Loading...
HomeMy WebLinkAboutBLD2018-00185 - 02 SOLAR DESIGNDEPARf,ENT OF COMMUNITY DEVTPMENT 521 Sheridan Street, Port Townsend, WA 98358 Telr 360.379.4450 | Fax: 360.379.4451 Web: www.co. iefferson.wa. us/communitvdevelooment E-mail: dcd@co.iefferson.wa.us EXPEDITED PERMITTING CHECKLIST FOR RESIDENTIAL P ROOFTOP MOUNTED AIC SYSTEMS: @ eroject lnformation A, Determine if your proiect needs a building permit (chec all that apply): tf you answered yes to all of the above questions, an over-the-counter permit is authorized. @ SuUmit this Checktist and Mechanical Permit Application and Site Plan to: I attest that all information in this checklist is accu to the best of my knowledge. Project Applicant: Site Owner Name:lr€ 1 Project Address PV system description Yes No L. PV system is designed and proposed for a structure previously built to code.tr tr 2. PV system is designed for rooftop of a building in general compliance with applicable codes.A tr 3. Mounting system is engineered and designed for PV.{n 4. Rooftop is made from lightweight material such as shingles..K tr 5. PV system has been pre-approved by electrical permitting agency.K tr 6. To address uplift, panels are mounted no higher than 18" above the surface of the roofing to which they are affixed. Except for flat roofs, no portion of the system may exceed the highest point of the roof. .a tr 7. Total dead load of panels, supports, mountings, raceways and all other appurtenances weigh no more than one of the following. lf YES, indicate which: n No more than three and one-half (3.5) pounds per square foot (PSF) n Frameless panels on at least 3h2 pilch roof weighing no more than four and one-half (4.5) PSF n Frameless panels on at least 5lt2 pitch roof weighing no more than five (5.0) PSF Z tr 8. Supports for solar panels are installed to spread the dead load across as many roof-framing members as needed to ensure that at no point are loads in excess of fifty (50) pounds are created. ,Y 9. Attachment to the roof is specified by the mounting system manufacturer.E.tr 10. Method and type of weatherproofing roof penetrations is provided K tr 11. Home is code compliant to setbacks and height, or code allows expansion of nonconformity for solar panels. g 12. Panels are mounted no higher than the roof ridge or apex of roof (applies only to pitched roofs)K n Applicant Signature 4-fl 46Date Applicant Name (Please Print): 1o, T €ta_ O // ,l^ $' f<-a{ = tr tr 4t8t2014 Off Grid 5.4kW Residential Solar Power System I altE BASE COMPONENTS OF THIS OFF GRID SYSTEM: The solar panels and the pre-wired inverter/charge controller system and components are included in the base kit. Battery bank and Mounting solutions are options that you can add on. oOff-Grid 5.4kW Solar Power System lncludes: Part Number Item Description Quantity SOW3OOSW3OOMWOB SolarWorld 300 Watt Solar Panel 18 PVCH4-5OFT 50' H4 Connector Cable #10 AWG 2 PVCH4-1OOFT 100' H4 Connector Cable #10 AWG 4 GENT4KEY Disconnect Key for Solar Panel Connector Cables 1 frI-rt TIl'r[ GENSR.2HOLES-LN l12 Strain Relief, 2 Round Holes/Locknut A)qto 4L 6 GENSR-1HOLE-LN 112" Strain Relief, 1 Round Holes/Locknut 1 t,ocz{ IVIDMNPV6 Midnite Solar MNPVO Combiner Box -tr,o C, 1 GENBRKDIN-20 20 Amp Din Rail Mount Breaker 6 -!v @ t\,eDF 'U2 418t2018 MIDIUNXWP554821 Off Grid 5.4kW Residential Solar Power System I altE Pre-Wired Power Panel - Schneider Conext XW+ 5548 1 1 O MPPT Ch and (2) Midnite Classic Controllerse o oa,f, @ t\,ED @ (- m.tI "tl mn6oAoo 2 -l oo Solar Surge Protection Device - 300V DC 2 ALTBC-4IO.12ORB altE Battery to lnverter Cables , 410 10',Pair r 1 212 418t2018 Off Grid 5.4kW Residential Solar Power System I altE This item is a package made up of the following components. Please call to speak to a sales representative to leam about other options which may be available. 18 x SolarWorld 300 Watt Solar Panel, Sunmodule SW300 Mono, Black Frame 2 x 50' H4 Connector Cable #10 AWG 4 x 100' H4 Connector Cable #10 AWG 1 x T4 Disconnect Key for MC4/H4IT4 Connec 1 x Midnite Solar MNPV6 Combiner Box 2 x Midnite Solar Surge Protection Device 300VDC and 1201240 VAC 6 x 1/2 lnch 2 Hole Strain Relief with Lock Nut 1 x 1 12 lnch Single Hole Strain Relief with Lock Nut 6 x Midnite Solar 20 Amp Din Rail Mount Breaker 1 x Midnite Solar MNXW554B-CL150(2) Pre-Wired System 1 x Battery to lnverter Cables, 4/0 AWG 1OFt (120"), Red/Black Pair o o ilt.It TI m:,6ozooCz {ooo -t,4 a ,\J EDs 111 Sunmodule/Plus sw 290-300 M0N0 TUV Power controlled: Lowest measuring tolerance in industry Every component is tested to meet 3 times IEC requirements Designed to withstand heavy accumulations of snow and ice Sunmodule Plus: Positive performance tolerance 25-year linear performance warranty and lO-year product warranty Class with anti-reflective coating Worl4tlass quality Fully-automated production lines and seamless monitoring of the process and material ensure the quality that the company sets as its benchmark for its sites worldwide. ,4NE=f tu.llfd. tE( 5!tl5 "@:. tldnt rr.d r.rBts.., lE( @06!-2.6t uL 1703 SolarWorld Plus-Sorting Plus-Sorting guarantees highest system efficiency. solarworld only delivers modules that have greater than or equal to the nameplate rated power. 25yar linear ptrfomance guanntee and extenrion of product wanan$ to l0 year Solarworld guarantees a maximum performance digression of o.7% p.a. in the course of 25years,a significant added value compared tothe two-phase warranties common i n the i nd ustry, a lon g with ou r i nd u str@t(ltftfg{n0$ ftffffgigJr,,l (((!)ffiHom lnnwatl,onxclr GtlaI c!tfiraD /r"-\'- Ef, 'in accordance with the applicable www.solarworld.com/warrantlr solarworld.com A TUVRIEhLd il a -o/+tWp Solarworld Limited Warranty at purchase. Ittttll Sot.anWonlo \-/ REATVALUE T ffi 8l0e I I uav i F- I{ - Sunmodule/Plus sw 290-300 M0N0 PEnFORMAilCE UI{DER STANDAXD TEST COf{DmoilS (STCr oco NOSUsJJ3r 5W 290 5W 295 sw 300 i oximum powet P,290 Wp 295 Wp 300 Wp Open circuit voltage 8t 39.9 v 40.0 V 40.1 V Maximum power point voltage 3r.4 V 11.5 V 31.6 V Short circuit current 9.97 A 10.'10 A lo.2l A Maximum powet point cutrent 9.33 A 9.45 A 9.57 A Module efficiency q-'17.10%17.59%17.89% PERToRMANCE AT800 WMr, t{ocT, Am 1.5 'sTC: lOOOw/mr, 25 'C, AM 1.5 5W 290 5W 295 sw 300 Moximum powet D 2171Wp 22O.swp 222.7 W? Open chcuit voltage t6.6 V )6.7 V 36.8 V Max im u m power point volta g e 28.8 V 28.9 V 29.0 V Short circuit cunent t,.8.05 A 8.17 A 8.19 A Moximum power point cunent l*7.54 A 7.64 A 7.71A Minor reductiof, in efficiency under Partial load conditions at 25 'C: at 2oo Wr#, tOO% of the STC efficiency (IOOO Wm.) is achieved. r0ooW/IIP COMPONENT MATERIATS 8OOW/5r Cells pcr module 60 Frcnt Low-iron tempered glass with ARc (EN l2ls0) 3 I r = 50oW/m,Cell type Monocrystalline 5-busbar Frume Black anodized aluminum 4OOW/mr Cell dimensions 6.17 in x 6.17 in Weight le.7 lbs (18.0 kg)(156.75 x 156.75 mm) THERMAT CHARAOIRIST]CS ADDITIO]IIAT DATA NOCf 46'C Powertottlng -0 Wp/+s wp nodule vothg. lvl TCl,,O.O4% /'C t-Box tP65 37.8 (e6r) fcv*-0.3o% /'c PV wire per UL47O3 with H4/UTX connectorsTCPry Connectot -o.41% /'C Operutingtemp -uloto+85"C Modulefircpcfotmonce (U11703)Typel PARAIT'ETERS FOR OPIIMAT sYsTEM II{TEGRATION Maximum syrtem voltage SC ll / NEC 1000 v Mqximum rcYe6e (umnt 25A Number of bypass diodes o o F Design loods'Two rail system 113 psfdownward, 64 psf upward Design loads'fhree rail syrtem 178 psfdownward ,64 psf upward Design loods'Edge mounting 178 psf downward,4l psf upward 'Please refer tothe Sunmodule installation instructionsfor the detailr associated with these load cases. I o..r 0D I . Compatible with both 'Top-Doln" and'Eottom' mounting methods . * Grounding l-ocations, -4 locations alongthe length ofthe module in the extended flange. 11.32 r"I(287s0) ,9.4 0001) r.30 (33) All units provided are imperial. Sl units provided in parentheses. Solarworld AG reseruesthe rightto make specificetaon changes without noti€e. r.E(29) 5W-0'r-7s05u5 l6t2rl 4r+ o 0.35 oi g 0.26 O o.rs ;'f l-' ltttrll SomnWonlo \-/ REATVALUE 200W/m, +.zo T (1o6.6s)l ,.r, I(t8o.8, I T 3 Drill holes for lightnlng arrestors, use SS bolts with lock washer Cut finger bus bar in half o o PV1+PV2+ a a o a a a 6 o o 6 aa Combiner box, installed near PV array PV wire extension cables, cut in two SPD Customer wire in conduit To PV1 +To PV- Page To GND To PV2+ IIII -r,E e t\,c,s fi6 Bare copper to grounding rod oo 2{ ooD 18 panel Off-grid solaraltstoreFor reference only, Refer to manuals.3t28t2017 Page 1 of 4 o o Customer lnstalled DC wiring scP *::tiI @@ 3=;gEEIT XW+ sEltO umnY umnmw x&M From PV- From PV1+ From PV2+ From PV GND r '@' cltfc 0 T e I iwl- srElU]? 38ffi" ire^ 9islEis:ffi PV+ 1 Al2 + w $ @ 250 ON T OFF 4/O copper cable + zl8V Battery Bank APR I g 20t8 .IfrFFERSON COUNTY DCD 18 pane! Offgrid solar-tl astore For reference only. Refer to manuals.312812017 Page 2 of 4 BT5 BTS o Customer lnstalled AC Wiring o =tr flm BATTERY BATTERv ftr fo "POSITIVE NEGATIVE @@ zzz c$c3 53s58 ->rr>-->r Schneider XW+ o o o o o o o o o + -l.l.l -lcl.l !ffi:ffi Et+t Et+t,Etr 'Etr AllWiringto N coN ECTED SYSTEMS lnput from Secondary AC source APn ,*orr, *rror'f,fff;f;fiO" WIRE WHEI{ USED ON 6RID I I 20t8 Loads oco !,IJ e5E3E r.rF<l>6_LzE-E .E o, To Ground rod, unless AC system has a ground rod in the Main utilfi Panel already. B l$l lD [rlclt r'llr ltlt r lle t1 OUT IN L1 tN1 L1 tN2 18 panel Offgrid solar For reference only. Refer to manuals.312812017 Page 3 of 4 AC Out to Critical 1, store MidNite lnstalled AC & DC wiring AIIAC wiring inside by MidNlte Solar to be fiG wire unless marked. o o l,a 6 t\,cao o o Schnelder XW+ t_ str 3tr FfaEiltr-BATTERY BATTERY POSITIVE z22eqPS ESeEs{:'r0 tozdzE>FT >FF>FF N P FN cussrc '@250 ON T IOFF L1 rN1 cBstc -"gt PV+ 1 L1 tN2 #2 BANERY PLUS BUS NOTE: REMOVE THIS BOND WIRE WHEN USED ON 6RID CONNECTED 5PD SPD uufifl,fl]:r 18 panel Off-grid s For reference only Refer to manuals.3128t2017 Page 4 ot 4 o CO ts z B F?z L1 OUT PV+ 2 # o ," tlt .1".*.\ \-*SV Iti-FuellOHtER,.Power Systems rHFngpg66,Gas og NAIIONATI,Y TICISIE'TO The Kohlef Advantage o High Quality Power Kohler home generators provide advanced voltage and frequency regulation along with ultraJow levels of harmonic distortion for excellent generator power quality to protect your valuable electronics. o Extraordinary Reliability Kohler is known for extraordinary reliability and performance and backs that up with a S-year or 2O0O hour limited wananty. o Perfect for Tight Lot Llnes Can be placed as close as 18 inches from your home or small business, providing installation flexibility even on smaller lots. (Only applies to engine specffication numbers GM88347-GA7 or higher. Check state and local codes for minimum required distance from a structure.) o Powerltrl Performance Exc'lusive Powerboost* technology provides excellent starting power. The Kohler I kW generator can easily start and run a 4 ton air conditioner with up to 4.5 kW preload.* r Enclosure Bold new Kohler design in steel, dipped in e-coat for extra conosion protection and painted with a durable powder coat finish. o Quiet Operation Kohler home generators provide quiet, neighborhood- friendly perbrmance. Standard Features o RDC2 Contloller o One digital confoller manages both Ute gererator set and transfer switch functions (with optional Model RXT transfer switch). o Designed for today's rnost sophisticated electronics.o Electronic speed control responds quickly to varying household demand. o Digital voltage regulation protects your sensitive electronics from harmonic distortinn and unstable power quahty. o Tvrro-line, backlit LCD disgay witr adiustable contrast is easy to read, even in direct sunl(7ht or low light. o OnCueo Plus Generator Management System for remote monitoring is inchded with wery generator. o Kohler Engine Features o Kohler engine with efficient OHV designo Powerful, reliable air-cooled performance o Simple field conversion between ndlral gas and LPG fuels while maintaining emission ceffication o Designed for Easy lnstalladon o Steel base o Hinged, locking roof o Fuel and electrical @nnections through the enclosure wall eliminate the need for stub.ups through the bottom o Accepts natural gas fuel pressure as lo,v as 3.5 incheso Load connection terminal blodr dlorvs easy field wiringo Designed for outdoor installation only o Approved for stationary standby applications in locations served by a reliable utility source o Meets 181 mph wind rating o Certifications o Meets emission regulations for U.S. Environmental Protection ASency (EPA) .!0 CFR 60 stationary source standards with both LPG and natural gas- Note: CARB does not regulate emergency standby generators outputting less than 5O HP. Only the EPA standards apply. o ULa2o0listed (60 Hz modet) o Accepted by the Massachusetts Board of Regisfiation of Plumbers and Gas Fitters. 9001 EITE Pa\./tR Sf,Tl,r.,s Generator Rati n9s Model Phasc Hz Altemetor Strrdby Badngs NaturalGas LPG kWkVA Amps lil/kvA Amps GUIDEUNESFoRDERATING:lLfirUD€:Deraocxpersoomltomfr.ldaarihaborelsBm(sooit.). rcrt*neiiAeoizp'*,tpsss;Ctib"nterpserrair,Bseabo,.t6"c(so"q. ContEct you, locat Kol$or Co. gdlorats dsfih.ior ior 6raibt{ty. mquirerHE. Ga-252 (8RESV) 5/17a a t, ,-..e-- Alternator Specifications o Alternator Specifications Alternator Features o Specafications PowerBoost" Generator 1-Phase o Compliance with NEMA, IEEE, and ANSI standards for temperafure rise o Setf-ventilated and dripproof construction o Windings are vacuum-impregnated with epory vamish for dependability and long life. o Superior voltage waveform and minimum harmonic distortion from skewed afternator construction o Digital voltage regulator with =1 .0% no-load to full-load RMS regulation . Rotating-field alternator with siatic exciter for excellefit load response o Total harmonic distortion (l'HD) from no load to full load with a linear load is less than 5% APR t g 2018 Manufacturer Ouput reconnectable Type Leads, quantity Vottage regulator lnsulation: Material Temperature rise Bearing: quantity, type Goupling Amortisseur wirdings Vottage regulation, no-load to full- load RMS One-step load acceptance Peak motor starting kVA: 24ov,zFg (60 Hz) Engine Kohler 1201240 2-Pole, Rotating Field 4 Digital NEMA MG1.1.66 Class H Class H 1, Sealed Ball Direct Full + 1.Oo/" 10O% of Rating (35% dip for voftages below) 16.8 I I a Ap p I i catt HrPf,,? r ectrica r . r EFF ERsoN co uN Ty DcD Ii\, 'l Engine Specifications Engine Electrical System Manufacturer Engine: model, type Cylinders Displacement, cm3 (cu. in.) Bore and stroke, mm (in.) Compression ratio Main bearings: quantity, type Rated RPM 60 Hz Max. engine power at rated rpm, kW (HP) LPG,6O HZ Natural gas,6ig 1-12 Cylinder head nraterial Valve material Piston type and material Crankshaft material Govemor: type Frequency regulation, no load to full load Frequenry reguhtion, steady state Air cleaner type Exhaust Kohler sv620 Single ss7 (36.4) 94 x 86 (3.7 x 3.,14) 8.5:1 2, Parent Material 3600 11 (14.8) 8.5 (11.4) Aluminum Steel Aluminum Alloy Heat Treated, Ductile lron Electronic lsochronous *1.OV" Dry lgnition system Starter motor rated voltage (DC) Battery (purciased separately) : Ground Volts (DC) Battery quantity Recommended cold oanking arnps: (CCA) rating for -18'C (0"F) Group size Lubrication Elec*ronic, Capacitive Disctnrge 12 Negative 12 500 51 Lubricating System Type Oil capacity (with filteQ, L (qt.) * Oil filter: quantity, type * Oil capacity for a new dry engine. Fuel Pipe Size Full Pressure 1.s (1.6) 1, Cartridge tlnlmum Gas Plpe Stse Recommendatlon, ln. NPT Exhaust System Pipe l$ngth, m (ft) l{atural Gas 99,200 Btu/hr. LPG 160,800 Btu/hr. Exhaust temperature exiting the enclosure at rated kW, dry, 'C ('D 1 90 (374) 8 (2s) 15 (50) 30 (100) 46 (150) 61 (20o) 3l4in. 314 in. 1 in. 1 in. 'l 114in. 112in. 3l+in. 3l4in. 1 in. 1 in. G4-252 (8RESV) 5/17a i! .'-- t' 0.87-2.7 (3.s-11) 1.7-2.717-111 Fuel Composltion Umits *Nat Gas LPG Methane, % by volume (minimum) 90 min. Ethane, % by volume (maximum) 4.0 max. Propane, % by volume 1.0 max. 85 mln. Propene, % by volume (maximum) 0.1 max. 5.0 mar C4 and higher, % by volume 0.3 max 2.5 max. Sulfur, ppm mass (maximum) 25 max. Lower heatino value. MJ/ms (Bty'ft5), (minimum) 3i,.2 (B9o) u.2 12260lr Contact your local distributor for sultability and rating derates based on fuel compositkrns outside th€so limits. Operation Requirements Fuel Gonsumption Fuel Uodel TyPe % Load Fuel Consump,tion, m3/hr. 1cfir; SRESV 3.e (136) 2.7 (e5) 2.0 (69) l.s (53) 1.1 (3e) o RDC2 Controller @ f.:- "G---B The RDC2 controller provides integrated control for the generator set, Kohlero Model RXT transfer switch, programmable interface module (PlM), and load management device. The RDC2 cpntroller's 2-line LCD scyeen disflays status messages and system settings that are dear and easy to read, even in direct sunlight or low light. RDC2 Controller Features o Membrane keypad " OFF, AUTO, and RUN pushbr.rttons o Select and anow buttons for access to system configuration and adjustrnent menus o LED indicators tor OFF, AUTO, and RUN modes o LED indicalors lor utility power and generator set source availability and ATS position (Model HXT transfer switch required) o LCD screen o Two lines x 16 characters per line contast for excellent o Fuel Requirements Fuel Slstom Fuel types Fuel supply inlet Fuel supply pressure, kPa (in. H2O): Natural gas LP Natural Gas or LPG 1/2 NPT Natural Gas 100 75 50 25 Exercise LPG 1.7 1.3 1.O .75 .38 (5s) (45) (36) t26) (14) '100 75 50 25 o Nominal fud rating: Natural gas: 37 MJm3 (1000 Btulft.3)LPG: 93 MJ/rn3 (2500 8uft.3) LPG conversion factors: 8.58 ft.3 = 1 lb. o.sgsm3=tkg 36.39ft.3 = 1 gal. o Scrolling system status o Generator set status o Vottage and frequency o Engine temperature o Oil pressure APR t g 2018 o Battery vottage o Engine runtime rrours .iEFFERSON COUNTYDCOo Dde and time dbplays o Smart engine cooldsrvn senses engine temperature . Dlgital isochronous governor to maintain steady-state speed at all loads o Digital voltage regulation: + 1.A% RMS no-load to tull-load o Automatic start with programmed cranking rycleo Prograrnmable exerciser can be set to start automatically on any ftrture day and time, and run every week or every two weeks o Exercise modes o Unloaded weekly exercise with complete system diagnostics o Unloaded full-speed exercise o Loaded tull-spesd exercise (Model RXT ATS required) . Front-access mini USB connector for SiteTech" or USB LXility connection o lntegral Ethernet connecitor for Kohlero OnCueo Plus o Built-in 2.5 amp battery charger . Remote two-wire starustop capability for ofional connection of Model RDT transfer switches See additional oortrollerfeatures on the next page. Exercise @ @ @ EI G4-2s2 (8RESV) g17a with visibility Sound Data Model SRESV I point logarithmic average sound leveb are 66 dB(A) during weekly engine exercise andTzdB(A) during fulFspeed generator diagnostics and normal operation. For comparison to competitor ratings, the lowost point sound levels are 63 dB(A) and 68 dB(A) respectively.* All sound levels are measured at 7 meters with no load. r Lolest of 8 pc$nts measured around the geflerator. Sound l€t/ds at ofier potfits around ganerator may vary depending on instdHion parameters. h*g. ,aofllF.rs 6o.oHzl @@tr o o KOHLER CO., Kohler, Wisc,onsin 53044 USA Phone 920-4574441, FaD< 920-459-1 erc For the nearest sales and service outlet in the US and Canada, phone .l-800-544-2444 KOHLERPower.com Kohler Power Systems Asia Pacifi c Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264,4/.22, Fax (6$ 6264-6455 Additional RDC2 Controller Features . Diagnostic messages o Displays diagnostic messages for the engine, generator, Model RXT transfer switch, programmable interface module (PlM), and load management o Over 70 diagnostic messages can be displayed o Maintenancereminders . System settings o System voltage, frequency, and phase o Vottage adjustment o Measurement system, English or metric o ATS status (Model RXT ATS required) o Source availability o ATS position (normal/utility or emergency/generator) o Source vottage and tequency o ATS control (Model RXT ATS required) o Source voltage and frequency settingso Engine start time delay o Transfer time delays o Voltage calibration o Fixed pickup and dropout settings o Programmable lnterface Module (PlM) status displays o lnput status (activefinactive) o OuFut status (active/inactive) o Load control menus Generator Set Standard Features . Battery cables o Critical silencer . EPA ceffied fuel system o Field-connection terminal block o Fuel solenoid valve and secondary regulator . Une circuit breaker: 40 Amps o Multi-fuel system, LPGlnatural gas, field-convertible o Oil drain e)dension with shutoff valve . OnCueo Plus Generator Management System o RDC2 generator seUATS controller . Rodent-resistantconstruction o Sound enclosure with sound-deadening, flame-retardant foam per UL94, class HF-1 . s-year limited wananty Available Accessories* Approvals and Listings I CSAApproval Concrete Mounting Pads I Concrete mounting pad, 3 in. thick I Concrete mounting pad, 4 in. thick (recommended for storm-prone areas) Available Accessories, Contlnued Controller Access(raes fl Programmable lnterface Module (PlM) (provides 2 digital inputs and 6 relay outputs) I Load shed kit I Power relay modules (use up to 4 modules lor each load management device) Electrical System I Battery Fuel System I Flexible tuel line Maintenance I Maintenance kit Literature I General maintenance literature kit I Overhaulliterature kit JEFFERSON COUNIY DCDI Production literature kit Starting Aids I Carburetor heater, 120 VAC (recommended for reliable starting at temperatures below 0'C [32"F ]) Kohlero Automatic Transfer Switch I Model RXT, see specification sheet Gl1-121 I Model RDT, see specification sheet G11-98 I Model RXT with combined interfiace/load management board [] Other Kohlero ATS illscellaneous Accessories tr tr * Accessories are available through Kohler authorized distributors and dealers. Generator Set Dimensions and Weights Overall Generator Size, L x W x H: 777 x712 x 824 mm (30.6 x 28 x 32.4 in.) Shipping Weight: SRESV 170 kg (375 lb.) L r- H _l NOTE: DimsEions ae pwired for refurere orty Jd srndd nd be used fur daming iE-ldla- tion. Contact your local distibutor lc mue d€dailed intomation. @ 2015 and 2017 by G+52 (8RESV) 5/17a DISTRIBUTED BY APR I g 20t8