INTRODUCTION
This report summarizes our site observations and conclusions, and provides
recommendations and design criteria for the support of the proposed addition to the
existing residential structure at the site. We understand that you propose to construct an
addition to the northeast portion of the residence (front yard) and remodel the
stairway/deck located at the southwest portion of the existing structure. The remodeled
timber deck will be elevated and supported on conventional foundation elements. The
proposed addition will be situated towards the street, away from the critical slope area.
The stairway/deck remodel will be situated in a flat to gently sloping area, also away
from the critical area.
The purpose of our services is to review the available geotechnical data for the
area and provide foundation support recommendations and design criteria for the
proposed addition and deck remodel. Mr. Biggerstaff, the undersigned is familiar with
the site and surrounding area, having previously provided geotechnical reports in the site
area. Our services are provided at your request and based on our review of the
available soils and geologic data for the site area, and our site reconnaissance and data
review.
The project site is situated in an area of existing residential plat development.
Vegetation at the site generally consists of grasses with scattered ornamental shrubs
and small trees that surround the existing residence. The proposed addition and deck
area are in the flatter portions of the lot, greater than 10 feet from the steeper sloping
areas. The soils in the site area typically consist of a veneer of glacial soils over
weathered basaltic bedrock. The surficial soils are in a medium dense condition. The
underlying undisturbed glacial soils and bedrock material are typically in a dense to hard
condition.
No active groundwater seepage was observed at the site at the time of our site
visit. No evidence of erosion or slope instability was observed at the site or the adjacent
areas at the time of our site visit. No evidence of foundation distress was observed on
the existing residential foundation at the site.
CONCLUSIONS AND RECOMMENDATIONS
Based on our site observations and experience in the area, the site is suitable for
the proposed addition and deck/stairway remodel. The new foundation elements for the
addition can be supported on the undisturbed medium dense or denser native soil or on
properly compacted structural fill. The new foundation elements can be designed using an
Olympic Ridge—Raini�ne
January 10, 2008 •
Page 2
JAN 2 2 2008
allowable soil bearing pressure of 2,500 psf for combined dead and lon6-term live loads,
exclusive of the weight of the footing and any overlying backfill. Where the footings are
founded on the undisturbed very dense glacial till or bedrock soils, the allowable bearing
pressure may be increased to 3,500 psf. These values may be increased by one-third for
transient loads such as those induced by seismic events or wind loading.
We recommend a minimum width of 16 inches for isolated footings and 24 inches
for continuous wall footings. All exterior-footing elements should be embedded at least
18 inches below the lowest adjacent finished grade. We recommend that any disturbed
soils in the footing excavations be removed, or if practical, recompacted prior to concrete
placement.
We estimate that settlements of footings designed and constructed as
recommended will be less than 1 inch, with differential settlements between comparably
loaded footings of 1/2 inch or less. Settlements will occur essentially as loads are applied.
Disturbance of the foundation subgrade during construction could result in larger
settlements than predicted.
We recommend that all foundations for the addition be provided with footing drains.
Roof drains for the new addition should not be connected to the footing drain system
unless adequate measures are taken to prevent surcharge of the footing drains. The new
roof runoff maybe directed to the existing stormwater system.
Foundation support for the deck/stairway remodel may be supported conventional
foundation elements that extend below the surficial topsoil and loose weathered soil
materials. We expect that this will require between 12 and 24 inches of embedment.
FLOOR SLAB SUPPORT
If slab-on-grade floors are utilized, they should be supported on medium dense or
denser native soil or on structural fill prepared as recommended above.
We recommend that floor slabs at the site be underlain by a 4-inch thickness of
uniformly graded gravel or sand containing no more than 3 percent fines to provide a
capillary break. The capillary break material should be placed in one lift and compacted to
a minimum of 95 percent of the MDD. The capillary break material should be connected
to a suitable drain outlet to provide an exit for any accumulated seepage.
A vapor barrier, such as a polyethylene liner, is also recommended. A thin
layer of "clean" sand may be placed over the vapor barrier and immediately below the slab
to protect the polyethylene liner during steel and/or concrete placement.
A subgrade modulus of 400 kcf (kips per cubic foot) may be used for design. We
estimate that settlement of the floor slabs designed and constructed as recommended,
will be 1/2 inch or less over a span of 50 feet.
LATERAL RESISTANCE
Lateral loads may be resisted by friction on the base of footings and floor slab and as
passive pressure on the sides of footings. We recommend a coefficient of friction of 0.35
be used to calculate friction between the concrete and soil. Passive pressure may be
determined using an equivalent fluid weight of 300 pcf (pounds per cubic foot). This
assumes that structural fill is placed against the sides of the footings and that the top of the
fill is confined by either a concrete floor slab or pavement. A safety factor of 1.5 is
conventionally applied to these values.
RETAINING AND SUBGRADE WALLS
Retaining and/or subgrade walls are not expected at this site. Deep basements are
not recommended. However, in the event that shallow subgrade walls are required (stem-
type walls), they can be supported on shallow footings founded on dense native soils or
structural fill, if properly prepared. Footings bearing on undisturbed native soils or
Olympic Ridge—RainillOne .
January 10,2008
Page 3
structural fill as described above can be designed using an average allowable bearing
value of 2,500 psf with a maximum toe pressure of 3,500 psf, when the adjacent downhill
slope is 4 to 1 (horizontal to vertical), or flatter.
Lateral loads on conventional retaining structures founded as described above may
be resisted by friction on the base of the wall footings and as passive pressure on the
sides of footings. We recommend using an ultimate coefficient of friction of 0.35 to
calculate friction between the concrete and dense native soils or on structural fill. Passive
pressure may be determined using an equivalent fluid weight of 300 pcf. This assumes
that structural fill is placed against the sides of the footings. A safety factor of 1.5 should
be applied to these values, for sliding and overturning.
The lateral active soil pressures acting on reinforced concrete retaining walls depend
on the nature, density and configuration of the soil behind the wall. We recommend that
walls supporting horizontal backfill be designed using an equivalent fluid density of 35 pcf
for a level back slope behind the wall. This pressure is based on backfill placed within 2
feet of the wall being compacted by hand-operated equipment to a density of 90 percent of
the MDD and consisting of clean sand or sand and gravel. The recommended pressure
does not include the effects of surcharges from surface loads.
LIMITATIONS
We have prepared this report for use by Olympic Ridge and members of the
design team, for use in the design of a portion of this project. The data used in
preparing this report and this report should be provided to prospective contractors for
their bidding or estimating purposes only. Our report, conclusions and interpretations
are based on data from others and limited site reconnaissance, and should not be
construed as a warranty of the subsurface conditions.
A contingency for unanticipated conditions should be included in the budget and
schedule. Sufficient monitoring, testing and consultation should be provided by our firm
during construction to confirm that the conditions encountered are consistent with those
indicated by the explorations, to provide recommendations for design changes should
the conditions revealed during the work differ from those anticipated, and to evaluate
whether earthwork and foundation installation activities comply with contract plans and
specifications.
Our recommendations are not intended to direct the contractor's methods,
techniques, sequences or procedures, except as specifically described in our report for
consideration in design.
If there are any changes in the loads, grades, locations, configurations or type of
facilities to be constructed, the conclusions and recommendations presented in this
report may not be fully applicable. If such changes are made, we should be given the
opportunity to review our recommendations and provide written modifications or
verifications, as appropriate.
!I
J A N 2 2 2008
_ J
Olympic Ridge-Rainieene •
January 10, 2008
Page 4
We hope this satisfies your current needs. If you have any questions regarding
this letter or need additional information please call me.
Yours Very Truly,
GeoResources, LLC
Bradley P. Biggerstaff, LEG Glen Coad, PE
Principal Principal
o�W ash `'CE`GLF,
lir 4e,AseK001) ,, V 0% ' // C.' ,
/4 if"'k:NO PI'a v ' 'r Z ' i e . .
o
eying Geofogis f ilk ,.4%4," ,i .ii:j4 r r or 'A '1'. ' (..., *-
c ,/tiT1 tiE` s
2228 /� „ S Wit+ ''
.S u ti/
BRADI_ ___ G . TAF� EXPIRES 10 !31 / o r/
BPB:GC:bpb
Docl D:OIyRdg.RainierLn.RG
lii—
r-----
L.....)
JA N 2 2 2008'::-7;11-)1 ?
i ,L..� r LOP',r1-=NT