HomeMy WebLinkAbout6_List of Req, Maps, BuoyPROGRAMMATIC ENDANGERED SPECIES ACT CONSULTATION, PHASE I
Mooring Buoys
List of Requirements
Version: May 3, 2017
Programmatic Endangered Species Act (ESA) Consultations [U.S. Fish and Wildlife Service (USFWS) reference
number 01EWFW00,2015-I-0104, National Marine Fisheries Service (NMFS) reference number WCR-2005-
07506] have been completed for the activities listed below. If you can design your project to meet all or most of the
requirements of the Programmatic Biological Evaluation as summarized on this List below, then the U.S. Army
Corps of Engineers' (Corps) ESA review of your permit application will be expedited and streamlined. The
submittal of this List to the Corps is not required. However, to further expedite your review, you may include a
description of how you meet these requirements in your permit application materials.
Programmatic ESA Requirements
1. Work will be performed within the approved work windows for listed species and
Xforage
fish. The action shall only occur once within the approved work window for
a single and complete project. These work windows are located on the Corps
website at www.nws.usace.army.mil. Select Regulatory Branch, Permit Information,
Permit Guidebook, Chapter X. Work Windows. (Note: Work windows are only
required to meet NMFS programmatic conditions. Work windows are required for
the USFWS programmatic only if the buoy will be installed in or within 328 feet of
documented forage fish spawning habitat, work will only occur during the
appropriate forage fish work window. Otherwise, no work window restriction for
USFWS programmatic.)
X2.
Activity is limited to placement of mooring buoys for single boat, non-
commercial use.
3. Buoy location will be accessed by a small boat or dinghy.
4. Buoy installation will take place as follows:
X
0 One or two SCUBA divers will screw a helical anchor into the substrate.
b. If the substrate is too hard for a helical screw, a 5-gallon bucket filled with cured
concrete will be used.
c. If substrate is too hard for a helical screw and a 5-gallon bucket filled with
concrete is not adequate, a fully cured concrete block or steel anchor up to a
maximum weight of 2.5 tons and maximum size of 4 cubic yards dependent on buoy
size can be used.
—
5. Uncured concrete will not be allowed to come into ontact with surface water.
6. Buoys will be placed at a tidal elevation between ; feet relative to Mean Lower
XLow
Water (MLLW) and -30 feet relative to MLLW or, in freshwater, at a depth of
greater than 15 feet. (Note: Required to meet NMFS programmatic conditions only.
No depth requirement for USFWS programmatic conditions.)
7. The buoy will be 3 feet or less in diameter, made of a Styrofoam ball with plastic
Xcoating
and a steel rod through the center with key holes at the top and bottom: one
for the anchor attachment and one for the boat moorage.
01
Programmatic ESA Requirements
8. The anchor, buoy, and moored vessel will not be located over or within 25 feet of
vegetated shallows (e.g. eelgrass; except where such vegetation is limited to State -
designated noxious weeds). The anchor must be located at least 25 feet plus the
length of the moored structure from vegetated shallows.
9. The anchor, buoy, and moored vessel will not be located over or within 25 feet of
X
spawning habitat for forage fish species. The anchor must be located at least 25 feet
plus the length of the moored structure from spawning habitat,
10. Buoys will not exceed four per acre at any time.
11. Buoy anchors will be installed so that the anchor line does not drag or scour.
12. Flotation will be completely contained to prevent breakup.
13. Moored vessels will not ground out at low water.
GENERAL CONDITIONS (as applicable)
Gl. No new access roads, routes, or trails will be included as part of the proposed
action. a
G2. Any fill material (e.g., sand, gravel, and rock) will be washed and cleaned prior
to being brought to the site.
G3. All fill material will be obtained from a commercial source that is operating in
compliance with the Endangered Species Act.
G4. No stockpiling or staging of material will occur waterward of the Ordinary High
Water Mark (OHWM) or High Tide Line (currently MHHW).
G5. No trenching will occur through any water of the U.S. (i.e., for electrical
cables).
G6. No work will be performed and structures and fill materials will not be placed in
or adjacent to vegetated shallows (e.g. eelgrass; except where such vegetation is
limited to State -designated noxious weeds), wetlands, special aquatic sites, or
suitable forage fish spawning habitat.
G7. Barges will not be used within 25 feet and material will not be placed in or on
vegetated shallows (e.g. eelgrass; except where such vegetation is limited to State -
designated noxious weeds) or other special aquatic sites.
G8. If a barge is used to deliver material, the barge or other structures shall not
ground out on the bottom.
G9. The bottom of any structure, vessel, watercraft grid or watercraft lift will be at
least 1 foot above the level of the substrate during all water levels.
G 10. All equipment that will operate over water or waterward of the OHWM or
High Tide Line will be cleaned of accumulated grease, oil, or mud. All leaks will be
repaired prior to arriving on site. Equipment will be inspected daily for leaks,
accumulations of grease, etc., and any identified problems will be fixed before
operating over water or below the OHWM or High Tide Line.
G 11. No solvents or other chemicals will be used in or over the water during the
construction or operation of the proposed action.
I' NEx' ..? P605, A/W.
"'Mr -
mom
2.
_..__.__ .. 1ft. "'a Surrey
oAbbotsford
M
Sak0r-81109W
National Foi
E
Olympic
National Part �
otymple" t
National Foeestk N
Ter
iuP
Olympia
Q
Go:. gle a
X
n.jr12M6i�
Proposed Mooring Buoy Location:
LAT/LONG: 47.8634,-122.6911
Reference #: NWS-2019-391
Proposed: Install a mooring buoy with a
Adjacent Owners
helical anchor, midline float, and buoy ball at
1) lames Lemmon
a depth of-12-feet MLLW
(996600015)
811 South Point Road, Port
Ludlow, WA 98365
Applicant: Langaker, Stanley
In: Squamish Harbor
Site Location: 833 South
Near: Port Ludlow
Point Road, Port Ludlow,
WA 98365
2) Martin Clark (996600013)
Associated Parcel #:
835 South Point Road, Port
996600014
Ludlow, WA 98365
DATUM: (MLLW)
County: Jefferson
Page 1 of 3
No other mooring structures located with' 1 e (118-foot radius) of the proposed location.
Reference #: NWS-2019-391
Proposed: Install a mooring buoy with a
Adjacent Owners
helical anchor, midline float, and buoy ball at
3) James Lemmon
a depth of -12-feet MLLW
(996600015)
811 South Point Road, Port
Ludlow, WA 98365
Applicant: Langaker, Stanley
In: Squamish Harbor
Site Location: 833 South
Near: Port Ludlow
Point Road, Port Ludlow,
WA 98365
4) Martin Clark (996600013)
Associated Parcel p:
835 South Point Road, Port
996600014
Ludlow, WA 98365
DATUM: (MLLW)
County: Jefferson
Paget of 3
WATER
DEPTH: 12-feet
Al M11W
SWING RADIUS
2n NEC
\ AU14a(,
ANCNOA
�r
SURFACEFLOAT
DISTANCE OFF 101 IOM
`
F/r Midline Float
Embedded Anchor .. _.._....__
Reference #: NWS-2019-391
Proposed: Install a mooring buoy with a helical anchor,
midline float and buoy ball at a depth of -12-feet MLLW
In: Squamish Harbor
Near: Port Ludlow
County: Jefferson
Site Location: 833 South Point Road, Port Ludlow, WA 98365
Associated Parcel #: 996600014
DATUM: (MLLW)
/S
,y8^Inch
diameter
Page 3 of 3