Loading...
HomeMy WebLinkAboutBLD2008-00187 Jefferson County Building D ion Permit Numb!.- BLD08-00187 Applicant: VANDEWEGHE BUILDING PERMIT INSPECTION APPROVALS applicable Code: 2006 International Building Codes To schedule inspections, call (360)379-4455 no later than 7:00 AM the day of the inspection. Requests received after 7:00 AM will not be scheduled for that day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Setbacks Erosion Control Foundation Footing Footing Drains Foundation Stem Wall Under Floor Framing Straps(hold downs) Ext. Shear Wall Nailing Rough-in Plumbing Framing cling Airseal Insulation: Walls Insulation: Floors Insulation: Ceiling Int. Shear Wall Nailing IWallboard Nailing G : later Gas Line: EggriOf ,rooane._Iank HootLChimney Clearance Drywell/Alt Drainage jef C 1.YYL h c(l 4 1Address Posted /. a-Mk -I ncn : nor it)crY L FINAL INSPECTION FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR • • CONDITIONS for Building Permit# :BLD08-00187 1.) 2005 DOE STORMWATER MANUAL DRYWELL DESIGN CRITERIA ALL INFILTRATION SYSTEMS SHOULD BE AT LEAST 10 FEET FROM ANY STRUCTURE, PROPERTY LINE, OR SENSITIVE AREA. FOR SITE WITH SEPTIC SYSTEMS, INFILTRATION SYS--EMS MUST BE DOWNGRADIENT OF THE DRAINFIELD UNLESS THE SITE TOPOGRAPHY CLEARLY PROHIBITS SUBSURFACE FLOWS FROM INTERSECTING THE DRAINFIELD. DRYWELL BOTTOMS MUST BE A MINIMUM OF 1 FOOT ABOVE SEASONAL HIGH GROUNDWATER LEVEL OR IMPERMEABLE SOIL LAYERS. EACH DRYWELL MAY SERVE UP TO 1000 SQUARE FEET OF IMPERVIOUS SURFACE FOR EITHER MEDIUM SANDS OR COURSE SANDS. TYPICALLY DRYWELLS ARE 48 INCHES IN DIAMETER (MINIMUM)AND HAVE A DEPTH OF 5 FEET (4 FEET OF GRAVEL AND 1 FOOT OF SUITABLE COVER MATERIAL). FILTER FABRIC (GEOTEXTILE) MUST BE PLACED ON TOP OF THE DRAIN ROCK AND ON TRENCH OR DRYWELL SIDES PRIOR TO BACKFILLING. SPACING BETWEEN DRYWELLS MUST BE A MINIMUM OF 4 FEET. 2.) CONSTRUCTION ENTRANCES SHALL BE STABILIZED WHEREVER TRAFFIC WILL BE LEAVING A CONSTRUCTION SITE AND TRAVELING ON PAVED ROADS OR OTHER PAVED AREAS WITHIN 1,000 FEET OF THE SITE. THE ENTRANCE SHALL BE CONSTRUCTED ON A FIRM COMPACTED SUBGRADE. QUARRY SPALLS (OR HOG FUEL) SHALL BE ADDED IF THE PAD IS NO LONGER IN ACCORDANCE WITH THE SPECIFICATIONS. (BMP C105, 2005 DOE STORMWATER MANUAL). ANY SEDIMENT THAT IS TRACKED ONTO PAVEMENT SHALL BE REMOVED BY SHOVELING OR STREET SWEEPING. THE SEDIMENT COLLECTED BY SWEEPING SHALL BE REMOVED OR STABILIZED ON STIE. ANY QUARRY SPALLS THAT ARE LOOSENED FROM THE PAD, WHICH END UP ON THE ROADWAY SHALL BE REMOVED IMMEDIATELY. UPON PROJECT COMPLETION AND SITE STABILIZATION, ALL CONSTRUCTION ACCESSES INTENDED AS PERMANENT ACCESS FOR MAINTENANCE SHALL BE PERMANENTLY STABILIZED. 3 ) A"Construction Drawing" Flood Elevation Certificate was prepared by a licensed surveyor and submitted with the application. The Certificate identified the base flood elevation of 202 feet. The lowest floor of the structure is required to be elevated at least one (1) foot above base flood elevation or 203 feet. PRIOR TO FINAL BUILDING INSPECTION, PROPONENT SHALL PROVIDE THE DEPARTMENT WITH AN ORIGINAL "FINISHED" CONSTRUCTION" FLOOD ELEVATION CERTIFICATE THAT HAS BEEN VERIFIED BY A LAND SURVEYOR, ENGINEER, OR ARCHITECT AUTHORIZED BY LAW TO CERTIFY ELEVATION INFORMATION IN THE STATE OF 'VVASHINGTON. 4.) Flood hazard reduction measures are to be used as required by the Jefferson County Flood Damage Prevention Ordinance 07-0515-06 (Jefferson County Code Chapter 15.15). • • 5.) Construction Materials and Methods of Construction to Reduce Flood Hazard (i) All new construction and substantial improvements shall be constructed with materials and utility equipment resistant to flood damage. (ii) All new construction and substantial improvements shall be constructed using methods and practices that minimize flood damage. (iii) Electrical, heating, ventilation, plumbing, and air-conditioning equipment and other service facilities shall be designed and/or otherwise elevated or located so as to prevent water from entering or accumulating within the components during conditions of flooding. Locating such equipment below the base flood elevation may cause annual flood insurance premiums to be increased. 6.) New construction and substantial improvement of any residential structure shall have the lowest floor, including basement, elevated one foot or more above the base flood elevation (BFE). 7.) Fully enclosed areas below the lowest floor that are subject to flooding are prohibited unless designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwater. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following criteria: a. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottom of all openings shall be no higher than one foot above grade. c. Openings may be equipt with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwater. 8.) Critical Aquifer Recharge Areas may require special protection measures to mitigate water quality degradation. The submitted proposal does not require additional aquifer protection measures. However, during construction the project shall follow the Best Management Practices (BMPs) and facility design standards as identified and defined in the Stormwater Management Manual for the Puget Sound Basin. 9.) The project shall comply with Construction Stormwater Pollution Prevention (SWPP) Elements#1 through#12 of the Department of Ecology's Stormwater Management Manual for Western Washington to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 10.) Outdoor residential storage shall be maintained in an orderly manner and shall create no fire, safety, health or sanitary hazard. 11.) Not more than 2 unlicensed vehicles shall be stored on any lot unless totally screened from view of neighboring dwellings and rights-of-way. Such screening shall meet all applicable performance and development standards specific to the district in which the storage is kept, and shall be in keeping with the character of the area. Screening shall meet the requirements of Chapter 18.30 JCC. Outdoor storage of 3 or more junk motor vehicles is prohibited except in those districts where specified as an autormobile wrecking yard or junk (or salvage) yard and allowed as a permitted use in Table 3-1 or Chapter 18.18 JCC, and such storage shall meet the requriements of JCC 18.20.100, Automobile wrecking yards and junk (or salvage) yards. In no case, shall any such junk motor vehicles be stored in a critical area. 12.) A minimum of two (2) on-site parking spaces shall be provided for the single family residence. 13.) Maximum lot coverage is not to exceed 25%. Lot coverage is defined as amount of impervious surface which includes roof tops, driveways, concrete, etc. 14.) Exterior lighting for residential us1all not exceed twenty feet(20') in height the finished grade, excepting when such lighting is an integral part of a building or structure. Ground level lighting is encouraged. 15.) Lighting fixtures shall be designed and hooded to prevent the light source from being directly visible from outside the boundaries of the property. The intensity or brightness of all lighting, during construction and after project completion shall not adversely affect the use of surrounding properties or adjoining rights-of-way. 16.) The building height is not to exceed 35 feet. , • , ,0 dow Ail gi:1, io • . _. II ... • S'10.•,. bf) OP 4 , . 0_..., P,, ..... ._ Z47-i"'-' c=.cV --...,., „ • ,,- •-' = —) czs u) c....._,.„ t .••-• 0, cr o . r... . • f.:.P' ts. < .:, 71 kr,1-5- oc 0 !.........1 ....,..... .71- vo cz 0 0 a) czN .---- N . cu ,....4 fa, fa, 6r o tIJ •• t;1 t+-1 C./) 0 fD' CI) Cc2 7:3 (-) '••-' N CO C) .._ E 0. o _L-, 5 " a) cs,, •,--, -0 _a ...o _ --, cn a\ a) >'-' •8 -0 0 - 0 cr) a s5.-1,3 0 c#S1 r:4 pEL II Cl., ,- ct lol # otr x 0 --....„ z i ...: . AFFERSO:t4 LutiNa ...., . ... .... 8 -c a. 1 1 11 Tr) --------------,---'- ..1.)-' o• a) reserve drain field . — t a) .--, a) es . "Li •:1- ii-) t,--2, -4 c c c c c a) CNI cct 0 •1.1 et9 1, CI ' .'• '71 CD \ 00 0 goioa __. __.... ( 5 1- b.!) 0 cn a) -I 3 ouomsal 29' ic.Kns oml i. -7 — 0 L 0 / 'II-- i 200j .13s 9gg C 6'— 71' ,. 1 134.49 \\ 1 0 cu o u •,-, En 773 7:3 • • rn 0 3 o o -o closet 4 o a " a 8 . ¢'.s� O a, k o ) I a) bn 0 • ________:— I CI c. o ti o N t�r a II c) K\N-------_ \ _ �.� L..L.J o cn o O 1 A U s, 41¢gON c' JEFFERSOIUNTY 'IA DEPARTMENT OF COMMUNITY DEVELOPMENT `'' v 621 Sheridan Street • Port Townsend •Washington 98368 '� — 20 08 360/379-4450 • 360/379-4451 Fax �q c5" www.co.jefferson.wa.us/commdevelopment .S -NOr 1 Master Permit Application MLA: 06 - cal 1 Project Description(include separate sheets as necessary): A."t.vi toc.`.�.-ti► }c,..: At ..if .si: S:c°+�.4rls: ( `55/_ ;t s. �� I r Tax Parcel Property c1 . .1t Number: 99 S.`f..C%(k `•y Size: " . ,µ quare feet) Site Address and/or Directions to Property: / j(\ci1{<_0 et} okt s;vr ., j(..1.,,<,.„, cc. ,r} U1. i-1 S K\ v• L i, CO—.ri76-tc;�1 c J '1C c .z.. / vlA $n QV, G : 4.. `'{ 1 r i..; t`►c. C'2�: .�0'�'+Nc Lr� ltx. Property Owner(s)of Record: 1cinzr1 L„\ vltit2ovtutiAL Telephone: C3 6 ) �t!S c>}5 G t ++ Fax: 1 email: 5 "?cl,,c', 11 �' vu 1 S}<tv ie S. t L..., Mailing Address: 3'-l-5 k,&Yg2.iiL<llt. 'or,4%!._ 4',,:.1c,2,4 i.:JA 953 f6 Applicant/Agent(if different from owner): Telephone: Fax: email: Mailing Address: What kind of Permit?(Check each box that applies /Building 0 Variance(Minor, Major or Reasonable Economic Use) ❑ Demolition Permit 0 Conditional Use[C(a), C(d),or C]** /Single Family 0 Garage Attached/Detached 0 Discretionary"D"or Unnamed Use Classification ❑ Manufactured Home 0 Modular 0 Special Use(Essential Public Facilities)** ❑ Commercial* 0 Boundary Line Adjustment ❑ Change of Use 0 Short Plat** ❑ Address 0 Road Approach 0 Binding Site Plan** 0 Home Business 0 Cottagelndustry 0 Long Plat** ❑ Propane 0 Planned Rural Residential Development(PRRD)/Amendments** ❑ Sign 0 Plat Vacation/Alteration** ❑Allowed "Yes"Use Consistency Analysis 0 Shoreline Master Program Exemption/Permit Revisions** ❑ Stormwater Management 0 Shoreline Management Substantial Development** ❑ Site Plan Approval Advance Determination (SPAAD)* 0 Shoreline Management Variance ❑Temporary Use 0 Comprehensive Plan/UDC/Land Use District Map Amendment ❑Wireless Telecommunication* 0 Jefferson County Shoreline Master Program Amendment ❑ Forest Practices Act/Release of Six-Year Moratorium 0 Tree Vegetaion Request *May require a Pre—Application Conference **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: DESIGNATION OF AGENT I hereby designate to act as my agent in matters relating to this application for permit(s). OWNER SIGNATURE Date: By signing this application form,the owner/agent attests that the information provided herein,and in any attachments,is true and correct to the best of his,her or it's knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the appliR ation that he r she wants prior notice. Signature: /.\ _ Date: Ca�`,�� fi �+ The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential"take"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non-transfehable responsibility for adhering to and complying with the ESA. The Applicant has read this disclaims and signs and dates it below. Signature: j11 i2 lam'_.---" Date: Li :11 '.2 6 }t CC, 1 .. / G:\PermitCenter\###FORMS###\DRD FORMS\Master Permit Application 12-19-2006.doc • BUILDER STATEMENT IIII The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be assuming the responsibility of the General Contractor for the proposed project. Signature: :v.-'a *--, i.„, -- Date: 'tt .t t�• A in ", GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: Fax: ( ) ( ) MAILING ADDRESS: EMAIL: CONTRACTOR'S LICENSE WAINS NUMBER: NUMBER ARCHITECT/ENGINEER: t-rI� _%L }� 1� PHONE ( =-,{,, ) ,,<s,, i icl. ; FAX: ( ) MAILING ADDRESS: EMAIL Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal: 1W New Jf' Wood Existing: ❑ Sewer Addition ❑ Steel Proposed: Bank ❑ Community System ❑ Alteration/Remodel ❑ Concrete Total: .,Z Height: V Individual System r� ❑ Repair ❑ Masonry SEP Permit# ''; ) -- J' Demolition ❑ Other: Bedrooms: Water Supply: Existing: r:•? Setback: ❑ Private well ❑ Two Party Type of Heat: Proposed: X Public �1�t_Ai,%� Total: Name of System: ev® If this is a Commercial Project you must answer the following: Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants, employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: i Underground Tank i Above ground Tank Size of Propane Tank: i Heat Stove i Cook Stove i Woodstove i Fireplace Insert i Hot Water Tank i Pellet Stove I Other Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines, tank location and size, distances from the propane tank to all property lines, buildings and septic system components, including the reserve area. Square Footage Current Proposed For Office Use Only Amount Revision Main Floor Heated 09 4a � �EH Bid App Review: 2nd Floor Heated Consistency Review: Sa tlbol.al 157.cL Other Heated Base fee: .�-- l a']. '15 Mezzanine i.,, Additional Section: �,. s: „ Heated Basement /. Plan Check fee: 41 .U4 Unheated Basement ' - ` ,20�8 State Surcharge fee: 4. 5(D Other Unheated Pot Water Review fee: Tv R5. CO Garage/Carport ��%, �'`'t' SUBTOTAL 15Ai .ac\ Decks 911/Rd Approach fee: t 5 OT Other Co v2r z P,,r ) SCE a01S.40 TOTAL: $ l(c76.5 al Receipt Number: Cl'7 3 45 Cash/Check Number: r r' 1417 ESTIMATED COST(REQUIRED) Date: 5 �� •Fair market value of all labor and materials foundatio a im>slr� 5!, 360, 00 j $ .)Initials. G:\PermitCenter\###FORMS###\DRD FORMS\Master Permit Application 12-19-2006.doc O 1