Loading...
HomeMy WebLinkAboutMLA17-00064 septic inspection reportSho/d Excavating Ina, PO Box 179 360-385-0480 Port Hadlock, WA 98339 mail To: ANGELA JOHNSON 7530 26TH AVE NW SEATTLE, WA 98117 PROPERTY INFORMATION Location: 312403 HWY 101 TaxID:502291005 Use: Owner. ANGELA JOHNSON Fold ri ��r�'i�I_��r��il_rr�:�r,��_rr;il�;rr��•f=�r�;n:f=j, �� rfe1:I11:141*1 � Here Inspected: 10/16(2015 - Inspection Type: PROPERTY SALE - Correction Status: No corrections made Company: Certification - Level 2 Shold Excavating Inc. Work Performed By., Submitted 11(1812015 by: Martin Fugere Martin Fugere This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development. COMMENTS & GENERAL INSPECTION NOTES Deficiencies Noted: deficiencies must be corrected to ensure proper longevity of the Onsite Sewage System. 1. Risers need to be installed before next inspection 2. There is root intrusion in the Septic Tank and Pump Chamber 3. There is no structure connected to the system, so an accurate evaluation of the drainfleld could not be completed GENERAL SITE & SYSTEM CONDITIONS The General site and System uonanions were: All Components accessible for maintenance, secure and in good condition: Surfacing effluent from any component (including mound seepage): Components appear to be watertight - no visual leaks: Improper encroachment (roads, buildings, to onto component(s): Component settling problems observed: Abnormal ponding present for one or more of the disposal components: Subsurtace components adequately covered Owner compliance issues noted Site maintenance required (e.g. Landscape maintenance) If yes, describe in comments: Occupant compliance problem (occupant not operating the system properly). If YES, describe in notes: If deficiencies were identified on last inspection were they corrected before or during this inspection? (If NO, describe in notes, NA = no deficiencies on last report): OSS Components, structures and appurtenances located per as-built/record drawing (reference Septic Permit # in notes). If NO, describe in notes and if no as -built exists or changes made, state NO and provide record to Health Dept, Alterations made to the OSS (valves adjusted, timer settings modified, ports installed, etc.) (If YES, iescribe in notes): The houselstructure was vacant or used infrequently, assessment of the drainfleld was not possible. s the SEP case in a finaled/completed status? (if NO explain in comments) ONSITE SEWAGE SYSTEM INSPECTION DETAIL NO - Deficient NO YES NO NO NO YES NO NO NO NFA YES NO YES- YES ES- rYES ReportlD: 471788 View inspection reports online at www.onlinerme.com Page 1 of 2 Fold Here TANK: Septic Tank - 2 Compariment This Component was: Fully Inspected Component appears to be functioning as intended: YES Effluent level within operational limits (if NO explain in comments): YES .All required baffles in place (NIA = No baffles required): YES Effluent Filter Cleaned (N/A = Not Present): N/A Effluent filter/screen needed cleaning on arrival N/A Compartment 1 Scum accumulation (Inches, if other specify): 0 Compartment 1 Sludge accumulation (Inches, if other specify): 0 Compartment 2 Scum accumulation (Inches, if other specify): 0 Compartment 2 Sludge accumulation (Inches, if other specify): 0 Pumping needed: NO ReportlD: 471788 View inspection reports online at www.onlinerme.com Page 1 of 2 Fold Here Approximate Gallons to be pumped (if needed) by Certified Pumper: o TA NK.Pump Ta f A This component was: Fully Inspected Component appears to be functioning as intended: YES Compartment 1 Scum accumulation (Inches, if other specify): o Pump vault screen needed cleaning on arrival NO Compartment 1 Sludge accumulation (Inches, if other specify): 0 Pump Vault Filter cleaned (N/A = not present): NO Pumping needed: NO Approximate Gallons to be pumped (if needed) by Certified Pumper: 0 This component was: Fully Inspected 'Panel functioning (including alarm): YES Pump 1: on minutes (override in parentheses - if present): 3 Pump 1: off hours (override in parentheses - if present): B Pump T gallons per dose (override in parentheses - if present): Pump 1: ETM hours (override in parentheses - if present): 1:O8 (Pump 1: Cycle Count (override in parentheses - if present): 41 Pump 2: on minutes (override in parentheses - if present): Demand Pump 2: off hours (override in parentheses - if present): Demand Pump 2: gallons per dose (override in parentheses - if present): N/a (Pump 2: ETM hours (override in parentheses - if present): 1:41 Pump 2: Cycfe Count (override in parentheses - if present); 87 This component was: Fully Inspected Component appears to be functioning as intended: YES Controls functioning: YES Dose setting different than original (If YES, detail in comments) NO Dose setting adjusted to meet as-built/record drawing specifications (by the O&M Specialist) NO Tested gallons per minute flow: 40 This component was: Fully Inspected Component appears to be functioning as intended: YES Average squirt height (if performed) (feet, if other specify): 10' Lateral lines flushed: r YES 'This component was: Fu4Inspected Component appears to be functioning as intended: YES Lateral lines flushed: YES Average squirt height (if performed) (feet, if other specify): 9. Ponding present? If YES explain in comments: NO This report indicates certain characteristics of the onsde sewage system at the time of visit. In noway is this report a guarantee of operation or future performance. ReportlD: 471788 View inspection reports online at www.onlinerme.com Page 2 of 2