HomeMy WebLinkAboutC6_2 Typ Residential LID DetailsOVERFLOW CONTROL BACK-UP OVERF CONTROL TREN( INFILTRATION) FOOTPRINT OF FROM PLANTEI IiLCM N UU I t I T r.) rIrC L/AIU r-L/A I( I T r.) PLAN VIEW BUILDING DOWNSPOUT (TYPICAL) BEEHIVE GRATE OR EQUIVALENT (OVERFLOW CONTROL) Q 0 w FOR EROSION CONTROL LU e INSTALL 4 SQUARE FEET OF 3" WASHED ROCK WALL MAY BE CONSTRUCTED AROUND DOWNSPOUT OUT OF VARIOUS MATERIALS 18" COMPOST LINE PLANTER WITH AMENDED SOIL WATERPROOF MEMBRANE ` ;' :.; : ;.Y �. ;: ••; -; ` j�\/�\/�\/�\/�\j, j�/j�/j\ ':.: FILTER FABRIC (NON —WOVEN) OR 4 PEA O . \//\//\//\//\//\, ": •:•` GRAVEL LAY E R \ `/ FOOTING DRAIN / / / WASHED \//\/�// ROCK RESERVOIR \\/\\/\\\M\ 1\\1 j` ( I N F I LTRATI ON ZON E ) INFILTRATIONSZZ' 6" AREA FOOTPRINT Notes: 1. Sized to handle 100 year storm event 2. Soil group B 3. Depth of washed rock reservoir and compost amended soil may vary to fit site conditions 4. Raingarden area (SF) is the footprint of infiltration zone 5. Raingardens are sized based on a percentage of the impervious surface area Raingarden Sizing Chart (Raingarden sized based on 3.5% of impervious area) Impervious Surface Area (SF) 25 50 100 250 500 1000 2500 5000 Raingarden Area (SF) 0.88 1.75 3.5 8.75 17.5 35 87.5 175 CROSS SECTION VIEW TYPICAL LOT RAINGARDEN PLANTER BOX NTS R" Tr)P I AYFR (-nngPOST AMENDED SOIL MIX -O TOP 12" OF UNDISTURBED TOPSOIL) NOTE: COMPOST AMENDED SOIL MIX SHALL BE 50% C33 SAND AND 35% GRADE "A" COMPOST & 15% LOAMY TOPSOIL ►RTED SOIL BASE ,TYPICAL COMPOST AMENDED SOIL SECTION NTS 6" PEI PIPE JTAINMENT BERM 18" COMPOST AMENDED SANDY SOIL 4" LAYER OF PEA GRAVEL INFILTRATION ZONE =24" WASHED ROCK (3/4" — 1-1/2") AND/OR EXISTING SANDY GRAVEL SOIL, i > 8" /hr UINUIJ I UKCSCU JUILJ CROSS SECTION VIEW Notes: 1. Sized to handle 100 year storm event 2. Soil group B 3. Depth of washed rock reservoir and compost amended soil may vary to fit site conditions 4. Raingarden area (SF) is the footprint of infiltration zone 5. Raingardens are sized based on a percentage Typical Raingarden Sizing Chart (size based on 3.5% of impervious area) Impervious Surface Area (SF) 100 500 1000 2500 5000 7500 10000 15000 Raingarden Area (SF) 3.5 17.5 35 87.5 175 262.5 350 525 TYPICAL LOT RAINGARDEN NTS 6" DEPTH POROUS CONCRETE SURFACE (PORTLAND CEMENT CONCRETE MIX) 6" DEPTH, 1-1/4" CHIPPED ROCK (DRAINAGE "RESERVOIR" BASE COURSE, MIN 15% VOIDS, MIN 10"/HR INFILTRATION RATE) EXISTING SOIL MINIMAL COMPACTION(92%±) TO RETAIN POROSITY AND PERMEABILITY *NOTE: , I 1V a 4" POROUS CONCRETE PAVEMENT MAY BE >>> >> >>>>>>>>>>>>>>>>>>>>>> USED FOR DRIVEWAYS, PATIOS AND > > > > > > > > > > > > > > > SIDEWALKS WITHIN LOTS. > > > > > > > > > > > > > > > > > > > > > > > > > > > > ENGINEER: M. BUEHRER DESIGNED BY.- M. BUEHRER DATE.- 5-15-06 DRAWN BY.- R. KOPKA DATE: 5-15-06 CHECKED BY: M. BUEHRER DATE: 5-15-06 PROD. MNGR: M. BUEHRER PROJ. N0: 445dbg 1 5-07-07 MGS MSB REVISED DETAILS FILE NAME: 445—RPD_LIDetails.dwg NO. DATE BY APPR. REVISION SCALE: AS SHOWN GEOTEXTILE TYPICAL POROUS CONCRETE SECTION ENGINEERING] 2020 ENGINEERING, INC. 700 DUPONT STREET POST OFFICE BOX 1621 BELLINGHAM, WA. 98227-1621 USA P: (360)671-2020 F: (360) 671-0322 www.2020engineering.com NTS PAVER EDGE RESTRAINT PER MANUFACTURERS RECOMMENDATIONS. a aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa �aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaa4a4aaa4a4aaaQaQaaaaa4aaaaaQaaaa aaaaaQaaaaaaaaaaa4aaaaa4aaa4a4aaa4a4aaaa aaa4a4aaa4aQaaaQaaaaaaaaaaa4a4aaa4a4aaaa A TYPICAL DRIVEWAY SECTION NTS PAVER EDGE RESTRAINT PER MANUFACTURERS RECOMMENDATIONS. aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa aaaQaQa4aQaQaaaQaQaaaQaQaaaQaQaaaQaQaaaa TYPICAL SIDEWALK OR PATIO SECTION B NTS -PAVERS (3%$") -1" BEDDING SAND 6" (MIN.) COMPACTED DEPTH OF 1 %4" MINUS CRUSHED ROCK BASE - GEOTEXTILE COMPACTED SOIL SUBBASE AND/OR SUBGRADE. PAVERS (2%") — 1" BEDDING SAND — 4" (MIN.) COMPACTED DEPTH OF 1 X" MINUS CRUSHED ROCK BASE GEOTEXTILE COMPACTED SOIL SUBBASE AND/OR SUBGRADE. ,TYPICAL POROUS PAVER SECTION y NTS PROPERTY LINE PRESERVED NATIVE VEGETATION BUFFER, MINIMIZE DISTURBANCE FOR DRIVEWAY CONSTRTUCTION LEGEND STREET AND ALLEY PAVEMENT (CONCRETE, ASPHALT OPTIONS) LLLJ RAINGARDEN RAINGARDEN PLANTER BOX POROUS PAVERS (OPTIONAL) OR POROUS CONCRETE PAVEMENT COMPOST AMENDED SOIL �—� ROOF DRAIN CONNECTION i� DOWNWARD SLOPE ORAIN BARREL 6 TYPICAL SITE DRAINAGE PLAN �,:J_ NTS DISCOVERY BAY GOLF CLUB SHEET: WeFore 7401 CAPE GEORGE ROAD TYPICAL L.I.D DETAILS C6.2 PORT TOWNSEND, WA 98368 (425)822-5242 RESIDENTIAL LOTS OF 37