HomeMy WebLinkAbout35_Site Lighting Plan _2024-0314PLAN 1 PLAN 2 PLAN 3 PLAN 5 PLAN 4 PLAN 6 PLAN 7 SEE 1 E2.1 SEE 1 E2.4 SEE 1 E2.2 SEE 1 E2.5 SEE 1 E2.3 SEE 1 E2.6 SEE 1 E2.7 ROAD A-1 PATH-P3 TO P7ROAD EROAD DP2 ROAD A-2PATH P2-EPATH-P2 TO P4ROAD B-1ROAD B-2ROAD A-3ROAD C-1R O A D A -4 ROAD A-5R O A D A -6ROAD FROAD A-7 ROAD G ROAD C-2ROAD C-3PATH P10 TO P12R O A D H ROAD B-2PATH -P5 E PATH -P5 TO P3 PATH-P5 TO P4P A T H- P 4 E LIGHTING EM SURFACE MOUNTE LIGHT FIXTURE RECESSED LIGHT FIXTURE RECESSED LIGHT FIXTURE WITH END PLATES SURFACE MOUNTED STRIP LIGHT FIXTURE UNDER CABINET/VALENCE STRIP LIGHT FIXTURE WALL MOUNTED CUBED LIGHT FIXTURE SURFACE MOUNTED LIGHT FIXTURE RECESSED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE WALL MOUNTED LIGHT FIXTURE ON EMERGENCY TRACK LIGHT C/W PENDANT HEADS TRACK LIGHT C/W ADJUSTABLE HEADS BOLLARD LIGHT FIXTURE POLE MOUNTED LIGHT FIXTURE (ONE HEAD SHOWN) LANDSCAPE UPLIGHT FIXTURE RECESSED STEP LIGHT FIXTURE SURFACE MOUNTED HOT TUB/POOL LIGHT FIXTURE SWITCHES AND JUNCTION BOXES SLINE VOLTAGE SWITCH SSWITCH C/W PILOT LIGHTP STWO POLE SWITCH2 STHREE WAY SWITCH3 SFOUR WAY SWITCH4 SMANUAL MOTOR PROTECTION SWITCH C/W PILOT LIGHTM SKEY OPERATED SWITCH - CYLINDER TYPE K STIMER SWITCHT SDIMMER SWITCH - SILDER TYPE D SINTERNALLY ILLUMINATED LIGHT SWITCHL SLOW VOLTAGE SWITCHR 2 GANG SWITCH 3 GANG SWITCH 4 GANG SWITCH 5 GANG SWITCH WALL MOUNTED PHOTOCELL J J WALL MOUNTED JUNCTION BOX J FLOOR MOUNTED JUNCTION BOX CEILING MOUNTED JUNCTION BOX T THERMOSTAT NON-FUSEABLE DISCONNECT SWITCH FUSEABLE DISCONNECT SWITCH COMBINATION MAGNETIC HOA STARTER O/H DOOR PUSH BUTTON PB PULL BOX RC DIMMING ROOM CONTROLLER PP POWER PACK BARRIER FREE PUSHBUTTONBF MISCELLANEOUS AND LABELS -FIXTURE TYPE -REVISION NUMBER --MECHANICAL EQUIPMENT IDENTIFICATION TAG --KITCHEN EQUIPMENT TAG --KEY NOTES SINGLE LINE BREAK DOUBLE LINE BREAK CAPPED OFF LINE OR CONDUIT CONDUIT BREAK CABLE TRAY NIGHT LIGHTNL TAMPER PROOFTP GROUND FAULT CIRCUIT INTERRUPTERGFCI ISOLATED GROUNDIG EMERGENCYEM AMP FRAMEAF AMP TRIPAT WEATHER PROOFWP EXPLOSION PROOFXP EXISTING DEVICE TO REMAINE EXISTING DEVICE TO BE REMOVEDX EXISTING DEVICE TO BE RELOCATEDER RELOCATED DEVICERD WIRE COUNT CONDUIT RUN UP CONDUIT RUN DOWN UNDERGROUND CONDUCTOR/CONDUIT FLEXIBLE CONDUIT EXISTING EQUIPMENT NEW EQUIPMENT EQUIPMENT TO BE REMOVED Reference Drawing List SHEET NUMBER SHEET NAME DISCIPLINE DESIGNED BY DRAWN BY DISCIPLINE ORDER E1.1 OVERALL SITE LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E1.2 NOTES AND DETAILS ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.1 PLAN 1 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.2 PLAN 2 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.3 PLAN 3 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.4 PLAN 4 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.5 PLAN 5 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.6 PLAN 6 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 E2.7 PLAN 7 LIGHTING ELECTRICAL M.P.L.,N.O.W.M.P.L.,N.O.W.7 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/14/24 1248-001PROJECT NAMEE1.1 OVERALL SITE LIGHTING 1" = 200'-0" SITE LIGHTING PLAN NAME: PLEASANT HARBOR RESORT -PLAT SITE LIGHTING ADDRESS: 308913 US0191, BRINNON, WA 98320 NTS LIGHTING LEGENDDRAFT Exhibit 35 DIVISION 26.00.10 ELECTRICAL GENERAL REQUIREMENTS REGULATORY REQUIREMENTS 1. COMPLY WITH SAFETY CODES ACT AND RULES AND REGULATIONS MADE PURSUANT THERETO, INCLUDING THE CANADIAN ELECTRICAL CODE. 2. ELECTRICAL PRODUCTS SHALL BE TESTED, CERTIFIED AND LABELED IN ACCORDANCE WITH A CERTIFICATION PROGRAM ACCREDITED BY THE STANDARDS COUNCIL OF CANADA. WHERE A PRODUCT IS NOT SO LABELED, PROVIDE WRITTEN APPROVAL BY THE AUTHORITY HAVING JURISDICTION. 3. SUBMIT TO AUTHORITY HAVING JURISDICTION, NECESSARY NUMBER OF DRAWINGS AND SPECIFICATIONS FOR EXAMINATION AND APPROVAL PRIOR TO COMMENCEMENT OF ELECTRICAL WORK. PAY ASSOCIATED FEES. PROVIDE COMPLETE, FULLY TESTED, AND OPERATIONAL MECHANICAL SYSTEMS TO MEET REQUIREMENTS DESCRIBED HEREIN AND INCOMPLETE ACCORD WITH APPLICABLE AND CURRENT CODES AND ORDINANCES. SHOP DRAWINGS 1. SUBMIT LIST OF PRODUCTS INCLUDING MANUFACTURER AND FULL MODEL NUMBER PRIOR TO PURCHASE. FIRE BARRIERS 1. ALL PENETRATIONS OF FIRE SEPARATION BARRIERS MUST BE SEALED TO BUILDING CODE STANDARDS. CLEANING 1. PRIOR TO INTERIM ACCEPTANCE OF WORK, REMOVE ALL CONSTRUCTION DUST AND DEBRIS AND CLEAN OUT ALL CABINETS AND ENCLOSURES WITH VACUUM AND/OR COMPRESSED AIR. OPERATION AND MAINTENANCE DATA 1. PROVIDE THE FOLLOWING FOR ALL SYSTEMS AND COMPONENTS: 1. MANUFACTURE'S PRODUCT DATA, INCLUDING PERFORMANCE 2. CURVES AND SCHEMATIC AND WIRING DIAGRAMS FOR ALL ELECTRICAL CONTROL SYSTEMS. 3. MANUFACTURER'S INSTALLATION INSTRUCTIONS. 4. MANUFACTURER'S MAINTENANCE INSTRUCTIONS INCLUDING COMPLETE PARTS LIST FOR ALL SERVICEABLE COMPONENTS. 2. PROVIDE A COMPREHENSIVE LIST OF SUBCONTRACTORS, SUB- SUBCONTRACTORS AND SUPPLIERS WHO SUPPLIED AND INSTALLED SYSTEMS AND COMPONENTS. 3. PROVIDE COPIES OF ALL INSPECTION CERTIFICATION REPORTS FROM AUTHORITIES HAVING JURISDICTION. RECORD DRAWINGS 1. RECORD ACTUAL LOCATIONS OF ALL PULL BOXES, PANELBOARDS, LUMINARIES, FEEDERS, ELECTRICAL EQUIPMENT AND ELECTRICAL SITE SERVICES. 2. RECORD ANY CHANGES TO CIRCUIT DESIGNATIONS. COORDINATION 1. COORDINATE WORK SPECIFIED IN DIVISION 16 WITH WORK SPECIFIED IN OTHER DIVISIONS. ENSURE THAT PROPER ARRANGEMENTS AND PROVISIONS ARE MADE FOR WORK SPECIFIED IN DIVISION 16. ELECTRICAL IDENTIFICATION 1. ELECTRICAL EQUIPMENT SHALL BE COLOUR CODED AS FOLLOWS: 1. 120/208V OR 120/240V LINE VOLTAGE EQUIPMENT: GREY 2. FIRE ALARM SYSTEM EQUIPMENT: RED 3. TELEPHONE CABINETS: GREEN 2. PANELBOARD DIRECTORIES: IDENTIFY LOADS CONTROLLED BY EACH OVERCURRENT PROTECTIVE DEVICE IN EACH PANELBOARD, BY MEANS OF A TYPEWRITTEN PANELBOARD DIRECTORY. DIVISION 26.05.33 BOXES AND FITTINGS GENERAL 1. LOCATION OF OUTLET BOXES ARE SHOWN SCHEMATICALLY ON DRAWINGS AND ARE APPROXIMATE UNLESS OTHERWISE NOTED. VERIFY ALL LOCATIONS PRIOR TO ROUGH-IN. 2. CONFIRM SIZE AND LOCATION OF EQUIPMENT SUPPLIED AND INSTALLED UNDER OTHER SECTIONS, PRIOR TO ROUGH IN. 3. ALL MOUNTING HEIGHTS ARE MEASURED FROM FINISHED FLOOR TO CENTRE LINE OF DEVICE. 4. OWNER RESERVES THE RIGHT TO CHANGE LOCATION OF OUTLETS WITHIN 3m OF INDICATED LOCATION PRIOR TO INSTALLATION WITH NO CHANGE IN CONTRACT PRICE. PRODUCTS EXECUTION 1. DO NOT INSTALL BOXES BACK TO BACK. ALLOW MINIMUM: 1. 150mm SEPARATION IN CONVENTIONAL WALLS. 2. 600mm SEPARATION IN ACOUSTIC RATED WALLS. 2. POSITION BOXES ON MASONRY WALLS TO SUIT MASONRY COURSE LINES. 3. MOUNT BOXES AT FOLLOWING HEIGHTS: 1. LOCAL SWITCHES:1050mm 2. RECEPTACLES: 3. GENERAL:300mm 4. ABOVE COUNTERS:150mm + COUNTER 5. ABOVE BASEBOARD HEATERS:200mm ABOVE (MIN.) 6. UTILITY/MECHANICAL ROOMS:1050mm 7. EXISTING AREAS:MATCH EXISTING DIVISION 26.05.13 MEDIUM VOLTAGE CABLES GENERAL 1. SIZE AND CONFIGURATION OF WIRING AS INDICATED ON DRAWINGS OR AS REQUIRED BY CEC. 2. USE ONLY WIRE SUITABLE FOR INTENDED APPLICATION. 3. ALL CONDUCTORS TO BE COPPER UNLESS NOTED OTHERWISE. PRODUCTS 1. BUILDING WIRE: 1. TYPES: RW90 2. SOLID OR STRANDED, STRANDED FOR CONNECTION TO MOTORS OR WHERE FLEXIBLE CONNECTION IS REQUIRED. 3. FOR LOW AMBIENT TEMPERATURE OR UNDERGROUND APPLICATIONS PROVIDE CABLE WITH SUITABLE ADDITIONAL RATINGS. 4. USE 1000V INSULATION FOR SYSTEMS GREATER THAN 300V RMS LINE TO LINE. 5. USES: GENERAL PURPOSE USE, IN CONDUIT. 2. ARMOURED CABLE (BX): 1. TYPES: AC-90 2. USES: FINAL CONNECTION TO LUMINARIES IN T-BAR CEILINGS, 1.5m MAXIMUM LENGTH. 3. NON-METALLIC SHEATHED CABLE: 1. TYPES: NMD-90 2. USES: RESIDENTIAL SUITES 4. CONTROL CABLE FOR CLASS 2 REMOTE CIRCUITS 1. TYPE: 300V, INDIVIDUAL CONDUCTORS TWISTED TOGETHER, SHIELDED WHERE INDICATED. 2. USES: REMOTE CONTROL AND SIGNAL CIRCUITS 5. ARMOURED CABLE (TECK). 1. TYPE: TECK90 2. USES: WHERE INDICATED ON DRAWINGS EXECUTION 1. SPLICE WIRING ONLY IN JUNCTION OR OUTLET BOXES. DO NOT SPLICE WIRING IN INACCESSIBLE SPACES. INSTALLATION OF ACCESS DOORS WITHOUT PRIOR APPROVAL IS NOT ACCEPTABLE. 2. NEATLY TRAIN AND LACE CONDUCTORS INSIDE CABINETS, EQUIPMENT AND PANELBOARDS. 3. SWAB RACEWAY SYSTEM BEFORE INSTALLING WIRING 4. MINIMUM WIRE SIZES AS FOLLOWS: 1. LIGHTING CIRCUITS: 12 AWG 2. POWER CIRCUITS: 12 AWG 3. MOTOR CIRCUITS: 12 AWG 4. FEEDERS:AS INDICATED ON DRAWINGS 5. FIRE ALARM: 1. INITIATING CIRCUITS 14 AWG 2. ANNUNCIATING CIRCUITS 12 AWG 3. AUXILIARY EQUIPMENT 14 AWG DIVISION 26.05.34 CONDUIT PRODUCTS 1. RIGID METAL CONDUIT: TO CSA C22.2 No. 45.1-07 (R2017), AND AS FOLLOWS: 1. GALVANIZED RIGID STEEL CONDUIT: ZINC COATED STEEL. 2. PVC EXTERNALLY COATED RIGID STEEL CONDUIT: ZINC COATED STEEL WITH ADDITIONAL EXTERNAL COATING OF PVC. 3. EPOXY COATED RIGID STEEL CONDUIT: ZINC COATED STEEL, WITH ADDITIONAL EPOXY COATING INSIDE AND OUTSIDE. 4. RIGID ALUMINUM CONDUIT: WITH FACTORY APPLIED, CLOSED-END THREAD PROTECTORS. 5. FITTINGS: SAME MATERIAL AS CONDUIT. 2. ELECTRICAL METALLIC TUBING (EMT): TO CSA C22.2 No. 83-M1985 (R2017), WITH FITTINGS AS FOLLOWS: 1. FITTING MATERIAL FOR 25mm SIZE CONDUIT AND SMALLER: ZINC ALLOY OR ZINC COATED STEEL. 2. FITTING MATERIAL FOR CONDUIT LARGER THAN 25mm SIZE: ZINC COATED STEEL. 3. TYPE: COMPRESSION OR SET SCREW, LIQUID TIGHT FOR WET OR DAMP AREAS. 3. FLEXIBLE METAL CONDUIT: TO CSA C22.2 No. 56-17, AND AS FOLLOWS: 1. FLEXIBLE METAL CONDUIT: SPIRALLY WOUND, INTERLOCKED ZINC COATED STRIP STEEL, MINIMUM 10mm DIAMETER. 2. FLEXIBLE METAL CONDUIT FITTINGS: THREADLESS HINGED CLAMP TYPE. 3. LIQUID-TIGHT FLEXIBLE METAL CONDUIT: CONTINUOUS INTERLOCKED AND DOUBLE WRAPPED STEEL, ZINC COATED INSIDE AND OUTSIDE, COATED WITH LIQUID-TIGHT JACKET OF FLEXIBLE PVC, MINIMUM 12mm DIAMETER. LIQUID-TIGHT. 4. FLEXIBLE METAL CONDUIT FITTINGS: CADMIUM PLATED, MALLEABLE IRON FITTINGS WITH COMPRESSION TYPE STEEL FERRULE AND NEOPRENE GASKET SEALING RINGS. 4. NON-METALLIC CONDUIT: 1. RIGID TYPE EB1 PVC CONDUIT: TO CSA C22.2 No. 211.1-06 (R2011). (SPECIFY TYPE EB1 FOR ENCASEMENT IN CONCRETE OR MASONRY ONLY). 2. RIGID TYPE DB2/ES2 PVC CONDUIT: TO CSA C22.2 No. 211.1-06 (R2011). (SPECIFY TYPE DB2/ES2 FOR DIRECT BURIAL OR ENCASEMENT IN CONCRETE OR MASONRY). 3. RIGID PVC (UNPLASTICIZED) CONDUIT: TO CSA C22.2 No. 211.2- 06 (R2011). DIVISION 26.05.34 CONDUIT -CONTINUED 4. REINFORCED THERMOSETTING RESIN CONDUIT(RTRC) AND FITTINGS: TO CSA C22.2 No. 2420-09. 5. MISCELLANEOUS FITTINGS: LOCKNUTS, BUSHINGS, REDUCERS, CHASE NIPPLES, 3 PIECE UNIONS, SPLIT COUPLINGS, PLUGS, AND EXPANSION FITTINGS SPECIFICALLY DESIGNED FOR THEIR PARTICULAR APPLICATION. INSTALLATION - GENERAL 1. WHERE REQUIRED TO BE CONCEALED, INSTALL CONDUIT NEATLY AND CLOSE TO BUILDING STRUCTURE SO AS TO MINIMIZE NEED FOR FURRING. 2. INSTALLED CONDUIT SHALL BE FREE FROM DENTS, BRUISES AND OTHER DAMAGE. 3. PLUG CONDUIT ENDS TO PREVENT ENTRY OF DIRT AND MOISTURE. 4. SEAL CONDUIT WITH DUCT SEAL COMPOUND OR FIBREGLASS WHERE CONDUIT LEAVES HEATED AREA AND ENTERS UNHEATED AREA. 5. PROVIDE NECESSARY FLASHING AND PITCH POCKETS, MAKING WATERTIGHT JOINTS WHERE CONDUIT PASSES THROUGH ROOF OR WATERPROOFING MEMBRANES. 6. WHERE CONDUIT CROSSES BUILDING EXPANSION JOINTS, INSTALL EXPANSION FITTING APPROVED BY AUTHORITY HAVING JURISDICTION, COMPLETE WITH GROUNDING JUMPER. PROVIDE BEND OR OFFSET IN CONDUIT ADJACENT TO BUILDING EXPANSION JOINT WHERE CONDUIT IS INSTALLED ABOVE SUSPENDED CEILINGS. 7. PROVIDE RAIN-TIGHT FITTINGS IN WEATHERPROOF AND DAMP AREAS. INSTALLATION OF NON-METALLIC CONDUIT 1. MAKE FIELD BENDS AND SOLVENT CEMENTED JOINTS IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS INSTALLATION OF EXPOSED AND SEMI-CONCEALED CONDUIT 1. COMPLY WITH THE FOLLOWING WHEN INSTALLING CONDUIT EXPOSED IN SERVICE AREAS, AND IN ACCESSIBLE AREAS BEHIND CEILINGS, WALLS AND FLOORS: 1. INSTALL CONDUIT TO CONSERVE HEADROOM AND CAUSE MINIMUM INTERFERENCE IN SPACES THROUGH WHICH CONDUIT PASSES. 2. INSTALL CONDUIT SO AS NOT TO INTERFERE WITH CEILING INSERTS, LUMINARIES OR VENTILATION DUCTS OR OUTLETS. 3. ALTER ROUTING TO AVOID STRUCTURAL OBSTRUCTIONS, KEEPING CROSSOVERS TO A MINIMUM. 4. INSTALL EXPOSED CONDUIT AND EXTENSIONS FROM CONCEALED CONDUIT SYSTEMS NEATLY, PARALLEL WITH, OR AT RIGHT ANGLES TO WALLS AND STRUCTURAL MEMBERS. 5. RUN CONDUIT FOR OUTLETS ON WATERPROOF WALLS EXPOSED. SET ANCHORS FOR SUPPORTING CONDUIT ON WATERPROOF WALL IN WATERPROOF CEMENT. 6. WHERE PRACTICABLE, INSTALL CONDUIT CONCEALED IN WALLS, FLOORS, CEILINGS AND ABOVE SUSPENDED CEILING AND UNDERGROUND. DIVISION 26.50.20 LIGHTING GENERAL 1. COORDINATE INSTALLATION OF LUMINARIES WITH ARCHITECTURAL DETAILS, REFLECTED CEILING PLAN AND MECHANICAL EQUIPMENT. 2. ENSURE INSTALLED LUMINARIES ARE ACCESSIBLE FOR SERVICING AND REPLACEMENT PRODUCTS 1. PROVIDE TYPE AND QUANTITY OF FIXTURES INDICATED ON DRAWINGS. 2. PROVIDE ALL MOUNTING HARDWARE AND SUPPORTS TO PROPERLY SUPPORT FIXTURES. 3. PROVIDE TRIMS, BEZELS, ETC. AS REQUIRED TO FINISH TO ADJOINING SURFACES. EXECUTION 1. ALIGN AND/OR CENTER FIXTURES WHERE APPLICABLE TO PROVIDE NEAT APPEARANCE. CONFIRM LOCATION AND MOUNTING HEIGHT OF FIXTURES WITH OWNER'S REPRESENTATIVE PRIOR TO INSTALLATION. 2. PRIOR TO INTERIM ACCEPTANCE OF THE WORK: 1. CLEAN ALL LUMINARIES TO REMOVE CONSTRUCTION DUST AND DEBRIS. REMOVE PROTECTIVE FILMS. 2. ADJUST OR PROGRAM ALL ADJUSTABLE SETTINGS AS DIRECTED BY OWNER'S REPRESENTATIVE. Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/14/24 1248-001PROJECT NAMEE1.2 NOTES AND DETAILS LUMINARIE SCHEDULE TYPE DESCRIPTION MANUFACTURER MODEL VOLTAGE WATTAGE LUMEN LAMP TYPE COLOUR TEMP. MOUNTING REMARKS A ROADWAY LIGHT STANDARD COOPER GAN-SA3A-830-U-T3R 120 V 275 W 30617 lm LED 3000 K POLE 35' POLE - 5' SETBACK B PATHWAY LIGHT STANDARD COOPER GAN-SA1B-830-U-SL3 120 V 94 W 10991 lm LED 3000 K POLE 12' POLE - 2' SETBACK LIGHTING CALCULATIONS Calculation Points Name AVERAGE MAXIMUM MINIMUM AVG/MIN MAX/MIN PATH - P2 EAST 1.59 fc 7.84 fc 0.08 fc 20.6 101.5 PATH - P2 EAST INTERSECTION 1.50 fc 5.59 fc 0.01 fc 215.4 801.8 PATH - P3 TO P5 1.43 fc 7.45 fc 0.01 fc 155.2 809.0 PATH - P3 TO P7 1.56 fc 8.24 fc 0.02 fc 79.9 423.3 PATH - P4 EAST 1.59 fc 7.64 fc 0.06 fc 24.7 119.0 PATH - P4 EAST INTERSECTION 2.19 fc 7.25 fc 0.07 fc 33.6 111.0 PATH - P4 NORTH 1.59 fc 7.58 fc 0.04 fc 35.5 169.1 PATH - P4 NORTH INTERSECTION 3.31 fc 7.95 fc 1.40 fc 2.4 5.7 PATH - P4 TO P2 EAST 1.54 fc 8.24 fc 0.06 fc 26.4 141.2 PATH - P5 SE 1.43 fc 8.22 fc 0.00 fc 1236.3 7105.3 PATH - P5 SOUTH INTERSECTION 1.20 fc 8.09 fc 0.03 fc 46.5 312.4 PATH - P5 TO P4 1.49 fc 7.86 fc 0.03 fc 57.1 300.3 PATH - P10 TO P12 EAST 1.52 fc 7.77 fc 0.01 fc 150.8 770.4 Road A - 1 0.71 fc 1.68 fc 0.15 fc 4.8 11.2 Road A - 2 0.71 fc 1.66 fc 0.21 fc 3.4 7.9 Road A - 3 0.96 fc 1.73 fc 0.45 fc 2.1 3.8 Road A - 4 0.80 fc 1.71 fc 0.21 fc 3.8 8.2 Road A - 5 0.92 fc 1.70 fc 0.42 fc 2.2 4.1 Road A - 6 0.71 fc 1.66 fc 0.16 fc 4.5 10.6 Road A - 7 0.85 fc 1.70 fc 0.20 fc 4.3 8.7 Road A and B Intersection 2.06 fc 2.70 fc 1.43 fc 1.4 1.9 Road A and C Intersection - 2 1.84 fc 2.51 fc 1.23 fc 1.5 2.0 Road A and C Intersection - 1 2.04 fc 2.57 fc 1.49 fc 1.4 1.7 Road A and E Intersection 1.93 fc 2.52 fc 1.31 fc 1.5 1.9 Road A and F Intersection 2.11 fc 3.12 fc 1.36 fc 1.5 2.3 Road A and G Intersection 2.08 fc 2.76 fc 1.49 fc 1.4 1.9 Road A,B, and D Intersection 1.84 fc 2.65 fc 0.87 fc 2.1 3.0 Road B - 1 0.74 fc 1.76 fc 0.10 fc 7.1 16.8 Road B - 2 0.71 fc 1.66 fc 0.16 fc 4.5 10.5 Road B and H Intersection 2.08 fc 2.74 fc 1.44 fc 1.4 1.9 Road C - 1 0.75 fc 1.90 fc 0.11 fc 6.9 17.5 Road C - 2 1.58 fc 2.05 fc 1.10 fc 1.4 1.9 Road C - 3 0.71 fc 1.65 fc 0.09 fc 7.7 17.9 Road C and G Intersection 2.16 fc 2.81 fc 1.55 fc 1.4 1.8 Road E 0.73 fc 1.66 fc 0.06 fc 11.7 26.6 Road F 0.84 fc 1.75 fc 0.21 fc 4.1 8.5 Road G 0.88 fc 1.72 fc 0.29 fc 3.0 5.9 Road H 0.69 fc 1.66 fc 0.06 fc 12.3 29.7 SITE LIGHTING INTENT AND DESCRIPTION: THE INTENT AT THE PLEASANT HARBOR RESORT IS TO PROVIDE NIGHT SKY FRIENDLY SITE LIGHTING THAT CAN EFFECTIVELY BALANCE THE NEED FOR SAFETY AND FUNCTIONALITY. THE LIGHTING LAYOUT AND DESIGN WILL PRESERVE THE NATURAL NIGHT SKY, IN ACCORDANCE WITH DARK SKY ASSOCIATION (IDC) STANDARDS AND PRINCIPALS OF SUSTAINABLE DEVELOPMENT BY FOCUSING ON THE FOLLOWING KEY ELEMENTS: •MINIMIZING LIGHT POLLUTION BY USING DOWNWARD DIRECTED FIXTURES. •PRESERVING VISIBILITY OF THE NATURAL NIGHT SKY. •ENSURING SAFETY AND SECURITY WITH APPROPRIATE ILLUMINATION. •SELECTING DARK SKY FRIENDLY FIXTURES COMPLIANT WITH IDA STANDARDS. •ADHERING TO LOCAL REGULATIONS AND GUIDELINES. •INTEGRATING LIGHTING SEAMLESSLY WITH ARCHITECTURAL AND LANDSCAPE DESIGN. •PRIORITIZING SUSTAINABILITY AND ENERGY EFFICIENCY WITH THE USE OF LED TECHNOLOGY. THE LIGHTING DESIGN WILL ALSO FOLLOW THE WASHINGTON STATE DEPARTMENT OF TRANSPORTATION - DESIGN GUIDELINES FOR ROADWAY ILLUMINATION. THE ROADS ON THIS DEVELOPMENT ARE CONSIDERED MINOR ROADWAYS WITH LOW ACTIVITY (ANSI/IES RP-8 LOW PEDESTRIAN CONFLICT AREA -AREAS IN WHICH 10 OR FEWER PEDESTRIANS CROSS AT NIGHT OVER A 1HR PERIOD). CONTROL PHILOSOPHY AND BASIS OF DESIGN •FIXTURES TO HAVE 7-PIN CONFIGURATION. •OUTDOOR CONTROL PATFORM OPERATES ON A WIRELESS MESH NETWORK BASED ON IEEE 802.15.4 STANDARDS ENABLING WIRELESS CONTROL OF OUTDOOR LIGHTING. •OUTDOOR CONTROL MODULE CONTAINS PHOTOCONTROL THAT ENABLES ASTRONOMIC OR TIME-BASED SCHEDULES TO PROVIDE ON/OFF AND DIMMING CONTROL OF FIXTURES UTILIZING A 7-PIN RECEPTACLE. •FIXTURES CONTAIN WIRELESS SENSOR: •SENSORS OFFER PASSIVE INFRARED (PIR) OCCUPANCY SENSING AND A PHOTOCELL FOR CLOSED-LOOP DAYLIGHT SENSING. THE SENSORS ARE FACTORY PRESET TO DIM DOWN TO APPROXIMATELY 50% POWER AFTER 15 MINUTES OF NO ACTIVITY DETECTED, AND THE PHOTOCELL FOR DUSK-TO-DAWN CONTROL IS DEFAULT ENABLED. A VARIETY OF SENSOR LENSES ARE AVAILABLE TO OPTIMIZE THE COVERAGE PATTERN FOR MOUNTING HEIGHTS 7'-40'. DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.1 PLAN 1 LIGHTING 1" = 50'-0"E1.1 PLAN 1 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.2 PLAN 2 LIGHTING 1" = 50'-0"E1.1 PLAN 2 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.3 PLAN 3 LIGHTING 1" = 50'-0"E1.1 PLAN 3 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.4 PLAN 4 LIGHTING 1" = 50'-0"E1.1 PLAN 4 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.5 PLAN 5 LIGHTING 1" = 50'-0"E1.1 PLAN 5 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.6 PLAN 6 LIGHTING 1" = 50'-0"E1.1 PLAN 6 LIGHTING 1 DRAFT Exhibit 35 Drawing Title: Date: Project No:Version: Issued: Consultant:Project Address:City Posse Number:DISCLAIMER: THIS DRAWING IS COPYRIGHTED AND MUST NOT BE USED,REPRODUCED, OR REVISED WITHOUT WRITTEN PERMISSION. DO NOT SCALE THIS DRAWING. REPORT INCONSISTENCIES AND OMISSIONS TO CONSULTANT BEFORE COMMENCING WORK. THESE DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL SEALED OR ADVISED IN WRITING BY THE CONSULTANT. THIS DRAWING SUPERSEDES PREVIOUS ISSUES. 9834-105 Street Edmonton, AB T5K 1A6 Office: (780) 423-3424 Drawing No: Client: P R O G R E S S S E T 7370 Sierra Morena Blvd. S.W. Calgary, Alberta, Canada T3H 4H9 Tel Phone : (403) 256-4151 www.statesmangroup.com 03/15/24 1248-001PROJECT NAMEE2.7 PLAN 7 LIGHTING 1" = 50'-0"E1.1 PLAN 7 LIGHTING 1 DRAFT Exhibit 35