Loading...
HomeMy WebLinkAboutBLD2019-00157 - MECHANICALI o gJ JEFFERSON COUNW DEPARTMENT OF COMiJIUNITY DEVELOPMENT 621 Sheridan Street I PortTownsend, WA 98368 360-379-4450 | email: dcd@co.jefferson.wa.us www. co.jefferson.wa. us/com mdevelopme nt TEGHAIIIGAL AiID DETOLITIOil PERTIT PERMIT #: SITE ADDRESS: APPLICANT: SUBDIVISION: PARCEL NUMBER: CONTRACTOR: BLD19-001s7 91 E MIDDLEPOINT RD PORT TOV\NSEND, 98368 LAURA J TUCKER 91 E MIDDLEPOINT RD PORT TO\ /NSEND WA 98368-9636 Received Date lssue Date 4117t2019 4t1712019 001053018 CASCADIA SOLAR HANS FREDERICKSON Contractor'sLicense FREDEE-892RH Expires 1211912019 PHONE: 360-280-5956 Block: Lot Section: 5 Township: 30N Range: 1W PHONE: 360-930-6993 PROJECT DESCRIPTION SOLAR SYSTEM THIS PERMIT IS VALID FOR ONE YEARAND IS NOT RENEWABLE. THE FINAL INSPECTION MUST BE SCHEDULED AND PASSED WITHIN THAT YEAR. THE EXPIRATTON DATE IS 411712020. Final Approval , dsol,A BUILDING INSPECTION HOT-LINE 379.4455. REQUESTS MUST BE RECEIVED BY 3 PM THE DAY BEFORE THE INSPECTION IS NEEDED. Office Hours 9;00 a.m. - 4:30 p.m. Monday - Thursday \\tidemark\data\forms\F_BLD_Permit_Propane. rpt HOT LINEAVAII.ABLE 24 HOURSA DAY 4t17t2019 REQUIRED INSPECTIONS: lnstallationperManufacturerSpecificationS/co: Orr,trNG PERMTT APP.,"to* Jefferson County Department of Community Development 621 Sheridan Street Port Townsend, WA 98368 BLDl9-00157 Review Type: PERMIT #: SITEADDRESS: OWNER: SUBDIVISION: PARCEL NUMBER. BLD19-00157 91 E MIDDLEPOINT RD PORT TOWNSEND, 98368 LAURA J TUCKER 91 E MIDDLEPOINT RD PORT TOWNSEND WA 98368-9636 ReceivedDate: 4l'1712019 PHONE: 360-280-5956 Block: 001 05301 8 Section: 5 Township: 30 N Range: 1V1 Lot: CONTRACTOR REPRESENTATIVE: CASCADIASOLAR HANS FREDERICKSON PHONE: 360-930-6993 Contractor's License FREDEE.892RH Expires 1211912019 PHONE: PROJECT DESCRIPTION: SOLAR SYSTEM TYPE OF WORK TYPE OF IMP VALUATION CODE EDITION: OCCUPANCY: OCCUPANCY: CONST TYPE: CONST TYPE: BEDROOMS: Exist: Prop: Total: 2015 SEWAGE DISPOSAL: WATER SYSTEM: BATHROOMS: Exist: Prop: Total: Approved/Date APPROVED APR I 7 20S Jefferson County DCD SQUARE FOOTAGE: MAIN: ADD'L: HEAT BASE: UNHEATED: OTHER: GARAGE: DECK: Type HEAT TYPE: HEAT TYPE: # OF STORIES: SHORELINE: SETBACK: BANK HEIGHT Amount Paid By: Date: Receipt NON NEW Permit Scanning Fee Tech Fee $184.00 JLA $23.00 JLA $10.35 JLA 04t17t19 04117t19 04t17t19 1 8381 8 1 8381 I 1 8381 8 Total:$2r7.35 \\tidamarlz\r{a+a\fnrmc\tr Ell l'l Ann Plr{ rn+n ta'7 trdl0 o o JEFFERSON COUNTY DEPARTMENT OF COMMUNITY DEVELOPMENT 621 Sheridan Street I Port Townsend, WA 98368 360-3794450 | email: dcd@co.jefferson.wa. us www. co.jefferson.wa. us/com mdevelopment MEGHANIGAL AND DEMOLITION PERMIT PERMIT #: SITE ADDRESS: APPLICANT: SUBDIVISION: PARCEL NUMBER CONTRACTOR: BLD19-00157 91 E MIDDLEPOINT RD PORT TOWNSEND, 98368 LAURA J TUCKER 91 E MIDDLEPOINT RD PORT TOWNSEND WA 98368-9636 Received Date lssue Date 4t17t2019 4t17t2019 001 05301 8 CASCADIA SOLAR HANS FREDERICKSON Contractor'sLicense FREDEE.892RH Expires 1211912019 PHONE: 360-280-5956 Block: Lot: Section: 5 Township: 30N Ranqe: 1W PHONE: 360-930-6993 PROJECT DESCRIPTION: SOLAR SYSTEM THIS PERMIT IS VALID FOR ONE YEARAND IS NOT RENEWABLE. THE FINAL INSPECTION MUST BE SCHEDULED AND PASSED WITHIN THAT YEAR. THE EXPIRATION DATE IS 411712020. REQUIRED INSPECTIONS: lnstallationperManufacturerSpecifications/Co: TanULine/Appliance FinalApproval BUILDING INSPECTION HOT.LINE 3794455. REQUESTS MUST BE RECEIVED BY 3 PM THE DAY BEFORE THE INSPECTION IS NEEDED. Office Hours 9:00 a.m. - 4:30 p.m. Monday - Thursday \\tidema rk\d ata\form s\F_BLD_Perm it_Propa ne. rpt HOT LINE AVAILABLE 24 HOURS A DAY 4t17t2019 oa DEPARTMENT OF COMMUNITY DEVELOPMENT 621 Sheudan Strcet, Port Townsend, V'-\ 98368 Tel 360.379.4450 | Fax 360.379.445t !['eb: v,rww.co.iefferson.\r,a.us / communitydevelopmen t E-mail: dcd@co.icfferson.wa.us MECHANICAL PERMIT APPLICATIO Steps in the Permit Process: -Review required submittal items to ensure all information is completed prior to -Mechanical Permits can be mailed into our office-and do not require an appointment. -Fees are due at time of subm Mechanical rmits are nera issued within 5 business d ls this application for use in a Mobile / Manufactured Home?* lf Yes: A permit from Washington State Department of Labor and lndustries, !!g! Jefferson County, is required for appliances installed within a mobile/manufactured home. L&l - 360-417-2702* tf No: Complete this form and make an appointment to submit to Jefferson County Permit Tech 350-379-4450 Required Submittal ltems - for propane tank only General Site plan - showing propane tank, lines, and distance from tank to all existing structures. Required Submlttal ltems - for roof mount Solar Panel installation only (ground mount complete CAM) ,/ Complete first page and signature block only of Mechanical Permit Application A complete solar panel supplemental application. tra 6) !mv f tr D trGtr[V APR I 7 2019 tr Date: 41 tt / r) fl: cu bztt ls tOReceipt #: t t}For Department Use Only Related #s: Site lnformation Assessor Tax Parcel Number: 001 053018 Site Address and/or Directions to Property: 91 E Middlepoint Rd, Port Townsend, WA 98368 Access (name of street(s) from which access will be gained: E Middlepoint Rd Description of Work: lnstall 9.6 KW solar electric PV system with 32 Silfab Solar 300 watt modules Property Owner Name: Address: Phone #: Laura Tucker/Hank Walker 91 E Middlepoint Rd, Port Townsend, WA 98368 360-280-5956 Applicant / Contractor: Authorized Atent/Representative Name: Phone #: License f:FREDEE-892RH Frederickson Electric - Cascadia Solar 36S930-6993 E-mai I Ad d ress: dave@fredelectric.corn Expiration Date:1211912019 MechamcalApplication 1 E-ma i I Add ress: ltucker@berkeley.edu Heat Source Electric Heating Oil Propane*Wood tr o lnstallation manual must be-on site at time of inspection or a re-inspection fee will be charged. By signing this application form, the owner/agent attests that the information provided herein, and in any attachments, is true and correct to the best of his, her or its knowledge. Any material falsehood or any omission of a material fact made by the owner/agent with respect to this application packet may result in making any issued permit null and void. I further agree to that all activities I intend to undertake or complete associated with this permit will be performed in compliance with all applicable federal, state and county laws and regulations and I agree to provide access and right of entry to Jefferson County and its ernployees, representatives or agents for the sole purpose of application review and any required later inspeclions. Applicant may request notice of the County's intent to enter upon the property for visits related to this application and subsequent permit issuance. o Property er Signatu rint Name Laura Tucker/Hank Wal ker Date:0/.l16l20't9 lndicate Quantity of NEW Fixture Types Below *Propane is prohibited in hazardous locations such as basements or pits or anywhere " heavier-than-air" gas can unsafely collect. *Propane tanks over 125 gallons require a minimum setback of 10 ft. from property line and buildings, and a site plan must be submitted with the application showing the setbacks. lf propane tank is over 5@ gallons, a site plan is required to accompany this application, and a separate Fire Code approval is also required. Quantity Fixture Type Description Fan Bath Fan and/or Exhaust Fan Clothes Dryer Clothes Dryer with Exhaust Vent Cook Stove Cook Stove, Range Hood Exhaust Fireplace - Gas Fireplace-Gas or Gas Log lnsert Fireplace - Wood Fireplace-wood, Wood Stove, or Pellet Stove Electric Furnace Electric Furnace or HP +/- Ducting Propane (LP) Gas Furnace Propane Furnace +/- Ducting Water Heater - Gas Gas WH Vent and Combustion Air Gas Pipe System Gas Pipe System LPG/Oil Propane Tank LP FuelTank (# gallons: ) Heat Pump Generator Building Permit Fees MgChanical Pgrmit fee ltank swap, woodstove, furnace, roof -sotar panel, etc )s184.00 Propane - Lines, tank, and appliance (add'l SSZ.OO) Project Scanning Fee s23.00 Technology Fee -5%s10.3s Total Feesr F Lt1 7r +Additional fees may apply Mecharucal Application 2 Air Conditioner OFFICE USE ONLY o o DEPARTMENT OF COMMUNITY DEVELOPMENT 621 Sheridan Street, Port Townsend, WA 98358 Tel: 360.379.4450 | Fax: 360.379.4451 Web : www.co. iefferson.wa.us/communitvdevelooment E-mail : dcd @co. iefferson.wa.us EXPEDITED PERM ITTING CHECKLIST FOR RESTDENTIAL PHOTOVOTTAIC SYSTEMS: ROOFTOP MOUNTED Project Applicant:Frederickson Electric - Cascadia Solar Site Owner Name:Laura Tucker - Hank Walker Project Address:91 E Middlepoint Rd, Port Townsend, WA 98368 PV system description:9.6 kW grid-tiqd solar electric PV system @ nrolect tnformation Determine if your proiest needs a building permit (check all that apply): lf you answered yes to all of the above questlons, an over-the-counter permlt ls authorlzed. @ SuUmit this Checklist and Mechanical Permit Application and Site Plan to: I attest that all information in this checklist is accurate to the best of my knowledge. Applicant Signature C 6q/k4 Date:4/16/20'19 \ Applicant Name (Please Print): David C. Campbell, Jr. Solar Project Manager, Cascadia Solar Yes No l. PV system is designed and proposed for a structure previously built to code, 2. PV system is designed for rooftop of a building in general compliance with applicable codes. 3. Mounting system is engineered and designed for PV.,/ 4. Rooftop is made from lightweight material such as shingles.{ ,/5. PV system has been pre-approved by electrical permitting agency 6. To address uplift, panels are mounted no higher than 18" above the surface of the roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. T 7. Total dead load of panels, supports, mountings, raceways and all other appurtenances weigh no Etr No rnore than three and one-half (3.5) pounds per square foot (PSF) Frameless panels on at least 3/12 pitch roof weighing no more than four and one-half (4.5) PSF Frameless panels on at least 5/12 pitch roof weighing no more than five (5.0) PSF one of the following. lf YES, indicate which:more than V tr 8. Supports for solar panels are installed to spread the dead load across as many roof-framing members as needed to ensure that at no point are loads in excess of fifty (50) pounds are created. V tr {9. Attachment to the roof is specified by the mounting system manufacturer 10. Method and type of weatherproofing roof penetrations is provided 11. Home is code compliant to setbacks and height, or code allows expansion of nonconformity for solar panels.IA t_J ,/12. Panels are mounted no higher than the roof ridge or apex of roof (applies only to pitched roofs) IIII t{tta Y a