HomeMy WebLinkAboutBLD2015-00219 - MECHANICAL • MECHANICAL AND DEMOLITION PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD15-00219 Received Date 6/30/2015 SITE ADDRESS: 620 CEDAR AVE Issue Date 6/30/2015 PORT HADLOCK, 98339 APPLICANT: JEFFERSON CO RURAL LIBRY DIST PHONE: 620 CEDAR AVE PORT HADLOCK WA 98339-9514 T 160 SUBDIVISION: Block: Lot: PARCEL NUMBER: 901023018 Section: 2 Township: 29N Range: 1W CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 OWNER, JEFFERSON CO RURAL LIBRY DIST PHONE: if different: 620 CEDAR AVE PORT HADLOCK WA 98339-9514 PROJECT DESCRIPTION: NEW MECHANICAL PERMIT INSTALL HEAT PUMP AND AIR HANDLER Directions To Site: THIS PERMIT IS VALID FOR ONE YEAR AND IS NOT RENEWABLE. THE FINAL INSPECTION MUST BE SCHEDULED AND PASSED WITHIN THAT YEAR. THE EXPIRATION DATE IS 6/30/2016. REQUIRED INSPECTIONS: Installation per Manufacturer Specifications/CO2: Tank/Line/Appliance: Final Approval: 1/5/5-512, BUILDING INSPECTION HOT-LINE 379-4455. REQUESTS MUST BE RECEIVED BY 3 PM THE DAY BEFORE THE INSPECTION IS NEEDED. Office Hours 9:00 a.m. -4:30 p.m. Monday-Thursday HOT LINE AVAILABLE 24 HOURS A DAY 11 tidemark\data\forms\F_BLD_Permit_Propane.rpt 6/30/2015 B• UILDING PERMIT APPLICA•N BRLD1e 0022119 Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT #: BLD15-00219 Received Date: 6/30/2015 SITE ADDRESS: 620 CEDAR AVE PORT HADLOCK, 98339 OWNER: JEFFERSON CO RURAL LIBRY DIST PHONE: 620 CEDAR AVE PORT HADLOCK WA 98339-9514 SUBDIVISION: Block: Lot: T 160 PARCEL NUMBER: 901023018 Section: 2 Township: 29 N Range: 1V1 CONTRACTOR: AIR FLO HEATING COMPANY INC PHONE: 360-683-3901 221 W CEDAR SEQUIM WA 98382 Contractor's License AIRFLI*206DG Expires 4/25/2016 REPRESENTATIVE: PHONE: PROJECT DESCRIPTION NEW MECHANICAL PERMIT INSTALL HEAT PUMP AND AIR HANDLER TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC MAIN: VALUATION ADD'L: HEAT TYPE: HTP CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: # OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: SETBACK: DECK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: Exist: Prop: Prop: Total: Total: Routing Date: Type Amount Paid By: Date: Receipt: Approved/Date Permit $156.00 SRE 06/29/15 156269 Total: $156.00 APPROVED JUN 302015 Jefferson County DCD 1\Tiricmnr41r1nfn1fnrmcl F RI fl Ann Rlrl rnf grInnmis i �,- (V i•, DEPARTMENT OF COM ET `"""" NELOPMENT `'S iING\- ME( 4 Steps in the Permit Process: / / �-Review required submittal items to er n 0,161 /'' G g application. -Mechanical Permits can be mailed int( -Fees are due at time of submittal, Mec ss days. For Department Use Only Date: Related Application#s: 061 1 a -- - r - 1 nent#: Is this application for use in a Mobile, Cosh-aC4 I .+o.vh * If Yes: A permit from Washington Person County,is required for appliances installed w _. iiume. L&I -360-417-2702 * If No: Complete this form and mak. nii appointment to submit to Jefferson County Permit Tech 360-379-4450 Required Submittal Items-for propane tank only LGeneral Site plan —showing propane tank, lines, and distance from tank to all existing structures. Required Submittal Items-for Solar Panel installation only EComplete first page and signature block only of Mechanical Permit Application. _ A complete solar panel supplemental application. Site Information Assessor Tax Parcel Number: C U 4 0,9- 0 I (6 Site Address and/or Directions to Property:to 210 0,17,14 ax- pvc, .. Po r- i-tovi lay Access (name of street(s) from which access will be gained: �V Description of Work: Q Kr, 14 au- PUMtO 4 A(g Ua 1i t- I,i 4 h tLt viol 1'. LA 117., Property O ner ; Name: SG�� _ i, fa _ o Q• Address: tQ O C aX Ave, ca Phone #: ->t-3C) 19C L4 E-mail Address: m x K Applicant/Contractor: Authorized Agent/Representative Name: f'14 ' Y 6- - 1 /6-3ra(Jl a p ati GLo ., Phone#: a /! , °WM" E-mail Address: 44 k4A/11A .eiOW License#: Ai It g-ag DLA Expiration Date: 4( 9-0 1 lP Mechanical Application 1 t • #1111111 ud CERTIFIED www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number: 7420227 Date: 6/23/2015 (� I Product: Split System: Heat Pump with Remote Outdoor Unit-Air-Source Outdoor Unit Model Number: 4TWR4060D1 Indoor Unit Model Number: *AM7B0C60H51 Manufacturer: TRANE Trade/Brand name: TRANE Series name: XR14 Manufacturer responsible for the rating of this system combination is TRANE Rated as follows in accordance with AHRI Standard 210/240-2008 for Unitary Air-Conditioning and Air-Source Heat Pump Equipment and subject to verification of rating accuracy by AHRI-sponsored, independent, third party testing: 0 Cooling Capacity(Btuh): 56500 EER Rating(Cooling): 12.00 SEER Rating (Cooling): 14.50 Heating Capacity(Btuh) @ 47 F: 56000 Region IV HSPF Rating (Heating): 8.50 Heating Capacity(Btuh) @ 17 F: 35400 Ratings followed by an asterisk(')indicate a voluntary rerate of previously published data,unless accompanied with a WAS,which indicates an involuntary rerate. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahrldlrectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and 4 confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; , entered Into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR•CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE • The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate'link ,7 , and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right -- ©2014 Air-Conditioning,Heating,and Refrigeration Institute CERTIFICATE NO.: 130795476148728031 0 rimNE, • 4TWR4060D-SU B-1 TAG: SUBMITTAL NOTE:All dimensions are in mm/inches. 5 Ton Split System B Heat Pum p — 1 Phase �' 4TWR4060D i�'i;'�. ;.``�`� Product Specifications li., .:., ��.`�,�5� (jJ✓`,' a�� >t�\. OUTDOOR UNIT'.;'. 4TWR4060D1000A ;.�f�/%lA�i °i,,.s..•w l>el�r;t .r POWER CONNS.—V/PH/HZ® 208/230/1/60 c MIN.BRCH.CIR.AMPACITY 34 SERVICE PINEL - "�,1jBR.CIR.PROT.RTG.—MAX.(AMPS) 60 ELECTRICAL AID REFRIGERAN , . .+ /s 3'Ij., COMPRESSOR CLIMATUFF®-SCROLL CORPONENL CLEARANCES . 7�! PER PREVAILING CODES �� .` VOLTS/PH/HZ OOL.R.AMPS 200/230/1/60 26.4 / t,`U'Vie, FACTORY INSTALLED START COMPONENTS® NO TOP DISCHARGE AREA SHOVED BE UNRESTRICTED FOR AT LEAST 1524 15 ECM INSULATION/SOUND BLANKET NO ABOVE UNIT. UNIT SHOULD UL PLACED SO ROOF RUN-OFF RATER D0(5 NOT POUR DIRECTLY ON UNIT,AND SHOULD BE Al LEAST 305 112.1 IRON NALL AND ALL COMPRESSOR HEAT YES SURROUNDING SHRUBBERY ON 180 SIDES. OTHER ITO SIDES UNRLSTRICIEO. OUTDOOR FAN PROPELLER T- DIA.(IN.)-NO.USED 27.6-1 iai.H...r ORNAm■Ilinit IMINI■NI ll• TYPE DRIVE-NO.SPEEDS DIRECT-1 ELECTRICAL SERVICE CFM 0.0 IN.W.G.® 4730 PANEL 111 NO.MOTOR' OTORS-HP 1 - 1/4 MOTOR SPEED R.P.M. 825 K VOLTS/PH/HZ 200/230/1/60 F.L.AMPS 1.30 60. I 25 III 11101,IHt OUTDOOR COIL—TYPE SPINE FINTM' A ROWS-F.P.I. 2-24 FACE AREA(SQ.FT) 29.15 TUBE SIZE(IN.) 3/8 22.2 nlel DIA Nat LON NIX TALE REFRIGERANT 26.6 Nrllel DIA. LBS.—R-410A(O.D.UNIT) 13 LBS., 12 OZ. 22 t 11181rpt) IFACTORY SUPPLIED YES II 0 HOLE IN CONTROL ROE BOTTOM FOR ELECTRICAL N F I LINE SIZE-IN.O.D.GAS® 1-1/8 PEER SUPPLY aiii ik m∎miiwin LINE SIZE-IN.O.D.LIQ.® 3/8 (.0 rat AL rEaxuEtLEtrR¢u ROUTING CHARGING SPECIFICATION J AS LINE UA TURN BALL SERVICE VALVE. '0' 10°F LIQUID LINE SERVICE VALVE. I.0 FINALS BRAZED CONNECT LEA YITN 114' SAT SUBCOOLING CONVECTION WITH BRAZE SAE C FLARE PRESSOR[ NAP FITTING H X W X D FLARE PRESSURE TAP FITTINGS. DIMENSIONS CRATED(IN.) 51 x 35.1 x 38.7 r WEIGHT 332 � SHIPPING(LBS.) H 0R� LIQUID LINE SERVICE NET(LBS.) 295 F �Ilil VALVE. 'E D. FEMALE u-.E--- WITHER I SAE FLARE IIMIMI PRESSURE TAP FITTING. AS LINE SERVICE VALVE. •D• I D. FEMALE DRAM 0 Certified in accordance with the Air-Source Unitary Air-conditioner Equipment certification program,which CONNECTION Ti In 111' is based on AHRI standard 210/240. J F- FIT rING.RASE PRESSURE TAP OO Rated in accordance with AHRI standard 270. F rt 0 Calculated In accordance with Nall.eec.Cedes.Use only HACR circuit breakers or fuses. G 0 Standard Air—Dry Coil—Outdoor E1.0._1 © This value approximate.For more precise value see unit nameplate. Cif N Max,linear length 60 ft.;Max,lift-Suction 60 ft.;Max lift-Liquid 60 ft. For greater length consult refrigerant piping software Pub.No 32-3312-0' ('denotes latest revision). MODELS BASE A I C D E F O H J K c') This value shown for compressor RLA on the unt nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max.f use size.The value shown is the branch circuit selection Ira? 946 870 98 2E9 e6 current. 4Tw940000 4 140 tree (a7 314) 174-Val 1-5/a 3121 152(61 ,3 7rel (8-5/61 ,3-:Ae.. sou(DOi ) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. Sound Power Level A-Weighted Full Octave Sound Power[dB] Model Sound Power Level [dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR4060D 76 71 71 76 76 74 69 62 55 Note:Rated in accordance with AHRI Standard 270-2008 ©2014 Trane Mechanical Specification Options General Condenser Coil The 4TWR4 is fully charged from the The outdoor coil provides low airflow factory for up to 15 feet of piping.This resistance and efficient heat transfer. unit is designed to operate at outdoor The coil is protected on all four sides by ambient temperatures as high as 115°F. louvered panels. Cooling capacities are matched with Low Ambient Cooling a wide selection of air handlers and As manufactured,this unit has a cooling furnace coils that are AHRI certified.The capability to 55°F.The addition of an unit is certified to UL 1995.Exterior is evaporator defrost control with TXV designed for outdoor application. permits low ambient cooling to 20° F. Casing Accessories Unit casing is constructed of heavy Thermostats—Cooling only and gauge, G90 galvanized steel and heat/cooling(manual and automatic painted with a weather-resistant powder changeover).Sub-base to match paint on fan top cover and louvered thermostat and locking thermostat cover. panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection and total dipped hermetic motor.Other features include:centrifugal oil pump and low vibration and noise. ti PI CERTIFIED m C ous www.a hridireclory.mg Unitary Smail HP AHRI Standard 210/240 sre CeliYw1�IMPPPPP aJr•hen Ph oarq=,e rys em Intertek TRANS 07/14 Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. • • Submittal X/ 5 Ton Convertible Air Handler TAM7B0C60H51SC— Standard Coil TAM7B0C60H51 EA— Black Epoxy Coil 40°^"iii. 111041.. . _ 1 ,0 1 iE 41 r 10 TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. February 2015 TAM7A0C60-SU B-1 H-EN (IR)ingersoll Rand • • Outline Drawing 21 60 1.50 d IN.35 5.95 MINIMUM UNIT CLEARANCE TABLE 1.5D TO SERVICE -R� COMBUSTIBLE SERVICE NATERLAL RECOMMENDED) IREOUIRED) SIDES D' 2'FRONT RACK 0' D' D E `__ ® INLET DUCT 0' Q OUTLET DUCT 0' L sD t GAS LINE F 3.00 LIQUID LINE SEE TABLE ' 0 3/8 . BEIER J I1!M_r: g A I B .. ( 1 ii tJ • J Pl G 1.50 21.80 El H l7 O r7 1 j 1.50 17.15 3.15 1.501 117777 , Cr q =======— I1 r a I■mow LE■ , I 50 J-- MODEL NO. A B C D E F H FLOW GAS LINE LIQ LINE CONTROL BRAZE BRAZE TAM780C60H515C 61.7 51.5 20.5 23.5 20.5 10.3 24.9 EEV 7/8 3/8 TAM7B0C60H51EA 2 TAM7A0C60-SUB-1 H-EN 0 PRODUCT SPECIFICATIONS MODEL TAM7BOC6051SC . _ TAM7BOC6051EA RATED VOLTS/PH/HZ. 200-230/1/60 RATINGS(a) See O.D.Specifications INDOOR COIL-Type Plate Fin Rows-F.P.I. 4-14 I Face Area(sq.ft.) 5.96 Tube Size(in.) 3/8 Refrigerant Control EEV Drain Conn.Size(in.)(b) 3/4 NPT DUCT CONNECTIONS See Outline Drawing INDOOR FAN-Type Centrifugal Diameter-Width(In.) 11 x 10 No.Used 1 Drive-No.Speeds Direct-Variable CFM vs.In.w.g. See Fan Performance Table No.Motors-H.P. 1-1 Motor Speed RPM Variable ECM Volts/Ph/Hz 208-230/1/60 F.L.Amps 5.5 FILTER Filter Furnished? No Type Recommended Throwaway No.-Size-Thickness 1-22 x 20-1 in. REFRIGERANT R-410A Ref.Line Connections Brazed Coupling or Conn.Size-in.Gas 7/8 Coupling or Conn.Size-in.Liq. 3/8 DIMENSIONS H x W x D Crated(In.) 62-3/4 x 25-1/4 x 23-1/2 Uncrated 61-11/16 x 23-1/2 x 21-3/4 WEIGHT Shipping(Lbs.)/Net(Lbs.) 175/163 (a) These Air Handlers are AHRI certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240). (D) 3/4"Male Plastic Pipe(Ref.:ASTM 1785-76) TAM7BOC6OH51SC,TAM7BOC6OH51EA 240 Volt. 208 Volt Heater Model No. No.of Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Circuits kW BTUH Amps per Circuit Overload kW BTUH Amps per Circuit Overload Circuit Ampacity Protection Circuit Ampacity Protection No Heater 0 - - 5.5** 7 15 - - 5.5** 5 15 BAYEVAC04++1 1 3.84 13100 16.0 27 30 2.88 9800 13.8 24 25 BAYEVAC05++1 1 4.80 16400 20.0 32 35 3.60 12300 17.3 29 30 BAYEVAC08++1 1 7.68 26200 32.0 47 50 5.76 19700 27.7 41 45 BAYEVAC10++1 1 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAYEVAC10LG3 1-3 PH 9.60 32800 23.1 35 35 7.20 24600 20.0 31 35 BAYEVBC15LG3 1-3 PH 14.40 42000 34.6 49 50 10.80 36900 30.0 44 45 BAYEVBC15BK1-Circuit 1(3) 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAYEVBC15BK1-Circuit 2 _ 2 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 BAYEVBC20BK1-Circuit 1 2 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 BAYEVBC20BK1-Circuit 2 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYEVCC2SBK1(H-Circuit 1 9.60 32800 40.0 57 60 7.20 24600 34.6 50 50 (a)BAYEVCC25BK1-Circuit 2 3 9.60 32800 40.0 50 50 7.20 24600 34.6 43 45 BAYEVCC25BK1-Circuit 3 4.80 16400 20.0 25 25 3.60 12300 17.3 22 25 1. **Motor Amps 2. See Air Handler nameplate for additional information. 3. Heater model numbers may have additional suffix digits. (a) MCA and MOP for circuit 1 contains the motor amps to Heater not qualified for 208V when installed in horizontal left position without Heat Pump. TAM7AOC60-SUB-1 H-EN 3 al • 0 0 .-1 O II- 1- M H N M Cr‘,,,, h N tp C"'.y h.0 No., h In M O 0 W PI= M O - C N 0 O P, N D 'i O al W N h .I O M 0 C Y - a ,�T V W N 0 L'1 `i �D W �D O I� I� r CC O CO M O,N O�M O W n N .-I m to 0 J .-I C C -y C -1 Ln .-,N .1 M 1-i b -1 t0 'y!� ,_y h r-I�� .- RI N SJ N Gl N 01 3 LA 3 es N w 0 7, U N 0) Y a h N i IA..t O 00 N 111, N 0, W ti N M N. �D c , W O O M O 10 = 6 W in N -I Ill OJ •.'1 O M h c0 co h N CO C 0) G� C Y N to rn o N v rn -y -1 n In .y a °' v, in o , O Ci-0 7C .CiC .-fC OC ,_Ln D W aLA ,0 ,10 GC.--• mh h ONw^ ON = NO i m a W C V C a u U a h Ln h Ol I M r N U o J O m ` RI U]O 1"--- 10 O o 0 O N 0 A .-1 N h D Cr W al CC t0 00 h N 0 x o f W J K M 0 0 M al h O 0 O N } "'�71 h W O 7 0 h h ON M 0 N 0N Ili h O N C M 0 M LL Q 01 U W O C C N C IA M M 0M h C O ,ti M IO O,..0 O h U y N a M 'y M - -y N ,y C N ,y C . O N r` N 1:13 C co W X O 0 W 0 N Z C h h O M Ni 0 LA G1 .-i C 00 M C tD O O N '' Y i.I 1.4 .-1 O Q M W O M O 3 co N 0 0 h 0 N,:0, `-1 .-1 0 Q- co W 0 Itl •ti V O In N O -c al • 4' CO I1) C Q C C in- M tD .0 rn t0 h 0 co ti M rh N.D Ul`� O N O .-`C > E O CO ry W O c N c N n. .-1~ N •y M r c M... c M .d C `� c C c N N trl N L'1 N tp O.0 C C ti b N M 3 m U _ U \ vl C 0 3 c o > o .c C_p Y Y w Ill Ctn m .0, a �n to rn iN. In 0, 0 to 0, n 3�_ C p > .N-I N F � 3 La I LL f L ti lc al LL 0 L 0 L m LL I � %n LL In LI- ti U � LL In LL In LL OJ LL �o °< 0 =+ CO z Lco U U� U ? UUU U3U3 '-J5UU > USUSU$ U U Cf p Q n W Y 3 w C F a v U _ 2 k i- v (/1 o J 10 N M Z a oo •l v It C7 M n. E 0 l7 0 c C C C c C c "' c C C- C C C C C ry 7 ~ N ID w U Z O Z O `O O O, O a0• O.- O' O O O 0 i O O O O O ac.� -O N f0 Q "1 - l Ca \ FLL o� *+� NAM£ ° F E vz ci rti Y2 N2 Mg°E 'er2 NL rri `ww � U N Z m O W C' C L_ C E C C u_ C L_ C t>. E W W C , C 0_ C y.C LL V 0_ ' W 4 T u o 3 W > in C N ill Gl=arn U U U U U U U U U U U U U U U U c E0 H } NI -0 S. Lo ._ Q a CO c�co 5 MO hU1 -, O Nto VD 0 O01 C0 0J 0 IA In 0+-( C 0001 tO us00 el CO 0 C -N N- 1",,' O I CO Q m LLrJ 0 O 0 N ti N N N M CO r,, C M M C t0 L1 O1 li).� 111 C tO to N"'I .hi N CO 0)= C) I 0 N N i-i N _ M .-1 M .4 M ^1 M .- 'S .-i d' .'I C ••• ..•-1 us .-1 0 .--■111 e-1 0 0 l0 L .0 o I cc T es 0 o N N"t'.--- -_N.-,V'N- \N'N N\N N \\N N N.N.N.N\N--N'N � = co 10 t:N \ M CJ t0 M co a O M C 0 co LU o CO.. N In a h LU co IL)•'1 N O 0l C n-I IL/1 Q o - 0 co a .0 Z ~ O O M.N ■ M O in h ■ .-1 N C C 00 4 C!1 CO C en h h O N C 0. 0) N M IN CO w -I co LLJ L M C M'C M C C C d• C C7 U) In u) U)Ii) t0 LD t0 to 10 tD h h CO h co h as W 01 W U O Q c .y .■ .-1 1-I 1- .+ " .. -1 .-1 .-1 .I .-I • . . .-1 .+ w U I- U .0 (.0 0 t0 no O us h SD O 'n O CO 0 LIl 0 CO N 3.0 O 0 < 0 Z • C O Mt O N C W 0 U)N 03 O M O h 0 C C C O N t0 h CO N CO N-C) M- to N D > W o h O N N M M W C O C N In IA N CC tO O lO M h 10 N O 00 C 0O 0) C J W 0 C L 0 h .o N .-%N .-1 M .■M - M c M C •J' .-t C .-1 C lC1 ■y LI} .y in .-1 to .-1 t0 .ti tp N E Q .On _ N • NNNNN_---NN`-,N N.N.N N.N.\ N-N N N\\N,\\\N N.N.\'N\ E = Ly co E 0 O C N 0 M t0 LA N .0 N N C.0.D U1 01 0 Dl h 01 O O M c-l N N N M M IN ill C 1~.1 L 0. U In M M M M M C C C C In a Ln 1- ill Ln D 1) tO Ic-I N W N'0 L0 r9 C CC GO IN 0)N C i co O O (r 3 10 0 W Y ,•••• .y .i .r --I - .-■ .-t 1-1 -I .y .I .d 1C1 - 2 Z .-1 .1 \ C C U C +C O N .D .t 0 �0 C uO 01 M h N O 0 m 10 '" m J 0 E 'C C to m Z in C 0 r M C) h C 0 C N IN 0 -i 0 Ln CT. •+ M Ui 00 0 C C N.0)U) C CO 0 0 0)0 3 H 0 0 N L Q C N tO N N .Mi CO M O C C C tO LO h to 0 tO M tD to IN W N .-1.IN Cr 1b IL) 0 .-i Ch to u - Q .�.� C 4 .* _ £ O In -'1N N,N IN tiM 1 M -1 M M C .i C .--1 C .-1 IA .1-1 LA 1.-1 LA .-1 t0 Nt0 a W U U \ F v j U N NN\N NNN .-..N N \\NN\NN O N 0 N N C N N-, N;N u o = a s a -C O �. O CO 7I- CT PI 0 C N ..] M W CO CO CO ON OO .+OO C CO kDO In Ch 'n O co () ! >> < -0 at_+ 0 1-1 N •-1 N N 0` C N l0 Cr, 00 N C Li C O 0 L0 C O N 0 IA co 0 M co co tD "1 .- OO 0 T L W W N U. 10 M al M M M cc C M 0 M Lr)C Li C' 0 d' tC Il` h t(1 hi In N Ln CO 0 CO 0 a h 0 h U m = >->- .~i = d 3 W r 0 04 C t0 t0 N O) N 1t` h 0 M N IN M al E E N (] t. Y a L0J M C 0 h O) O N In .-1 d to.-1 CO O N 0) CC M N N IN C - .-1'0 N .y 0 0 0O .1 co N X Z = z 7 3 rt.' M M M CO M t0 C h In .-1 U1 M M In t0 CJ 0 O h N IN LA CO W..W•-■ 01 Ln O CC O N J O M .„1 C L. en 0 d M Y N .-1 N a N .-I N •-+ M M ri .-1 M S C .-i sj .-1 C .-1 C r-1 N c U} to N t0 Q G Y(J 0 u • N N\\ N N N-'-\N\N \-,\\ \-_ N\\N N N\--.h.\N N-`.N p o co J O �j ..1 O CO CO O N CD N 0 M N Cr 10 C O 0 1, 0 r) -U O N O) C 01 M N N'.M C C co CG Y re CO W .1 V - IL H N N to N 0 CC N O C M 04 U) 0 h 0 ON Ln M O O C CO CO.9 M N CO 0) M M 00 IN H 0) O . Ct H -rn N .M-I N rI N N M V M .-I M lfl M -co .0 C h C 1- C N Ul OO N I Ln .- V' 0) tD O Ua a \ Ip 0 Q C Vt L.L. O M CO C Cl CO O) .-1 M .d .-1 .-1 to N re >W t0 00 0 O < O.I MM .0 ur 0 M:4 .-■li) NM CO N CL') 00 0 MtO IN CO.N10 INN NO M1..O 07 1/1 UI} 0 10 N {0 Z • HN .4N S N VNN .-N -N OM ,UM DI N-t m r M CO C W C.. .O-1C .�'1Lii NO LA N:Ul o as o O el J V co IlJ 0\\N N-- \N NN NN N--N N 0, \\\\\N\\In\\\in\ V L 'C C F 0 tOC en N. .- O MC IA 0 NI 00 0 Mt0 N O Ct0 tO M 0ON tON1nN Cin NM N J 0 .1 0'I C O CO N C N �p O N OO W O 0)N 0 t0 Cr 0O M h C;..N C 00 0 01 in n 01 L In N w M.+ MN I') N CN C N LAN W M in cc OM 1-i n CC'.WC PO U) 01 Ul ri E N W .i :-i r r-f .4 .-f ■Y .�. .i .i Cl rl YI M L!_ y U - .y(i.-i.i 0 In Q _ Y_I to_1 O m 0~ J I� rn N v Y 1 0 n 0' y N' In ✓: tn VI O V ymj IJII W 't c 9� s z E ,., s ti7 � ,� Ii m � ,o £'0 LL.m mLL � £ 0 OOOO .+ 1� = L rp U rp II 17 W N W I0 W LL N Lc `r L N rp U U IYU UsUSU ? (J U -> U3U � U u ; U3U� U�;u3U U � Ug 0 't QaQaN at > > M 3 Q a v m w w W w m to > l7 3(7 n c c = = C C C c C C C c = W 'ul Y a m m CO Ca o t to o Z 0 Z 0 0 0 0 0 o V + Y 0 0 0 0 0 0 0 ❑ 0 o O'' 0=0 O- 0 O 0 O Y O 0 Y 04-10-la O O 04- _ J.. h co 0 O� h �'0J G)-�O\O\(q N O. O`�T IN NOON0N0'N O)0 = h- U 0-•• M 0 ^'w ` 0_• C 0_ �) I- M W M.•_ C 0_ rho 0_ M LL M u_ C Li. M W 0 M 0 C 0_ C j - 3 j W U a N U U U U U U 'J U U U U U U U U U v u v Ip m m m ❑ o O E 'c ` C W E 1 U K J 0 p J w C C Vf C u 0 2 w ❑ m C C Z i .°.t o c o m 3 L 0 f F J O Ul 7 0 -' + R V) O t°- F a 01 to 4 TAM7A0C60-SUB-1 H-EN • • Features and Benefits • Unique cabinet design • Vortica®blower with polarized plug connections - 2%or less air leakage and integrated slide deck for easy removal • Aluminum coil with integrated slide deck for easy — Precision applied — durable door seals removal and polarized plug connections on coil EEV — Specially designed air seal around refrigerant, • Patented enhanced coil fin condensate and conduit connections • Electronic Expansion Valve(EEV)with low ambient — Double wall foamed cabinet system and low superheat compressor protection • — R-4.2 Insulating Value(Avg Insulating Value R Dual refrigerant compatible as shipped 8.2) • Slide in electric heaters with polarized plug connections(sold as accessory) — No loose fiber design • Slide in hot water coils with polarized plug — Smooth cleanable interior design connections(sold as accessory) — Sweat eliminating design • UVC light kit with safety switch and polarized plug connections(sold as accessory) — Composite foamed cabinet doors • Labeled panels and connections — Water proof cabinet design • Molded in 1" standard filter rail — Integrated horizontal drain pans • Variable speed ECM motor - Modular cabinet • Soft start fan motor operation • Multi-position up/down flow horizontal left/right • Comfort RTM mode • Side return option (sold as accessory) • • Built in fan delay modes • Control board protection pocket built into cabinet Maximum width of 23.5" wall • Compact 20.8" depth with doors removed • • Pre-marked Conduit Connection Locations Fused 24v power • Alert port to view control board codes without door • Safety door switch removal • 5 Year Warranty • Alert code notification • 10 Year Warranty Registered • Low voltage terminal connection point • Optional Extended Warranty Available • Phillips head door fasteners .�+l*I CERTIFIED- 111-111211 sou CERTIFIED. 4irous C www.ahridirectary.arg C www.ahrilli rectory.org Unitary Small AC Unitary Small HP isrc AHRI Standard 210/240 AHRI Standard 210/240 LMfieaIIm ae11eimiy wM1en tK,Omplete synem CINM1GM1m awies erhwnen IDe¢ampere ryaMm Is usad emepp. PS lhled Mm aXAL I ntertek The manufacturer optimizes the performance of homes and buildings around the world. A business of Ingersoll Rand, the leader in creating and sustaining safe, comfortable and energy efficient environments, the manufacturer offers a broad portfolio of advanced controls and HVAC systems, comprehensive building services, and parts. For more information,visit www.IRCO.com. The manufacturer has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. Cs2015 Trane TAM7A0C6o-SUB-1I4-EN 11 Feb2015 ��Ingersoll Rand Supersedes TAM7A0C60-SUB-1G-EN (February 201 4) �; f • rri COPY 9'6 June 16,2015 F��--�L� et-ral pi'? Jefferson County Library 820 Cedar Street Had lock,WA 98339 Attn: Meredith Wagner& Daniel Heaton Re: North 5-ton Trane Heat Pump&Air Handler Replacement This proposal was developed after an onsite inspection and with the clients best interests in mind. • Remove, recycle and recover existing Trane 5-ton R-22 Heat pump and air handler • Provide, design and install new Trane 5-ton system with Variable speed Air Handler. • Hook up existing Honeywell Prestige control. • 1-year labor, 1-year parts and 5-year compressor warranty. • Installation will be completed by July 10th, 2015. Cost: $ 7,035.00 plus sales tax This proposal was based on prevailing wage Proposal valid for 90 days All electrical, equipment, labor, material, permits and disposal included—No Extras. Thank you, Joel R. Berson Accepted: Meredith Wagner / Date: Vd—y/ 3 S i • rop 9'6 fy-A June 16, 2015 vJ efu' j� [rJ � � Jefferson County Library ✓`' 620 Cedar Street Hadlock,WA 98339 Attn: Meredith Wagner& Daniel Heaton Re: North 5-ton Trane Heat Pump&Air Handler Replacement This proposal was developed after an onsite inspection and with the client's best interests in mind. • Remove, recycle and recover existing Trane 5-ton R-22 Heat pump and air handler • Provide, design and install new Trane 5-ton system with Variable speed Air Handler. • Hook up existing Honeywell Prestige control. • 1-year labor, 1-year parts and 5-year compressor warranty. • Installation will be completed by July 10'h, 2015. Cost: $7,035.00 plus sales tax This proposal was based on prevailing wage Proposal valid for 90 days All electrical, equipment, labor, material, permits and disposal included—No Extras. Thank you, • Joel R. Berson Accepted: Meredith Wagner Date: 0-y/ Y %lb) Parcel Details • Page 1 of 2 _ Je County Weather Station .. . Database Too „# 'a y. Maps ., C. Q° Vtelrcam a Home County Info Departments Search Parcel Number: 901023018 I E SEARCH Parcel Number: 901023018 Printer Friendly Owner Mailing Address: JEFFERSON CO RURAL LIBRY DIST 620 CEDAR AVE PORT HADLOCK WA98339-9514 Site Address: Section: 2 School District: Chimacum (49) Qtr Section: SW1/4 Fire Dist: Chimacum (1) Township: 29N Tax Status: COUNTY Range: 1W Tax Code: 0211 Planning area:Tri-Area (4) Sewer: Drainage: Bank: View 1: View 2: Zoning 1: UGA-P - Public Zoning 2: Zoning 3: Sub Division: Assessor's Land---Use_Code: 9700 - Exempt Property Property Description: S2 T29 R1W - RURAL LIBRARY TAX 160(ENGLD BY TAX 188) BND BY BLA#84386 W/PTN VAC RD ADJ Tax, A/V, Sales, Photos, and Permit Data Bldg Data Map Parcel Plats &Surve s $EDtIC Monitoring Info I .le et5 County HOME I COUNTY INFO I DEPARTMENTS I SEARCH Best viewed with Microsoft Internet Explorer 6.0 or later ejWindows- Mac http://www.co.jefferson.wa.us/assessors/parcel/parceldetail.asp?value=901023018 6/30/2015 AIR FLO HEATING COMPANY Page 1 of 2 Home Inicioen Espanol Contact Search L&I j ,-SEARCH A-Z Index Help My Secure L&I Safety Claims&Insurance Workplace Rights Trades&Licensing CiWashington State Department of Labor & Industries AIR FLO HEATING COMPANY INC Owner or tradesperson 221 WEST CEDAR Principals 360-683-3901 WA 98382 360-683-3901 BEQUETTE,MARK A,PRESIDENT CLALLAM County BEQUETTE,SANDRA A,VICE PRESIDENT BERSON,JOEL R,SECRETARY FULLAWAY,MICHAEL (End:04/01/2010) Doing business as AIR FLO HEATING COMPANY INC WA UBI No. Business type 600 347 761 Corporation Governing persons MARK BEQUETTE SANDRA BEQUETTE; License Verify the contractors active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNenVAir-Conditioning and Refrig (HVAC/R) License no. AIRFLI*206DG Effective—expiration 03/07/1980—04/25/2016 Bond CBIC $6,000.00 Bond account no. 515215 Received by L8I Effective date 02/05/2010 02/01/2010 Expiration date Until Canceled Bond history Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no. 44CL483619 Received by L&I Effective date 04/21/2015 04/25/2014 https://secure.lni.wa-gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 6/30/2015 AIR FLU HEATING COMPANY 1 • Page 2 of 2 Expiration date 04/25/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. IWorkers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 351,432-00 Doing business as AIR FLO HEATING COMPANY INC. Estimated workers reported Quarter 1 of Year 2015"21 to 30 Workers" L&I account representative T3/NATASHA DRAGOVICH(360)902-4679-Email:DRAG235 @Ini.wa.gov IWorkplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Citation issue date 07/24/2012 Violations Inspection no. 315954529 • Location 125 Horizon View Dr. Sequim,WA 98382 tD Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 6/30/2015 AIR FLO HEATING COMPANY 11 • Page 2 of 2 Expiration date 04/25/2016 Insurance history Savings No savings accounts during the previous 6 year period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. L&I Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 351,432.00 Doing business as AIR FLO HEATING COMPANY INC. Estimated workers reported Quarter 1 of Year 2015"21 to 30 Workers" L&I account representative T3/NATASHA DRAGOVICH(360)902-4679-Email:DRAG235 @Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Citation issue date 07/24/2012 Violations Inspection no. 315954529 Location 125 Horizon View Dr. Sequim,WA 96382 5 Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. it https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 6/30/2015 AIR FLU HEATING COMPANY • Page 1 of 2 Home Inicio en Rspafiol Contact Search L&I I 5.I.AfiCh A-Z Index Help My Secure L&I Safety Claims&Insurance Workplace Rights Trades&Licensing Washington State Department of kLabor & Industries AIR FLO HEATING COMPANY INC Owner or tradesperson 221 WEST CEDAR SEQUIM,WA 98382 Principals 360-683-3901 BEQUETTE,MARK A,PRESIDENT CLALLAM County BEQUETTE,SANDRA A,VICE PRESIDENT BERSON,JOEL R,SECRETARY FULLAWAY,MICHAEL (End:04/01/2010) Doing business as AIR FLO HEATING COMPANY INC WA UBI No. Business type 600 347 761 Corporation Governing persons MARK BEQUETTE SANDRA BEQUETTE; License Verify the contractors active registration/license/certification(depending on trade)and any past violations. Construction Contractor Active. Meets current requirements. License specialties HeatingNent/Air-Conditioning and Refrig (HVAC/R) License no. AIRFLI*206DG Effective—expiration 03/07/1980-04/25/2016 Bond CBIC $6,000.00 Bond account no. 515215 Received by L&I Effective date 02/05/2010 02/01/2010 Expiration date Until Canceled Bond history Insurance American Hallmark Ins Co of Te $1,000,000.00 Policy no. 44CL483619 Received by L&I Effective date 04/21/2015 04/25/2014 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600347761&LIC=AIRFLI*206DG&SAW= 6/30/2015