BLD2014-00350
',BUILDING PERMIT APPLIC•ON BLD14-00350 Review Type: Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT#: BLD14-00350 Received Date: 9/29/2014 SITE ADDRESS: 63 FOUR CORNERS RD PORT TOWNSEND, 98368 OWNER: JEFFERSON TRANSIT PHONE: 1615WSIMSWAY PORT TOWNSEND WA 98368-3090 SUBDIVISION: Block: Lot: PARCEL NUMBER: 001332009 Section: 33 Township: 30 N Range: 1V1 CONTRACTOR: FIRE CHIEF EQUIPMENT PHONE: 425-522-1226 MARK KUSHINO 7661 159TH PL NE REDMOND WA 98052 Contractor's License FIRECCE938JR Expires 4/19/2015 REPRESENTATIVE: PHONE: PROJECT DESCRIPTIOI NEW NOTIFIER NFW-100 FIRE ALARM SYSTEM TYPE OF WORK COM SQUARE FOOTAGE: COMMERCIAL: TYPE OF IMP MEC MAIN: INDUSTRIAL: VALUATION 15,458.00 ADD'L: HEAT TYPE: CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: SETBACK: DECK: BANK HEIGHT: SEWAGE DISPOSAL: NUMBER OF EMPLOYEES: WATER SYSTEM: BATHROOMS: Exist: Prop: Total: Routing Date: Type Amount Paid By: Date: Receipt: Approved/Date Permit $223.00 JLA 09/29/14 151550 Plan Check $144.95 JLA 09/29/14 151550 APPROVED State Building Code $4.50 JLA 09/29/14 151550 OCT 14 2014 Total: $372.45 Jefferson County DCC \\tidemark\data\forms\F_BLD_App_Bld.rpt 9/29/2014 y WY Y 1Y 4 \ IN MI 1 V Y Jefferson County CONTRACTORS MATERIAL AND TEST CERTIFICATE FIRE ALARM AND FIRE DETECTION SYSTEMS Fire alarm System is ready for Fire Department acceptance testing. Failure of test will result in termination of the testing and additional fees will be assessed. Contractor is responsible for supplying manpower for Final Acceptance Test with two-way communications. Date 7/17/15 Permit# BLD14-00350 Property Address 63 Four Corners Rd Suite# City aftlftweilt/r Port Townsend,WA Zip Code 98368 Name of Facility Jefferson Transit Authority Occupied as same Owner or Representative same Phone# Installing Company Fire Chief Equipment Installing Contractor's Address 7661 159th PINE City Redmond Phone# 425/641-2127 Installer's Name(PRINT) Alan Kutner License and/or Certificate FIRECCE938JR General Contractor N/A Electrical Contractor Olympic Electric OLYMPEDC285D1 FACP Equipment Manufacturer Notifier Model# NEW-100 This system has been installed,pre-tested and operates in accordance with the standards listed below and was inspected by On(date) and includes the devices listed on back. Circle all that apply: X NFPA 72, Chapter 1 2 4 5 6 7 and/or IFC SEC 907 X NFPA 70,National Electrical Code, Article 760 Manufacturer's Instructions Manufacturer's Instructions Other(specify) Tukwila City Ordinance Numbers 2050, 2051 Fire Chief Equipment UL Central Station Monitor 37,7225 System is monitored by (Alarm Center) SIGNED Date System Firmware: Installed version Checksum Date Initial program Installation Date Revisions and Reasons Programmed by Alan Kutner EQUIPMENT INSTALLED TESTED: Control Panel 1 of 1 Make/Model Notifier NFW2-100 Manual Station 9 of 9 Make/Model Notifier NOT-BG12LX Smoke Detectors 3 of 3 Make/Model Notifier NP-100 Heat Detectors _of Make/Model Duct Detectors 4 of 4 Make/Model Notifier D4120 AN Devices 31 of 31 Make/Model Notifier PC2R, P2R&P2RK Audio Devices 1 of 1 Make/Model Notifier MB-G10-24-R Visual Devices 6 of 6 Make/Model Notifier SCR, SR&SRK Auto Door Release of Make/Model Trouble Indictors of Make/Model Batteries Readings Battery 25.1 Full Load 24.8 Charge ok N/A Generator _of Make/Model HVAC Controls of_ Make/Model N/A Fire Alarm Dialer of_ Make/Model DACT built into panel Monitored by FCE - Alarm Center Acct# 37,7225 Annunciator of Make/Model X Sprinkler System. (Fire Alarm connections only) Water Flow Sw. 1 of 1 Make/Model Valve Tamper Sw. 1 of 1 Make/Model PIV - of - Make/Model Elec. Alarm Bell 1 of 1 Make/Model Automatic time Delay of Water Flow Alarm 24 seconds.None Installed Do you meet audible/visible requirements of WAC 51-20,IFC SEC 907., and/or NFPA 72 Chapter 6? Yes x No Test of alarm System o emergency power, satisfactory? Yes X No Test Witnessed b om Title C.9.v •vtrtit4. Date 6/8/15 �N//FlWi/ pin.E.' C vD 6 /Ar.rpEcrG,e Comments: '-!&'f Cd. D G D. Fire Alarm Certificate.doc Revised: 10/28/04 TFD FP Form 4110 PI' CHIEF �� EQUIPMENT 7661 159'' PINE,Redmond WA 98052 P O Box 659,Redmond WA 98073 Telephone No.425-641-2127/Fax No.425-562-6662 Jefferson Transit Authority FCE Job # 14-1300 Table of Contents for Equipment Submittals Item Equipment description 1 NFW-100 Addressable FACP 2 FCPS-24S8 Booster Power Supply 3 Indoor and Outdoor Hom/Strobes (P2R, P2RK & PC2R) 4 NP-100 Photo Smoke Detector 5 FDU-80 Remote Annunciator 6 NOT-BG12LX Pull Station 7 D4120 Conventional Duct Detector 8 N 100-ISO Iso-Isolation Module 9 NMM-100 & NMM-100P Addressable Modules (same data sheet) 10 NC-100R Relay Module DN-60602:A1 FireWarden-100-2(E) Rev 3 (1J N OT I F I E R Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3 (NFW2-100)with Version 5.0 firmware is a combination FACP(Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter)all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled.When construction is completed,the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS,and increased power for the reset- table and remote sync outputs. Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public • Remote site or local USB port upload/download, using PS- switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four(4) Style V (Class B) NAC circuits, which can be con- load utility.In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows®XP or greater, a corn- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software • Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged • ANN-BUS for connection to following optional modules(cannot directly into the printed circuit board.This permits easy typing of be used if ACS annunciators are used): address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec- —N-ANN-80(-W)Remote LCD Annunciator ondary ANN-bus devices,NP-A100,USB port,NAC circuit diag- —N-ANN-I/O LED Driver nostics,a new report has been added to the walk-test that lists —N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone —N-ANN-RLY Relay Module type code for NFV-25/50ZST,Photo Supervisory and auto-reset- —N-ANN-LED Annunciator Module table Drill(non-latching). —N-ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 —ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the ACS&Terminal-mode Annunciators: •Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone —ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term "FireWarden-100-2" —Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWarden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-100E as welt cult board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point • Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E:Same as NFW2-100,except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NACS): lion. • Four onboard NACs with additional NAC capability using out- 4XTM Reverse Polarity Transmitter Module: Provides super- put control modules (NC-100). The four Class B NACs can aned output for local energy municipal box transmitter, alarm, be converted to four Class A NACs with optional ZNAC-92 and trouble. converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y(Class B) NAC circuits to four(4) Style Z (Class A)cir- cuits. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. PS Tools: Programming software for Windows®-based PC Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. •• 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE: Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-248 transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram (learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than Continuous fire protection during online programming at the 18AH. • front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable;required for printer or for local upload/download program- able on www.magni-fire.com).Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT-2/2UD,IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). User Interface Connects to primary and secondary DACT telephone output ports for internet communications over customer provided ether- net INDICATORS net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IP.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6-DN-60602:A1•12/07/2010 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-100R: Addressable relay module containing two isolated N-ANN-RLED: Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box,surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT-BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connection for a serial or parallel printer. (See DN-7103.) on a CHS-6 chassis in a BB-25. N-ANN-I/O: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional). Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation. Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-ISO(DN-6994),NP-100 series custom graphic annunciators. (DN-6995), N1-100(DN-6996), NH-100 series(DN-6997), ND-100 g p series (DN-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator: 80-char- NDM-100/NZM-100 (DN-6999), NC-100/1VC-100R (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-8G12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the FireWarden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(ON- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100: Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IOC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.)electrical box. Notification DN-60602:A1 •12/07/2010—Page 3 of 6 FireWarden-100-2 Rev 3 f-- Fire Alarm Control/ ANN-BUS or Communicator ANN-BUS DEVICES EIA-485 N-ANN-80,N-ANN-LED, in ACS mode N-ANN-S/PG,N-ANN-I/O (two wires) ---- n SMOKE DETECTORS 24 VDC ;"�sq r NP-100,NP-100T, • ► NI-100, NP-Al 00 I Ir .l I Optional =o cm f-•---- REVERSE m°rim POLARITY/ HEAT DETECTORS =v nm CITY BOX NH-100,NH-100R,NH-100H =o n. OUTPUT MEI FINN 1111 l l 1 (4XTM) - 0 ANNUNCIATORS _ =El UM ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS NOTE:System can use (optional,order ACM-SR) ND-100,ND-100R, DNR either ANN-BUS devices OR ACS-mode annunciators. o o o 0 They cannot be used simultaneously. NACs(Notification iii Appliance Circuits) • BELLS. SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into plEialliter the motherboard ba • mil iii __,, l ! ! ie 0000a ADDLE MULTI-MODULE PRINTER ' NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They e.V 4.i cannot be used simultaneously. rr EIA-485 INTERFACE 24 VDC • I` (four wires) MINI-MONITOR ► _ - _--_ NMM-100P 00000 FIRE FDU-80 • Li s Up to 6,000 ft.(1825.8 m) between each FDU-80 in the EIA-485 loop,and between PULL STATION a each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 DN-60602:A1•12/07/2010—Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep. Trim Ring(TR-CE- B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Intelligent Signalling Line Circuits 1 • Addressable device capacity 198 Shipping Specifications • Programmable software zones 99 • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) • ANN-bus devices 16 high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32-120°F and at a relative humidity 93%t 2%RH(non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C ± 2°C (90°F ±3°F). However, the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet.Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15-27°C/60-80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y (Class B) for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B) or with an optional ZNAC-92 module converts to four -LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z(Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 UL listed)for Style Y(Class B) NAC.Refer to panel documenta- -AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed com- 4XTM). patible devices. -REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps © 30 VDC (resistive),0.5 amps © 30 alarm,trouble and supervisory relays may be connected to VAC(resistive). Form-C relays. UL 864 listed transmitters.For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettabie Power (24 VDC Noml- _PROPRIETARY (Automatic, Manual, Waterflow and Sprin- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- put.Power-limited. -CENTRAL STATION (Automatic, Manual, Waterflow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. -OT,PSDN(Other Technologies, Packet-switched Data Net- Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel. In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed:S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and Excederm is a trademark of Cooper Notification. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document Is strictly prohibited. i ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. __E R T F 1 E O We cannot cover all specific applications or anticipate all requirements. ENCIfEENIM&MlWIFACTINN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 dn-6927:a FCPS-24S6(C/E) & FCPS- N OT 1 F 1 E R° 24S8(C/E) 6- & 8-Amp 24-Volt by Honeywell Remote Power Su lies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are •'" remote power supplies with battery charger.The FCPS-24S6/- • 24S8 may be connected to any 12 or 24 volt fire alarm control y panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAG)expansion(to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to four notification appliance circuits configured as either four Class B(Style Y)or Class A(Style Z, ( O with ZNAC-4 option module).Alternately, the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. • NOTE Unless otherwise specified the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the ' FCPS-24S6E and FCPS-24S8E . . awe Features • Includes integral battery charger capable of charging up to • UL-Listed NAC synchronization using System Sensor, 18 AH batteries.Cabinet capable of housing 7.0 AH batter- Wheelock,or Gentex"Commander2"appliances. ies. • Operates as a "sync-follower" or as a "sync-generator" • Battery charger may be disabled via DIP switch for applica- (default). See note on page 2. tions requiring larger batteries. • Contains two fully-isolated input/control circuits - triggered • Fixed, clamp-type terminal blocks accommodate up to 12 from FACP NAC (NAC expander mode)or jumped perma- AWG(3.1mm2)wire. nently"ON"(stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with Specifications ZNAC-4 module)NACs. Primary(AC)Power: • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- put, with 3 amps maximum/circuit, in NAC expander mode • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. (UL 864). • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. • 4-amp (FCPS-2456) or 6-amp (FCPS-24S8) continuous • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- output in stand-alone mode(UL 1481). tion. • Compatible with coded inputs;signals passed through. Control Input Circuit: • Optional power-supervision relay(EOLR-1). • Trigger Input Voltage: 9 to 32 VDC. • In stand-alone mode, output power circuits may be config- • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 ured as: resettable, (reset line from FACP required), -16 V). non-resettable,or a mix of two and two. Trouble Contact Rating: 5 A at 24 VDC. • Fully regulated and filtered power output-optimal for pow- Auxiliary Power Output: Specific application power 500 mA eying four-wire smoke detectors, annunciators, and other maximum. system peripherals requiring regulated/filtered power. • Power-limiting technology meets UL power-limiting require- Output Circuits: ments. • +24 VDC filtered,regulated. • Form-C normally-closed trouble relay. • 3.0 A maximum for any one circuit. • Fully supervised power supply,battery,and NACs. • Total continuous current for all outputs(stand-alone mode): • Selectable earth fault detection. –FCPS-24S6: 4.0 A maximum. • AC trouble report selectable for immediate 2-hour delay. –FCPS-24S8: 6.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- • Total short-term current for all outputs(NAC expander mode): lizes an industry-standard reverse-polarity notification cir- –FCPS-24S6: 6.0 A maximum. cuit(including unfiltered and unregulated bell power). –FCPS-24S8: 8.0 A maximum. • Requires input trigger voltage of 9-32 VDC. Self-contained in compact, locking cabinet- 15'H x 14.5"W Secondary Power(Battery)Charging Circuit: • x 2.75"D(cm:38.1 H x 36.83W x 6.985D). • Supports lead-acid batteries only. • Float-charge voltage: 27.6 VDC. dn-6927:a•04/30/09—Page 1 of 2 • Maximum current charge: 1.5 A. Standards and Codes • • Maximum battery capacity: 18 AH. The FCPS-24S6 and FCPS-24S8 comply with the following Applications standards: • NFPA 72 National Fire Alarm Code. Example 1:Expand notification appliance power an additional • UL 864 Standard for Control Units for Fire Alarm Systems 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four (NAC expander mode). Class B (Style Y) outputs or four Class A (Style Z) outputs • UL 1481 Power Supplies for Fire Alarm Systems. (using ZNAC-4). For example,the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation occurs. Trouble conditions on the FCPS are sensed by the Agency Listings and Approvals FACP through the notification appliance circuit. These listings and approvals apply to the modules specified in Example 2: Use the FCPS to expand auxiliary regulated 24- this document. In some cases,certain modules or applications volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A may not be listed by certain approval agencies, or listing may (FCPS-24S8). Both resettable and non-resettable power be in process.Consult factory for latest listing status. options are available. Resettable outputs are created by con- • UL Listed: S635,S674 necting the resettable output from the FACP to one or both of ULC Listed:S635(FCPS-24S6C&FCPS-24S8C • the FCPS inputs. ( FCPS-24S8C) Example 3: Use addressable control modules to activate the • CSFM Approved: 7315-0028:225 FCPS instead of activating it through the FACP notification • MEA: 299-02-E appliance circuits.This typically allows for mounting the FCPS • FM Approved at greater distances` away from the FACP while expanding system architecture in various applications. Ordering Information For example, an addressable control module is used to acti- FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. vate the FCPS,and an addressable monitor module is used to Includes main printed circuit board, transformers, enclosure sense FCPS trouble conditions. Local auxiliary power output (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and from the FCPS provides power to the addressable control installation instructions. module. FCPS-24S6C: Same as above,ULC-listed. `NOTE:Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Sync Follower/Generator Note Includes main printed circuit board, transformers, enclosure In some installations, it is necessary to synchronize the flash (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.9850]),and timing of all strobes in the system for ADA compliance. installation instructions. Strobes accomplish this by monitoring very short timing pulses FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. on the NAC power which are created by the FACP. When Includes main printed circuit board, transformers, enclosure installed at the end of a NAC wire run,the FCPS-24S6/-24S8 (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and can track (i.e. "follow') the strobe synchronization timing installation instructions. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8C Same as above, ULC-listed. system flash timing of the additional strobes attaches to the FCPS. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. When the FCPS-2456/-2458 is configured(via DIP switch set- FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. tings)as a "sync follower,"the FCPS's NAC outputs track the Includes main printed circuit board, transformers, enclosure strobe synchronization pulses present at the FCPS's sync (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and input terminal.The pulses originate from an upstream FACP or installation instructions. other power supply. ZNAC-4: Class A(Style Y)NAC option module. When the FCPS-24S6/-24S8 are configured (via DIP switch EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire settings) as a "sync generator," the FCPS's sync input fermi- smoke detector power. nals are not used. Rather, the FCPS is the originator of the BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT strobe synchronization pulses on the FCPS's NAC outputs. In Series data sheet DN-6933). "sync generator"mode,the sync type(System Sensor, Whee- lock,or Gentex)is selectable via DIP switch settings. PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor®and NOTIFIER®are registered trademarks of Honeywell International Inc. ©2009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used tor installation purposes. I I I 101 We try to keep our product information up-to-date and accurate. c F a r F I F n We cannot cover all specific applications or anticipate all requirements. BERM E 1W111111111111 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)464-7118. www.notifier.com Page 2 of 2—dn-6927:a•04/30/09 DN-7087:Cl SpectrAlert® Advance N OT Fl E Ft Selectable Output �V Notification Appliances by Honeywell Audio/Visual Devices sie+t General - System Sensor® SpectrAlert® Advance selectable-output horns,strobes and horn/strobes are rich with features guaran- °-% ° a` $ teed to cut installation times and maximize profits.The Spec- x `�• trAlert Advance series of notification appliances is designed to '', ,t ' simplify s p fy your installations, with features such as: plug-in Indoor Ceiling Outdoor Strobe Ceiling tion of Individual devices, and eleven field-selectable candela settings for wall and ceiling strobes and horn/strobes. / More specifically, when installing Advance products, first , attach a universal mounting plate to a tour-inch square, four- 4 f b inch octagon, or double-gang junction box. The two-wire �� - mounting plate attaches to a single-gang junction box. Then, connect the notification appliance circuit wiring to the .,....--9 °" " a SEMS terminals on the mounting plate. Indoor Wall Indoor Ceiling Finally,attach the horn,strobe,or horn/strobe to the mounting Horn/Strobe Strobe plate by inserting the product's tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- uct's pins into the mounting plate's terminals. The device will ^+; temporarily hold in place with a catch until it is secured with a - ' ' captured mounting screw. I SpectrAlert Advance products allow you to choose: f dc. • 12 or 24 volts. Indoor Wall Outdoor Wall • 15, 15/75,30,75, 95, 110, 115, 135, 150, 177,or 185 can- Horn Wow/Strobe dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from-40°F and 151°F(-40°C and ing window. 66°C). • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and • The SpectrAlert Advance series includes outdoor notifica- weatherproof per NEMA 4X, IP56 tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox. wire and four-wire)are available for wall or ceiling.Outdoor • Horn rated at 88+dbA at 16 volts. horns are available for wall only.All System Sensor outdoor • Rotary switch for tone selection. products are rated between -40°F and 151°F (-40°C and • 66°C)in wet or dry applications.66°C) horn volume settings. Models available: • Electrically compatible with existing SpectrAlert products. • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire Engineering Specifications horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAlert Advance horns, strobes, and horn/strobes shall horn/strobe. mount to a standard 4.0' x 4.0' x 1.5' (10.16 x 10.16 x 3.81 • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4- cm)backbox,4.0'(10.16 cm)octagonal backbox,or a double- • oornwall-m gang backbox.Two-wire products shall also mount to a single- gang 2.0'x 4.0'x 1.875'(5.08 x 10.16 x 4.763 cm)backbox.A • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling horn/strobe. and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- Features trAlert Advance products, when used with the Sync•Circuitn• Module accessory, shall be powered from a non-coded notifi- • Plug-in design. cation appliance circuit output and shall operate on a nominal • Same mounting plate for wall-and ceiling-mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12- • Shorting spring on mounting plate for continuity check volt rated notification appliance circuit outputs shall operate before installation. between 9 and 17.5 volts; 24-volt rated notification appliance • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor SpectrAlert Advance products shall operate between 32°F and • Tamper-resistance capability. 120°F(0°C and 49°C)from a regulated DC, or full-wave-recti- • Field-selectable candela settings on wall and ceiling units: Pied, unfiltered power supply. Strobes and horn/strobes shall 15, 15/75,30,75,95, 110, 115,135, 150, 177, 185. have field-selectable candela settings Including 15, 15/75, 30, • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95, 110, 115, 135, 150, 177, 185. 1 75 candela, • Outdoor wall and ceiling products. DN-7087:C1•11/9/1 1—Page 1 014 STROBE Operating Specifications The strobe shall be a System Sensor SpectrAlert Advance • Standard operating temperature: 32`F to 120°F (0°C to Model listed to UL 1971 and shall be approved for fire 49°C) protective service.The strobe shall be wired as a primary-sig- • K Series operating temperature: -40°F to 151°F (-40°C naling notification appliance and comply with the Americans to Series with Disabilities Act requirements for visible signaling appli- ances,flashing at 1 Hz over the strobe's entire operating volt- • Humidity range: 10% to 93% non-condensing (indoor age range.The strobe light shall consist of a xenon flash tube products). and associated lens/reflector system. • Strobe flash rate: 1 Ilash per second. HORN/STROBE COMBINATION • Nominal voltage: regulated 12 VDC/FWR or regulated 24 Wave Rectified(FWR) voltage is a VDC/FWR. NOTE:Fu The horn strobe shall be a System Sensor SpectrAlert Full Advance Model listed to UL 1971 and UL 464 and non-regulated, time-varying power source that is used on some power supply and panel outputs. shall be approved for fire protective service. The horn/strobe Operating voltage range:8 V to 17.5 V(12 V nominal);or shall be wired as a primary-signaling notification appliance 16 V to 33 V(24 V nominal). NOTE:P, S,PC,and SC prod- and comply with the Americans with Disabilities Act require- ucts will operate at 12 V nominal only for 15 cd and 15/75 ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall cd. consist of a xenon flash tube and associated lens/reflector sys- • Input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 tern.The horn shall have three audibility options and an option mni), to switch between a Temporal 3 pattern and a Non-Temporal • Ceiling-mount dimensions (including lens): 6.8' diame- (continuous)pattern.These options are set by a multiple posi- ter x 2.5'deep(17.3 cm diameter x 6.4 cm deep). tlon switch.On four-wire products,the strobe shall be powered • Wall-mount dimensions(Including lens):5.6'H x 4.7'W independently of the sounder.The horn on horn/strobe models x 2.5' D(14.2 cm H x 11.9 cm W x 6 4 cm D). shall operate on a coded or non-coded power supply. • Horn dimensions: 5.6" H x 4.7" W x 1.3" D (14.2 cm H x OUTDOOR PRODUCTS 11.9 cm W x 3.3 cm D). SpectrAlert Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate Agency Listings and Approvals between -40°F and 151°F (-40°C and 66°C). The products The listings and approvals below apply to SpectrAlert Advance shall be listed for use with a System Sensor outdoor/weather- Selectable Output Notification Devices. In some cases,certain proof backbox with halt-inch and three-fourths-inch conduit modules may not be listed by certain approval agencies, or entries. listing may be in process. Consult factory for latest listing sta- SYNCHRONIZATION MODULE tus. The module shall be a System Sensor Syn •Circuit MDL3R or • UL Listed: S4011 (HR_, HW_, P2 , P4_, PC2_, MDL3W listed to UL 464 and shall be approved for fire protec- PC4_ models); S5512 (models SCR, SCRH, SCW, five service.The module shall synchronize SpectrAlerl strobes SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, at 1 Hz and horns at Temporal 3. Also, while operating the SRHK,SRK). strobes, the module shall silence the horns on horn/strobe • ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models over a single pair of wires.The module shall mount to models, with exception of outdoor strobes). See Canadian a 4.688• x 4.688"x 2.125"(11.906 x 11.906 x 5.398 cm)back- data sheet for listings and specifications. box. The module shall also control two Style Y (class B) cir- . FM approved cuits or one Style Z (Class A) circuit. The module shall MEA:452-05-E synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, they control. The module shall not operate on a coded power SRH,SW,SWH);7300-1653:0188(P2_, P4_,PC2_, PC4_. supply. modules); 7135-1653:0189 (HR. HRK, HW); 7300- 1653:0187(SCRHK,SCRK,SRHK,SRK). Strobe Current Draw, Horn Current Draw, UL Maximum (mA RMS) UL Maximum (mA RMS) 8-17.5V 16-33V Sound 8-17.5V 16-33V Candela Pattern dB DC FWR DC FWR DC FWR DC FWR 15 123 128 66 71 Temporal High 57 55 69 75 '15/75 142 148 77 81 Temporal Medium 44 49 ' 58 69 Standard 30 NA N/A 94 96 Temporal Low 38 44 44 48 Candela 75 NA NA 158 153 Non-temporal High 57 56 69 75 Range '95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 135 NA NA 228 207 Coded Medium 44 51 56 69 High 150 NA NA 246 220 Coded Low 40 46 52 50 Candela '177 NA NA 281 251 Range 185 NA NA 286 253 Page 2 of 4—DN-7087.C1•11/9111 Horn and Horn/Strobe Horn and Horn/Strobe Output (dBA) Rotary Switch Setting 8-17.5V 16-33 V Setting Repetition Rate dB Level Switch Sound dB Position Pattern DC FW DC FW 1 Temporal horn High R R '2 Temporal horn Medium 1 Temporal High 78 78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 - Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 Externally coded High 6 Non-temporal Low 75 75 81 81 8' Externally coded Medium 7' Coded High 82 82 88 88 9' Externally coded Low 8* Coded Medium'78 78 85 85 *NOTE:Settings 7,8,and 9 are not available 9* Coded Low 75 175 81 81 on 2-wire horn/strobe. 'NOTE:Settings 7, 8,and 9 are not available on 2-wire horn/strobe. Two-Wire Horn/Strobe, STANDARD Candela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) Input, Sound Pattern,dB 8-17.5 V 16-33 V Level 15 15/75 15 15175 30 75 95 110 115 DC Input,Temporal,High 137 147 79 90 107 176 194 212 218 DC Input.Temporal,Medium 132 144 69 80 97 157 182 201 210 DC Input,Temporal,Low 132 143 66 77 93 154 179 198 '207 DC Input,Non-temporal,High 141 152 91 100 116 176 201 221 229 DC Input,Non-temporal,Medium 133 145 75 85 102 163 187 207 216 DC Input,Non-temporal,Low 131 144 68 79 96 156 182 201 210 FWR Input,Temporal,High 136 155 88 97 112 168 190 210 218 FWR Input,Temporal,Medium 129 152 78 88 103 160 184 202 206 FWR Input,Temporal,Low 129 151 76 86 101 160 184 194 201 FWR Input,Non-temporal,High 142 161 103 112 126 181 203 221 229 FWR Input,Non-temporal,Medium 134 155 85 95 110 166 189 208 216 FWR Input,Non-temporal,Low 132 154 80 90 105 161 184 202 211 Two-Wire Horn/Strobe, H/GHCandela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS) 16-33V 16-33 V DC Input FWR Input 135 150 177 185 135 150 177 185 DC,Temporal,High 245 259 290 297 FWR,Temporal,High 215 231 258 265 DC,Temporal,Medium 235 253 288 -297 FWR.Temporal,Medium 209 224 250 258 DC,Temporal,Low 232 251 282 292 FWR,Temporal,Low 207 221 248 256 DC,Non-temporal,High 255 270 303 309 FWR,Non-temporal,High 233 248 275 281 DC,Non-temporal,Medium 242 259 293 299 FWR. Non-temporal,Medium 219 232 262 267 DC,Non-temporal,Low 238 254 291 295 FWR,Non-temporal,Low 214 229 256 262 7O 7o-m,xoe in 4.7" tI ,.�- 6.8" � -III " _�j IJi1I56 2.5'. DN-7087:C1•1119/11—Page 3 o1 4 • Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire horNstrobe,standard cd,red. PC2R 2-wire horn/strobe,standard cd,red. P2RH 2-wire homstrobe,high cd,red. PC2RH 2-wire hom/strobe,high cd,red. P2RK 2-wire horn/strobe,standard cd,red,outdoor. PC2RK 2-wire hornstrobe,standard cd,red,outdoor. P2RHK 2-wire horn/strobe,high cd,red,outdoor. PC2RHK 2-wire homstrobe,high cd,red,outdoor. P2W 2-wire horn/strobe,standard cd,white. PC2W 2-wire horn/strobe,standard cd,white. P2WH 2-wire horn/strobe,high cd,white. PC2WH 2-wire hom/strobe,high cd,white. P4R 4-wire hom/strobe,standard cd,red. PC4R 4-wire homstrobe,standard cd,red. P4RH 4-wire hornstrobe,high cd,red. PC4RH 4-wire homstrobe,high cd,red. P4RK 4-wire horn/strobe,standard rd,red,outdoor, PC4RK 4-wire horNstrobe,standard cd,red,outdoor. P4RHK 4-wire horn/strobe,high cd,red,outdoor. PC4RHK 4-wire horNstrobe,high cd,red,outdoor. P4W 4-wire horn/strobe,standard cd,white. PC4W 4-wire horn/strobe,standard cd,white. P4WH 4-wire horn/strobe,high cd,white. PC4WH 4-wire horNstrobe,high cd,white. WALL STROBES CEILING STROBES SR Strobe,standard cd,red. SCR Strobe,standard cd,red. SRH Strobe,high cd,red. SCRH Strobe,high cd,red. SRK Strobe,standard cd,red,outdoor. SCRK Strobe,standard cd,red,outdoor. SRHK Strobe,high cd,red,outdoor. SCRHK Strobe,high cd,red,outdoor. SW Strobe,standard cd,white. SCW Strobe,standard cd,white. SWH Strobe,high cd,white. SCWH Strobe,high cd,white. ACCESSORIES HORNS BBS-2A Backbox skirt,wall,red. HR Horn,red. BBSW-2A Backbox skid,wall,white. HRK Horn,red,outdoor. BBSC-2A Backbox skid,ceiling,red. HW Horn,white. BBSCW-2A Backbox skirt,ceiling,white. ACCESSORIES,continued SA-WBB Weatherproof backbox,wall. TR-HS Trim Ring,wall,red,package of 5 SA-WBBC Weatherproof backbox,ceiling. TRW-HS Trim Ring,wall,white,package of 5 WTP Weatherproof,flush mount plate,red TRC-HS Trim Ring,ceiling,red,package of 5 WTPW Weatherproof,flush mount plate,white TRCW-HS Trim Ring,ceiling,white,package of 5 NOTE: "High cd'refers to strobes that include 135, 150, 177, and 185 candela settings. "Standard cd"refers to strobes that include 15, 15/75,30, 75,95, 110,and 115 candela settings. NOTE: For strobes and horn/strobes,add suffix"F"for French or"B"for Bilingual. NOTE: All outdoor models("K(A)"suffix)include a plastic weatherproof backbox. NOTE: Add"-A"to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW, NOTE: Add"P'to model for plain housing. (No FIRE"marking on cover.) Sync•Circuit • Is a trademark and NOTIFIER® and SpectrAlert® are registered trademarks of Honeywell International Inc. 62011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. inlitUR All specifications are subject to change without notice. IISLITY SYSTEMS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www,notifier.com Page 4 0l 4—DN-7087:C1•11/9/11 DN-6995:C•Al-320 NP-100(A) Series ® NOTIFIER® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with j} NOTIFIER's FireWarden Series(FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (57°C). • Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a 40111010.111141v local,visible sensor indication. Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A)in B210LP(A) Base DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability,especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often Addressing better than photoelectric detectors at sensing fast, flaming fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP-25,and 01 –50 with FireWarden-50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple base to simplify installation,service and maintenance. field cleaning. Mount base(all base types)on an electrical backbox which is Operation at least 1.5'(3.81 cm)deep. For a chart of compatible junction boxes,see DN-60054. • Withstands air velocities up to 4,000 feet-per-minute (20 m/ sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC • Factory preset at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring "T-taps" or branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed (communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0' (10.16 cult (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0"(10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly coated circuit boards and superior RF/transient pro- formly to a broad range of smoke conditions. It can withstand • wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar cham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a Options more stable detector. • Remote LED output connection, PN RA100Z(A). DN-6995:C•12/07/2011 —Page 1 of 2 Detector Sensitivity Test NP-100RA: Same as NP-100R with ULC Listing for use with a DNRA duct detector housing; B210LPA base included. Each detector can have its sensitivity tested (required per NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NOTE:A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15-32 VDC(peak). 6210LPBP: Bulk pack of B210LP;package contains 10. Standby current:300 pA 0 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA 0 24 VDC(latched"ON"). B501BP: Bulk pack of B501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1'(5.33 cm)high;base determines diameter. Replaces 8501 BH series bases in retrofit applications. -B210LP(A):6.1'(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1'(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 -B200SR(A):6.875"(17.46 cm)diameter. A 0 30 VDC resistive; 0.3 A © 110 VDC inductive; 1.0 A -B224RB(A):6.2'(15.748 cm)diameter. 30 VDC inductive. Weight:3.6 oz.(102 g). B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F);for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C-49°C(32°F-120°F). low-profile. Relative humidity: 10%-93%,non-condensing. F110BP: Bulk pack of Fl 10;package contains 15. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3-32 VDC.Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit listing may be in process. Consult factory for latest listing sta- M02-04-00:Test magnet. tus. • UL Listed:S7115. M02-09-00:Test magnet with telescoping handle. • ULC Listed:5911. XR2B: Detector removal tool. Allows installation and/or CSFM:7272-0028:0231. removal of detector heads from bases in high ceiling applica- • CSFM:7272-0028:0231. tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-toot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010:Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:"A"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B210LP base only;box of 10. included. NP-100A: Sames as NP-100 with ULC Listing; B21OLPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B21OLPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International Inc. B210LP base included. ®2011. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F 1 E O We cannot cover all specific applications or anticipate all requirements. fililrfBlNi IMMURING All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:C•12/07/2011 DN-6820:6•D-123 80 FDU-80 er Liquid Crystal Display ® NOTIFIER® by Honeywell Annunciators General The FDU-80 is a compact,cost-effective, 80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels(FACPs).The FDU-80 mimics the display of the control panel and displays complete system point status information. CS==Mg •••• Up to 32 FDU-80s may be connected onto the EIA-485 termi- nal port of each FACP.The FDU-80 requires no programming, which saves time during system commissioning. Features a E-±1 • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, - — Drill and Reset with enable key. 68201eue.ipg • System status LEDs for Power,Alarm,Trouble,Supervisory and Alarm Silenced. • No programming necessary—FDU-80 connects to the ter- Ordering Information minal porton the FACP. FDU-80: 80 character,backlit,LCD Fire Annunciator with con- • Displays device type identifiers, individual point alarm,trou- trol switches for remote control of system functions, and key- ble or supervisory,zone and custom alpha labels. switch lock. • Time-and-date display field. FDU-80C:ULC-listed version;see DN-60573 for details. • Aesthetically pleasing design. 10103:Three-gang electrical box, minimum 2.188"(5.556'cm) • May be powered from the host FACP or by remote power deep,for semi-flush mount applications. supply(requires 24 VDC). SBB-3: Three-gang surface backbox for surface-mount appli- • Up to 32 FDU-80 annunciators per FACP. cations. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from Agency Listings And Approvals the FACP. These listings and approvals apply to the modules specified in • Local piezo sounder with alarm and trouble resound. this document.In some cases,certain modules or applications • Semi-flush mounts to 2.188" (5.556 cm) minimum deep, may not be listed by certain approval agencies, or listing may three-gang electrical box (NOTIFIER PN 10103) or three- be in process.Consult factory for latest listing status. gangable electrical switchbox. • UL Listed:S635 • Surface-mounts to NOTIFIER PN SBB-3 surface backbox. • MEA Listed:245-00-E • FDNY:COA#6038 Operation • CSFM:7120-0028:209 The FDU-80 annunciator provides the FACP with point annun- • FM Approved ciation with full display text on an 80-character LCD display. NOTE:For ULC-listed version,see DN-60573. The FDU-80 also provides an array of LEDs to indicate system status,and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:B•05/17/2010—Page 1 of 2 • NOTIFIER®is a registered trademark of Honeywell International Inc. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I O �oo 1 J This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EfiCINERIIIC 6MNYSTIMS All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6820:B•05/17/2010 DN-7001:D•Al-380 NOT-BG 12LX ® N OT I F I E R° Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels, and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the exact location 01 the activated manual station. This leads fire personnel quickly to the location of the alarm. tt Features• Maintenance personnel can open station for inspection and address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. e• Captive screw terminals wire-ready for easy connection to 3 SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4' (10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3113]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4' • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch • Meets UL 38, Standard for Manually Actuated Signaling in the down/activated position. Once latched,the word"ACTI- Y 9 g VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station, simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 –99 on NFW2-100/NFW2-100C, 1 –50 for NFW-50/NFW- • Shipping Weight:9.6 oz. (272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 NA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that atter actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BGI2LX is being semi-flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted,then the optional trim ring (BG12TR) may be used. mounting on a standard single gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed ON-7001:D•4/13/2012—Page I of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-1/0: Surface backbox;plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • ULNLC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIERS is a registered trademark of Honeywell International Inc. C2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E re r r F r E o We cannot cover all specific applications or anticipate all requirements. amain AMBIMi All specifications are subject to change without notice. QSALITT SYSTEM Made in the U.S A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 DN-60424:B1 InnovairFlex NOTI Fl E R® Conventional Duct Smoke Detectors by Honeywell Conventional Initiating Devices General Notifier InnovairFlex photoelectric smoke detector tea ; tures a pivoting housing that fits various applications: both square and rectangular footprints mount to round or rectangu- 1„,„'- lar duct work. - This new duct smoke detector senses airflow speeds ranging —— from 100 to 4,000 feet per minute with proven precision. The enhancements built into this model improve false alarm immu- nity(with plug-in sensor head);broaden operating temperature $ (-4°F to 158°F, -17°C to 70°C) and humidity (0 to 95 percent non condensing) ranges; while simplifying installation and maintenance.These advance features can detect smoke even in the harshest duct applications. The new design provides more wiring space with an added 3/4 inch conduit knockout. Numbers and labels for terminal desig- nations are consistent with previous Innovair models. The new sampling tube can be clicked into position with one smooth Q WARNING: Duct smoke detectors have motion from either the front or the back of the detector. ti specific limitations. The Notifier InnovairFlex duct smoke detector has signals to Duct Smoke Detectors are: indicate trouble and maintenance conditions. Additionally, a • NOT a substitute for an open area smoke cover tamper feature is incorporated to indicate a trouble con- detector dition when the sensor cover is removed or improperly • NOT a substitute for early warning detection, and installed. An improved cover design, with an integrated low- •NOT a replacement for a building's regular fire flow feature, isolates the sensor head from the low-flow tech- detection system. nology for simple maintenance. The Notifier InnovairFlex series is designed for greater flexibil- ity and reliable smoke detection to simplify installation and maintenance. The new InnovairFlex product line is backward Specifications compatible to existing Innovair models, including remote test Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) accessories. Width,2.5 in(6.36 cm)Depth. Features Size:(Square)7.75 in(19.7 cm)Length;9 in(22.9 cm)Width; 2.5 in(6.35 cm) Depth. • Photoelectric, integrated low-flow technology. Weight: 1.8 lb(0.82 kg). • Air velocity rating from 100 ft/min to 4,000 ft/min(0.5 m/s to 20.32 m/sec). Operating Temperature Range: (-4°F to 158°F, -17°C to • Versatile mounting options in square or rectangular configu- 70°C). ration with modular construction. Storage Temperature Range: -22°F to 158°F (-30°C to • Plug-in sensor. 70°C). • Superb false alarm immunity with the latest sensor technol- Operating Humidity Range: 0% to 95% relative humidity ogy. (non-condensing). • Broader ranges for operating temperature (-4°F to 158°F, Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s). -17°C to 70°C)and humidity(0%to 95%non-condensing). ELECTRICAL RATINGS • Patented sampling tube installs from front or back of the Power supply voltage:8.5-35 VDC. detector with no tools required. • A cover tamper feature to indicate a trouble condition for Input capacitance:0.1 uF max. removed or improperly installed sensor cover. Reset voltage:2.5 VDC min. • Increased wiring space with a newly added 3/4" conduit Reset time(with RTS151):0.03 to 0.3 seconds. knockout. • Improved LED status. Reset time(by power down):0.3 seconds max. • 24 VDC. Power up time: 35 seconds max. • Backward compatibility with existing Innovair products, Alarm response time: 15 seconds. including remote accessories. Current Requirements:(Using No Accessories) —Peak standby current: 120uA. —Max standby current:60uA(average). —Max alarm current: 130mA. DN-60424:B1•10/5/2011—Page 1 of 2 ACCESSORY CURRENT LOADS AT 24 VDC terns. The flexible housing of the duct smoke detector fits both square and rectangular footprints.The detector shall operate at air velociites of 100 ft/min to 4,000 ft/min(0.5 m/sec to 20/32 m/ Device Standby Alarm sec). The unit shall be capable of providing a trouble signal in RA100Z OmA 12 mA Max the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch RTSI51 OrnA 12mA Max or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method RTS151KEY 12mA 12mA Max suitable for 12-18 AWG wiring. Product Line Information Agency Listings and Approvals Consult product manual for lists of compatible UL-Listed D2: InnovairFlex duct detector, includes 2-wire photo electric devices. In some cases,certain modules may not be listed by low-flow duct smoke detector. certain approval agencies, or listing may be in process. Con- D4120: InnovairFlex duct detector,includes 4-wire photo elec- sult factory for latest listing status. tric low-flow duct smoke detector. UL Listed:268A D4120W: InnovairFlex duct detector, includes watertight 4- ULC Listed wire photo electric low-flow duct smoke detector. CSFM: 3242-1653:0206 (D2), 3242-1653:0207 (D4120, D4P120: InnovairFlex duct detector, includes 4-wIre photo- D4P120, D4S) electric power board component only,24VAC/DC, 120VAC. FM approved 2151: Replacement 2 wire conventional photo electrical sen- sor head. 2D51: Replacement 4-wire conventional photo electrical sen- sor head. D4S:4-wire photo electric sensor component only. DCOIL: 2 wire remote test coil required with RTS151/ RTS151KEY. DST1: Metal sampling tube duct width up to 1 ft(0.3m). DST1.5: Metal sampling tube duct widths up to 1 ft to 2 ft(0.3 to 0.6 m). DST3:Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5:Metal sampling tube duct widths up to 4 ft to 8 ft(1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft(2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. RTS151: Remote test station. RTS151KEY: Remote test station with key lock. RTS2:Multi-signaling accessory(4-wire). AOS:Add-on strobe,optional accessory tor RTS2. RTS2-AOS: Multi-signaling accessory (4-wire); includes AOS add-on strobe. Architectural / Engineering Specifications Notifier® and FlashScan® are a registered trademark of Honeywell International Inc. The air duct smoke detector shall be a Notifier InnovairFlex D2 02011 by Honeywell International Inc.All rights reserved.Unauthorized use Photoelectric duct smoke detector. The detector housing shall of this document is strictly prohibited. be UL listed per UL 268A specifically for use in air handling sys- ISO 900 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. EMMELINE I MANIF ciIMNC All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-60424:81•10/5/2011 DN-6994:B•A1-370 N100-ISO(A) NOTIFIER`� Fault Isolator Module for FireWarden Series Panels by Honeywell Addressable General The NOTIFIER N100-ISO(A) Fault Isolator Module is used with FireWarden Series panels to protect the system against wire-to-wire short circuits on the SLC loop. The N100-ISO(A) should be placed between each device on the SLC loop to iso- late a short-circuit problem between the modules. It is required for true Style 7 operation so that other devices can continue to operate normally in the event of a short-circuit on the SLC. Features • Powered by SLC loop directly,no external power required. • Mounts in standard junction boxes (4.0/10.16 cm square, 2.125'/5.398 cm deep). • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is detected. • High noise(EMF/RFI)immunity. Applications The Fault Isolator Modules should be spaced between groups of sensors in a loop to protect the rest of the loop. Use to iso- late short circuit problems within a section of a loop so that other sections can continue to operate normally. The N100- I50(A) supports a maximum of 25 devices in-between isola- N100-1S0(A) tors,except when using relay bases. NOTE:LOADS PER RELAY BASE AND ISOLATORS/ISOLATOR • Dimensions: 4.5"H x 4.5"W x 0.25" D (11.43 cm H x BASES: The maximum number of addressable devices between 11.43 cm W x 0.635 cm D). isolators(or 8224BIA isolator bases)is 25 devices. I— 25 DEVICES I Construction isolator isolator The face plate is made of off-white plastic. Module includes module —� module yellow LED indicator that pulses when normal and illuminates or base or base steady when a short is detected. 2243devices.wmf detector module Operation B224RB relay bases draw more current than other intelligent Automatically opens circuit when the line voltage drops below devices. When calculating the 25-device maximum, B224RB rep- four volts. addressable Isolator Modules should be spaced between resents 2.5 DEVICES;see example on page 2. groups of addressable devices (maximum 25, e , sae notes on page 1) in a loop to protect the rest of the loop. If a short NOTE: ON MAXIMUM NUMBER OF DEVICES: See the SLC occurs between any two isolators,then both isolators immedi- Manual(52304)for information on loss of addresses due to current ately switch to an open circuit state and isolate the groups of limitations. Each module or base added reduces the capacity of sensors between them. The remaining units on the loop con- address positions in an SLC.All SLC field devices must have been tinue to fully operate. purchased after February 1995 to meet the aforementioned requirements. If the SLC field devices were purchased prior to In Style 4 loops,the N100-ISO(A) is generally used at each T- February 1995,each isolator used reduces the capacity of an SLC tap branch,to limit the effect of short circuits on a branch to the by two address positions. Requirements differ as applied to relay devices on that branch. The LED indicator is on continuously bases;see note above. during a short circuit condition. The N100-ISO(A) Fault Isolator Module automatically restores Specifications the shorted portion of the communications loop to normal. • Operating voltage: 15—32 VDC(peak). • Maximum current upon activation due to short circuit: Installation refer to the manual for the main FRCP. • Mount on a standard junction box (4.0°/10.16 cm square) • Standby current: 450 pA maximum; N100-ISO(A) is not which is at least 2.125'/5.398 cm deep. isolating—relay closed. • Terminal screws are provided for"in and out"wiring. • Temperature range:32°F to 120°F(0°C to 49°C). • Installation instructions are provided with each module. • Relative humidity: 10%to 93%. • Surface-mount box is available as an option. • Weight:5 oz.(150 grams). DN-6994:B•01/05/2012—Page 1 of 2 • Engineering Specifications Agency Approvals and Listings • Fault Isolator Modules shall be provided to automatically iso- These listings and approvals apply to the modules specified in late wire-to-wire short circuits on an SLC loop.The Fault Isola- this document. In some cases,certain modules or applications tor Module shall limit the number of modules or detectors that may not be listed by certain approval agencies, or listing may may be rendered inoperative by a short circuit fault on the SLC be in progress.Consult factory for listing details. Loop. If a wire-to-wire short occurs, the Fault Isolator Module • UL Listed:S635. shall automatically open-circuit (disconnect) the SLC loop. • When the short circuit condition is corrected,the Fault Isolator CSFM:7300-0028:0238. Module shall automatically reconnect the isolated section of • MEA:427-91-E Vol.9. the SLC loop. The Fault Isolator Module shall not require any • FM Approved. address-setting,and its operations shall be totally automatic.It shall not be necessary to replace or reset an Fault Isolator Product Line Information Module after its normal operation. The Fault Isolator Module shall mount in a standard 4'(10.16 cm)deep electrical box, in NOTE:"A"suffix indicates ULC Listed model. a surface-mounted backbox, or in the Fire Alarm Control N100-ISO: Isolator module. Panel. II shall provide a single LED which shall flash to indi- cate that the Isolator is operational and shall illuminate steadily N100-ISOA:Same as N100-ISO with ULC Listing. to indicate that a short circuit condition has been detected and SMB500:Optional surface-mount backbox. isolated. Examples of Device Counts (see notes under Applications) Starts Next Count a; isolator _ isolator module module or base detector with detectorwith or base standard base relay base module Counts as... 1 + 3.5 + 1 = 5.5 Q (2.5+1) (less than 25 total) • Notifier®is a registered trademark of Honeywell International Inc. Notifier® and FireWarden® are registered trademarks of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'YO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E n r rr F r E o We cannot cover all specific applications or anticipate all requirements. M iMMIIFACTIAIN6 All specifications are subject to change without notice. UNITY SYSTEMS Made in the U.B.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484.7118. www.notifier.com Page 2 of 2—DN-6994:B•01/05/2012 Monitor Modules DN-6999C NMM-100(A), NMM-100P(A), N OT I F I E R NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact • input devices, such as conventional heat detectors and pull i stations, or monitor and power a circuit of two-wire smoke detectors(NZM-100(A)). " "- - _ - NMM-100(A)is a standard-sized module(typically mounts to a '1w ..attl' 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input ;"-"w-1lfiK[.20I111I:, devices. ; NMM-100P(A) is a miniature monitor module a mere 1.3" 1 14; 1:77,44-4," (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that '" „P"i �t supervises a Style B (Class B) circuit of dry-contact input (`E) �•�- devices. Its compact design allows the NMM-100P(A) to be c a, w4{ mounted in a single-gang box behind the device it monitors. NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt, smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a Built-in module to identification a control panel.id mal/short)of its Initiating Device Circuit(IDC). A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop. No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. NMM-100(A) SPECIFICATIONS • SEMS screws with clamping plates for ease of wiring. • Direct Decade entry of address: 01 - 99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 -50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 pA (LED flashing), 1 corn- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit(IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11,43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B)or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 NMM-100P(A) Mini Monitor Module Dimensions: 1.3' (3.302 cm) high x 2.75' (6.985 cm)wide x . Built-in type identification automatically identifies this device 0.65'(1.651 cm)deep. • as a monitor module to the panel. Wire length:6'(15.24 cm)minimum. • Powered directly by two-wire SLC loop. No additional power required. NZM•100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 – 99 on FireWarden- source. 100-2,01 –50 on FireWarden-50. • High noise(EMF/RFI)immunity. e • SEMS screws with clamping plates for ease of wiring. V 141 ' 1 ADDRESS 0 t • Direct Decade entry of address:, 01 –99 on FireWarden- P. 13 2 at 100-2,01 –50 on FireWarden-50. 1 3 • LED flashes during normal operation. 11 4 0 l • LED latches steady to indicate alarm on command from 10 9 6 5 —J g 6 control panel. TENS ONES The NZM-100(A) Interface Module is intended for use in intelli- nl I gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interlace and monitor two- 3 wire conventional smoke detectors.It transmits the status(nor- mal,open,or alarm)of one full zone of conventional detectors Q W Q back to the control panel. All two-wire detectors being moni- Ill j m tored must be UL compatible with the module. NM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke I I I I detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D (Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices, NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NMM-100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of its Initiating Device Circuit(IDC). A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,watertlow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- cuit. Maximum current draw:5.1 mA(LED on). NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 addresses on an SLC loop. It responds to regular polls from LED flash every 5 seconds,3.9k eol. the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current: 90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range: 10%to 93%noncondensing. Shorted). Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); The NDM-100(A) Dual Monitor Module is intended for use in 227-03-E Vol.3(NDM-100) intelligent, two-wire systems. It provides two independent two- wire Product Line Information initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire NOTE:"A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel- NMM-100(A): Monitor module. controlled LED. NOTE: The NDM-100(A)provides two Style B (Class B) IDC cir- NMM-100P(A): Monitor module, miniature. cults ONLY Style D(Class A) IDC circuits are NOT supported in NZM-100(A): Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual, two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw: 6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance: 47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. CAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125' (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances, and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances, and regulations, Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC: S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 Notifiet®and FireWarden®are registered trademarks and FireWatch,"Is a trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. C This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. UtUI.4111INI 6 MN JFAC11UN6 All specifications are subject to change without notice. IUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 dn-60383:A2 NC-100R(A) Relay Module for ® NOTIFIER® FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a variety of auxiliary devices,such as fans,dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- 1„, tact to be activated, either manually or through panel programming,on a select basis. lefie Features • Built-in type identification automatically identifies these •� ••- - devices to the control panel. '"°" _"...., ..,_„ • Internal circuitry and relay powered directly by two-wire v"c SLC loop. +• /1 1 • Integral LED "blinks" green each time a communication is `�J' •1 received from the control panel and turns on in steady when • activated. • • 1 1 • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 —99 with the FireWar- den-100-2(C)and 01 —50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders,Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll(CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x Operation 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status, The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Voltage Rating switches set a unique address for each module. The g g address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE(not settable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(UR=5ms) Coded 30 VDC 0.5 A Inductive(UR=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60383:A2•06/17/10—Page 1 of 2 • Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UUULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. • Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E a r F E o We cannot cover all specific applications or anticipate all requirements. All specifications are subject to change without notice. IUILIITT SYSTEMS Made in the U.S.A. For more Information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 o12—dn-60383:A2.06/17/10 • • JEFFERSON•UNTY DEPARTMENT OF COMMUNITVELOPMENT Automatic Fire Alarm System Fire Protection System Inspection Checklist: General • Building Permit No.: ..O•/4/- IJfV • Facility Owner/Mgr.: ..J E et/r • Facility Address: 4.3 /roe"-CdW4/ .r.e_ • Facility Name: _/di1 77t444' • Facility Contact No.: System: Iff'Manual Automatic ❑Voice ❑Monitored ❑Graphic ❑ Stand Alone Elements: / ❑ Heat ❑ Sate of Rise moke 0 Horn Cir o n/Strobe ❑ Strobe ❑Coiling Door •Manual Pulls IiY)uct ❑Egress Control ❑ Damper ❑ Other: Contractor's State License[&NICETI: Inspector Int.&Dt: Plan Review Inspector Int.&Dt: ❑ Plans Received[Date:09/ itj!] ❑ Mfr.Specifications of individdual elements f_At/K B mr/c/A/ ❑ Floor Plan(s)complete ❑ Battery Calculations,wring types and sizes. 40(/ e v j eW ,is"r-61) ❑ Power connection,Emergency Power Source 0/4" Sit Inspection Inspector lnt.& Dt.Ce2. System installation/location check-off lid" Panel Location emote Annunciation Access Keys 6e Labeling @' Operating Instructions..9"a7r1i>•' 4B-•Tools System Test(s) Ij ispector Int &Dt. Jr 4-44/ Heat ❑Rate of Rise gmoke ❑Horn 1orn/Strob 71 dct Egress Control anual Pull-station ❑,Strobe �✓ Vonitoring Agency Test rEmergency Power Sourcg y[ Fire Alarm System Inter-tie with Sprinkler System Test(Tamper): Secs."."-e/_ tso� /6-,"146 `'/ "''/ --9 Contractor's Material&Test Certificate: Inspector Int.&Dt.: As-Built Plans/Instructions in Plan Box an,F P OL✓N Inspector Int.&Dt.: Monitoring Agency '91.-/91-A4 C j T�- • Name:: • Address: 7k4r/ • /5 ,/,.A.0 NE f eZ.04€,MO • Contact Number: z4 GYF-4/7? • Account Number: imiwi361fft Panel Reset Code • Code Number: /• /. /././ / Approval/Denial • Inspector: • Date: • Filed wBldg.Official: 4/7 7/ri KNIGHT FIRE PROTECTION, INC. Jefferson Transit Authority iggr of 9702 LATHROP INDUSTRIAL DRIVE SW KFP Job No. 14-045 IRA A OLYMPIA, WA 98512-9188 il 11 (360) 786-8606 MATERIAL & TEST FAX 786-8722 REPORT FOR I I ABOVEGROUND PIPING °oN GUARD LICENSE NO. KNIGHFP044LK 24 HOURS A DAY" Procedure upon completion of work: Inspection and tests shall be made by the contractor's representative and witnessed by the AHJ. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty material, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME Jefferson Transit Authority DATE / PROPERTY ADDRESS 7` 63 Four Corners Road, Port Townsend, WA 98368 SYSTEM LOCATION OR ID _ REVIEWED AND ACCEPTED BY Jefferson County Fire Marshal PLANS ADDRESS INSTALLATION CONFORMS TO ACCEPTED PLANS 121 YES ❑NO EQUIPMENT USED IS APPROVED ® YES ❑ NO IF NO, EXPLAIN HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO ® YES ❑ NO .JSTRUCTIONS CARE AND MAINTENANCE OF THE NEW EQUIPMENT AND THE LOCATION OF ALL CONTROL VALVES? HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: 1. SYSTEM COMPONENT CARE, AND MAINTENANCE INSTRUCTIONS 1E1 YES ❑ NO 2. MAINTENANCE AGREEMENT ® YES ❑ NO MAKE MODEL S.I.N. YEAR THREAD K—FACT QTY. TEMP. Globe QR SSP GL5601 2012 1/2" 5.6K 51 200' SPRINKLERS Globe QR SSU GL5615 2012 1/2" 5.6K 9 200' Globe OR HSW GL5626 2012 1/2" 5.6K 9 200' Globe QR SSU GL8118 2012 3/4" 8.1K 6 200' Globe SR SSU GL8164 2012 3/4" 8.1K 47 200' Globe QR EC UPRIGHT GL1121 2012 3/4" 11.2K 5 20D' Globe DRY OR SSP GL5635 2012 1" 5.6K 1 200' Tyco SR EC HSW TY5332 2012 3/4" 8.0K 3 200' PIPE AND TYPE OF PIPE BLACK STEEL SCHEDULE 40 AND EDDYFLOW PIPE FITTINGS TYPE OF FITTINGS WELDED, CAST/MALLEABLE IRON, GROOVED WATER FLOW INDICATOR INFORMATION MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION ALARM LOCATION TYPE MAKE MODEL MIN. SEC. DEVICES UTILITY ROOM A138 Vane Potter VSR—S U 7 DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. N/A TIME TO TRIP * TIME WATER ALARM THROUGH TEST WATER AIR TRIP POINT REACHED OPERATED DRY PIPE CONNECTION PRESSURE PRESSURE AIR PRESSURE TEST OUTLET PROPERLY OPERATING MIN. SEC. PSI PSI PSI MIN. SEC. YES NO TEST WITHOUT Q.O.D. WITH Q.O.D. IF NO, EXPLAIN . • * MEASURED FROM THE TIME THE INSPECTORS TEST CONNECTION IS OPENED (OVER) . HYDROSTATIC: HYDROSTATIC TEST SHALL BE MADE AT NOT LESS THAN 200 PSI FOR TWO HOURS OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS. DIFFERENTIAL DRY—PIPE VALVE CLAPPERS SHALL BE LEFT OPEN DURING TEST TO PREVENT DAMAGE. ALL ABOVEGROUND PIPE TEST LEAKAGE SHALL BE STOPPED. DESCRIPTION PNEUMATIC: ESTABLISH 40 PSI AIR PRESSURE AND MEASURE DROP WHICH SHALL NOT EXCEED 1-1/2 PSI IN 24 HOURS. TEST PRESSURE TANKS AT NORMAL WATER LEVEL AND MEASURE AIR PRESSURE DROP WHICH SHALL NOT EXCEED 1-1/2 PSI IN 24 HOURS. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRS. IF NO, STATE REASON TESTS DRY PIPING PNEUMATICALLY TESTED ❑ YES ❑NO ®N/A EQUIPMENT OPERATES PROPERLY ❑ YES ❑ NO ❑N/A KNIGHT FIRE PROTECTION, INC. CERTIFIES THAT ADDITIVES AND CORROSIVE CHEMICALS, SUCH AS SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR STOPPING LEAKS. DRAIN READING OF GAG_T LOCATED NEAR THE RESIDUAL PRESSURE WITH MAIN DRAIN VALVE TEST MAIN DRAIN: G e.r. PSI OPEN WIDE ii0 PSI UNDERGROUND MAINS AND LEAD INS TO THE SYSTEM RISERS WERE FLUSHED BEFORE CONNECTION WAS MADE TO THE ABOVEGROUND SPRINKLER PIPING. VERIFIED BY UNDERGROUND TEST CERTIFICATE ®YES ❑ NO OTHER EXPLAIN FLUSHED BY KNIGHT FIRE PROTECTION 181 YES ❑ NO AP`ROVING • ' ORITY TITLECANS1 .r. . DATE .. • co . o I /, iP� D6/0 s TEST CAPS NUMBED LOCATIONS NUMBS REMOVED WELDED PIPING ®YES ❑NO WELDING IF YES KNIGHT FIRE PROTECTION CERTIFIES THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS B2.1 AND D10.9, LEVEL AR-3 ®YES ❑NO KNIGHT FIRE PROTECTION CERTIFIES THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST YES ❑NO AWS 82.1 AND D10.9, LEVEL AR-3 KNIGHT FIRE PROTECTION CERTIFIES WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED OYES ❑ NO CUTOUTS KNIGHT FIRE PROTECTION CERTIFIES THAT THEY HAVE A CONTROL FEATURE TO ENSURE THAT ALL (DISCS) CUTOUTS (DISCS) ARE RETRIEVED. ®YES ❑ NO HYDRAULIC DATAPLATE PROVIDED IF NO, EXPLAIN DATAPLATE ❑YES ONO DATA PLATE WILL BE PROVIDED BEFORE FINAL INSPECTION. REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: )OCUMENTS DOES THE OWNER HAVE A COPY OF NFPA #25 FOR THEIR REFERENCE. ❑YES ❑NO KNIGHT FIRE PROTECTION, INC. LICENSE/ KNIGHFP044LK kCCEPTANCE EP. TITLE D ■T KNIGH IRE PROTECTION TITLE DATE APP VING AU HO ITY TITLE ,Gpe I w,DA :3-- I ERTIFY AT THE INFORMATION HEREIN IS TRUE AND THAT THIS SPRINKLER SYSTEM WAS RTIFICATION INSTALLED IN ACCORDANCE WITH THE RULES ADOPTED BY THE WASHINGTON ADMINISTRATIVE CODE AS ADMINISTERED BY THE STATE FIRE MARSHAL. WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Lisiecki DAVID LISIECKI 1470-0793-C Level 3 Knight Fire Protection,Inc. N I NAME OF CERTIFICATE OF COMPETENCY HOLDER KNIGHTP044LK� Expia Signature ' 3114 SIGNATURE OF CERTIFICATE OF COMPETENCY HOLDER CERTIFICATE REGISTRATION # 393-07-1470 I+CDTICI!•A Troll CTAT/D HYDROSTATIC: HYDROSTATIC TEST SHALL BE MADE AT NOT LESS THAN 200 PSI FOR TWO HOURS OR 50 PSI ABOVE STATIC PRESSURE IN EXCESS OF 150 PSI FOR TWO HOURS. DIFFERENTIAL DRY-PIPE VALVE CLAPPERS SHALL BE LEFT OPEN DURING TEST TO PREVENT DAMAGE. ALL ABOVEGROUND PIPE TEST LEAKAGE SHALL BE STOPPED. DESCRIPTION PNEUMATIC: ESTABLISH 40 PSI AIR PRESSURE AND MEASURE DROP WHICH SHALL NOT EXCEED 1-1/2 PSI IN 24 HOURS. TEST PRESSURE TANKS AT NORMAL WATER LEVEL AND MEASURE AIR PRESSURE DROP WHICH SHALL NOT EXCEED 1-1/2 PSI IN 24 HOURS. ALL PIPING HYDROSTATICALLY TESTED AT 200 PSI FOR 2 HRS. IF NO, STATE REASON TESTS DRY PIPING PNEUMATICALLY TESTED ❑YES ❑NO N/A EQUIPMENT OPERATES PROPERLY ❑ YES ❑ NO ❑N/A KNIGHT FIRE PROTECTION, INC. CERTIFIES THAT ADDITIVES AND CORROSIVE CHEMICALS, SUCH AS SODIUM SILICATE OR DERIVATIVES OF SODIUM SILICATE, BRINE, OR OTHER CORROSIVE CHEMICALS WERE NOT USED FOR STOPPING LEAKS. DRAIN READING OF GAG LOCATED NEAR THE RESIDUAL PRESSURE WITH MAIN DRAIN VALVE TEST MAIN DRAIN: 4� PSI OPEN WIDE NIA PSI UNDERGROUND MAINS AND LEAD INS TO THE SYSTEM RISERS WERE FLUSHED BEFORE CONNECTION WAS MADE TO THE ABOVEGROUND SPRINKLER PIPING. VERIFIED BY UNDERGROUND TEST CERTIFICATE )SI YES ❑ NO OTHER EXPLAIN FLUSHED BY KNIGHT FIRE PROTECTION ®YES ❑NO AP ROVING U ORITY TITLE CowScr-T,FhA[. DATE .iEFr. CO . L1CD I ivroec D6/d 5 TEST CAPS NUMB ED LOCATIONS NUMB REMOVED WELDED PIPING 1&YES ❑ NO WELDING IF YES KNIGHT FIRE PROTECTION CERTIFIES THAT WELDING PROCEDURES COMPLY WITH THE REQUIREMENTS OF AT LEAST AWS B2.1 AND D10.9, LEVEL AR-3 181 YES ❑NO KNIGHT FIRE PROTECTION CERTIFIES THAT THE WELDING WAS PERFORMED BY WELDERS QUALIFIED IN COMPLIANCE WITH THE REQUIREMENTS OF AT LEAST NI YES ❑NO AWS B2.1 AND D10.9, LEVEL AR-3 KNIGHT FIRE PROTECTION CERTIFIES WELDING WAS CARRIED OUT IN COMPLIANCE WITH A DOCUMENTED QUALITY CONTROL PROCEDURE TO INSURE THAT ALL DISCS ARE RETRIEVED, THAT OPENINGS IN PIPING ARE SMOOTH, THAT SLAG AND OTHER WELDING RESIDUE ARE REMOVED, AND THAT THE INTERNAL DIAMETERS OF PIPING ARE NOT PENETRATED 1g YFS ❑NO CUTOUTS KNIGHT FIRE PROTECTION CERTIFIES THAT THEY HAVE A CONTROL FEATURE TO ENSURE THAT ALL (DISCS) CUTOUTS (DISCS) ARE RETRIEVED. ®YES ❑ NO HYDRAULIC DATAPLATE PROVIDED IF NO, EXPLAIN DATAPLATE ❑ YES El NO DATA PLATE WILL BE PROVIDED BEFORE FINAL INSPECTION. REMARKS DATE LEFT IN SERVICE WITH ALL CONTROL VALVES OPEN: )OCUMENTS DOES THE OWNER HAVE A COPY OF NFPA #25 FOR THEIR REFERENCE. ❑YES ❑NO KNIGHT FIRE PROTECTION, INC. LICENSE/ KNIGHFP044LK kCCEPTANCE EP' TITLE DATE ,5 ce%; I 641,1/fix KNIGH IRE PROTECTION TITLE DAT 'jitc� 4' lam, Life/ I G'Ea//.S- APP VING AU H ITY TITLE,,,,E,,,ec gyp, DATE I Ac D. IBS I ERTIFY AT THE INFORMATION HEREIN IS TRUE AND THAT THIS SPRINKLER SYSTEM WAS RTIFICATION INSTALLED IN ACCORDANCE WITH THE RULES ADOPTED BY THE WASHINGTON ADMINISTRATIVE CODE AS ADMINISTERED BY THE STATE FIRE MARSHAL. WASHINGTON STATE CERTIFICATE OF COMPETENCY FIRE PROTECTION SPRINKLER SYSTEMS David Lisiecki DAVID LISIECKI 1470-0793-C Level 3 Knight Fire Protection,Inc. ry 1 NAME OF CERTIFICATE OF COMPETENCY HOLDER KNIGHTP044L,K� /� --° /`J��///rAv..� '�a-✓I ,y�—;; "� ExpIms i° s�e�m // 42/31/14 SIGNATURE OF CERTIFICATE OF COMPETENCY HOLDER nro Tlnr A Tinki CT AIM CERTIFICATE REGISTRATION # 393-07-1470 KNIGHT FIRE PROTECTION, INC. Jefferson Transit Authority — 9702 LATHROP INDUSTRIAL DRIVE SW KFPJobNo. 14-045 f l OLYMPIA, WA 98512-9188 iI„ (360) 786-8606 MATERIAL & TEST FAX 786-8722 REPORT FOR AI ABOVEGROUND PIPING ON GUARD LICENSE NO. KNIGHFP044LK _24 HOURS A DAY" Procedure upon completion of work: Inspection and tests shall be made by the contractor's representative and witnessed by the AHJ. All defects shall be corrected and system left in service before contractor's personnel finally leave the job. A certificate shall be filled out and signed by both representatives. Copies shall be prepared for approving authorities, owners, and contractor. It is understood the owner's representative's signature in no way prejudices any claim against contractor for faulty moteriol, poor workmanship, or failure to comply with approving authority's requirements or local ordinances. PROPERTY NAME Jefferson Transit Authorit DATE PROPERTY ADDRESS y � ���� 63 Four Corners Road, Port Townsend, WA 98368 SYSTEM LOCATION OR ID REVIEWED AND ACCEPTED BY Jefferson County Fire Marshal• PLANS ADDRESS INSTALLATION CONFORMS TO ACCEPTED PLANS 1 YES ❑ NO EQUIPMENT USED IS APPROVED 14 YES ❑ NO IF NO, EXPLAIN HAS PERSON IN CHARGE OF FIRE EQUIPMENT BEEN INSTRUCTED AS TO )81 YES ❑NO \1STRUCTIONS CARE AND MAINTENANCE OF THE NEW EQUIPMENT AND THE LOCATION OF ALL CONTROL VALVES? HAVE COPIES OF THE FOLLOWING BEEN LEFT ON THE PREMISES: 1. SYSTEM COMPONENT CARE, AND MAINTENANCE INSTRUCTIONS ® YES ❑ NO 2. MAINTENANCE AGREEMENT 18( YES ❑ NO MAKE MODEL S.I.N. YEAR THREAD K—FACT QTY. TEMP. Globe QR SSP GL5601 2012 1/2" 5.6K 51 200' SPRINKLERS Globe QR SSU GL5615 2012 1/2" 5.6K 9 200' Globe QR HSW GL5626 2012 1/2" 5.6K 9 200' Globe OR SSU GL8118 2012 3/4" 8.1K 6 200' Globe SR SSU GL8164 2012 3/4" 8.1K 47 200' Globe QR EC UPRIGHT GL1121 2012 3/4" 11.2K 5 200' Globe DRY QR SSP GL5635 2012 1" 5.6K 1 200' Tyco SR EC HSW TY5332 2012 3/4" 8.0K 3 200' PIPE AND TYPE OF PIPE BLACK STEEL SCHEDULE 40 AND EDDYFLOW PIPE FITTINGS TYPE OF FITTINGS WELDED, CAST/MALLEABLE IRON, GROOVED WATER FLOW INDICATOR INFORMATION MAXIMUM TIME TO OPERATE THROUGH TEST CONNECTION ALARM LOCATION TYPE MAKE MODEL MIN. SEC. DEVICES UTILITY ROOM A138 Vane Potter VSR—S U 3 7 DRY VALVE Q.O.D. MAKE MODEL SERIAL NO. MAKE MODEL SERIAL NO. N/A TIME TO TRIP * TIME WATER ALARM THROUGH TEST WATER AIR TRIP POINT REACHED OPERATED DRY PIPE CONNECTION PRESSURE PRESSURE AIR PRESSURE TEST OUTLET PROPERLY OPERATING MIN. SEC. PSI PSI PSI MIN. SEC. YES NO TEST WITHOUT Q.O.D. WITH Q.O.D. IF NO, EXPLAIN * MEASURED FROM THE TIME THE INSPECTORS TEST CONNECTION IS OPENED (OVER) , ' • Pa!FIRE CHIEF EQUIPMENT 7661 159' PI NE,Redmond WA 98052 P 0 Box 659,Redmond WA 98073 Telephone No.425-641-2127/Fax No.425-562-6662 Jefferson Transit Authority FCE Job # 14-1300 Table of Contents for Equipment Submittals Item Equipment description 1 NFW-100 Addressable FACP 2 FCPS-24S8 Booster Power Supply 3 Indoor and Outdoor Horn/Strobes (P2R, P2RK & PC2R) 4 NP-100 Photo Smoke Detector 5 FDU-80 Remote Annunciator 6 NOT-BG12LX Pull Station 7 D4120 Conventional Duct Detector 8 N100-ISO Iso-Isolation Module 9 NMM-100 & NMM-100P Addressable Modules (same data sheet) 10 NC-100R Relay Module It � MG� 112, X11 I SEP 2 9 2014 JEFFERSON COUNTY DEPT.OF COMMUNITY DEVELOPMENT • DN-60602:A1 FireWarden-100-2(E) Rev 3 , I F I E R , Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3 (NFW2-100)with Version 5.0 firmware is a combination FACP (Fire Alarm Control Panel) and DACT (Digital Alarm Communicator/Transmitter)all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The's quick-remove chassis protects the electronics during con- "."11.i struction. The backbox can be installed allowing field wiring to ¢ i be pulled. When construction is completed,the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS,and increased power for the reset- table and remote sync outputs. o Available accessories include ANN-BUS devices as well as ACS " LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, Remote site or local USB port upload/download, using PS- switched troubles, AC loss, etc.) to a Central Station via the public • Tools. switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four (4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windowse XP or greater, a com- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software . Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal. This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • Remote Acknowledge, Silence, Reset and Drill via address- walktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged • ANN-BUS for connection to following optional modules(cannot directly into the printed circuit board.This permits easy typing of be used if ACS annunciators are used): address labels and other programming information. —N-ANN-80(-W)Remote LCD Annunciator Version 5.0 firmware supports the following: Primary and Sec- ondary —ANN-bus devices,NP-A100,USB port,NAC circuit diag- nostics,a new report has been added to the walk-test that lists —N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone —N-ANN-RLY Relay Module type code for NFV-25/50ZST, Photo Supervisory and auto-reset- —N-ANN-LED Annunciator Module table Drill(non-latching). —N-ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 —ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the ACS&Terminal-mode Annunciators: •Internet saving the monthly cost of two dedicated business tele- phone lines. Although not required, the secondary telephone Up Legacy line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term "FireWarden-100-2" —Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWartlen-100.2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-100E as well. cult board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • • • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lotion is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point • Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: FireWarden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel,one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft. (3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E:Same as NFW2-100, except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NACS): lion. • Four onboard NACs with additional NAC capability using out- 4XTM Reverse Polarity Transmitter Module: Provides super- put control modules (NC-100). The four Class B NACs can aided output for local energy municipal box transmitter, alarm, be converted to four Class A NACs with optional ZNAC-92 and trouble. converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y (Class B) NAC circuits to four(4) Style Z(Class A)cir- • Continuous, March Time, Temporal or California code for cults. main circuit board NACs with two-stage capability. PS Tools: Programming software for Windows®-based PC • Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. • 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE:Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi-flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram (learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than • Continuous fire protection during online programming at the 18AH. front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable;required for printer or for local upload/download program- able on www.magni-fire.com). Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- LED INDICATORS net internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) P.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 • • N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-100R: Addressable relay module containing two isolated N-ANN-RLED: Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-150: Fault Isolator Module. This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: Serial/Parallel Printer Gateway module provides modules in a BB-XP cabinet(optional). Mount up to six modules a connection for a serial or parallel printer.(See DN-7103.) on a CHS-6 chassis in a BB-25. N-ANN-I/O: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R: Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional).Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation. Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-ISO(DN-6994),NP-100 series custom graphic annunciators. (DN-6995), NI-100(DN-6996),NH-100 series(ON-6997),ND-100 series (ON-7006), NP-A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator: 80-char- NOM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558), ACS/ACM Series(ON- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector, manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100:Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.)electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 • . FireWarden-100-2 Rev 3 f•-- Fire Alarm Control/ ANN-BUS Communicator or ANN-BUS DEVICES EIA-485 ► �� N-ANN-80,N-ANN-LED, in ACS mode N-ANN-S/PG,N-ANN-I/O (two wires) •L. : a SMOKE DETECTORS NP-100,NP-100T, 24 VDC NI-100,NP-A100 ► ► I Ir .1 I Optional il M0 01•1 ♦--••• REVERSE M0 ON POLARITY/ HEAT DETECTORS =171 1 CITY BOX NH-100, NH-100R,NH-100H 1 t: OUTPUT —r7 o- ANNUNCIATORS jr 1111111 'r mr.rim (4XTM) ^�0 r 1 . ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS — DUCT DETECTORS NOTE:System can use (optional,order ACM-8R) ND-WO,ND-100R,DNR either ANN-BUS devices OR ACS-mode annunciators. rii, They cannot be used simultaneously. NACs(Notification _�Appliance Circuits) ► BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into the motherboard e . „ . . . lhI ! ! ! 0 0 0 0 0 +�j, e�000 , ADDRE ABLE IP- `� MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They '.El a cannot be used simultaneously. EIA-485 24 VDC ■ 1 T INTERFACE (four wires) r MINI-MONITOR ► Q NMM-100P A OOQOo • FIRE- FDU-80 ■ g Up to 6,000 ft.(1825.8 m) 0 between each FDU-80 in the EIA-485 loop,and between PULL STATION a each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 • • DN-60602:A1•12/07/2010—Page 5 of 6 • • SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring(TR-CE- B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Intelligent Signalling Line Circuits 1 • Addressable device capacity 198 Shipping Specifications • Programmable software zones 99 • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices 16 Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 - AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32—120°F and at a relative humidity 93%±2%RH (non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C ±2°C (90°F±3°F). However, the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH- 18 AH batteries. Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet.Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y (Class B)for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B) or with an optional ZNAC-92 module converts to four —LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z (Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 UL listed)for Style Y(Class B)NAC. Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed com- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Watertlow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps 0 30 VDC (resistive),0.5 amps 0 30 alarm,trouble and supervisory relays may be connected to VAC(resistive).Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettable Power (24 VDC Nomi- _PROPRIETARY (Automatic, Manual, Waterflow and Spnn- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- put.Power-limited. —CENTRAL STATION (Automatic, Manual, Watertlow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. -OT,PSDN(Other Technologies, Packet-switched Data Net- Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC, Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel.In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed:S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®Is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of This document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. Eflilff.Ellfli S MINIIFAC11Nf16 All specifications are subject to change without notice. UUAIITT SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 • • • dn-6927:a FCPS-24S6(C/E) & FCPS- ® 24S8(C/E) N OT I F I E 6- & 8-Amp 24-Volt by Honeywell Remote Power Su• • lies Power Supplies General The FCPS-24S6E (6-amp) and FCPS-24S8E (8-amp) are remote power supplies with battery charger.The FCPS-24S6/- 24S8 may be connected to any 12 or 24 volt fire alarm control panel (FACP) or may be used as stand-alone supplies. Pri- mary applications include notification appliance (bell) circuit (NAC)expansion(to support ADA requirements and NAC syn- chronization) or auxiliary power to support 24 volt system accessories. The FCPS-24S6/-24S8 provides regulated and filtered 24 VDC power to tour notification appliance circuits 0 configured as either four Class B(Style Y)or Class A(Style Z, with ZNAC-4 option module).Alternately,the four outputs may be configured as all non-resettable, all resettable or two non- resettable and two resettable. The FCPS-24S6/-24S8 also contains a battery charger capable of charging up to 18 AH batteries. FCPS-24S6C&FCPS-24S8C are ULC-listed. NOTE: Unless otherwise specified, the terms FCPS-24S6 and FCPS-24S8 used in this document refers to the standard FCPS- 24S6 and FCPS-24S8, FCPS-24S6C and FCPS-24S8C, the FCPS-24S6E and FCPS-24S8E ' P 1PF Features • Includes integral battery charger capable of charging up to • UL-Listed NAC synchronization using System Sensor, 18 AH batteries.Cabinet capable of housing 7.0 AH batter- Wheelock,or Gentex"Commander2"appliances. ies. • Operates as a "sync-follower" or as a "sync-generator" • Battery charger may be disabled via DIP switch for applica- (default). See note on page 2. tions requiring larger batteries. • Contains two fully-isolated input/control circuits -triggered • Fixed, clamp-type terminal blocks accommodate up to 12 from FACP NAC (NAC expander mode)or jumped perma- AWG(3.1mm2)wire. nently"ON"(stand-alone mode). • Four Class B (Style Y) or four Class A (Style Z, with Specifications ZNAC-4 module)NACs. Primary(AC)Power: • 6-amp (FCPS-24S6) or 8-amp (FCPS-24S8) full load out- • FCPS-24S6C/-24S8C: 120 VAC,60 Hz,3.2A maximum. put, with 3 amps maximum/circuit, in NAC expander mode (UL 864). • FCPS-24S6E/-24S8E: 240 VAC,50 Hz, 1.6A maximum. • 4-amp (FCPS-24S6) or 6-amp (FCPS-24S8) continuous • Wire Size: minimum#14 AWG(2.0mm2)with 600 V insula- output in stand-alone mode(UL 1481). tion. • Compatible with coded inputs; signals passed through. Control Input Circuit: • Optional power-supervision relay(EOLR-1). • Trigger Input Voltage: 9 to 32 VDC. • In stand-alone mode, output power circuits may be config- • Trigger Current: 2.0 mA(16-32 V); Per Input: 1.0 mA(9 ured as: resettable, (reset line from FACP required), -16 V). non-resettable,or a mix of two and two. Trouble Contact Rating: 5 A at 24 VDC. • Fully regulated and filtered power output-optimal for pow- Auxiliary Power Output: Specific application power 500 mA ering four-wire smoke detectors, annunciators, and other maximum. system peripherals requiring regulated/filtered power. • Power-limiting technology meets UL power-limiting require- Output Circuits: ments. • +24 VDC filtered,regulated. • Form-C normally-closed trouble relay. • 3.0 A maximum for any one circuit. • Fully supervised power supply,battery,and NACs. • Total continuous current for all outputs(stand-alone mode): • Selectable earth fault detection. —FCPS-24S6: 4.0 A maximum. • AC trouble report selectable for immediate 2-hour delay. —FCPS-24S8: 6.0 A maximum. • Works with virtually any UL 864 fire alarm control which uti- • Total short-term current for all outputs(NAC expander mode): lizes an industry-standard reverse-polarity notification cir- —FCPS-24S6: 6.0 A maximum. cuit(including unfiltered and unregulated bell power). —FCPS-24S8: 8.0 A maximum. • Requires input trigger voltage of 9-32 VDC. Secondary Power(Battery)Charging Circuit: • Self-contained in compact, locking cabinet- 15'H x 14.5W x 2.75"D(cm:38.1H x 36.83W x 6.985D). • Supports lead-acid batteries only. • Float-charge voltage: 27.6 VDC. dn-6927:a•04/30/09—Page 1 of 2 • i • Maximum current charge: 1.5 A. Standards and Codes • Maximum battery capacity: 18 AH. The FCPS-24S6 and FCPS-24S8 comply with the following standards: Applications • NFPA 72 National Fire Alarm Code. Example 1: Expand notification appliance power an additional • UL 864 Standard for Control Units for Fire Alarm Systems 6.0 A (FCPS-24S6) or 8.0 A (FCPS-24S8). Use up to four (NAC expander mode). Class B (Style Y) outputs or four Class A (Style Z) outputs UL 1481 Power Supplies for Fire Alarm Systems. •(using ZNAC-4). For example,the FACP notification appliance circuits will activate the FCPS when reverse-polarity activation • occurs. Trouble conditions on the FCPS are sensed by the Agency Listings and Approvals FACP through the notification appliance circuit. These listings and approvals apply to the modules specified in Example 2: Use the FCPS to expand auxiliary regulated 24- this document. In some cases,certain modules or applications volt system power up to 4.0 A (FCPS-24S6) or up to 6.0 A may not be listed by certain approval agencies, or listing may (FCPS-24S8). Both resettable and non-resettable power be in process.Consult factory for latest listing status. options are available. Resettable outputs are created by con- • UL Listed: S635,5674 necting the resettable output from the FACP to one or both of ULC Listed:S635(PCPs-24S6C&FCPS-24S8C) •the FCPS inputs. • Example 3: Use addressable control modules to activate the CSFM Approved: 7315-0028:225 FCPS instead of activating it through the FACP notification • MEA: 299-02-E appliance circuits.This typically allows for mounting the FCPS • FM Approved at greater distances` away from the FACP while expanding system architecture in various applications. Ordering Information For example, an addressable control module is used to acti- FCPS-24S6: 6.0 A, 120 VAC remote charger power supply. vate the FCPS,and an addressable monitor module is used to Includes main printed circuit board, transformers, enclosure sense FCPS trouble conditions. Local auxiliary power output (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and from the FCPS provides power to the addressable control installation instructions. module. FCPS-24S6C: Same as above,ULC-listed. "NOTE:Addressable FACPs are capable of locating control and monitor modules at distances of up to 12,500 feet(3,810 meters). FCPS-24S6R: Same as FCPS-24S6 with red enclosure. FCPS-24S6E: 6.0 A, 240 VAC remote charger power supply. Sync Follower/Generator Note Includes main printed circuit board, transformers, enclosure In some installations, it is necessary to synchronize the flash (15"H x 14.5"W x 2.75"D[cm:38.1 H x 36.83W x 6.985D]),and timing of all strobes in the system for ADA compliance. installation instructions. Strobes accomplish this by monitoring very short timing pulses FCPS-24S8: 8.0 A, 120 VAC remote charger power supply. on the NAC power which are created by the FACP. When Includes main printed circuit board, transformers, enclosure installed at the end of a NAC wire run,the FCPS-24S6/-24S8 (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and can track (i.e. ''follow") the strobe synchronization timing installation instructions. pulses on the existing NAC wire run.This maintains the overall FCPS-24S8C Same as above, ULC-listed. system flash timing of the additional strobes attaches to the FCPS. FCPS-24S8R: Same as FCPS-24S8 with red enclosure. When the FCPS-24S6/-24S8 is configured(via DIP switch set- FCPS-24S8E: 8.0 A, 240 VAC remote charger power supply. tings)as a"sync follower,"the FCPS's NAC outputs track the Includes main printed circuit board, transformers, enclosure strobe synchronization pulses present at the FCPS's sync (15"H x 14.5"W x 2.75"D[cm:38.1H x 36.83W x 6.985D]),and input terminal.The pulses originate from an upstream FACP or installation instructions. other power supply. ZNAC-4: Class A(Style Y)NAC option module. When the FCPS-24S6/-2458 are configured (via DIP switch EOLR-1: 12/24 VDC end-of-line relay for monitoring four-wire settings) as a "sync generator," the FCPS's sync input termi- smoke detector power. nals are not used. Rather, the FCPS is the originator of the BAT-1270: Battery, 12-volt, 7.0 AH (two required, see BAT strobe synchronization pulses on the FCPS's NAC outputs. In Series data sheet DN-6933). "sync generator'mode,the sync type (System Sensor,Whee- lock,or Gentex)is selectable via DIP switch settings. PS-1270: Battery, 12-volt, 7.0 AH (two required, see PS Series data sheet DN-1109) System Sensor®and NOTIFIEH®are registered trademarks of Honeywell International Inc. 02009 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 900+1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. _ A SWAMIES All specifications are subject to change without notice. 'MITT ATiTEYA Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notilier.com Page 2 of 2—dn-6927:a•04/30/09 • • DN-7087:C1 SpectrAlert® Advance OT 1 F 1 E R® Selectable Output Notification Appliances by Honeywell Audio/Visual Devices �:, W.Q.L 3..m ,St: 6 General System Sensor® SpectrAlert® Advance selectable-output horns,strobes and horn/strobes are rich with features guaran- `.*g teed to cut installation times and maximize profits.The Spec- •(„ a trAlert Advance series of notification appliances is designed to „, , 41% e E simplify your installations, with features such as: plug-in ^ designs,instant feedback messages to ensure correct installa- Indoor Ceiling Outdoor Ceiling tion of individual devices, and eleven field-selectable candela HornlStrobe Strobe settings for wall and ceiling strobes and horn/strobes. More specifically, when installing Advance products, first ” ; . attach a universal mounting plate to a four-inch square, four- -' inch octagon, or double-gang junction box. The two-wire p';wiz - $ mounting plate attaches to a single-gang junction box. E ':' Then, connect the notification appliance circuit wiring to the --"' $ SEMS terminals on the mounting plate. Indoor Wall Indoor Ceiling Finally,attach the horn,strobe,or horn/strobe to the mounting Horn/Strobe Strobe plate by Inserting the products tabs in the mounting plate's grooves. The device will rotate into position, locking the prod- ucts pins into the mounting plate's terminals. The device will L-=temporarily hold in place with a catch until it is secured with a a. ; .1::captured mounting screw, € SpectrAlert Advance products allow you to choose: • 12 or 24 volts. Indoor Wall Outdoor Wall • 15, 15/75,30,75, 95, 110, 115, 135, 150, 177,or 185 can- Horn Hog 1.4 Strobe dela by way of a rear-mounted slide switch and front view- • Outdoor products rated from-40°F and 151°F (-40°C and ing window. 66°C). • Horn tones and volume by way of a rotary switch. • Outdoor products rainproof per UL50 (NEMA 3R) and • The SpectrAlert Advance series includes outdoor notifica- weatherproof per NEMA 4X, IP56 tion appliances. Outdoor strobes and horn/strobes (two- • Minimal intrusion into the backbox. wire and four-wire)are available for wall or ceiling.Outdoor • Horn rated at 88+dbA at 16 volts. horns are available for wall only.All System Sensor outdoor • Rotary switch for tone selection. products are rated between-40°F and 151°F (-40°C and Three horn volume settings. 66°C)in wet or dry applications. 9 Models available: • Electrically compatible with existing SpectrAlert products. • Indoor wall-mount: horn, strobe, 2-wire horn/strobe, 4-wire Engineering Specifications horn/strobe. • Indoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire SpectrAlert Advance horns, strobes, and horn/strobes shall horn/strobe. mount to a standard 4.0' x 4.0' x 1.5' (10.16 x 10.16 x 3.81 • Outdoor wall-mount: horn, strobe, 2-wire horn/strobe, 4• cm)backbox,4.0'(10.16 cm)octagonal backbox,or a double- wire horn/strobe. gang backbox.Two-wire products shall also mount to a single- gang 2.0•x 4.0'x 1.875'(5.08 x 10.16 x 4.763 cm)backbox.A • Outdoor ceiling-mount: strobe, 2-wire horn/strobe, 4-wire universal mounting plate shall be used for mounting ceiling horn/strobe. and wall products. The notification appliance circuit wiring shall terminate at the universal mounting plate. Also, Spec- Features trAlert Advance products, when used with the Sync•CircuiP" Module accessory, shall be powered from a non-coded notif i- • Plug-in design. cation appliance circuit output and shall operate on a nominal • Same mounting plate for wall-and ceiling-mount units. 12 or 24 volts. When used with the Sync•Circuit Module, 12- • Shorting spring on mounting plate for continuity check volt rated notification appliance circuit outputs shall operate before installation. between 9 and 17.5 volts; 24-volt rated notification appliance • Captive mounting screw. circuit outputs shall operate between 17 and 33 volts. Indoor • Tamper-resistance capability. SpectrAlert Advance products shall operate between 32°F and 120°F(0°C and 49°C)from a regulated DC, or full-wave-recti- • Field-selectable candela settings on wall and ceiling units: lied, unfiltered power supply. Strobes and horn/strobes shall 15, 15/75,30,75,95, 110, 115, 135, 150, 177, 185. have field-selectable candela settings including 15, 15/75,30, • Automatic selection of 12 or 24 volt operation at 15 and 15/ 75,95, 110, 115, 135, 150, 177, 185. 75 candela. • Outdoor wall and ceiling products. DN-7087:C1•11/9/11—Page 1 of4 • • STROBE Operating Specifications The strobe shall be a System Sensor SpectrAlert Advance • Standard operating temperature: 32°F to 120°F (0°C to Model listed to UL 1971 and shall be approved for fire 49°C) protective service.The strobe shall be wired as a primary-sig- K Series operating temperature: -40°F to 151°F (-40°C •naling notification appliance and comply with the Americans to 66°C). with Disabilities Act requirements for visible signaling appli- ances, flashing at 1 Hz over the strobe's entire operating volt- • Humidity range: 10% to 93% non-condensing (indoor age range.The strobe light shall consist of a xenon flash tube products). - and associated lens/reflector system. • Strobe flash rate: 1 flash per second, HORN/STROBE COMBINATION • Nominal voltage: regulated 12 VDC/FWR or regulated 24 VDC/FWR. NOTE: Full Wave Rectified(FWR) voltage is a The horn/strobe shall be a System Sensor SpectrAlert non-regulated, time-varying power source that is used on Advance Model listed to UL 1971 and UL 464 and some power supply and panel outputs. shall be approved for fire protective service, The horn/strobe Operating voltage range:8 V to 17.5 V(12 V nominal);or •shall be wired as a primary-signaling notification appliance 16 V to 33 V(24 V nominal). NOTE:P, S,PC,and SC prod- and comply with the Americans with Disabilities Act require- ucts will operate at 12 V nominal only for 15 cd and 15/75 ments for visible signaling appliances,flashing at 1 Hz over the strobe's entire operating voltage range. The strobe light shall cd. consist of a xenon flash tube and associated lens/reflector sys- • input terminal wire gauge: 12 to 18 AWG (3.31 to 0.821 tern.The horn shall have three audibility options and an option mm2), to switch between a Temporal 3 pattern and a Non-Temporal • Ceiling-mount dimensions(including lens): 6.8' diame- (continuous)pattern.These options are set by a multiple posi- ter x 2.5"deep(17.3 cm diameter x 6.4 cm deep). tion switch.On four-wire products,the strobe shall be powered • Wall-mount dimensions(including lens):5.6'H x 4.7'W independently of the sounder.The horn on horn/strobe models x 2.5'D(14.2 cm H x 11.9 cm W x 6.4 cm D). shall operate on a coded or non-coded power supply. • Horn dimensions: 5.6" H x 4.7"W x 1.3' D (14.2 cm H x OUTDOOR PRODUCTS 11.9 cm W x 3.3 cm D). SpectrAlert Advance outdoor horns.strobes and horn/strobes shall be listed for outdoor use by UL and shall operate Agency Listings and Approvals between -40°F and 151°F (-40°C and 66°C). The products The listings and approvals below apply to SpectrAlert Advance shall be listed for use with a System Sensor outdoor/weather- Selectable Output Notification Devices. In some cases,certain proof backbox with halt-inch and three-fourths-inch conduit modules may not be listed by certain approval agencies, or entries, listing may be in process. Consult factory for latest listing sta- SYNCHRONIZATION MODULE tus The module shall be a System Sensor Syn •Circuit MDL3R or • UL Listed: S4011 (HR_, HW_, P2_, P4_, PC2_, MDL3W listed to UL 464 and shalt be approved for tire protec- PC4_ models); S5512 (models SCR, SCRH, SCW, five service.The module shall synchronize SpectrAlert strobes SCWH, SR, SRH, SW, SWH); S3593 (SCRHK, SCRK, at 1 Hz and horns at Temporal 3. Also, while operating the SRHK,SRK). strobes, the module shall silence the horns on horn/strobe • ULC Listed: S4011 (HRA, HRKA); S5512 (typically "A" models over a single pair of wires.The module shall mount to models, with exception of outdoor strobes). See Canadian a 4.688' x 4.688'x 2.125'(11.906 x 11.906 x 5.398 cm)back- data sheet for listings and specifications. box. The module shall also control two Style Y (class B) cir- • FM approved cults or one Style Z (Class A) circuit. The module shall MEA:452-05-E synchronize multiple zones. Daisy-chaining two or more syn- chronization modules together will synchronize all the zones • CSFM: 7125-1653:0186 (SCR, SCRH, SCW, SCWH, SR, they control. The module shall not operate on a coded power SRH,SW, SWH);7300-1653:0188(P2_, P4_,PC2_, PC4_ supply. modules); 7135-1653:0189 (HR, HRK, HW); 7300- 1653:0187 (SCRHK,SCRK,SRHK,SRK). Strobe Current Draw, Horn Current Draw, UL Maximum (mA RMS) UL Maximum (mA RMS) 8-17.5V 16-33V Sound 8-17.5V 16-33V Candela Pattern dB DC FWR DC FWR DC FWR DC FWR 15 123 128 66 71 Temporal High 57 55 69 75 15/75 142 148 77 81 Temporal Medium 44 49 58 69 Standard 30 NA N/A 94 96 Temporal Low 38 44 44 48 Candela 75 NA NA 158 153 Non-temporal High 57 56 69 75 Range 95 NA NA 181 176 Non-temporal Medium 42 50 60 69 110 NA NA 202 195 Non-temporal Low 41 44 50 50 115 NA NA 210 205 Coded High 57 55 69 75 135 NA NA 228 207 Coded Medium 44 51 56 69 High 150 NA NA 246 220 Coded Low 40 46 52 50 Candela 177 NA NA 281 251 Range 185 NA NA 286 258 Page 2 of 4—DN-7087:C1•11/9/11 .„ • • Horn and Horn/Strobe Horn and Horn/Strobe Output (dBA) Rotary Switch Setting 8-17.5V 16-33 V Setting Repetition Rate dB Level Switch Sound dB Position Pattern DC FW DC FW 1 Temporal horn High R R 2 Temporal horn Medium 1 Temporal High 78 '78 84 84 3 Temporal horn Low 2 Temporal Medium 74 74 80 80 4 Normal horn High 3 Temporal Low 71 73 76 76 5 Normal horn Medium 4 • Non-temporal High 82 82 88 88 6 Normal horn Low 5 Non-temporal Medium 78 78 85 85 7' Externally coded High 6 Non-temporal Low 75 75 81 81 8' Externally coded Medium 7' Coded High 82 82 98 88 9' Externally coded Low 8' Coded Medium 78 78 85 85 `NOTE:Settings 7, 8,and 9 are not available 9' Coded Low 75 75 81 81 on 2-wire hom/strobe. 'NOTE:Settings 7, 8, and 9 are not available on 2-wire hom/strobe. Two-Wire Horn/Strobe, STANDARDCandela Range (15 - 115 cd), UL Maximum Current Draw (mA RMS) Input,Sound Pattern,dB 8-17.5 V 16-33 V Level 15 15175 15 15/75 30 75 95 110 115 DC Input,Temporal.High 137 147 79 90 107 176 194 212 218 DC Input,Temporal,Medium 132 144 69 80 97 157 182 201 210 DC Input,Temporal,Low 132 143 66 77 '93 154 ' 179 198 207 DC Input,Non-temporal,High 141 152 91 100 116 176 201 221 229 DC Input,Non-temporal,Medium 133 145 75 85 102 163 187 207 216 DC Input,Non-temporal,Low 131 144 68 79 96 156 182 201 210 FWR Input,Temporal,High 136 155 88 ' 97 112 168 190 210 218 FWR Input,Temporal,Medium 129 152 78 88 103 160 184 202 !.206 FWR Input,Temporal,Low 129 151 76 86 101 160 184 194 201 FWR Input,Non-temporal,High 142 161 103 112 126 181 203 221 229 FWR Input,Non-temporal,Medium 134 155 85 95 110 166 189 208 '216 FWR Input,Non-temporal,Low 132 154 80 90 105 161 184 '202 211 Two-Wire Horn/Strobe, HIGH Candela Range (135 - 185 cd), UL Maximum Current Draw (mA RMS) 16-33V 16-33V DC Input FWR Input 135 150 177 185 135 150 177 185 DC,Temporal,High 245 259 290 297 FWR,Temporal, High 215 231 '258 265 DC,Temporal,Medium 235 253 288 297 FWR,Temporal,Medium 209 224 250 258 DC,Temporal,Low 232 251 282 292 FWR,Temporal, Low 207 221 248 256 DC,Non-temporal,High ' 255 270 303 309 FWR,Non-temporal, High 233 248 275 281 DC,Non-temporal.Medium 242 259 293 299 FWR,Non-temporal, Medium 219 232 262 267 DC,Non-temporal,Low 238 254 291 295 FWR,Non-temporal, Low 214 229 256 262 70876m1200D.41 4.7" ; 6.8' I. pp� 2s /ft ) ' 1 - 2.5" • DN-7087[x1•11/9/11—Page 3 of 4 • Ordering Information Model Description Model Description WALL HORN/STROBES CEILING HORN/STROBES P2R 2-wire hornlstrobe,standard cd,red. PC2R 2-wire horn/strobe,standard cd,red. P2RH 2-wire hornlstrobe,high cd,red. PC2RH 2-wire hom/strobe,high cd,red. P2RK 2-wire hom/strobe,standard cd,red,outdoor. PC2RK 2-wire horn/strobe,standard cd,red,outdoor. P2RHK 2-wire horn/strobe,high cd,red,outdoor. PC2RHK 2-wire horrdstrobe,high cd,red,outdoor. P2W 2-wire horn/strobe,standard cd,white. PC2W 2-wire horn/strobe,standard cd,white. P2WH 2-wire horn/strobe,high cd,white. PC2WH 2-wire horn/strobe,high cd,while. P4R 4-wire hom/strobe,standard cd,red. PC4R 4-wire horn/strobe,standard cd,red. P4RH 4-wire hom/strobe,high cd,red. PC4RH 4-wire horn/strobe,high cd,red. P4RK 4-wire hom/strobe,standard cd,red,outdoor. PC4RK 4-wire horn/strobe,standard cd,red,outdoor. P4RHK 4-wire horn/strobe,high cd,red,outdoor. PC4RHK 4-wire horn/strobe,high cd,red,outdoor. P4W 4-wire horn/strobe,standard cd,white. PC4W 4-wire hom/strobe,standard cd,white. P4WH 4-wire hom/strobe,high cd,white. PC4WH 4-wire horn/strobe,high cd,white. WALL STROBES CEILING STROBES SR Strobe,standard cd,red. SCR Strobe,standard cd,red. SRH Strobe,high cd,red. SCRH Strobe,high cd,red. SRK Strobe,standard cd,red,outdoor. SCRK Strobe,standard cd,red,outdoor. SRHK Strobe,high cd,red,outdoor. SCRHK Strobe,high cd,red,outdoor. SW Strobe,standard cd,white. SCW Strobe,standard cd,white. SWH Strobe,high cd,white. SCWH Strobe,high cd,white. ACCESSORIES HORNS BBS-2A Backbox skirt,wall,red. HR Horn,red. BBSW-2A Backbox skirl,wall,white. HRK Horn,red,outdoor. BBSC-ZA Backbox skid,ceiling,red. HW Horn,white. BBSCW-2A Backbox skirl,ceiling,white. ACCESSORIES,continued SA-WBB Weatherproof backbox,wall. TR-HS Trim Ring,wall,red,package of 5 SA-WBBC Weatherproof backbox,ceiling. TRW-HS Trim Ring,wall,white,package of 5 WTP Weatherproof,flush mount plate,red TRC-HS Trim Ring,ceiling,red,package of 5 WTPW Weatherproof,flush mount plate,white TRCW-HS Trim Ring,ceiling,while,package of 5 NOTE: "High cd"refers to strobes that include 195, 150, 177, and 185 candela settings. "Standard cd"refers to strobes that include 15, 15/75,30, 75,95, 110,and 115 candela settings. NOTE: For strobes and horn/strobes,add suffix"F"for French or"B"for Bilingual. NOTE: All outdoor models("K(A)"suffix)include a plastic weatherproof backbox. NOTE: Add"-R"to models for weatherproof replacement device (no back box included). Only for use with weatherproof outdoor flush mounting plate, WTP and WTPW. NOTE: Add"P"to model for plain housing. (No"FIRE"marking on cover.) Sync•Circult" is a trademark and NOTIFIER® and SpectrAlert® are registered trademarks of Honeywell International Inc. 02011 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. we ' V O I I I J This document is not intended to be used for installation purposes. I1 We try to keep our product information up-to-date and accurate. G E R T I r r r u We cannot cover all specific applications or anticipate all requirements. HERB II INNIPMEli All specifications are subject to change without notice. I011tITY STSHTIS For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. wwwnotifier.com Page 4 al 4—DN-7087:C1•1119/11 • DN-6995:C•A1-320 NP-1 00(A) Series NOT 1 F 1 E R® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACP5). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local,visible sensor indication.Remote LED annunciator capa- bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A)in B210LP(A) Base DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability, especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often Addressing better than photoelectric detectors at sensing fast, flaming 9 fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP-25,and 01 –50 with FireWarden-50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A)series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple base to simplify installation,service and maintenance, field cleaning. Mount base(all base types)on an electrical backbox which is Operation at least 1.5"(3.81 cm)deep. For a chart of compatible junction boxes,see DN-60054. • Withstands air velocities up to 4,000 feet-per-minute(20 m/ sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC • Factory preset at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring 'T-taps° or branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level, mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed(communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single-gang box, 3.5' (8.89 cm) or 4.0' (10.16 cuit (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0"(10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient pro- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar sham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a Options more stable detector. • Remote LED output connection, PN RA100Z(A). ON-6995:C•12/07/2011—Page 1 of 2 • • Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use with a DNRA duct detector housing; B210LPA base included. Each detector can have its sensitivity tested (required per NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar- NO7E:"A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range: 15-32 VDC(peak). B210LPBP:Bulk pack of B210LP;package contains 10. Standby current:300 jtA OJ 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA 0 24 VDC(latched"ON"). B501 BP:Bulk pack of B501;package contains 10. Air velocity:4,000 ff./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1'(5.33 cm)high; base determines diameter. Replaces B501 BH series bases in retrofit applications. -B210LP(A):6.1"(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1' (10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2). Relay type:Form-C.Rating:2.0 -B200SR(A):6.875'(17.46 cm)diameter. A 0 30 VDC resistive; 0.3 A 0 110 VDC inductive; 1.0 A 0 -B224RB(A):6.2'(15.748 cm)diameter. 30 VDC inductive. Weight:3.6 oz. (102 g). B224BI(A): Plug-in System Sensor isolator detector base. Maximum 25 devices between isolator bases (see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F); for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C-49°C(32°F-120°F) low-profile. Relative humidity: 10%-93%,non-condensing. F110BP: Bulk pack of Fl 10; package contains 15. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3-32 VDC. Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600: Surface mounting kit listing may be in process. Consult factory for latest listing sta- M02-04-00:Test magnet. tus. UL Listed:S7115. M02-09-00:Test magnet with telescoping handle. •• ULC Listed:5911. XR2B: Detector removal tool. Allows installation and/or CSFM:7272-0028:0231. removal of detector heads from bases in high ceiling applica- • tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot(1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010:Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:A"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B210LP base only;box of 10. included. NP-100A: Sames as NP-100 with ULC Listing; B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-10OT with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International Inc. B210LP base included. ®2011. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 901 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. c E a r F r E o We cannot cover all specific applications or anticipate all requirements. 6ICIr&6ilN111 MNtNA<IMEC All specifications are subject to change without notice. EUAIITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:C•12/07/2011 s s DN-6820:B•D-123 FDU-80 ® NOTIFIER 80 Character Liquid Crystal Display by Honeywell Annunciators General The FDU-80 is a compact,cost-effective, 80-character,backlit LCD remote Fire Annunciator for use with the NOTIFIER Fire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels(FACPs).The FDU-80 mimics the display of the control panel and displays complete system point status information. „p• ,w„vl,gy .tee Up to 32 FDU-80s may be connected onto the EIA-485 termi- - '` _ nal port of each FACP.The FDU-80 requires no programming, _ which saves time during system commissioning. =—_ Features ) • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, '-- Drill and Reset with enable key. 613201M8 iP9 • System status LEDs for Power,Alarm,Trouble,Supervisory and Alarm Silenced. • No programming necessary—FDU-80 connects to the ter- Ordering Information minal porton the FACP. FDU-80:80 character,backlit,LCD Fire Annunciator with con- • Displays device type identifiers, individual point alarm,trou- trol switches for remote control of system functions, and key- ble or supervisory,zone and custom alpha labels. switch lock. • Time-and-date display field. FDU-80C: ULC-listed version;see DN-60573 for details. • Aesthetically pleasing design. 10103:Three-gang electrical box,minimum 2.188"(5.556 cm) • May be powered from the host FACP or by remote power deep,for semi-flush mount applications. supply(requires 24 VDC). SBB-3: Three-gang surface backbox for surface-mount appli- • Up to 32 FDU-80 annunciators per FACP. cations. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m) from Agency Listings And Approvals the FACP. These listings and approvals apply to the modules specified in • Local piezo sounder with alarm and trouble resound. this document. In some cases,certain modules or applications • Semi-flush mounts to 2.188" (5.556 cm) minimum deep, may not be listed by certain approval agencies, or listing may three-gang electrical box (NOTIFIER PN 10103) or three- be in process.Consult factory for latest listing status. gangable electrical switchbox. • UL Listed: S635 • Surface-mounts to NOTIFIER PN SBB-3 surface backbox. • MEA Listed:245-00-E Operation • FDNY: COA#6038• CSFM:7120-0028:209 The FDU-80 annunciator provides the FACP with point annun- • FM Approved ciation with full display text on an 80-character LCD display. NOTE:For ULC-listed version,see DN-60573. The FDU-80 also provides an array of LEDs to indicate system status,and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:8.05/17/2010—Page 1 of 2 • • NOTIFIER®is a registered trademark of Honeywell International Inc. ©2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. r V O 90 1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F E O We cannot cover all specific applications or anticipate all requirements. @l lMFIlNR N fAMIFALTIRIN6 All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6620:8•05/17/2010 • • DN-7001:D•A1.380 NOT-BG 12LX N OT I F I E R® Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT-BG12LX is a state-of-the-art, dual-action FIRE (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. `` PUSH IN Features *PULL 1, • Maintenance personnel can open station for inspection and 1 address setting without causing an alarm condition. • Built-in bicolor LED, which is visible through the handle of the station, flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. ^ Z s • Captive screw terminals wire-ready for easy connection to \ NOTIF{ER t SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi- flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4' • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in, then pulling down on the handle causes it to latch in the down/activated position.Once latched, the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight: 9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current: 5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that atter actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi-flush into a single-gang, ing instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches • box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi-flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single-gang, double gang, or 4'(10.16 cm) square electrical box, and shall be installed ON-7001:D•4/13/2012—Page 1 of 2 • • • within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with Iwo wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT-BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) - SB-10: Surface backbox;metal. SE-I/O:Surface backbox;plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Iso 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. _ c 81011811118111188811111111 1181 r r r 11 All specifications are subject to change without notice. ti SYY5TEN$ Made In the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:0.4/13/2012 • DN-60424 81 InnovairFlex * NOTIFIEW Conventional Duct Smoke Detectors - by Honeywell Conventional Initiating Devices General The Notifier InnovairFlex photoelectric smoke detector fea- tures a pivoting housing that fits various applications: both square and rectangular footprints mount to round or rectangu- lar --- _, duct work. This new duct smoke detector senses airflow speeds ranging from 100 to 4,000 feet per minute with proven precision.The i\ enhancements built into this model improve false alarm immu nity(with plug-in sensor head);broaden operating temperature (-4°F to 158°F, -17°C to 70°C) and humidity(0 to 95 percent 1 g non condensing) ranges; while simplifying installation and e maintenance.These advance features can detect smoke even in the harshest duct applications. The new design provides more wiring space with an added 3/4 inch conduit knockout. Numbers and labels for terminal desig- nations are consistent with previous Innovair models.The new sampling tube can be clicked into position with one smooth WARNING: Duct smoke detectors have motion from either the front or the back of the detector. specific limitations. The Notifier InnovairFlex duct smoke detector has signals to Duct Smoke Detectors are: indicate trouble and maintenance conditions. Additionally, a • NOT a substitute for an open area smoke cover tamper feature is incorporated to indicate a trouble con- detector diticn when the sensor cover is removed or improperly •NOT a substitute for early warning detection,and installed. An improved cover design, with an integrated low- • NOT a replacement for a building's regular fire flow feature, isolates the sensor head from the low-flow tech- detection system. nology for simple maintenance. The Notifier InnovairFlex series is designed for greater flexibil- ity and reliable smoke detection to simplify installation and maintenance. The new InnovairFlex product line is backward Specifications compatible to existing Innovair models, including remote test Size: (Rectangle) 14.38 in (37 cm) Length; 5 in (12.7 cm) accessories. Width,2.5 in(6.36 cm)Depth. Features Size:(Square)7.75 in(19.7 cm)Length;9 in(22.9 cm)Width; 2.5 in(6.35 cm) Depth. • Photoelectric,Integrated low-flow technology. Weight: 1.8 lb(0.82 kg). • Air velocity rating from 100 ft/min to 4,000 ft/min(0.5 m/s to 20.32 m/sec). Operating Temperature Range: (-4°F to 158°F, -17°C to • Versatile mounting options in square or rectangular configu- 70°C). ration with modular construction. Storage Temperature Range: -22°F to 158°F (-30°C to • Plug-in sensor. 70°C). • Superb false alarm immunity with the latest sensor technol- Operating Humidity Range: 0% to 95% relative humidity ogy. (non-condensing). • Broader ranges for operating temperature (-4°F to 158°F, Air Duct Velocity: 100 to 4,000 ft/min(0.5 to 20.32 m/s). -17°C to 70°C)and humidity(0%to 95%non-condensing). ELECTRICAL RATINGS • Patented sampling tube installs from front or back of the detector with no tools required. Power supply voltage:8.5-35 VDC. • A cover tamper feature to indicate a trouble condition for Input capacitance:0.1uF max. removed or improperly installed sensor cover. Reset voltage:2.5 VDC min. • Increased wiring space with a newly added 3/4" conduit Reset time(with RTS151):0.03 to 0.3 seconds. knockout. • Improved LED status. Reset time(by power down):0.3 seconds max. • 24 VDC. Power up time:35 seconds max. • Backward compatibility with existing Innovair products, Alarm response time: 15 seconds. including remote accessories. Current Requirements:(Using No Accessories) —Peak standby current: 120uA. —Max standby current:60uA(average). —Max alarm current: 130mA. DN-60424:B1•10/5/2011 —Page 1 of 2 • ACCESSORY CURRENT LOADS AT 24 VDC terns. The flexible housing of the duct smoke detector fits both square and rectangular footprints. The detector shall operate at air velociites of 100 ft/min to 4,000 ft/min(0.5 m/sec to 20/32 m/ Device Standby Alarm sec). The unit shall be capable of providing a trouble signal in RA100Z OmA 12 mA Max the event that the sensor cover is removed or improperly installed. It shall be capable of local testing via magnetic switch RTS151 OmA 12mA Max or remote testing using the RTS151KEY remote test station. Terminal connections shall be of the strip and clamp method RTS151KEY 12mA 12mA Max suitable for 12-18 AWG wiring. Agency Listings and Approvals Product Line Information Consult product manual for lists of compatible UL-Listed D2: InnovairFlex duct detector, includes 2-wire photo electric devices. In some cases, certain modules may not be listed by low-flow duct smoke detector. certain approval agencies, or listing may be in process. Con- D4120: InnovairFlex duct detector,includes 4-wire photo elec- suit factory for latest listing status. tric low-flow duct smoke detector. UL Listed:268A D4120W: InnovairFlex duct detector, includes watertight 4- ULC Listed wire photo electric low-flow duct smoke detector. CSFM: 3242-1653:0206 (D2), 3242-1653:0207 (D4120, D4P120: InnovairFlex duct detector, includes 4-wire photo- D4P120,D4S) electric power board component only,24VAC/DC, 120VAC. FM approved 2151: Replacement 2 wire conventional photo electrical sen- sor head. 2D51: Replacement 4-wire conventional photo electrical sen- sor head. D4S:4-wire photo electric sensor component only. DCOIL: 2 wire remote test coil required with RTS151/ RTS151KEY. DST1: Metal sampling tube duct width up to 1 ft(0.3m). DST1.5: Metal sampling tube duct widths up to 1 ft to 2 ft(0.3 to 0.6 m). DST3:Metal sampling tube duct widths up to 2 ft to 4 ft(0.6 to 1.2 m). DST5:Metal sampling tube duct widths up to 4 it to 8 ft(1.2 to 2.4 m). DST10: Metal sampling tube duct widths up to 8 ft to 12 ft(2.4 to 3.7 m). DH4000E-1:Weatherproof enclosure. ETX: Metal exhaust tube duct,width 1 ft(0.3 m). M02-04-00:Test magnet. P48-21-00: End cap for metal sampling tubes. RA100Z: Remote annunciator alarm LED. RTS151: Remote test station. RTS151 KEY: Remote test station with key lock. RTS2: Multi-signaling accessory(4-wire). AOS:Add-on strobe,optional accessory for RTS2. RTS2-AOS: Multi-signaling accessory (4-wire); includes AOS add-on strobe. Architectural / Engineering Specifications Notifier and FlashScan® are a registered trademark of Honeywell International Inc. The air duct smoke detector shall be a Notifier InnovairFlex D2 ®2011 by Honeywell International Inc.All rights reserved.Unauthorized use Photoelectric duct smoke detector. The detector housing shall of this document is strictly prohibited. be UL listed per UL 268A specifically for use in air handling sys- This document is not intended to be used for installation purposes. ISO 9001 We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. 9MIfftM 8 MAIMk1L11R1ti6 All specifications are subject to change without notice. SYALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-60424:61•10/5/2011 • • . DN-6994:B•Al-370 N100-1S0(A) NOTIFIER® Fault Isolator Module for FireWarden Series Panels by Honeywell Addressable General The NOTIFIER N100-ISO(A) Fault Isolator Module is used with FireWarden Series panels to protect the system against wire-to-wire short circuits on the SLC loop. The N100-ISO(A) should be placed between each device on the SLC loop to iso- late a short-circuit problem between the modules. It is required for true Style 7 operation so that other devices can continue to operate normally in the event of a short-circuit on the SLC. Features • Powered by SLC loop directly, no external power required. • Mounts in standard junction boxes (4.0'/10.16 cm square, 2.125'/5.398 cm deep). 4' • Integral LED blinks to indicate normal condition. Illuminates steady when short circuit condition is detected. • High noise(EMF/RFI)immunity. Applications The Fault Isolator Modules should be spaced between groups of sensors in a loop to protect the rest of the loop. Use to iso- late short circuit problems within a section of a loop so that other sections can continue to operate normally. The N100- N100-ISO(A) ISO(A) supports a maximum of 25 devices in-between isola- tors,except when using relay bases. NOTE:LOADS PER RELAY BASE AND ISOLATORS/ISOLATOR • Dimensions: 4.5"H x 4.5'W x 0.25" D (11.43 cm H x BASES: The maximum number of addressable devices between 11.43 cm W x 0.635 cm D). isolators(or B224BIA isolator bases)is 25 devices. 25 DEVICES Construction isolator solator The face plate is made of off-white plastic. Module includes module l module yellow LED indicator that pulses when normal and illuminates or base ~`^—� or base steady when a short is detected. 22430e•i°e•wmt detector module Operation Automatically opens circuit when the line voltage drops below B224RB relay bases draw more current than other intelligent four volts. Fault Isolator Modules should be spaced between devices. When calculating the 25-device maximum, B224RB rep- groups of addressable devices (maximum 25, see notes on resents 2.5 DEVICES;see example on page 2. page 1) in a loop to protect the rest of the loop. If a short NOTE: ON MAXIMUM NUMBER OF DEVICES: See the SLC occurs between any two isolators,then both isolators immedi- Manual(52304)for information on loss of addresses due to current ately switch to an open circuit state and isolate the groups of limitations. Each module or base added reduces the capacity of sensors between them. The remaining units on the loop con- address positions in an SLC.All SLC field devices must have been tinue to fully operate. purchased after February 1995 to meet the aforementioned requirements. If the SLC field devices were purchased prior to In Style 4 loops,the N100-ISO(A)is generally used at each T- February 1995,each isolator used reduces the capacity of an SLC tap branch,to limit the effect of short circuits on a branch to the by two address positions. Requirements differ as applied to relay devices on that branch. The LED indicator is on continuously bases;see note above. during a short circuit condition. The N100-ISO(A) Fault Isolator Module automatically restores Specifications the shorted portion of the communications loop to normal. • Operating voltage: 15—32 VDC(peak). • Maximum current upon activation due to short circuit: Installation refer to the manual for the main FACP. • Mount on a standard junction box (4.0'/10.16 cm square) • Standby current: 450 pA maximum; N100-ISO(A) is not which is at least 2.125'/5.398 cm deep. isolating—relay closed. • Terminal screws are provided for"in and out"wiring. • Temperature range:32°F to 120°F(0°C to 49°C). • Installation instructions are provided with each module. • Relative humidity: 10%to 93%. • Surface-mount box is available as an option. • Weight:5 oz. (150 grams). DN-6994:B•01/05/2012—Page 1 of 2 • • Engineering Specifications Agency Approvals and Listings Fault Isolator Modules shall be provided to automatically iso- These listings and approvals apply to the modules specified in late wire-to-wire short circuits on an SLC loop.The Fault Isola- this document.In some cases,certain modules or applications tor Module shall limit the number of modules or detectors that may not be listed by certain approval agencies, or listing may may be rendered inoperative by a short circuit fault on the SLC be in progress. Consult factory for listing details. Loop. If a wire-to-wire short occurs, the Fault Isolator Module • UL Listed: S635. shall automatically open-circuit (disconnect) the SLC loop. When the short circuit condition is corrected,the Fault Isolator • CSFM:7300-0028:0238. Module shall automatically reconnect the isolated section of • MEA:427-91-E Vol.9. the SLC loop. The Fault Isolator Module shall not require any • FM Approved. address-setting,and its operations shall be totally automatic.It shall not be necessary to replace or reset an Fault Isolator Product Line Information Module after its normal operation. The Fault Isolator Module shall mount in a standard 4'(10.16 cm)deep electrical box, in NOTE: A"sullix indicates ULC Listed model. a surface-mounted backbox, or in the Fire Alarm Control N100-ISO: Isolator module. Panel. It shall provide a single LED which shall flash to indi- cate that the Isolator Is operational and shall illuminate steadily N100-ISOA:Same as N100-I50 with ULC Listing. to indicate that a short circuit condition has been detected and SMB500:Optional surface-mount backbox. isolated. Examples of Device Counts (see notes under Applications) Starts • Next Count isolator isolator 2 module module or base detector with detectorwith or base standard base relay base module Counts as... 1 + 3.5 + 1 = 5.5 Q (2.5+1) (less than 25 total) Notifier®is a registered trademark of Honeywell International Inc. Notifler® and FireWarden® are registered trademarks of Honeywell International Inc. ®2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. I 0 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements. ttiNMIMI S WORM= All specifications are subject to change without notice. NMLITT SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6994:8•01/05/2012 • • Monitor Modules DN-6999:C NMM-100(A), NMM-100P(A), NOT 1 F 1 E R® NZM-100(A), and NDM-100(A) for FireWarden Series Panels by Honeywell Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact , input devices, such as conventional heat detectors and pull stations, or monitor and power a circuit of two-wire smoke detectors(NZM-100(A)). NMM-100(A)is a standard-sized module(typically mounts to a •� 4" [10.16 cm] square box) that supervises either a Style D (Class A) or Style B (Class B) circuit of dry-contact input "�•� devices. NMM-100P(A) is a miniature monitor module a mere 1.3' (3.302 cm) H x 2.75' (6.985 cm) W x 0.5" (1.270 cm) D that A„ (� (0 supervises a Style B (Class B) circuit of dry-contact input llyf/ �l devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. • f NZM-100(A) is a standard-sized module that monitors and - supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module NMM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the automatically panel.identifies maVshort)of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop. No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 -99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 -50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 IA (LED flashing), 1 com- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each EOL resistance:47K ohms. module is selected using the built-in rotary switches. It pro- vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit(IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4' (10.16 cm) wide x 125' (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125'(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B (Class B)or Style D(Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 • • • • NMM-100P(A) Mini Monitor Module Dimensions: 1.3' (3.302 cm) high x 2.75" (6.985 cm)wide x 0.65'(1.651 cm)deep. • Built-in type identification automatically identifies this device as a monitor module to the panel. Wire length:6'(15.24 cm)minimum, • Powered directly by two-wire SLC loop.No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 1415 0 1 ADDRESS 0 1 • Direct Decade entry of address:, 01 — 99 on FireWarden- "s 1 2 2 100-2,01 —50 on FireWarden-50. 1 3 •11 4 //n n3�I/V//� 4 LED LED latches flashes steady during to normal indicate operation.alarm on command from 1 9( 6 5 control panel. TENS ONES The NZM-100(A)Interface Module is intended for use in intelli- I n n n gent, addressable systems, where the individual address of each module is selected using built-in rotary switches. This module allows intelligent panels to interface and monitor two- 3 wire conventional smoke detectors. It transmits the status(nor- mal,open,or alarm)of one full zone of conventional detectors W V back to the control panel. All two-wire detectors being moni- 14 5 c0 tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke I I I I detectors. The monitored circuit may be wired as an NFPA Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from NMM-100P(A)APPLICATIONS the control panel and reports its type and the status(open/nor- mal/short)of Its Initiating Device Circuit(IDC).A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B) Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- Maximum current draw:5.1 mA(LED on . cuit. ( ) NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Each NMM-100P(A) uses one of the available module Average operating current: 300 pA, 1 communication and 1 LED flash every 5 seconds,3.9k eol. addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every Humidity range: 10%to 93%noncondensing. 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Shorted). Dimensions: 4.5' (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25' (3.175 cm) deep. Mounts to a 4' (10.16 cm) square x 2.125'(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:400 pA. EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 • • NDM•100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol.3(NDM-100) The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two- Product Line Information wire initiating device circuits(IDCs)at two separate,consecutive addresses. It is capable of monitoring normally open contact fire NOTE:'A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel- NMM-iD0(A): Monitor module. controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B) !DC cir- NMM-100P(A): Monitor module,miniature. cults ONLY Style D(Class A) IDC circuits are NOT supported in NZM-100(A): Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual, two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current: 240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range: 32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125" (5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, 2, 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. QCAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4" (10.16 cm)square, 2.125" (5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 • • Notifier®and FireWarden®are registered trademarks and FireWatch,"is a trademark of Honeywell International Inc. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. i, ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T I F I E We cannot cover all specific applications or anticipate all requirements. INI 8 MMIIFACTTAIl16 All specifications are subject to change without notice. NULLITY SYSTEMS Made in the U.S.A. For more information,contact Notilier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 • • dn-60383:A2 NC-100R(A) NOT 1 F 1 ER Relay Module for FireWarden Series Panels by Honeywell Addressable General The NC-100R(A) Addressable Relay Module provides NOTI- FIER's FireWarden Series intelligent control panels with two isolated sets of Form-C dry-contact outputs for activating a – variety of auxiliary devices, such as fans, dampers, door hold- ers, control equipment, etc. Addressability allows the dry con- • tact to be activated, either manually or through panel --• programming,on a select basis. _ : Features • Built-in type identification automatically identifies these °" -- devices to the control panel. • Internal circuitry and relay powered directly by two-wire SLC loop. • Integral LED "blinks" green each time a communication is received from the control panel and turns on in steady when • activated. • • • High noise immunity(EMF/RFI). • Wide viewing angle of LED. • SEMS screws with clamping plates for wiring ease. NC-100R(A) • Direct Decade entry of address: 01 -99 with the FireWar- den-100-2(C)and 01 -50 with the FireWarden-50(C). Applications The NC-100R(A)may be programmed to operate dry contacts Specifications for door holders, Air Handling Unit shutdown,etc.,and to reset Normal operating voltage: 15 to 32 VDC. four-wire smoke detector power. Maximum SLC current draw: 6.5 mA(LED). Construction Average operating current: 230 pA direct poll (CLIP mode), • The face plate is made of off-white heat-resistant plastic. 255 pA group poll with LED flashing. • Controls include two rotary switches for direct-dial entry of EOL resistance: not used. address setting. Temperature range: 32°F to 120°F(0°C to 49°C). • The NC-100R(A) provides two Form-C dry contacts that Humidity range: 10%to 93%non-condensing. switch together. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Operation 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 mm)deep box. Each NC-100R(A)uses one of the addresses on a SLC loop.It responds to regular polls from the control panel and reports its Relay Contact Ratings type and status. The LED blinks with each poll received. On command,it activates its internal relay. Maximum Current Load Description Application Voltage Rating Rotary switches set a unique address for each module. The 9 g address may be set before or after mounting. The built-in Resistive Non-Coded 30 VDC 3.0 A TYPE CODE (not setlable)will identify the module to the con- trol panel. Resistive Coded 30 VDC 2.0 A Resistive Non-Coded 110 VDC 0.9 A Resistive Non-Coded 125 VAC 0.9 A Inductive(LJR=5ms) Coded 30 VDC 0.5 A Inductive(L/R=2ms) Coded 30 VDC 1.0 A Inductive(PF=0.35) Non-Coded 125 VAC 0.5 A dn-60363;A2•06/17/10—Page 1 of 2 • Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL/ULC Listed:S635. • CSFM approved:file 7300-0028:230. • FM approved. • MEA approved:file 72-01-E,Vol.2. Product Line Information NC-100R: Intelligent addressable relay module. NC-100RA: Intelligent addressable relay module, ULC listed model. SMB500:Optional surface-mount backbox. NOTE: For installation instructions, see document 156-2593-001 and refer to the SLC Wiring Manual,document 52304. NOTIFIER®is a registered trademark of Honeywell International Inc. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 'YO 9��1 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T I F I C O We cannot cover all specific applications or anticipate all requirements, s All specifications are subject to change without notice. 11l1LITY MUMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—dn-60383:A2•06/17/10 5,C,Q 1L4- 357) oON c°G� JiERSON COUNTY • DEPARTMENT OF COMMUNITY DEVELOPMENT 9sx�" o 621 Sheridan Street I Port Townsend,WA 98368 I Web:www.co.iefferson.wa.us/communitydevelooment Tel:360.379.4450 I Fax:360.379.4451 I Email:dcd(n7co.jefferson.wa.us Building Permits &Inspections I Development Consistency Review I Long Range Planning I Watershed Stewardship Resource Center Master Permit Application MLA: Project Description(include separate sheets as necessary): Install, program and commission a new Notifier NFW-100 fire alarm system. Tax Parcel Number: 001332009 Property Size: 13060 sq ft (acres/square feet) Site Address and/or Directions to Property:63 Four Corners Rd Property Owner(s)of Record: Jefferson Transit Authority Ii EC [ V1 Telephone:360/3854777 Fax: 360/385-2321 emal: IP� effersontranslt.com Mailing Address: 63 Four Corners Rd,Port Townsend,WA 98368 SEP 2 9 2014 Applicant/Agent(If different from owner): Fire Chief Equipment/Mark Kushino J Telephone:425/522-1226 Fax: 425/562-6662 emelt a �mfire-chief.com l'J Mailing Address: 7661 159th PINE,Redmond,WA 98052 JEFFERSON COUNIY DEM or Covk1UM1Y DEVELerMENT What kind of Permit?(Check each box that applies ❑Lot or Road Segregation Building ❑Critical Areas Stewardship Plan ❑ Demolition Permit ❑Variance(Minor, Major or Reasonable Economic Use) ❑Single Family ❑Garage Attached/Detached ❑Conditional Use[C(a),C(d),or C]** ❑ Manufactured Home ❑ Modular ❑ Discretionary"D"or Unnamed Use Classification RI Commercial* ❑Special Use(Essential Public Facilities)** ❑ Change of Use ❑Boundary Line Adjustment ❑ Address ❑Road Approach ❑Short Plat** ❑Home Business ❑Cottage Industry ❑Binding Site Plan** ❑Propane ❑Long Plat** ❑Sign ❑ Planned Rural Residential Development(PRRD)/Amendments** ❑Allowed"Yes"Use Consistency Analysis ❑ Plat Vacation/Alteration** ❑Stormwater Management ❑Shoreline Master Program Exemption/Permit Revisions** ❑Site Plan Approval Advance Determination(SPAAD)* ❑Shoreline Management Substantial Development** ❑Temporary Use ❑Shoreline Management Variance ❑Wireless Telecommunication* ❑Comprehensive Plan/UDC/Land Use District Map Amendment ❑Forest Practices Act/Release of Six-Year Moratorium ❑Jefferson County Shoreline Master Program Amendment *May require a Pre—Application Conference ❑Tree Vegetation Request **Requires a Pre-Application Conference Please identify any other local, state or federal permits required for this proposal, if known: Existing permit#s: BLD14-0004, BLD14-0005, BLD14-0006, BLD14-0032 Mark Kushino DESIGNATION OF AGENT I hereby designate to act as my agent in matters relating to this application for permit(s). Jefferson Transit Authority "�n;<m 9/10/14 OWNER SIGNATURE - Date: By signing this application form,the owner/agent attests that the information provided herein,and in any attachments,is true and correct to the best of his,her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in this permit being null and void. I further agree to save,indemnify and hold harmless Jefferson County against all liabilities,judgments,court costs,reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees,representatives or agents for the sole purpose of application review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the application that he or she wants prior notice. Signature: Mark Kushino,, ,`;;; m Date: 9/22/14 The action or actions Applicant will undertake as a result of the issuance of this permit may negatively impact upon one or more threatened or endangered species and could lead to a potential lake"of an endangered species as those terms are defined in the federal law known as the "Endangered Species Act"or"ESA."Jefferson County makes no assurances to the applicant that the actions that will be undertaken because this permit has been issued will not violate the ESA. Any individual,group or agency can file a lawsuit on behalf of an endangered species regarding your action(s)even if you are in compliance with the Jefferson County development code.The Applicant acknowledges that he,she or it holds individual and non-transferable responsibility for adhering to and complying with the ESA. The Applicant has read this disclaimer and signs and dates it below. Signature: Mark Kushino Date: 9/22/14 07/24/2013 • • BUILDER STATEMENT • The signer of this statement does hereby certify that they are the Owners of the parcel referenced herein,that they are not licensed contractors and that they will be assuming the responsibility of the General Contractor for the proposed project. Jefferson Transit Signature: Authority _,01d„_m, 9/22/14 Date: GENERAL CONTRACTOR OR MANUFACTURED HOME INSTALLER: PHONE: FAX: Fire Chief Equipment (360/345-4777 (360/345-2321 MAILING ADDRESS: 63 Four Corners Rd, Port Townsend,WA 98368 EMAIL: info @jeffersontransit.com CONTRACTOR'S LICENSE WAINS NUMBER: FIRECCE938JR NUMBER 602-683-436 ARCHITECT/ENGINEER: Bob Vogt PHONE (360/45-4777 FAX:(360/315-2321 MAILING ADDRESS: 63 Four Corners Rd,Port Townsend,WA 96368 EMAIL info@jeffersontransit.com Project Type: Frame Type: Bathrooms: Shoreline: Type of Sewage Disposal: ❑ New 1 Wood Existing: Addition ❑ Steel Proposed: Bank it�S -= r ❑ Alteration/Remodel ❑ Concrete Total: Heigh : D ❑ Individual System ' I ❑ Repair ❑ Masonry 139 SEP Permit# Demolition ❑ Other: Bedrooms: yy nS Existing: Setback: r T,f:2014 Type of Heat: Proposed: ❑ nv well Twr I- y Total: L.) Cp{Public INaWft•NSTOff TY , [1rlT RF ri-11.4'11IPLITY OP;R 0^MFPIT If this is a Commercial Project you must answer the following: Number of Parking Spaces: Current: Proposed: Number of ADA Parking Spaces: Number of occupants(includes owners,tenants,employees,etc) Current Proposed IBC Occupancy: IBC Type of construction: Will you have Food Service? Yes / No If this is a Propane Tank and/or Appliance Installation permit,mark all items below that apply: Underground Tank Above ground tank Size of Propane Tank: Heat Stove Cook Stove Woodstove Fireplace.nsert rehtO i evotS telleP i knaT retaW toH I Is this appliance being installed in a Manufactured/Mobile Home? Yes / No When applying for a permit to install a propane tank you must also submit a site plan showing all of the buildings,all property lines, tank location and size,distances from the propane tank to all property lines,buildings and septic system components, including the reserve area. Square Footage Current Proposed For Office Use Only Amount Revision Main Floor Heated 12186 12186 EH Bid App Review: 2°Floor Heated Consistency Review: Other Heated Base fee: Mezzanine 874 874 Additional Section: Heated Basement Plan Check fee: 1`-i‘--)..C\S Unheated Basement State Surcharge fee: S So Other Unheated Pte: Garage/Carport S'c - �` O� SUBTOTAL Decks 911/Rd Approach fee: Other TOTAL: $ _I■._01, LIS Receipt Number: 151 5S0 Cash/Check Number: I l 8t8 ESTIMATED COST(REQUIRED) Date: 2-9^1 •Fair market value of all labor and materials foundation to finish $15458.00 Initials: 07/24/2013 • ,r"11 FIRE CHIEF r _ EQUIPMENT 7661 159' PI NE,Redmond WA 98052 Telephone No.425-641-2127/Fax No.425-562-6662 LETTER OF TRANSMITTAL — Fire alarm permit submittal To: Jefferson County Dept. of Date: 9/26/14 Job No. 14-1300 Community Development 621 Sheridan Street Attention: Permit intake Port Angeles, WA 98368 Re: Jefferson Transit Authority WE ARE SENDING YOU: ® Enclosed ® Drawings ® Data Sheets ❑ Permit Qty Date Rev. Sheets Description 1 2 Master Permit Application for fire alarm system 3 9/10/14 0 5 Drawings for Jefferson Transit Authority 3 15 Equipment cut sheets with table of contents 1 Check#11808 for$467.45 to Jefferson County These are transmitted as checked below: ® For your approval ❑ Approved as submitted ❑ Resubmit 2 copies for approval ❑ For your request ❑ Approved as noted ❑ Submit copies for distribution ❑ For your records ❑ Returned for Corrections ❑ Return corrected prints ❑ FOR BIDS DUE: ❑ Drawings returned after loan to us ❑ Return signed copy(ies). ❑ For your information ❑ Signed Original Contracts REMARKS: Hard copies sent via UPS on this date. Please contact Mark upon permit issuance. markk(afire-chief.com 425/522-1226 Signed: Robert Vogtg BobV @ fire-chie£com -- Engineered Systems [ Cell 206-930-5003; DID 425-522-1225 If enclosures are not as noted, kindly notify us at once SEP 2 g 2014 I JEFFERSON COUNTY DEPT.OF COMMA DEVELOPMENT Parcel Print Page 1 of 1 • • Parcel Number:001332009 08/15/2014 Owner Mailing Address: JEFFERSON TRANSIT 1615 W SIMS WAY PORT TOWNSEND WA 98368-3090 Site Address: 63 FOUR CORNERS RD PORT TOWNSEND 98368-3090 Section: 33 School District: Port Townsend(50) Qtr Section: NW 1/4 Fire Dist: Chimacum(1) Township: 30N Tax Status: COUNTY Range: 1W Tax Code: 0111 Planning area: 98368-3090 Sub Division: Land Use Code: 9700 98368-3090 Property Description: S33 T3ON R1W TAX 98 BND THRU BLA#101626 http://www.co.jefferson.wa.us/assessors/parcellparcelprint.asp?PARCEL N0=001332009 9/29/2014 FIRE CHIEF EQUIPMENT CO INC Page 1 of 2 . ill ilk 41,40 Washington State Department of Labor & Industries FIRE CHIEF EQUIPMENT CO INC Owner or tradesperson 7661 159th Place NE RUCH, ROBIN LYNN REDMOND. WA 98052 425-641-2127 Principals KING County RUCH, ROBIN LYNN, PRESIDENT HARRIS, ERIN LOUISE, SECRETARY Doing business as FIRE CHIEF EQUIPMENT CO INC WA UBI No Business type 602 683 436 Corporation License Verify the contractor's active registration/license/certification (depending on trade) and any past violations. Construction Contractor Active. Meets current requirements. License specialties FIRE PROTECT SYSTEM License no. FIRECCE938JR Effective—expiration 04/19/2007—04/19/2015 Bond HARTFORD FIRE INS CO $6,000.00 Bond account no 34BSBEN1390 Received by x= Effective date 04/19/2007 04/05/2007 Expiration date Until Canceled Insurance Burlington Ins Co $1,000,000.00 Policy no. HGL0037688 Received by L&I Effective date 03/26/2014 04/01/2014 Expiration date 04/01/2015 https://secure.lni.wa.gov/verify/Detail.aspx?UBI=602683436&LIC=FIRECCE938JR&SAW= 9/29/2014 JEFFERSONNUNTY DEPARTMENT OF COMMUNITY EVELOPMENT Automatic Fire Alarm System Fire Protection System Inspection Checklist: General • Building Permit No.: /340•/4'' 41.3"4-0 • Facility Owner/Mgr.: 712.41)/Ji • Facility Address: l03 fovLcoX.v' i • Facility Name: . 7724ttf, • Facility Contact No.: S stem_: �,/ ®'Manual lF7 Automatic ❑Voice ❑ Monitored ❑Graphic ❑ Stand Alone Elements: ❑ Heat ❑ Ijate of Rise moke 0 Horn 1‘m/Strobe ❑ Strobe ❑Coiling Door anual Pulls i'■uct ❑ Egress Control ❑ Damper ❑ Other: Contractor's State License[&NICET]: Inspector Int.&Dt.: Plan Review Inspector Int.&Dt.: ❑ Plans Received[Date: 09/ 9/41] ❑ Mfr.Specifications of individual elements I fe /A BF...V`f'C/A/ ❑ Floor Plan(s)complete ❑ Battery Calculations,wring types and sizes. /1 4/ Imo/e'W ❑ Power connection,Emergency Power Source Site Inspection Inspector Int.& System installation/location check-off d' Panel Location emote Annunciation Access Keys ▪ Labeling Er Operating Instructions.Kyiwsrtr' $'•Tools System Test(s) spector Int.& Dt.4°/f/1/IS-- Heat ❑ Rate of Rise ,Smoke ❑Horn 12frorn/Strobe 0✓ct Egress Control anual Pull-station ❑,gtrobe /Monitoring Agency Test 0'Emergency Power Sourc& Q yc Fire Alarm System Inter-tie with Sprinkler System Test(Tamper): - Secs.,.0-1 Glc./ V "' -�} Contractor's Material&Test Certificate: Inspector Int.& Dt.: As-Built Plans/Instructions in Plan Box RkePt fozor e+e Inspector Int.&Dt.: Monitoring Agency • Name: /9L4'7/L(, Gnu TEJZ • Address: 7b41 ' /s j r 44.e N.E , ,P.eD4,€OA1p • Contact Number: z 5' - /. >/ 2./ Z 7' • Account Number: Panel Reset Code • Code Number: /' i• 1.1/ / Approval/Denial • Inspector: • Date: �f rr • Filed wfBldg.Official: /S • • Mary Blain From: Mary Blain Sent: Tuesday, June 16, 2015 2:12 PM To: 'Samantha Trone' Subject: contractor info for BLD14-00350 Sam, I have the file for BLD-00350 on my desk and Tom says he's missing the Contractor's Materials and Test Certification from the Fire Alarm Company to final it.There are multiple permits so I'm not entirely certain this hasn't already been addressed, so I'm asking anyways,since the file was sitting in the "revision" area. Thanks! Mary Blain Plans Examiner I Dept of Community Development 621 Sheridan St Port Townsend, WA 98368 ph: 360-379-4461 fax: 360-379-4451 mblain@co.jefferson.wa.us All e-mail sent to this address has been received by the Jefferson County e-mail system and is therefore subject to the Public Records Act,a state law found at RCW 42.56.Under the Public Records law the County must release this e-mail and its contents to any person who asks to obtain a copy(or for inspection)of this e-mail unless it is also exempt from production to the requester according to state law,including RCW 42.56 and other state laws. it 1 III 0 _ Jefferson County Building Division Permit Number: BLD14-00350 Applicant: JEFFERSON TRANSIT BUILDING PERMIT INSPECTION APPROVALS Applicable Code: 2012 International Building Codes To schedule inspections, call (360)379-4455 no later than 3:00PM the day before the inspection is needed. Requests received after 3:00 PM will not be scheduled for the next day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Fire Alarm Init. Device / f )42i� 4.1.),,,. A final inspection will not be scheduled until the following are completed and signed off by the applicable Department: • Building Permit Conditions are met • Septic Permit Final/Complete for any building containing plumbing • Land Use Conditions met and signed off • Public Works Permit Final(where applicable) FINAL INSPECTION -7/74/( 11 ( r rr -1Jr.", 'NO,v....0e — FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR • BUILDING PERMIT • Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT #: BLD14-00350 Received Date: 9/29/2014 SITE ADDRESS: 63 FOUR CORNERS RD Issue Date 10/14/2014 PORT TOWNSEND, 98368 Expiration Date 10/14/2015 OWNER: JEFFERSON TRANSIT PHONE: 1615WSIMSWAY PORT TOWNSEND WA 98368-3090 SUBDIVISION: Block: Lot: PARCEL NUMBER: 001332009 Section: 33 Township: 30 N Range: 1111 CONTRACTOR: FIRE CHIEF EQUIPMENT PHONE: 425-522-1226 MARK KUSHINO 7661 159TH PL NE REDMOND WA 98052 Contractor's License FIRECCE938JR Expires 4/19/2015 PROJECT DESCRIPTION: NEW NOTIFIER NFW-100 FIRE ALARM SYSTEM TYPE OF WORK COM SQUARE FOOTAGE: COMMERCIAL: TYPE OF IMP MEC MAIN: INDUSTRIAL: VALUATION 15,458.00 ADD'L: HEAT TYPE: CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OCCUPANCY: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: Type Amount Paid By: Date: Receipt: BATHROOMS: Permit $223.00 JLA 09/29/14 151550 Exist: Plan Check $144.95 JLA 09/29/14 151550 Prop: State Building Code $4.50 JLA 09/29/14 151550 Total: Total: $372.45 NUMBER OF EMPLOYEES: Directions to Site: HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. Request must be received by 3pm the day before the inspection is needed. Office Hours 9:00 am -4:30 pm MONDAY - THURSDAY HOT LINE AVAILABLE 24 HOURS A DAY