HomeMy WebLinkAboutSEP2015-00062 Jefferson County Department of Community Development 621 Sheridan St., Port Townsend WA 98368, (360)379-4450 SEPTIC PERMIT APPLICATION ;+T,. PROPERTY OWNER George Seifert I "dry MAILING ADDRESS 449 Suzanne Avenue " ,77•• Suzanne l Martin '•," + Shoreview, MN 55126 �` nK 'e PHONE ( 651 ) 481-1639 SYSTEM DESIGNER Suzanne Martin Designer Phone# 990-3304 LEGAL DESCRIPTION: Section 27 Township 30N Range 1W PARCEL# 965 000 302 Subdivision Name Kala Point#8 Division Block Lot(s) 402 ((�� Site address/Directions to site Northwest Corner of Pinecrest&Kala Point Drive \'1 1 a e& P r\`-1 r-\(� SOURCE OF SEWAGE/USE TYPE OF WORK WATER SOURCE Residential V _ New V Tank/s only Private Residential ADU Modification_ — Public V Commercial__ Expansion_ Community Upgrade Repair SITE SIZE +/-21591sf SYSTEM TYPE Partial Repair-(tank) (drainfield) Previous Evaluation Conventional ✓ Designate RPsPrve Area Yes# SEP05-00183 Alternative Redesign No SYSTEM DETAILS Number of Gallons/day 360 Soil type 4 (attach soil eval.) Application Rate 0.60 gal./sq.ft./day Drainfield Length 200 ft. Trench Width 3 ft. Trench/Bed Depth 12-24 in. Septic Tank size 1000 gal. Pump Chamber size n/a gal. TYPE OF Conventional Trench system By signing the application form, the applicant/owner attests that the information provided herein is true and correct to the best of their knowledge. Any material falsehood or any omission of a material fact made by the applicant/owner with respect to this application packet may result in this permit being null and void. I further agree to save, indemnify and hold harmless Jefferson County against all liabilities,judgments, court costs, reasonable attorney's fees and expenses which may in any way accrue against Jefferson County as a result of or in consequence of the granting of this permit. I further agree to provide access and right of entry to Jefferson County and its employees, representatives or agents for the sole purpose of application review and any required later inspections. Staffs access and right of entry will be assumed unless the applicant informs the County in writing at the time of the application that he or she requires prior notice. Inspections shall occur during regular business hours. Initial here if you require notification before entry Appeal—A person aggrieved of a decision of the Health Officer may appeal. Appeals shall be submitted to the Health Division in writing within fifteen days after receiving written notice of the decision. DISCLAIMER-This application is for an on-site sewage system that meets the state and county standards in effect on the date of application. This application for an onsite sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. 9_ C l�/yam//S Pro rty Owner Signature Date FOR OFFICE USE ONLY (" 0 PARTIAL 7/1/1.S ASBUILT I•QCt�4 l�/Ir FINAL 101``J +' ' AP""OV D INSP/PUMP TEST 6 �a'i 1 ALL HOLD REQ. MET --)44) `{/ Co 69 Date/I I 1 eee 5 a1 nae MRie # Aa��=Y/ /Chec yang ^ne\8 alse#BEsPn�Ca; nkt\ 2_ e•\Bo^^rants and y daffCQ forms\Suz\2008 SPA.DOC -- JEFFERSON COUNTY PUBLIC HEALTH 615 Sheridan Street•Port Townsend•Washington •98368 www.jeffersoncountypublichealth.org Phone .360-Jo5-Y444 Fax :3ti0-3f9=448( ON-SITE SEWAGE DISPOSAL PERMIT PERMIT #: SEP15-00062 Date Received: 05/11/15 SITE ADDRESS: 1717 KALA POINT DR Date Issued: 06/30/15 Date Expires: 06/30/18 APPLICANT: GEORGE SEIFERT PHONE: 449 SUZANNE AVE SHOREVIEW MN 55126-2312 LEGAL DESCRIPTION: KALA POINT#8 LOT 402 PARCEL#: 965000302 Section: 27 Township: 30N Range: 1W DESIGNER: SUZANNE L MARTIN PHONE: 360-554-0224 PO BOX 125 CHIMACUM WA 98325 SYSTEM DESCRIPTION: CONVENTIONAL TRENCH No. of Gallons per Day: 360 Type of work: NEW Drainfield Trench Septic Tank Length: 200 feet Width: 3 feet Depth: 12 inches Size: 1,000 gallons DISCLAIMER-This approval is for an on-site sewage system that meets the state and county standards in effect on the date of application. This approval for an on-site sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. All construction and development activities must comply with all permit conditions, state and local codes, and Recommended Standards and Guidance documents in effect when the permit is issued. The property owner is responsible for the accurate location of all property lines.Any removal of or major disturbance of soil in the primary or reserve drainfield area may create site conditions that are unacceptable for the installation of a sewage disposal system. Any change in drainfield or tank location may invalidate this permit unless prior approval is obtained from the Jefferson County Environmental Health Division. If during excavation or development of the site an area of potential archeological significance is uncovered, all activity in the immediate area shall be halted,and the UDC Administrator shall be notified at once. Permit issued to CONSTRUCT, ALTER, REPAIR OR MODIFY AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM IN JEFFERSON COUNTY, WASHINGTON This permit is issued for a period of three years (unless otherwise stated above) in accordance with Jefferson County Rules and Regulations for On-Site Sewage Systems, codified in JCC 8.15 as amended. This permit may not be renewed. / " Jefferson County En 'ronmental Health Specialist This permit with conditions must be onsite during all phases of construction HEALTH DEPARTMENT MUST BE CONTACTED FOR FINAL INSPECTION. SPECIAL CONDITIONS APPLY - SEE ADDITIONAL PAGES CONDITIONS OF APPROVAL - PERMIT NO.: SEP15-00062 1.) Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application. 2.) Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box. 3.) H - AS PER WAC 246-272AAND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272AAND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT 4.) Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS. 5.) Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start. 6.) H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval. 7.) Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system. 8.) 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components. 9.) Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site. 10.) The project shall adhere to the Best Management Practices (BMPs) to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 11.) All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued. SEP15-00062 Page 2 of 2 \\tidemark\data\forms\F SEP_Permitmod.rpt 6/30/2015 CONVENTIONAL SYSTEM AS-BUILT INSPECTION REPORT 4(D5 000 3Oa Installer: Shold Excavating(AJ Sukert) Parcel # 965 X00 302 Permit Owner: George Seifert Permit# SEP15-00062 Designer: Suzanne Martin Design Flow: 360 gpd Site Address: 1717 Kala Point Drive-Port Townsend,WA 98368 ABSORPTION AREA: DRAINFIELD TRENCH WIDTH TRENCH DEPTH TANK SIZE #OF BEDRMS #GAUDAY LENGTH 201 3' 24 1000 gal 3 360gpd IF PUMP AND PUMP CHAMBER REQUIRED: Shroud/Screen Tank Size: n/a Float Arrangement High water float—distance to top of tank/emergency storage Dose drawdown (#of inches) #Gallons/Dose Timer/Dose Counter info Pump Size/Manufacturer COMMENTS (inspection notes, changes from design or deficiencies installation)Attach additional sheet(s) if necessary Cotton septic tank was installed with risers and outlet filter distribution box was installed with riser and speed leveller construction of this system meets current county and state code, regulation and recommended standard and guidance Users Manual Provided to Homeowner mailed 27 August 15 Date ATTACH ASBUILT DRAWING signed by Designer or stamped/signed by a Licensed Professional Engineer I CERTIFY THE INFORMATION PROVIDED ABOVE WAS VERIFIED BY INSPECTION, THE SYSTEM WAS INSTALLED AS DESIGNED AND APPROVED by JEFFERSON COUNTY (DATE) OR THAT CHANGES HAVE BEEN NOTED AND THIS SYSTEM IS IN COMPLIANCE WITH WAC 346-272 27 August 2015 5100342 Designer ignature Date License# 4. Cllr f . Suzanne L Martin .;lir EXP1 ES env„ z o 5. ' c 5• ' O I 107.0' h v 1111":416-"•`...74:47,14-4.17,711-411111'‘,..1 4111111111101cD - fn - „ 0, { (...n CD 0 ro I • • �K �N N 5,1- n \/ o::F:::::;:;;: , may : _ �' _ _ \ pp XI c-- \ i v s N °' N , li cn n! <, CD wCD F /c co 10, � o Q 'Cb 7 • = CD p _ (D _ h - N CD . a> as /X -. p O n = 0, Cu CD < 0- 0 ' I = N CD p h p c- n CD 1 N * , p CD c < N Q CD CD `-`• N.4 i CD .--f c * -5 -5 cry CD N fD h c, 4+ o CD Q ' 2 0, _ I c a N p CD CD c �+ o C � nh s , O0 CD N c O, N (/� cp ' 0, CO N px CO 0 .+ 0 0, N 3 -1- c„, + ,. N ' `G c o cu C b 3 p. CD 4 cn 0, n ' Q m i,'' CD ; vii d R'•' SD p CSD i 4 , 4 ` •46"E 80.60' o `� o ocno I a) ,.+ c+ 0 I N CD Cb 0 0 c- x , (j) < — 0, 0, < ITl (0 • I N -1 r+ CD + 7t alal � vm G7 CD .-I- _x -I— i II O 4..,, m u, W ' -0m o ° o rn et) O c 91 a m I m TI co o � v � m o) o •* a m 01 -0 a) 0 Q .� CD 4-1- St * CD _.o a ca c a aoa o ci, co N C) 41- I,.., CD C) ° B o CD (=, m� m (D r+ 2n Li n g CD mom -I p amm -< (n SCD 0 I Op WtUa F warn _ co p, d O .-1- •• co O x C) w o m -th -. V`i.i'il;�i.�- ----, ,-4-I -3 -,I d O < -< A A c •••I (D(0 - N 1) .',i �i`�.. i -. CD CD 0 _ CD it li 3 A -4 0 0 CD N C.) N a° \ 7c' ' 003E3 0 0 0 0 0 0 0 0 0 l o 3 �, Q d -. CD r+ D, 3 O II < (D coN N W CD O • -7 rr r,-00 -• C- O 3 N CD a a CD I° o c c o o c o o u o a, 0 co a, p p O O = CIS c S m (C (DCD � r+ • �, ? a xi ;•�. i ' . r.0 CD - a .{ '0pom °• . .\' N T N dNQ n 7 m a m n ;�.i1;AiV _+, Cl.OQ p p Cl) h -, '6CDo : � t� N" Q1 - CD 1 L N noi°;�iQi`Air+-0 = -7 0. ,-1- p n - wD .3 -0.(D 0, O CD CCO N -4. = c- r+ ( D * 00 67 57 a C13 C -,. N,„,NI° 25'46"E 107.0' < hu- I 3 \ 11 (o D- Q ( �� • I CD ...< c CL n -' v, i grkb t All 4 ry p n N J C . rs cI a W te^ x CD 0I - aa. I Ai:1 0 f♦ 1 I CD o) -• 0 lo ------- TOP AC POPP. C=7.CI)0)0 -6 - 0_ ,-+ = CD m ANo 0 3 C) /` 1 C� �' I 4-1--0 a+ O zn4 I * x83(0 8 > % p -)` I p, CD 0 0 D CD m i ° Z c j I 0 p n r+ co g n'm (f) co / co 0iv es. 0 '1 ' r-h C C-I-I- m maQ S) a CD r+ A coNco — I r I O, 177 .- m g d -, p � � Q o m a� ° p 3 = _ 3 W D •C '' N-r ►�oo I r+ r~ CO0, ° A CD Nn o I B o I •CDCn- CD C r+ 3 o 0 CD I Q '. 0) CCD p p-1- I CSD N X. 3 \ 0til C� rF cn� x CD + v •• (n (D Cu CD CD CD 3 fT] b -, + c- CD 111 =' CD (1 o . n \t7( Dom to /9 CD -is CD CD A ' � nJ V) yN o a 3 O O ' r° i I Qa a o O w co °Q \ P �O it) I C Q CZ D M rF 0. kfoll 0 1 CL = P 8- a" —I (11 o I ' Jr t � . '_�-_ �� n (gyp o•- n ap(fc * N I° 25'46"E 80.60' I 3 CD o(°o c� °' • C I o 3 EP m o ' 1 to 3 a CD --�o =�_�,o - -______RIBELRESI RVE II o°� mc CDoo � � yr+ r+ x (n CL U1- c . u) 33o -< CD . ) m r B < o i �,' — = '-} O co m- 5 i y' 0) O N '- I 0 D) a� m m m i,4h� A , Ins;u,x$ 0 .-4-4.,v 'R'r,,� v O , O , , O6- , , (D a) O_ O I o Cr r CD -1 , 0 D�j a Q , v 0 - co�+c sem N -. CD CD O _ CD FIT ° [D (n N w 0b . ..1:--:, O - • (n 0 a 2 - O 'o N • N 0 - (n CO , ,� . * ,7,• 0, << n, m -1- •=t0) ° —. 11) '• most = m, n) %,'' - in slim cr a I0m P- < j r O m - .. vi o PD' 5.• • in o c 0Z _= c' cu °: 5. m6 m a) a o m o CD -A.- x Am -10 , — m -1 0 Z * w o (o = �) o o' • m o D -0 N..< 3 N o D (Q 3 0 CD o °x 0 0 -oo mal ocn � o � °) `< o m a, ° (DR. * Q. �' CC) ' O v n - ° C� mN (n O O d ON V N ° , u0, o' - o. •'c N - ti •• S(C) C O y CD a - N 0 CD (D 0 c m (D '�' 1l N 0 D� d 0 0 0 r- oaC � ° * � * o `< o nm- tl CC N-� m ? pv - v (o v O ° aa � ° n n' w W(n * C � � 0 3 a ) , KCo IHE mm4m- mo -O m 0to o C 'co 0-� 0 N Fr; 0 D c �30N . O � v Q � o D o to m H° aNpcO � a < a 5 � 43 m WN CC < O -.• NO m OD 3 W a p a 3 • 8: tg CO ELI 0 tl, 0 S N —I V 0 a V 0 CD . c o a • w Sop Coi zO < w m a fD a N oa .3 ° co N � c C 0 g O CDK 'a_ CU w 3 d � c ®� � o °° - v 3 S Q° 0, m 0) zr• m n- v m ss O `i c -' ;U co o N 0 N 0) 91, o • mss m (n 0o a Sao 3 00 w Page 5 of 5;Seifert; Tank Cross Section - Not To Scale parcel#965 000 302 (For illustrative purposes only, actual tank configuration may vary, tanks must be on list of approved products.) SECURED LID WITH GAS TIGHT SEAL 1 \If ACCESS RISER .SII g. l FI JSH;GRADE I — distribution box FROM SEWAGE SOURCE FLOATING MAT APPROVED EFFLUENT FILTER SEDIMENTS maximum 3/16"filter SEPTIC TANK (TYPICAL) GE DISPOSAL DES1Gt s fir G cpactio rt A. rove ate V'2cd� IOC J j •""` "- .",.1 1 vv-3y2;i +'G YM` nPtru cC 9 t,5 aeo 3oz 41?(<4..Jefferson County Environmental Health Dept. 615 Sheridan St.,Port Townsend,WA 98368 SOIL EVALUATION �'P Property Owner- Mike and Lynn Davenport °� S°I> '41s System Designer- Soils Applications Inc.Ken Warren ° �d tie LEGAL DESCRIPTION: Section-_27 Township-30N Range-1W Parcel#965000302 Subdivision: Kala Point#8 Division- Block Lot(s)-402 Date Logged: 05/05/05Logged by: Ken Warren Include soil textural characteristics and depths at which significant changes occur. Be sure to include depth where mottling or impermeable layers occur. SOIL LOG#1 ,/&477 -3" to 0"in. : Duff 0" to 11"in :Loamy Fine Sand 11" to 28"in :Moderate Compact Fine Sand 28" to 60"in :Fine Sand/Medium Sand,Slightly Compact �� /Anticipated water table in. Roots to 41"inches. 19) Health Dept.Comments 0.;\ SOIL LOG#2 -4" to 0"in. : Duff4k • 0" to 10"in :Loamy Fine Sand 10" to 60"in :Fine Sand/Medium Sand,Sligh Compact ' Anticipated water table in. Roots to 49"inches. 0 Health Dept. Comments SOIL LOG#3 0" to 12"in. :Loamy Fine Sand 12" to 36"in : Fine Sand 36" to 60"in : Moderately Compact,Fine Sand/Medi and Anticipated water table"in. Roots to 64"inches. Health Dept.Comments scir2aE'55E1 /6r�oFb YC„e - b5 c5CxD 3o a Jefferson County Environmental Health Dept. 615 Sheridan St.,Port Townsend,WA 98368 SOIL LOG#4 -3" to 0"in. : Duff 0" to 62'in :Moderately Compact Fine Sand,Medium Sand Pockets Anticipated water table"in. Roots to 46"inches. f1`_ 11 yak;•y},7• ` Yv .r c,.