Loading...
HomeMy WebLinkAboutBLD2011-001021 VERIZON WIRELESS PROJECT AREA SEE SH E7ET A7-27.0\ (E) PROPERTY LINE OVERALL SITE PLAN ERTY LINE mf%Tg:-Q- 1. SITE PLAN IS DERIVED FROM: EXISTING DRAWINGS, GIS, AERIAL IMAGES AND SITE PHOTOS. 2. PROPERTY BOUNDARIES AND TRUE NORTH ARE APPROXIMATE AND DERIVED FROM GIS DATA. DRAWING LEGEND N W ---s SUBJECT PROPERTY LINE DESCRIPTION ADJACENT PROPERTY LINE 01-17-11 LEASE AREA 90% REVIEW ACCESS EASEMENT CF COAX/FIBER ROUTE COAX COAX ROUTE F FIBER ROUTE P POWER ROUTE TELCO TELCO ROUTE P/T POWER/TELCO ROUTE OH OVERHEAD UTILITY ROUTE E E EXISTING ELECTRICAL -x-X-x- EXISTING FENCE YAX ' X �-�X-x ELEVATION MARKER y ^X � X-X.X u SECTION MARKER COMMON ABBREVIATIONS (E) EXISTING (P) PROPOSED (N) NEW (NP) TYPICAL TARBOO LAKE ROAD SCALE: 1" = 800'-0" (11 Xl 7) SCALE: 1" = 400'-0" (22X34) of 4001 �oom 16001 ?m 8760122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 Ecp , I - 7-'-t -1 '1 - APR 2 " 2011 CPM PROJECT NO.: 3649 m PRELIMINARY N W ---s E DESCRIPTION S 16001 ?m 8760122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 Ecp , I - 7-'-t -1 '1 - APR 2 " 2011 CPM PROJECT NO.: 3649 m PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 MH/CT 90% REVIEW 4 04-11-10 H/CT CLIENT COMMENT 5 104-19-11 H/CTI-CLIENT COMMENT SUBMITTAL NO. DATE DATE DIC DESCRIPTION H/CT BP SUBMITTAL SITE NAME WA1 GARDINER - LTE ATC SITE #82962 APN: 801181001 SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE OVERALL SITE PLAN SHEET NO. A-1.0 ij 03 2 7 2011 J Ll JEFF!_RON COUNTY OF COP!'r' !I '"lY DrvT!,QPMlFNT GRAVELAREA F—NOTES: 1. SITE PLAN IS DERIVED FROM: EXISTING DRAWINGS, GIS, AERIAL IMAGES AND SITE PHOTOS. 2. PROPERTY BOUNDARIES AND TRUE NORTH ARE APPROXIMATE AND DERIVED FROM GIS. 3. CONTRACTOR SHALL VERIFY FINAL ANTENNA AZIMUTHS WITH CLIENT REPRESENTATIVE PRIOR TO COMMENCING INSTALLATION 4. PRIOR TO MATERIALS PROCUREMENT CONTRACTOR SHALL FIELD VERIFY CONDITION OF STRUCTURE AT NEW MOUNTING LOCATION TO ENSURE EXISTING CONDITIONS ARE SUITABLE AT SPECIFIED ELEVATION. Tl� EQUIPMENT SELTER _c f p x- v x x -X— T x x x x x x x (E) 121 ACCESS GATE (E) GRAVEL ACCESS ROAD 1 1 ENLARGED SITE PLAN m ;u m z G) m 0) \'/ V SCALE: 1/16"=1'-0"(11X17) 0' SCALE: 1/8"=l' -0"(22X34) 11 Cascadia\PM 8760122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 e -t. oAL�o o- tZ CPM PROJECT NO.: 3649 = I PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 \AH/CT 90% REVIEW 4 04-11-10 \AH/CT CLIENT COMMENT 5 04-19-11 H/CTI CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11 \AH/CT BP SUBMITTAL mmmmmommmmmma SITE NAME WA1 GARDINER - LTE ATC SITE #82962 APN: 801181001 SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE N ENLARGED SITE PLAN W E s SHEET NO. 321 I R E--, C �c - APR 2 7 2011 JEFFU "SON' Co[jiv,-y (E) VERIZON WIRELESS OMNI ANTENNA TIP HEIGHT 191'-0" AGL E TOP OF LATTICE TOWER 11 �- 177'-0" AGL (E) OTHER CARRIER'S ANTENNA ARRAY (E) OTHER CARRIER'S ANTENNA ARRAY AL (N V) ERIZON WIRELESS PANEL ANTENNA TIP HEIGHT (E) VERIZON WIRELESS OMNI 1841-011AGL ANTENNAS TO BE REPLACED (E) OTHER CARRIER'S (E) TOWER BEACON LIGHT I ANTENNA ARRAY (E) OTHER CARRIER'S ANTENNA ARRAY (E) OTHER CARRIER'S MICROWAVE ANTENNA (N) VERIZON WIRELESS 4' MW ANTENNA 117'-0" AG L (E) OTHER CARRIER'S MICROWAVE ANTENNA F; ` 714'-0"AMSC 17 EXISTING EAST ELE NATION SCALE: 1" = 20'-0" (11X17) 0' SCALE: 1" = 10'-0" (22X34) 10' 20' m E GRADE k 714'-0" AMSL 2 PROPOSED EAST ELEVATION (N) VERIZON WIRELESS PANEL ANTENNAS (REPLACING EXISTING OMNI ANTENNAS) (SEE SHEET A-4.0 FOR ANTENNA CONFIGURATION DETAILS) (E) TOWER BEACON LIGHT (E) OTHER CARRIER'S MICROWAVE ANTENNA (N) VERIZON WIRELESS 4' MICROWAVE ANTENNA @117' AGL CENTERLINE, AZIMUTH = 99.18° TO: WA -1 PORT LUDLOW (SEE SHEET A-4.1 FOR DETAILS) SCALE: 1" = 20'-0" (11X17) 0' SCALE: 1" = 10'-0" (22X34) 11 10' 20' all PM 8760122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 � �,P ; 1- 27 •1 Z -- R 2 1: (E) VERIZON WIRELESS TRI -SECTOR LOW -PROFILE ANTENNA PLATFORM (TO REMAIN) W W D ° 11®LEM wite/eSS (E) OMNI ANTENNA TO BE REMOVED & REPLACED (TYP OF 4) 0 P W D Cascadia PM - - 8760122ND AVE, NE KIRKLAND, WA 98033 ,y o PH: (425) 828-1008 CONTRACTOR TO REUSE (E) OMNI ANTENNA PIPE MAST & J MOUNTING HARDWARE IF PRESENT. OTHERWISE PROVIDED BY CONTRACTOR t. TO MATCH (E) SCALE: NTS (11X17) FRONT SIDE BACK 1 EXISTING ANTENNA PLAN4 SCALE. NTS (2 X36) n ANTENNA "B" ANTENNA "C" ANTENNA A . ANTENNA"A TE: ROTATE EXISTING (N) VERIZON WIRELESS NO TOP TOP PANEL ANTENNA PLATFORM AS ALLOWED BY TOP Al . -�<-o "ANTEL" LPA-80090-8CF TOWER MANUFACTURER'S DESIGN TO MATCH ANTENNA TYP OF 2 PER SECTOR ( SECTOR) MANUFACTURER: MANUFACTURER: ANTEL MANUFACTURER: ANTEL MANUFACTURER: ANTEL - y PART NUMBER: LPA-80090-8CF PART NUMBER: BXA-185090-8CF PART NUMBER: BXA-70080 8CF`�z-- ���j, 2 (N) DIPLEXERS (STACKED) � - 2 PER SECTOR (OR EQUIVALENT) (OR EQUIVALENT) (OR EQUIVALENT) (TYP OF 6 11 LENGTH: 94.6" LENGTH: 94.6 LENGTH. 48.2 ,f ° ANTENNA "B" ONLY) WIDTH: 8.0 WIDTH: 9.4WIDTH: 6.1�� — ANTENNA "B": DEPTH 5.711DEPTH 5.2 DEPTH 5.79" �? (N) VERIZON WIRELESS WEIGHT: 23.00 lbs WEIGHT: 11.00 lbs WEIGHT: 23.00 lbs _CPM PROJECT NO.: 3649 PANEL ANTENNA "ANTEL" BXA-185090-8CF BETA SECTOR VERIZON ANTENNA INFORMATION AZIMUTH = 90° 2 (N) TMAs (STACKED) (TYP OF 6 - 2 PER SECTOR - ANTENNA "C" ONLY) ANTENNA "C": (N) VERIZON WIRELESS o y PANEL ANTENNA Ohr "ANTEL" BXA-70080-8CF_2 NOTE: CONTRACTOR SHALL V� N� VERIFY FINAL ANTENNA ANTENNA" A . AZIMUTHS W CLIENT (N) VERIZON WIRELESS REPRESENTITIVE PRIOR TO PANEL ANTENNA COMMENCING INSTALLATION Q" "ANTEL" LPA-80090-8CF COM C� (TYP OF 2 PER SECTOR) SCALE: NTS (11 X17) 2 NEW ANTENNA PLAN SCALE: NTS24X36 ( ) (E) VERIZON WIRELESS N VALMONT PART NO. 140499 PANEL ANTENNA 2-3/8" O.D. PIPE OR EQUAL SECTOR QTY. TIP HEIGHT FT. AGL ANTENNA LENGTH AZIMUTH MECHANICAL DOWN TILT NO. OF COAX RUNS COAX SIZE ANTENNA ALPHA 2 ±184'-0" ±7'-11" 3300 20 2 NEW 15/811 A 1 ±184'-0" ±4'-0" 3300 20 DIPLEXED B 1 ±184'-0" ±7'-11" 330° 1° 2 NEW 15/8 C BETA 2 ±184'-0" ±7'-11" 900 20 2 NEW 15/811 A 1 ±184'-0" ±4'-0" 900 20 DIPLEXED B 1 ±184'-0" ±7'-11" 900 - 2 NEW 15/811 C GAMMA 2 ±184'-0" ±7'-11" 2100 20 2 NEW 15/811 A 1 ±184'-0" ±4'-0" 2100 20 DIPLEXED B 1 ±184'-0" ±7'-11" 2100 - 2 NEW 15/811 C PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 H/CT 90% REVIEW 4 04-11-10 H/CTJ CLIENT COMMENT 5 04-19-11 H/CTJ CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11MH/CT ±250' BP SUBMITTAL 1 5/8" BETA ±250' 4 NEW 15/811 GAMMA 1250' 4 NEW SITE NAME WAl GARDINER - LTE ATC SITE #82962 APN: 801181001 SITE ADDRESS � (2) (N) 700MHz TOWER MOUNTED (N) VALMONT PART NO. O ANYONE AMPLIFIER MOUNTED TO (E) — 1696 STATE HWY 104 ANTENNA MOUNTING PIPE 62508 PIPE MOUNTS OR EQUAL (STACKED) (AWC-TMA-DD-700-C) REF: 2/4.1 NOTE: Q REFERENCE OWNERS MANUAL FOR CONNECTION AND MOUNTING INFORMATION FOR AMPLIFIER (E) CROSS FRAME rinr 1111/111A1T COAX LENGTH SCHEDULE SECTOR LENGTH #COAX DIAMETER ALPHA ±250' 4 NEW 1 5/8" BETA ±250' 4 NEW 15/811 GAMMA 1250' 4 NEW 15/811 NOTE: I QUILCENE, WA 98376 I COAX ROUTING TO MATCH EXISTING COAX ROUTE SHEET TITLE ANTENNA DETAILS U �C� vr� �rv� rir� mvviv � SHEET NO. SCALE: NTS (11X17) SCALE: NTS (11X17)SCALE: NTS (11X17) A-4.0 3 CRASS PLATE DETAIL SCALE: NTS (24X36) 4 MOUNT DETAIL SCALE: NTS (24X36) 5 ANTENNA & COAX SCHEDULE' SCALE: NTS (24X36) APR 272011 JEFFERSON COUNTY DEPT. OF COMMIUNITY DEVELOPMENT BACK VIEW TOP VIEW STIFF ARM PER MANUFACTURER SPECIFICATIONS 1 6' MICROWAVE DETAIL MANUFACTURER: RFS (RADIO FREQUENCY SYSTEMS) PART NUMBER: SD4-107BB DIAMETER: 4811 DEPTH: 29.419 OFFSET: 14.411 WEIGHT: 77 lbs MOUNTING BRACKET FURNISHED WITH ANTENNA BY MANUFACTURER. UNIVERSAL TAPERED MOUNT SCALE: NTS (11 X1 7) SCALE: NTS (22X34) 2 SITE PRO ONE PART# ADP—U. EASILY ADJUSTS FOR TAPER UP TO 6" IN 3/4" INCREMENTS. UNIVEERSAL MOUNTING HARDWARE INCLUDED. UNIVERSAL MOUNTING ROUND LEGS FROM 1" TO 8" AND 600 ANGLE SCALE: NTS (11 X1 7) 4 MICROWAVE MOUNT I SCALE: NTS (22X34) 5 MW STIFF ARM SHOWN ON BOTH SIDES (TYP) 33MM 0 STIFF ARMS. ADDITIONAL BRACKETS (NOT SHOWN) MAY BE REQUIRED. CONNECTION P,' ER MANUFACTURER SPECS. RE 3/A,,A STIFF ARM DETAIL NOT USED The use of the high wind kit improves the windload performance. The survival windspeed increases to 250 knilh (156 mph). Product Type Reinforcement Hardware Kit Tete Increased Windload Diameter. ft (m) 4(1.2) Material The windkit includes only the red marked parts and fixing hardwareOnly applicable for dual polarized antennas below 10 GHz I gI&IRM-1 4' DIA MICROWAVE DISH SCALE: NTS (11 X1 7) 3 SCALE: NTS (22X34) I SCALE: NTS (11 X1 7) 6 SCALE: NTS (22X34) I T -Mount +250' M Sway ba+r (0 33 mm) Hot dip galvanised steel NOTE: 41-011 DISH, INSTALL (2) KITS PER -ANTENNA MICROWAVE STIFF ARM NOT USED SCALE: NTS (11 X17) SCALE: NTS (22X34) SCALE: NTS (11 X17) SCALE: NTS (22X34) Cascadia 3ML 8760122ND AVE,, NE KIRKLAND., WA 98033 PH: (425) 828-1008 ISP .0 / - Zn - / 2-- e) R 2 L 2011 CPM PROJECT NO.: 3649 INO. NO. PRELIMINARY D/C DATE 0 DESCRIPTION 0 01-17-11 VD/C H/CTI 90% REVIEW 104-11-10 M/CT M/CT CLIENT COMMENT I I 5 104-19-11 HICT nw� CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11 H/CT BP SUBMITTAL SITE NAME WA1 GARDINER - LTE ATC SITE #82962 E F� E APR 2 7 2011 JEFFERSON COUNTY DEPT OF CONIMMNITY DEVELOPMENT APN: 801181001 SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE MW ANTENNA DETAILS SHEET NO. A-4.1 'w.�' ra,a r s a g x3a✓s,,,s< t 'a st a € i e s � .. � �, a .»....:� R R � �... +�,.. . .. � x '� rr , x, y e 1 SUBMITTAL NO. PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 \AH/CT 90% REVIEW 4 04-11-10MH/CT CLIENT COMMENT 5 04-19-11 H/CT CLIENT COMMENT 1 SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11MH/CT BP SUBMITTAL CONTRACTOR GENERAL NOTES 1. CONTRACTOR WILL PROVIDE ALL LABOR, MATERIALS, TOOLS, EQUIPMENT, SAFETY EQUIPMENT, TRANSPORTATION, AND SERVICES NECESSARY TO COMPLETE ALL THE WORK OUTLINED IN ALL THE DRAWINGS, SPECIFICATIONS, SCOPE OF WORK, BILL OF MATERIALS, AND ANY OTHER DOCUMENT ISSUED BY CLIENT'S REPRESENTATIVE AND THE WIRELESS SERVICES COMPANY. 2. THE CONTRACTOR SHALL COMPLY WITH ALL LOCAL AND NATIONAL CODES, LAWS, ORDINANCES, REGULATIONS, SAFETY REGULATIONS, ALL OSHA REGULATIONS, ALL PUBLIC AND MUNICIPAL AUTHORITIES, AND ANY UTILITY COMPANY REGULATIONS AND DIRECTIVES. 3. ALL MATERIALS SUPPLIED BY THE CLIENT'S REPRESENTATIVE REPRESENTATIVE, AND THE CONTRACTOR, SHALL BE INSTALLED IN ACCORDANCE WITH ALL LOCAL AND NATIONAL CODES, LAWS, ORDINANCES, REGULATIONS AND PER MANUFACTURER'S RECOMMENDATIONS. 4. ANY CONTRACTOR SUBMITTING BIDS ON ANY OF THE WORK IS REQUIRED TO VISIT EACH SITE PRIOR TO THE BID SUBMITTAL AND FAMILIARIZE HIMSELF/HERSELF WITH THE EXISTING CONDITIONS AND UNDERSTAND THE SCOPE OF WORK INTENDED FOR THE PROJECT. THIS WILL BE PERFORMED AT THE CONTRACTOR'S EXPENSE. 5. THE DRAWINGS AND SPECIFICATIONS ARE A GENERAL DIRECTIVE FOR THE SCOPE OF WORK. EXACT DIMENSIONS AND LOCATIONS MAY CHANGE IN THE FIELD. THE CONTRACTOR IS TO VERIFY THE DIMENSIONS AND LOCATIONS AND REPORT ANY AND ALL DISCREPANCIES TO CLIENT'S REPRESENTATIVE PRIOR TO COMMENCING THE RELATED WORK. ANY MINOR ERRORS OR OMISSIONS IN THE DRAWINGS AND SPECIFICATIONS, DOES NOT EXCUSE THE CONTRACTOR FROM COMPLETING THE PROJECT AND IMPROVEMENTS IN ACCORDANCE WITH THE INTENT OF THESE DOCUMENTS. 6. ALL SITES SHALL BE KEPT CLEAN AND FREE OF DEBRIS ON A DAILY BASIS. ALL TRASH AND MATERIALS NO LONGER BEING USED AT THE SITE MUST BE REMOVED AND PROPERLY DISPOSED OF ON A DAILY BASIS. ANY EXCESS MATERIAL WILL BE RETURNED TO CLIENT'S REPRESENTATIVE AND DELIVERED TO THE WAREHOUSING FACILITY PER THE DIRECTION OF CLIENT'S REPRESENTATIVE.. 7. THE CONTRACTOR SHALL NOT PROCEED WITH ANY WORK AT THE SITE PRIOR TO A NOTICE TO PROCEED (NTP) HAS BEEN ISSUED AND A PRE -CONSTRUCTION MEETING AT THE SITE HAS TAKEN PLACE. 8. ALL WORK AND MATERIALS FURNISHED BY THE CONTRACTOR SHALL HAVE A WRITTEN 18 MONTH WARRANTY STARTING AT THE ACCEPTANCE OF THE SITE FROM CLIENT'S REPRESENTATIVE. 9. THE CONTRACTOR SHALL HAVE DESIGNATED A MANAGER ON SITE AT ALL TIMES THAT ANY WORK IS BEING PERFORMED. A SUB -CONTRACTOR IS NOT DEFINED AS A DESIGNATED MANAGER. 10. THE CONTRACTOR SHALL PROVIDE A SCHEDULED LIST OF ALL SUB -CONTRACTORS, WHICH SHALL INCLUDE ADDRESSES, CELL PHONE NUMBERS, HOME PHONE NUMBERS, VERIFICATION OF INSURANCE, ANY AND ALL PERTINENT LICENSES, AND AN ACCURATE SCHEDULE FOR THE PROJECT PRIOR TO THE ISSUANCE OF AN NTP. 11. THE CONTRACTOR IS TO KEEP A COMPLETE AND UP-TO-DATE SET OF THE DRAWINGS, SPECIFICATIONS, SCOPE OF WORK, AND BILL OF MATERIAL ON THE SITE AT ALL TIMES. THIS WILL BE REFERENCED AS THE AS -BUILT DRAWINGS AND MUST BE KEPT CURRENT ON A DAILY BASIS. THIS IS IN ADDITION TO THE PERMIT SET. 12. A NEW AND CLEAN SET OF CONTRACT DOCUMENTS WILL BE ISSUED TO THE CONTRACTOR NEAR THE COMPLETION OF THE PROJECT TO BE USED TO TRANSFER THE INFORMATION FROM THE FIELD COPY OF AS -BUILT DRAWINGS TO THE NEW COPY. THIS NEEDS TO BE SUBMITTED TO CLIENT'S REPRESENTATIVE WITH THE CLOSEOUT DOCUMENTS. 13. ON ANY CO -LOCATION SITE, THE CONTRACTOR AND ANY AND ALL ASSIGNS ARE NOT TO USE EXISTING POWER OR TAMPER WITH ANY EQUIPMENT BELONGING TO ANY OTHER CARRIER. FAILURE TO ADHERE TO THIS WILL CAUSE IMMEDIATE DISMISSAL OF THE CONTRACTOR FROM THE PROJECT. 14. THE CONTRACTOR IS RESPONSIBLE FOR SCHEDULING ALL INSPECTIONS AND TESTING REQUIRED FOR EACH PROJECT. A 48-HOUR NOTIFICATION TO CLIENT'S REPRESENTATIVE IS REQUIRED FOR ALL INSPECTIONS AND TESTING. A FIELD COPY OF ALL INSPECTION AND TESTING REPORTS AS WELL AS TRUCK TICKETS MUST BE SUBMITTED TO CLIENT'S REPRESENTATIVE WITHIN 24 HOURS OF THE INSPECTION OR TEST. 15. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL MATERIAL ISSUED TO HIM/HER, AND TO REPORT ANY SHORTAGES AND DISCREPANCIES TO CLIENT'S REPRESENTATIVE AT THE TIME OF ISSUANCE. THE CONTRACTOR SHALL STORE THESE MATERIALS PROPERLY, ACCORDING TO THE MANUFACTURER'S RECOMMENDATIONS AND IN A MANNER THAT WILL NOT VOID THE WARRANTY ON ANY ITEM. IF ANY ITEM IS DAMAGED OR UNUSABLE DUE TO IMPROPER HANDLING AND STORAGE, THE CONTRACTOR WILL REPLACE IT AT HIS/HER EXPENSE. 16. THE CONTRACTOR IS RESPONSIBLE TO FURNISH PROPER FACILITIES FOR THE WORKERS ON EACH PROJECT FOR THE DURATION OF THAT PROJECT. 17. THE CONTRACTOR IS RESPONSIBLE TO MAINTAIN THE PRESENT CONDITION OF ANY EXISTING BUILDINGS, LANDSCAPING, FENCING, EQUIPMENT, WALKS, DRIVES, AND ATTACHMENTS. IF ANY DAMAGE SHOULD OCCUR, THE CONTRACTOR IS RESPONSIBLE TO RESTORE THE DAMAGE TO A BETTER OR NEW CONDITION. PART 1 - PROJECT GENERAL NOTES 1.1 SCOPE OF WORK A. PROVIDE ALL LABOR, MATERIAL, TOOLS, EQUIPMENT, TRANSPORTATION AND SERVICES NECESSARY FOR AND INCIDENTAL TO COMPLETION OF ALL WORK AS INDICATED ON THE DRAWINGS AND / OR AS SPECIFIED HEREIN. 1.2 DRAWING USE AND INTERPRETATION A. THE DRAWINGS ARE DIAGRAMMATIC AND INDICATE THE GENERAL ARRANGEMENT OF SYSTEMS AND EQUIPMENT UNLESS INDICATED OTHERWISE BY DIMENSIONS OR DETAILS. EXACT EQUIPMENT LOCATIONS AND ROUTINGS, ETC. SHALL BE GOVERNED BY ACTUAL FIELD CONDITIONS AND/OR INSTRUCTIONS OF THE ENGINEER AND/OR CLIENT'S REPRESENTATIVE. 1.3 COMPLETE SYSTEMS A. GENERAL: FURNISH AND INSTALL ALL MATERIALS AS REQUIRED FOR COMPLETE SYSTEMS, WHETHER SPECIFICALLY INDICATED OR NOT. ALL SYSTEMS SHALL BE COMPLETELY ASSEMBLED, TESTED, ADJUSTED, DEMONSTRATED TO BE READY FOR OPERATION PRIOR TO CLIENT'S REPRESENTATIVE'S ACCEPTANCE. 1.4 CODES AND REGULATIONS A. GENERAL: COMPLY WITH ALL GOVERNING FEDERAL, STATE AND LOCAL LAWS, ORDINANCES, CODES, RULES AND REGULATIONS. WHERE THE CONTRACT DOCUMENTS EXCEED THESE REQUIREMENTS, THE CONTRACT DOCUMENTS SHALL GOVERN. IN NO CASE SHALL WORK BE INSTALLED CONTRARY TO OR BELOW MINIMUM LEGAL STANDARDS. B. UTILITIES: COMPLY WITH ALL APPLICABLE RULES, RESTRICTIONS, AND REQUIREMENTS OF THE UTILITY COMPANIES SERVING THE PROJECT SITE / FACILITIES. C. NON-COMPLIANCE: SHOULD ANY WORK BE PERFORMED WHICH IS FOUND NOT TO COMPLY WITH ANY OF THE ABOVE, CONTRACTOR SHALL PROVIDE ALL WORK AND PAY ALL COSTS NECESSARY TO CORRECT THE DEFICIENCIES. 1.5 REFERENCE STANDARDS A. ALL LATEST PUBLISHED STANDARDS OF THE FOLLOWING ASSOCIATIONS / ORGANIZATIONS SHALL BE FOLLOWED AND APPLIED WHERE APPLICABLE, AS MINIMUM REQUIREMENTS. 1) (ANSI) AMERICAN NATIONAL STANDARDS INSTITUTE. 2) (ASTM) AMERICAN SOCIETY FOR TESTING AND MATERIALS. 3) (ETL) ELECTRICAL TESTING LABORATORY. 4) (ICEA) INSULATED CABLE ENGINEERS ASSOCIATION. 5) (IEEE) INSTITUTE OF ELECTRICAL AND ELECTRONIC ENGINEERS. 6) (NBFU) NATIONAL BOARD OF FIRE UNDERWRITERS. 7) (NEMA) NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION. 8) (NESC) NATIONAL ELECTRIC SAFETY CODE. 9) (NFPA) NATIONAL FIRE PROTECTION ASSOCIATION. 10) (UL) UNDERWRITER'S LABORATORIES. 11) (BOCA) BUILDING OFFICIALS & CODE ADMINISTRATORS. 12) (NEC) NATIONAL ELECTRICAL CODE. 1.6 PERMITS A. GENERAL: ALL PERMITS REQUIRED BY ALL APPLICABLE AGENCIES, WILL BE OBTAINED BY SUBCONTRACTOR. 1.7 MAINTAINING SITE CONDITIONS THE CONTRACTOR IS RESPONSIBLE FOR MAINTAINING A NEAT AND ORDERLY PROJECT SITE. REMOVE AND DISPOSE OFF SITE ALL RUBBISH, WASTE, LITTER, AND ALL FOREIGN SUBSTANCES IN A LEGAL MANNER. REMOVE PETRO -CHEMICAL SPILLS, STAINS, AND OTHER FOREIGN DEPOSITS IN COMPLIANCE WITH OSHA REGULATIONS. RETURN ALL SURFACES TO ORIGINAL CONDITION. 1.9 METALS 1. ALL LABOR, MATERIALS, FABRICATION AND WORKMANSHIP SHALL CONFORM TO THE CODES AND STANDARDS OF ASTM AND AWS. 2. ALL WORK SHALL BE DONE BY A CERTIFIED WELDER. THE CONTRACTOR SHALL SUBMIT A COPY OF THE CERTIFICATION TO CLIENT'S REPRESENTATIVE. 3. ALL STEEL USED SHALL BE HOT DIPPED GALVANIZED. 1.10 ANTENNAS AND CABLES 1. THE CONTRACTOR IS RESPONSIBLE FOR THE PROPER STORAGE AND HANDLING OF ALL MATERIALS ONCE THEY HAVE BEEN RELEASED FROM THE WAREHOUSE. 2. INSTALLATION OF ALL MATERIALS SHALL BE DONE IN STRICT ADHERENCE TO MANUFACTURER'S RECOMMENDATIONS. 3. TOWER TECHNICIANS MUST BE CURRENT ANDREWS CERTIFIED FOR CABLE CONNECTOR INSTALLATIONS. 4. THE CONTRACTOR SHALL RUN ALL LINES AND CONDUITS IN A NEAT, ORDERLY AND STRAIGHT FASHION PROVIDING ANCHORING AS RECOMMENDED BY THE MANUFACTURER AND WHEREVER NECESSARY TO SUPPORT THE LINES PROPERLY. 1.11 WARRANTIES 1. THE CONTRACTOR SHALL WARRANTY ALL GENERAL WORK FOR A MINIMUM OF 18 MONTHS OR AS STATED ELSEWHERE IN THE CONTRACT. 2. ROOF WARRANTY: ALL WORK ON ROOFS SHALL BE PERFORMED IN FULL COMPLIANCE WITH THE ROOF MANUFACTURER AND CONTRACTOR SHALL OBTAIN WRITTEN VERIFICATION FROM ROOF MANUFACTURER THAT THE WARRANTY REMAINS VALID AFTER CONSTRUCTION. GROUNDING 1. THE CONTRACTOR SHALL VERIFY WITH CLIENT'S REPRESENTATIVE THAT ALL CONDUIT SYSTEMS, EQUIPMENT, DEVICES, PANELS, LINES, TRAYS, BRIDGES, PLATFORMS, AND ANY/ALL ITEMS ARE GROUNDED PROPERLY. 2. THE GROUNDING SYSTEM CONNECTIONS SHALL BE MADE WITH EXOTHERMIC WELDS AND/OR MECHANICAL TWO -LUG COMPRESSION CONNECTORS AS INDICATED ON PLANS. USE ONLY STAINLESS STEEL SCREWS, BOLTS WASHERS, AND NUTS FOR FASTENING. 3. CLEAN SURFACES THOROUGHLY BEFORE APPLYING GROUND LUGS OR CLAMPS. IF SURFACE IS COATED, THE COATING MUST BE REMOVED DOWN TO THE BARE METAL. AFTER THE COATING HAS BEEN REMOVED, APPLY A NON -CORROSIVE APPROVED COMPOUND TO THE CLEANED SURFACE AND INSTALL LUGS OR CLAMPS. WHERE GALVANIZING IS REMOVED FROM METAL, IT SHALL BE PAINTED OR TOUCHED UP WITH COLD GALVANIZING PAINT SUCH AS GLAVMOX OR EQUAL. 4. ALL CLAMPS, SLEEVES, AND SUPPORTS USED TO SUPPORT OR CHANNEL THE GROUNDING SYSTEM CONDUCTORS AND PVC CONDUITS SHALL BE PVC TYPE NON-CONDUCTIVE. DO NOT USE METAL BRACKETS OR SUPPORTS THAT WOULD FORM A COMPLETE RING AROUND ANY GROUNDING CONDUCTOR. 5. ALL GROUNDING CONNECTIONS SHALL BE COATED WITH T&B KOPR SHIELD ANTI -CORROSIVE AGENT. NO SUBSTITUTIONS ARE PERMITTED. VERIFY THE PRODUCT WITH CLIENT'S REPRESENTATIVE PRIOR TO USAGE. 6. GROUND THE ANTENNA BASES, FRAMES, CABLE TRAYS AND RACKS, AND ANY OTHER METALLIC COMPONENTS WITH #2 GROUNDING CONDUCTORS, AND CONNECT TO THE SURFACE -MOUNTED GROUND BARS. CONNECTION DETAILS SHALL BE PERFORMED PER THE MANUFACTURER'S SPECIFICATIONS AND RECOMMENDATIONS. 7. THE ANTENNA CABLES SHALL BE GROUNDED AT THE TOP AND BOTTOM OF THE VERTICAL RUN FOR LIGHTNING PROTECTION. THE ANTENNA CABLE SHIELD SHALL BE BONDED TO A COPPER GROUND BUS AT THE LOWERMOST POINT OF A VERTICAL RUN JUST BEFORE IT BEGINS TO BEND TOWARD THE HORIZONTAL PLANE. WIRE RUNS TO GROUND SHALL BE KEPT AS STRAIGHT AND SHORT AS POSSIBLE. THE ANTENNA CABLE SHIELD SHALL BE GROUNDED JUST BEFORE ENTERING THE CELL CABINET. ANY ANTENNA CABLES OVER 200 FEET IN VERTICAL LENGTH SHALL ALSO BE EQUIPPED WITH ADDITIONAL GROUNDING AT MID -POINT. 8. THE CONTRACTOR, UPON COMPLETION OF THE GROUNDING SYSTEM, SHALL SCHEDULE A TEST OF THE SYSTEM. CLIENT'S REPRESENTATIVE' REPRESENTATIVE WILL BE INFORMED 48 HOURS IN ADVANCE OF THE TEST. 'M ° -` 'mr-' ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 CPM PROJECT NO.: 3649 SUBMITTAL NO. PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 H/CT 90% REVIEW 4 04-11-10 H/CT CLIENT COMMENT 5 04-19-11 H/CT CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11MH/CT BP SUBMITTAL SITE NAME WAl GARDINER - Q ATC SITE #82962 l� JEFFERSON COUNTY DENT. OF COA�MUNITY DEUFI.OPMENT ____ APN: 801181001 SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE GENERAL NOTES SHEET NO. GN-1 PART 2 - PRODUCTS 2.1 GENERAL A. GENERAL REQUIREMENTS: ALL MATERIALS AND EQUIPMENT SHALL BE IN ACCORDANCE WITH CONTRACT DOCUMENTS AND STANDARD PRODUCTS OF THE VARIOUS MANUFACTURERS, WITH ALL MATERIALS AND EQUIPMENT TO BE NEW, CLEAN, UNDAMAGED, AND FREE OF DEFECTS AND CORROSION. B. ACCEPTABLE PRODUCTS: THE PRODUCT OF A SPECIFIED OR APPROVED MANUFACTURER WILL BE ACCEPTABLE ONLY WHEN THE PRODUCT COMPLIES WITH OR IS MODIFIED AS NECESSARY TO COMPLY WITH ALL REQUIREMENTS OF THE CONTRACT DOCUMENTS. C. COMMON ITEMS: WHERE MORE THAN ONE OF ANY SPECIFIC ITEM IS REQUIRED, ALL SHALL BE OF THE SAME TYPE AND MANUFACTURER. D. UL LISTING: ALL MATERIALS AND EQUIPMENT SHALL BE UNDERWRITERS LABORATORIES (UL) LISTED AND LABELED, WHERE UL STANDARDS AND LISTINGS EXIST FOR SUCH MATERIALS OR EQUIPMENT. 2.2 RACEWAY SYSTEMS A. RACEWAY SIZING: AS REQUIRED BY NEC (MINIMUM) WITH OVERSIZED RACEWAYS AS INDICATED ON DRAWINGS. MINIMUM CONDUIT SIZE: 3/4 - INCH, UNLESS INDICATED OTHERWISE. B. RACEWAY TYPES: RIGID GALVANIZED STEEL CONDUIT, ELECTRICAL METALLIC TUBING (EMT), FLEXIBLE STEEL CONDUIT, LIQUID -TIGHT FLEXIBLE STEEL CONDUIT, SCHEDULE 40 HEAVY WALL, AND SCHEDULE 80 EXTRA- HEAVY WALL RIGID NON-METALLIC (PVC) CONDUIT, CONFORMING TO APPLICABLE ANSI, NEMA AND UL STANDARDS. C. FITTINGS: ALL RACEWAY FITTINGS (EXCEPT FOR RIGID NON-METALLIC CONDUIT) TO BE STEEL OR MALLEABLE IRON, AND UL -LISTED FOR THE INTENDED APPLICATION. EMT FITTING TO BE COMPRESSION TYPE. D. OUTLET BOXES (SURFACE MOUNTED): CADMIUM PLATED CAST OR MALLEABLE IRON. E. PULL AND JUNCTION BOXES AND WIREWAYS: USE AS INDICATED AND REQUIRED. JUNCTION BOXES FOR GENERAL INDOOR USE (DRY LOCATIONS) TO BE OF GALVANIZED CODE GAUGE STEEL CONSTRUCTION MINIMUM 4" SQUARE x 1 1/2" DEEP WITH SCREW -ON COVERS. WIREWAYS TO BE UL LISTED, SHEET STEEL CONSTRUCTION WITH SCREW -ON COVERS. FOR EXTERIOR AND DAMP OR WET INDOOR LOCATIONS, USE BOXES AND WIREWAYS APPROVED FOR SUCH USE. F. PIPE SLEEVES: RIGID STEEL CONDUIT OR IRON PIPE. G. CONDUIT SEALS FOR CAST -IN-PLACE CONCRETE APPLICATIONS - ACCEPTABLE MANUFACTURERS: O-Z/GEDNEY TYPE "FSK"; THUNDERLINE CORPORATION "LINK SEAL" WITH "LINK SEAL WALL SLEEVE. FOR CORE -DRILLED AND PRE -CAST OPENING APPLICATIONS - ACCEPTABLE MANUFACTURERS: O -Z / GEDNEY TYPE "CSML;" THUNDERLINE CORP. "LINK SEAL." H. SWEEPS: ALL SWEEPS FOR COMMUNICATION EQUIPMENT OR INTO CONCRETE PAD SHALL BE MIN. 24" RADIUS. 2.3 ELECTRICAL IDENTIFICATION A. NAMEPLATES: THREE -LAYER LAMINATED PLASTIC WITH MINIMUM 3/16" HIGH WHITE ENGRAVED CHARACTERS ON BLACK BACKGROUND AND PUNCHED FOR MECHANICAL FASTENING. B. FASTENERS: SELF -TAPPING STAINLESS-STEEL SCREWS NUMBER 10-32 STAINLESS STEEL MACHINE SCREWS WITH NUTS AND FLAT LOCK WASHERS. C. UNDERGROUND WARNING TAPE: SIX-INCH WIDE POLYETHYLENE TAPE, PERMANENTLY BRIGHT COLORED WITH CONTINUOUS -PRINTED LEGEND INDICATING GENERAL TYPE OF UNDERGROUND LINE BELOW AND "CAUTION". COLORS AS FOLLOWS: 1) RED = ELECTRIC, 2) ORANGE = COMMUNICATIONS. D. MARKING PENS: PERMANENT, WATERPROOF, QUICK DRYING BLACK INK. ACCEPTABLE MANUFACTURERS: SANFORD FINE POINT "SHARPIE," OR EQUAL. E. WIRE TAGS: VINYL OR VINYL -CLOTH SELF-ADHESIVE WRAPAROUND TYPE INDICATING APPROPRIATE CIRCUIT NUMBER, ETC. 2.4 GROUNDING A. SYSTEM DESCRIPTION: GROUNDING NETWORK SYSTEM SHALL ESTABLISH AN EARTH -RESISTANCE TO THE REFERENCE GROUND POINT NOT TO EXCEED 5 OHMS FOR BUILDING, CONSISTING OF BONDING OF STRUCTURE AND OTHER METAL OBJECTS INCLUDING GROUNDING ELECTRODES AND INTERCONNECTING CONDUCTORS. THIS SHALL BE PERFORMED WITH THE 3 POINT TEST METHOD. B. MATERIAL - INDICATED AS FOLLOWING: 1. WATER SERVICE METALLIC PIPE 2. BUILDING STEEL 3. CONDUCTORS: COPPER STRANDED OR SOLID TINNED BARE SIZE AS INDICATED 4. GROUND RODS: 5/8" DIA. X 10'-0" LONG COPPER CLAD GROUND ROD 5. CHEMICAL GROUND RODS: XIT GROUND ROD 10'-0" STRAIGHT SHAFT TYPE 6. COMPRESSION: HYGROUND AS MANUFACTURED BY FCI BURNDY. CONNECTIONS SHALL BE PROTECTED FROM CORROSION AS MANUFACTURED BY ZRC CHEMICAL PRODUCTS CO., AS NEEDED. 7. CONNECTIONS: DOUBLE HOLE LUGS FOR ALL MECHANICAL CONNECTIONS. 8. EXOTHERMIC: CADWELD WITH PROPER MOLDS B. RECEPTACLES: 20 AMP, 125V, NEMA 5-208V DUPLEX TYPE. FOR INDOOR MOUNTED, USE STAINLESS STEEL COVER. FOR OUTDOOR OR WET LOCATION MOUNTED, USE DEVICE RATED FOR USE. PROVIDE GFCI TYPE WITH SOLID STATE GROUND FAULT SENSING & 5 MA TRIP FOR OUTDOOR OR WET LOCATIONS. 2.5 CABLE TRAY A. PROVIDE A COMPLETE CABLE TRAY SYSTEM WITH BENDS, FITTINGS, ACCESSORIES, ETC. AS REQUIRED. B. DESCRIPTION: ALUMINUM ALLOY CONSTRUCTION. TYPE: LADDER WITH 12" MAXIMUM SPACING. DEPTH: MINIMUM 4". WIDTH: AS INDICATED ON DRAWINGS, (MINIMUM 12" HORIZONTAL RUNS, MINIMUM 6" VERTICAL RUNS). SUPPORT SPAN: 8 FOOT MINIMUM, UNLESS OTHERWISE NOTED. LOADING: 100 POUNDS/FOOT. RADIUS: 36" MINIMUM, (SMALLER RADIUS MAY BE PERMITTED IF APPROVED BY CLIENT'S REPRESENTATIVE). COVER: VENTILATED .063 ALUMINUM, PROVIDE WHERE INDICATED. C. GROUNDING: BOND ALL TRAY SECTIONS USING #2 AWG BARE COPPER GROUND. D. ACCEPTABLE MANUFACTURERS: NEWTON INSTRUMENTS OR EQUIVALENT 2.14 SURGE SUPPRESSION A. PRODUCTS MANUFACTURED AS SPECIFIED BY CLIENT DOCUMENTATION. B. FURNISHED BY CONTRACTOR AND INSTALLED BY CONTRACTOR. PART 3 - EXECUTION 3.1 GENERAL A. THE INSTALLATION OF ALL WORK SHALL BE IN ACCORDANCE WITH THE INTENT OF THE CONTRACT DOCUMENTS. B. INSTALLATION REQUIREMENTS: ALL MATERIALS AND EQUIPMENT SHALL BE INSTALLED AS RECOMMENDED BY THE RESPECTIVE MANUFACTURERS, BY MECHANICS EXPERIENCED AND SKILLED IN THEIR TRADE, IN A NEAT AND WORKMANLIKE MANNER IN ACCORDANCE WITH THE STANDARDS OF THE TRADE, AND SO AS NOT TO VOID ANY WARRANTY OF UL LISTING. C. ADMINISTRATION AND SUPERVISION: ALL WORK SHALL BE PERFORMED UNDER THE CONTRACTOR'S DIRECT SUPERVISION, USING SUFFICIENT AND QUALIFIED PERSONNEL AS NECESSARY TO COMPLETE THE WORK IN ACCORDANCE WITH THE PROGRESS SCHEDULE. THE CONTRACTOR SHALL ASSIGN ONE OR MORE COMPETENT SUPERVISORS WHO SHALL HAVE AUTHORITY TO ACCEPT AND EXECUTE ORDERS AND INSTRUCTIONS, AND WHO SHALL COOPERATE WITH THE OTHER CONTRACTORS AND SUBCONTRACTORS, THE ENGINEER, AND CLIENT'S REPRESENTATIVE IN ALL MATTERS TO RESOLVE CONFLICTS AND AVOID DELAYS. D. MINIMUM MOUNTING HEIGHT: INSTALL EXPOSED RACEWAY AND ALL OTHER EQUIPMENT (EG. LIGHTING FIXTURES) WITH NOT LESS THAN 7'-6" CLEAR TO FINISHED FLOOR, UNLESS INDICATED OR APPROVED OTHERWISE, AND EXCLUDING RACEWAY AND EQUIPMENT MOUNTED ON WALLS. E. DIMENSIONS AND CLEARANCES: FIELD MEASURE ALL DIMENSIONS AND CLEARANCES AFFECTING THE INSTALLATION OF ELECTRICAL WORK, IN RELATION TO ESTABLISHED DATUM, BUILDING OPENINGS AND CLEARANCES, AND WORK OF OTHER TRADES, AS CONSTRUCTION PROGRESSES. 3.2 EXAMINATION A. CONDITIONS VERIFICATION: EXAMINE THE AREAS AND CONDITIONS UNDER WHICH THE WORK IS TO BE PERFORMED, AND IDENTIFY ANY CONDITIONS DETRIMENTAL TO THE PROPER AND TIMELY COMPLETION OF THE WORK. DO NOT PROCEED UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. 3.3 MOUNTING HEIGHTS A. GENERAL: INDICATED HEIGHTS ARE MEASURED FROM THE CENTER OF THE DEVICE OUTLET BOX TO THE FINISHED FLOOR OR GRADE, UNLESS INDICATED OTHERWISE. REQUEST INSTRUCTIONS FOR MOUNTING HEIGHTS NOT INDICATED. B. DEVICES: SWITCHES - 48" A.F.F. I RECEPTACLES - 18" A.F.F. I THERMOSTAT - 48" A.F.F. 3.4 HOLES, SLEEVES, AND OPENINGS A. GENERAL: PROVIDE ALL HOLES, SLEEVES, AND OPENINGS REQUIRED FOR THE COMPLETION OF WORK, AND RESTORE ALL DAMAGED SURFACES TO MATCH SURROUNDING SURFACES. MAINTAIN INTEGRITY OF ALL FIRE AND SMOKE RATED BARRIERS USING APPROVED FIRESTOPPING SYSTEMS. WHEN CUTTING HOLES OR OPENINGS, OR INSTALLING SLEEVES, DO NOT CUT, DAMAGE OR DISTURB STRUCTURAL ELEMENTS OR REINFORCING STEEL, UNLESS APPROVED IN WRITING BY THE PROJECT STRUCTURAL ENGINEER. B. CONDUIT PENETRATIONS: SIZE CORE DRILLED HOLES SO THAT AN ANNULAR SPACE OF NOT LESS THAN 1/4" AND NOT MORE THAN 1" IS LEFT AROUND THE CONDUIT. WHEN OPENINGS ARE CUT IN LIEU OF CORE DRILLED, PROVIDE SLEEVE IN ROUGH OPENING. SIZE SLEEVES TO PROVIDE AN ANNULAR SPACE OF NOT LESS THAN 1/4" AND NOT MORE THAN 1" AROUND THE CONDUIT, PIPE, ETC. PATCH AROUND SLEEVE TO MATCH SURROUNDING SURFACES. 3.5 HANGERS AND SUPPORTS A. GENERAL: RIGIDLY SUPPORT AND SECURE ALL MATERIALS, RACEWAY AND EQUIPMENT TO BUILDING STRUCTURE USING HANGERS, SUPPORTS AND FASTENER SUITABLE FOR THE USE, MATERIALS AND LOADS ENCOUNTERED. PROVIDE ALL NECESSARY HARDWARE. PROVIDE CONDUIT SUPPORTS AT MAXIMUM 5 FEET ON CENTER. B. OVERHEAD MOUNTING: ATTACH OVERHEAD MOUNTED EQUIPMENT TO STRUCTURAL FRAMEWORK OR SUPPORTING METAL FRAMEWORK. DO NOT MAKE ATTACHMENTS TO STEEL ROOFING, STEEL FLOORING OR CEILING MINERAL TILE. C. WALL MOUNTING: SUPPORT WALL MOUNTED EQUIPMENT BY MASONRY, CONCRETE BLOCK, METAL FRAMING OR SUB -FRAMING. D. EXTERIOR WALLS: MOUNT ALL EQUIPMENT LOCATED ON THE INTERIOR OR EXTERIOR BUILDING WALLS, AT LEAST ONE INCH AWAY FROM WALL SURFACE, USING SUITABLE SPACERS. E. STRUCTURAL MEMBERS: DO NOT CUT, DRILL OR WELD ANY STRUCTURAL MEMBER EXCEPT AS SPECIFICALLY APPROVED BY THE ENGINEER. F. INDEPENDENT SUPPORT: DO NOT SUPPORT MATERIALS OR EQUIPMENT FROM OTHER EQUIPMENT, PIPING, DUCTWORK OR SUPPORTS FOR SAME. G. TEMPORARY CONDITIONS: DO NOT ATTACH TO OR SUPPORT ELECTRICAL WORK FROM REMOVABLE OR KNOCKOUT PANELS OR TEMPORARY WALLS OR PARTITIONS. H. RACEWAY SUPPORTS: RIGIDLY SUPPORT ALL RACEWAY WITH MAXIMUM SPACINGS PER NEC, AND SO AS TO PREVENT DISTORTION OF ALIGNMENT DURING PULLING OPERATION. USE APPROVED HANGERS, CLAMPS AND STRAPS FOR INDIVIDUAL RUNS. DO NOT USE PERFORATED STRAPS OR TIE WIRES. WHERE MULTIPLE PARALLEL RACEWAYS ARE RUN TOGETHER, USE TRAPEZE TYPE HANGER ARRANGEMENT MADE FROM U -CHANNEL AND ACCESSORIES, SUSPENDED BY THREADED RODS, AND ALLOW AT LEAST 25% SPARE CAPACITY FOR FUTURE INSTALLATION OF ADDITIONAL RACEWAYS. RIGIDLY ANCHOR VERTICAL CONDUITS SERVING FLOOR -MOUNTED OR "ISLAND" TYPE EQUIPMENT MOUNTED AWAY FROM WALLS WITH METAL BRACKET OR RIGID STEEL CONDUIT EXTENSION SECURED TO FLOOR. 1. MISCELLANEOUS SUPPORTS: PROVIDE ANY ADDITIONAL STRUCTURAL SUPPORT STEEL BRACKETS, ANGLES, FASTENERS AND HARDWARE AS REQUIRED TO ADEQUATELY SUPPORT ALL ELECTRICAL MATERIALS AND EQUIPMENT. J. ONE HOLE STRAPS SHALL NOT BE USED FOR CONDUITS LARGER THAN 3/4 INCH. 'M °@-�-mrx"�D AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 Exp A R2c2011 CPM PROJECT NO.: 3649 PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 H/CT 90% REVIEW 4 04-11-10 H/CT CLIENT COMMENT 5 04-19-11PH/CT CLIENT COMMENT SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11IAH/CT BP SUBMITTAL SITE NAME ATC SITE #82962 �PF� 2 7 2011 t 1 APN: 801181001 SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE GENERAL NOTES SHEET NO. GN-2 3.6 IDENTIFICATION A. GENERAL: LOCATE NAMEPLATE MARKING, OR OTHER IDENTIFICATION MEANS ON OUTSIDE OF EQUIPMENT OR BOX FRONT COVERS WHEN ABOVE CEILINGS AND WHEN IN MECHANICAL OR ELECTRICAL EQUIPMENT ROOMS OR OTHER UNFINISHED AREAS, AND ON INSIDE OF FRONT COVER WHEN IN FINISHED ROOMS /AREAS. USE CONTRACT DOCUMENT DESIGNATIONS FOR IDENTIFICATION UNLESS INDICATED OTHERWISE. B. NAMEPLATES: PROVIDE NAMEPLATE ENGRAVED WITH EQUIPMENT DESIGNATION FOR EACH SAFETY SWITCH, PANELBOARD, TRANSFORMER, MOTOR STARTER, AND ALL OTHER EQUIPMENT, ETC. C. UNDERGROUND WARNING TAPE: DURING TRENCH BACKFILLING FOR EACH UNDERGROUND ELECTRICAL, TELEPHONE, SIGNAL AND COMMUNICATIONS LINE, PROVIDE A CONTINUOUS UNDERGROUND WARNING TAPE LOCATED DIRECTLY ABOVE LINE, AT SIX TO EIGHT INCHES BELOW FINISHED GRADE. D. MARKING PEN LABELING: MARK EACH JUNCTION AND PULL BOX INDICATING SOURCE DESIGNATION AND CIRCUIT NUMBER(S) FOR THE ENCLOSED CONDUCTORS. E. LABEL ALL WIRES AND CABLES AT EVERY POINT OF TERMINATION AND IN ALL PULL BOXES AND JUNCTION BOXES. FOR POWER CIRCUITS, APPLY WIRE TAGS INDICATING APPROPRIATE CIRCUIT OR FEEDER NUMBER TO EACH CONDUCTOR PRESENT IN DISTRIBUTION PANEL AND PANELBOARD GUTTERS, AND TO EACH CONDUCTOR IN PULL AND JUNCTION BOXES. END LESS THAN 900 IN ANY LOCATION WITH A MINIMUM BEND RADIUS OF 8". 3.7 GROUNDING SYSTEM 1) ALL GROUND CONNECTIONS TO THE GROUND BAR SHALL BE MADE WITH DOUBLE HOLE HYDRAULICALLY INDENTED LUGS, EXCEPT FOR TWO CADWELDS, AS SHOWN ON PLANS. 2) WHERE GROUND CONNECTIONS ARE MADE, THE CONTACT POINTS ARE TO BE CLEANED AND MADE FREE OF FOREIGN MATERIALS, SUCH AS PAINT AND CORROSION, TO ENSURE AN ADEQUATE BOND. 3) ALL GROUNDING AND BONDING INSTALLATIONS AND CONNECTIONS SHALL COMPLY WITH VERIZON WIRELESS WIRELESS SERVICES ELECTRICAL AND GROUNDING SPECIFICATIONS. 4) ALL MECHANICAL GROUNDING CONNECTIONS MADE THROUGHOUT THESE, DRAWINGS SHALL BE MADE WITH KOPR-SHIELD. THERE IS NO EQUIVALENT FOR THESE ANTIOXIDATION COMPOUNDS. NO OTHER COMPOUND WILL BE ACCEPTED. COAT ALL WIRES BEFORE LUGGING. COAT ALL SURFACES BEFORE CONNECTING. 5) FIELD QUALITY CONTROL - FIELD INSPECTION AND TESTING WILL BE PERFORMED AS REQUIRED: 6) THE CONTRACTOR SHALL VERIFY THAT THE SYSTEM IS EFFECTIVELY GROUNDED, MEETS NEC ARTICLE 250 REQUIREMENTS, AND IS ACCEPTABLE TO THE LOCAL UTILITY AND LOCAL AUTHORITY HAVING JURISDICTION. 7) THE CONTRACTOR SHALL MAKE ALL MEASUREMENTS REQUIRED TO TEST THE GROUNDING NETWORK SYSTEM. SYSTEM SHALL BE TESTED AT THE TIME OF INSTALLATION. 8) THE GROUNDING NETWORK SYSTEM TEST PROCEDURE SHALL COMPLY WITH NFPA 78 THREE POINT TECHNIQUE FOR GROUND RESISTANCE, EXCEPT AS MODIFIED HEREIN. 9) CONTRACTOR SHALL VERIFY THE ADEQUACY OF THE INSTALLED SYSTEM. CONTRACTOR SHALL CONDUCT "SITE RESISTANCE TO EARTH GROUNDING TESTING" SYSTEM 10) RECORD GROUND RESISTANCE PER CLIENTS COMPANY'S STANDARD. INSTALLED OHMS. 11) TEST SHALL BE WITNESSED BY CLIENT'S REPRESENTATIVE SHALL ACHIEVE A GROUND RESISTANCE OF LESS THAN 5 OHMS. TEST RESULTS SHALL BE SUBMITTED ON THE "GROUND RESISTANCE TEST FORM" TO THE CLIENT'S REPRESENTATIVE REPRESENTATIVE. 12) SUBMIT 2 COPIES OF THE GROUND RESISTANCE TEST FORM TO THE CLIENT'S REPRESENTATIVE REPRESENTATIVE. 3.8 CHECKOUT, TESTING, AND ADJUSTING A. CORRECTION/REPLACEMENT: AFTER TESTING BY CONTRACTOR, CLIENT'S REPRESENTATIVE, OR ENGINEER CORRECT ANY DEFICIENCIES, AND REPLACE MATERIALS AND EQUIPMENT SHOWN TO BE DEFECTIVE OR UNABLE TO PERFORM AT DESIGN OR RATED CAPACITY. B. POWER CONDUCTORS: CONTRACTOR SHALL CONDUCT A CONTINUITY & INSULATION TEST ON CONDUCTORS BETWEEN SERVICE DISCONNECT SWITCH & POWER CABINET. C. GROUNDING - IEEE FALL OF POTENTIAL TESTS: CONDUCT TEST WITH A AEMC MODEL #4500 TESTER. THE METHOD OF USING TWO AUXILIARY GROUND RODS (AS DESCRIBED IN I.E.E.E. STANDARD #81 - 1983, PART 1) SHALL BE USED. THE AUXILIARY TEST RODS MUST BE SUFFICIENTLY FAR AWAY FROM THE RODS SO THAT THE REGIONS IN WHICH THEIR RESISTANCE IS LOCALIZED DO NOT OVERLAP 3.9 SYSTEMS DEMONSTRATION A. INSTRUCT CLIENT'S REPRESENTATIVE'S REPRESENTATIVE(S) IN THE START-UP, OPERATION AND MAINTENANCE OF ALL ELECTRICAL SYSTEMS AND EQUIPMENT AS REQUESTED BY THE CLIENT'S REPRESENTATIVE REPRESENTATIVE. 3.10 CLEANING AND TOUCH-UP PAINTING A. GENERAL: PERIODICALLY REMOVE FROM THE PROJECT SITE, ALL WASTE, RUBBISH AND CONSTRUCTION DEBRIS ACCUMULATED FROM CONSTRUCTION OPERATIONS. THE PREMISES SHALL BE LEFT CLEAN AND FREE OF ANY DEBRIS AND UNUSED CONSTRUCTION MATERIALS PRIOR TO FINAL ACCEPTANCE. B. ELECTRICAL EQUIPMENT: REMOVE ALL DUST, DIRT, DEBRIS, MORTAR, WIRE SCRAPS, RUST, AND OTHER FOREIGN MATERIALS FORM THE INTERIOR AND EXTERIOR OF ALL ELECTRICAL EQUIPMENT AND ENCLOSURES, AND WIPE DOWN. CLEAN ACCESSIBLE CURRENT CARRYING ELEMENTS AND INSULATORS PRIOR TO ENERGIZING. 3.10 COAXIAL CABLE INSTALLATION A. THE COAXIAL CABLE SIZE SHALL BE AS SHOWN ON DRAWINGS. B. COAXIAL CABLE SUPPORTS. 1) SUPPORT COAXIAL CABLES INSIDE MONOPOLES WITH "KELLEM" GRIP TYPE PRODUCTS. 2) SECURE AND SUPPORT COAXIAL CABLES ON OPEN WAVEGUIDES STRUCTURAL TOWERS. 3) SECURE AND SUPPORT COAXIAL CABLES ON ICE BRIDGES AS INDICATED ON DRAWINGS. C. COAXIAL CABLE GROUNDING: 1) THE COAXIAL CABLES SHALL BE GROUNDED TO BUS BAR(S) AT THE ANTENNAS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. 2) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BAR AT THE BOTTOM OF THE TOWER OR MONOPOLE USING THE GROUNDING KITS SPECIFIED ON THE DRAWINGS. 3) THE COAXIAL CABLES SHALL BE GROUNDED TO A BUS BAR AT THE BULKHEADS USING THE GROUNDING KITS AS SPECIFIED ON THE DRAWINGS. DRAWING ABBREVIATIONS AFF ABOVE FINISH FLOOR LF LINEAR FEET AGL ABOVE GRADE LEVEL MW MICROWAVE AWG AMERICAN WIRE GAUGE MAX MAXIMUM AC AIR CONDITIONING MECH MECHANICAL ADJ ADJUSTABLE MFR MANUFACTURER APPROX APPROXIMATELY MGR MANAGER AZ AZIMUTH MIN MINIMUM BLDG BUILDING MISC MISCELLANEOUS CM CONSTRUCTION MANAGER MTL METAL CAB CABINET NEC NATIONAL ELECTRICAL CODE CLG CEILING NIC NOT IN CONTRACT CLR CLEAR NTS NOT TO SCALE CO COPPER N/A NOT APPLICABLE CONC CONCRETE OC ON CENTER COND CONDUIT OD OUTSIDE DIAMETER CONST CONSTRUCTION OP OVERHEAD POWER CONT CONTINUOUS OT OVERHEAD TELCO CPM CASCADIA PM OPP OPPOSITE D/C DRAFTER/CHECKER PM PROJECT MANAGER DEMO DEMOLISH PT PRESSURE TREATED DIA DIAMETER PLYWD PLYWOOD DIM DIMENSION PROD PROJECT DN DOWN PROP PROPERTY DTL DETAIL RO ROUGH OPENING DWG DRAWING ROW RIGHT OF WAY EA EACH RRU REMOTE RADIO UNIT ELECT ELECTRICAL REQ REQUIRED ELEV ELEVATION SS STAINLESS STEEL EQ EQUAL SF SQUARE FEET EQUIP EQUIPMENT SHT SHEET EXT EXTERIOR SIM SIMILAR FIN FINISH SPEC SPECIFICATION FLR FLOOR SQ SQUARE FT FOOT, FEET STL STEEL GC GENERAL CONTRACTOR STRUCT STRUCTURE, STRUCTURAL GWB GYPSUM WALL BOARD TOC TOP OF CONCRETE GA GAUGE TOM TOP OF MASONRY GALV GALVANIZE(D) THRU THROUGH GR GRADE TNND TINNED GRND GROUND UBC UNIFORM BUILDING CODE HVAC HEATING, VENTING & AIR CONDITIONING UNO UNLESS NOTED OTHERWISE HORIZ HORIZONTAL UP UNDERGROUND POWER HT HEIGHT UT UNDERGROUND TELCO IBC INTERNATIONAL BUILDING CODE VIF VERIFY IN FIELD ID INSIDE DIAMETER VERT VERTICAL IN INCH WP WATERPROOF INFO INFORMATION W/ WITH INSUL INSULATION W/O WITHOUT INT INTERIOR CL CENTER LINE JBOX JUNCTION BOX PL PROPERTY LINE LB(S) POUND(S) 'M 8760122ND AVE, NE KIRKLAND, WA 98033 PH: (425) 828-1008 tryoo . , -- 2_"r / 2. r?R2''2011 CPM PROJECT NO.: 3649 PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 H/CT 90% REVIEW 4 04-11-10 H/CT CLIENT COMMENT 5 04-19-11MH/CTI CLIENT COMMENT SUBMITTAL NO. DATE DIC DESCRIPTION 0 04-22-11MH/CT BP SUBMITTAL SITE NAME WAl GARDINER - LTE ATC SITE #82962 APN: SITE ADDRESS 1696 STATE HWY 104 QUILCENE, WA 98376 SHEET TITLE GENERAL NOTES SHEET NO. GN -3 APIA 2 7 2011 i JEFFERSON COUNTY r rT mlf,'llrY Ili �'FI.OPP,�FNI WA 1 GARDINER LTE n wireless ver, gn ATC SITE #82962 N wire ss /e CONSTRUCTION DRAWINGS Cascadia PM PROJECT DATA PROJECT CONTACTS DRAWING INDEX 8760122ND AVE, NE KIRKLAND, WA 98033 SITE ADDRESS: 1696 STAR ROUTE 104 GOVERNING CODES APPLICANT SHEET DESCRIPTION PH: (425) 828-1008 QUILCENE, WA 98276 VERIZON WIRELESS IBC -2009, INTERNATIONAL BUILDING CODE W/ LOCAL AMENDMENTS 3350 161 st AVENUE SOUTH T-1.0 TITLE SHEET LATITUDE: 470 55' 17.32" N BELLEVUE, WA 98008 A-1.0 OVERALL SITE PLAN LONGITUDE: 1220 51'31•.5" W NEC -2008, NATIONAL ELECTRICAL CODE PROPERTY OWNER A-2.0 ENLARGED SITE PLAN JURISDICTION: JEFFERSON COUNTY A.D.A. COMPLIANCE POPE RESOURCES INSTALLATION IS UNMANNED AND NOT FOR HUMAN HABITATION. C/O OLYMPIC RESOURCE MGMT A-3.0 EXISTING & PROPOSED EAST ELEVATION APN: 801181001 HANDICAP ACCESS IS NOT REQUIRED PER A.D.A. ATTN: LAND RECORDS A-4.0 ANTENNA DETAILS 19245 10TH AVENUE NE GROUND ELEVATION: 714.00'AMSL POULSBO, WA 98370 A-4.1 MICROWAVE ANTENNA DETAILS TOP OF STRUCTURE: 177AGLI•ALW � 4a,0 TOWER/POLE OWNER A-4.2 DIPLEXER & TMA DETAILS OCCUPANCY GROUP: U FAA STUDY: AMERICAN TOWER CORP. 10 GENERAL NOTES CONSTRUCTION TYPE: TELECOMMUNICATIONS 2009-ANM-1 971 -OE 10 PRESIDENTIAL WAY ZONING: COMMERCIAL FOREST WOBURN, MA 01801 GN -2 GENERAL NOTES 41 LAND USE DESIGNATION: UNMANNED TELCOM PH: 781.926.4663 GN -3 GENERAL NOTES PROPERTY DESCRIPTION: S18 T28 R1 ALL OF SECTION (LESS TAX 1 & R/W) S/EASE. FAX: 781.926-4555 SECTION 18, QTR SECTION NE 1/4, TOWNSHIP 28N, RANGE IW LEASING CONSULTANT 1-2-7 CASCADIA PM 8760 122ND AVE NE Contact APR 2 2011 AREA MAP KIRKLAND, WA 98033 1 . I : Lit 3'/91-46-50 dhanges BILL POWELL or revl"iions to plans PH: 425.828.1008 CPM PROJECT NO.: 3649 CONSULTANT �6Rcl tv CASCADIA PM 8760 122ND AVE NE KIRKLAND, WA 98033 APPROVAL LIST GIBRAN HASHMI PH: 425.828.1008 TITLE SIGNATURE DATE PRELIMINARY NO. DATE D/C DESCRIPTION 0 01-17-11 H/CT 90% REVIEW 4 04-11-10 H/CT CLIENT COMMENT 1 5 104-19-11 H/CT CLIENT COMMENT CONSULTING ENGINEER ! %� SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11 H/CT BP SUBMITTAL APR 2 7 20,11 Ll Lj ITP- PROPERTY OWNER VECTOR STRUCTURAL ENGINEERS SITE ACQUISITION :> 0 9138 STATE STREET, SUITE 101 y"' a SANDY, UT 84070 ZONING P jj PROJECT LOCATION PH: 801.990-1775 RF ENGINEER SUBMITTAL NO. DATE D/C DESCRIPTION 0 04-22-11 H/CT BP SUBMITTAL APR 2 7 20,11 Ll Lj ITP-