SEP2013-00065
9sw IF Jefferson County Department of Community Development • 4 �> 621 Sheridan St., Port Townsend WA 98368, (360)379-4450 � ' " �i` SEPTIC PERMIT APPLICATION 0,BERIR: 'f r; � �, RONALD Sr E/ JUT IT IC I NC--{>v 4 I , E ` a 4-3-13 1 3 PHONE ( 340 ) 37a _ 4-gO35 SYSTEM DESIGNER G1 L LS EN D ES 16!V Designer Phone# 3!`,O '" 361 ®3.2-4 LEGAL DESCRIPTION: Section 1 Township 30N Range I % PARCEL# 00 I O 0.01 Subdivision Name Division Block Lot(s) Site address/Directions to site .2_6() } C P1 I N N 7 . ?O'RT TO%A)n E N b SOURCE OF SEWAGE/USE TYPE OF WORK WATER SOURCE Residential New $ Private X Residential ADU )4,, Modification Public Commercial Expansion I Community Upgrade Repair SITE SIZE 4,53 AU'S$ SYSTEM TYPE Partial Repair-(tank) (drainfield) Previous Evaluation Conventional )C Designate Reserve Area Yes# SEP 9d°-700 Alternative Redesign No SYSTEM DETAILS Number of Gallons/day .440 Soil type 4 (attach soil eval.) Application Rate .67 gal./sq.ft./day Drainfield Length 140 ft. Trench Width 3 ft. Trench/Bed Depth IS-30 in. Septic Tank size IC 6 0 gal. Pump Chamber size -- gal. TYPE OF SYSTEM E r& COn.;e.' 41 d yi By signing the application form, the applicant/owner attests that the information provided herein is true and correct to the best of their knowledge. Any material falsehood or any omission of a material fact made by the applicant/owner with respect to this application packet may result in this permit being null and void. I further agree to save, indemnify and hold harmless Jefferson County against all liabilities, judgments, court costs, reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the application that he or she requires prior notice. Inspections shall occur during regular business hours. Initial here if you require notification before entry Appeal–A person aggrieved of a decision of the Health Officer may appeal. Appeals shall be submitted to the Health Division in writing within fifteen days after receiving written notice of the decision. DISCLAIMER-This application is for an on-site sewage system that meets the state and county standards in effect on the date of application. This application for an onsite sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any futture plication will be separately judged by the rules and laws in effect at that time. 114,4- `3 gi/3 Propel-VI-Owner Signature Date FOR OFFICE USE ONLY I i 11 1 PARTIAL ASBUILT 1q/l FINT A O ED INSP/PUMP TEST PUD If I1y I?A11 11 ALL HOLD REQ.MET r ‘/, Date J' 1� Fee , (' Rec# Check# Case#SEP /3— - ' t JEFFERSON COUNTY PUBLIC HEALTH 615 Sheridan Street•Port Townsend•Washington •98368 www.jeffersoncountypublichealth.org alone 3bU-385-9444 I-ax 3(iU-3/9-4413 I ON-SITE SEWAGE DISPOSAL PERMIT PERMIT #: SEP13-00065 Date Received: 06/04/13 Date Issued: 07/10/13 SITE ADDRESS: 260 MC MINN RD Date Expires: 07/10/16 PORT TOWNSEND, WA 98368 APPLICANT: RONALD STRANGE PHONE: JUDITH A KING 260 MCMINN RD PORT TOWNSEND WA 983689646 LEGAL DESCRIPTION: S7 T30 R1W TAX 10(LESS CO RD R/W) PARCEL#: 001072014 Section: 7 Township: 30N Range: 01 W DESIGNER: BERNT ERICSEN PHONE: 360-301-0324 293 PINECREST DRIVE PORT TOWNSEND WA 98368 SYSTEM DESCRIPTION: CONVENTIONAL TRENCH No. of Gallons per Day: 240 Type of work: NEW Drainfield Trench Septic Tank Length: 140 feet Width: 3 feet Depth: 18 inches Size: 1,000 gallons DISCLAIMER-This approval is for an on-site sewage system that meets the state and county standards in effect on the date of application. This approval for an on-site sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. All construction and development activities must comply with all permit conditions,state and local codes, and Recommended Standards and Guidance documents in effect when the permit is issued. The property owner is responsible for the accurate location of all property lines.Any removal of or major disturbance of soil in the primary or reserve drainfield area may create site conditions that are unacceptable for the installation of a sewage disposal system. Any change in drainfield or tank location may invalidate this permit unless prior approval is obtained from the Jefferson County Environmental Health Division. If during excavation or development of the site an area of potential archeological significance is uncovered,all activity in the immediate area shall be halted, and the UDC Administrator shall be notified at once. Permit issued to CONSTRUCT,ALTER, REPAIR OR MODIFY AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM IN JEFFERSON COUNTY, WASHINGTON This permit is issued for a period of three years (unless otherwise stated above) in accordance with Jefferson County Rules and Regulations for On-Site Sewage Systems, codified in JCC 8.15 as amended. This permit may not be renewed. Jefferson County Environm al Health Specialist This permit with conditions must be onsite during all phases of construction HEALTH DEPARTMENT MUST BE CONTACTED FOR FINAL INSPECTION. SPECIAL CONDITIONS APPLY - SEE ADDITIONAL PAGES CONDITIONS OF APPROVAL - PERMIT NO.: SEP13-00065 1.) The existing transport line connected to the existing septic system must be abandoned and doccumented by the septic system designer prior to final approval of this permit. 2.) Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box. 3.) Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS. 4.) Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start. 5.) H -An asbuilt drawing and certification of completion by the Designer is required prior to final approval. 6.) H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT 7.) Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system. 8.) 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components. 9.) Divert all sources of drainage, including roof drains away from septic tank and drainfield area. 10.) Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required. 11.) All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued. 12.) Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site. 13.) The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. SEP13-00065 Page 2 of 2 \\tidemark\data\forms\F_SEP_Permitmod.rpt 7/10/2013 CONVENTIONAL SYSTEM ASBUILT INSPECTION REPORT INSTALLER ErtCS '► Ex. (To but k i haw►) PARCEL# 00167�0I Li Permit Owner 'Ronak S+range,/* t Li-Ii 1 in9 Permit # -S e f 13 -• ( c ABSORPTION AREA: DRAINFIELD TRENCH E TRENCH N TANK #OF #GAL/ LENGTH I WIDTH 3 DEPTH SIZE I BEDRMS ot DAY 02 lif 0 Tank Shroud/ IF PUMP AND PUMP CHAMBER REQUIRED: Size Screen Float Arrangement High water float—distance to top of tank/emergency storage Dose drawdown (#of inches) #Gallons/Dose Timer/Dose Counter info Pump Size/Manufacturer I CERTIFY THIS ONSITE SEWAG SYSTEM)IAS INSTALLED AS DESIGNED, PER PLAN APPROVED '7-10° /3 ail, i' ti -6 -1 DATE APPROVED 1)t5r'usner SIGNATURE DATE See a f a�ch�.cQ. ��R cc b,-L D Maul t'r '. NO V 14 2014 • s cnx mm -om -0v -Ozzz v - wD, ''14 2y4, 0 0 0 0 0 0 m > u u II II n u m m N N NO N —, 3 — O jcri W cD 3 U) -v a 1 co ` w () r • Z 3 as I ,' 3 N - m • D 3 N f�j . i 3 < m m a m 4J4,' ,/ ,.' n o F < Ts � � cn az- 3 p D � ,' +•,, 4,,i ='. 0- T o m tDn 0-, v co .'� \4' 0, m v- 0 o -N rn r „ / Cam) (A CO o m = I- 7 o t-� 1} i m D '�, \ 1 N i n 1} ea -I m Z x " , 1 W • �' Z iI n \ m m>i = eG o \ * 1 J �N a OWN\ O j^ 1 N O C N -�- 'OZ 1 CA) k fEfl �° o ■ 7.: O = CO"I'• 1� 1W il. i� ■ o ., � MmN ' ! A� m i 1 � 6®� N v 7 � a + _ W m M g o O I = (� A 7� ��2 (n .0 U m N1 N NcD 1 11 r 1 3mtDO �7 , 1 W oa--m O 1 \ 1 O fN w O �l� ii i 1 ci,N) at 0. c) O 8: N.1 ' N W D �cs ' �o >q a e�pN> 444/ cn 125' / 313.07' Ir I-1 / S 1°54'06»W �/R KKKKKKK DDDDDDD K c' i ao 0 0 0 0 0 0 0 0 0 0 0 0 0 0 m o 0 e' C IG� mm00W = G) mmvow c 3 0 / y C 11 p 11 II 11 II II II p 11 II p p II cp - 0. i CD -"10o .1rno) cn V' W 0) o 3 W -`j � 3 = v_' Qc000rnco -I'' ) 0) CYICO " v CD do 05 d) A Co =0) 0 EGA ket elooSN to GS • /001 t 17 L- C 0 Li0 /� \� 0 C o M.90,179.I.S / / \■ LLU O ,L0.£1.£ / • gf � m `d ; W A re I I o ; II 04 S104404300 WS 1 ISIO‘111 he f t0 i I. ,., CD O N ,.., C O >N 1 _2 C- O a CO CC w CC C I- N Z - N N -co Z O co G to co N. co z N 0 Z k 2 a Z } m co p Z m L c "� Q W 2 G 2 ® o m CO a a.~ cOp IA .r► cc +Jt Z 0 M w �.C`� ... : .A cv Z Q,_ , ti :' _p W N (n t ►� JV�,r V F- p 3 e ‘ ,®` �r1N O Q Ill • Iii 4R.. . .'• Join- w 44- E�,�‘"‘ C�`�, 'A Z H La N I- 11‘\fi! W rn Q Li m o 0O 00 ,L� ."-C- CO c0 --) 0J _N=*- -->7 / .cn 0C° 73 ,-S i . jpj: N N �N CD D � o c 0r- Q en, WI o omQ ° rn �o � wtn r.' \) // li:// ../,' -n T., ` sumw � y0 � o�o ,iDZ m ..,.• . K I L, — �, \ o' ,'�I \I' +' v l) 5 x 0 w . � ' �w / � C4 > Z N . O 7:1 N L+ '' ,,'/ ,/ I � Tmj ji ! m I \ 1 1'Q I m W 0 D X Nm — ,*"o -0 0 oII 1 10 I (D -< 0 mQ p n I p E o c 5 y o o i VS N O I-0 1 o 0 om ' -6 -11 m3 -� 5cos 1003 0 jai I� \ J ` m �\ N4 . 11 zQ ° zm IZZ01�o IQ• IQ `\� aoc s o o m r- 1 w m 0 m � o 1CD 0- = I^ I^ m v w3 OoS 1 cones o .� T3 Z Ip ICI 00 ` co, i co 1 0= m m -. N 1 I O = W W. N '% a ( - v ° w x Mow- a®► - N y CD X O - IS I - I co (� m 1 N A, I r n °c !!i li' 0 w w CD p I I O 1 s I i i � m ► • CO� m ox / Z � m I co 01‘ Oaa Kv rn �• ft „1,, mcQ g iso / 0 W Dm -.0 'aV—A* /' X01 m CC, / CD O -0 c0D 0 }1.W , .., ,.44 'f Alk ‘ v °- QQ / C) mm 1,+ /Q r , ��l: C 0 Z r o / I a r -44,,,.4") C)125q. a;, 00 313.07 �f 1 , � Q S 1°54'06"W • = •CD CO Q CD CO •,,,,s CO � KKKKKKKK DDDDDD > » m Q �''% . 00000000 000000000 w � ® :� .. r �• = G) mm() 0a rc' = G) mmv0C0 a ,,' 0* II II a 11 II II II II 11 11 II II II u u u u (p ON .4cn " 0302C° OOOCON V ODOR 0 CD 0) 0) 0 0) 02 0 Z. • Ins. lY STRANGE / K1t ' QOIO71.0 / 4 e.- �--=',-, LID.1..MIRMSTEMITSKiii,„ I - 245' sir 'N: - - ,,t,FausHer-"E. f I mi, . t J T ___f iill MN . £-- -- I1 m. .. - �°- „am : � .■� ..r Man s- P„m 1 _ .. ISM iI mom i r+1 c: '\ y r � f .. " — , y� �� ti3 �15 Stru��l0n p roved for �l c4F BI RNT PAUL RICSEN f�i� if_. IC NS b. •I EFi • ti, Date wr6.6.4h4 00 i`O�l l..!w \r:+e S..'F ,, , Trench Profile ( No Scale ) 3 -13 (See Notes For Details) Finish Grade Geotextile Filter Fabric Native Bac kfill inspection Port I El 4°ASTM D2729" e ♦. .. . ! Yz Yz Y : 1y !t L • 1'y ;r. 1 1 •R R R :: i k� z z t,} z- ate. t s ; ' End Trench "v" Box 4"ASTM D2729 4" 15T ivt 34'34 To Drainfield NM �rsrn 5: -ic.Ya„k {Solid} ;.X.:•;!:,-:•"..!"...;•:•:•:•;!�..- 3/4"to 11/2" ' Clean Drainrock R z i ' ...- 1 % 6"Min.Under Pipe • s ,4 0 ,, X0 a i . , . f;,4") i /"' i4i SRL DESIGN iRtff UL ERICSEKi 4 RG'E DISPO"0,;..L.. ... c '4.... !4 •r •nStCUOtlotl •l . e,. ,� App 1 6..3- 3 pate Ronald Strange / Judith King 001072014 Project Description Install "New" two bedroom gravity conventional septic system for existing residence. Septic Tank Install 1000 gallon two compartment septic tank. Install water tight risers to grade on all tank lid openings. Install outlet baffle filter ( Orenco FTiP 0418-W ) or equivalent. Tank to be set on 6" of "Pea Gravel". Transport Line Install 4" 3034 sewer pipe from building stub out to septic tank @2% minimum grade and from tank to new "D" box and to drain lines @ 1% min. Delete existing sewer line from existing residence to SEP 90 — 700. "D" Box Install 4 hole "D" box on poured in place concrete pad on undisturbed soil with riser to grade. Install speed-levelers and water level prior to designers "as built" inspection. Drainfield Install 2 ( 70' x 3') laterals as shown on plans. Install inspection ports ( inside 6" round valve boxes ) with risers to grade within 5' of each end of lateral ( Gravelless 1 Chambers ) Install straight tees 20' from beginning and at end of each lateral ( Gravel Trenches ) If Gravelless Chambers used install Digger's 20 Gauge, Hot dipped galvanized wire mesh with 3/4" hexagonal openings over entire trench bottom under chambers. Trench depth 18" to 30". ( TRENCH BOTTOM LINE 1 TO BE 3.45' ( equals 18" depth at "B" see plot plan ) BELOW TOP OF DECK " BENCH MARK" ON PLOT PLAN.) NO FOOTING OR DOWNSPOUT DRAINS TO BE INSTALLED LESS THAN 10' UPSLOPE OF DRAINFIELD. Water Lines Existing water line route from well to existing residence is unknown. If water line is encountered take measures to obtain minimum 10' separation from septic components where possible. Water faucet at RV Hookup needs to be moved to obtain 10' minimum from septic tank and transport line. Downspout Divert downspout at NW corner of residence away from new septic tank and drain field area. Inspections Designer needs to be contacted for a pre-construction meeting prior to construction to discuss details and to set up schedule for inspections. Designer is responsible for submitting "Record" drawing, and must be called prior to backfilling system.. General Construction Notes 1. The work described herein consists of construction of an on-site wastewater system. 2 2. The contractor shall be knowledgeable and experienced in the construction of this type of wastewater system and shall hold a valid certificate from Jefferson County Division of Environmental Health. "Approved" septic plans must be on site during construction. 3. If during the installation of the system the contractor finds soil conditions that may lead to premature failure of the system, construction shall be terminated immediately and the designer notified. Such soil conditions may include groundwater, fill, clay, highly compacted soil, bedrock or excessively permeable soils. a. Any inconsistencies, errors, or omissions that, in the opinion of the installer, would compromise the quality of the wastewater system shall be reported to the designer prior to construction. 4. Backfill in traffic areas shall be pitrun gravel and compacted. All gravity pipe shall conform to ASTM D 3034. All gravity and transport pipe shall be bedded, using native or imported material free of rocks, debris and sharp objects. 5. All exposed soil shall be seeded and mulched prior to the final inspection. Seed shall be spread at an approximate rate of 10 lbs. per 5,000 sq. ft. 6. The installer shall be responsible for constructing the system according to plans and conditions of permit and shall be responsible for its proper operation and function for one year. The owner shall be responsible for operating and maintaining the wastewater system in accordance with WAC 246-272A-0270. 7. Any changes, substitutions, or deviation from these plans shall be approved by the designer and by the Jefferson County Environmental Health Department. 3 8. The installer shall grade to divert all surface water runoff away from tanks and drainfield/reserve areas. 9. The bottom of the trench or bed may be inspected by the designer prior to placing drain rock and shall not exceed +/- 1/2" from level. Place filter fabric over drain rock prior to backfilling. 10. Setbacks to all known water lines shall be a minimum of 10'. No crossing of water lines with any septic component shall be allowed, except as included in septic design approved by Jefferson County Health Department. 11. Setback from the house foundation wall shall be 10' minimum to drainfield, 5' minimum to tanks and 2' minimum to non-perforated sewer pipes. Water saving appliances, fixtures, and practices are to be used. 12. The septic and pump tanks, drainfield and reserve areas are to be protected from vehicular traffic or mechanical disturbance. 13. The designer is to provide the as-built and letter of certification. 14. This system has been designed in accordance with WAC 246-272-A-0270 and the most current Department of Health "Recommended Standards and Guidelines for Pressure Distribution Systems," and has been approved by the Jefferson County Health Department. Nevertheless, negligence or improper action on the part of the users could result in the premature failure or malfunction of the system or its components. 4 �0q,9 . A�il,� JEFFERSON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT j� %.$ 621 SHERIDAN ST., PORT TOWNSEND ,WA 58368, (360) 379-4450 pJr;" ` ,•Lai R SOIL EVALUATION 0 f)'AR PROPERTY OWNER ©n aid_ S+ra i e / J LC -tit 1\I **BE. io �s A �J < � RNT�Ul E�ICEN•••. 11 Jr ( idt_b I) "I N ` • SYSTEM DESIGNER C. 'r(C,se1 -1).e g 11 `®,v w. ►.a►..�o.a.N.,..�,R�, E?(PI•r 6, v jr . t ,I, 4-3/3 LEGAL DESCRIPTION: Section 7 Township Range 11A! Parcel # ©O I 67.201 7 Subdivision Name Division Block Lot(s) Date Logged: jj 0_ 13 Logged R gg By: l`'�xn�- E ri G s eci Include sou textural characteristics and the depths at which significant changes occur. Be sure to include depth where mottling or impermeable layers occur. SOIL LOG #1 SOIL LOG #2 0 to 10 in. Vg LS 4 G AvEL. (j tog in. BR L.S . I b to A, in. TPV Fkl--L25 511 i) TA/3 $ to 67 in. TA) FM 5)1/4)1) T 4 etto to 8q in. TA) 67�V. i ,\)'-GR S slob) T2 to in. to in. Winl Ti I LEIJSbS to in. Anticipated water table>'` in. , Anticipated water table>(?' i.w Roots to '7O inches u/\ Roots to 4..2... inches Health Dept. Comments F' Health Dept. Comments SOIL LOG #3 C7 SOIL LOG #4 6 to - in.1)I< �3R SL. 0 to 3 in.•D k `3R S L Li to / in. -8,-K L..5 Tit 3 to g in. -87i L S 1l to 48' in. TA) FA) S/JD S to 44, in TA) FM—T11 r 50) T 4 hi$ to '17 in. TA) F — C' Z S S llrb T3 to in. Anticipated water table'777 in. Anticipated water table 7/04 in. Roots to ifir inches Roots to tit inches Health Dept. Comments Health Dept. Comments SOIL LOG #5 SOIL LOG #6 0 to _in. 'DK 'Bre fV S(.._ to in. '7 to '(I in. T4(J (IV'- M E SIJb T to in. _ 45 to 71 in.))i ST al 0 T. to in. to in. to in. Anticipated water table 71 in. Anticipated water table in. Roots to if? inches Roots to inches Health Dept. Comments Health Dept. Comments H:UNFOHLTH SOILFRM1roo ONSITE SEWAGE DISPOSAL SYSTEM DESIGN 60 /0i i .0 i4 Date 6 - 1-- Property Owner WON! A Lt STR A•N 6 E/J u 1 1 11.1 k LN System Designer EK I Cs EN 1) E.$ 1 hl Legal Description: Section 7 Township 3ON Range I uJ Subdivision Name Division Block Lots) 1. CALCULATIONS If for residential use: Number of Bedrooms: x 120 G.P.D. = .24-0 total G.P.D. If for non-residential use, attach calculations used to determine G.P.D. Soil texture waste water application rate . 57 G.P.D./ft. squared (see page 214 of the EPA Design Manual) DRAINFIELD SIZING: Absorption area: its() square feet (total G.P.D. G.P.D./ft. squared) Trench or bed width 3 feet Trench or bed length , lineal feet (sq. ft. - trench or bed width) I(. APPURTENANCES Septic Tank Size WOO gallons Pump Requirements (If Necessary) Elevation difference in feet Friction loss Pump capacity should be G.P.M. at — T.D.H. Number of doses per day — Dosing volume gallons Pump chamber size "-"' gallons nor i gc; BERIVTAUL ERICSEN HP;homelptncntrUnfohith\sewdsn r�a.: � 3-i3 • III. DRAINFIELD CROSS SECTION D /I;_,t, a" Dr.:.. Rack NATIVE SOIL A E i C T IPE?ME/3 E Ir. -- , SEA.SCNAaL SA.TU'RATIC'; A. Trench Depth l g 36 inches B. inches of drainrock below pipe C. ? 3 4 inches of vertical separation from trench bottom to impermeable material/seasonal saturation D. inches of fill (if needed) E. Trench width 3 6 inches NOTES: ATTACH°, ETAILrD_ DESIGN OF SYSTEM