E East Elevation
Scale: 1/4" = V-0"
24'-0"
------------
- Nate-48" standard bracing paneJs-
Provide TO @ 48"oe
i
Edge of roof abv.
40'-0"
31'-5"
7'-5"
-------------------
6/Ox3/0 P oriz.Slider
Painted or vinyl f loot
Provide elect.instant HW
Insulate all concealed piping -
Provide water shut-off & drain
GARAGE -STORAGE-WORKSPACE
39/Ox23/0
---- --------------
Verify lighting and power _
3/Ox3/0
---------------- ----------------
1 1 I I
1 I I I
1 I 1
1 1 I I
--
--------------- ------
12'-6"
Main Floor Plan
Scale: 1/4" = V-0" 960 sf-unfinished area
15'-0"
en' _N1
3/0x3/0
8'-711 V-611
!Overhang Typ.
Exhaust 50cfrn min. ---
to ext.grille w/ backdraft o
control
�3/4 Bth
6
c I v
_--,--------------------- NtaoC s+Y
G�� -
I
of -
Provide power for overhead door
I
>
0
0
., I
0
o
I R3
I rify if low -head track required
_____________ ____________
3/0 u
tin panel -verify I�
2
Alt. door location 1
:: I het 4Rt P�e.1.e�
.bnaer
8'-711
------------------------
Recommend install HD @ main corners
j
Recommend crack control joints @ 10 -14 ft centers
Sloe slab to drain @
overhead door -verify
4" min.conc.slab
w/ 6x6-10/IOWWF reinf.
r
J
,
I
i
12" min.exp.ftg-typ.uno.
2 Required
Verify footing on compacted, native soil
,
Foundation Plan
Scale: 1/4" = 1'-0"
g
Grade
N North Elevation
Scale: 1/4" = V-0"
S South Elevation
Scale: 1/4" = V-0"
12
5 TYP•
TYPJ 3
12
■
If attic insulate and sealed
Provide 462 sq.in.net free vent area
distribruted between eave & gable
GARAGE -STORAGE-WORKSPACE
E
Typical Section
1/4" = V-0"
W Scale:
4'-01'
Exterior Wood Panel
or Interior GWB-2-sides
or
11
Exterior Wood Structural Panel
Interior GWB-1 side
1/2"nominalAPA-rated 24/16 panel
—
sheathingg-applied horiz. or vert
on 2x4 (6) studs @ 16"oc
---
r -�
—
Secure w/ 8d @ 6"oc-edges/12"oc-field
.j
Edge blocking not required.
Interior GWB Panel
1/2" nominal GWB-applied horiz.or vert.
('
on 2x4 (6) studs @ 16"oc
Secure w/ 6d wallbd nails @ 7"oc-edges &
field -or equivalent fasteners.
Edge blocking recommended
I
l
Verify w/ local authority.
I.
Cutaway shown for illustrative E
purposes only E
L
Ij
•�
0
Exterior Panel only -
Recommend extending panel in one piece
to foundation late below 0
W West Elevation
Scale 1/4" = V-0"
GENERAL NOTES
These drawings are abbreviated in content, showing general building set out,
structure, and code compliance, and are intended for design -build projects built
by an experienced, licensed Contractor, who is knowledgeable with local codes,
ordinances and building practices. Based on final product selection, it will be
necessary for the Contractor to provide supplemental details and information.
Additional information is available from Will Langemack Ltd. upon request.
The Contractor shall verify field conditions and dimensions and shall coordinate
final product selection prior to construction or fabrication. Unless otherwise
noted, material call -outs are generic. Installation of these components shall be
coordinated with the various trades and shall be installed according to product
manufaCurers' installoiiorl guides, shop drawings and/or independent testing
reports.
While every attempt has been made to provide a cohesive plan set, clarifications,
modifications, adjustments and/or corrections may be required during the course
of construction. It shall be responsibility of the Contractor to notify
Will Langemack Ltd prior to executing any significant modification to the building,
as such modifications may jeopardize the buildings code compliance and structural {
integrity. T I \
Code Standards:
\�\
Uniform Building [V91.1-3], Plumbing, Mechanical and Fire Codes 1997
Existing Access Easement
\ \
National Electrical Code 2000
Material Structural Standards: [Unless otherwise noted on drawings]
I \ \
I \ \ 10 ft setback
Wood :Sawn Studs - HF-Stud
\��\
2x or 3x Toists/Rafters - HF#2 or btr
4x Beams DF#2 or btr
\� \
Proposed Gorae
\\
Beams/Stringers DF#1 or btr
Posts/Timbers DF#1 or btr
Composite: Glulams 24F-V8 DF/DF
Boise Cascade ER-5512
Trus joist ER-4979
Future House `O
Structural Panels: Sheathing APA Rated 24/16
Subfloor APA Rated 2-4-1
Sturd-1-floor or
Underlayment APA Rated Underlayment
\�\
DrainfieldArea
Concrete: Concrete Mix f'c=2500 psi min. @ 28 days
Reinforcing Steel fs=40000 psi min [Grade 40] A-615-17
Welded Wire Mat fs=40000 psi min A-185
Water & Aggregate Clean
Plate
Moondance Drive
Steel: Shapes, Angles & Plates A-36
Round Pipe Fy-36
Schematic
Site Plan
Tubing Fy46k
Bolts A-307 f�J
Wood Connectors & Accessories -Simpson Strong -tie 0
100 ft
General Construction and Installation [Unless otherwise noted on drawings]
iv
1- All foundation worksholl conform to the prescriptive provisions of UBC 1906.
2- All wood construction shall conform to UBC Chapter 23 and specifically the
prescriptive provisions of UBC 2320-Conventional Light -Frame Construction.
3- Fastening of various building components shall conform to UBC Table
23-II-8-1 Nailing Schedule.
4- Utilize manufactured and tested components wherever possible. Component
installation shall eoeform to manufacturer's installation guides.
;lab
5- Specially, fabricated components [eg.trusses and specially steel fabrications]
may required special engineering and certification. Verify with local code
authority for specific submittal requirements prior to fabrication/installation.
6- Any steel welding welding shall be performed by a AWI certified welder.
7- All work shall be installed plumb and level. Use only new, undamaged materials.
8- All exterior surfaces exposed to weather shall be finished with a weather
resistant product or finish. Seal and insulate all exterior surfaces if building
is to be heated.
9- Electrical, plumbing and HVAC systems are to be design -built by qualified
sub -contractors. Only general qualifying criteria are noted on this plan.
2--Bn
Exterior & Interior Wood Structural Panel
Suppporting Roof only
= — 1/2"nominalAPA-rated 24/16 panel
sheathing -applied horiz, or vert.
on 2x4 (6) studs @ 16"oc [ 1 side]
Secure w/ 8d @ 6"oc-edges/ 12"oc-field
Edge blocking is required.
Supporting Fir/Roof
1/2"nominal APA-rate 24/16 panel
!• sheathing -applied horiz.or vert.
@ 2x4 (6) studs @ 16"oc [2 sides]
Secure w/ 8d @ 4"oc-edges/12"oc-field
Edge blocking is required
Provide dbl.studs @ vertical edges of panel
Secure dbl.studs w/ 16d @ 12"oc
.I Cutaway shown for illustrative purposes only
Secure to foundation plate and sole plate..,
I•i
;•I
Secure sole plate to joist, rim or plate
t
w/ 3-16d @ 16"oc
Secure sole plate to joist, rim or plate
w/ 3-16d @ 16"oc
Recommend extending panel in one piece
to foundation plate below. 4" concrete slab
-----
:i-
Secure to both the fnd/sole plate. ✓4/6x6-10/10 WWF
Sub -floor shown
Rim Base Plate
Install Simpson PHD2 Hold-down @each edge footing @ perimet
on 2 nom. clean son
on Joist on
secured by standard AS
I
I
Secure to AS below w/ 5/8" H threaded rod &
Simpson CN coupler nut, an 6 mil black PVC
See Standard Wall detail
Alt. Simpson HD2A for Bracing Roof on 4" nom.gravel ba;
II
Simpson HD5A for Bracing Flr/Roof
Provide dbl.joist, blocking
prarsqueandhsblocks under
II
r
',
must bell Alternate supported byrcontinuousPanelfoundation / L #4@ftg bottom
✓✓✓ w/1-#4 @top
Install Simpson SSTB16 AS ( 2 places) 3"dr to earth typ.
w/ 12"min.embedment
_...__• _.
-
--_L�l
Verify ali nment w/ HD ab
1 _Standard Wall Bracing Panel
1 Scale: 1/2" = 1'-0" Conforms to UBC 232.11.3
:Iove
Verify #4 cont.rnf @ top/fnd.wall
Install additional AS for Bracing Flr/Roof
�1 Alternate Bracing Panel
1 Scale: 1/2" = 1'-0" Conforms to UBC 232.11.4
Comppositon shingles
on 15# building felt
on 5/8" APA rated ply sheathing
Manufactured scissor trusses @ 24"oc
2x4 blocking
Install Simpson H-7 tie -down (P-48"6c,
��y firu9S
Coated metal downspouts
on 5/4x8 cedar fascia
4x10 DF-2 Header Typical UNO
Vinyl -framed insulating glass windows
Verify interior/exterior casework
Tape window flange & flash
APA 303-ply siding [T-111]
on buiding paper or Tyvek
on 2x4 Studs @ 16"oc
2x4 PT -plate
w/ 5/8"dia.x10"A.B.@ 48"oc [2 min]
w/ 2x2x3/16 stl.plate washer
Install A.B.@ center PL and within 6"of PL ends
Provide 7"min.embeddrnent uno.
Field verify that base of footing
bears on compact undisturbed earth
UBC Classification
Occupancy Group: U [Accessory to Residence]less than 1000 sf
Constrution Type: V-N
Proposed Area: 960 sf
Heating Type, Unheated currently
Loading Criteria
All structural elements desi designed o e n for these Ions shall use
9 P
the following assumed loading criteria:
Vertical Loads
Roof: 17psf-DL 25psf-LL 42psf-TL
Floors & Decks: 15psf-OL 40psf-LL 55psf-TL
Exterior Balcony 15psf-DL 60psf-LL 55psf-TL
Primary Exit: 15psf-DL 100psf-LL 115psf-TL
Stairs: 15psf-DL 100psf-LL 115psf-TL
or 300 Ibs.concentrated LL
Private Garage: 25psf-OL 50psf-LL 75psf-TL
or 2000 Ibs.concentrated LL
Guardrails: 20 plf lateral load @ top rail
or 25 psf lateral load of total rail system
Handrails: 200 lbs. concentrate LL
Lateral Loads
Wind Zone: 80 mph less than 40 feet
Seismic Zone: 3
Soil Loads Assume Soil Profile SO
1500 psf nominal bearing capacity
150 psf nominal lateral bearing capacity
Use 40 pcf equivalent hydrostatic pressure
for structure retaining earth
The above loads shall evaluated according to the Basic Load
Combinations for Allowable Stress Design, UBC 1612.3.1,
unless otherwise noted.
This plan may indicate a schematic truss layout for design by
others; load paths may require reevaluation if final truss
layout has been changed. Verify prior to truss fabrication.
Structural Connections
Refer to Nailing Schedule UBC 23-II-8-1 for default attachment
unless modified by note or schedule.
All anchor bolts [AB] shall be J-style, complete with matching
nut and 2"x2"x3/16" plate washer. Size as noted on plans.
All machine bolts [MB] shall be complete with matching nut
and washers: Size as noted on plans
All metal light -framing connectors shall be Simpson Strong -Tie
or equivalent manufactured/tested component. Unless otherwise
noted on plans use the following basic styles, sized to suit the
wood element being joined. Secure per mfr.to develop the full
rated listed capacity. [Plan abbreviations are noted.]
Joists/Rafters Hanger[ JH ] LUP or U Hanger
Light Beam Hanger [ BH ] HU Hanger
Heavy Beams Hanger [ HBH ] LEG Hanger
Post Base [ PS ] EPB or CB
Column Cap [CC] BC, or CC
Hold-down [ HD ] HD2A or PHD2
Framing clip [ FC ] A-35
Tie -Down [ TO ] H-3/Rafter H-7/Truss
Coil Strap [ CS ] C520
All components exposed to weather shall be galvanized or have
an approved coating for the use intended.
Sheathing and Structural Panels
Secure all roof and wall sheathing [UNO] as follows:
8d @ 6"oc @ all edges and 12"oc @ field
Block panel edges where noted on plan
Freeman -Hui
Garage
by
Olympic Ridge Construction
Job.No. 2000.5
Date 14 April 2000 Revision
�11 Langemack"