Loading...
HomeMy WebLinkAboutBLD2005-00427 BOLDING PERMIT APPLICATI; MLA05 00397 Review Type: I Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD05-00427 Received Date: 6/27/2005 SITE ADDRESS: 4595 EAGLEMOUNT RD CHIMACUM, 98325 OWNER: ANDREW L DRISCOLL PHONE: 360 732-4426 KAREN M DRISCOLL 4595 EAGLEMOUNT RD CHIMACUM WA 983259735 SUBDIVISION: Block: Lot: PARCEL NUMBER: 801044002 Section: 4 Township: 28 N Range: 01 W CONTRACTOR: OWNER/BUILDER PHONE: REPRESENTATIVE: PHONE: PROJECT DESCRIPTIOI AGRICULTURAL BARN FOR FLOWERS TYPE OF WORK GAR SQUARE FOOTAGE: TYPE OF IMP NEW MAIN: 1,080 VALUATION 54,871.00 ADD'L: 480 HEAT TYPE: UH CODE EDITION: 2003 HEAT BASE: HEAT TYPE: OCCUPANCY: OCCUPANCY: UNHEATED: # OF STORIES: 2 CONST TYPE: OTHER: SHORELINE: GARA CONST TYPE: DECKLE 768 SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: CON WATER SYSTEM: PWELL BEDROOMS: BATHROOMS: Exist: 2 Exist: 2 Prop: 0 Prop: 0 Total: 2 Total: 2 Routing Date: (/029 /a x 3 Type Amount Paid Bv: Date: Receipt: w ��d�1� State Building Code $4.50 RAC 06/27/05 73406 H Plan Check $441.19 RAC 06/27/05 73406 AUG - 5 2005 Permit $678.75 RAC 06/27/05 73406 Total: $1,124.44 Jeffer County Planning :u , Department w1f �` Foy- • • BUILDING PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD05-00427 Received Date 06/27/2005 SITE ADDRESS: 4595 EAGLEMOUNT RD Issue Date 08/5/2005 CHIMACUM, 98325 APPLICANT: ANDREW L DRISCOLL PHONE: 360 732-4426 KAREN M DRISCOLL 4595 EAGLEMOUNT RD CHIMACUM WA 983259735 SUBDIVISION: Block: Lot: PARCEL NUMBER: 801044002 Section: 4 Township: 28 N Range: 01 W CONTRACTOR: OWNER/BUILDER PHONE: PROJECT DESCRIPTION: AGRICULTURAL BARN FOR FLOWERS CALL IN FOR THE REQUIRED)N�SPE`QTIQNS THAT APPLY TO YOUR PROJECT. SETBACKS: // 2A' /llSDS UFFER: ND Footing: 4l4 Foundation: //50.5 Stormwater FINAL Approval: Underground Plumbing: /Underground Insulation: `" Shear Wall : Sheathing: Framing: OK it -04,4S/ Plumbing: Propane Tank/ Lines: Insulation: Sheetrock: Septic Sytem Final Approval (If not on sewer): Road Approach Final Approval: Zoning Final Approval: Final/Occupancy Approval: Off( -cc1- -c,;AO /:1/I.i/D22 HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. CALL 24 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. Office Hours 9:00 a.m. -4:30 p.m. HOT LINE AVAILABLE 24 HOURS A DAY SPECIAL CONDITIONS APPLY - SEE REVERSE SPECIAL CONDITIONS FOR CAC BLD05-00427 • 1.) The project is located in close proximity to an identified wetland and is subject to the delineation provisions of Section 3.6.9 of the Jefferson County Unified Development Code. Based upon the proposed location of the project in relation to the identified wetland, the applicant has agreed to maintain a buffer(setback) that exceeds the standard buffer requirements by fifty (50) percent. The applicant acknowledges the additional setback and agrees to maintain the extra 50 percent buffer, therefore, waiving the wetland delineation requirements of the Unified Development Code. 2.) Buffer perimeters shall be marked with temporary signs at an interval of one per parcel or every one hundred (100) feet, whichever is less. Signs shall contain the following statement: "Wetland & Buffer- Do Not Remove or Alter Existing Vegetation." 3.) A permanent physical separation along the upland boundary of the wetland buffer area shall be installed and permanently maintained. Such separation can include installing logs, trees, a hedgerow, or any other prominent physical marking approved by the UDC Administrator. 4.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin. 5.) The identified Fish and Wildlife Habitat Area (Type 5 Stream), shall maintain a vegetative buffer setback of 50 feet. The setback shall be measured horizontally from the Ordinary High Water Mark (OHWM) to the agricultural barn for flowers. 6.) An additional setback of five (5) feet is required from the edge of the buffer area to the proposed agricultural barn for flowers. 7.) A permanent physical separation along the boundary of the buffer area shall be installed and permanently maintained. Such separation can include installing logs, trees, a hedgerow, or any other prominent physical marking approved by the UDC Administrator. 8.) Buffer perimeters shall be marked with temporary signs at an interval of one per parcel or every one hundred (100) feet, whichever is less. Signs shall be in place prior to and during construction activities. The signs shall contain the following statement: "Buffer- Do Not Remove or Alter Existing Vegetation." 9.) Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard. 10.) Not more than two (2) unlicensed or inoperable vehicles shall be stored on any lot less than one-half acre unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Unified Development Code (UDC) Section 6. Outdoor storage of thirteen (13) or more unlicensed or inoperable vehicles is prohibited except in those districts where specified as an automobile wrecking yard or junk (or salvage) yard and allowed as a Permitted Use in Table 3-1 of the UDC, and such storage shall meet the requirements of UDC Section 4.10. In no case, shall any such unlicensed or inoperable vehiclesbe stored in an Environmentally Sensitive Area (ESA). 11.) Maximum lot coverage is not to exceed 10%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc. 12.) The building height is not to exceed 35 feet. 13.) Minimum setback from Eaglemount Rd right-of-way is 20 ft. Minimum side and rear setbacks are 5 ft. Environmentally Sensitive Areas further impact setbacks. 14.) The project shall comply with Construction Stormwater Pollution Prevention (SWPP) Elements#1 through#12 of the Department of Ecology's Stormwater Management Manual for Western Washington to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. I:\F_BLD_Permit_Buildng.rpt 10/29/19 "ifflit.-^; S0Nco JEFFERSOCOUNTY0 DEPARTMENT OF COMMUNITY DEVELOPMENT 4 621 Sheridan Street • Port Townsend •Washington 98368 360/379-4450 • 360/379-4451 Fax �y�, p'� www.co.jefferson.wa.us/commdevelopment JUN 2 7 2005 Master Permit Application MLA: p () Cb '} Project Description(include separat�pe heets as necessary):. __, Tax Parcel Property 1 Number: g C) 1 - 0 Li y -C Z Size: 26 et o r e s (acres/square feet) .Site Address and/or Directions to Property: `+J-y c Fay i ,,• :,t.t 4- I R<1 . L. 9 '3 c 3� l Property Owner(s)of Record: Rtv .D rk G W L• CO' I<14/713 A., tf, .Di z IS c `t_. Telephone: 7 3 L - 'l tf z 6- Fax: email: rI,„ ; I cl 0,I jr `.. •c V,ti Mailing Address: S c:..,,. c: S y L 1, e Applicant/Agent(if different from owner): Telephone: Fax: email: Mailing Address: What kind of Permit?(Check each box that applies) Building ❑Variance(Minor, Major or Reasonable Economic Use) ❑ Demolition Permit ❑ Conditional Use[C(a),C(d),or C]** ❑ Single Family ❑ Discretionary"D"or Unnamed Use Classification ❑ Garage Attached/Detached ❑ Special Use(Essential Public Facilities)** ❑ Manufactured Home ❑ Boundary Line Adjustment ❑ Modular ❑ Short Plat** ❑ Commercial* ❑ Binding Site Plan** El Change of Use ❑ Long Plat** ❑Address Cl Road Approach ❑ Planned Rural Residential Development(PRRD)/Amendments** ❑ Propane ❑ Plat Vacation/Alteration** ❑Allowed"Yes"Use Consistency Analysis ❑Shoreline Master Program Exemption/Permit Revisions** ❑ Stormwater Management ❑ Shoreline Management Substantial Development** ❑Site Plan Approval Advance Determination(SPAAD)* ❑ Shoreline Management Variance ❑Temporary Use ❑ Comprehensive Plan/UDC/Land Use District Map Amendment ❑Wireless Telecommunication* ❑Jefferson County Shoreline Master Program Amendment ❑ Forest Practices Act/Release of Six-Year Moratorium *May require a Pre-Application Conference _ **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: DESIGNATION OF AGENT I hereby designate to act as my agent in matters relating to this application for permit(s). OWNER SIGNATURE Date: By signing this application form,the owner/agent attests that the information provided herein,and in any attachments,is true and correct to the best of his,her or it's knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and any required later inspections.Access and right of entry to this property shall be requested and shall occur only during regular business hours. /� t� _ '_� 7/ Signature: ��2�—r1�,-�-c., `— � � �. S`Date: The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential"take"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non-transfe e responsibil9 for adhering to and co lying with the ESA. The Applicant has read this disclaimer and sig s and dates it below. Signature: �� 7 .. .. Date: �SZ ��C' S� G:\PermitCenter\FORMS\DRD FORMS\Master Permit Application 7-8-04.doc OWNER BUILDER STATEMENT • The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be ass min the responsibility of the General Contractor for the proposed project. Signature:(�. j z�, ,✓sp�� 4 Date: GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX: ( ) ( ) MAILING ADDRESS: EMAIL: CONTRACTOR'S LICENSE WAINS NUMBER: NUMBER ARCHITECT/ENGINEER: PHONE ( ) FAX:( ) MAILING ADDRESS: EMAIL Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal: ,$j New Wood Existing: ❑ Sewer ❑ Addition ❑ Steel Proposed: 0 Bank ❑ Community System ❑ Alteration/Remodel 0 Concrete Total: 0 Height: 0 Individual System 0 Repair 0 Masonry SEP Permit# Gf 8- 7 — 0 Demolition ❑ Other: Bedrooms: Water Supply: Existing: Setback: P Type of Heat: Proposed: a ` rivate well ❑ Two Part Y ❑ Public �v c Total: Name of System: If this is a Commercial Project you must answer the following: Number of Parking Spaces: Current Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants,employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: 0 Underground Tank ❑ Above ground Tank Size of Propane Tank: t 1 Heat Stove 0 Cook Stove 0 Woodstove ❑ Fireplace Insert ❑ Hot Water Tank i l Pellet Stove ❑ Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines, tank location and size,distances from the propane tank to all property lines,buildings and septic system components, including the reserve area. _ Square Footage For Office Use Only Current Proposed Amount Main Floor /O 8 J ,� (l(J Consistency Review: r 2""Floor t 4.0 Base fee: 11 i.3. 3ro Floor I Additional Section: t ` Mezzanine: Plan Check fee: t c Heated Basement I State Surcharge fee: ,-, CSC) Unheated Basement Pot Water Review fee: Other Unheated (� j©l�r7Cy 911/Rd Approach fee: Garage/Carport ` , f �C ts�t n �� TOTAL: $ / -14 Decks / . / �� . /ecelpt Number,._. '1J 3 Other I . 1 Cash/Check'Number: ESTIMATED COST(REQUIRED) Date: ,. •Fair market value of all/labor and materials foundation to finish re 7:->5G:\PemutCenter\FORMS\DRD FORMS\Master Permit Application 7-8-04.doc ` •I • m ,0 > (T.A.N, 801043003p - M !. ill 2 c °� D ir co 1. -h— — -� o m =z� CD c''r*1Won N 1 III I0 o� oQ c \., ... c No a� • IoI o B t p ,� �•{�z J T ON�JVZ^ I "m mA C 1...1 � I I I O (IWO L/ I � CO N Z Otrl /� II II II II II II II II II II T oz n W m � w r0 � z M � 0 om �m � IV �n � =no p I M 92 1-73 _ -< m om �Om b Cn Z I Z O mv0 0 < 0 WC �Z � II +� r OC m 0r C 'T1 DmgZr CD 0 r- I rnvz m ri �rnz _ O O I- t7 m Crl \/ I IC t -y 0 v) 71 z I N 71 1- rris73 CC H yN o 1n Cn c , \ II (Cr) N I N CO 1n _ I m - _ TOP 0 BANK . •\ ..y.._ I _212 .... 214 ...._ - _ _216 on o w I 'SOP OF B / �Or pas - -,2":/ ' I ''' O I ^'� I / , c-m 63. .., 1 -,- , 2 I I i/\ ‘':' 13 - -7: / ...--0 0......ii.1,.., „,,---(.,„6, b, 1 I tv N /'H --- 1y� I ���` WI NoA♦W�}Q N c:o -F. I� I \ O II /,'' r` s- te � - ` i \ F � o \ , / Cp -o ' \ \ 6--- 7 0 I / s \ \ \ Cl 'Irti/ \ .....• 2, ,.., / N p I \.\ I I • 1 / o (A0. ;\ , I m I I,/ a \ ‘3 Vpi,, 1 ,---1 \ t'''.1 , .70 \ 1 \ Fn r- _ S -1 '' T\ I ' I-N-10 • O i \ \ I i C ' r 0 CIi j rn x C11 .D O ; ,\. 1 / '''„,.. •‘..71. \..'' .- .-- .t•C") -C' 3)/ -_ -- --- � r .z N • o m C WIIVVVWWV` " :. �, m aa1 I 0 . .0-6 IIIIIIII ` 101 J' m 1 D Z0 pj v Jh� I /�I.. •2�8 1 (n v 4a co-IZ•• fri T Y� I I 0 CnNQ .:\ I f 1 r cD t p .. I r I I I \\,,11111111111111111h:.':!'IIIIIIIIIIIIIIII/Iii�i I I �` a O cofTm = - 1JXZ I18" CONC. I , ti ra.�� e o D p p Z c. I CULV. I 7.1 .� 4 •' o• Nb � • 1 4. _ v _ Z 2 0 C ON3N g di D m I $ `0.?'•y _ < zoz cf)0 Z Z 1n I _ `� �-' cvn Re 0 O �`- D ' I '''"iamuunuID::P71o1Immm111111►```` Z = > r z I e- M rn O O I o N �' m I rrn —I • 1302.90' O 411 -0 ,.1- v N 00'59'47" E zvN Z 1P3 N. �>K ��� N $ �o � los. 1,.- zao' - ci-1,1111 .11111t).... --- ha. co �cmZ� 0 v JUL 11 2M5 cNT 48" wide 3/8" wood structural panel 6d @ 6"oc/12"oc Sole plate nailing (3)16d every no ho4downs re�uqied i i,465 fstAus�) 1 . r I I-�' C �N�I llVtlU4a I //nG7 rtiC.. I� I� Fo e% 7 TNG- R311.5. Handrails. Handrails shall be provided on at least one side of each �. continuous run of treads or flight with four or more risers. Handrails shall not be less than 1\. 34" and not more than 38" measured up from the toe of step. R311.5.3 - Stair treads and risers. The maximum riser height shall be 7-3/4 inches. The minimum tread depth -"thall be 10". Including, step down to landings grade deck patio etc Section R502.9, Fastening, 2003 IRC Where posts and beam or girder -- Section R303.6 - 2003 TRC 'construction is used to support framin , All interior and exterior stairways positive connections shall be provided to Shall be provided with a means tp�\ ensure against uplift and lateral di--lacement. TLilluminate the stairs, including thej _ A4nding and stairs. Sty 1LS l4.s' 1 e> �Co A ! IBP: Section R602 10 4 — 2003 IRC Shall be at least 96" in length where / to one face, and at least 48" where e to both faces 112" gwb-5d nails-7" oc blocked 0 112" gwb-5d nails�_l"oc unblocked W irk xI� CClWl-,h aX(Z7S15t5 PI1,41Zer., poen,� 9X1z� i f Ili 7 x / Ct�Ni trJL•tf+*2 I t F"e,aTtr.eG t ,Ak R 8, Glazing,- 2003 IRC All glass located in areas considered hazardous must be safety glazing and � Cidentified by manufacturer's or installers label. (acid etched in glass) o a 6 `-- x3 sl,d�� TOw0 Fm r --T^ c ,yu Aq lu L-18r' �RiQ Nam— 16 Section R319.2003IRC. /'/} Wood members that form the stfuctural \ /� }{ /1 ' J !I supports of balconies, porches or 1 , / (J �/ } similar building appurtenances shall be approved natural resistance to decay or R319.3 Fasteners. 2003 IRC 'F„,Vteners for pressure treated wood shall 1 pressure treated wood. be of hot dipped galvanized steel, stainless steel, silicone bronze or copper. / Exception: One-half inch diameter or greater steel bolts t9c ----- - ------ -- 3_At- La -- 7-3 ;Z - `1 y a 6 3 r