HomeMy WebLinkAboutBLD2014-00161 SILDING PERMIT APPLICATISI BLD14-00161
Review Type:
Jefferson County Department of Community Development
621 Sheridan Street Port Townsend, WA 98368
PERMIT#: BLD14-00161 Received Date: 5/6/2014
SITE ADDRESS: 50 JONATHAN PL
PORT HADLOCK, 98339
OWNER: LAURA L CLOUSE PHONE: 360-301-6068
50 JONATHAN PL
PORT HADLOCK WA 98339-9405
CHIMACUM CREEK EST
SUBDIVISION: Block: Lot:
PARCEL NUMBER: 943600024 Section: 2 Township: 29 N Range: 01 W
CONTRACTOR: NORDIC SERVICES INC PHONE: 360-792-2565
PO BOX 1492
BREMERTON WA 98337
Contractor's License NORDISI180QA Expires 1/1/2016
REPRESENTATIVE: PHONE:
PROJECT DESCRIPTION FIRE DAMAGE IN KITCHEN& LIVING ROOM REPAIR
TYPE OF WORK RES SQUARE FOOTAGE:
TYPE OF IMP REP MAIN:
VALUATION 5,800.00 ADD'L: HEAT TYPE:
CODE EDITION: 2012 HEAT BASE: HEAT TYPE:
OCCUPANCY: UNHEATED: #OF STORIES:
OCCUPANCY: OTHER:
CONST TYPE: GARAGE: SHORELINE:
CONST TYPE: DECK: SETBACK:
BANK HEIGHT:
SEWAGE DISPOSAL:
WATER SYSTEM:
BEDROOMS: BATHROOMS:
Exist: Exist:
Prop: Prop:
Total: Total:
Routing Date:
Type Amount Paid By: Date: Receipt: Approved/Date
Permit $113.00 JLA 05/06/14 148598 APPROVED
Plan Check $73.45 JLA 05/06/14 148598
State Building Code $4.50 JLA 05/06/14 148598 MAY 0 6 2014
Total: $190.95 Jefferson County DCD
\\firlomorWrlofolfnrme\F RI rl Ann 1:1 rnf AIRI901A
• 0
" ` (i DEPARTMENT OF COMMUNITY DEVELOPMENT
-; 621 Sheridan Street,Port Townsend,WA 98368
Tel:360.379.4450 I Fax:360.379.4451
Web:www.co.jefferson.wa.us/communitydevelopment
74 Ff2 NO ) E-mail:dcdaco.jefferson.wa.us
CERTIFICATE OF OCCUPANCY
1
1
1
PERMIT#: BLD14-00161
APPLICANT: LAURA L CLOUSE PHONE: 360-301-6068
50 JONATHAN PL
PORT HADLOCK WA 98339-9405
SITE ADDRESS: 50 JONATHAN PL Issue Date: 05/6/2014
PORT HADLOCK, 98339 Final Date: 9/4/2014
SUBDIVISION: 9436 Block: Lot:
PARCEL NUMBER: 943600024 Section: 2 Township: 29 N Range: 1w
PROJECT DESCRIPTION: FIRE DAMAGE IN KITCHEN & LIVING ROOM REPAIR
THE PROJECT LISTED ABOVE COMPLIES WITH THE REQUIREMENT OF THE BUILDING CODE 2012
EDITION.
OCCUPANCY GROUP:
TYPE OF CONSTRUCTION:
SPRINKLER SYSTEM yes no
THE PROJECT PASSED ITS FINAL INSPECTION AND RECEIVED FINAL SIGN OFF ON 9/4/2014
II
\\tidemark\data\forms\F_BLD_Occupancy.rpt 9/19/2014
• IIIVASHINGTON STATE AMENDMENTS
R315.3 Where required in existing dwellings.Existing
dwellings shall be equipped with carbon monoxide alarms
in accordance with Section 8315.1. An inspection will
occur when alterations,repairs or additions requiring a
permit occur,or when one or more sleeping rooms are
added or created.
Exceptions:
1. Work involving only the exterior surfaces of
dwellings,such as the replacement of roofing or
siding,or the addition or replacement of windows
or doors,or the addition of a porch or deck,or
electrical permits,are exempt from the inspection
requirements of this section.
2. Installation, alteration or repairs of nonfuel
burning•.plumbing or mechanical systems are
exempt from the inspection requirements of this
section..
3. Owner-occupied single-family residences legally
occupied before July 26,2009: RCW 19.27.530
(2Xb).
R315.4 Alarm requirements.Single station carbon
monoxide alarms shall be listed as complying with UL
2034 and shall be installed in accordance with this code,
I ■FPA 720-2012 and the manufacturer's installation
instructions.
(Insert Facing Page 64)
Effective July 1,2013
BUILDING PLANNING • •
I
pancy, owned by the homeowner and shall be monitored by R316.5.1 Masonry or concrete construction. The ther-
an approved supervising station. mal barrier specified in Section R316.4 is not required in a
Exception: Where carbon monoxide alarms are installed masonry or concrete wall, floor or roof when the foam
meeting the requirements of Section R315.1, compliance
plastic insulation is separated from the interior of the
with Section 315.2 is not required. building by a minimum 1-inch (25 mm) thickness of
masonry or concrete.
R315.3 Where required in existing dwellings.Where work R316.5.2 Roofing. The thermal barrier specified in Sec-
requiring a permit occurs in existing dwellings that have
attached garages or in existing dwellings within which fuel- tion R316.4 is not required when the foam plastic in a roof
assembly or under a roof covering is installed in accor-
fired appliances exist, carbon monoxide alarms shall be pro-
vided in accordance with Section R315.1. dance with the code and the manufacturer's installation
instructions and is separated from the interior of the build-
R315.4 Alarm requirements. Single-station carbon monox- ing by tongue-and-groove wood planks or wood structural
ide alarms shall be listed as complying with UL 2034 and panel sheathing in accordance with Section R803,not less
shall be installed in accordance with this code and the manu- than 15/32 inch (11.9 mm) thick bonded with exterior glue
facturer's installation instructions. and identified as Exposure 1, with edges supported by
blocking or tongue-and-groove joints or an equivalent
material.The smoke-developed index for roof applications
SECTION R316 shall not be limited.
FOAM PLASTIC R316.5.3 Attics. The thermal barrier specified in Section
R316.1 General. The provisions of this section shall govern R316.4 is not required where all of the following apply:
the materials, design, application, construction and installa- 1. Attic access is required by Section R807.1.
tion of foam plastic materials. 2. The space is entered only for purposes of repairs or
R316.2 Labeling and identification. Packages and contain- maintenance.
ers of foam plastic insulation and foam plastic insulation 3. The foam plastic insulation is protected against igni-
components delivered to the job site shall bear the label of an tion using one of the following ignition barrier mate-
approved agency showing the manufacturer's name, the rials:
product listing, product identification and information suffi-
cient to determine that the end use will comply with the 3.1. 1'/2-inch-thick(38 mm)mineral fiber insula-
requirements. tion;
R316.3 Surface burning characteristics. Unless otherwise 3.2. 1/4-inch-thick (6.4 mm) wood structural pan-
allowed in Section R316.5 or R316.6, all foam plastic or els;
foam plastic cores used as a component in manufactured s
assemblies used in building construction shall have a flame 3.3. /8 inch(9.5 mm)particleboard;
spread index of not more than 75 and shall have a smoke- 3.4. 1/4-inch(6.4 mm)hardboard;
developed index of not more than 450 when tested in the
maximum thickness intended for use in accordance with 3.5. ;/$ inch(9.5 mm)gypsum board;or
ASTM E 84 or UL 723. Loose-fill-type foam plastic insula- 3.6. Corrosion-resistant steel having a base metal
Lion shall be tested as board stock for the flame spread index thickness of 0.016 inch(0.406 mm);
and smoke-developed index.
3.7. 11/,-inch-thick(38 mm)cellulose insulation. '
Exception: Foam plastic insulation more than 4 inches
(102 mm)thick shall have a maximum flame spread index The above ignition barrier is not required where the
foam plastic insulation has been tested in accordance with
of 75 and a smoke-developed index of 450 where tested at
a minimum thickness of 4 inches (102 mm),provided the Section R316.6.
end use is approved in accordance with Section R316.6 R316.5.4 Crawl spaces. The thermal barrier specified in
using the thickness and density intended for use. Section R316.4 is not required where all of the following
I
R316.4 Thermal barrier. Unless otherwise allowed in Sec- apply:
tion R316.5 or Section R316.6, foam plastic shall be sepa-
rated from the interior of a building by an approved thermal 2. Entry is made only for purposes of repairs or main
barrier of minimum 1/2 inch (12.7 mm) gypsum wallboard or tenance.
a material that is tested in accordance with and meets the
acceptance criteria of both the Temperature Transmission 3. The foam plastic insulation is protected against igni-
tion Test and the Integrity Fire Test of NFPA 275. tion using one of the following ignition barrier mate-
rials:
R316.5 Specific requirements. The following requirements 3.1. 1'/,-inch-thick(38 mm)mineral fiber insula-
shall apply to these uses of foam plastic unless specifically
approved in accordance with Section R316.6 or by other sec- tion;
tions of the code or the requirements of Sections R316.2 3.2. 1/4-inch-thick(6.4 mm)wood structural pan-
through R316.4 have been met. els;
64 2012 INTERNATIONAL RESIDENTIAL CODE®
• • BUILDING PLANNING
ing buildings that are not already provided with an auto- doors, or the addition of a porch or deck, are
matic residential sprinkler system. exempt from the requirements of this section.
R313.2.1 Design and installation. Automatic residential 2. Installation, alteration or repairs of plumbing or
fire sprinkler systems shall be designed and installed in mechanical systems are exempt from the require-
accordance with Section P2904 or NFPA 13D. ments of this section.
R314.4 Power source.Smoke alarms shall receive their pri-
SECTION R314 mary power from the building wiring when such wiring is
SMOKE ALARMS served from a commercial source,and when primary power is
interrupted, shall receive power from a battery. Wiring shall
IR314.1 Smoke detection and notification. All smoke be permanent and without a disconnecting switch other than
alarms shall be listed and labeled in accordance with UL 217 those required for overcurrent protection.
and installed in accordance with the provisions of this code Exceptions:
and the household fire warning equipment provisions of
NFPA 72. 1. Smoke alarms shall be permitted to be battery oper-
R314.2 Smoke detection systems.Household fire alarm sys-
tems installed in accordance with NFPA 72 that include power.
smoke alarms, or a combination of smoke detector and audi- 2. Hard wiring of smoke alarms in existing areas shall
ble notification device installed as required by this section for not be required where the alterations or repairs do
smoke alarms, shall be permitted. The household fire alarm not result in the removal of interior wall or ceiling
system shall provide the same level of smoke detection and finishes exposing the structure, unless there is an
alarm as required by this section for smoke alarms. Where a attic,crawl space or basement available which could
household fire warning system is installed using a combina- provide access for hard wiring without the removal
tion of smoke detector and audible notification device(s), it of interior finishes.
shall become a permanent fixture of the occupancy and R314.5 Interconnection.Where more than one smoke alarm
owned by the homeowner.The system shall be monitored by is required to be installed within an individual dwelling unit
an approved supervising station and be maintained in accor- in accordance with Section R314.3,the alarm devices shall be
dance with NFPA 72. interconnected in such a manner that the actuation of one
Exception:Where smoke alarms are provided meeting the alarm will activate all of the alarms in the individual unit.
requirements of Section R314.4. Physical interconnection of smoke alarms shall not be
R314.3 Location.Smoke alarms shall be installed in the fol required where listed wireless alarms are installed and all
lowing locations: alarms sound upon activation of one alarm.
1. In each sleeping room. Exception: Interconnection of smoke alarms in existing
areas shall not be required where alterations or repairs do
2. Outside each separate sleeping area in the immediate not result in removal of interior wall or ceiling finishes
vicinity of the bedrooms. exposing the structure,unless there is an attic,crawl space
3. On each additional stop' of the dwelling, including or basement available which could provide access for
basements and habitable attics but not including crawl interconnection without the removal of interior finishes.
spaces and uninhabitable attics. In dwellings or dwell-
ing units with split levels and without an intervening SECTION R315
door between the adjacent levels, a smoke alarm CARBON MONOXIDE ALARMS
installed on the upper level shall suffice for the adjacent
lower level provided that the lower level is less than R315.1 Carbon monoxide alarms.For new construction,an
one full story below the upper level. approved carbon monoxide alarm shall be installed outside of
~ each separate sleeping area in the immediate vicinity R314.3.1 Alterations, repairs and additions. When p P� g y of the
alterations, repairs or additions requiring a permit occur, bedrooms in dwelling units within which fuel-fired appli-
ances are installed and in dwelling units that have attached
or when one or more sleeping rooms are added or created
in existing dwellings,the individual dwelling unit shall be garages.
equipped with smoke alarms located as required for new R315.2 Carbon monoxide detection systems.Carbon mon-
dwellings. oxide detection systems that include carbon monoxide detec-
Exceptions: tors and audible notification appliances, installed and
maintained in accordance with this section for carbon monox-
1. Work involving the exterior surfaces of dwell- ide alarms and NFPA 720, shall be permitted. The carbon
ings,such as the replacement of roofing or siding, monoxide detectors shall be listed as complying with UL
or the addition or replacement of windows or 2075. Where a household carbon monoxide detection system
is installed, it shall become a permanent fixture of the occu-
2012 INTERNATIONAL RESIDENTIAL CODE® 63
25' l"
24' 5"
Garage
S
Dining Roo i ( 1 )
I iving Room
8' 11"
Kitchen -
L 9' 11"
,
tn
1 I 9' 3"
1 ;
:11 Entry/Hallway 7
F.)
11' 3"
„ E • " 1 t
.
Bedroom 1 ,
BatassM -
wa 1 ) _
11 4' ---3' 11" 6" -1 =
C•1
B 16' 3" -St`n 3' 6" —1 Ha 1 Mstr C ster BIt
6'
4.
1 ..4 J ?t
no
6' 5" --I
>ft,
h= Master Bedroom
,77_,4 Bedroom 2 -
kw¢soN c'oo JEFF ON COUNTY ( L°
c.:`; -3...4 DEPARTMENT OF COMMUNITY DEVELOPMENT
.,.). 10.. . 621 Sheridan Street I Port Townsend,WA 98368 Web:www.co.Jefferson.wa.us/communitydevelopment
Tel:360.379.4450 I Fax:360.379.4451 I Email:dcd @co.lefferson.wa.us
Building Permits&Inspections I Development Consistency Review I Long Range Planning I Watershed Stewardship Resource Center
Master Permit Application MLA:
Project Description(include separate sheets as necessary): r J 'b :�,,;� $"
1 !.IQrC 1�A. ,ii,e, t, `4' Alt L�c.tv� ( L-., '�.r`v, �o rj.,-ei1 �Y!�Cei r / J fse "
Tax Parcel Number: (712-1q:-) ((1,()00 4 Property Size: (acres/square feet)
Site Address and/or Directions to Property:
S ■ (I.Ni ATrlkki PLA-eE , Pav—i ,i_4c,(_- +Ai q7 )3ci
Property Owner(s)of Record: 1--u\/Vcti (J10 v a-Q.
Telephone:(3 t>z(30(- (u,n(p Fax:_ email:
Mailing Address: ,\,,,\RSV\R v\ Q1(�C. , ** C`x9.(03,, QV* c\ 2, c1
Applicant/Agent(if different from owner): K\D2_ \C 5ce f\C F S * I��C.
Telephone: ?)\9D T a-a cis c- Fax 310 0---)ci i C)49 email: li• • u _ to ivv. 3
Mailing Address: PO ecx )416N, e-)r a I r-I-on \M1\ clg3?J"-4- nt`;Yri(cS-CtrVrc-e-S.CaM
What kind of Permit?(Check each box that applies ❑Lot or Road Segregation
[Building ❑Critical Areas Stewardship Plan
❑ Demolition Permit ❑Variance(Minor, Major or Reasonable Economic Use)
XiSingle Family ❑Garage Attached/Detached ❑Conditional Use[C(a),C(d),or C]**
❑ Manufactured Home ❑ Modular ❑ Discretionary"D"or Unnamed Use Classification
❑ Commercial* ❑Special Use(Essential Publi acilities)**
❑ Change of Use ❑Boundary Line Adjustment i 4
❑ Address ❑Road Approach ❑Short Plat** '4
❑Home Business ❑Cottage Industry ❑Binding Site Plan** 't el-(/( 4." i
❑Propane ❑Long Plat** 111,,n .
❑Sign ❑Planned Rural Residential De -lopment(PRRDyAmendment w
❑Allowed"Yes"Use Consistency Analysis ❑Plat Vacation/Alteration** I
❑Stormwater Management ❑Shoreline Master Program Exemption/Permit Revisions** c--
❑Site Plan Approval Advance Determination(SPAAD)* ❑Shoreline Management Substantial Development**
❑Temporary Use ❑Shoreline Management Variance
❑Wireless Telecommunication* ❑Comprehensive Plan/UDC/Land Use District Map Amendment
❑Forest Practices Act/Release of Six-Year Moratorium ❑Jefferson County Shoreline Master Program Amendment
*May require a Pre—Application Conference ❑Tree Vegetation Request
**Requires a Pre-Application Conference
Please identify any other local,state or federal permits required for this proposal, if known:
�7 DES NATION OF AGENT
I hereby designate (1Z :• 1 ' d to •
act as my agent in •matters relating •to this application •for permit(s).
OWNER SIGNATURE , / , ;,r, ��� Date: 'Y • 0
By signing this applicatio form,the owner/age, attests that the information provided herein,and in any attachments,is tr -and correct to the best of
his,her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet
may result in this permit being null and void.
I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and
expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit.
I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application
review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the
time of the app n th he or she nts prior noti
Signature: Date: y°22 /II
The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or
endangered species and could lead to a potential"take"of an endangered species as those terms are defined in the federal law known as the
"Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this
permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your
action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual
and non-tra respo ibility for dherin and.complying with the ESA. The Applicant has read this di aimer and signs and dates it below.
^ � Date: ' -' 2L^ /L/
Signature: � ldttA
07/24/2013
ill
BUILDER STATEMENT •
The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that
they will be assuming the responsibility of the General Contractor for the proposed project.
Signature: Date:
GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX:
1V \Q S \1t Cis, >�C, - (506) 1 q g:-,,,/ --(s, (31°D )1 1 a-U 1 Li 9
MAILING ADDRESS: -pD f . ( J LCla
6 r-elliti Him vol cic'33- EMAIL: )'Y21v\1/-V -0 at r (1(" ftO'r{IC.S"p rvlas (ora
CONTRACTOR'S LICENSE WAINS 1
NUMBER: V r, (0(2---0 c J z '70�f NUMBER
ARCHITECT/ENGINEER: PHONE ( ) FAX:( )
MAILING ADDRESS: EMAIL
Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal:
❑ New ❑ Wood Existing: ❑ Sewer
❑ Addition ❑ Steel Proposed: Bank ❑ Community System
❑ Alteration/Remodel ❑ Concrete Total: Height: ❑ Individual System
❑ Repair ❑ Masonry SEP Permit#
❑ Demolition ❑ Other: Bedrooms: Water Supply:
Existing: Setback: ❑ Private well ❑ Two Party
Type of Heat: Proposed: ❑ Public
Total: Name of System:
If this is a Commercial Proiect you must answer the following:
Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces:
Number of occupants(includes owners,tenants,employees,etc) Current Proposed
IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No
If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply:
Underground Tank Above ground tank Size of Propane Tank:
Heat Stove Cook Stove Woodstove Fireplace.nsert rehtO i evotS telleP I knaT retaWtoH i
Is this appliance being installed in a Manufactured I Mobile Home? Yes / No
When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property
lines,tank location and size,distances from the propane tank to all property lines,buildings and septic system components,
including the reserve area.
Square Footage Current Proposed For O ce Use Only Amount Revi
Main Floor Heated EH Bld App Review.
2"tl Floor Heated Consistency Review.
Other Heated Base fee: c,,,>
Mezzanine - Additional Section:
l
Heated Basement Plan Check fee: �/—
J
Unheated Basement State Surcharge fee: ct`
Other Unheated Pot Water Review fee:
Garage/Carport SUBTOTAL
Decks 911/Rd Approach fee:
Other
TOTAL: $ Ibel ,4c. .
Receipt Number: /4S7,f5 '�
Cash/Check Number: �, I v 1 e 05
ESTIMATED COST(REQUIRED) Date: Z L /� 5) t�'
.Fair m rk value of all labor and materials foundation to finish J r
,(41 Initials:
.
8" ....
07/24/2013
i
i •
Insured: LAURA CLOUSE Cell: (360)301-6068
Property: 50 JONATHAN PLACE E-mail: MHUBBARD @ALLSTATE.COM
PORT HADLOCK, WA 98339-9405
Home: 50 JONATHAN PL
PORT HADLOCK,WA 98339-9405
Claim Rep.: Brisco Gugich Business: (425)466-4726
Position: Field Adjuster E-mail: bgugi @allstate.com
Company: Allstate
Business: 18911 North Creek Parkway
Bothell,WA 98001
Estimator: Brisco Gugich Business: (425)466-4726
Position: Field Adjuster E-mail: bgugi @allstate.com
Company: Allstate
Business: 18911 North Creek Parkway
Bothell,WA 98001
Contractor:
Company: None
Claim Number: 0307944990 Policy Number: 000087054482 Type of Loss: Fire
Date Contacted: 12/4/2013
Date of Loss: 12/2/2013 8:30 AM Date Received: 12/2/2013 1:25 PM
Date Inspected: 12/10/2013 Date Entered: 12/27/2013 1:22 PM
Date Est. Completed: 1/24/2014 3:00 PM
Price List: WAOL8X DEC13
Restoration/Service/Remodel
Estimate: LAURA_CLOUSE1
Allstate is dedicated to providing you with outstanding service throughout the claim-handling process. If you have any questions
regarding this estimate,or if there are differences with the estimate provided by your repairperson of choice,or if additional
damage is found during the repair process,please contact us at(425)466-4726.
Thank you,
Brisco Gugich
to CC91
0.‘
• S
LAURA_CLOUSE1
SKETCH!
Main Level
Main Level
DESCRIPTION QTY UNIT PRICE TOTAL
98. Electrical(Bid Item) 1.00 EA @ 0.00
Open item for electrical costs
Living Room Height:7'7"
Door 8'X 6' 10" Opens into Exterior
Missing Wall 3'5"X 7' 7" Opens into HALLWAY
Missing Wall 1' 10" X 7'7" Opens into ENTRY_HALLWA
Door 3'X 6' 10" Opens into GARAGE
Subroom: Dining Room(1) Height: 7'7"
Missing Wall 9'X 7' 7" Opens into LIVING_ROOM
Missing Wall 8' 11" X 7'7" Opens into KITCHEN
Window 4' 11" X 3' 5" Opens into Exterior
DESCRIPTION QTY UNIT PRICE TOTAL
9a. Remove Blown-in insulation- 12"depth-R30 337.00 SF @ 0.75= 252.75
9b. Blown-in insulation- 12" depth-R30 337.00 SF @ 0.85= 286.45
21a. Remove Vinyl tile 81.75 SF @ 0.86= 70.31
Vinyl tile laid over parquet flooring.
11. Remove Parquet flooring 81.75 SF @ 2.65 = 216.64
14a. Remove 1/2"drywall-hung,taped,ready for texture 337.00 SF @ 0.32= 107.84
14b. 1/2" drywall-hung,taped,ready for texture 337.00 SF @ 1.41 = 475.17
Removing other side of burnt kitchen wall
16. Acoustic ceiling(popcorn)texture 337.00 SF @ 0.75= 252.75
Popcorn ceilings need to come down to properly remove insulation and smoke seal the rest of the attic space above the other rooms in
the home. Ceilings are already half falling down due to water damage and fire department.
17a. Remove 1/2"drywall-hung,taped,ready for texture 123.69 SF @ 0.32= 39.58
17b. 1/2"drywall-hung,taped,ready for texture 123.69 SF @ 1.41 = 174.40
Drywall needing to be removed to properly repair burnt stud and wet/removed drywall. Adjust after mitigation. Includes 1'down
ceilings to properly tie into new ceilings.
18. Texture drywall-light hand texture 184.19 SF @ 0.41 = 75.52
23a. Remove Baseboard-2 1/4" 57.83 LF @ 0.32= 18.51
Only one small piece of trim still remaining.
25a. Remove Ceiling fan&light 1.00 EA @ 14.33 = 14.33
Corroded and water damaged.
LAURA_CLOUSE1 4/21/2014 Page: 2
. •
Kitchen Height:7'7"
Missing Wall 8' 11" X 7'7" Opens into DINING_ROOM
Window 3'X 3'5" Opens into Exterior
Missing Wall 2' 10" X 7'7" Opens into ENTRY_HALLWA
DESCRIPTION QTY UNIT PRICE TOTAL
27a. Remove Stud wall-2x4(per BF) 7.58 BF @ 0.16= 1.21
27b. Stud wall-2x4(per BF) 7.58 BF @ 1.68= 12.73
Replacing one burnt stud.
29a. Remove Blown-in insulation- 12"depth-R30 71.33 SF @ 0.75= 53.50
29b. Blown-in insulation- 12"depth-R30 71.33 SF @ 0.85 = 60.63
30a. Remove Vinyl tile 71.33 SF @ 0.86= 61.34
Vinyl tile laid over parquet flooring. t
31. Remove Parquet flooring 71.33 SF @ 2.65 = 189.02
33a. Remove 1/2"drywall -hung,taped,ready for texture 71.33 SF @ 0.32= 22.83
33b. 1/2"drywall-hung,taped,ready for texture 71.33 SF @ 1.41 = 100.58
kitchen wall drywall behind range
34. Acoustic ceiling(popcorn)texture 71.33 SF @ 0.75= 53.50
Popcorn ceilings need to come down to properly smoke seal the rest of the attic space above the other rooms in the home.
35a. Remove 1/2"drywall -hung,taped,ready for texture 85.40 SF @ 0.32= 27.33
35b. 1/2"drywall-hung,taped,ready for texture 85.40 SF @ 1.41 = 120.41
Removing drywall on partial wall to properly repair stud wall and electrical.Removing drywall I'down the walls to properly tie in
new ceilings.
99. Drywall Installer/Finisher-per hour 1.50 HR @ 62.90= 94.35
Additional labor to tie in drywall to new ceiling.
36. Texture drywall -light hand texture 111.40 SF @ 0.41 = 45.67
Replacing entire stretch of drywall behind range and kitchen cabinets from smoke and fire damages.
39a. Remove Light fixture 2.00 EA @ 6.33= 12.66
40a. Remove Cabinetry-upper(wall)units-High grade 12.00 LF @ 5.70= 68.40
Basic plywood box, stained cabinets
42a. Remove Cabinetry- lower(base)units-High grade 8.00 LF @ 5.70= 45.60
Basic plywood box,stained cabinets
44a. Remove Backsplash-plastic laminate 16.00 SF @ 0.68= 10.88
CHECK MEASUREMENT DURING WALKTHROUGH
45. Sink-double-Detach&reset 1.00 EA @ 118.43= 118.43
48a. Remove Dishwasher 1.00 EA @ 20.34= 20.34
Been sitting and frozen for quite some time during the freeze.Backing will also be saturated with smoke and smoke odor.
49. Dishwasher connection 1.00 EA @ 110.76= 110.76
50a. Remove Window blind-wood-2" -7.1 to 14 SF 1.00 EA @ 7.65= 7.65
53a. Remove Refrigerator-top freezer- 14 to 18 cf 1.00 EA @ 25.32= 25.32
112a. Remove Ductwork-hot or cold air- 10" round 7.00 LF @ 1.15= 8.05
112b. Ductwork-hot or cold air- 10"round 7.00 LF @ 15.98= 111.86
Remove and replace 7'run of HVAC for range hood.
113. Electrician-per hour 3.00 HR @ 91.12= 273.36
Detatch and reset/rough in electrical box under kitchen sink into new cabinets.
LAURA_CLOUSEI 4/21/2014 Page: 3
1
a•
Entry/Hallway Height:7'7"
Door 2' 1"X 6' 8" Opens into ENTRY_CLST
Door 3'2"X 6' 8" Opens into Exterior
Missing Wall 2' 10" X 7'7" Opens into KITCHEN
Missing Wall 1' 10" X 7'7" Opens into LIVING_ROOM
Subroom: Hallway(1) Height:7'7"
Door 2'9"X 6' 11" Opens into BEDROOM_1
Missing Wall 3'5" X 7' 7" Opens into LIVING_ROOM
Missing Wall 3' 11" X 7'7" Opens into ENTRY_HALLWA
Door 2'8" X 6' 11" Opens into BATHROOM
Door 4' 10" X 6'8" Opens into HALL_CLST
Door 2'9"X 6' 11" Opens into MASTER_BEDRO
Door 2'9" X 6' 11" Opens into BEDROOM_2
DESCRIPTION QTY UNIT PRICE TOTAL
68a. Remove Blown-in insulation- 12" depth-R30 101.25 SF @ 0.75= 75.94
68b. Blown-in insulation- 12" depth-R30 101.25 SF @ 0.85= 86.06
72a. Remove 1/2" drywall-hung,taped,ready for texture 158.50 SF @ 0.32= 50.72
72b. 1/2"drywall-hung,taped,ready for texture 158.50 SF @ 1.41 = 223.49
Replacing ceiling plus 1'down walls to properly tie into new ceiling.
73. Acoustic ceiling(popcorn)texture 101.25 SF @ 0.75= 75.94
Popcorn ceilings need to come down to properly smoke seal the rest of the attic space above the other rooms in the home.
101. Texture drywall-light hand texture 114.50 SF @ 0.41 = 46.95
78a. Remove Light fixture 1.00 EA @ 6.33= 6.33
Replace light fixtures due to humidity and smoke.
115a. Remove Baseboard-2 1/4" 36.25 LF @ 0.32= 11.60
116a. Remove Casing-2 1/4" 10.33 LF @ 0.38= 3.93
Around attic access
119. Remove Carpet 101.25 SF @ 0.23= 23.29
Carpet ran previously only down the hallway to where it meets the living room.
Bedroom 1 Height:7'7"
Door 5'9" X 6' 8" Opens into B1_CLST
Door 2'9" X 6' 11" Opens into HALLWAY
Window 4' 11" X 3' 5" Opens into Exterior
DESCRIPTION QTY UNIT PRICE TOTAL
85. Remove Carpet 111.81 SF @ 0.23= 25.72
88a. Remove Blown-in insulation- 12" depth-R30 111.81 SF @ 0.75= 83.86
88b. Blown-in insulation- 12" depth-R30 111.81 SF @ 0.85= 95.04
137a. Remove Carpet pad 111.81 SF @ 0.09= 10.06
LAURA_CLOUSE1 4/21/2014 Page: 4
• •
B1 Clst Height: 7'7"
Door 5'9"X 6' 8" Opens into BEDROOM_1
DESCRIPTION QTY UNIT PRICE TOTAL
89a. Remove Blown-in insulation- 12" depth-R30 13.69 SF @ 0.75= 10.27
89b. Blown-in insulation- 12" depth-R30 13.69 SF @ 0.85 = 11.64
126. Remove Carpet 13.69 SF @ 0.23= 3.15
136a. Remove Carpet pad 13.69 SF @ 0.09= 1.23
B2C1st Height:7'7"
Door 5'9" X 6' 8" Opens into BEDROOM_2
DESCRIPTION QTY UNIT PRICE TOTAL
90a. Remove Blown-in insulation- 12"depth-R30 11.66 SF @ 0.75= 8.75
90b. Blown-in insulation- 12" depth-R30 11.66 SF @ 0.85= 9.91
128. Remove Carpet 11.66 SF @ 0.23= 2.68
135a. Remove Carpet pad 11.66 SF @ 0.09= 1.05
Bedroom 2 Height:7'7"
Door 5'9" X 6' 8" Opens into B2CLST
Door 2'9" X 6' 11" Opens into HALLWAY
Window 4' 11" X 3' 5" Opens into Exterior
DESCRIPTION QTY UNIT PRICE TOTAL
86. Remove Carpet 114.41 SF @ 0.23= 26.31
91a. Remove Blown-in insulation- 12"depth-R30 114.41 SF @ 0.75= 85.81
91b. Blown-in insulation- 12" depth-R30 114.41 SF @ 0.85= 97.25
134a. Remove Carpet pad 114.41 SF @ 0.09= 10.30
Master Bedroom Height:7'7"
Window 4' 11" X 3'5" Opens into Exterior
Door 2'8"X 6' 11" Opens into MASTER_BATH
Door 2' 10" X 6' 11" Opens into MSTR_CLST
Door 2'9"X 6' 11" Opens into HALLWAY
DESCRIPTION QTY UNIT PRICE TOTAL
87. Remove Carpet 189.58 SF @ 0.23 = 43.60
LAURA_CLOUSEI 4/21/2014 Page: 5
• •
CONTINUED-Master Bedroom
DESCRIPTION QTY UNIT PRICE TOTAL
92a. Remove Blown-in insulation- 12"depth-R30 189.58 SF @ 0.75 = 142.19
92b. Blown-in insulation- 12"depth-R30 189.58 SF @ 0.85= 161.14
133a. Remove Carpet pad 189.58 SF @ 0.09= 17.06
Hall Clst Height:7'7"
Door 4' 10"X 6' 8" Opens into HALLWAY
DESCRIPTION QTY UNIT PRICE TOTAL
93a. Remove Blown-in insulation- 12" depth-R30 6.89 SF @ 0.75= 5.17
93b. Blown-in insulation- 12" depth-R30 6.89 SF @ 0.85= 5.86
Mstr Clst Height: 7'7"
Door 2' 10" X 6' 11" Opens into MASTER_BEDRO
DESCRIPTION QTY UNIT PRICE TOTAL
94a. Remove Blown-in insulation- 12" depth-R30 20.24 SF @ 0.75= 15.18
94b. Blown-in insulation- 12"depth-R30 20.24 SF @ 0.85= 17.20
124. Remove Carpet 20.24 SF @ 0.23= 4.66
132a. Remove Carpet pad 20.24 SF @ 0.09= 1.82
Master Bath Height: 7'7"
Window 1' 11" X 4' Opens into Exterior
Door 2'8"X 6' 11" Opens into MASTER_BEDRO
DESCRIPTION QTY UNIT PRICE TOTAL
95a. Remove Blown-in insulation- 12" depth-R30 33.22 SF @ 0.75= 24.92
95b. Blown-in insulation- 12"depth-R30 33.22 SF @ 0.85 = 28.24
LAURA_CLOUSE1 4/21/2014 Page: 6
. .
• •
Entry Clst Height: 7'7"
Door 2' 1" X 6'8" Opens into ENTRY_HALLWA I
DESCRIPTION QTY UNIT PRICE TOTAL
96a. Remove Blown-in insulation- 12"depth-R30 4.92 SF @ 0.75= 3.69
96b. Blown-in insulation- 12"depth-R30 4.92 SF @ 0.85= 4.18
121. Remove Parquet flooring 4.92 SF @ 2.65= 13.04
Bathroom Height:7'7"
Door 2'8"X 6' 11" Opens into HALLWAY
DESCRIPTION QTY UNIT PRICE TOTAL
97a. Remove Blown-in insulation- 12" depth-R30 40.61 SF @ 0.75= 30.46
97b. Blown-in insulation- 12"depth-R30 40.61 SF @ 0.85= 34.52
Garage Height: Sloped
Door 3'X 6' 10" Opens into LIVING_ROOM
Door 8'X 7' Opens into Exterior
DESCRIPTION QTY UNIT PRICE TOTAL
138a. Remove Batt insulation-4" -R13 -paper faced 301.14 SF @ 0.18= 54.21
138b. Batt insulation-4"-R13-paper faced 301.14 SF @ 0.70= 210.80
Labor Minimums Applied
DESCRIPTION QTY UNIT PRICE TOTAL
1 28. Framing labor minimum 1.00 EA @ 124.50= 124.50
111. Heat,vent,&air cond.labor minimum 1.00 EA @ 153.19= 153.19
LAURA_CLOUSE1 4/21/2014 Page: 7
I •
Grand Total Areas:
3,055.39 SF Walls 1,357.74 SF Ceiling 4,413.13 SF Walls and Ceiling
1,327.94 SF Floor 147.55 SY Flooring 383.09 LF Floor Perimeter
0.00 SF Long Wall 0.00 SF Short Wall 489.67 LF Ceil.Perimeter
1,327.94 Floor Area 1,452.74 Total Area 3,055.39 Interior Wall Area
1,253.05 Exterior Wall Area 166.00 Exterior Perimeter of
Walls
0.00 Surface Area 0.00 Number of Squares 0.00 Total Perimeter Length
0.00 Total Ridge Length 0.00 Total Hip Length
� 1
5b2'34
LAURA_CLOUSE l
4/21/2014 Page: 8
0 d( r
,.
•
y
3
'''' ''.-', '-'" ' , . : : '...".-• . - . - .;/4 ;'''''''54- .*:,:.': ,,,i.....n,.26,- 4.,"'..,.--- -Tf::,"I'N''?•'41..:''.?' et;''''' - -r''' .
1 -
�
" i
•lc' 1 \ 1 0 '.',,'::;41.irc-'''''S':. ..,,.E>MY f'...4 1, .•... i';''.:," 4 1.:,i':.pk.
a-- ..,If
itl • \(,._j,,, ' ..',:s.L,r.,::::,,,,,...,-'. +'''''':.. . ',-:":;;,:'..;;::":,' 't:.,, 1:, .
A
l' r ,*:"-
w
v
.4
A d " "
••
,;,Cit,
•
i yyyy....-"1"'-'-'-",,',.;l
T
' I *'''''-i ,11.'a . 4 j.
fir '
1 r
..,._____,,..# ~
f {t } a ;
�� k
.gyp
s'1 r.. ,n4;•
a .:: 4,..,,,,:—..,1?..
v'w:'":*--- '4 lit,a .: ` S. . r
._. I .
f
t 0
I
I
1
1
- Ar'''
yr
n !1;
'KG v ?
.. -
•
•
4 4
A
f
d'
: sgON Co o JEFFERSON CO* i
-L.
DEPARTMENT OF COMMUNITY DEVELOPMENT
e
Date: q Time Received: /o.,k am/pm Mon. Tue. Wed. hu Fri.
Date: `/
BLD: 12 f—/'/ Contact Name:
Owner: r Contact Number: 360 ,Q4{ 42//
Address: 5O ClOhito fei--,z-- igC. 206
Notes: RA--- 1 '
Foundation Plumbing Framing Propane Tank Mechanical
Setbacks Under-ground Framing Under ground Furance
Footing Rough In Air Seal Above ground Gas
Stemwall Hydronic Exterior shear Exterior lines Oil
Straps Hot Water Htr Interior shear Interior lines Ducts
Post Hole Ventilation Appliance
Underfloor Gas/Wood stove
Man-Homes Insulation
Final Inspection
Setbacks Floor
Foundation Wall Address Posted
Block&Tile Ceiling
.14 Q45°N `O JEFFERSON CO� j��8 ,,.
q G
DEPARTMENT OF COMMUNITY DEVELOPMENT y
Date: 03 Time Received: 0749 a 41110 Mon. ! Wed. Thur. Fri.
/4
Date: /1�
BLD: /4 Ole)/ lob Contact Name:
Owner: ei_e1)GrCA Contact Number: 360 Z041 WO (7
Address: ,j"p "; ,y,41,0 P. 206
Notes: jl1ir'e.Ge-e-
Foundation Plumbing Framing Propane Tank Mechanical
Setbacks Under-ground Framing Under ground Furance
Footing Rough In Air Seal Above ground Gas
Stemwall Hydronic Exterior shear Exterior lines Oil
Straps Hot Water Htr Interior shear Interior lines Ducts
Post Hole Ventilation Appliance
Underfloor Gas/Wood stove
Man-Homes Insulation
Final Inspection
Setbacks Floor
Foundation Wall Address Posted
Block&Tile Ceiling
• •
• Inspections are required to be called in by 3:00 pm to receive an inspection the next day. Do to
staffing issues,at this time,we cannot guarantee that you will receive an inspection the next day.
day. Unless you receive a call from us, assume we will arrive on your requested inspection day.
• You may leave an inspection request 24 hours a day,and Inspections are available from
Monday through Friday.
We cannot determine the time we will arrive in advance. However, if you call our office the
morning of your inspection,around 9:00 a.m.,we can give an estimate of when the inspector will
arrive. Our general office phone number is 360 379-4450.
• An approved set of plans are to be on site with building permit for all inspections. If permit and
plans are not on site at time of inspection, a re-inspection fee must be paid prior to re-scheduling
another inspection.
• If no access, no inspections will be performed,and a re-inspection fee must be paid prior to
re-scheduling another inspection.
• Inspectors will not access a home that has personal affects inside when the owner is not present.
• Commercial projects require 24 hour notice for inspection.
,',DSO\ coG� JEFFERSON CCDY 0 Sk Ili oesdCora_ VC 4
� � DEPARTMENT OF COMMUNITY DEVELOPMENT Jl0�4u, a 055
''S��f rG'°
Date: q"-Z7 Time Received: 01.07 am Mon. Tue. Wed. hu Fri.
Date: g-
BLD: N- 74,. / Contact Name:
Owner: Contact Number: 360 Ej '-/0 i/
Address: 6-o 00X44 /94_ 206
Notes:
Foundation Plumbing Framing Propane Tank Mechanical
Setbacks Under-ground Framing Under ground Furance
Footing Rough In Air Seal Above ground Gas
Stemwall Hydronic Exterior shear Exterior lines Oil
Straps Hot Water Htr Interior shear Interior lines Ducts
Post Hole Ventilation Appliance
Underfloor Gas/Wood stove
Man-Homes Insulation
Final Inspection
Setbacks Floor
Foundation Wall Address Posted
Block&Tile Ceiling.
• BUILDING PERMIT 1
Jefferson County Department of Community Development
621 Sheridan Street, Port Townsend, WA 98368
(360)379-4450 FAX (360)379-4451
PERMIT#: BLD14-00161 Received Date: 5/6/2014
SITE ADDRESS: 50 JONATHAN PL Issue Date 5/6/2014
PORT HADLOCK, 98339 Expiration Date 5/6/2015
OWNER: LAURA L CLOUSE PHONE: 360-301-6068
50 JONATHAN PL
PORT HADLOCK WA 98339-9405
CHIMACUM CREEK EST
SUBDIVISION: Block: Lot:
PARCEL NUMBER: 943600024 Section: 2 Township: 29 N Range: 01 W
CONTRACTOR: NORDIC SERVICES INC PHONE: 360-792-2565
PO BOX 1492
BREMERTON WA 98337
Contractor's License NORDISII80QA Expires 1/1/2016
PROJECT DESCRIPTION: FIRE DAMAGE IN KITCHEN & LIVING ROOM REPAIR
TYPE OF WORK RES SQUARE FOOTAGE:
TYPE OF IMP REP MAIN:
VALUATION 5,800.00 ADD'L: HEAT TYPE
CODE EDITION: 2012' HEAT BASE: HEAT TYPE:
OCCUPANCY: UNHEATED: #OF STORIES:
OCCUPANCY: OTHER:
CONST TYPE: SHORELINE:
CONST TYPE: GARAGE: SETBACK:
DECK: BANK HEIGHT:
SEWAGE DISPOSAL:
WATER SYSTEM: Type Amount Paid By: Date: Receipt:
BEDROOMS: BATHROOMS: Permit $113.00 JLA 05/06/14 148598
Exist Exist: Plan Check $73.45 JLA 05/06/14 148598
Prop: Prop: State Building Code $4.50 JLA 05/06/14 148598
Total: Total: Total: $190.95
Directions to Site:
HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION
THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED
BUILDING INSPECTION HOT-LINE 379-4455.
Request must be received by 3pm the day before the inspection is needed.
Office Hours 9:00 am -4:30 pm MONDAY - THURSDAY
HOT LINE AVAILABLE 24 HOURS A DAY
•
Jefferson County Building Division Permit Number:
Applicant:
BUILDING PERMIT INSPECTION APPROVALS Applicable Code: International Building Codes
To schedule inspections, call (360)379-4455 no later than 3:00PM the day before the inspection is needed.
Requests received after 3:00 PM will not be scheduled for the next day's inspections.
ELECTRICAL PERMITS are issued by the Washington State Department of Labor & Industries.
The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection
Inspection Item Date Approval Signature Notes
fiRE /art/2 5
A final inspection will not be scheduled until all of the
following are completed and signed off by the applicable
Department:
• Building Permit Conditions are met
• Septic Permit Final/Complete for any building
containing plumbing
• Land Use Conditions met and signed off
• Public Works Permit Final(where applicable)
FINAL INSPECTION VVi f/o ocZaPAg'Ocr
FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED
THIS PERMIT IS VALID FOR ONE YEAR
r
0 0
Jefferson County DCD Building Division
Correction Notice
PERMIT NUMBER 19"- 00 14.
OWNER Id 4-(u 6e-
JOB LOCATION 5,) 0-6o/1-r 1-4A PJ Fl-
Inspection of this structure has found the following violations:
X/STl/J4 .N1e rigfig-GZDR I N HALL WA
7-4. BF 2641t4Dki CI ZZ fl rA-r.roA.
6P1441 f _ - _Aro /N 4 Gk
/?L.,L S./1 4 4 1 4 c P TC' tc>,6 —r:6 B 6 ifA£D
it)/,e5V /turd Et6-'4- es c, AUB'L. ON
oAre P1 Dte#rrei L-/ rr
i i
F I
,,,,++
L�..14GL ,g9,rZ. KL-`°/,tV.5 PLeT ,o L Iagi) iA,l?7
You are hereby notified that no more work shall be done upon these premises until
the above violations are corrected, unless noted otherwise. When corrections have
been made, call for inspection. Al
Date 9/2/9/ Inspect• �,._ �1,,�
BUILDING DIV N(360)379-4450 INSPECTION HOTLINE(360)379-4455
THIS NOTICE MUST BE KEPT WITH APPROVED PLANS ON SITE