Loading...
HomeMy WebLinkAboutSEP2012-00093 i 1 Jefferson County Department of Community Development el _, i 621 Sheridan St,Port Townsend WA 98368,(360)379-4450 �iA. �,�WA. �A ��.. SEPTIC PERMIT APPLICATION 4:ff,'. lit! PROPERTY OWNER Zak i4 Ater e k t. l tver x o uXge•�' ' >:: : <fi JEFFERSON COUNTY PUBLIC HEALTH t'' '" , 615 Sheridan Street*Port Townsend•Washington *98368 www.jeffersoncountypublichealth.org one •1- -•. .; ax •1- ,_. . ON-SITE SEWAGE DISPOSAL PERMIT PERMIT#: SEP12-00093 Date Received: 08/10/12 SITE ADDRESS: Date Issued: 09/26/12 Date Expires: 09/26/15 APPLICANT: APRIL SURGENT/ZAK HINDERYCKX PHONE: 206-948-6855 4214 S. FINDLAY SEATTLE WA 98118 LEGAL DESCRIPTION: S24 T30 R2W TAX 12 W/1/17TH INT IN COMM AREA W/1/17TH INT IN OG#3 BLK A LOT 16 PARCEL#: 002242018 Section: 24 Township: 30N Range: 02 W DESIGNER: BERNT ERICSEN PHONE: 360-301-0324 293 PINECREST DRIVE PORT TOWNSEND WA 98368 SYSTEM DESCRIPTION: GLENDON BIOFILTER-M31 No. of Gallons per Day: 240 Type of work: NEW Drainfield Trench Septic Tank Length: 40 feet Width: 14 feet Depth: inches Size: 1,000 gallons DISCLAIMER-This approval is for an on-site sewage system that meets the state and county standards in effect on the date of application. This approval for an on-site sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. All construction and development activities must comply with all permit conditions,state and local codes,and Recommended Standards and Guidance documents in effect when the permit is issued. The property owner is responsible for the accurate location of all property lines.Any removal of or major disturbance of soil in the primary or reserve drainfield area may create site conditions that are unacceptable for the installation of a sewage disposal system. Any change in drainfield or tank location may invalidate this permit unless prior approval is obtained from the Jefferson County Environmental Health Division. If during excavation or development of the site an area of potential archeological significance is uncovered, all activity in the immediate area shall be halted, and the UDC Administrator shall be notified at once. Permit issued to CONSTRUCT, ALTER, REPAIR OR MODIFY AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM IN JEFFERSON COUNTY, WASHINGTON This permit is issued for a period of three years (unless otherwise stated above) in accordance with Jefferson County Rules and Regulations for On-Site Sewage Systems, codified in JCC 8.15 as amended. This permit may not be renewed. Jefferson County Enviro mental Health Specialist This permit with conditions must be onsite during , I phases of construction HEALTH DEPARTMENT MUST BE CONTACTED FOR FINAL INSPECTION. SPECIAL CONDITIONS APPLY - SEE ADDITIONAL PAGES CONDITIONS OF APPROVAL - PERMIT NO.: SEP12-00093 1.) A 30' setback shall be maintained from the disposal component and reserve area to roadside drainage ditch. 2.) H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT 3.) Septic tank and pump chamber to be water tight. Extra protection (i.e. Bentonite) to be used around inlet, outlet, and risers due to high water table. 4.) Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling. 5.) Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS. 6.) Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start. 7.) H -An asbuilt drawing and certification of completion by the designer is required prior to final approval. 8.) Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system. 9.) Dry season installation required. 10.) Contact designer prior to installation for staking of drainfield area. 11.) Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required. 12.) All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued. 13.) Divert all sources of drainage, including roof drains away from septic tank and drainfield area. 14.) Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site. 15.) The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 16.) The site plan dated 9-06-2011 submitted for the septic application was reviewed by the The site plan received on 8-7-12 was reviewed by the Department of Community Development on 8-31-12 and it was determined no geotechnical report was required. Any future permits on this site are subject to review for consistency with applicable codes and ordinances. A geotechnical report may be required for any future permits. SEP12-00093 Page 2 of 3 \\tidemark\data\forms\F_SEP_Permitmod.rpt 9/26/2012 17.) The site plan received on 8-7-12 was reviewed by the Department of Community Development on 8-31-12 and it was determined the new septic system meets the requirements in Jefferson County Code 18.22.270(1). The septic location is outside of non fish bearing stream buffer buffer maximum requirement of 75 feet. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and condition which may be placed on future permits. 18.) Marine shorelines and islands are susceptible to a condition that is known as seawater intrusion. Seawater intrusion is a condition in which the saltwater/freshwater interface in an aquifer moves inland so that wells drilled on upland areas cannot obtain freshwater suitable for public consumption without significant additional treatment and cost. Maintaining a stable balance in the saltwater/freshwater interface is primarily a function of the rate of aquifer recharge (primarily through rainfall) and the rate of groundwater withdrawals (primarily through wells). The Washington Department of Ecology is the agency with statutory authority to regulate groundwater withdrawal for individual wells in Jefferson County. New development, redevelopment, and land use activities on islands and in close proximity to marine shorelines in particular should be developed in such a manner to maximize aquifer recharge and maintain the saltwater/freshwater balance to the maximum extent possible by infiltrating stormwater runoff so that it recharges the aquifer. 19.) The parcel is located within a coastal SIPZ (seawater intrusion protection zone) according to the County GIS map. There are voluntary and mandatory measures identified in the Jefferson County Seawater Intrusion Policy (Resolution 44-22, effective September 23, 2002) that apply to well drilling proposals and building permit applications on existing lots of record. A Coastal SIPZ is defined as: all islands and area within one-quarter mile of marine shoreline, but no history of chloride concentration above 100 mg/L in groundwater sources within 1000 feet. 20.) VOLUNTARY MEASURES OF COASTAL &AT RISK SIPZ: Water conservation measures: 1. Roof and other intercepted precipitation shall be routed to on-site detention ponds and/or other approved means and allowed to be released to the soil slowly. 2. Water collected from Storm water and roof catchments may be used for watering lawns and gardens. Unless catchment water has been treated to meet drinking water standards, there shall be no cross connections allowed between the potable supply and impounded water. 3. Water withdrawn from wells on each property shall not be used for watering of lawns and/or gardens. 4. Ground water withdrawn from each property shall be restricted to a rate of three (3) gallons per minute. 5. Installation of water conserving fixtures such as low flow toilets, faucets and shower restrictors and other water saving plumbing fixtures. 6. Landscaping plan (xeriscaping, native vegetation with minimal amounts of irrigation). Please NOTE that the above listed measures are not intended to be exhaustive, but rather is intended to be illustrative of the types of water conservation measures. 21.) MANDATORY MEASURES FOR COASTAL SIPZ: 1. For proof of potable water on a building permit application, applicant must utilize DOH-approved public water system if available. 2. If public water is unavailable, a qualifying alternative system may be used as proof of potable water or an individual well may be used as proof of potable water subject to the following requirement: a. Chloride concentration of a laboratory-certified well water sample submitted with building permit application. 3. If public water is unavailable, a qualifying alternative system may be used as proof of potable water. SEP12-00093 Page 3 of 3 \\tidemark\data\forms\F_SEP_Permitmod.rpt 9/26/2012 a 585655 PGS : 2 COV 08/18/2014 12:13 PM $73.00 APRIL SURGENT Jefferson,,IICounty--WAA Auditor's Office,-!D'o`nna Eldridgge,` Auditor When Recorded Return To: �t11��'i1t� iY�1Yl���ti� � P 1f1•� I�I RritTi����'r�,� Name: Jefferson County Public Health Address: 615 Sheridan City: Port Townsend,WA 98368 Restrictive Covenant Regarding Monitoring of On-site Septic System THIS AGREEMENT is made this date August 14,2014 by and between APRIL SURGENT,his/her heirs and assigns("GRANTOR(S)")and Jefferson County Public Health("GRANTEE") WHEREAS, APRIL SURGENT & ZAK HINDERYCKX is/are the owner/s of a certain tract of land particularly described as follows: PARCEL NO. WHERE SEPTIC SYSTEM IS LOCATED: Parcel#:002242018 LEGAL DESCRIPTION(S): Section: 24 Township 30N Range 2W S24 T30 R2W TAX 12 W/1/17TH INT IN COMM AREA W/1/17TH INT IN OG#3 BLK A LOT 16 ADDRESS OF RESIDENCE SERVED(if assigned): 363 POCKET LN and, WHEREAS,a sewage collection,treatment and disposal system,as described in case#SEP12-00093 has been installed thereon,and WHEREAS,the residence or facility at the above described property,including all parcels associated with said case,utilizes an onsite sewage system which requires regular maintenance and monitoring for the life of the system. Monitoring is required to be performed by a person authorized by the Public Health Department,and WHEREAS,the Owner is required by Jefferson County Public Health Department,as per WAC 246-272A through Jefferson County Code 8.15 to implement a program for periodic monitoring to assure the continuous and satisfactory operation and maintenance of the sewage system,and NOW THEREFORE,in consideration of the premises and the mutual promises and covenants hereafter set forth,the parties hereto agree as follows: 1. Construction:The Owner has constructed and installed a sewage collection,treatment and disposal system together with appurtenant facilities whose capacity and design are satisfactory to the Jefferson County Public Health Department. The plans and specifications for this construction have been approved by the Jefferson County Public Health Department prior to construction. 2. Owners responsibilities: a. Maintain all components as accessible and unobstructed to the surface.Non-accessible or obstructed components will not be serviced and may result in a violation of permit requirements. b. Utilize the system consistent with producing residential waste strength effluent. c. Operate and maintain the system in accordance with conditions of the permit and Jefferson County Code 8.15. Page 1 of 2 3. Attachment If box checked this septic system contains a proprietary device that requires.: Attachment#1 titicIlotice for Maintenance and Monitoring of a Proprietary Onsite Sewage System Device be '�� recorded with this document. 4. Schedule:The Owner shall have their sewage system inspected by a person authorized by Jefferson County Public Health in accordance with the schedule set forth in Jefferson County Code as adopted and hereinafter amended.For some proprietary products registered with the State Department of Health,the inspector must also be' authorized by the device manufacturer. 5. Reminder:The Jefferson County Public Health Department shall provide a reminder of required monitoring. The lack of receipt of said reminder does not relieve the property owner from compliance with the monitoring schedule pursuant to Jefferson County Code. 6. Records:A report of each inspection conducted shall be submitted to the Jefferson County Public Health Department within 30 days of completion of the inspection.Such records shall be open to the inspection of the Owner. 7. Liability:The Grantor agrees to relieve Grantee,its agencies,divisions,officers,agents,and employees of any liability,damages,judgments,claims or other expenses that might arise as a result of the inspections required by this agreement. 8. Fees:A fee as set forth in the Jefferson County Fee schedule and adopted by the Board of County Commissioners shall be paid upon submittal of each inspection report. 9. Terms:This agreement shall remain in full force and effect until the date of notification to the Owner by the Jefferson County Public Health Department that the Owner's Sewer System has been intercepted and connected to a general sewer system. 10. Amendments:This agreement shall not be modified except with the express written approval of the Environmental Health Department of Jefferson County. 11. Penalties: Non-compliance with monitoring and inspection requirements is a violation of Jefferson County Code and shall be subject to enforcement as described in said codes.The County shall have the right to enforce and compel compliance with this covenant,including all remedies available at law and equity. The County shall have the right in any such proceeding to recover its attorney fees and costs. 12. Venues:Venue for any action hereunder shall be in Jefferson County,Washington. If any term or provision of this agreement is in whole or part held invalid or unenforceable by any court of competent jurisdiction,the remainder of this agreement shall continue in full force and effect. 13. Life of Covenants and Binding Effect:All of the promises,covenants,terms and conditions of this agreement shall bind the parties to this agreement and the successors and assigns of the respective parties hereto AND are deemed to run with the land. y � ,Owner 441 ,.l_A .. Owner Acknowledgment: / SUBSCRIBED AND SWORN to beforrme this /~clay of Notary Pub ic Notary ry Si g'ature r ; ` -'' State of Washington CANDICE R. COTTERILL MY COMMISSION EXPIRES Notary public in apd)for the Sate f( �'�„m 1�_, _� �d June 24,2015 residing In /(J) �� '!- i( (( 4`Jlf My commi'sion expires: )i, u f)j `� page 2 of 2 \\tidemark\data\forms\F_SEP_monitoring_agree_20 8/14/2014 JEFFERSON COUNTY PUBLIC HEALTH,615 SHERIDAN, PORT TOWNSEND WA 98368 / ASBUILT INSPECTION REPORT For RECORD DRAWING Designer €R1CSEN DES ICam Permit# SEP la - 93 installer ER I C.SEN EX. (3-015Y K I LyAr't' Parcel# 2 2.4 . 6 Electrician FR ED E1.I GKSON Design Flow 02 4C. 61' Property Owner ; a; 1 : . A. '"' . I . P g Y C k Site Address 363 1fOCkE T LA t4£ Fe/RT TO\i 1'1 SE Pit, WA. g8348 Answer all questions or indicate NA DATE Tanks, Pumps and Controls INSP. Tank (manufacturer, size, baffles) LOTTO N (of)3 GAL. CO1tCRETE is-l?-13 It Pump chamber(manufacturer, size) '1 Screen(s)and/or Pump Shroud (type, location) Qt)TLE T B A F F LE SCREE N IN SE"PTtC. TAN K , O1 c.0 B1oTUBt PV V 57- i&' (9 IN PT. Were Tanks tested onsite for water tightness? E)/No I L-i 7-i 3 Panel Model AQUA \O RX (1P G S C-j - i - 17a1 If Pump 1 — Man./Model i KENC 'PF I O0' Flow Rate l( opm " Pump Location(i.e. garage, treatment unit, basement) 1 )11.1) TANK Float/transducer settings inches Timer from bottom of tank- On/off- .25 in. Functions: On CQ sec/min Veto- 36 in. Off- i sec/min/hr Alarm 3$ in. Veto On- ti sec/min Storage Above High Water Alarm 2020 gal. Veto Off- << sec/min/hr Dose Counter Reading 0 #gallons/dose It gal. Elap. Time Meter Reading 9;31 min/6as Pump Throttled? / No Dose Drawdown (in inches) 14/A in. G A-TE V ALA F' ON 'VIOL/Nibs Pump 2— Man,/Model Flow Rate cpm Pump Location(i.e. garage, treatment unit, basement) Float/transducer settings Inches Timer from bottom of tank- On/off- in_ Functions: On sec/min Veto- in. Off- sec/min/hr Alarm - in. Veto On- sec/min Storage Above High Water Alarm gal_ Veto Off- sec/min/hr Dose Counter Reading #gallons/dose gal. Elap. Time Meter Reading min/ars Pump Throttled? Yes/No Dose QfaVt�EioWn (in inches) in, it additional pumps-complete the info in this table for each and attach. Other Timer functions & settings (e.g. override on/off) Zi 32 - 1a41 VETt5 DOSES 41 ST/MT = . q H:iWEBEONSJTE\AsbuiIt_Report Form.doc 04/28110page I of 2 A L I L (V V L I L U U ►0 0 i l0 ° 0 0 I V U - mO I a)C') a)co V c X + X I < "'' to O SEE W v I m .1 ,LG Q� tIL I M -O 1 ...-d I Lli t l \ci I E NZ " c>6 N ix) '. N ° v F- o ��/ N O c Y `'• u)X f0 Q (n S = a3 , W >- L N v = M c I —I0x 0 aoa y� i o I > 0 u_ v ' ca IdD cn N I O Y > N T� > N f0 I w I _c I o N../ i JQ) I - � R N brii; i - --.) ---- ----**:" v UI t v v I I - m oo _ is co _ io ZZ w F- `° I ZM aO , tVf� � ��p � > .. W 1� CO f�- L!7 ts7 . Li) O I rf1 X J 11 II II II II II 11 II a)) _ N lYN iri UUWIiO2 -� Y O m to Ud I �.. 00000000 w �" 1 m CO m m m m m m cc A- a � m Zo ao ih io ;p i0 o O it .r�°b M (V f. r- b O I- Ln En N fn t 'n r ti ` E . 10 N d v �t 1s t0 ti co W m'=:� c _, 2 II H 11 11 11 11 11 11 c 1- N W r c co°D Vv. v .';` (�i UAW IlC7 = � Y p10 Q' z i» - j:.. 0 a�- - 00000000 i� '/. � \ . IU) � °0 QQQQQQQQ U m 1 I %t� '0. cN Q o c N H I %,%�` 0 W 0 Q 5 m N %1A c U o 0 0 I � 2cnN -) � V I I n I n-. N i oQ w cn1 -n n o 0 r 1 ET) ° m +� '°m 3 n to t 0 N Pal f)"5_ uw (r �. ^z Xi ♦.�:••.�lf��.:.. n M °' —I mZ N:[i ^ED e o j aXS I z co c. -9 I co z N to C * 7 ^ a / CO o a I t N xm I ^ cn t ,0 q ip 0) cn " 0 r ^ 7r 16-0 ro-_,I_______________________, 1 r30`^ = '--)1 CD D o° c v' 1^2 -a --1 i 0 n - 0 n O n %) O � Js m al Q v 0 1 v ^ 1 A t A I us n I 674.83' a O) n N 7°22'42 E 0 \./ I O cn al c p I0 .�. -E- _a• z q # -a ,.., _ 3 � m • 3 °- a I t 0 O 3 F �.., O N oz, ::::31)-s :es- `-) _o tt 0 E. i I �, ' • ty _� U 0. o cam- - ? .. it ti "If' ! a _ o/i'n.,i F yti C8.if it ? to y M -s "4 ..? ‘ ;" is'Y' t 7%' if% I : ) t: ' :ir: Ss v" .e.... __ 1. • A 2 COMPARTMENT SEPTIC TANK DETAIL fA17' PUMP T.t►Nk dET.aLL fNT t'} • f63---.= 63 FILTER SOCK RISERS TO SURFACE t •w:*;+ •+ ..Gf N'ieritexeci 43 CLEAN rR III •AVIA NietuaRt INLET Ili MI I VIM Ma NM MKT 4, �1# o°siuhh1 . •3 NMI MIR NMI • f+'+'�° . / ;/' !�) I PvC CHECK vrALvE CallStr PVC UNION D e () " PVC BALL VALVE 063 as PVC TRANSPORT LINE •'• _ u - d (7,} AOU 4WORX TRANSDUCER t, .r =. �t• - R {•83 SPLICE BOK. _ . y (9) �`c&au J•WLT Lu/f!ot 1MJL.t• o, Dry"" d ra3-v` q YfMLI3 �ilS' at 2 F1f !'I- l 1�9 RIMMED GRACF _1 i=ffl-iii=flf=111=ill—lit=P1 s' rnt,ii- 1= 11^1 i_11i=111=Iii=1f1_ FOR 11 s Get IR 2 causteD starezzaz me comm. _ PER fl oOT/,tee 9-aL.9t3i, i1 % m G°Mutt RASE PER / _ 1t - s-99-01.10 111'. - __--. t1XE2 n RFC I I EQt A- — 11 SL 40 P%C LENT MOM TAPE NARKED 111— 1i FOR AU.ice! AM ISMS HI - ,:.• AREAS USE P PER III --_° ;'rte . ARM T-.L 1---- a aI r/ = 6' , 9 LESS Tim 2 . Iii j WE WEN E P @a RN?AREAS _ onet iuw RAW OR - 1l �' USE - 1i1`1=111=ill=Ill FREE MEW MEWL OR AMC MERU. OF LARGER DWI 1/r; 24"int PVC FFE(I=CONS REOIARRIG 7W Of NOW P iN RAE SUE SWEIRSIL IMRE SNAIL RE l° - P ) PVC PIPE L a%,- NO ,RZ4LE Of -.�4tt y _ 0 o . ii er: f41;iikertic-k)t/51.1.r +: _ x yy i -a.: 1' 5100259 Ott (2() �- �D t S ip?BERNT RAUL ERICSEN • tt - ,ice c S ?DE s. ;.ER.. t • JEFFERSON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 621 SHERIDAN ST.,PORT TOWNSEND .WA 98368, (360) 379-4450 - . _. _ SOIL EVALUATION PROPERTY OWNER 2 CLIC ti Alai i Lk$. / �d r 1 gu.r9 U'1+ SYSTEM DESIGNER ari%se,- 16x1 / LEGAL DESCRIPTION: Section 24 Township 3pij Range.?1,.) Parcel # 00.214.2.0 12 Subdivision Name Division Block Lots) Date Logged: (�-,Li-/.Z Logged BY: I een ErlcScei Include soli textural characteristics and the depths at which ' leant changes occur. Be sure to include depth where mottling or impermeable layers occur. \,\v, SOIL LOG #1 SOIL LOG #2 b to1_in.` r. L.S . R rt 0 to g in. `iir, L.S. 16 to ZD in. L.S. 4.0 W to __//yy 4, 1_to 3tf in. 1144 -t .5. ' `° 30 to 34 in. LS. It f RU 1d to in. L,.5. i 3y- to ite2, in. 4S- Anticipated water table ti.4 in. Anticipated water tabl 31- in. Roots to ti� inches V Roots to 30 inches Health Dept:-Comments ; t Health De . Comments r L, a-ZQ. 4 I y SOIL LOG #3�5 i`' a 4' - i SOIL LOG #4 ' �i 2, Q to it in. L.S.>#, CAI 0°.,, Q to ) in. `ay. (..oa.en 14 to 30 in.$t. L.S. I.a�4 .t8 to 3(, in. 51 dp+a L.s. .36 to 50 in. �, LS. Vii; ;a!e, 34 to 114 in. �}.d L.S. r� 4 to in. �r A 1 to in. . Anticipated water table 30 in. 11 �: ,, , r _ , = x 4f, Anticipated water table in. �� y Roots to Roots to 34 inches 1. inches . 5ttllf25f1 Health De t. Comments 1 ' of C BERNT PAUL ERICSEtV.•.. '$ Health Dept. Comments ,a- 7-, 11 I 1 1 eilY1 1 '=1 1 r I- -!1 SOIL LOG #6 > SOIL LOG #6 0 to It in. We. L A to 3 in. 11. to 30 in.-.St. Ceti L.,S. � ,,,4 4 4 3, � 3 to in. St It'd (. '. _ 3 _to _in. tryll L.S. "- , \ 1 \ ,tit to elf in. klt* L.S. to in. ,�.� A r _.9 'd to S42. in. C LS . Anticipated water table 30 in. !� Anticipated water table „.t� in. Roots to 30 inches _ r\ ',") Roots to 1.1. inches Health Dept. Comments \ � Health Dept. Comments \ ��" H 041 o1L.FRM1100 JEFFERSON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 621 SHERIDAN ST., PORT TOWNSEND .WA 98368, (360)379-4450 - -. _ SOIL EVALUATION PROPERTY OWNER Zak. A ittekLeti c k. /Apei( Suk5 f SYSTEM DESIGNER Er►GSery Tiatir LEGAL DESCRIPTION: Section .34 Township ...30k) Range tl ) Parcel # 60)2.4.„26L Subdivision Name Division Block Lot(s) Date Logged: 6-z4-- ix, Logged By: btrnvi" Ertc Sen include soil textural characteristics and the depths at which significant changes occur. Be sure to include depth where mottling or impermeable layers occur. SOIL LOG # 7 SOIL L O G, iJ 0 to 3 in. '"Dp--tcf r e a to q in. d. i,..5 3 S. , to 32 in. . _. ��ro � i q to .ii in. � :, 32, to �Q i .. -- ,s . ,„: fi .t I to 3 02 i Ma to i it, --. ` °, t 31 to 3$ in. -� C.S. Anticipated water table 33, in. e; : ", - ', .-4 Anticipated water table 3 .in. Roots to .34 inches i e, g3 --- to Roots to a8 inches BEFNIT PAUL SEN + Health Dept. Comments sr • . -�y.• 4 •z---•• 't Health Dept. Comments -,011 vmmotootaislowsymioomm�.K0," l 1 i f_1-1 - is Stilt LOG #3 SOIL LOG #4 to in. to in. to in. to in. to in. to in. to in. to in. . Anticipated water table in. Anticipated water table in. Roots to inches Roots to inches Health Dept. Comments Health Dept. Comments SOIL LOG #5 SOIL LOG #6 to in. to in. to in. to in, to in. to in. to in. to in. Anticipated water table in. Anticipated water table in. Roots to inches Roots to inches Health Dept. Comments Health Dept. Comments H:t1NFOHLTHt501L.FRM Z 100 if 44 a oS L. �.C`�°I°� seN t°Me/ • ' 9P y./� '' :;y. .. X '4, ` Zak Hinde ckx 1 A• ril Sur a ent; . 5100259 + 002242018 set:. BERNT RAUL ERICSEN � ✓ .... s flE I c NER 11 Project Description: Install new two bedroom Glendon Bio — Filter M 31 septic system for proposed shop with bathroom ( no floor drains allowed ) and a two bedroom residence. Septic Tank: Install two compartment mono-pour concrete equipped with water and airtight un vented risers to grade. Tank shall be water tight. Fill tank with water after placement, to be observed by Designer. All openings to be sealed with Bentonite. Septic tank is to be 1000 gallons. Tank to be set on 6" of pea gravel. An outlet baffle filter is required in the septic tank. Screen size to be 1/16".Use Orenco FTJPW 0418. Pump Tank: Pump tank shall be mono-pour concrete equipped with water and airtight un vented riser to grade. Tank shall be water tight. Fill tank with water after placement, to be observed by Designer. All openings to be sealed with Bentonite. Tank to be 1000 gallons. Tank to be set on 6" of pea gravel. Control Panel The Aquaworx Glendon control panel is to be mounted outside, within site of the pump chamber on a post or on a wall of the residence. A transducer is required with this panel. Pump Need pump capable of 10 GPM @ 22.2 TDH. Orenco PF 1005 or equivalent. The turbine pump shall be installed in an Orenco Biotube ( PVU 57 — 1819 ) Glendon Basins The Glendon approved basins to be set on 6" of pea gravel. C — 33 sand to be used where sand is specified and installed at a depth of 1' over entire plowed absorption area. " Bank Run " or " reject " may be used where "cover sand " is specified. Transport Line Approximately 70' of 1" SCH 40 to Splitter located next to Glendon Basins. Install check valve on line to highest basin. Enclose splitter and check valve in riser to grade. Gravity Pipe Gravity pipe to be 4" ASTM 3034 @ 2%. Install C.O.s every 50'. inspections Contractor to contact designer prior to construction to set up pre-construction meeting, and inspection schedule. Contractor to flush laterals prior to contacting designer for pressure test. General Construction Notes 1. The work described herein consists of construction of Glendon BioFilter wastewater system. 2. The contractor shall be knowledgeable and experienced in the construction of this type of wastewater system and shall be a licensed Glendon installer in Jefferson County. 3. if during the installation of the system the contractor finds soil conditions that may lead to premature failure of the system, construction shall be terminated immediately and the designer notified. Such soil conditions may include groundwater, fill, clay, highly compacted soil, bedrock or excessively permeable soils. a. Any inconsistencies, errors, or omissions that, in the opinion of the installer, would compromise the quality of the wastewater system shall be reported to the designer prior to construction. 4. Transport pipe and laterals shall be Schedule 40 PVC, unless otherwise stated in design, solvent welded joints. All fittings shall be Schedule 40. All transport pipe in traffic areas shall be Schedule 40. Backfill in traffic areas shall be pitrun gravel and compacted. All gravity pipe shall conform to ASTM D 3034. All gravity and transport pipe shall be bedded, using native or imported material free of rocks, debris and sharp objects. Double case in traffic areas with 6"ASTM D 3034. 2 . 5. All exposed soil shall be seeded and mulched prior to the final inspection. Seed shall be spread at an approximate rate of 10 lbs. per 5,000 sq. ft. 6. The installer shall be responsible for constructing the system according to plans and conditions of permit and shall be responsible for its proper operation and function for one year. The owner shall be responsible for operating and maintaining the wastewater system in accordance with WAC 240-272A-15501. 7. Any changes, substitutions, or deviation from these plans shall be approved by the designer and by the Jefferson County Environmental Health Department. 8. The installer shall grade to divert all surface water runoff away from tanks and drainfield/reserve areas. 9. The bottom of the trench or bed may be inspected by the designer prior to placing sand fill or drain rock and shall not exceed +1- '/2" from level. 10. Notify designer 48 hrs. prior to pressure test, after permanent power has been connected to panel and L. and 1. inspection complete. Any deletions from plans, or necessary adjustments, shall be completed by installer. 11. Setbacks to all known water lines shall be a minimum of 10'. No crossing of water lines with any septic component shall be allowed, except as included in septic design approved by Jefferson County Health Department. 12. Setback from the building foundation wall shall be 10' minimum to drainfield, 5' minimum to tanks and 2' minimum to non-perforated sewer pipes. 13. Setback from property lines, easements lines, and driveways shall be a minimum of 5', for both drainfield and reserve areas. 14. Water saving appliances, fixtures, and practices are to be used. 15. The septic and pump tanks, drainfield and reserve areas are to be protected from vehicular traffic or mechanical disturbance. 16. The installer is to verify pump requirements at the time of installation. 3 t 17. The designer is to provide the as-built and letter of certification. 18. This system has been designed in accordance with WAC 246-272 A and the most current Department of Health "Recommended Standards and Guidelines for Pressure Distribution Systems," and has been approved by the Jefferson County Health Department. Nevertheless, negligence or improper action on the part of the users could result in the premature failure or malfunction of the system or its components. 4 . . , . 1.1 .. .• .. . ., . w -4 $ ..., . .. . . ' o w — ...3° IllbrON N 7 0 o.. li ( 21411i4 X 4 2 11. ......CI "tt s fx. - (.1 x . 0 d it --4,-.' t, is. 2 ow 1 1 B - ,0 tte" N... s ., -=,2 a 0- ci In zu_re° 1 1 \ I , w'i tc. ale 0,w ' 1 1 4004 ■ , ,r, I 'a), . , , ae, I i ' - .. T Nu w I I ..-.,,, , I I 1-----I', N , . 1 I ---• . _ , =: I I : , ,. ,,, , , '■ , . ,,, , I I r'''-.."'„ . , , .. . . . . „_ I ;i:-' ,,," , •: . ..-- t- y' y I ' .-- ...-- ---3-"-- !-?- ,'/: . . - I r ,- / . . . /-.. - ...., .....- Il ., I - . X Y ■ --...., , , , -.,_ . 1 -----, ,_ , dorms , .... _ , ,.. .... ONSITE SEWAGE DISPOSAL SYSTEM DESIGN 0 0 22 4 l g Date 3-6- /a- Property Owner Z at {LA. lery Gi(A /Argil r '- System Designer EftGSen le,S; n Legal Description: Section 24- Township ,3O Al Range L Subdivision Name Division Block Lot(s) I. CALCULATIONS If for residential use: Number of Bedrooms: at x 120 G.P.D. = a240 total G.P.D. If for non-residential use, attach calculations used to determine G.P.D. Soil texture waste water application rate . , G.P.D./ft. squared (see page 214 of the EPA Design Manual) DRAINFIELD SIZING: Absorption area: 4q3 square feet (total G.P.D. :-G.P.D./ft. squared) Trench or bed width -- feet Mt i4 77 6-13a-sins) ' *8.3 Trench or bed length 4b lineal feet (sq. ft. trench or bed width) II. APPURTENANCES Septic Tank Size idib gallons Pump Requirements (if Necessary) Elevation difference in feet is Friction loss 1.J. Pump capacity should be 14 G.P.M. at ,k2.1 T.D.H. Number of doses per day 41.e,ihr S' '.5 Dosing volume gallons •� Pump chamber size /o,t gallons ' ! 4... 1#4r. :.* 5100259 �'�,�'BERNT Fes.ERICSEN •. i� r uCENtd i NER 1 H:`.home\pincntr\infofdthIsewdsn i3-7-l'. Pump Selection for a Non-Pressurized System -Single Family Residence Project Hinderyckx/Surgent 00.2A14-4.4 tg Parameters Discharge Assembly Size 1.00 inches 400 PF1010 Transport Length 70 feet illiM11111111111111111111111111111111111- Transport Pipe Class 40 -- E -� - Transport Line Size 1.00 inches J Distributing Ua bte Model None 350 Max Elevation Lift 15 feet I MEI MEI Design Flow Ram 10 gpm I -`�-�- Flow eld-on' ri None inches I _�_`� Add-on'Friction Losses 0 feet Rillalum 300 i Calculations Transport Velocity 3.7 fps -- ----- Factional Head Losses S 250 iii1 ft-��—H—i:�l•i��-- iili♦ IIIEM— •11111 Lossthrough Discharge 3.3 feet --1.11-1101-a�'�- Loss in Transport 3.9 feet I- 4 • MMI--=111111111B Loss through Valve 0.0 feet m 'IIII -IIIIII-■111111111 �, M1 Loss through Flowmeter 0.0 feet S 200-'�'-iM_�-�l•7lt 'Add-one Friction Losses 0.0 feet -- 1111111111111111111110111111111 11111111111111.111111111111111 Pipe Volumes --- ����MIIIIIIIIMIIIIIIIIIIIIIIIIIIIIIIIIIIIIIMIIIIIIIIIIRIIIIIMIL IN Vol of Transport Line 3.1 gals c 150 II%MIIIIIMIIIIIIIIIIIII Minimum Pump Requirements I- MEN -1-►I� Design Flow Rate 10.0 gpm Total Dynamic Head 22.2 feet 100 --Ill i 44 I I I so 1 o lio, it E ? II �' ...F 46 - Z...;.`ti' ...... ..s_■—___ I_♦I_• 5100259 • .4 0 5 10 15 �F 13 ERNT PAUL ERICSEN.'•. i Net Discharge m) . i. r °21111-43-9-7-1.).- 9-?-ice PumpEhrta Legend PF1005 High Head Effluent Pump System Curve: 10 GPM,1/2HP 115/23)V 10 60Hz,20W 3060Hz Pump Curve: PF1007 High Head Effluent Pump Pump Optimal Ranger 10 GPM,3/4HP 230V 10 60Hz,200V 30 60Hz Operating Point() PF1010 High Head Effluent Pump Design Point() 10 GPM,1HP 230V 1060Hz,200V 3060Hz r C Orenco systems° Incorporated C gng the Way d Itadd flora wennuar,-.