Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BLD2015-00176 - MECHANICAL
S • MECHANICAL AND DEMOLITION PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend, WA 98368 (360)379-4450 FAX (360)379-4451 PERMIT#: BLD15-00176 Received Date 5/28/2015 SITE ADDRESS: 33 W ROSE ST Issue Date 5/28/2015 QUILCENE, 98376 APPLICANT: UNITED TELEPHONE OF NW PHONE: C/O CENTURYLINK-PROPERTY TAX D 700 W MINERAL AVE LITTLETON CO 80120 1-5 SUBDIVISION: 9998 -WORTHINGTON'S Block: 1 Lot: PARCEL NUMBER: 999800101 Section: 24 Township: 27N Range: 2W CONTRACTOR: JOHANSEN MECHANICAL INC PHONE: (425)481-2266 PO BOX 1768 WOODINVILLE WA 98072 Contractor's License JOHANMI173PK Expires 2/1/2016 OWNER, UNITED TELEPHONE OF NW PHONE: if different: C/O CENTURYLINK-PROPERTY TAX D 700 W MINERAL AVE LITTLETON CO 80120 PROJECT DESCRIPTION: NEW MECHANICAL PERMIT Directions REPLACE EXISTING SPLIT AC UNIT WITH NEW MODIFY To Site: DUCTWORK, INSTALL 2 LOUVERS, 1 WALL MOUNTED EXHAUST FAN ANTI s LFS THIS PERMIT IS VALID FOR ONE YEAR AND IS NOT RENEWABLE. THE FINAL INSPECTION MUST BE SCHEDULED AND PASSED WITHIN THAT YEAR. THE EXPIRATION DATE IS 5/28/2016. REQUIRED INSPECTIONS: Installation per Manufacturer Specifications/CO2: Tank/Line/Appliance: Final Approval: 6((C/(1 BUILDING INSPECTION HOT-LINE 379-4455. REQUESTS MUST BE RECEIVED BY 3 PM THE DAY BEFORE THE INSPECTION IS NEEDED. Office Hours 9:00 a.m. -4:30 p.m. Monday-Thursday HOT LINE AVAILABLE 24 HOURS A DAY \\tidemark\data\forms\F_BLD_Permit_Propane.rpt 5/28/2015 IPUILDING PERMIT APPLICASN BLD15-00176 Review Type: Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 PERMIT#: BLD15-00176 Received Date: 5/28/2015 SITE ADDRESS: 33 W ROSE ST QUILCENE, 98376 OWNER: UNITED TELEPHONE OF NW PHONE: C/O CENTURYLINK-PROPERTY TAX D 700 W MINERAL AVE LITTLETON CO 80120 9998-WORTHINGTON'S SUBDIVISION: Block: 1 Lot: 1-5 PARCEL NUMBER: 999800101 Section: 24 Township: 27 N Range: 2V1 CONTRACTOR: JOHANSEN MECHANICAL INC PHONE: (425)481-2266 PO BOX 1768 WOODINVILLE WA 98072 Contractor's License JOHANMI173PK Expires 2/1/2016 REPRESENTATIVE: PHONE: PROJECT DESCRIPTIOI NEW MECHANICAL PERMIT REPLACE EXISTING SPLIT AC UNIT WITH NEW MODIFY DUCTWORK, INSTALL 2 LOUVERS, 1 WALL MOUNTED EXHAUST FAN AND 5 GRILLES. TYPE OF WORK NON SQUARE FOOTAGE: TYPE OF IMP MEC MAIN: VALUATION CODE EDITION: 2012 ADD'L: HEAT TYPE: OCCUPANCY: HEAT BASE: HEAT TYPE: OCCUPANCY: UNHEATED: #OF STORIES: OTHER: CONST TYPE: GARAGE: SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: BEDROOMS: BATHROOMS: Exist: Exist: Prop: Prop: Total: Total: Routing Date: Type Amount Paid By: Date: Receipt: Approved/Date Permit $156.00 SRE 05/27/15 156115 jpp®ovED Total: $156.00 APPROVED MAY 2 8 2015 Jefferson County DCD \1fiAem oh\rhfn\fnre\F RI fl Ann RIel rnf 6/95119(11 • • ,ccL$ON DEPARTMENT OF COMMUNITY DEVELOPMENT tt<s, O6. 621 Sheridan Street,Port Townsend,WA 98368 W Tel:360.379.4450 I Fax:360.379.4451 — Web:www.co.jefferson.wa.us/communitvdevclopment E-mail:dcdtco.jefferson.wa.us 46'111 N G t� MECHANICAL PERMIT APPLICATION Steps in the Permit Process: -Review required submittal items to ensure all information is completed prior to submitting application. -Mechanical Permits can be mailed into our office-and do not require an appointment. -Fees are due at time of submittal, Mechanical permits are generally issued within 5 business days. For Department Use Only Receipt i#: Date: Related Application Us: Payment#: Is this application for use in a Mobile/Manufactured Home? * If Yes: A permit from Washington State Department of Labor and Industries, not Jefferson County, is required for appliances installed within a mobile/manufactured home. L&I-360-417-2702 * If No: Complete this form and make an appointment to submit to Jefferson County Permit Tech 360-379-4450 Required Submittal Items—for propane tank only LGeneral Site plan —showing propane tank, lines, and distance from tank to all existing structures. Required Submittal Items—for Solar Panel installation only Complete first page and signature block only of Mechanical Permit Application. A complete solar panel supplemental application. Site Information Assessor Tax Parcel Number:999800101 Site Address and/or Directions to Property:33 West Rose St, Quilcene, WA Access (name of street(s)from which access will be gained:West Rose St Description of Work: N _ - - 'II • a N• ' a N. Nisi' I N - • - , __ NN• N -N - I - fan, and 5 grilles. Property Owner Name: CenturyLink Address: 1249 NE 145th St, Seattle, WA Phone#: E-mail Address: Applicant/Contractor: Authorized Agent/Representative Name: Johansen Mechanical, Inc. Phone#: 425-481-2266 E-mail Address: ivyl @johansenmech.com License#: JOHANMI173PK Expiration Date: 2/2/17 Mechanical Application 1 • • Heat Source Electric Heating Oil I-I Propane* I Wood I� Indicate Quantity and Fixture Types Below *Propane is prohibited in Quantity Fixture Type Description hazardous locations such as 1 Fan Bath Fan and/or Exhaust Fan basements or pits or Clothes Dryer Clothes Dryer with Exhaust Vent anywhere "heavier-than-air" Cook Stove Cook Stove, Range Hood Exhaust gas can unsafely collect. Fireplace-Gas Fireplace-Gas or Gas Log Insert *Propane tanks over 125 Fireplace-Wood Fireplace-wood,Wood Stove,or gallons require a minimum Pellet Stove setback of 10 ft.from Electric Furnace Electric Furnace or HP+/-Ducting property line and buildings, Propane(LP)Gas Furnace Propane Furnace+/-Ducting and a site plan must be submitted with the Water Heater-Gas Gas WH Vent and Combustion Air application showing the Gas Pipe System Gas Pipe System LPG/Oil setbacks. If propane tank is Propane Tank LP Fuel Tank(#gallons: 1 over 500 gallons, a site plan is Heat Pump required to accompany this Generator application,and a separate 1 Air Conditioner Fire Code approval is also required. Installation manual must be on site at time of inspection or a re-inspection fee will be charged. By signing this application form, the owner/agent attests that the information provided herein, and in any attachments, is true and correct to the best of his, her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in making any issued permit null and void. I further agree to that all activities I intend to undertake or complete associated with this permit will be performed in compliance with all applicable federal, state and county laws and regulations and I agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections. Applicant may request notice of the County's intent to enter upon the property for visits related his applical n and subsequent permit issuance. Property Ivy LeVangie Date: 5/4/15 Signature. Print Name: OFFICE USE ONLY Building Permit Fees Mechanical Permit fee (tank swap,woodstove,furnace,etc) $156.00 Propane— Lines, tank, and appliance (add'I $78.00) Project Scanning Fee $19.50 Total Fees* )r1$ . S v *Additional fees may apply. COOWD ' VC)CP-4:(11-4 l\qcnical Application 2 • S Cindy Holm From: Creegan, Lisa <Lisa.Creegan @CenturyLink.com> Sent: Wednesday, May 20, 2015 11:48 AM To: Cindy Holm Cc: Creegan, Lisa Subject: Quilcene HVAC Project Cindy, This email authorizes Johansen Mechanical to obtain permits on the behalf of Centurylink as part of our project to replace an existing HVAC unit at the Quilcene CO located at 33 W. Rose St. Quilcene, WA 98376 Lt a.Cree ja.vv SR Project Manager Design & Construction 1249 N.E. 145th St. Room 101 Seattle, WA 98155-7133 206-345-4416 lisa.creegan @centurylink.com This communication is the property of CenturyLink and may contain confidential or privileged information. Unauthorized use of this communication is strictly prohibited and may be unlawful. If you have received this communication in error, please immediately notify the sender by reply e-mail and destroy all copies of the communication and any attachments. i ... - ...., . ■ ... , 1 ,, , . ..., ,..'!"4.77 -i • ., . - . • _ . , 4 1 ' ' .., 1111111.11111111L 4r4 I --,-.. - • - . .-- - , . _.. I '-*-- . .,, .f.% it • _ .... ,.. -- ,• ri....„ „,,i..... ,.. lit41.*-„--:, ,„,t31„. 44*''''',"" ''',1 itiii 1:*,,,,,,1111111.111'.% _sautp.‘'41/.'7!47'.1zi ,:.4'!* '%,....: -: ' '. • 41.' ';''‘• 1.. ° PI ,.. - . 4,.. ---; 1"''4444-to''. .. „ -IT- , ,,,i4-,. tt..= . ' — '"•7 ‘ :•`,".':i4 t ,. , . .- „. -7; - .!.,fig's . .&.- '.. :A: ,-:, ...i.:0, 0, ,„, ,• ..;#4 ' Irmo ,..=.744 . ''''' - , .3'. [44 I tiiiiii„. A,...!...'__ 4..„,•*.1 ..... __ **. - . r-.- ..- .., „ . ‘4.* .... . i , , t f . 6.„, „, . - 7...=. — . C.-.1,:, .. ,„„,. 414, . -' - , , _ , -, .r.- .,..., . . . .. ..,, • . . . 1 - .." _ -.... -4; „... ('-' g: %.... '. .., •., -.., Q„) ,ta `,...1 7 ..... --, .... e . .- - ... ::-., mom -1•11'71-- .,..,:z.: ....%t, '.' . _ a , , 1.1 4., = .. . ... ..... —— 2!.., f.- ' : • , s ,. ......„ 4 • r , . ., '' •!wl' '''" r --,..„,.. - I '.. . Li' 1:* ,- .. ___.-& g o`d -11,, 1S4.51,1 ---g -11"r , -t-- smorm co ' en a 0 C.) ''lle 77 4 g 4 I a 'I ... i.4 In. JOHANSEN MECHANICAL, INC. 066531 Remittance Advice •• • Pant of l Check: 66531 Paid by: Johansen Mechanical, Inc. Our Account#: Date: 05/19/15 Paid to: JEFFERSON COUNTY Vendor Code: JEFCOU Amount: 175.50 Inv.Date Invoice No. Job Number Inv.Amount Discount Amount Paid Retention Remarks 05/19/15 PERMIT D30150 D30150 175.50 0.00 175.50 0.00 PERMIT D30150 Check Totals 175.50 0.00 175.50 0.00 DETACH AND RETAIN THIS STATEMENT CA4066658 FMDC-CON 98001 10/98 JOHANSEN MECHANICAL INC Page 1 of 2 Home Inicio en Espanol Contact Search L&I .. A-Z Index Help My Secure L&I Safety Claims&Insurance Workplace Rights Trades&Licensing ciki Washington State Department of Labor & Industries JOHANSEN MECHANICAL INC I Owner or tradesperson 20109 144TH AVE NE WOODINVILLE,WA 98072 Principals 425-481-2266 JOHANSEN,ALLEN D KING County JOHANSEN,ANITA J Doing business as JOHANSEN MECHANICAL INC WA UBI No. Business type 600 495 164 Corporation Governing persons ALLEN JOHANSEN KEITH JOHANSEN; License Verify the contractor's active registration/license/certification(depending on trade)and any past violations. Construction Contractor Out of Business. License holder has notified L&I it is no longer In business.Owner may have other active licenses under different business names. License specialties GENERAL License no. JOHANMI173PK Effective—expiration 10/12/1983—02/02/2017 Bond DEVELOPERS SURETY&INDEM CO $12,000.00 Bond account no. 275167C Received by L&I Effective date 08/02/2010 07/31/2010 Expiration date Until Canceled Bond history Insurance ..........._......... American Fire&Casualty Co $1.000.000.00 Policy no. BKA55005445 Received by L&I Effective date 01/23/2015 02/01/2014 Expiration date 02/01/2016 Insurance history https://secure.lni.wa.gov/verify/Detail.aspx?UBI=600495164&LIC=JOHANMI 173PK&SAW= 5/28/2015 JOHANSEN MECHANICAL INC _ Page 2 of 2 Savings No savings accounts during the previous 6 r period. Lawsuits against the bond or savings No lawsuits against the bond or savings accounts during the previous 6 year period. LW Tax debts No L&I tax debts are recorded for this contractor license during the previous 6 year period,but some debts may be recorded by other agencies. License Violations No license violations during the previous 6 year period. Workers' comp Do you know if the business has employees?If so,verify the business is up-to-date on workers'comp premiums. L&I Account ID Account is current. 482,787-00 Doing business as JOHANSEN MECHANICAL INC Estimated workers reported Quarter 1 of Year 2015"76 to 100 Workers" L&l account representative 721 HAN CHUNG(360)902-4713-Email:CHUK235 @Ini.wa.gov Workplace safety and health Check for any past safety and health violations found on jobsites this business was responsible for. Citation issue date 04110/2012 Violations Inspection no. 315897447 Location Boeing Developmental Center Tukwila,WA 98108 Citation issue date 03/10/2010 Violations Inspection no. 313924359 Location 20109 144th Ave Ne Woodinville,WA 98201 ©Washington State Dept.of Labor&Industries.Use of this site is subject to the laws of the state of Washington. 7 _ _ — A 5/28/2015 v veri /Dctail.as x.UBI 600495164&LIC JOHANM1173PK&S W https://secure.lm.wa.go / fy p /11 SLat Johansen Mechanical inc. 20109 144th Ave NE•Woodinville,WA 98072 (425)481-2266 Bus • (425)486-6933 Fax II LETTER OF TRANSMITTAL TO: Jefferson County From: Ivy LeVangie 621 Sheridan St Date 05/08/15 Port Townsend, WA 98368 Project Chimacum &Quilcene Job# P11804/D30150 ATTN: Dept of Community Development Reference: Permit Applications WE ARE SENDING YOU: AS REQUESTED UNDER SEPARATE COVER VIA THE FOLLOWING ITEMS: SHOP DRAWINGS PRINTS PLANS CHANGE ORDER COPY OF LETTER O&M'S SPECS SUBMITTALS COPIES DESCRIPTION 1 Copy permit application packet and payment- CenturyLink Chimacum 1 Copy permit application packet and payment - CenturyLink Quilcene THESE ARE TRANSMITTED as checked below: X For Approval Approved as Submitted Resubmittal For Your Use Approved as Noted Submittal Resubmit As Requested Returned for correction Please Return(1 copy) For Review and Comment Per you Request Immediate Action For Bid(s)Due For Signature FYI COMMENTS: COPY TO: Job File �/� 71'7 ! e"-i ZPi SIGNED O RECEIVED BY: DATE: 5/8/2015 Transmittal sheetl ' i . Submittal 3-1/2 Ton Convertible Air Handler TEM4A0C42S41SA tq' o • a . • 0 • 0 • • .r TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. July 2014 TEM4A0C42-SUB-IA-EN OVIngersolRand TWINE" NW Outline Drawing 21.13 1.44 MI5—.T.—J.1/ MINIMUM UNIT CLEARANCE TABLE 1.110 TO ..■ COMBUSTIBLE SERVICE ATERIAL CLEARANCE M (MATERIAL (RECOMMENDED] SIDES 0' 2• I FRONT D' 21' I01.14 BACK D' 0' B C INLET DUCT 0' I' GIJTLET DUCT I'I NIA EL CTR CN[1115T J I OJ LLED:T'DUCT EREII 5'11 616113 fI[AJE13 AK IYf 1ALA[D:0'6TF1 iN[ 2.59 1.01-4 2.13 I'- 02.00 2.13 au .{ 0.11 - } o 3.13 17- \ 0 En I 02.02 01.38 1• 1 A 01.32 nr r l.n (h —f+ uJ 1 H :. , ' � s.ITe • } i 112 i 1.33 .4J--•••• 14.16 x-1.12 3.11 - fL20 {� 2 11CS ` .411 -I I .M jj 2.15 ■ B FE m p F F D I 1 }2 ! a .47 J PRODUCT DIMENSIONS Air Handler Model A B C ID E F H Flow Gas Line Control Braze TEM4A0C42541SA 51.27 23.50 21.50 21.75 7.01 9.66 24.59 TXV 7/8 All dimensions are in inches 2 TEM4A0C42-SUB-1 A-EN ��— TRANE° Product Specifications MODEL TEM4AOC42S41SA Coupling or Conn.Size— 3/8 in.Liq. RATED VOLTS/PH/HZ 208-230/1/60 DIMENSIONS H x W x D RATINGS(a) See O.D.Specifications - Crated(In.) 52-1/2 x 26 x 24 INDOOR COIL—Type Plate Fin Uncrated 51-3/8 x 23-1/2 x 21-1/8 Rows—F.P.I. 3-14 WEIGHT Face Area(sq.ft.) 5.50 Shipping(Lbs.)/Net(Lbs.) 145/138 Tube Size(in.) 3/8 - (a) These Air Handlers are A.H.R.I certified with various Split System Air Refrigerant Control TXV Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to the Split System Outdoor Unit Product Data Guides for performance Drain Conn.Size(In.)(b) 3/4 NPT data. (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) DUCT CONNECTIONS See Outline Drawing (c) ECM Motor (a) Remote filter required. INDOOR FAN—Type Centrifugal Diameter-Width(In.) 10X10 Minimum Airflow CFM No.Used 1 TEM4AOC42S41SA Drive-No.Speeds Direct-3 CO Heater Minimum Heat Speed Tap CFM vs.in.w.g. See Fan Performance Table With Heat Without Heat Pump Pump No.Motors—H.P. 1-1/2 BAYHTR1504BRK, Motor Speed R.P.M. 1050 BAYHTR1504PDC, Volts/Ph/Hz 208-230/1/60 BAYHTR1504WG, Low Low BAYHTR1505BRK, BAYHTR1505PDC, F.L.Amps 4.1 BAYHTR1505LUG FILTER BAYHTR1508BRK, Filter Furnished?(a) No BAYHTR1508PDC, BAYHTR1508LUG, REFRIGERANT R-410A BAYHTR1510BRK, Low Low BAYHTR1510PDC, Ref.Line Connections Brazed BAYHTR1510LUG, BAYHTR3510LUG Coupling or Conn.Size— 7/8 BAYHTR15158RK, in.Gas BAYHTR3515LUG, Low Low BAYHTR1520BRK TEM 4AOC42-SUB-1 A-E N 3 Ilk TRANE® Heater Pressure Drop Table TEM Air Handler Models Number of Racks Heater Racks Airflow 1 2 3 4 Heater Model No.of Racks CFM Air Pressure Drop-Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR3510 3 1400 0.02 0.04 0.06 0.12 BAYHTR1515 3 1300 0.02 0.04 0.05 0.11 BAYHTR3515 3 1200 0.01 0.04 0.05 0.10 BAYHTR1519 4 1100 0.01 0.03 0.05 0.09 BAYHTR1520 4 1000 0.01 0.03 0.04 0.09 BAYHTR1521 4 900 0.01 0.03 0.04 0.08 800 0.01 0.03 700 0.01 0.02 600 0.01 0.02 4 TEM4A0C42-SUB-1A-EN tak TRANS` Performance and Electrical Data 1. See Product Data or Air Handler nameplate forapproved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 1. Air Flow Performance TEM4AOC42541SA(a) EXTERNAL STATIC AIRFLOW (In w.g) Speed Taps—208-230 VOLTS High Med Low t 0.1 1623 1509 1403 0.2 1583 1465 1357 0.3 1539 1420 1309 0.4 1494 1373 1260 0.5 1450 1356 1211 0.6 1399 1276 1159 0.7 1353 1223 1102 1. Values are with wet coil,no filter,and no heaters 2. CFM Correction for dry coil=Add 3% 3. t=Factory setting 4. Low=Tap 1-3,Med=Tap 4,HIgh=Tap 5 (0) For the TEM4A0C42S41SA in downflow applications,airflow must not exceed 1600 cfm due to condensate blow off,. TE M4A0C42SU B-1 A-E N 5 0 TRANE Performance and Electrical Data Table 2. Electrical Data TEM4AOC42S41SA 240 Volt 208 Volt No.of Capacity Capacity Mini- Heater Maximum Heater Heater Model No. Circuits/ - - Minimum mum Maximum Phases Amps Circuit Overload Amps Circuit Overload kW BTUH Circuit Ampacity Ptionc kW BTUH Ci rcuit Ampaci- Protection ty No Heater 4.1* 5 15 4.1* 5 15 BAYHTR1504BRK BAYHTR1504PDC 1/1 3.84 13100 16.0 25 25 2.88 9800 13.8 22 25 BAYHTR1504LUG BAYHTR1505BRK BAYHTR1505PDC 1/1 4.8 16400 20.0 30 30 3.6 12300 17.3 27 25 BAYHTR1505LUG BAYHTR1508BRK BAYHTR1508PDC 1/1 7.68 26200 32.0 45 45 5.76 19700 27.7 40 40 BAYHTR1508LUG BAYHTR151OBRK BAYHTR151OPDC 1/1 9.6 32800 40.0 55 60 7.2 24600 34.6 49 50 BAYHTR1510LUG BAYHTR1515BRK- 9.6 32800 40.0 55 60 7.2 24600 34.6 48 50 Circuit 1(a) 2/1 BAYHTR 15156RK- 4.8 16400 20.0 25 25 3.6 12300 17.3 22 25 Circuit 2 BAYHTR1520BRK- 9.6 32800 40.0 55 60 7.2 24600 34.6 48 50 Circuit 1 2/1 BAYHTR15206RK- 9.6 32800 40.0 50 50 7.2 24600 34.6 43 45 Circuit 2 BAYHTR3510LUG 1/3 9.6 32800 23.1 33 35 7.2 24600 20.0 30 30 BAYHTR3515LUG 1/3 14.4 49200 34.6 48 50 10.8 36900 30.0 42 45 BAYHTR1515BRK with single circuit 1/1 14.4 49100 60.0 83 90 10.8 36900 51.9 73 80 power source kit BAYSPEKT201A BAYHTR1520BRK with single circuit 1/1 19.2 65500 80.0 108 110 14.4 49100 69.2 94 100 power source kit BAYSPEKT201A *=Motor Amps (a) MCA and MOP for circuit 1 contains the motor amps. 6 TEM 4A0C42-SUB-1 A-EN TRANS' Features and Benefits • Painted metal cabinet with captured foil face • Draw Through Design insulation • Horizontal Drain pan • 2%or less air leakage • Single Color • R-4.2 Insulating Value • Fused 24V Power • Multi-Position UP/Down Flow,Horizontal Left/Right • 1 year warranty • ALL Aluminum Coil with Enhanced Patented Coil • 10-year warranty registered Fin • Electric Heaters with polarized plug connections • Optional extended warranty available (sold as accessory) Important:Condensate management kit is required for • R-410A Thermal Expansion Valve all 5 ton air handler models installed in • ECM Motor(3.5-5 Ton Models) downflowapplications. • Low Voltage Pigtail Connections ti.�i CERTIFIED,., CERTIFIED,„ �Tt C www.ahr.direclory.org C www.anrldirectory.org �V Unitary Small AC Unitary Small HP C US AHRI Standard 210/240 AHRI Standard 210/240 CO US mnmmeeempmesyvem mnmuen.+emunmry..n,n m.mmo¢:.wnan sm,mmwnxe�. �.�=a::�mn•,. Intertek TRANES Trane optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand,the leader in creating and sustaining safe,comfortable and energy efficient environments,Trane offers a broad portfolio of advanced controls and HVAC systems,comprehensive building services,and parts.For more information,visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. ©2014 Trane / TEM4A0C42-SUB-IA-EN 09 Jul2014 Supersedes TEM4AOC42-SUB-I-EN (June 2014) 11 Ingersoll Rand . . • TRANER' 4TWR4036D-SUB-1 TAG: SUBMITTAL NOTE:All dimensions are in mm/inches. 3 Ton Split System Heat Pump — 1 Phase r 4TWR4036D ,4j 4.. Product Specifications �� :-� ``� '�� OUTDOOR UNIT®® 4TWR4036D1000A i� a�• `�1p•R t POWER CONNS.-V/PH/HZ® 208/230/1/60 c . �` t t MIN.BRCH.CIR.AMPACITY 22 SERVICE PANEL ' �3 �rl�fR, l BR.CIR.PROT.RTG.–MAX.(AMPS) 35 ELECTRICALCAND REFRIGERANT ..�� �/, �V/%. COMPRESSOR CLIMATUFF°-SCROLL PER PREVAILING CODES. ,• : ✓�j�' NO.USED-NO.SPEEDS 1 -`m '8' ' VOLTS/PH/HZ 208/230/1/60 R.L.AMPS CO -L.R.AMPS 16.7-79 . �. FACTORY INSTALLED START COMPONENTS®a NO TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1521 15 FEET/ INSULATION/SOUND BLANKET NO ABOVE UNIT.UNIT SHOULD RE PLACED SO RODE RUN-OFF RATER DOES NOT POUR DIRECTLY ON UNIT.AND SHOULD BE AT LEAST 305 112'1 FROM WALL AND ALL COMPRESSOR HEAT NO SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. _ OUTDOOR FAN PROPELLER r DIA.(IN.)-NO.USED 27.5-1 15I∎R >_ RfaM TYPE DRIVE-NO.SPEEDS DIRECT-1 ELECTRICAL SERVICE I 1 CFNO.M td MOTORS 0.0 IN.-W.G.HP 0 4385 PANEL -1/5 MOTOR SPEED R.P.M. 850 K VOLTS/PH/HZ 200/230/1/60 II F.L.AMPS 0.95 E1a1 OUTDOOR COIL—TYPE SPINE FIN", B5 TIE A ROWS-F.P.I. 1 -24 j� 1 I i FACE AREA(SO.FT.) 22 1 TUBE SIZE(IN.) 3/8 22.2 IOW PIA. HOLE LOW VOLTAGE I REFRIGERANT 20.611-EAe1DIA. LBS.—R-410A(O.D.UNIT)® 6 LBS.-2OZ. 72.2 tI/SI DIA. lAj''� FACTORY SUPPLIED YES NOTE IN CONICAL RP iI BOX BOTTOU FOR ELERRICAL H `'.,r LINE SIZE-IN.O.D.GAS® 3/4 POKER SUPPLY F I — aililn�w_��iwii LINE SIZE-IN.O.D.LIQ.© 3/8 5.0. FOR ALTERNATE ELECTRICAL ROUTING CHARGING SPECIFICATION J I AS LINE IZ4 TURN BALL SERVICE VALVE. 'D' L IOU ID LIRE SERVICE VALVE. F IA.FEMALE BRAZED CONNECTION WITH IRA•SAE SU BCOOLI NG 8°F F• N WITH BRAZE I FLARE PRESSURE TAP FITTING. DIMENSIONS H X W X D 'E' I.D.I.DRES PRESSURE BRAZ SAE FLARE PRESSURE TAP FITTINGS. CRATED(IN.) 38.4 x 35.1 x 38.7 14:P WEIGHT f.:ii SHIPPING(LBS.) 229 H 1:x.;1 10U10 LINE SERVICE NET(LBS.) 198 F �Ilr VALVE. •E' I.O. FEMALE IIMIMM% BRAZES CONNECTION WITH IRE'SAE FLARE 01■I^" PRESSURE TAP FITTING. AS LINE SERVICE VALVE. •0' 1.0.FEMALE BRAZED 0 Certified in accedence VASE the Air-Source Unitary ArCAnditioner Equipment certificaEOn program,which CONNECTION•TN ITV is based on AHRI standard 2101270. J SAE ILAME PRESSURE TAP Q Rated in accordance with AHRI standard 270. IF FITTING. O Calculated in accordance Dry il with Noll.Elec.Codes.Use only HACK circuit breakers or loses. 0 Standard Air—Dry Coil—Outdoor H&.Z O This value approximate.For more precise value see unit nameplate. 0 Max.linear length 60 I.;Max.lilt-Suction 60 5.;Max lilt-Liqu d 90 ft. For greater length consul refrigerant piping software Pub.No.32-3312-0' (•denotes latest revision). MODELS BASE A e C 0 E F D Al K O This value shown for compressor RLA on the unit nameplate and on Iris spedfication sheet is used to compute minimum branch circuit smpaotyand macluse size.The value shown is the branch circuit selection - • current. 841 948 870 98 219 86 47WF140360 a )33 137.1/4) (aa al 3/4 3B t 5z(el (3-7/01 Iasla) la-aal sae ion 0O No means no start components.Yes means quick start kit components PTC means positive temperature coefficient starter. Sound Power Level A-Weighted Full Octave Sound Power[dB] Model Sound Power Level [dB(A)] 63 Hz 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR4036D 76 84 75 70 72 67 62 57 50 Note:Rated in accordance with AHRI Standard 270-2008 ©2014 Trane Mechanical Specification Options General Condenser Coil The 4TWR4 is fully charged from the The outdoor coil provides low airflow factory for up to 15 feet of piping.This resistance and efficient heat transfer. unit is designed to operate at outdoor The coil is protected on all four sides by ambient temperatures as high as 115°F. louvered panels. Cooling capacities are matched with Low Ambient Cooling a wide selection of air handlers and As manufactured,this unit has a cooling furnace coils that are AHRI certified.The capability to 55°F.The addition of an unit is certified to UL 1995.Exterior is evaporator defrost control with TXV designed for outdoor application. permits low ambient cooling to 20°F. Casing Accessories Unit casing is constructed of heavy Thermostats—Cooling only and gauge, G90 galvanized steel and heat/cooling (manual and automatic painted with a weather-resistant powder changeover).Sub-base to match paint on fan top cover and louvered thermostat and locking thermostat cover. panels, prepaint on all other panels. Corrosion and weatherproof CMBP-G30 base. Refrigerant Controls Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. A factory installed liquid line drier is standard. Compressor The compressor features internal over temperature and pressure protection and total dipped hermetic motor.Other features include:centrifugal oil pump and low vibration and noise. 011.1i1111111 CERTIFIED,. �I� us Q www.aM1ritlirectary.orq Unitary Small HP AHHI Standad 210/240 trsre° C,rIAIP1114naopri @ mJ/wncii mwcciopi.wy.c,iii Is IISItJ wI['.i PHlll. Intertek TRAMS. 07/14 Trane www.trane.com Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice. FOR: MIXING BOXES FOR TRANE aCanFab 2/4TED3F*** AIR HANDLERS CANNON FABRICATION INC '.,. 182 GRANITE STREET, SUITE 101. CORONA. CA 92879 PHCNE:(951)278-1830 FAX:(951)278-8444 www-caNab.com eanfabOconfab._om PART NO: 6433-MB** BACK & TOP OR BOTTOM MIXING BOXES FEATURES 1 - FULLY MODULATING HONEYWELL CONTROL SYSTEM AVAILABLE WITH DRYBULB, SINGLE ENTHALPY OR COMPARATIVE (DIFFERENTIAL) ENTHALPY SENSOR(S) AND HONEYWELL OR BEUMO ACTUATOR. SEE MODEL NUMBER BREAK DOWN BELOW. 2 - HEAVY GAUGE STEEL CONSTRUCTION WITH GALVANIZED FINISH. 3 - RETURN AIR AND OUTSIDE AIR DAMPERS ARE THE SAME SIZE. RETURN AIR SHOWN OPEN, OUTSIDE AIR SHOWN CLOSED AND ACCESS PANEL AS SHOWN. SEE MODEL NUMBER BREAK DOWN BELOW FOR OTHER OPTIONS. 4 - 1"-1.5 LB. DENSITY INTERNAL INSULATION. CANFAB# TRANE MODEL 6433-M801 2/4TEC3F18A/ 47 LBS. 24A/30A/36A RETURN AIR DAMPER 6433-MB02 2/4TEC3F42A/ WITH 1" FLANGES 54 LBS. *NOTE* gyp.FOR FOR INDOOR / 25 USE ONLY �p 1 e^"Ns 411 ACCESS PANEL LLI . OUTSIOE AIR DAMPER BOTH SIDES /� WITH 1" FLANGES PART NUMBER A B C D E 6433-MB01-TP-8K-## 18.0625 19.5 19.5 15.5 14 6433-MB02-TP-BK-## 18.0625 21.5 21.5 18.5 15 II CONTROLS (C-COMPARATIVE ENTHALPY, D-ORYBULB, E-ENTHALPY, N-NONE) ACTUATOR (B-BELIMO, H-HONEYWELL, N-NONE) OUTSIDE AIR DAMPER POSITION (BK-BACK, LE-LEFT, RI-RIGHT) RETURN AIR DAMPER POSITION (BK-BACK, LE-LEFT, RI-RIGHT) DOC: 01-01 PROJECT: DATE: ENGINEER: DISTRIBUTOR: DRAWING NUMBER: 6433tr.dwg rb/SB 04.04.08 Printed Date: 4/22/2015 ®GREENHECK Job: JO Printed - CenturyLink Quilcene Building Value in Air. Mark: OSA Louver Internal View ;' ESD-435 I/ 4 in. Frame, 35 deg Blade Application & Design ESD-435 is a weather louver designed to protect air intake and exhaust it openings in building exterior walls.Design incorporates drain gutters in the head I/ member and horizontal blades to channel water to the jambs where water is further channeled through vertical downspouts and out at the sloped sill. The ESD-435 is an extremely efficient louver with AMCA LICENSED �I/ PERFORMANCE DATA enabling designers to select and apply with confidence. II/ Width and Height furnished approximately 0.250 in.under size. Construction Features Frame Depth(in.): 4 Frame Thickness(in.): 0.081 Louver Material: Aluminum Frame Type: Channel Sizing: Nominal Fixed Blade Thick.(in.): 0.081 Shape: Rectangular Welded Construction: No Options and Accessories Finish Louver Finish Type: Mill BirdScreen Bird Screen: Internal Bird Screen Matz: Aluminum Bird Screen Type: 3/4x0.050 Flat Exp. Bird Screen Finish: Mill Warranty Product Warranty: 1 Yr(Standard) Summary ID# Tag Qty. W(in.) H(in.) Free Area(ft2) Sect.Wide Sect.High Sect.Ship 1-1 1 18.000 24.000 1.3 1 1 1 Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck. Unless specifically indicated,the following are NOT included in the quote provided: structural steel, installation hardware(anchors, angle clips, continuous angles,shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation.miscellaneous flashing,trim or enclosures.blank off panels,mullion covers or mullion hardware,hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals,any applicable taxes,stamped and sealed structural calculations seismic calculations or job specific engineered submittal drawings. • CAPS 4.17.1420 Z:1Daniel T\Winjobs1JOH-CenturyLink Quilcene.gfcj Page 1 of 6 Printed Date: 4/22/2015 GREENHECK Job: JO Printed - CenturyLink Quilcene Building Value in Air. Mark: 24x16 Relief Louver Internal View ;' ESD-435 4 in. Frame, 35 deg Blade 11/ Application & Design ESD-435 is a weather louver designed to protect air intake and exhaust Iopenings in building exterior walls. Design incorporates drain gutters in the head member and horizontal blades to channel water to the jambs where water is �/ further channeled through vertical doWnspouts and out at the sloped sill. The IESD-435 is an extremely efficient louver with AMCA LICENSED I/ PERFORMANCE DATA enabling designers to select and apply with confidence. I/ j i. Width and Height furnished approximately 0.250 in.under size. Construction Features Frame Depth(in.): 4 Frame Thickness(in.): 0.081 Louver Material: Aluminum Frame Type: Channel Sizing: Nominal Fixed Blade Thick.(in.): 0.081 Shape: Rectangular Welded Construction: No Options and Accessories Finish Louver Finish Type: Mill BirdScreen Bird Screen: Internal Bird Screen Mat!: Aluminum Bird Screen Type: 3/4x0.050 Flat Exp. Bird Screen Finish: Mill • Warranty Product Warranty: 1 Yr(Standard) Summary ID# Tag Qty. W(in.) H (in.) Free Area(ft2) Sect.Wide Sect. High Sect.Ship 2-1 1 18.000 24.000 1.3 1 1 1 Larger openings may require field assembly of multiple louver panels to make up the overall opening size.Individual louver panels are designed to withstand windloads up to a maximum of 25 PSF(size and configuration dependent).Design,materials and installation of structural reinforcement required to adequately support large sections or multiple section assemblies within a large opening are not provided by Greenheck. Unless specifically indicated, the following are NOT included in the quote provided:structural steel, installation hardware(anchors, angle dips. continuous angles,shims,fasteners,inserts,backer rod and sealant),field measuring and/or installation,miscellaneous flashing,trim or enclosures,blank off panels,mullion covers or mullion hardware,hinged frames or removable subframes,custom bird/insect screen,3-coat,metallic and/or exotic paint finishes,bituminous paints for unlike metals,any applicable taxes,stamped and sealed structural calculations seismic calculations or job speck engineered submittal drawings. CAPS 4.17.1420 Z:1Daniel T1Winjobs\JOH-CenturyLink Quilcene.gfcj Page 3 of 6 Printed Date: 4/22/2015 ®GREENHECK Job: JOH - Century Link Quilcene Building Value in Air. Mark: MOD for 24x16 Relief Louver VCD-23 Low Leakage Control Damper f''''Illo '� Application& Design The VCD-23 is a ruggedly built low leakage control damper intended for H 1111100, i` application in low to medium pressure and velocity systems. A wide range of 'r• electric and pneumatic actuators are available. C, E RATINGS ► 11 41 5 in.wg Velocity:3,000 ft/min i•-■. 1L■, Leakage:Class 1A©1 in.wg,Class 1 rc�up to 5 in.wg. ..<I V 1^ I�; �1Max. .....\ r. 1 W II Y DRIVE SIDE Notes: All dimensions shown are in units of inches. W&H furnished approximately 0.25 in.undersized and only refer to damper dimensions(sleeve thickness is not included). Electrical accessory wiring terminates at the accessory. Field wiring is required to individual components. ramca Maximum velocity is based upon damper width. WORLDWIDE OERTIr1ED MIRES Installation instructions available at www.greenheck.com. AIR IMAGE CONSTRUCTION FEATURES D PEmOR uIR Blade Action: Opposed Actuator Type: 24 VAC ! n'n ,,,, menmmn Frame Type: Channel Actuator Mount: Internal MCMIM n';\ mroamion Material: Galvanized Actuator Location: Left Side nE n*mom n Axle Material: Steel Fall Position: Closed Axle Bearings: Synthetic Cycle: 60 Cycle Linkage Material: Steel Jackshafting: No Preference Blade Seal: TPE Temp.Rating(F): 180 Jamb Seal Mat.: 304 SS NEMA Enclosure: Least Cost Sizing: Nominal Actuator Sizing: Default SqFt Frame Thickness(ga): 16 ID# Tag Qty W(in.) H(In.) Drive Arr. Actuator Act. Qty. 3-1 1 24.000 16.000 Drive-CC-11-1F IL-0 TFB24-SR 1 CAPS 4.17.1420 Z:1Daniel TtWinjobs\JOH-CenturyLink Quilcene.gfcj Page 5 of 6 Printed Date: 4/22/2015 wGREENHECK Job: JOH - CenturyLink Quilcene Building Value in Air. Damper Drive Arrangements Job Summary -Start- Drive Arrangement: Drive-CC-11-1 FIL-0 Damper Drive Arrangements Job Summary -End- CAPS 4.17.1420 Z:10aniel T\Wnjobs\JOH-CenturyLink Quilcene.gfcj Page 6 of 6