Loading...
HomeMy WebLinkAboutBLD2009-00205 UILDING PERMIT APPLICASN ML Review y 224 T Type: I Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD09-00205 Received Date: 7/7/2009 SITE ADDRESS: LYLUS LN PORT HADLOCK, 98339 OWNER: DONALD L MYERS PHONE: 360-379-9964 CRYSTAL D MYERS PO BOX 615 PORT HADLOCK WA 98339-0615 MELWOOD TERRACE SUBDIVISION: Block: Lot: 3 PARCEL NUMBER: 972000003 Section: 1 Township: 29 N Range: 01 W CONTRACTOR: PEARCE PENINSULA BUILDERS PHONE: (360)379-4740 184 10TH AVE PORT HADLOCK WA 98339 Contractor's License PEARCPB141P8 Expires 6/19/2011 REPRESENTATIVE: DAN PEARCE PHONE: 360-379-4740 184 10TH AVE PORT HADLOCK WA 98339 PROJECT DESCRIPTIOP NEW POLE BLDG/GARAGE - UNHTD, NO PLMB TYPE OF WORK GAR SQUARE FOOTAGE: TYPE OF IMP NEW VALUATION 30,028.00 MAIN: CODE EDITION: 2006 ADD'L: HEAT TYPE: UH OCCUPANCY: HEAT BASE: HEAT TYPE OCCUPANCY: UNHEATED: #OF STORIES: CONST TYPE: OTHER: GARAGE: 1328 SHORELINE: CONST TYPE: SETBACK: DECK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: 0 Exist: 0 Prop: 0 Prop: 0 Total: 0 0- Routing Date: Type Amount Paid By: Date: Receipt: AP ' Permit $451.85 LYK 07/07/09 108727 Plan Check $293.70 LYK 07/07/09 108727 AUG-Db 29 State Building Code $4.50 LYK 07/07/09 108727 Total: $750.05 Jefferson County PlanninG & Building Department Jefferson County Building Clksion Permit Null,: BLD09-00205 Applicant:BUILDING PERMIT INSPECTION APPROVALS \pplicable Code: MYERS 006International Building Codes To schedule inspections, call (360)379-4455 ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Setbacks /H M Erosion Control I Post Holes Straps(hold downs) Framing I _, Blocking Drywell/Alt Drainage Address Posted FINAL INSPECTION 3- ���� FINAL INS ECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR • CONDITIONS for Building Permit# :BLD09-00205 • 1.) DESIGN CRITERIA FOR SPLASHBLOCKS: A VEGETATED FLOWPATH OF AT LEAST 50 FEET SHOULD BE MAINTAINED BETWEEN THE DISCHARGE POINT AND ANY PROPERTY LINE, STRUCTURE, STEEP SLOPE, STREAM, WETLAND, LAKE, OR OTHER IMPERVIOUS SURFACE. SENSITIVE AREA BUFFERS MAY COUNT TOWARD FLOWPATH LENGTHS. A MAXIMUM OF 700 SQUARE FEET OF ROOF AREA MAY DRAIN TO EACH SPLASH BLOCK. A SPLASHBLOCK OR A PAD OF CRUSHED ROCK (2 FEET WIDE BY 3 FEET LONG BY 6 INCHES DEEP) SHOULD BE PLACED AT EACH DOWNSPOUT DISCHARGE POINT. NO EROSION OR FLOODING OF DOWNSTREAM PROPERTIES MAY RESULT. FOR SITES WITH SEPTIC SYSTEMS, THE DISCHARGE POINT MUST BE DOWNSLOPE OF THE PRIMARY AND RESERVE DRAINFILED AREAS. 2.) CONSTRUCTION ENTRANCES SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM COMPACTED SUBGRADE. QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. (BMP C105, 2005 DOE STORMWATER MANUAL). ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED BY SHOVELING OR STREET SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON STIE. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD, WHICH END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. UPON PROJECT COMPLETION AND SITE STABILIZATION, ALL CONSTRUCTION ACCESSES INTENDED AS PERMANENT ACCESS FOR MAINTENANCE SHALL BE PERMANENTLY STABILIZED. 3.) To help prevent seawater from intruding landward into underground aquifers, all new development activity on Marrowstone Island, Indian Island and within 1/4 mile of any marine shoreline shall be required to infiltrate all stormwater runoff onsite. 4.) The property owner shall comply with Water Conservation Measures (per list maintained by the UDC Administrator). 5.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin. 6.) Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard. 7.) Not more than 2 unlicensed veh shall be stored on any lot unless totally ned from view of neighboring dwelling and rights-of-way. Such screening shall mall applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Chapter 18.30 JCC. Outdoor storage of 3 or more junk motor vehicles is prohibited except in those districts where specified as an automobile wrecking yard or junk (or salvage) yard and allowed as a permitted use in Table 3-1 or Chapter 18.18 JCC, and such storage shall meet the requirements of JCC 18.20.100, Automobile wrecking yards and junk (or salvage) yards. In no case, shall any such junk motor vehicles be stored in a critical area. 8.) The road approach permit(RAP09-0045) must be inspected and finaled by the Jefferson County Department of Public Works prior to the final inspection/certificate of occupancy of this residence. Contact Terry Duff, Department of Public Works at 360-385-9159 for the final road approach inspection. 9.) Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc. 10.) The building height is not to exceed 35 feet. 11.) Minimum setback from Lylus Lane and Oak Bay Road rights-of-way shall be 20 feet. Minimum side yard setbacks shall be 5 feet. 12.) Exterior lighting for residential uses shall not exceed twenty feet(20') in height from the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged. 13.) Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way. • • �4�. O10'''1''''''-' N `,O�`2" JEFFERSON COUNTY r, ' DEPARTMENT OF COMMUNITY DEVELOPMENT '? '4 621 Sheridan Street • Port Townsend •Washington 98368 �$ 360/379-4450 • 360/379-4451 Fax .q� www.co.jefferson.wa.us/commdevelopment Master Permit Application MLA: - ' Project Description(include separate sheets as necessary): ,0� rn 1 Mr3 Tax Parcel Number: 9 7 Z oco30 3 Property Size: 7 7C(.D (acres/square feet) Site Address and/or Directions to Property: L_m S L Property Owner(s)of Record: DON tr• /71 y'/-/2,5 Telephone: 36C 3 2'i `l6' Fax: email: till Address: ' L i L U 5 LA/ _ Pr:. 1-1q r)r;cc /S Applicant/Agent(if different from owner): ]..),4-J./ PL=19R cc Telephone: ?60 3 7/-17 Fax: 4j41,ev1 E email: / S/30 0 44,2rnlC H(tgvyvC. Mailing Address: /ecf /0 r-ff /tit lu' T N4OLOCe. 1,4_ F, �3, What kind of Permit?(Check each box that applies 0 Lot or Road Segregation ABuilding 0 Critical Areas Stewardship Plan ❑ Demolition Permit 0 Variance(Minor, Major or Reas ble_Ecpno Use) ❑ Single Family Die Garage Attache /Detached 0 Conditional Use[C(a),C(d),or C] ❑ Manufactured Home 0 Modular 0 Discretionary"D"or Unnamed Use Classification ❑ Commercial* ❑Special Use(Essential Public Facilities)** ❑ Change of Use ❑ Boundary Line Adjustment ❑ Address 0 Road Approach 0 Short Plat** ❑ Home Business 0 Cottage Industry 0 Binding Site Plan** ❑ Propane ❑ Long Plat** ❑ Sign • 0 Planned Rural Residential Development(PRRD)/Amendments** ❑Allowed"Yes"Use Consistency Analysis 0 Plat'Vacation/Alteration** ❑ Stormwater Management ❑ Shoreline Master Program Exemption/Permit Revisions** ❑ Site Plan Approval Advance Determination(SPAAD)* 0 Shoreline Management Substantial Development** ❑Temporary Use 0 Shoreline Management Variance ❑Wireless Telecommunication* 0 Comprehensive Plan/UDC/Land Use District Map Amendment ❑ Forest Practices Act/Release of Six-Year Moratorium ❑Jefferson County Shoreline Master Program Amendment *May require a Pre—Application Conference 0 Tree Vegetation Request **Requires a Pre-Application Conference Please identify any other local,state or federal permits required for this proposal, if known: DESIGNATION OF AGENT I hereby designate )'� c c t.il"E' to act as my agent in matters relating to this application for permit(s). OWNER SIGNATURE , f Date: By signing this application form,the owner/agent attests that the information provided herein,and in any attachments,is true and correct to the best of his,her or its knowledge. Any material falsehood or any omission of a material fad made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the application that he ants prior notice. / Signature: Date: v r The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential'take"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non-transferable respo ' ( for adhering to and complying with the ESA. The Applicant has read this disclaimer and signs and dates it below. Signature: � Date: 7 — 6 • 110 BUILDER STATEMENT The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be-assun*g the responsibility of the General Contractor for the proposed project- / C� Signature: . ail , Date: .l — v — / NERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX: i/r2 cF held/Add L4 811i l [Dc,__S (3 ) 3i -17-10 (360)37Y Y7Y cJ c1 MAILING ADDRESS: / /D "71 tip EMAIL: pcpopVuReNG[7 cs4 Cl n L CONTRACTOR'S LICENSE �WAINS ����6� �� NUMBER: Pff1 lz C P r3 J c ( /v n$ , NUMBER ARCHITECT/ENGINEER: Pi ittAl iiot /Ln/A 5 PHONE (56,7) 263 _0Y5,3 FAX:(5$3)L6.6 , 7/0-L MAILING ADDRESS: Z,Z I S S.N,f4 e�T' cj9E' C'9Ndi 0R. ?70l 3 EMAIL Xrolect Type: Fram ype: Bathrooms: Shoreline: Type of Sewage Disposal: New X.Wood Existing: I'VLNL (j ❑ Sewer Al(J ❑ Addition ❑ Steel Proposed: Bank El Community System 0 Alteration/Remodel ❑ Concrete Total: _ Height: 0 Individual System O Repair 0 Masonry`, SEP Permit# O Demolition ❑ Other: v Bedrooms: / Water Supply: D Disc�- t;,q Existing: v Setback: 0 Private well ❑ Two Party Type of He t: J Proposed: ❑ Public l 9ln Total: Name of System:Q&R If this is a Commercial Project you must answer the following: Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants,employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: 1 Underground Tank 1 Above ground Tank Size of Propane Tank: i Heat Stove 1 Cook Stove 1 Woodstove i Fireplace Insert 1 Hot Water Tank i Pellet Stove i Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines, tank location and size,distances from the propane tank to all property lines,buildings and septic system components, including the reserve area. Square Footage Current Proposed 'FOr Office Use.001y _ ArielAet .6vIl'j : :4 e Main Floor Heated EH Bld App Review: N%tom DSC i Floor Heated Consistency Review: Other Heated Base fee: /15( Mezzanine Additional Section: �i--- Heated Basement Plan Check fee: O(q r70 Unheated Basement State Surcharge fee: 5t3 Other Unheated Pot Water Review fee: t3o -RH5 Garage/Carport 2'612-ci CP SUBTOTAL Decks 911/Rd Approach fee: Afpl IEb 442-Pt Other TOTAL: $ ,�' J C/ Receipt Number: 1 U g1Z1 Cash/Check Number: G31 ESTIMATED COST(REQU Date: .Fair market value of al or and materials foundation to finis -w ' C) O LS _co Initials: COLUMN SIZE & GRADE WITH CONCRETE BACKFILL SCHEDULE NOTE: C- ALL CONCRETE BACKFILL DEPTHS 6x6 HFIR /2 W/ C BASED ON PLACEMENT INTO (B) 24" DIA x 4'-6" DEEP UNDISTURBED NATIVE SOIL. I 6x6 HFIR #2 W/ V 24" DIA x 5'-O" DEEP (V O (D) 6x6 HFIR #1 W/ C._,24" DIA x 5'-O" DEEP n6x6 HFIR SEL STR W/ 24" DIA x 4'-6" DEEP . 6x6 HFIR SEL STR W/ 24" DIA x 5'-0" DEEP n 6x8 HFIR SEL STR W/ 24" DIA x 4'-6" DEEP 6x8 HFIR SEL STR W/ 24" DIA x 5'-O" DEEP 15' EAVE 13' EAVE HEIGHT HEIGHT % 13'-9" c_ 12'—O" c_ 12'—O" T. I 1 VI 1 1 N 1 1 i 7.) 0 '-' -/ 0 (B)\ qE0' 0 0 0 I I 1 ��-+ �I (D) (D) I/®+- (B) 1/ ©-�0-i , 0 1 N 0 M o I O O I 00 I I O O N /--]\ (B) I ®-I--- of (D) 1\®l-- c3''t--+- I U o / 0 I O Kq) /-\ /-N FlOi o 1 0 ® I I 1 \ \ al I 1Ox9 OH DR \tr 1Ox9 OH DR - / 1 x O 1 0 1 m CO 0 / p / NM� \ \ I — I -/ 12x13 OH DR - � 14'-O" / 1 1 '-9" / 12'-O" / 37'-9" 1 FOUNDATION/FLOOR PLAN of 5 M & W BUILDING SUPPLY PEARCE PENINSULA BUILDERS for 1 _ \A 1.• Sh- CUSTOM POLE BUILDINGS MEYER C 41 LYLUS LANE BUILDING SUPPLY � 40' WIDE x 14' LONG x 15' EAVE PORT HADLOCK, WASHINGTON & '��I�}��`'1'W Asc litA S W/ 1-32' W x 24' L x 13' EAVE COUNTY: JEFFERSON 22175 S. HWY. 99E L • CANBY, OREGON 97013 ,.- ROOF LOAD LIVE 25 PSF ENGINEERS DESIGN RESPONSIBILITIES ARE LIMITED EXCLUSIVELY TO 503 263-6953 gyp+ It oy THOSE DOCUMENTS BEARING HIS SEAL AND SIGNATURE. ANY ALTER- ( —{/ DEAD LOAD, 3 PSF ATIDNS TO THESE DOCUMENTS OR THE PHYSICAL STRUCTURE BY ANY 1503� 266-7102 (FAX) j..,` WIND LOAD: 85 MPH EXP: C PERSONS OR AGENCY SHALL VOID SAID DOCUMENTS AND RELIEVE ENGR OF t' DESIGN RESPONSIBILITY, AND MAY CREATE LIABILITY ISSUE FOR THEMSELVES SCALE NONE 1 �� SEISMIC ZONE, D DRAWINGS ARE FOR STRUCTURAL COMPLIANCE ONLY. THEY ARE NOT TO �O �� 37213�p tS F❑UNDATI❑N PRESSURE 1500 PSF BE CONSTRUED AS HAVING BEEN PREPARED FOR BUILDING USE, OCCUPANCY GLC/GP 6/25/O9 �+I �1� AND/OR FIRE & LIFE-SAFETY REQUIREMENTS OF LOCAL CODES OR J LAT, SOIL BEARING 150 PSF AGENCIES. SLAB & HAIRPINS SHOWN FOR CONSTRAINMENT ONLY, DESIGN s`SJONAL�� BUILDING DESIGN: 2006 I.B.C. MIX, THICKNESS, CJ' s, & REINFORCEMENT BY OTHERS. THIS STRUCTURE HAS NOT BEEN DESIGNED FOR USE WITH INTERIOR FINISH CLOSED BUILDING MATERIALS SUBJECT TO DAMAGE OR FAILURE DUE TO LATERAL MOVEMENT KIT MW09166 J,. m D 4 APPROVE z 21 49 SITE PLAN m AUG 2 6 2009 JEFFERSON COUNTY DEPT.OF COU .__ _.-, SIGNATURE;.� �ANi XI f} n m - r ,00- •, I;C:1:v _ci Ai fJ a� � o A r C, 11 Iv 0,41517 y Cl) ��� Qu!A'fa • A OM 4- 1 CL N `J 42 › , v ----3, Q t •.et • • �1 p =z. CI m i • . W r � w 1...' .... .26.\ Cb 46 1 / . i j N z 1 � m Hi • v ; _ ,l i m _ �. .- ,-L�t ..�........ . ..r J\ _ h � 0 (\ ) r- � z • m + '- c e rn P 73 COM . � - , I r A c el) Ni ° I `� ' 1 g. .` z c-2 < . m