Loading...
HomeMy WebLinkAboutBLD2005-00098 ILDING PERMIT APPLICATN MLA05-00106 Review Type: Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD05-00098 Received Date: 2/22/2005 SITE ADDRESS: 42 VANCOUVER PL PORT TOWNSEND, 98368 OWNER: TIMOTHY L ADKINS PHONE: 360-379-0772 SUZANNE E ADKINS 42 VANCOUVER PL PORT TOWNSEND WA 98368-9445 SUBDIVISION: CAPE GEORGE COLONY DIV 3 Block: 5 Lot: 55 PARCEL NUMBER: 938400554 Section: 12 Township: 30 N Range: 02 W CONTRACTOR: OWNER/BUILDER PHONE: REPRESENTATIVE: PHONE: PROJECT DESCRIPTION EXISTING OUTBUILDING/PLAYHOUSE W/ COVERED PORCH TYPE OF WORK GAR SQUARE FOOTAGE: TYPE OF IMP NEW MAIN: 120 VALUATION ADD'L: HEAT TYPE: UH CODE EDITION: 2003 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: # OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: 216 SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: PARCEL TAGS: YES NO BEDROOMS: BATHROOMS: STORMWATER: YES NO AREA Exist: Exist: Wetland Erosion Prop: Prop: Seismic Streams Total: Total: Flood Way Floodplain Routing Date: F&W _ Landslide , I 1 Shoreline Aquifer Forest: Commercial Rural Type Amount Paid By: Date: Receipt: �ol l/�t� Permit $153.25 BAC 02/22/05 71511 A�pPP 1�'.jl UU t Plan Check $99.62 BAC 02/22/05 71511 State Building Code $4.50 BAC 02/22/05 71511 FEB 2 4 2005 Total: $257.37 Jefferson County Planning & Building Department r < _ -e1 I, • • BUILDING PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD05-00098 Received Date 02/22/2005 SITE ADDRESS: 42 VANCOUVER PL Issue Date 02/24/2005 PORT TOWNSEND, 98368 APPLICANT: TIMOTHY L ADKINS PHONE: 360-379-0772 SUZANNE E ADKINS 42 VANCOUVER PL PORT TOWNSEND WA 98368-9445 SUBDIVISION: CAPE GEORGE COLONY DIV 3 Block: 5 Lot: 55 PARCEL NUMBER: 938400554 Section: 12 Township: 30 N Range: 02 W CONTRACTOR: OWNER/BUILDER PHONE: PROJECT DESCRIPTION: EXISTING OUTBUILDING/PLAYHOUSE W/COVERED PORCH CALL IN FOR THE REQUIREQ INSPECTIONS THAT APPLY TO YOUR PROJECT. SETBACKS: N /t1 UFFER: N/ 1 Footing: N//4 Foundation:) Stormwater FINAL Approval: NJ Underground Plumbing: Underground Insulation: /N/A Shear Wall : giA Framing' Plumbing: n//,a Propane Tank/ Lines: NJ Insulation: Sheetrock: A//A- Septic Sytem Final Approval (If not on sewer): Road Approach Final Approval: Zan. Fin 1ApprQy • final/Occupancy Approva : 1 - HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. CALL 24 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. Office Hours 9:00 a.m. -4:30 p.m. HOT LINE AVAILABLE 24 HOURS A DAY SPECIAL CONDITIONS APPLY - SEE REVERSE • • SPECIAL CONDITIONS FOR CASE # BLD05-00098 1.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs)and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin. 2.) The project shall adhere to the Best Management Practices (BMPs)to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 3.) Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard. 4.) Not more than two (2) unlicensed or inoperable vehicles shall be stored on any lot less than one-half acre unless totally.screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Unified Development Code (UDC) Section 6. Outdoor storage of thirteen (13) or more unlicensed or inoperable vehicles is prohibited except in those districts where specified as an automobile wrecking yard or junk (or salvage)yard and allowed as a Permitted Use in Table 3-1 of the UDC, and such storage shall meet the requirements of UDC Section 4.10. In no case, shall any such unlicensed or inoperable vehiclesbe stored in an Environmentally Sensitive Area (ESA). 5.) Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc. 6.) The building height is not to exceed 35 feet. 7.) Minimum setback from Vancouver Place right-of-way shall be 20 feet. Minimum side and rear yard setbacks shall be 5 feet. If and ESA is present, then the more stricter setback shall apply. 8.) Exterior lighting for residential uses shall not exceed twenty feet(20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged. 9.) Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way. I:\F_BLD_Permit_Buildng.rpt 10/29/19 i _ _. 1 rt.._ • I 1 -1--_ [ 1 1 i , , I . _ a !_— _ ' !�CamI ' .. I ___ __________: • I ; , , , . ___ _. . , ,.._.„,.. s1 , �„ • , • • • . : - ,.. „.C. . ,,,,,t, r, ...t. , ..0zIr Ni F� r %' 4 /v ti ^ I ;I I I iT 4. t(,), :6) II v 1 ,--i. 0 �- `..� _ .— 1. i i ..., . • rt:11$ ____ r r • ... i ._ ... IMM. t �� .4 � � -,..-..0.4 iv, .:i . .... Eit -.---WN4 lk D if . if . -ri j ' 1.. '0 • I ra 1 - as 1 r, - ' 1 H ' • - r. t____ 01,___.6„._ i : 0 v 4 ', - Q . , i — - ; . -- -1 rs..4 V\ "ci ;si. ,,..... . ! ! 1 , _. : ► `• i; p �I -- } r 1 i 1,4 111 - - - . i.-. .,--, . ',„. 141 I i i � P '� - ra ti - 're':0 it >, 1 1 1_. w4.'�. 1 [ t i ' I, 1 . . . :.. - 4 —ram I ?..... I I i _ __ __. a It. - - -- __ I i kJ) 1 o ,. i , 1 a ' 1 �I®` ' i � ! ' j 'I °�' I 1 i i f I _ ! 14 4 ( 1 • T i��I If I _-___.1 -.------ ,! - --- _- r ; WI j ; cam , - I I 7 % .FF��MM • ...-.__..._-_ ..._ .___._._._. ' O __�.. _ ` ate ` ` _. i . . i 4 x d . 1 / . . r . ��gSox cO JEFFERSON COUNTY __ _ _ ` DEPARTMENT OF COMMUNITY DEVELOPMENT • 621 Sheridan Street • Port Townsend •V\lashintjton"98368 _. - i I 360/379-4450 • 360/379-4451 Fax , l l q$ G�0� www.co.jefferson.wa.us/commdevelopm`nt FEB 2 2 2005 s i Master Permit Application ' MLA: 05- ? n Project Description(include separate sheets as necessary): E i c; f it) JLA-ii-b,k.‘t 14 kws /62(.4w c1s, w i- . Co 0 .n rog_c_>w Tax Parcel 00 S 5 q Property / 3 Number: J Size: (acres/square feet) Site Address and/or Directions to Property: q). 041uc_6. k 0 ei it-c.z , j 4^ 'Ai 3_ Property Owner(s)of Record: /i t,1ti Wit- •. 4,+�� Aka{k r jv t Telephone: 5 1 ct - 0 Z Z 2 Fax: email:Ack-FAv v `I / F,7,y(e cl Mailing Address: 42 1, c C v�� PLi.t=-t Cv (--'t To LA.!N 5 e--1ti_c( WtW cL 'A&j 6 8 Applicant/Agent(if different from owner): Telephone: Fax: email: Mailing Address: What kind of Permit?(Check each box that applies) .,®.Building ❑Variance(Minor, Major or Reasonable Economic Use) ❑ Demolition Permit ❑ Conditional Use[C(a),C(d),or C]** 0 Single Family ❑ Discretionary"D"or Unnamed Use Classification ❑ Garage Attached/Detached ❑ Special Use(Essential Public Facilities)** ❑ Manufactured Home 0 Boundary Line Adjustment ❑ Modular ❑ Short Plat** ❑Commercial* ❑ Binding Site Plan** ❑Change of Use ❑ Long Plat** ❑Address ❑ Road Approach ❑ Planned Rural Residential Development(PRRD)/Amendments** 0 Propane ❑ Plat Vacation/Alteration** ❑Allowed"Yes"Use Consistency Analysis ❑ Shoreline Master Program Exemption/Permit Revisions** ❑Stormwater Management ❑ Shoreline Management Substantial Development** ❑ Site Plan Approval Advance Determination(SPAAD)* ❑ Shoreline Management Variance ❑Temporary Use ❑ Comprehensive Plan/UDC/Land Use District Map Amendment ❑Wireless Telecommunication* ❑Jefferson County Shoreline Master Program Amendment ❑ Forest Practices Act/Release of Six-Year Moratorium *May require a Pre—Application Conference **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: DESIGNATION OF AGENT I hereby designate to act as my agent in matters relating to this application for permit(s). OWNER SIGNATURE Date: By signing this application form,the owner/agent attests that the information provided herein,and in any attachments,is true and correct to the best of his,her or it's knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attomey's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and any r9quired later inspectio s.Access and right of entry to this property shall be requested and shall occur only during regular business :: z . - �d -- 5 — -- Date: �� Z-w The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential"take"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non-tranrable responr adhering to and complying with the ESA. The Applicant has read this disc mer and signs and dates it below. Signature.'its Date: -Z �-Z (G'ti G:\PermitCenter\FORMS\DRD FORMS\Master Perrplication 7-8-04.doc • OWNER BUILDER STATEMENT The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be assuring the reespo3sibil�General Contractor for the proposed project. Signatures ///ti.—, Cam / Date: ('Z 7-10 ,, GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX: ( ) ( ) MAILING ADDRESS: EMAIL: CONTRACTOR'S LICENSE WAINS NUMBER: NUMBER ARCHITECT/ENGINEER: C v v./1/41R-i_L'_5 R. Yyv i,�Iti j� / PHONE ('AGO ) 5 2-C, (t 6.FAX:(.' o ) 9 52 MAILING ADDRESS: .3 l CI S tec, ,�hoot_,1 ((y �/�6t-. /} ,�(.Qfj EMAIL Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal: ,A. New - Wood Existing: N4- ❑ Sewer ❑ Addition ❑ Steel Proposed: 2I4- Bank ❑ Community System ❑ Alteration/Remodel ❑ Concrete Total: Height ❑ Individual System ❑ Repair ❑ Masonry A SEP Permit# S€ rcf b 'a!y ❑ Demolition ❑ Other: brooms Water Supply: Existing: /.14- Setback: ❑ Private well 0 Two Party Type of Heat: Proposed: `A- ❑ Public Total: w Name of System: If this is a Commercial Proiect you must answer the following: Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants,employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: O Underground Tank ❑ Above ground Tank Size of Propane Tank: O Heat Stove 0 Cook Stove ❑ Woodstove ❑ Fireplace Insert ❑ Hot Water Tank 0 Pellet Stove 0 Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines,tank location and size,distances from the propane tank to all property lines,buildings and septic system components, including the reserve area. Square Footage For Of ice'`Use Only -,, ,- Current Proposed Amount Main Floor i,-. Consistency Review: 461 .) 6 ` GO f-1ii1-r�D 1.2 r� i0 9! ll "j L 2""Floor Base fee: t`J�J, a, 3`1 Floor Additional Section: �J�J' Mezzanine: Plan Check fee: ( 9 l ; (0Q Heated Basement ( State Surcharge fie: Unheated Basement Pot Water Revie i fee: Other Unheated FE B 9 li d�9�loach fee: Garage/Carport TOTAL: $ :06 Decks Receipt l 1 LO-v� 4 Other�p '`J (`C �� d � )1C Cash/Check Number la ) 4- ESTIMATED COST(REQUIRED) Date: tt •Fair market v_value of all labor and materials foundation to"finisi L 5 O00 ial�.5 rr al : G:\PernutCenter\FORMS\DRD FORMS\Master Pcrmi cation 7-8-04.doc1111 3/1" T4G PLYW 2X6 FLOOR JC AT 16" O.C. 4XI2 DF NO2 2x6 RAFTERS AT 24" O.C. (dOTICE: Plans are approved txcepling any errors or omisstons. All work must pass Inspection In conformance with all applicable codas and regulations. uFFER Roof= Roof= SCALE: 114" ■ 1'-0" ON - — 5CALE: 114" ■ P-O" 2XIO RAFTERS AT 24" O.C. DOUBLE 2XIO HIP TYPICAL COMP. ROOFING 30 LB BUIODING PAPER 2X6 RAFTERS AT 24" O.C. COMP. ROOFING 30 LB BUIODING PAPER 2XIO RAFTERS AT 24" O.C. COMP. ROOFING 30 LB BUIODING PAPER 2X6 RAFTERS AT 24" O.C. SIDING OVER BUILDING PAPER 1/2" EXTERIOR SHEETING 2X4 STUDS AT 16" O.C. 12" DIA. CONCRETE PLINTH WITH SIMPSON C55066-SDS2 BASE AND 6X6 POST TYPICAL FOR (1) 2'-0" X 1'-0" X 18" DEEP CONCRETE FOOTING WITH (2) NOA BARS EACH WAY TYPICAL FOR (1) 2Xb RAFTERS AT 24" O.C. TYPICAL 1„IIDE)LE ROOF SCALE: 1/4" ■ 1'-0" XI2 1402 i s M# nN- 4 'f A C. t 1 orgy FLOOfR FLAN SCALE: 1/4" ■ 1'-0" 4X4 KNEE BRACES 12" DIA. CONCRETE PLINTH AT BAY WINDOW 14" O.C. lul'r1 ii c h'F t."gym diC'iV-:71JJL PROVIDE 2X SOLID BLOCKING BASE AND 6Xb POST AT FLOOR JOISTS AS SHOWN 15'-C411 TYPICAL FOR (1) 4'-0" i 18'-b" 1 1/2" 1' 4" 2'-0" X 2'-0" X 18" DEEP 2X6 FLOOR JOISTS CONCRETE FOOTING WITH AT 16" O.C.0 TYPICAL (2) NOA BARS EACH WAY TYPICAL FOR (1) 04 DF P102 v J �.1 I -It iA 2 1 1 S- I I o� COntadt the Building Department F n k Changes at 379-�5n q x XI 1 1 II I r- - ■ r I L1J I t ■ 0 r i Ir11 DU DCD PROVIDE 2X4 POST L J I L J L I L_ -.-.N RIVIEW FROM COLLAR TIE TO UPPER BEAM ❑ AI- ,iC " . ^ SUBMaM Y 2'-O" X 1'-0" X 10" DEEP . APPROVED iS NOTED 131,411 10'-1 1/2" 1 4" CONCRETE FOOTING WITH 4, -O "„ -4 „ El REJECTED 10 -5 (2) NOA BARS EACH WAY le 15'-.)" TYPICAL FOR (3) Date, A/y/O,',� Reviewer L ouiE f' fROOF SCALE: 114" = 1'-0" FOUNDATION FLAN SCALE: 114" ■ I'-O" FEB 2 2 200 9 N fs0, 0 � a b �'a N C) O N � z ._� r � owl N'< J Y C 3 u I T H r z II�Ht A a 0 tQ 4i co co to o I I CO -. v 0 0 a rn 4 CO CO a CD o w 1-4a° - FILE copY -