Loading...
HomeMy WebLinkAboutBLD2015-00060 - MECHANICAL • • BUILDING PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD15-00060 Received Date: 3/2/2015 SITE ADDRESS: 83 GRENVILLE CT Issue Date 3/2/2015 PORT TOWNSEND, 98368 Expiration Date 3/2/2016 OWNER: PETER G MAC LACHLAN PHONE: 360-379-5677 CHRISTINE M MAC LACHLAN 83 GRENVILLE CT PORT TOWNSEND WA 98368-9525 9650 SUBDIVISION: Block: Lot: PARCEL NUMBER: 965000195 Section: 27 Township: 30 N Range: 1V1 CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 PROJECT DESCRIPTION: NEW MECHANICAL PERMITS INSTALL NEW HEAT PUMP TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC MAIN: VALUATION ADD'L: HEAT TYPE: CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: OCCUPANCY: UNHEATED: #OF STORIES: CONST TYPE: OTHER: SHORELINE: CONST TYPE: GARAGE: SETBACK: DECK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: Type Amount Paid By: Date: Receipt: BEDROOMS: BATHROOMS: Permit $152.00 SRE 03/02/15 154134 Exist: Exist: State Building Code $4.50 SRE 03/02/15 154134 Prop: Prop: Total: $156.50 Total: Total: Directions to Site: HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. Request must be received by 3pm the day before the inspection is needed. Office Hours 9:00 am - 4:30 pm MONDAY - THURSDAY HOT LINE AVAILABLE 24 HOURS A DAY I Jefferson County Building Division Permit Number: BLD15-00060 Applicant: MAC LACHLAN BUILDING PERMIT INSPECTION APPROVALS Applicable Code: 2012 International Building Codes To schedule inspections, call (360)379-4455 no later than 3:00PM the day before the inspection is needed. Requests received after 3:00 PM will not be scheduled for the next day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Miscellaneous /Z,7/ /5 A final inspection will not be scheduled until the following are completed and signed off by the applicable Department: • Building Permit Conditions are met • Septic Permit Final/Complete for any building containing plumbing • Land Use Conditions met and signed off • Public Works Permit Final(where applicable) FINAL INSPECTION 14,S , FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR Err\CLd rU Oat in to LV 1 S' • BLD15-00060 BUILDING PERMIT APPLICATION Review Type: Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD15-00060 Received Date: 3/2/2015 SITE ADDRESS: 83 GRENVILLE CT PORT TOWNSEND, 98368 OWNER: PETER G MAC LACHLAN PHONE: 360-379-5677 CHRISTINE M MAC LACHLAN 83 GRENVILLE CT PORT TOWNSEND WA 98368-9525 9650 SUBDIVISION: Block: Lot: PARCEL NUMBER: 965000195 Section: 27 Township: 30 N Range: 1V\ CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 REPRESENTATIVE: PHONE: PROJECT DESCRIPTION NEW MECHANICAL PERMITS INSTALL NEW HEAT PUMP TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC MAIN: VALUATION ADD'L: HEAT TYPE: CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: Exist: Prop: Prop: Total: Total: Routing Date: Type Amount Paid By: Date: Receipt: Approved/Date Permit $152.00 SRE 03/02/15 154134 State Building Code $4.50 SRE 03/02/15 154134 APPROVED Total: $156.50 MAR 0 2 2015 Jefferson County DOD \\tidemark\data\forms\F_BLD_App_Bld.rpt 3/2/2015 • I ON ���r, � (-' , DEPARTMENT D COMMUNITY DEVELOPMENT '1 S'lenciar,Strct€ P,ql"1 7 ::{t(?,\\ \()S368 -< 1<1..<,6f!„3`'9.44111 ( Fr,:301.; ').x113 \,b C1\' t{ Cf ELF. Ci'..__a..,:, C .'at 71t;t! t=L Cl(J 1C1f71[ MECHANICAL AL I.. R i.T APPLICATION Steps in the Permit Process: -Review required submittal items to ensure all information is completed prior to submitting application. -Mechanical Permits can be mailed into our office-and do not require an appointment. -Fees are due at time of submittal, Mechanical permits are generally issued within 5 business days. For Department Use Only Receipt#:153...I I by Date: �%l S Related Application#s: Payment#: 19. .co Is this application for use in a Mobile/Manufactured Home? * If Yes: A permit from Washington State Department of Labor and Industries, not Jefferson County, is required for appliances installed within a mobile/manufactured home. L&I -360-417-2702 * If No: Complete this form and make an appointment to submit to Jefferson County Permit Tech 360-379-4450 Required Submittal Items-for propane tank only General Site plan—showing propane tank, lines, and distance from tank to all existing structures. _Required Submittal Items-for Solar Panel installation only Complete first page and signature block only of Mechanical Permit Application. A complete solar panel supplemental application. Site Information Assessor Tax Parcel Number: i ,(C ax-) 1 6? s Site Address and/or Directions to Property: Q7) ( y ,r1V I Ll .. e...001.-4-- p .-r Access (name of street(s) from which access will be gained: Description of Work: I 1,1C -1-71-1.A....- 0 6 C. N t-I-(lilt lo o /)/9 Sqc / Property Ow er , Name: i A AI Address: 1 Al g Phone #: g(. Jyq, — 5j‘, !#- E-mail Address: m Please contact Authorized Agent/Representative with project info. Z Property Owner Signature: Date: Applicant/Contractor: Authorized Agent/Representative Name: ■l I, , .[w"4r is A Phone #: / A �' — j E-mail Address: License #: AI e.,F L 1 .e?o U,6(� Expiration Date: 6-2.0 i S. Mechanical Application 1 0 • Heat Source Electric 'V/ Heating Oil Propane* Wood Indicate Quantity and Fixture Types Below *Propane is prohibited in Quantity Fixture Type Description hazardous locations such as Fan Bath Fan and/or Exhaust Fan basements or pits or Clothes Dryer Clothes Dryer with Exhaust Vent anywhere "heavier-than-air" Cook Stove Cook Stove, Range Hood Exhaust gas can unsafely collect. Fireplace-Gas Fireplace-Gas or Gas Log Insert *Propane tanks over 125 Fireplace-Wood Fireplace-wood,Wood Stove, or gallons require a minimum Pellet Stove setback of 10 ft. from Electric Furnace Electric Furnace or HP+/- Ducting property line and buildings, Propane(LP) Gas Furnace Propane Furnace+/-Ducting and a site plan must be submitted with the Water Heater-Gas Gas WH Vent and Combustion Air application showing the Gas Pipe System Gas Pipe System LPG/Oil setbacks. If propane tank is Propane Tank LP Fuel Tank(#gallons: ) over 500 gallons, a site plan is Heat Pump required to accompany this Generator application, and a separate Air Conditioner Fire Code approval is also required. Installation manual must be on site at time of inspection or a re-inspection fee will be charged. By signing this application form, the owner/agent attests that the information provided herein, and in any attachments, is true and correct to the best of his, her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in making any issued permit null and void. I further agree to that all activities I intend to undertake or complete associated with this permit will be performed in compliance with all applicable federal, state and county laws and regulations and I agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections. Applicant may request notice of the County's intent to enter upon the property for visits related to this application and subsequent permit issuance. G . Signature: ,i 1 OA- Print Name: ),Vt C +i t (,,y( _. Date: /1--11+1 6^-7 OFFICE USE ONLY Building Permit Fees Mechanical Permit fee(tank swap,woodstove,furnace,etc) $152.00 Propane- Lines,tank, and appliance (add') $76.00) Project Scanning Fee $19.00 1 Total Fees* s I L, *Additional fees may apply. *ece-iff IsLi i (-1. Mechanical Application 2 19 Z It"5 CD • This combination qualifies for a Federal Energy Au ..ii CERTIFIED® Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 6750459 Date: 2/17/2015 Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWV8024A1 Indoor Unit Model Number: *AM8C0B30V21 Manufacturer: TRANE Trade/Brand name: TRANE Series name: XV181 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent,third party testing: Cooling Capacity(Btuh): 23800 EER Rating (Cooling): 13.00 SEER Rating (Cooling): 18.00 Heating Capacity(Btuh) @ 47 F: 20000 Region IV HSPF Rating (Heating): 10.00 Heating Capacity(Btuh) @ 17 F: 16800* *Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and v. confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better"" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2014 Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 130686938609075933 • 0 1 l= .c--- ---), ...., (.,-^^ /� 1 ! t d F1- v ! . I AIR FAO Load Short Form Job: Date: NEAT/N6 CO. Entire House By: INDOOR AIR EXPERTS Air Flo Heating Co 221 West Cedar Street, Sequim,WA 98382 Phone: 360.683.3901 Fax:360.683.3971 Web:www.airfloheating.com Project Information For: MacLachlan Design Information Htg Clg Infiltration Outside db (°F) 25 76 Method Simplified Inside db (°F) 70 75 Construction quality Average Design TD (°F) 45 1 Fireplaces 1 (Average) Daily range - M Inside humidity (%) 30 50 Moisture difference (gr/Ib) 17 15 i HEATING EQUIPMENT COOLING EQUIPMENT Make Make Trade Trade Model Cond AHRI ref Coil AHRI ref Efficiency 0 HSPF Efficiency 0 SEER Heating input Sensible cooling 0 Btuh Heating output 0 Btuh @ 47°F Latent cooling 0 Btuh Temperature rise 0 °F Total cooling 0 Btuh Actual air flow 800 cfm Actual air flow 800 cfm Air flow factor 0.037 cfm/Btuh Air flow factor 0.055 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.93 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft2) (Btuh) (Btuh) (cfm) (cfm) upper floor 753 5939 4013 218 221 Main Floor 1388 15873 10532 582 579 Entire House d 2141 21812 14545 800 800 Other equip loads 0 0 Equip. @ 0.81 RSM 11781 Latent cooling 1177 TOTALS 2141 21812 12958 800 800 Bold/italic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 7th Ed. 2015-Feb-19 07:55:58 Wrightsoft` Right-Suite®Universal 2015 15.0.03 RSU02757 Page 1 ACCA S:\Company\Wrightsoft HVAC\Project\Default 1.rup Calc=MJ7 Front Door faces: N Parcel Details Page 1 of 2 ID Jefferson Coun ,. --o weaTer Station Home County Info Departments Search Parcel Number: 965000195 1 SEARCH Parcel Number: 965000195 Printer Friendly Owner Mailing Address: PETER G MAC LACHLAN CHRISTINE M MAC LACHLAN 83 GRENVILLE CT PORT TOWNSEND WA98368-9525 Site Address: 83 GRENVILLE CT PORT TOWNSEND 98368 Section: 27 School District: Port Townsend (50) Qtr Section: NW1/4 Fire Dist: Chimacum (1) Township: 30N Tax Status: Taxable Range: 1W Tax Code: 0111 Planning area:Tri-Area (4) Sewer: Drainage: Bank: View 1: View 2: Zoning 1: Zoning 2: Zoning 3: Sub Division: 9650 - KALA POINT 3-8 Assessor's Land Use Code: 1100 - Residential - Single Unit Property Description: KALA POINT #6 LOT 292 Tax, AIV, Sales, Photos, and Permit Data Bldq Data Map Parcel Plats&Surveys Septic Monitorinq Info ; _.. Jennison County HOME I COUNTY INFO I DEPARTMENTS I SEARCH Best viewed with Microsoft Internet Explorer 6.0 or later Windows - Mac http://www.co.jefferson.wa.us/assessors/parcel/parceldetail.asp?Parcel N0=965000195 3/2/2015 AIR FLO HEATING COMPANY. • Page 1 of 2 lio:i e Inic:io an Espanol Contact ;Search L&l � A-7 hndex Help My Secure I.&I Safety Claims&Insurance Workplace Rights Trades&Licensing Washington State Department of Labor & Industries AIR FLO HEATING COMPANY INC Owner or tradesperson 221 W CEDAR BEQUETTE,MARK A S WA 98382 3600-683--683-3901 Principals CLALLAM County BEQUETTE,MARK A,PRESIDENT BEQUETTE,SANDRA A,VICE PRESIDENT BERSON,JOEL R,SECRETARY FULLAWAY,MICHAEL (End:04/01/2010) Doing business as AIR FLO HEATING COMPANY INC WA UBI No. Business type 600 347 761 Corporation License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties Heating/Vent/Air-Conditioning and Refrig (HVAC/R) License no. AIRFLI*206DG Effective—expiration 03/07/1980—04/25/2016 Bond CBIC $6,000.00 Bond account no S15215 Received by L&I Effective date 02/05/2010 02/01/2010 Expiration date Until Canceled Bond history Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no 44CL483619 Received by L&I Effective date 04/18/2014 04/25/2014 Expiration date 04/25/2015 Insurance history Savings https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 3/2/2015 AIR FLO HEATING COMPANY. Page 2 of 2 No savings accounts during the previous 6 year period. • Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 351,432-00 Doing business as AIR FLO HEATING COMPANY INC. Estimated workers reported Quarter 4 of Year 2014"21 to 30 Workers" L&I account representative T1/FEARAED FEROZE(360)902-4797-Email:FERH235@lni.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Citation issue date 07/24/2012 Violations Inspection no. 315954529 Location 125 Horizon View Dr. Sequim,WA 98382 Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 3/2/2015