Loading...
HomeMy WebLinkAboutBLD2006-00141 JILDING PERMIT APPLICAT. MLA06-001 38 Review Type: I Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD06-00141 Received Date: 3/28/2006 SITE ADDRESS: 334 PORT HADLOCK HEIGHTS RC PORT HADLOCK, 98339 OWNER: BRODERS INC PHONE: 360-797-7722 4503 OLD GARDINER RD PORT TOWNSEND WA 983689778 PORT HADLOCK HEIGHTS MH PARK SUBDIVISION: Block: Lot: 22 PARCEL NUMBER: 989500001 Section: 11 Township: 29 N Range: 01 W CONTRACTOR: W D MCCUTCHEN CONSTRUCTION : r 2 t7 3 PHONE: -t,� PO BOX 974 PORT HADLOCK WA 98339 Contractor's License WDMCCC*054L1 Expires 6/10/2007 REPRESENTATIVE: PHONE: PROJECT DESCRIPTIOI NEW DETATCHED UNHTD GARAGE TYPE OF WORK GAR SQUARE FOOTAGE: TYPE OF IMP NEW MAIN: VALUATION 32,136.00 ADD'L: HEAT TYPE: UH CODE EDITION: 2003 HEAT BASE: HEAT TYPE: OCCUPANCY: R-3 UNHEATED: # OF STORIES: OCCUPANCY: OTHER: CONST TYPE: 5N GARAGE: 1,520 SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: CMY WATER SYSTEM: PUD BEDROOMS: BATHROOMS: Exist: 0 Exist: 0 Prop: 0 Prop: 0 Total: 0 Total: 0 Routing Date: 2 ?i/D(„) Type Amount Paid By: Date: Receipt: A P 3 V E r Permit $472.05 LYK 03/28/06 79296 �/ Plan Check $306.83 LYK 03/28/06 79296 APR a.I 2006 State Building Code $4.50 LYK 03/28/06 79296 Total: $783.38 Jefferson County Planning & Building Department • • BUILDING PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD06-00141 Received Date 03/28/2006 SITE ADDRESS: 334 PORT HADLOCK HEIGHTS RD Issue Date 04/21/2006 PORT HADLOCK, 98339 APPLICANT: BRODERS INC PHONE: 360-797-7722 4503 OLD GARDINER RD PORT TOWNSEND WA 983689778 SUBDIVISION: PORT HADLOCK HEIGHTS MH PARK Block: Lot: 22 PARCEL NUMBER: 989500001 Section: 11 Township: 29 N Range: 01 W CONTRACTOR: W D MCCUTCHEN CONSTRUCTION PHONE: PO BOX 974 PORT HADLOCK WA 98339 Contractor's License: WDMCCC*054L1 Expires: 6/10/2007 PROJECT DESCRIPTION: NEW DETATCHED UNHTD GARAGE (Lot 33) CALL IN FOR THE !FRED INSPECTIONS THAT APPLY TO YOUR PROJECT. SETBACKS: UFFER: Footing:(IL- V 461/tV 12_-S —€ Foundation: Stormwater FINAL Approval: Underground Plumbing: Undergro Ins ati n: Shear W II : "7 Sheathing: Framing: Plumbing: Propane Tank/ Lines: Insulation: Sheetrock: Septic Sytem Final Approval MUST be obtained before final of structure can be attempted. Road Approach Final Approval: Zoning Final Approval: Final/Occupancy Approval:`,C I 0- t3-o f HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. CALL 24 HOURS IN ADVANCE TO SCHEDULE INSPECTIONS. Office Hours 9:00 a.m. -4:30 p.m. HOT LINE AVAILABLE 24 HOURS A DAY SPECIAL CONDITIONS APPLY - SEE REVERSE SPECIAL CONDITIONS FOR CASE t BLD06-00141 4111 1.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin. 2.) To help prevent seawater from intruding landward into underground aquifers, all new development activity on Marrowstone Island, Indian Island and within 1/4 mile of any marine shoreline shall be required to infiltrate all stormwater runoff onsite. 3.) VOLUNTARY MEASURES OF COASTAL &AT RISK SIPZ: Water conservation measures: 1. Roof and other intercepted precipitation shall be routed to on-site detention ponds and/or other approved means and allowed to be released to the soil slowly. 2. Water collected from Storm water and roof catchments may be used for watering lawns and gardens. Unless catchment water has been treated to meet drinking water standards, there shall be no cross connections allowed between the potable supply and impounded water. 3. Water withdrawn from wells on each property shall not be used for watering of lawns and/or gardens. 4. Ground water withdrawn from each property shall be restricted to a rate of three (3) gallons per minute. 5. Installation of water conserving fixtures such as low flow toilets, faucets and shower restrictors and other water saving plumbing fixtures. 6. Landscaping plan (xeriscaping, native vegetation with minimal amounts of irrigation). Please NOTE that the above listed measures are not intended to be exhaustive, but rather is intended to be illustrative of the types of water conservation measures. 4.) VOLUNTARY MEASURES OF COASTAL &AT RISK SIPZ: 1. Installation of a flow meter. 2. On-going well monitoring for chloride concentration. 3. Submittal of monitoring data to County. 5.) MANDATORY MEASURES FOR COASTAL SIPZ: 1. For proof of potable water on a building permit application, applicant must utilize DOH-approved public water system if available. 2. If public water is unavailable, a qualifying alternative system may be used as proof of potable water or an individual well may be used as proof of potable water subject to the following requirement: a. Chloride concentration of a laboratory-certified well water sample submitted with building permit application. 3. If public water is unavailable, a qualifying alternative system may be used as proof of potable water. 6.) The property owner shall comply with Water Conservation Measures (per list maintained by the UDC Administrator). 7.) The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 8.) Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard. 9.) Not more than two (2) unlicensed or inoperable vehicles shall be stored on plot less than one-half acre unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Unified Development Code (UDC) Section 6. Outdoor storage of thirteen (13) or more unlicensed or inoperable vehicles is prohibited except in those districts where specified as an automobile wrecking yard or junk (or salvage)yard and allowed as a Permitted Use in Table 3-1 of the UDC, and such storage shall meet the requirements of UDC Section 4.10. In no case, shall any such unlicensed or inoperable vehiclesbe stored in an Environmentally Sensitive Area (ESA). 10.) Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc. 11.) The building height is not to exceed 35 feet. 12.) Exterior lighting for residential uses shall not exceed twenty feet (20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged. 13.) Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way. 14.) I:\F_BLD_Permit_Buildng.rpt 10/29/1999 • = (... ci r_ --r It 4i)0 CP 0 -S) i 0 • id It) t71 q' if) -..... in \I E N. E• _ --4 t3..) . .,. „ "1041111111 i el ,,,..e. .?''',:- . 1 A / . ...,,F.... .... „ , i -. 1 '4 ---I — -ST) ...._ L , IP Si‘ 9 v, —0 ; c s., f,p do, I ' i' 7' : -- . I lie Cl* Ci ig ---r) —c) ....... , r c,,,irli•"`21 ) , .4 4- 1> r y (-..---,, F (( ,i. 1 crk i -,%-.1 t" v --r- V--- . ..+.-. -/-- (' _ CO , It- 5 co ly —ci , -------4—:77—i /1 3 --, $6°*c'j P -, - 1 c•-• , rj 1 i'• I. Cr) i, 3 s, " tki :x Z te. . I- \! r IP) Crl lij) ki 1 A.- 8 id A— _ r d 6 S.:-: , 6 kA1 —0 Gs' 0 47 *=• , o.,, \ ICJ Q* kl "C- V) -...-r -4--i, ri ‘,1 r Qt) -I— -f-- 16 4-3 V° ;5;_ ...> — -I— -1 N 0 ..,- ' . 0 __- ---, 0 kikAl I) _.........._, 1 1 rri 4 .. 73 Cr) -• . 'V CD 6 . . , z , c„sv g , , c.... rim rri c) rrs — , = =a <13 -.z ).• t,.< r .., ...v... MP 0 r...1 rri co rri = 1 oo = == 6 'C'n , cA p:1 c4 .m4 . .,. C")c== a: = 0•0 t.i0 tt, -9 L \ ...< ..i., =. tT, 0 7.” = ,....„4. 0 Ft r ti _., __.... . .1* N•i ''/At= ' IS' , • . . • BUILDER STATEMENT • The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be assuming the responsibility of the General Contractor for the proposed project. Signature: act. Date: GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX: ,L.) . rn -c)k1,(\ (..c2),n 5 k ( . o) lc) 1 . c;7 3 ( ------ MAILING ADDRESS: 00 i:SCX q7t•{ 'N'A ilnel la* EMAIL: 9 339; CONTRACTOR'S LICENSE WAINS NUMBER: W in c e e '-1 / r NUMBER ARCHITECT/ENGINEER: Vv D �,~�/{` C� q� {^]+ i ( ) ►t�k , 0 4y. lr rc,l,Ai PHONE ( - .�i}"�?lY AX: MAILING ADDRESS: Project Type: �`(.16 I rr)r+Sel n 5+_ . 4- EMAIL .a , ‘1 . r i 1 Frame Type: Bathrooms: Shoreline: ype of Sewage Disposal: (' New ,Wood Existing: ❑ Sewer ❑ Addition 0 Steel Proposed: Bank Height: Community System ❑ Alteration/Remodel ❑ Concrete Total: 0 Individual Sy$e ‘,....."- 0 Repair 0 MasonrySEP Permit# �i'�r.> ❑ Demolition ❑ Other: Bedrooms: Water Supply: Existing: Setback: pp y Type f eat: Proposed: ❑ Private well ❑ Two Party po Total IfPublic Name of System: If this is a Commercial Proiect you must answer the following_ Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants, employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: [i Underground Tank I I Above ground Tank Size of Propane Tank: ❑ Heat Stove C Cook Stove ❑ Woodstove 11 Fireplace Insert 0 Hot Water Tank [1 Pellet Stove 0 Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines, tank location and size,distances from the propane tank to all property lines,buildings and septic system components, including the reserve area. Square Footage I Current Proposed For Office Use_ Only Amount Revision Main Floor Heated EH Bld App Review: Floor Heated Consistency Review: 1 r `� J Other Heated Base fee: !� ^� Mezzanineel W Additional Section: Heated Basement -Plan Check fee: 3 o�Q . S' 2 Unheated Basement State Surcharge fee: 50 Other Unheated - Pot Water Review fee: Garage/Carport G 102- o t tux SUBTOTAL 2-Ql 15 U) C-ifr�ut (-(ctN 0WI ' 3(�1 Decks J l . 911/Rd Approach fee: 1 Other TOTAL: $ „.„........------' �, ceipt Number_ q'1 q `2"� ��Ga h/Check Number: o� t / ESTIMATED COST(REQUIRED) ete2 8 2006 i.Fair market value of all labor and materials and kw te-finish ! / p2�/� 3OD° Initials: 1 ! , G:\PermitCenter\FORMS\DRD FORMS\Master Permit Application t2-30-05.doc i i.OPIv'rN C i ON • . L'O JEFFER COUNTY r - ----- /�` DEPARTMENT OF COMMUNITY DEVELOPMENT �', '�,I 621 Sheridan Street • Port Townsend •Washingto 983.: " ' . 360/379-4450 • 360/379-4451 Fax �Y i i p www.co.jefferson.wa.us/commdevelopmMlii 2,1r t l i �`SHING J Master Permit Application MA: D(Q - 1 J� Project Description (include separate sheets asinecessary):` _"` /`/ �. A i •'tr2. C.-4 C >�'1 5 key) /3`'I ru'•og Property Tax Parcel Number: v�9 5'O 000 t Size: j'L)ci (,"(6 5 v tl -i- (acres/square feet) Site Address and/or Directions to Propertya7 Pori— im_D;64 /fir hr 1. , ►u) Property Owner(s)of Record: ,PP,-r2L.5,Vc� 6Sfr.9-Zia-V4S, 2/‘,A,6,9 d H///e/tip Telephone: g 2& . 71/-0/D 6 Fax: email: L=PSr/9/06f,("" /roil.) Mailing AddressPLk EJ1 id-% 77/3i i /fiFiJLoc,' , ii 9 S- 5 C Applicant/Agent(if different from owner): L2 O �Yl`L Vc,Y Y Lin 5-P UJi0Vs) Telephone: 3(00 0I .)-U 73 Fax: email: Mailing Address: J O i, ;x q 1w PO 4 /I PLO t n4 `i a 3•','{ What kind of Permit?(Check each box that applies) Building ❑Variance(Minor, Major or Reasonable Economic Use) i l Demolition Permit ❑ Conditional Use[C(a), C(d),or C]** Single Family ❑ Discretionary"D"or Unnamed Use Classification Garage Attached(Detache ❑ Special Use(Essential Public Facilities)** ❑ Manufactured Home ❑ Boundary Line Adjustment LI Modular ❑ Short Plat** ❑ Commercial* ❑ Binding Site Plan** ❑ Change of Use ❑ Long Plat** ❑Address ❑ Road Approach ❑ Planned Rural Residential Development(PRRD)/Amendments** ❑ Propane ❑ Plat Vacation/Alteration** ❑ Allowed "Yes"Use Consistency Analysis ❑ Shoreline Master Program Exemption/Permit Revisions** ❑ Stormwater Management ❑ Shoreline Management Substantial Development** ❑ Site Plan Approval Advance Determination(SPAAD)* ❑ Shoreline Management Variance ❑Temporary Use ❑ Comprehensive Plan/UDC/Land Use District Map Amendment ❑Wireless Telecommunication* ❑Jefferson County Shoreline Master Program Amendment ❑ Forest Practices Act/Release of Six-Year Moratorium *May require a Pre—Application Conference **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: J ) / •DESIGNATION OF AGENT I hereby designate /l� I r 1-- 1 to/t s agRnt in atters relating to this application for permit(s). SIGNATURE iC� /' /./`.L �"rt� � - / /l� ` Date: `/:tea/�Lo OWNERk By signing this application form,the er/agent attests that the information provided herein,and in any attachments, is true and correct to the best of his,her or it's knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs, reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections.Access and right of entry to this property shall be requested and shall occur only during regular business hours. q (/ Signature: 8 it) /1 `y" �l-{t�t�t 17�l t-Cn'1 Date: ..- 4 ,'o(Q The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential"take"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s) even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non- transferable responsibility for adhering to and complyi with the ESA. The Applicant has read this disclaimer and sign and date it bel w. IJ Signature: CV pl�-4 '1.c,- to • Date: •% Si (3 7 G:\PermitCenter\FORMS\DRD FORMS\Master Permit Application 12-30-05.doc