Loading...
HomeMy WebLinkAboutBLD2008-00339 Geotechnical Report • • APPROVED STORMWATER PLAN STRATUM GROUP MAY 2 8 2009 P.O.Box 2546,Bellingham,WA 98227 Phone(360)714-9409 JEFFERSON CO February 26, 2009 E' �• el �, i�i,//j-� Allan Herold 26020 SE 154th Street MAR 2Q^ Issaquah, WA 98027 JEFFEUrn EGiJNI TED Re: Stormwater Plan and Geotechnical Review Parcel 701311021, East Quilcene Road Jefferson County, WA Dear Mr. Herold: I have reviewed the proposed development plans for your property, reviewed the geotcechnical reports for the site and reviewed and added information for the stormwater submittal to Jefferson County. The proposed development can fully disperse stormwater consistent with the Ecology (2005)BMP T5.30 with sheet flow dispersion from the driveway area consistent with Ecology (2005) BMP T5.12 and infiltration trenches for roof run off consistent with Ecology (2005) BMP T5.10. Stormwater management in this manner is consistent with the Ecology (2005) stormwater manual for Western Washington and is consistent with the geotechnical reports previously prepared for the site and is consistent with my own assessment of geologic conditions at the site. Setbacks and Slope Stability I reviewed the NTI (1993) and NTI (2002)reports regarding geology conditions at the site and I visited the site and inspected the geology conditions at the site. Conditions I observed at the site are generally consistent with the observations by NTI and I concur with the recommendations made by NTI. The initial geotechnical report NTI (1993) for the site recommended permanent structures should be located a minimum of 50 feet back from the top of the steep shoreline bluff slope. The proposed home will be located 3U feet back from the top of the steep shoreline slope. Based on my inspection of the site, it is my opinion that this distance will be protective of the home for the expected life of the home (at least 100 years). It is acceptable to have a deck within the 50-foot setback area as long as the deck is not structurally connected to the home. The proposed deck will be located no closer than 44 feet to the top of the bluff slope. The location of the deck 44 feet from the top of the bluff slope will not increase the risk to the proposed home nor will it increase the risk of slope failures on the steep shoreline bluff slope. NTI (1993) described a shallow bowl-shaped depression along the south side of the slope down towards the intermittent stream. NTI indicated that the area may represent past shallow slumping of soils, but noted that the potential slump area was not active. Past grading has taken place at this location such that soil was removed from the upper part of the bowl like area and a rockery • I February 26,2009 Parcel 701311021,Jefferson County,WA Stormwater Plan wall was constructed between the bowl area and the proposed building area. No recent movement was evident. Prior to the NTI site visit, the level area had already been graded and it is possible that past grading had placed organic rich soils with no compaction on the slope and some settlement had taken place. I also observed what may be a very old skid road across the intermittent stream valley. NTI recommended a setback from this bowl shaped area of 25 feet. The proposed home site will be located greater than 25 feet from the bowl area. The proposed building area above this are is underlain by weathered bedrock soil. Based on my observations placement of the house on the level building area as proposed will be appropriate and the home will not be subject to settlement from soils on the slope. Stormwater Management The proposed stormwater plan meets the recommendations of NTI, and is consistent with the Ecology(2005) stormwater manual adopted by Jefferson County. The proposed stormwater management for the site is for full dispersion consistent with Ecology (2005) BMPT5.30. The site will be left in greater than 65% tree and native vegetation and the amount of impervious surfaces is less than 10% of the site. The stormwater generated by the driveway area is less than the threshold requiring pretreatment and will be managed by BMP T5.12 (sheet flow). Stormwater from the roof area will be managed by BMP T5.10 (infiltration). The proposed stormwater management from the driveway area will be to allow sheet flow off of the driveway surface towards the north consistent with Ecology (2005) BMP T5.12. The following figure indicates where sheet flow dispersal should take place. Soils to the north of the driveway area consist of well drained soils with topsoil and native vegetation. The soils are Alderwood gravelly sandy loam. These soils are well drained and test pit observations on the gentle slope below the driveway to the north are consistent with these soils being well drained. Sheet flow off of the driveway to the areas indicted will not lead to any surface water flow across the site and the soils will infiltrate all runoff before any water reaches the intermittent stream located approximately 75 feet to the northeast. RECEIVED_ ORMWATER PLAN JEFFERSON COUNTY DCD k,kAY .. 3 2009 JEFFERSON la TY Stratum Group DEPT.OF CO .�� ^IT )J'OP �- SIGNATURE: File: 1.10.09 Ase 2 10 ,row--4--;.,:t9 :„...",,,—_,,,,,,,,, 1141, February 26 2009 ,aA _�' ('_ Parcel 701311021,� Jefferson County,WA F `�. till, �` ` ' 2J�� Stormwater Plan OEnserales4 o JEFF f. Z C{LDC .1 •r a termittent �, 9 '0 �e_ '�`, sµi ream <+�` TOP OF SLOPE ' _ (TYP.) t r 1 Y _�__ �� it 1 M ii V. - I F NVt'-1} �1 20'BUILDING ! )Nk Infiltration 1 �� ► SETBACK LINE ^ f Trench 4,2 _0o'r, '. SLUMP EXIST STEPS y 1 �I 1 tti AREA . •oCKERY ' 1 i SE B K .). _ �-A2 WATER STUB c J _ I 56.-6 _ 1.1 ._ _ i I I ``-.t rl1 t't}; . sss Stormwater :_ 9 `-) Y ' .-DRIVE' Ail. ) . ,• f sheet flow off T r' '. _ 1.3 7 ; driveway into —I — o-0- . 1 • --F '` native soils r, ; v i and vegetation 1 1 1 i 1 2 34' i i ROE AT r Stormwater from the roof of the proposed home should be routed to a dispersion/infiltration trench located to the northeast of the home site. Stormwater from the roof should be tight lined to the infiltration trench. The soils at the infiltration trench are well drained and the site is located upslope of native vegetation with thick(2 feet)topsoil. This site is the most appropriate for infiltration on the site as soils at this location are thick and well drained and increased water at this location will not cause any slope stability issues for the shoreline bluff slope. Directing stormwater to this area is consistent with the NTI recommendations to direct stormwater away from the steep shoreline slope and is consistent with my own opinion that this location will not cause any slope stability problems on the steep shoreline bluff slope. The stormwater generating surfaces of the roof and driveway are below the threshold level of 10,000 sf and less than the 3/4 acre threshold of land has been cleared of native vegetation for development requiring flow control (see Ecology, 200 eti the A PROV D Stratum Group STORMWATER PLAN File: .I°.°9 3 MAY 2 3 2009 JEFFERSON CO DEPT.OF CO tUNITY D COO • • February 26,2009 Parcel 701311021,Jefferson County, WA Stormwater Plan infiltration trench should be at least 10 feet long for every 700 sf of roof area and should be installed such that the dispersion pipe is level. A typical design per Ecology recommendations is presented below. • Ripe O.D. t'-0 mitt i rCh end cap o r p lug 1E4.1'7°06 oiran out w e from pipe a °a 7 o 4"or6"pert rated pipe taidflat�leoel notched a ° grade board �` tia 2"..;2'notches c; F 4 type IC B wfsolid ccn,er Clcoking) 1FJ"O.G. 3 a a rd rI ""*- 3' 4 'i a pF i is yn C fbinfl�.0 Q.�tip C F$n perdes trencht 4 4 94. lila v -clean out wya from pipe 4dd PLAN RECEW ,D pipe OD. '.AR 1 (3 2 1 f gahcanized bolts % 1'-0 / 1'•Q r1 wl D�'30' �jr(r' r��' I1(�rlllIfnJ , S WIi ,,,0'3 �0 ULi rD 1.tie`ri4 ut),")� u.J fir'i:i n ei++ r;, i �qY.l a'a' O • Q_', E6 '•'.`f .'F.. .''�. Pressure `% av treated grade 'g :^ i � �..� p a % . f :• 4"or 6"perforated ', f+ boardto `' 11, op. 9 t pipe laid flak j NOTES: tY " C 4' sup Ott pera-t I r;`� a 1.Thy trenoh shall te constructzd so clean %tir s •`� b_ '" �`'`5e a�h prevent pointdisc•harge and,hr td a q r erasrn 4, 2.Trenctr_s rnanr te plated no closer filter .Gr i -' ' '''` " than 50 feet t one anott a r.(100 feet a.br,,fbwline) "15% nr �cturf•fla controt,Vater� aslih' 3.Trenchandgrate beard must be level.A Iig n to follow contours of treatrrrent in wi J a.rvm, SECTION x x 4.Support post spacing as nag uired by J'1'!A boar) A F nV 'D STORMWATER PLAN Stratum Group File: 1.10.09 4 v1AY 2 2009 JEFFERSON CO Y DEPT.OF COMM NITY D' EL SIGNATURE: i , S February 26,2009 Parcel 701311021,Jefferson County,WA Stormwater Plan Conclusion Based on my site assessment and the investigation by NTI, it is my opinion that development of the site and the following of the stormwater plan will not cause any adverse impacts to the stability of the site or adjoining sites. Furthermore, the stormwater plan utilizing full dispersion of stormwater will not cause any significant degradation to streams or the shoreline. Stratum Group appreciates the opportunity to be of service to you. Should you have any questions please contact our office at (360) 714-9409. Sincerely yours, Stratum GroupCZC) Vg i_I. 4hN".P. Attu .:ib Dan McShane, M.S., L.E.G. �t ' ' �� Licensed Engineering Geologist +,,, .�\,t'„L °:.,�r ' .' DenicM RECEIVED MAR 1 1 r JEFFERSON COUNTY HD APPRO 'ED STORMWATER PLAN Stratum Group Ile I I o 09 MAY 2 2009 J JEFFERSON Ce Y DEPT.OF CO 0 NIT DE Lid EN SIGNATURE" i " t -11 sl rf_E - u,� :a 1 W N am -• Fi z w p ® z I CO Z p • aw Oa .= az �, ._R c. L ZZ HH • w �O " it h!IH1 �J� . � .J � � F'�,, '� a t' i. ...r, ' p H 6 ✓� ? F J ^ F aurivf"x�W �" 4� •C7 _JJ Do 11 G 40 j D CO� 8 jJ aF LLa URo ~ F- mOuiLLwa moowzcloo-~xJ uoi;eaa8a/1anq.N v accZ-YO w .1ro �0�❑-mom 'I. reappl- & z mwarnz❑"Ozz FOOzwwp a1-2q1-R r-w Z r LL I I0 O U r Z O>Q Y S❑M i pgo- w, Z2c�_ 3(0opz0 LL aal-LLy O 1_z-J0 ❑= --. - .O W_Y a=F_a rsWWQ,-W e�7 Oz J U UUr w a❑wWK C mmozo _, a� OZUW0g_ o lk C wO w rra O'W6<0w �' mwoioZ= OjU rO,m aOLL, m 1 p�<D WN_{ 50. _ wozO�X Jm l 1 wa)wU0o VaOa❑ �`.'0r 'I J U' z W U m❑ z W O•K W a LL r(r 00 > ` _ ,y z Q-❑ Q a p k O F J� ❑W N m K QW Za J rJ Z \1LLLL❑ zVK0KZUU > cli 6 W °oI- 0, r C °Zm' \C o < aJWo s \ .I/ S ¢ 3xm - w Z \00 s -, wm i 0zFw caOwFaaww i c aJr 8WWa NoK¢ S wQ \ \ ill — w \ . y a: z ,� ,.. a VV o = 4 g acWia a FraHH ' 0J A. ❑ pQ6w OI-`tnz J is rr }WZJ ❑aw r,OwS .I co LI W W q V w y LLO q W K?w)2S w(-)is FQ- Z _• m J ❑> qq ❑ a W ZK, rr,-Z Li)R 1 c Ja O_J W mmS,.�zwwE H =1i) P.,-J,a �Jra�axpw w w u I <n0 6)yzW aItm0,-zLLx0 _ ZW 1I U Oz Czww moo Kw1-0 L,1 Zcr.) zmm� w>¢�p�m�r U ....� z. )• II J W m OU w O C O 0 m r W»0 Q ,I r� �awW NyOw�OOOa d Q CO - Na co 0 2aYam.-WUN Ct u' aJ co iii oO EcE}iviE3 } ) zm <oww Wg3N UU,_m,ceY Z Q b �jI�11 J o% w L(>a p a�O O W.1 2 s o A_J 05 Ew,i )- -.tom. -o00 J U❑ OO , ZNwmUJz aN m �u a mzowtw=rnz on ¢(21-0 �aOwI-�Jw wa fiLI!,`k hn 21YL: 3 R. >K.S wWNW ZUc'zZ �(�'1� 1 V 4.i�l:�i a JL 7 U am-N QF- J- J ce W N ❑C Y w N K 28 °< La'‘) --, a�M0ra>0�W , Z J ZOO }m a W Z O LL LL o N a❑a- 0 w I <<• Orwvwwo <,w, OYz? UOie �� � 1 'n•� � �(��'l l ( Dl)D �W �m�z ow�xoT(-900iawomQ00 J 1a6aAanneNt. ., c t )� �IiJ • go xi--xo wrcNDaugwzce i. am amrnLL ra❑❑omrnw i m O. 0 a l ' w a Herold Residence sF 3862EOui|oeneRd Pance|#7U1311U21 Pw MLA00'00383 om pnSTJ SH, LOT COVERAGE&IMPERVIOUS SURFACE \,/ rm REF /Mpxovemsmr xuF/ LoTcov Ex/o/ /mpEnv wEvv/�p�xv rO '/,` PR( DIS , PROPOSED NEW RESIDENCE 2224 o o o ov/ z PROPOSED BASEMENT �nn1 1591 o 1591 �� m, n pnnposEooECxs1o^nFps*xoE- n*a 643 o o*n `./' SE) 4 DRIVEWAY mWALKS /000 o u 1558 ro uw' InnALs 6016 azo* n nrnx ER( WE -TOP'-OF BEUFF- w00%uoo'oo''vv � / • • Herold Residence Infiltration Trench Details 3962 E Quilcene Rd Parcel#701311021 M LA08-00363 pipe F.D. 1%0 1`-0 rain min ,..,end cap or plug IFl„c o,,._-clear!outwr from pipe a a °a 99,, 0 -'4"orb"perfaratd pipe la.idfiatilevel ched _ not p 6- grade board Ea `a 215c 2'notches v, 9 .,.type I C B w//olid cover(Ice king) iS'O.C. A 1 a a r[ r+l- a influent pip= (maxdesign �qp fiow .0.8CF$pertr'ench) 7. clean outw'e from pipe oa a PLAN ""'":: �® , 10 feet of length required per 700 kl; 0. . square feet of roof area ' �r'�`"�'' "' � '`f xp`P,r 0 1373 /✓ ci i pipe C.G. galvanized bolts 1 0 j 1' 0 00 ,I--7T SFr'' . NOTES: b 3' '• " 2'x12" `1' c,r, r finis.o r n•;9 h4h :i 1.The tprah stall tp is c harge an sr) ` ,,.; r.•b• a '£ ` er s prevent point discharge andk�r pressure �' ���/�:��� a a' ''VI"' 9 •'• erosion. treated grade . p n n , i,.4"ore'pert ri d 2 Trenctes lie be pI?e ed no clo r bJal'd D c?.,...,4pips Idid fiat than50 itr_t ID one.Krbiher. 10lj fit n $' a a a? 4"Y.4 support pert t r 3 Trench nd gr.--,de board roust be. �a C1�3J1{-�,,•�, tires) Hel Align n_:folimoonvur$ofsiV. tp 4 a S ,. 4.Support post spacings rxauir d by d a A. ' 9Dilc.orditinstoensufegrdeboard fitter brie �'' ` remains Mosel. %15% rrrixfa-r fl cw ccritrol eater ganity treatment in rural aree . rr�� SECTION A-A mike i p,� r-1Pri�, JEFr�nt,nil! 0�p,IT n E! ',,.l;a t?,,!?IY