HomeMy WebLinkAboutBLD2016-00351 - POLE BLDG 4���,ON caC • JEFFERSON COUNTY 110 r` {{` c DEPARTMENT OF COMMUNITY DEVELOPMENT -r �c 621 Sheridan Street I Port Townsend, WA 98368 360-379-4450 I email: dcd@co.jefferson.wa.us tyxflN 3�"p www.co.jefferson.wa.us/commdevelopment S BUILDING PERMIT PERMIT#: BLD16-00351 Received Date: 8/3/2016 SITE ADDRESS: 523 WHISPERING CEDAR LN Issue Date 11/15/2016 CHIMACUM, 98325 Expiration Date 11/15/2017 OWNER: TONY DUNN PHONE: 6025791036 23169 N 79TH AVE PEORIA AZ 85383-1690 SUBDIVISION: PARCEL NUMBER: 901354010 Section: 35 Township: 29 N Range: 1V1 CONTRACTOR: OLYMPIC STEEL Contractor's License OLYMPSL900NZ DICK SHIPMAN 271 CUB RD PORT TOWNSEND WA 98368 PHONE: (360)385-6059 PROJECT DESCRIPTION: NEW POLE BUILDING - NO HEATING - NO PLUMBING TYPE OF WORK GAR SQUARE FOOTAGE: TYPE OF IMP NEW MAIN: VALUATION 68,888.00 ADD'L: HEAT TYPE: CODE EDITION: 2012 HEAT BASE: HEAT TYPE: OCCUPANCY: U-1 UNHEATED: #OF STORIES: OCCUPANCY: OTHER: CONST TYPE: 5N GARAGE: 2,100 SHORELINE: CONST TYPE: DECK: SETBACK: BANK HEIGHT: SEWAGE DISPOSAL: WATER SYSTEM: Type Amount Paid By: Date: Receipt: BEDROOMS: BATHROOMS: Permit $748.00 HAC2 08/03/16 165530 Exist: Exist: Plan Check $486.20 HAC2 08/03/16 165530 Prop: Prop: Consistency Review $255.00 HAC2 08/03/16 165530 Total: Total: Scanning Fee $21.00 HAC2 08/03/16 165530 State Building Code $4.50 HAC2 08/03/16 165530 EH SEP/RES Rev $129.00 HAC2 08/03/16 165530 Total: $1,643.70 RI05.5 Expiration. Every permit issued shall become invalid unless the work authorized by such permit is commenced within 180 days after its issuance, or if the work authorized by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. HEALTH DEPARTMENT AND PUBLIC WORKS APPROVAL REQUIRED PRIOR TO FINAL INSPECTION THIS PERMIT IS VALID FOR ONE YEAR OR IT MUST BE PROPERLY RENEWED BUILDING INSPECTION HOT-LINE 379-4455. Request must be received by 3pm the day before the inspection is needed. Final Inspections require 24 hour notice. Office Hours 9:00 am -4:30 pm MONDAY- THURSDAY HOT LINE AVAILABLE 24 HOURS A DAY SPECIAL CONDITIONS APPLY- SEE ATTATCHED Jefferson County Building Divn Permit Numb, BLD16-00351 00351 Applicant: DUNN PERMIT INSPECTION APPROVALS Applicable Code: 2012 International Building Codes To schedule inspections, call (360)379-4455 no later than 3:00PM the day before the inspection is needed. Requests received after 3:00 PM will not be scheduled for the next day's inspections. ELECTRICAL PERMITS are issued by the Washington State Department of Labor& Industries. The electrical permit must be signed off by the State Inspector prior to the County's Framing Inspection Inspection Item Date Approval Signature Notes Setbacks ci/ice/i J f .. Post Holes Straps(hold downs) Ext. Shear Wall Nailing Framing I ,- ----- 6./ 411 Blocking , A final inspection will not be scheduled until the following are completed and signed off by the applicable Department: • Building Permit Conditions are met • Septic Permit Final/Complete for any building containing plumbing • Land Use Conditions met and signed off • Public Works Permit Final(where applicable) FINAL INSPECTION 101,5' 1-1 I. ---- I FINAL INSPECTION MUST BE APPROVED PRIOR TO BUILDING BEING OCCUPIED THIS PERMIT IS VALID FOR ONE YEAR • • CONDITIONS for Building Permit# :BLD16-00351 1.) The structure identified on the site plan as 20x12 building with no plumbing and no electricity located due south of the well and within the 100'well raduis was not permitted by the county. The approval does not also approve the use of this structure as anything other than storage-no occupancy is permitted. If structure is occupied a building permit and septic approval will be required. 2.) The application was reviewed by the Jefferson County Department of Community Development staff on 08/11/2016 for the potential presence of Environmentally Sensitive Areas (ESAs) under the provisions of the Unified Development Code (UDC). After an initial Geographic Information Systems mapping review and an investigative site inspection, the following ESAs were confirmed to be present on the subject property: Type Non-Fish bearing stream Fish and Wildlife Habitat Conservation Area. 3.) A Non-Fish Bearing Stream (Fish and Wildlife Habitat Conservation Area) has been identified on the subject property. The stream will require a buffer of 50 feet. The buffer shall be measured horizontally from the Ordinary High Water Mark(OHWM). Fish and Wildlife Habitat Areas shall also have Buffers and Building Setbacks established. 4.) Stream Buffers are areas that shall be maintained in their natural condition, however, minor pruning or alteration of vegetation may be permitted as long as the function and character of the buffer are not diminished. 5.) An additional setback of five (5)feet is required from the edge of the buffer area to the proposed pole building. 6.) Jefferson County has determined that the use of real property for agriculture and forestry operations is a high priority and favored use in the county. The county will not consider to be a nuisance those inconveniences or discomforts arising from such operations, if such operations are consistent with commonly accepted best management practices in compliance with local, state, and federal laws. If your real property includes or is within five hundred (500)feet of real property designated as Rural Residential 1:10 or 1:20, Rural Industrial, Rural Commercial, Agriculture, or Forestry, you may be subject to inconveniences or discomforts arising from such farming and forestry operations, including but not limited to noise, tree removal, odors, flies, fumes, dust, smoke, the operation of farm and forestry machinery during any 24-hour period, the storage and disposal of manure, and the application of permitted fertilizers and permitted pesticides. One or more of these inconveniences may occur as a result of agricultural and forestry operations which are in conformance with existing laws and regulations. 7.) The applicant is proposing to create or add 3,500 square feet of impervious surface and 3,500 square feet of land disturbing activities. JCC 18.30.060 and 18.30.070 require the project applicant submit a stormwater plan meeting Minimum Requirements#1 through #5 of the Department of Ecology Stormwater Management Manual for Western Washington. The stormwater plan shall address measures to control stormwater, erosion and sediment during construction and shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 8.) The project shall adhere to the Best Management Practices (BMPs)to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 9.) This approval is for a new unheated and unplumbed pole building only. Any future permits on this site are subject to review for consistency with applicable codes and ordinances and does not preclude review and conditions which may be placed on future permits. 10.) The revised site plan as submitted with the new pole building application on NoOiber 14, 2016 has been reviewed for consistency under the UDC, and has been approved by Jefferson County Department of Community Development. Any modifications, changes, and/or additions to the stamped, approved site plan dated November 14, 2016 shall be resubmitted for review and approval by Jefferson County Department of Community Development. 11.) EDB 12.) Approval of this permit does not provide any assurance of future approvals for onsite sewage disposal on the property or use of any existing septic systems. Actions taken to date and proposed as part of this project may limit or prevent future development of an onsite sewage system. Future proposals must meet current code at the time of application. 13.) No plumbing has been reviewed or approved for this project by Jefferson County Public Health. Additional requirements may apply if plumbing is proposed. \\tidemark\data\forms\F_BLD_Permit_Bldg.rpt 11/15/2016 Cf* 0 _. , - rJ , - ' Jam_ Crl S *-- \i" --71 3 >. i n . n . � A - • 9 , gc.3 ...) Lp C6 > 3 9 r __s - —: tr"(--.-.-)P Q No N ..,) P i ,s.. --.0 0 • — . ,.5 -k-- nrr s -Li --, 0 s J n A X ri g v V 1. I� T ! - P 1 CEJ 1^ �' ' m. 1 ,--ei-\:--Y ....\--- �\ " -� \n - U Jim Coyne From: Seth Light <actengr@gmail.com> Sent: Monday, January 23, 2017 5:50 PM To: Jim Coyne Cc: dshipman@olypen.com Subject: Permit# BLD16-00351 (for Tony Dunn, Chimicum, WA) Hi Jim, Since Mr. Dunn will be pouring a concrete slab at the proposed building, we are revising our previous design with the slab included. (When we designed the original pier only foundation, we didn't know a slab would be present.) Having a slab present allows us to go with shallower piers and 6'-0" deep piers will be acceptable for the "Clearspan Frame Column Bases" noted on detail Z/2. We will be finishing up the revised drawings in the next day or so. If you have any questions regarding this, please reply. Thanks, Seth Light, S.E. ASK4 Engineering, Inc. Exclusive Engineers for OutBack Steel Buildings TM throughout the USA 1