Loading...
HomeMy WebLinkAboutBLD2008-00051 •UILDING PERMIT APPLICA N BLD08-00051Review Type: I Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD08-00051 Received Date: 2/7/2008 SITE ADDRESS: 512 MALAMUTE LN PORT TOWNSEND, 98368 OWNER: ALLAN H VANCE PHONE: 360-4170505 NANCY G VANCE PO BOX 6009 SAN RAMON CA 945830709 MOUNTAIN VIEW VISTA SUBDIVISION: Block: Lot: 14+ PARCEL NUMBER: 974600014 Section: 8 Township: 29 N Range: 01 W CONTRACTOR: KNIGHT FIRE PROTECTION INC PHONE: 360-417-0505 2509 W 19TH ST PORT ANGELES WA 98362 Contractor's License KNIGHFP044LK Expires 5/24/2008 REPRESENTATIVE: KNIGHT FIRE SPRINKLERS PHONE: (360)417-0505 2509 WEST 19TH (360) 452-8074 PORT ANGELES WA 98363 PROJECT DESCRIPTIOI RESIDENTIAL FIRE SPRINKLER - (FOR GAR/ADU) TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP NEW MAIN: VALUATION 3,700.00 ADD'L: HEAT TYPE CODE EDITION. 2006 HEAT BASE: HEAT TYPE: OCCUPANCY: OCCUPANCY: UNHEATED: #OF STORIES: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: Exist: Prop: Prop: Total: Total: Routing Date: J ff/0' Type Amount Paid Bv: Date: Receipt: Approved/Date Total: APPROVED FEB I5 2008 Jefferson County Planning &Building Department Jefferson County Building D ision Permit Nu.: BLD08-00051 Applicant: VANCE BUILDING PERMIT INSPECTION APPROVALS \pplicable Code: 2006 International Building Codes To schedule inspections, call (360)379-4455 no later than 7:00 AM the day of the inspection. Requests received after 7:00 AM will not be scheduled for that day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Hydrostatic Test 2/2.9/oB N a 42 z " Flow Test Fire Alarm Init. Device 6-(,`-t(Ji /20/0, FINAL INSPECTION FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR O.V �, • •• (---..„,„,s- o� JEFFERSON COUNTY � 3 DEPARTMENT OF COMMUNITY DEVELOPMENT -� `� 621 Sheridan Street• Port Townsend• Washington 98368 `\ _ 30U/3 y-44JU • ,Ou/J/y-445 i t-ax ,° — 7 2008\\-\ /.fl / ‘MN\A/rn IPffPrc"r, _ !c'^�mmrlo�rolnnmo . ?KZNt� , Master Permit Application MLA: \(O \L.1\ Project Description (include separate sheets as necessary): P,t--‹IQ 1149-L F- ILb- 9i2.1 3 Tax Parcel , Property 7 Number. 11 Ci`4' Size: (f-?4 ,ac.e quare feet) Site Address and/or Directions to Property: ci2 jtIQ n&k L4►14- ,OFC )L' 2' Property Owner(s)of Record: 11:11‘An il-n Q .EnL' VAA IC Telephone: Fax: email: Mailing Address: ?Et) f- kV-4'4 csti-, 114n11 , /r� 'f4C 33 Applicant/Agent(if different from owner): Vn► rt. F- r—irtL, 1 prtt.i.r c.krn 1 (N L Telephone0,Li[,)41")-&'5 dS Fax ema .i Mailing Address: 2 us el L )Eyr 141}t, ' i l'uj f t -+� �tc3 What kind of Permit?(Check each box that applies 'C� mot/ ❑Building ❑Variance(Minor, Major or Reasonable Eccrc-lc Use: ❑ Demolition Permit ❑ Conditional Use[C(a), C(d), or C)** ❑Single Family ❑Garage Attacr.ed I Detached ❑ Discretionary"D"or Unnamed Use Gass f;ca:c^ ❑ Manufactured Home ❑ Modular ❑Special Use(Essential Public Facilities;'* ❑ Commercial* ❑ Boundary Line Adjustment ❑ Change of Use ❑Short Plat** ❑ Address ❑ Road Apprcacr.. ❑ Binding Site Plan** ❑ Home Business ❑Cottageindustr/ E Long Plat** Propane C Planned Rural Residential Development,r-R.: A.merdments*" ❑ Sign ❑ Plat Vacation/Alteration *" C Allowed "Yes' Use Consistency Analysis ❑ Shcreiine Master Program Exemption/Permit Revis crs*` C Stermwater Management C Shoreline Management Substantiai Development" ❑ Site Plan Approval Advance Determination SPAAD)- ❑Shoreline Management Variance ❑Temporary Use ❑ Comprehensive Plan/UDC/Land Use District Mac,amendment ❑Wireless Telecommunication * C Jefferson County Shoreline Master P-dram ATercment ❑ Forest Practices Act/Release of Six-Year Moratorium ❑Tree Vegetaion Request *May require a Pre—Application Conference **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: AlC DESIGNATION OF AGENT I hereby designate dT61 to act as my agent in matters relating to this application for oermit(s). OWNER SIGNATURE ell-4A 6u(.c-P Date: cc- 2-c-wp7 By signing this application form,the owner/agent attests that the information provided herein,and in any attachments.is true aro carre~to the best of iI his,her or it's knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respell to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorneys fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and an ired later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the app n t r s e s prior notice. Signature: Date: ID('.Z16) The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential"take'of an endangered species as-those terms are defined in the federai law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even ou are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual /11 and non-transf We re ibil' adhering to and complying with the ESA, The Applicant has read this disci 'mer nd signs and dates it below. Signature: Date: tD O) • (.:\i)ucumcnts.tnd Settings\coral\1.ical Setting\Temporary Inrcrnct Vacs\t)1.KM\rMlaster Permit \ppiicatinn 1 2-1 9-211116.Jr,c • • • BUILDER STATEMENT The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be assuming the responsibility of the General Contractor for the proposed project. Signature: Date: GENERAL CONTRACTOR OR MANUFACTURED� HOME IN TALLER: PHONE: FAX: /<,v/o-/#t /7/ Je j-bC7rc4 , 4fc (1 J.P) Il)-0J-7 l ) MAILING ADDRESS: EMAIL: CONTRACTOR'S LICENSE WAINS NUMBER: NUMBER ARCHITECT/ENGINEER: PHONE ( ) FAX:( ) MAILING ADDRESS: EMAIL Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal: New Wood Existing: Sewer Addition Steel Proposed: Bank Community System Alteration/Remodel Concrete Total: Height: Individual System Repair Masonry SEP Permit# Demolition Other: Bedrooms: Water Supply: Existing: Setback: Private well - Two Party Type of Heat: Proposed: Public Total: Name of System: If this is a Commercial Project you must answer the following: Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants, employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes I No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: ❑Underground Tank °Above ground Tank Size of Propane Tank: 0 Heat Stove 0 Cook Stove 0 Woodstove 0 Fireplace Insert 0 Hot Water Tank 0 Pellet Stove 0 Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings. all property lines, tank location and size, distances from the propane tank to all property lines, buildings and septic system components, including the reserve area. Square Footage Current Proposed For Office Use Only Amount Revision Main Floor Heated EH Bld App Review: 2na Floor Heated Consistency Review: N Pr Other Heated Base fee: , a5 Mezzanine Additional Section: Heated Basement Plan Check fee: Gi 3 ', Unheated Basement State Surcharge fee: Other Unheated Pot Water Review fee: 'v P� Garage/Carport SUBTOTAL Decks 911/Rd Approach fee: Other TOTAL: $ Receipt Number: Cash;Check Number: 3 cD- ESTIMATED COST( ) Date: '7 4 •Fair market value I labor and materials foundatro o finish 'I I ( O J •lr,'1 Initials: 2 I cununrs and Berton,\car,'\I A,c.il Sctrinus\Tcmpuren'Inrcrnci files \iNiaster Permit.1ppiicatinn 12-1'. :21011ti.dnc I It �U- 6'�Lf��l C 4\44115,11"A Ur7T0?1f cvJ SIB.— A01 FZj9r,7Z M�� tcvJnw�v�� 7-112L12 V610-'IL 146 SC+t LC TD—GJ�" �g � ot7-fEn S� fl!I ii iiII��II�1l t1 I�tO Q'U 1 JQ A' /I-0 I�� I I (ztAIZA(rE GK4-C PL),�cq 1; AA,V, I/tf ill-11-0„ l+wr � r 13-01 YL r I Ml\vlq FLOOR PL,,\-1�1 SC/�Lr r /I I I I 1/ I I/ KNIGHT FIRE PROTECTION, INC. 2509 WEST 19T" STREET PORT ANGELES, WA 98363 360-417-0505 360-452-8074 FAX LICENSE NO. KNIGHFP044LK "ON GUARD 24 HOURS A DAY" JEFFERSON COUNTY DCD BOLDING PLAN REVIEW APPROVED AS SUBMITTED O APPROVED AS NOTED O REJECTED D8t9,2—L11. Reviewer' Fire Sprinkler Summary Data FILE COPY General Notes: This wet -antifreeze fire sprinkler system is being installed to provide protection for a new Boathouse/ADU being built by Allan and Nancy Vance. The Job Site is located at 512 Malamute Lane, off Highway 20, in Port Townsend. This fire sprinkler system will protect approximately 1,120 sq/ft of both heated and un-heated space. A wet- anti -freeze sprinkler system will protect the both floors. A dedicated 2" firemain will supply the fire sprinkler system. A 2" "RP" backflow assembly will be installed in the pump house. The 2" dedicated firemain will serve both the SFR (permitted seperately) and this boathouse. The water flow switch will be connected into the security system (by others). Owner: Alan and Nancy Vance Contact: Marvin Miller V: (360)385-5473 Port Townsend, Washington 98368 Job Name/Location: 512 Malamute Lane, Port Townsend, Wa. 98368 Designer/Installer: Knight Fire Protection, Inc V: (360)417-0505 F: (360)452-8074 Knighfp0441k - Level HI 2509 West 19`h Street Port Angeles, Washington 98363 Authority having Jurisdiction: Jefferson County Fire Marshal Design Standard/Occupancy: NFPA 13D — Single and Two family Dwellings (2002 edition) Hydraulic Calculations: Calculations are attached (Two head calculations — 2 design areas) Water Supply: Private well, suppling reservoir. Two 25 gpm pumps (lead/lag) providing domestic and fire sprinkler demand. Water system design by Bayview Pumps of Port Townsend. Most demanding two head area: 31.50 gpm @ 37.32 psi (includes 5 gpm domestic use) Coverage area: # Heads Head type Upper Floor 4 Reliable RFC49, %,", 165 deg concealed, res. pendant, K=4.9 Main Floor 2 Reliable RFC49,''/z", 165 deg, concealed, res. pendant, K=4.9 Total 6 Spacing: Flat ceilings: 16' x 16' maximum spacing. Piping: Entire system is 1" PVC. Supply to controls is 2" PVC pipe (provided by others). Hangers: Two hole straps for CPVC pipe, spacing not to exceed requirements of NFPA 13D. Insulation: Owner to maintain the sprinkler controls at 40 degrees to prevent freezing. "QUALITY IS REMEMBERED... LONG AFTER PRICE IS FORGOTTEN!" C%LuM ri3O Io Knighl Fim AWwlonNnjoil F,m D—notIsKPD umml'I'lII.m .lnlnn112 Gift TuaMnew pug sepog eigsoudde us %flat oouguuo+uoa ul uolpedsul seed Ism IIJOM IIV -suolsslWO 10 w011s Aug litspdooxo pseolddie as sueld -3bLLON y? r44n aj I• '�,-.X z'w'S'`k v t j''rxs }'�a�ys^'�,-[' I . � drd5�'f '� aKA-A^r�,n#rt+cy "L15s �4.n , L � St, � 4 � ii"j�tTr;' AN �s 'd4 3n '"` ' \ F �+�j,, �r t§X, -cF+4�+ 4.��Y �-a M r.t'a':1'`'r?R,w, s3tlir, I.r�}� k �• RAC MIX T,g 1�K /ri dH' ,'i�3"� Z 4. ( y Mi �lI 61Fir HANGER LEGEI A ALL THREAD ROD B I UNIVERSAL CLAMP C SWIVEL CLAMP D FLUSH SHELL E CEILING FLANGE F SIDE BEAM BRACKET ,I WEDGE ANCHOR K TRAPEEZE Y SAMMY SCREW FITTING LEGEND ST STRAP TEE 5 SOCK —IT MT MECHANICAL TEE P PIPE-0—LET SN SHAPED NIPPLE W WELD FITTING 2 WAY EARTHQUAKE BRACE 4 WAY EARTHQUAKE BRACE GENERAL NOTES REFER TO THE NFPAtt13, 2002 EDITION I. MATERIAL TO BE NEW AND UNDERWRITERS APPROVED. 2. PIPING SHALL BE PER NFPA 13. 3. EARTHQUAKE BRACING SHALL BE PER NFPA 13, A. JOINING OF PIPE AND FITTINGS, THREADED, GROOVED, PLAIN END, AND WELDED SHALL BE PER NFPA 13. 5. PIPE HANGERS AND METHOD OF HANGING TO BE PER NFPA 13. 6. PIPING DIMENSIONS ARE CENTER TO CENTER. 7. OWNER TO PROVIDE ADEQUATE HEAT TO PREVENT WATER IN PIPES FROM FREEZING IN AREAS PROTECTED BY A WET PIPE SPRINKLER 5YSTEM.(MINIMUM 40'F RECOMMENDED) 8. ALL WIRING OF ELECTRICAL DEVICES TO BE BY OTHERS. 9. PAINTING OF PIPE AND EQUIPMENT (IF REQUIRED) BY OTHERS. 10. FURRING OF PIPE AND EQUIPMENT (IF REQUIRED) BY OTHERS. APPROVALS 1 QTY ONNER/ARCNITECT N KNIGHT FIRE l TOTAL SPRINKLERS USED SYM SPRINKLER MAKE t MODEL SIZE FACTOR FINISH TEMP OUAN • Ri;u lF6t,>; �l=t �i 9 '�Z' �}. q I�ss I Va 6 SYSTEM DEMAND WATER FLOW INFO. REQUIRED PRESSURE p.s.i. STATIC PRESSURE p,s,i. AVAILABLE PRESSURE p.s.i. RESIDUAL PRESSURE p.s.i. TOTAL DEMAND g.p.m, FLOW g,P.M. HOSE g p.M. DATE TESTED DESIGN CRITERIA-2002 NFPAU13 STANDARD CLASS OF OCCUPANCY: I A GROUP: MAX $0. FT. / HEAD r2t lln DENSITY OC GPM/ SO. FT. QUALITY CONTROL BY: DATE: REVISIONS CONTRACT WITH: F1Ll 4nl 1ko ICJ-IVGq VAwL6 SIz ➢V+LAyhVTC VVlU CONTRACT NAME: AIL-4 VAA (,E- -j30AT1}0USa_- KNIGHT FIRE PROTECTION 2509 WEST 19TH STREET NE PORT ANGELES, WA 98363 (360) 417-0505 os Dw D LICENSE NO. KNIGHFP044LK r Nouns A oar DESIGNER , DATE I JOB NUMBER /—\ it FILE NAME: JoF(—,