Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2015-00067 - HEAT PUMP
• BUILDING PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD15-00067 Received Date: 3/6/2015 SITE ADDRESS: 40 CEDARVIEW DR Issue Date 3/9/2015 PORT TOWNSEND, 98368 Expiration Date 3/9/2016 OWNER: JOE &JOAN WALLACE PHONE: 360-344-2756 40 CEDARVIEW DR PORT TOWNSEND WA 98368-2502 9650 SUBDIVISION: Block: Lot: PARCEL NUMBER: 965000316 Section: 27 Township: 30 N Range: 1\ CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 PROJECT DESCRIPTION: NEW MECHANICAL PERMIT INSTALL HEAT PUMP AND AIR HANDLER TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC VALUATION MAIN: CODE EDITION: 2012 ADD'L: HEAT TYPE: HTP OCCUPANCY: HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: SETBACK: DECK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: Type Amount Paid By: Date: Receipt: BEDROOMS: BATHROOMS: Permit $152.00 SRE 03/06/15 154142 Exist: Exist: Permit $4.00 SRE 03/09/15 154145 Prop: Prop: Total: $156.00 Total: Total: Directions to Site: III HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. Request must be received by 3pm the day before the inspection is needed. Office Hours 9:00 am -4:30 pm MONDAY - THURSDAY HOT LINE AVAILABLE 24 HOURS A DAY II Jefferson County Building Division Permit Number: BLD15-00067 Applicant: WALLACE BUILDING PERMIT INSPECTION APPROVALS Applicable Code: 2012 International Building Codes To schedule inspections, call (360)379-4455 no later than 3:00PM the day before the inspection is needed. Requests received after 3:00 PM will not be scheduled for the next day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Mechanical Systems "th.4„,11c— 9— Miscellaneous lanning Approval A final inspection will not be scheduled until the following are completed and signed off by the applicable Department: • Building Permit Conditions are met • Septic Permit Final/Complete for any building containing plumbing • Land Use Conditions met and signed off • Public Works Permit Final(where applicable) FINAL INSPECTION -3\2A FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR 6100vkli -11.1' 1A'') k, . 1(.1115 S • CONDITIONS for Building Permit# : \\tidemark\data\forms\F_BLD_Permit_BIdg.rpt 3/9/2015 BUILDING PERMIT APPLICATION BL Review vT 067 Type: Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD15-00067 Received Date: 3/6/2015 SITE ADDRESS: 40 CEDARVIEW DR PORT TOWNSEND, 98368 OWNER: JOE &JOAN WALLACE PHONE: 360-344-2756 40 CEDARVIEW DR PORT TOWNSEND WA 98368-2502 9650 SUBDIVISION: Block: Lot: PARCEL NUMBER: 965000316 Section: 27 Township: 30 N Range: 1V\ CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 REPRESENTATIVE: PHONE: PROJECT DESCRIPTIOP NEW MECHANICAL PERMIT INSTALL HEAT PUMP AND AIR HANDLER TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC MAIN: VALUATION ADD'L: HEAT TYPE: HTP CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: Exist: Prop: Prop: Total: Total: Routing Date: Type Amount Paid By: Date: Receipt: Approved/Date Permit $152.00 SRE 03/06/15 154142 APPROVED Permit $0.00 SRE 03/06/15 Total: $152.00 MAR 0 6 2015 Jefferson County DCD \\tidemark\data\forms\F_BLD_App_Bld.rpt 3/6/2015 i • SON O DEPARTMENT OF COMMUNITY DEVELOPMENT 621 S er d3 c Sir( € P'11; c t zi rtd \k'.��98 68 T i 36(;.3-9,4451 , 4).4451 .Ti tit_I deL 1o, _eltC S9"SI/f .',6\- I ECHAN[CAL PERMIT APPLICATION Steps in the Permit Process: -Review required submittal items to ensure all information is completed prior to submitting application. -Mechanical Permits can be mailed into our office-and do not require an appointment. -Fees are due at time of submittal, Mechanical permits are generally issued within 5 business days. For Department Use Only Receipt#: S4 I y Date: 3/ ,/ Related Application#s: Payment#:, 4 (a c1 (' - Is this application for use in a Mobile/Manufactured Home? * If Yes: A permit from Washington State Department of Labor and Industries, not Jefferson County, is required for appliances installed within a mobile/manufactured home. L&I -360-417-2702 * If No: Complete this form and make an appointment to submit to Jefferson County Permit Tech 360-379-4450 Required Submittal Items-for propane tank only General Site plan —showing propane tank, lines, and distance from tank to all existing structures. Required Submittal Items—for Solar Panel installation only _ Complete first page and signature block only of Mechanical Permit Application. A complete solar panel supplemental application. Site Information Assessor Tax Parcel Number: et 1f1 000"3 ► (y Site Address and/or Directions to Property: L C V . p0(r1-0 W el0.,14 a , I ei it Access (name of street(s) from which access will be gained: 4 0 O tarvitw b 3/4(, Description of Work: 1 1/42tA Li, 4 tat PVrviP c, P 1 Property Owner Name: + o� r Address: _ ,/ _I a Phone#: E-mail Address: — — Please contact Authorized Agent/Representative with project info. Property Owner Signature: Date: Applicant Contractor:/ ntractor: Authorized Agent/Representative Name: I 91:t 1 A 'A 6+00 Q Phone#: 1 E Q E-mail Address: (h License #: A 112.421 l.Quv 00 Expiration Date: J Mechanical Application 1 • • Heat Source Electric V Heating Oil Propane* Wood Indicate Quantity and Fixture Types Below *Propane is prohibited in Quantity Fixture Type Description hazardous locations such as Fan Bath Fan and/or Exhaust Fan basements or pits or Clothes Dryer Clothes Dryer with Exhaust Vent anywhere "heavier-than-air" Cook Stove Cook Stove, Range Hood Exhaust gas can unsafely collect. Fireplace-Gas Fireplace-Gas or Gas Log Insert *Propane tanks over 125 Fireplace-Wood Fireplace-wood, Wood Stove, or gallons require a minimum Pellet Stove setback of 10 ft. from Electric Furnace Electric Furnace or HP+/-Ducting property line and buildings, i and a site plan must be Propane (LP)Gas Furnace Propane Furnace+/- Ducting submitted with the Water Heater-Gas Gas WH Vent and Combustion Air application showing the Gas Pipe System Gas Pipe System LPG/Oil setbacks. If propane tank is Propane Tank LP Fuel Tank(#gallons: ) over 500 gallons, a site plan is Heat Pump required to accompany this Generator application, and a separate Air Conditioner Fire Code approval is also required. Installation manual must be on site at time of inspection or a re-inspection fee will be charged. By signing this application form, the owner/agent attests that the information provided herein, and in any attachments, is true and correct to the best of his, her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in making any issued permit null and void. I further agree to that all activities I intend to undertake or complete associated with this permit will be performed in compliance with all applicable federal, state and county laws and regulations and I agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections. Applicant may request notice of the County's intent to enter upon the property for visits related tto this application and subsequent permit issuance. Signature: N � Print Name: ( tit . � Date: -- i c OFFICE USE ONLY Building Permit Fees Mechanical Permit fee(tank swap,woodstove,furnace,etc) $152.00 Propane— Lines, tank, and appliance (add'I $76.00) Project Scanning Fee $19.00 Total Fees* ,. L(' *Additional fees may apply. -U-D 4 TC1 W CW t Mechanical A p lication 2 ?1P OuJe LA� .ca 1 3/2/2015 Parcel Details _if, ' t„ e erson ,..0 u 11 t v.: 0-k- ,s , „ ..,.„, ,,,, „„0,4 ., 4 ,I. .., ,‘ ,...„........::1104 a-w,,,,,,, 1 t.... /'. - , _ V i'n t...,,V z...; i I .0:V ‘.1,,,,,, . . , ,,,,, N . - - - akabasoTools ?daps t �ebc� ��� ,;:.,.i,,,,...,‘„,,,,,,,,� �� ea x � , Parcel Number: 965000316 SEARCH Parcel Number: 965000316 _r t _°_ r Owner Mailing Address: JON WALLACE 40 CEDARVIEW DR PORT TOWNSEND WA98368-2502 Site Address: 40 CEDARVIEW DR PORT TOWNSEND 98368 Section: 27 School District: Port Townsend (50) Qtr Section: NE1/4 Fire Dist: Chimacum (1) Township: 30N Tax Status: Taxable Range: 1W Tax Code: 0111 Planning area: Tri-Area (4) Sewer: Drainage: Bank: View 1: VIEW - Marine View 2: Zoning 1: Zoning 2: Zoning 3: Sub Division: 9650 - KALA POINT 3-8 Assessor's Land Use Code: 1100 - Residential - Single Unit Property Description: KALA POINT #9 LOT 176 SUBJ/EASE FOR TRACT A Tax, A/ Salmi'Photos, and z per data BIMi\Data °Parcel 4',S€:tiC.•.�t , t�� ���,', :.sly\���: �' \ t"!r ; Jefferson Cunt € �xa HOME I COUNTY E I DEPARTMENTS I SEARCH Best viewed with Microsoft Internet Explorer 6.0 or later Windows - Mac http://www.co.jefferson.wa.us/assessors/parcel/parcel detai I.asp?PAR C EL_N 0=965000316 1/2 3 F $ c..., e zt 0 _ , '.....) $ f I a r \.. N v t g FI O -> r .4„..1 6... .-- ., ,, ,/,/■"w j :: Q p a' n O 0 . ... ,a t Ct.: 14 ... _ %Hu."' a fi no. \ 1 C L, o . iN''C'l rst s't-'..st. ta"q C3`• n aR ,. ■ N.\ '.,, i if, , r, >... ---, , - I • • T.y, x , E Submittal _,,..., Variable Speed ComfortLink' II Heat Pump 4TWV8048A 1000A II -����_� __���, 1111 - ���� TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air- conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. September 2013 4TWV8048A-SUB-1 (i Ingersoll Rand • • fTRANS B ,■/.■----*1!111111.16.. ..-,.. I'l 4.1 4ilip,.. ,,F'\ ,/ .0',m° _ °�:���, SERVICE PANEL C _ %WI FIG.2 COMPONENTCLEARANCESAM ,''` ,,. .y ,,4 �i\ PER PREVAILING CODES ` � � i� <��...4 \I II,All ���``�`���� /* 1 LIQUID LINE SERVICE , . ' � I Ia1l VALVE,"E"I.D.FEMALE `/\ i.,/` H �` BRAZED CONNECTION I- ` ' �� \' WITH 1/4"SAE FLARE F ,,1IIr�l PRESSURE TAP FITTING iu 1 m• GAS LINE SERVICE VALVE, TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 15 FEET) �,�'^�, "D"I.D.FEMALE BRAZED ABOVE UNIT.UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR 'CONNECTION WITH 1/4"SAE FLARE DIRECTLY ON UNIT,AND SHOULD BEAT LEAST 305(12")FROM WALL AND ALL PRESSURE TAP FITTING SURROUNDING SHRUBBERY ONTWO SIDES.OTHERTWO SIDES UNRESTRICTED J L _t-- - ---- G f From Dwg.D156010 FIG.1 I11ii1t miii III 71• ELECTRICAL SERVICE 41, PANEL K I{'11 25 II) III A '�� 1 22.2(LO)DIA.HOLE I LOW VOLTAGE I 101 28.611-1/81 DIA.K.O.WITH 22.2(7/8)DIA.HOLE IN CONTROL ��,� BOX BOTTOM FOR ELECTRICAL Ea' POWER SUPPLY H r 11�'; AluIuIiiM.■ laiI J ' K.O.FOR ALTERNATE G ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, "E"I.D.FEMALE BRAZE GAS LINE 1/4TURN BALL SERVICE VALVE,"D" CONNECTION WITH 1/4"SAE I.D.FEMALE BRAZED CONNECTION WITH 1/4"SAE FLARE PRESSURETAP FITTINGS FLARE PRESSURE TAP FITTING Model Base A B C D E F G H 3 K 4TWV8048A 4 1045 946 870 22-7/8 10-3/8 127 76 197 57 813 (41-1/8) (37-1/4) (34-1/4) (5) (3) (7-3/4) (2-1/4) (32) SOUND POWER LEVEL Model Mode Speed A-Weighted Sound Full Octave Sound Power[dB] Power Level[dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz Cool Min 61 70.6 55.0 55.9 55.8 59.0 49.9 41.1 42.9 4TWV8048A Cool Max 74 75.7 71.9 73.0 74.2 68.5 63.4 59.1 54.3 Heat Min 62 72.1 59.3 58.7 60.3 58.6 51.3 46.0 45.2 Heat Max 76 77.9 74.5 77.0 75.4 69.5 64.4 60.8 56.2 Note:Rated in accordance with AHRI Standard 270-2008 2 4TWV8048A-SUB-1 n. 1 CERTIFIED,. � www.ahridirectory.org C ��� tf$ Unitary Small HP AHRI Standard 210/240 �,sreo CerllficaI aGPlies oly when the complete system h�ea„m�aa Intertek NE Trane optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand,the leader in creating and sustaining safe,comfortable and energy efficient environments,Trane offers a broad portfolio of advanced controls and HVAC systems,comprehensive building services,and parts. For more information,visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2013 Trane 4TWV8048A-SUB-1 13 Sep 2013 00/Ingersoll Rand Supersedes(Newl • • TR/WE" OUTDOOR UNIT(a)(h) 4TWV8048A1000A Mechanical Specification Options POWER CONNS.—V/PH/HZ(H) 208/230/1/60 General MIN.BRCH.CIR.AMPACITY 28.0 The Outdoor Units are charged from the factory for BR.CIR.PROT.RTG.—MAX.(AMPS) 40 matched indoor section and up to 15 feet of piping. COMPRESSOR SCROLL This unit is designed to operate at outdoor ambient NO.USED—NO.SPEEDS 1-VARIABLE temperatures from 55°F to 120°F in cooling and from —10° Fto 66°Fin heating.Only AHRI approved indoor R.L.AMPS(d)—L.R.AMPS 20.3—12.0 matches are approved for use with these models. FACTORY INSTALLED ComfortLinkT' ll START COMPONENTS(e) NA This outdoor unit contains the ComfortLink M II digital INSULATION/SOUND BLANKET YES communication with 2 wire connection to outdoor and COMPRESSOR HEAT YES Plug-n-Play set up. OUTDOORFAN Casing DIA.(IN.)—NO.USED 27.5—1 Unit casing is constructed of heavy gauge.G60 TYPE DRIVE—NO.SPEEDS DIRECT—VARIABLE galvanized steel and painted with a weather-resistant CFM @ 0.0 IN.W.G.(f) 4467 powder paint on all louvers,panels,prepaint on all other panels.Corrosion and weatherproof CMBP-G30 NO.MOTORS—HP 1—1/3 DuraTuffTu base. MOTOR SPEED R.P.M. 200—1200 Refrigerant Controls VOLTS/PH/HZ 208/230/1/60 Refrigeration system controls include condenser fan, F.L.AMPS 2.8 compressor contactor and high and low pressure OUTDOOR COIL TYPE SPINE FIN'" switches.A factory supplied,field installed filter is ROWS—F.P.I. 1 24 standard. FACE AREA(SQ.FT.) 27.87 Compressor TUBE SIZE(IN.) 3/8 Inverter driven scroll compressor with 25 to 100% REFRIGERANT 8410—A output capacity on heat pumps and 30 to 100%output capacity on air conditioners. Noise enclosure LBS.—R-410A(O.D.UNIT)(e) 91b-13oz — minimizes sound levels and built in compressor FACTORY SUPPLIED YES protection protects compressor will reduce operating LINE SIZE—IN.O.D.GAS(n) 7/8 speed and current draw to maintain operation while LINE SIZE—IN.O.D.LIQ.(h) 3/8 protecting the compressor. CHARGING SPECIFICATIONS Condenser Coil SUBCOOLING 10° The Spine Fin TM outdoor coil provides low airflow resistance and efficient heat transfer.The coil is DIMENSIONS H X W X D protected on all four sides by louvered panels. CRATED(IN.) 46.4 x 35.1 x 38.7 Low Ambient Cooling WEIGHT As manufactured,this system has built in freeze SHIPPING(LBS.) 259 protection that will allow cooling operation below 55°F NET(LBS.) 234 but will reduce capacity or shut down completely to H) Certified in accordance with the Air-Source Unitary Air-conditioner prevent operation under adverse conditions. Equipment certification program,which is based on AHRI standard Comfort Control 210/240. (') Rated in accordance with AHRI standard 270. The 950/850 Control is required and provides Plug-n- (0) Calculated in accordance with Natl.Elec.Codes.Use only HACR Play setup and 3 wire connection. circuit breakers or fuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit selection current. (e) NA means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. (f) Standard Air—Dry Coil—Outdoor (g) This value approximate.For more precise value see unit nameplate. (h) Max.linear length 150 ft.;Max.lift—Suction 50 ft.;Max.lift—Liquid 50 ft. 4TWV8048A-SUB-1 3 . • This combination qualifies for a Federal Energy .. % CERTIFIED® Efficiency Tax Credit when placed in service between Feb 17, 2009 and Dec 31, 2013. www.ahridlrectory.org Ceilificate of Product Ratings '. " ':Y�.;s„tF.n. ia.. >.;rF yiz.Sl. AHRI Certified Reference Number: 6750235 Date: 3/2/2015 i Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWV8048A1 Indoor Unit Model Number: *AM8C0C48V41 Manufacturer: TRANE Trade/Brand name: TRANE Series name: XV18I Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: Cooling 'rapacity(Btuh): 47000 EER Rating (Cooling): 12.50 SEER Rating (Cooling): 18.00 Heating Capacity(Btuh)@ 47 F: 41000 I Region IV HSPF Rating (Heating): 10.00 Heating Capacity(Btuh)@ 17 F: 34400* *Ratings followed by an asterisk(*)indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involunta rY rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the f unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and A confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING. CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link µ..Inake fife better' and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. 130697968176368354 ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: tinv • • ed/(4 a/ Po . 02/ ,,71 have„, I tour& -4P/12, 2/5