to infiltrate all stormwater runoff onsite.
9.) VOLUNTARY MEASURES OF COASTAL &AT RISK SIPZ:
Water conservation measures:
1. Roof and other intercepted precipitation shall be routed to on-site detention ponds
and/or other approved means and allowed to be released to the soil slowly.
2. Water collected from Storm water and roof catchments may be used for watering
lawns and gardens. Unless catchment water has been treated to meet drinking water
standards, there shall be no cross connections allowed between the potable supply and
impounded water.
3. Water withdrawn from wells on each property shall not be used for watering of lawns
and/or gardens.
4. Ground water withdrawn from each property shall be restricted to a rate of three (3)
gallons per minute.
5. Installation of water conserving fixtures such as low flow toilets, faucets and shower
restrictors and other water saving plumbing fixtures.
6. Landscaping plan (xeriscaping, native vegetation with minimal amounts of irrigation).
Please NOTE that the above listed measures are not intended to be exhaustive, but rather
is intended to be illustrative of the types of water conservation measures.
10.) VOLUNTARY MEASURES OF COASTAL &AT RISK SIPZ:
1. Installation of a flow meter.
2. On-going well monitoring for chloride concentration.
3. Submittal of monitoring data to County.
11.) MANDATORY MEASURES L SIPZ:
9 R COASTA IIilk
1. For proof of potable water on a building permit application, applicant must utilize
pproved public water system if available.
2. If public water is unavailable, a qualifying alternative system may be used as proof of
potable water or an individual well may be used as proof of potable water subject to the
following requirement:
a. Chloride concentration of a laboratory-certified well water sample submitted with
building permit application.
3. If public water is unavailable, a qualifying alternative system may be used as proof of
potable water.
12.) The property owner shall comply with Water Conservation Measures (per list maintained
by the UDC Administrator).
13.) The project shall adhere to the Best Management Practices (BMPs) to control stormwater,
erosion and sediment during construction. BMPs shall address permanent measures to
stabilize soil exposed during construction, and in the design and operation of stormwater
and drainage control systems.
14.) An Engineered Stormwater Site Plan dated August 2, 2004 prepared by Tillman
Engineering has been submitted and approved by the Department of Community
Development. Once the subject permit has been issued the applicant shall fully
implement the provisions of the submitted plan and contact the Jefferson County
Department of Community Development to arrange a schedule to inspect the property for
plan compliance. A Certificate of Occupancy will not be issued until the Department
verifies plan compliance. No clearing for roadways or utilities shall occur on the project
site until clearing necessary for the installation of temporary sedimentation and erosion
control measures have been completed.
15.) Outdoor residential storage shall be maintained in an orderly manner and shall create no
fire, safety, health or sanitary hazard.
16.) Not more than two (2) unlicensed or inoperable vehicles shall be stored on any lot less
than one-haif acre unless totally screened from view of neighboring dwellings and
rights-of-way. Such screening shall meet all applicable performance and development
standards specific to the district in which the storage is kept, and shall be in keeping with
the character of the area. Screening shall meet the requirements of Unified Development
Code (UDC) Section 6. Outdoor storage of thirteen (13) or more unlicensed or inoperable
vehicles is prohibited except in those districts where specified as an automobile wrecking
yard or junk (or salvage) yard and allowed as a Permitted Use in Table 3-1 of the UDC,
and such storage shall meet the requirements of UDC Section 4.10. In no case, shall any
such unlicensed or inoperable vehiclesbe stored in an Environmentally Sensitive Area
(ESA).
17.) Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of
impervious surface which includes roof tops, driveways, concrete, etc.
18.) The building height i not to exceed 35 feet.
19.) Minimum setback from Thorndyke Road right-of-way shall be 20 feet. Minimum side yard
setbacks shall be 5 feet. MINIMUM SETBACK FROM TOP OF BANK(LANDSLIDE
HAZARD AREA) SHALL BE 25 FEET TO FOUNDATION PER GEOTECHNICAL
REPORT DATED MAY 14, 2004 PREPARED BY NTI.
20.) Exterior lighting for residential uses shall not exceed twenty feet(20') in height from the
finished grade, excepting when such lighting is an integral part of a building or structure.
Ground level lighting is encouraged.
21.) Lighting fixtures shall be designed and hooded to prevent the light source from being
directly visible from outside the boundaries of the property. The intensity or brightness of
all lighting, during construction and after project completion shall not adversely affect the
use of surrounding properties or adjoining rights-of-way.
22.) A minimum of two (2) on-site parking spaces shall be provided for the single family
residence.
mik
23.) NOTE: SETBACK FROM TOOF BANK TO SW CORNER 0
O
FOUNDATION SHALL BE NO LESS THAN 25 FEET PER GEOTECHNICALD REPORT
DATED MAY 14, 2004 PREPARED BY NTI.
GEOLOGIST SHALL DETERMINE THE TOP OF BANK OF THE LANDSLIDE HAZARD
AREA AS WELL AS STAKE THE 25 FOOT SETBACK FROM THE TOP OF BANK. THIS
STAKING SHALL BE PERPENDICULAR TO THE TOP OF THE BANK AND
ESTABLISHED PRIOR TO POURING OF ANY CONCRETE AND PRIOR TO
EXCAVATION OF FOUNDATION.
24.) GEOTECH CONDITION: IT WILL BE NECESSARY TO MAINTAIN GROUND COVER
IN ORDER TO REDUCE EROSION FROM SURFACE RUNOFF. ANY BARE AREAS
THAT DEVELOP, ON THE UPLAND OR BLUFF, SHOULD BE REVEGETATED.
NATIVE DEEP-ROOTED VEGETATION THAT REQUIRES LITTLE OR NO IRRIGATION
WOULD BE THE MOST BENEFICIAL. PLEASE CONSULT THE ENCLOSED
PUBLICATIONS FOR FUTHER INFORMATION.
25.) GEOTECH CONDITION: VEGETATION ON THE BLUFF FACE PROVIDES
STABILIZATION TO THE BLUFF FACE SOILS AND HELPS REMOVE WATER FROM
THE SOIL. EXISTING ESTABLISHED VEGETATION SHOULD BE LEFT
UNDISTURBED. IF A BETTER VIEW IS DESIRED, MINOR LIMBING AND PRUNING
SHOULD BE DONE IN SUCH A WAY THAT MINIMIZES DISTURBANCE TO THE SOIL
AND ROOT ZONE AND THAT INSURES THE CONTINUED HEALTH OF THE
VEGETATION. TREES SHOULD NOT BE TOPPED.
26.) GEOTECH CONDITION: HEAVY IRRIGATION OR OTHER ACTIVITIES THAT WOULD
CONTRIBUTE LARGE QUANTITIES OF WATER TO THE SOIL SHOULD BE AVOIDED.
27.) GEOTECH CONDITION: SURFACE RUNOFF FROM HARD SURFACES SUCH AS
ROOFS, DRIVEWAYS, WALKWAYS AND PATIOS SHOULD BE CONTROLLED AND
ROUTED TO A DRAINAGE CONTROL DEVICE SUCH THAT SURFACE WATER
DISCHARGE TO ADJACENT PROPERTIES DOES NOT SIGNIFICANTLY EXCEED
PREDEVELOPMENT CONDITIONS. REPORTEDLY, A NEIGHBOR HAS PURCHASED
THE PROPERTY AT THE BASE OF THE BLUFF AND HAS AGREED TO ALLOW MR.
STELK TO TIGHTLINE THE RUNOFF TO THE BASE OF THE BLUFF. THIS OPTION
WOULD BE BETTER, FROM A BLUFF STABILITY STANDPOINT, THAN
INFILTRATING THE WATER ON THE UPLAND. AN ENGINEERED DRAINAGE AND
EROSION CONTROL PLAN SHOULD BE DEVELOPED FOR THIS PROPERTY TO
ADDRESS THESE ISSUES AND THAT CONFORMS TO ALL COUNTY, STATE, ETC.
REGULATIONS.
28.) GEOTECH CONDITION: DRAINAGE ROUTES FROM OFF SITE THAT COULD
POTENTIALLY ALLOW RUNOFF TO FLOW ONTO THE PROPERTY SHOULD BE
ADDRESSED IN THE ENGINEERED DRAINAGE AND EROSION CONTROL PLAN
SUCH THAT THIS POTENTIAL RUNOFF IS CONTROLLED OR REDIRECTED IN
ORDER TO PREVENT DAMAGE TO THE BLUFF. LIKEWISE, THIS SHOULD
CONFORM TO ALL APPLICABLE CODES AND REGULATIONS.
29.) GEOTECH CONDITION: SILT FENCES OR OTHER SEDIMENT CONTROL DEVICES
MAY BE NEEDED DURING CONSTRUCTION SUCH THAT SEDIMENTATION TO
ADJACENT PROPERTIES DOES NOT SIGNIFICANTLY EXCEED PREDEVELOPMENT
CONDITIONS.
30.) GEOTECH CONDITION: DRAINAGE CONTROL DEVICES SHOULD BE MAINTAINED
IN GOOD WORKING ORDER AND INSPECTED AT LEAST ONCE A YEAR.
31.) GEOTECH CONDITIO •
N. •PLOD TABLE 18-1-A OF THE UBC (SEE APPENDIX), THE
ALLOWABLE FOUNDATION PRESSURE FOR THE SANDY SOIL OBSERVED IN THE
TEST PITS ON SITE IS 1500 POUNDS PER SQUARE FOOT(PCF). THIS VALUE CAN
BE INCREASED UP TO A MAXIMUM VALUE OF 4500 PCF SUBJECT TO FOOTNOTE
2 OF THE TABLE.
FOOTNOTE 2 READS: ALL VALUES OF ALLOWABLE FOUNDATION PRESURE ARE
FOR FOOTINGS HAVING A MINIMUM WIDTH OF 12 INCHES (305 MM)AND A
MINIMUM DEPTH OF 12 INCHES (305 MM) INTO NATURAL GRADE. EXCEPT AS IN
FOOTNOTE 7, AN INCREASE OF 20 PERCENT SHALL BE ALLOWED FOR EACH
ADDITIONAL FOOT(305 MM) OF WIDTH OR DEPTH TO A MAXIMUM VALUE OF
THREE TIMES THE DESIGNATED VALUE. ADDITIONALLY, AN INCREASE OF ONE
THIRD SHALL BE PERMITTED WHEN CONSIDERING LOAD COMBINATIONS,
INCLUDING WIND OR EARTHQUAKE LOADS, AS PERMITTED BY SECTION 1612.3.2.
FOOTNOTE 7 READS: NO INCREASE FOR WIDTH IS ALLOWED.
32.) A report dated July 19, 2004 prepared by Robert M. Pride, Inc. was submitted with regards
to the landslide hazard area. The report identified a minimum setback of 25 feet from the
top of bank of the landslide hazard area to the foundation.
33.) ROBERT PRIDE, INC. REP T DATED 7/19/2004
FOUNDATION RECOMMENDATIONS: ili
THE NEW RESIDENCE SHOULD BE SUPPORTED ON CONTINUOUS BEARING
WALL FOOTINGS THAT EXTEND A MINIMUM DEPTH OF 18 INCHES BELOW FINAL
GRADE. IT IS RECOMMENDED THAT THE SOUTHWESTERLY FOUNDATION
WALLS BE LOCATED NO CLOSER THAN 25 FEET TO THE TOP OF THE EXISTING
SLOPE. AN ALLOWABLE SOIL BEARING VALUE OF 2000 PSF AND 2000 PSF MAY
BE USED FOR THE LIGHTLY LOADED HOUSE FOOTINGS FOUNDED ON NATIVE
SOILS AND PROPERLY COMPACTED FILL, RESPECTIIVELY. THIS VALUE MAY BE
INCREASED TO 4000 PSF FOR RETAINING WALL FOOTINGS THAT ARE AT LEAST
24 INCHES IN WIDTH. SETTLEMENT OF FOOTINGS FOUNDED ON ADEQUATE
BEARING SOILS WILL BE MINIMAL.
RESISTANCE TO LATERAL LOADS ON THE STRUCTURE CAN BE PROVIDED BY
PASSIVE EARTH PRESSURE ON FOOTINGS AND THE STEM WALLS. A
RECOMMENDATION OF 300 PCF FOR PASSIVE PRESSURE, AND A COEFFICIENT
OF SLIDING FRICTION OF 0.5. RETAINING WALLS SHOULD BE DESIGNED FOR AN
ACTIVE EARTH PRESSURE OF 30 PCF, AND THEY SHOULD HAVE A FOUNDATION
SUBDRAIN TO ELIMINATE HYDROSTATIC PRESSURE BUILDUP. ALL RETAINING
WALLS SHOULD BE BACKFILLED WITH SOIL COMPACTED TO 90% OF THEIR
MAXIMUM DENSITY TO REDUCE THE POTENTIAL FOR FUTURE SETTLEMENT
UNDER PROPOSED CONCRETE WALKWAYS AND PORCH SLABS.
EXTERIOR SLABS-ON-GRADE
CONCRETE SLABS MAY BE POURED DIRECTLY ON THE VERY DENSE GACIAL
SOILS OR COMPACTED FILL THAT ARE EXPECTED TO BE EXPOSED AT FINAL
GRADE. CONTROL JOINTS SHOULD BE INCLUDED ON ABOUT TEN FOOT
CENTERS ACROSS THE SLAB SECTIONS TO MINIMIZE SHRINKAGE CRACKING. IF
THE CONCRETE IS POURED WITH A LOW SLUMP, REINFORCING STEEL IS NOT
REQUIRED FOR ANY SLABS SUPPORTED ON NATIVE OR COMPACT SOILS. ALL
CONCRETE SHOULD BE PLACED IN ACCORDANCE WITH ACI GUIDELINES.
DRAINAGE:
IN ADDITION TO THE FOUNDATION DRAINS AROUND THE PERIMETER OF THE
BASEMENT WALL FOOTINGS, THERE WILL BE DRAINS AND ROOF DRAINS THAT
WILL COLLECT STORMWATER RUNOFF. ALL OF THIS WATER SHOULD BE
TIGHTLINED TO THE STREET AT THE FRONT OF THE PROPERTY, OR TO A
SUITABLE INFILTRATION TRENCH THAT IS AT LEAST 100 FEET WEST OF THE TOP
OF SLOPE. EVERY EFFORT SHOULD BE MADE TO PREVENT SURFACE WATER
RUNOFF OVER THE TOP OF THE REAR YARD SLOPE, AND TO PREVENT
EXCESSIVE INFILTRATION INTO THE UPPER SOILS NEAR THE STEEP SLOPE.
SUMMARY:
ROBERT M. PRIDE, INC. HAS DISCUSSED THEIR RECOMMENDATIONS FOR
CONTINUOUS BEARING WALL FOOTINGS WITH THE STRUCTURAL ENGINEER
WHO IS IN THE PROCESS OF REVISING THE HOUSE DRAWINGS.
CONSTRUCTION MONITORING AND CONSULTATION SERVICES SHOULD ALSO BE
PROVIDED TO VERIFY THAT SUBSURFACE CONDITIONS ARE SIMILAR TO THOSE
DESCRIBED IN OUR REPORT. SHOULD CONDITIONS BE REVEALED DURING
CONSTRUCTION THAT DIFFER FROM THE ANTICIPATED SUBSURFACE PROFILE,
WE WILL EVALUATE THOSE CONDITIONS AND PROVIDE ALTERNATIVE
RECOMMENDATIONS WHERE APPROPRIATE.
34.) THE STORMWATER INFILTRATION BED SHALL NOT BE INSTALLED AT A DEPTH
GREATER THAN THE ONSITE SEWAGE SYSTEM DUE TO LIMITED SETBACK.
I:\F_BLD_permit_Buildng.rpt
10/29/1999
MLA04-00402
SUI.LDING PERMIT APPLICA N Review Type: I
Jefferson County Department of Community Development
621 Sheridan Street Port Townsend, WA 98368
PERMIT #: BLD04-00448 Received Date: 6/30/2004
SITE ADDRESS: 813 THORNDYKE RD 1
PORT LUDLOW, 98365
OWNER: RAYMOND STELK PHONE: (360)437-7922
ARLENE STELK
133A OSPREY RIDGE DR
PORT LUDLOW WA 98365
SUBDIVISION: BRIDGEHAVEN DIV 5 Block: Lot: 12
PARCEL NUMBER: 935100011 Section: 9 Township: 27 N Range: 01 E
CONTRACTOR: FOX HOMES LLC PHONE: (253) 858-2614
2615 JAHN AVE NW STE E4
GIG HARBOR WA 98335
Contractor's License FOXHOL*015PL Expires 9/20/2005
REPRESENTATIVE: PHONE:
PROJECT DESCRIPTION NEW SFR W/ATTACHED GARAGE
ALSO 120 GAL AG PROPANE TANK
TYPE OF WORK RES SQUARE FOOTAGE:
TYPE OF IMP NEW MAIN: 2,230
VALUATION 215,054.00 ADD'L: HEAT TYPE: EEE
CODE EDITION: 1997 HEAT BASE: HEAT TYPE: PRO
OCCUPANCY: R-3 UNHEATED: #OF STORIES: 1
OCCUPANCY: OTHER:
CONST TYPE: 5N SHORELINE:
GARAGE: 644
CONST TYPE: DECK: SETBACK: 118
BANK HEIGHT: 25
SEWAGE DISPOSAL: ALT
WATER SYSTEM: BRIDGEHVN PARCEL TAGS: YES NO
BEDROOMS: BATHROOMS: STORMWATER: YES NO AREA
Exist: Exist: Wetland Erosion
Prop: 2 Prop: 3 Seismic Streams
Total: 2 Total: 3 Flood Way Floodplain
F&W Landslide
Routing Date:
1(1 7e)(/ YShoreline Aquifer
Forest: Commercial Rural
Type Amount Paid By: Date: Receipt: A Fs,r outd t
Permit $1,643.35 KAS 06/30/04 66514 1 I::? D
Plan Check $1,068.18 KAS 06/30/04 66514 AUG 7 2L�4
State Building Code $4.50 KAS 06/30/04 66514
Potable Water Application $52.00 KAS 06/30/04 66514 Jefferson County Planning
Total: $2,768.03 &Building De artment
/ _ Bu
i [ /
# 1 . • ,.
_...› . —,•:—._
,,,
/ / ..e...:-
\ .
i/ •., / \
'N ..
••
.----1/ ' liatigt \•ji __,,‘ ' -. ____- • -•_
- 1 / ropirA ; 0- . 1,.„NT--.,H/\\, . ••
,c
1 *,
i . . .
, , ....,
Or ,
"
A
/
1 i [ (il....4. 0 , :1.:t.. l
1 I zi '
/ 0° ,
0 .t .,.
. 0
\ \
I / / kir
111011111.1411.// k
I MI IIIIM------.--,4•
Y 71
/ x
/ CI (
7----7<"
7--4
-,-
C.:
.. i I
.; •: "'• ,.. •• vl".7'..'. ' e/ . \
P. 111 ,11.
-I CD / 1 pla ... „r ,._. rr_ u, 17_,
in
a , / 1•3 \ i
II /I /7'
P1 \ I
:4
_ II
:I" usimmr---maimommisi
(/((//I/
/ Si / i I 1 I I •II 1 li.I II I II MI II
\ i ,
/
/ 0
1
I .6 (") 1 .•
1--4:,0
/
1 ; 0 I/
I !
X / 01 \
1 I /1 I
2 ;2 ,/ 1 / , \ x
/ Z
, 0
2
\
1 M i
il
/ •,
,/
/
,/
/ rn
m /
(48'
• Po
I r'..< /..//'
' gi I c.r)
01
CD
2
LC).7.,!•••,:\.3 .-_
. - - -
_ .
/1 r/ / tn / i Z
Iv rn
V) 1 ''--)' ---
1,/ - / cn 0 / R \ -
\ (/ /
rr,
z
,
\ \
i 1111 7
.-v \ \
/A1 i• -.1 I
\ 1
• Z 1 ' 1 _ I . 1 I
,-, ‘ \....
/ 7
\
0 \
i 1 \
\ 1 \
711! . • 1
i . / \
!
\
!
, r1 i 111 / ,./
' CI \ /
i 1 ; ,--
\
; 7 1)(
1
i
\ I 1
/ I
/ 111 /
\ - \
, s ,
/ al / \
/ .11 /
411 \ \ 1111111.11.111111111111111111111511ibb'' Cill \
/ ..1 i
15.1
El El Ill /
, / I
/ 1 9.4' "Illn.- 3, ,
1 El dliew 60' ---
t -
, i 1
11111 — /
,----------- - CI
‘ 14 . _ __-- „
: „Iv
cc)
. ,
1
4111
/
\
: /
, ,
1 i....._ 1 At.. ----
4._
<-)rr,
0-r -. . 0.
/
, 1 wto —4 1
_ _...1_ ' ------------ ... ____.
u)
a..., Ita ffil ____4 / 1
CO ___ --- _ ._ .. ,=== .:••,,'
- , 1 1 _ -6-7'.-4 -- _ \ . .
, _
rn 0-
------k---1---
,..: 1 _--
____--E-Ri ( 72_ •1 0;-0 0 rn __------ 4 •
1,-
, _ 0 w e")
...
_ ____---------- .
...---------------
M,CI Fril e
----------99Ar-----
T2, .
__________-r------ ______------ ",.:. ,c-7--, 4
----1--- -----______
-4. --z,----.---
r ,..
rnofil ,--------------______---- (—*------V/
--e------- ___.----------
------ ..,_ __----------
__,4---
,---------1--_
' ?--- --7--_—
.... Z.-
4) -----___
1- -A3- ------------
R________-----------
----.----------- `-t7
.......7.---,
-___ ________._...................m....._______
i
t 4. t g...e,
_ __-- -- -' 1 � . • elV� �,
a
,__A r___ ......- 8 i'°'
iiiiplik 4..c.
V� J
;; c i •
L\- n t� (rlIlr t
.\
....... • ,\R
.Iln ,
111 i
It" 642)CI IA i
Qwi
TMORNAYKE ROAO
•
•
, . ,ti
• .
I
•
/ SI
h 1� �• 2 0 x ±.—
n1• 1 Pi )$, '1,1 400° • ,b I ,'
f'-. 'Ts- 1 1 l• ::r3) - ' I . . : 1 .
• aA ,M ., b I�F s { I I' ' ti'
' , i _1 m I..• 1
r • f ; I � , .
l 1j
.. 11(,. • . . .
. I
.
•
(J
• 4101: ' • 1
a A__
n ..
p N
• 4 .
k� 3
83
C
70 • —_ I— a'. ...1
1 . •
Z'
0
1
n
WO
,/-- 1 _l .
\\ 4Ay
.....:\ •
\ 1
. 1
.
•
1
•
. • j
•
I
�. I P2.5O
tz 0 m a
o`� 2. m
II I_
A-► o = h
-ix o u
c L p Z 1 ^� •
r o u r
EITL do t
m m 4, o (". 1
•
. a App'1 1.
p.a•r , O • '0IL
I
1
1
I •
, , Jefferson County istinont of CommMty Development
4 621 Sheridan Street Port Townserxi WA ;�,�, (3Sill 378 44.50
i4,
pc�r��o APP�
�� p cC 0 C
Project Description:
Buildin. T ge e: a Pr
Fra
Single Famil Wood
Detached O Addition Steel
Most' "� Alteration/Remodel Concrete
Commercial :---
Repair Masonry
Multi-family/#of Units _� Demolition Other:
Industrial
Other: •
Bathrooms: Bedrooms: Type of Sewage Disposal: Type of Heat:
D Choose one:
Existing. Existing: Sewer CommunitySystem
Proposed: Ys ectricitv Oil
p 'S Proposed: 2 ndividual System_)
Total: 2•S Total: 2_ y Woodstove �Propane�
If not sewer,fill out the following: Heat Pump Conventional 41ZED Other W004&in, FP
Permit# SEP
Water Supply:
Private well Two Party Well Cblic�Name of water system: Shgdde ha ve.17 14/a er
Square Footage: For Office Use Only
Main Floor z 23 e I q9 -7‘1 90 Consistency Review Lig OD
2ND Floor Base fee lb' 7 3. 3s
3r Floor Plan Check fee /0 & /.9
Htd Basement State Surcharge fee 50
Unhtd Basement Subtotal 761! 03
Garage/Carport eo lig 15 179, 8 Pot Water Review fee O-:p-• 00
Decks ., 5/ r o R
, 9 1/Rd Approach fee EX�s M)O'% - Iai
Commercial :g I / /a TOTAL p �1J� 9. 03
Industrial ✓✓✓ Receipt# &0 S/C{
Other Cash/Check# (ZIS
Total Valuation: Initials
Or Date 07�/QV
Estimated Cost /(ra O 3 20 /
If within 200' of the Shoreline,
Distance to Bank or Ordinary High Water Mark Z✓5- ft.Bank Height PR' ft.
By signing the application form,the applicant/owner attests that the information provided herein is true and correct to the best of their knowledge. Any material falsehood or any
omission of a material fact made by the applicant/owner with respect to this application packet may result in this permit being null and void.
I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and expenses which may in any way accrue
against Jefferson County as a result of or in consequence of the granting of this permit.
I further agree to provide access and right of entry to Jefferson County and it's employees,representatives or agents for the purpose of application review and any required later inspections
Access and right of entry to the applicant's property or structure shall be requested and shall occur during regular business hours.
Signature:? 5Ykit/Me", LL C , .,,. . Date: 6,72 Vo�f
/ OVER ►
H:HOME\PLNCNTR\INFOBLDG\FORMS\BLDpemtitApplication 11-8-01
....., • 4111
.,*"V ,
3h nioarcencE moo
... --
/ / .�-r 261-- l�l :-.
20 ' i 20. r r
1' 1 1
�-216 , IA.�',
IV I //. 11 1
1 �/ /i PI
7/1
---- _
t
/ - am • ;: '
i 'ft1J7'
f, ' i ? _--
=1A bk0 1 ---
_J i , :,.5)61-,-c.- lel,!� .
itls.►i _ .adr .'
256
---} 250�fJ
�r
- yr 244
1
z38
—4 - 23'
��l 230
224
`-------220-
Ref: Site Plan and topography by'Malan Engineering, Inc.
SITE PLAN
Proposed Stelk Residence Project No. 04-257-oi
813 Thorndyke Road
Southpoint,Washington Drawing No. 1
Robert M.Pride,Inc. consulting Engineer
50' CONSTRUCTION APPROACH
1;-
FOLIND CONCRI-717 PLAT
MONUMENT `411TH 1; " BRASS
DISK, i' PELOI% RC/0 si /-FACE
FOUND 4-19-04�
i
NGVD 1929
10 0 10 .20
mmmll
Scale: 1 " = 10'
CONTOUR INTERVAL = 2'
EXISTING CONIFEROUS TREE
EXISTING TELEPHONE RISER
SET F DIA. RERAR, 24" LONG, WITH YELLOW
PIAWIC CAP lAfPI,'INI[ 01 t, +1.1 In" ANn
DROVE A 2"X2" WOOL) MARKO, WAN NCL�1f�,
UNLESS OTHERWISE NOTED.
FOUND PLAT MONUMENT AS NOTED.
/
/
R0P�
/E oo�0,�o
o 00o a0o a
o0900990-,0000 ��
���ov�&� 0.0( a two 0 a 0o
o 0o0 O O O ^O� O
�O �a� ��� T �o�O �� �c
o= t
/ o o a o On Oo ^ 0. 00
4" to 5" QUARRY SPALLS
-4S,
RFc FcQ'
gcRe aF op fop.
er s'� MAN
'DosFo/qcF
'To
vZ ass 4f
41, 6F
PROVIDE FULL WIDTH OF
INGRESS/EGRESS AREA
s w r
Ai Pii'
NOT TO SCALE
2 x2" WOOD —..
STAKE
FILTER FABRIC
RUNOFF WATER
WITH SEDIMENT —�
BURIED FILTER
FABRIC
NOTE:
SAND BAGS MAY BE USED IN PLACE OF FILTER FENCE
WHEN FILTER FABRIC IS IMPRACTICAL.
FLOW
STAKES
DR
WITH GRATE
NOT TO SCALE
MIRAFIC 100 NS
OR EQUIVALENT
MIRAFI 100 NS OR
EQUIVALENT FILTER
FABRIC MATERIAL
PROVIDE 3/4" - 1 1/2" WASHED
GRAVEL BACKFILL IN TRENCH AND
ON BOTH SIDES OF FILTER FENCE
FABRIC ON THE SURFACE
2" X 2' WOOD POST
OR STEEL FENCE POST
AT 6 FEET ON CENTER
� _:�:d 7777
i1 jp F�
JAN 13 2005
.JEFFERSON COUNTY
DEPT. OF COMMUNITY DEVELOPMENT
PROP. LINE
2' MIN.
NOT TO SCALE
z
0
o:
U
Z
C�
Z
�i
w
w
z
c�
z
w
Lu
Q
II
cc
LL
N
�k. WA
SyTyC�
-v
ONq� E�G�
EXP. DATE: 10 / 28
DATE: 7-30-04
SCALE: 1' 10'
JOB NO: 04017
FILE: 04017Sih Plan.dwp
STH
SHEET 4
OF 4 swiss