Loading...
HomeMy WebLinkAboutBLD2015-00008 - PROPOSALr I- KNIGHT FIRE PROTECTION,INC. 44 9702 LATHROP INDUSTRIAL DRIVE SW t , �4 OLYMPIA,WA 98512-9188 !,,ice (360)786-8606 iFAX 786-8722 II LICENSE NO. KNIGHFP044LK ON GUARD 24 HOURS A DAY" Submittal Brochure Jefferson Transit Authority Maintenance, Operations, and Administration Center Index • Pipe • Fittings/Couplings • Sprinklers & Accessories • Valves • Electrical/Fire Alarm Components • Pipe Hangers • Seismic Bracing Component JAN - 7 2015 li ii C 101IIy,0EvELOPPIENr "QUALITY IS REMEMBERED... LONG AFTER PRICE IS FORGOTTEN!" The Eddy Pipe Family Bull Moose Tube Company's "Eddy Pipe" brand sprinkler pipe is produced to meet sprinkler pipe standards & applications. Here are just a few advantages of Eddy Pipe: • All pipe products are UL Listed (for U.S. and Canada), • Available in specific cut to order lengths from and have been Approved by Factory Mutual. regular mill rollings. • Excellent Production & coating capabilities, tighter • More popular sizes roll every two weeks. tolerances, and our unique steel properties make • Floor stock available in various lengths. our pipe excellent for roll grooving, welding, • Available with coating or bare. threading, and plain end fittings. • Ultra Eddy, Eddy Flow, Eddylite, and Eddythread • All products are dual certified to ASTM A-135 and 40 offer cost savings along with superior A-795. hydraulics without compromising service life. **,,, • Schedule 10 and Schedule 40: FM Approved and UL Listed sprinkler pipe • Eddy Flow: Cost effective replacement for Schedule 10 • Eddylite: Lightwall threadable with standard outside diameter • Eddythread 40: Lightwall threadable Schedule 40 replacement with Corrosion Resistance Ratio of 1.0 • Ultra Eddy: Lightwall roll groovable pipe Chesterfield, MO 63D17 contact your salesperson today at C (l� us B A st r r moosE fi r, (800)325-4467 (800)325-4467 or(636)537-2600 ° -- - FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 ALVA�company e-mailsales @bullmoosetube.com APPROVED All information contained herein is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incuwng obligation. 05/08 "BMT - Eddy Pipe" Sizes Available NPS (in) 1 1 1/4 1 1/2 I 2 21/2 3 4 O.D. (in) 1.315 1.660 1.900 2.375 I.D.(in) 1.201 1.546 1.786 2.261 Ultra Eddy Empty Weight(Ibs/ft) 0.868 1.107 1.274 1.604 Water-Filled Weight(Ibs/ft) 1.359 1.920 2.360 3.344 C.R.R. 2.17 1.40 1.11 1.00 O.D. (in) 1.660 1.900 2.375 2.875 3.500 4.500 I.D.(in) 1.530 1.728 2.203 2705 3.334 4.310 >Eddy Flow Empty Weight(Ibslft) 1.222 1.844 2.330 2.809 3.361 4.968 Water-Filled Weight(lbs/ft) 2.019 2.860 3.982 5.299 7.144 11.290 C.R.R. 1.98 3.44 2.78 1.66 1.00 1.00 O.D. (in) _ 1.315 1.660 1.900 2.375 2.875 3.500 4.500 I.D. (in) 1.097 1.442 1.682 2.157 2.635 3.260 4.260 Schedule 10 Empty Weight(Ibs/ft) 1.410 1.810 2.090 2.640 3.530 4.340 5.620 Water-Filled Weight(Ibs/ft) 1.820 2.518 3.053 4.223 5.893 7.957 11.796 C.R.R. 15.27 9.91 7.76 6.27 4.92 3.54 2.50 O.D. (in) 1.315 1.660 1.900 2375 I.D. (in) 1.137 1.482 1.712 2.177 Eddylite Empty Weight(Ibs/ft) 1.260 1.617 1.967 2.617 Water-Filled Weight(Ibs/ft) 1.700 2.364 2.965 4.230 C.R.R. 0.13 0.08 0.12 0.16 O.D. (in) 1.295 1.650 1.900 2.375 I.D.(in) 1.083 1.418 1.654 2123 Eddythread Empty Weight(Ibs/ft) 1.461 2.070 2.547 3.308 40 Water-Filled Weight(Ibs/ft) 1.860 2.754 3.478 4.842 C.R.R. 1.00 1.00 1.00 1.00 O.D. (in) 1.315 1.660 1.900 2.375 2.875 3.500 4.500 , I.D. (in) 1.049 1.380 1.610 2.067 2.469 3.068 4.026 Schedule 40 Empty Weight(Ibs/ft) 1.680 2.270 2.720 3.660 5.800 7.580 10.800 Water-Filled Weight(Ibs/ft) 2.055 2.918 3.602 5.114 7.875 10.783 16.316 C.R.R. 1.00 1.00 1.00 1.00 1.00 1.00 1.00 Metric conversions table is also available `Al!Weights are Nominal N/A:Not Applicable PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket, pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 05/08 , 4 The Cost Effective Replacement for Schedule 10 Realizing the growing need of fire protection systems systems with a working pressure of 300 psi or less. in commercial and residential construction, Bull Please check with appropriate sources for up-to-date Moose Tube has added Eddy Flow to its listings and approval information. comprehensive line of sprinkler pipe products. As an added benefit, it is more economical to use than Eddy Flow is a specially engineered replacement for schedule 10 due to reduced delivery costs and ease schedule 10, offering better flow characteristics while of handling. Furthermore, Eddy Flow's larger ID providing design flexibility. This product is FM provides an opportunity for downsizing and further approved, as well as UL listed (for U.S. and Canada) cost savings. for roll grooving and welding for use in fire protection COMPARISON INSIDE DIAMETER C.R.R.' Nominal Pipe Eddy Flow Schedule 10 Schedule 40 O.D. (in) (in in Eddy Flow Schedule 40 Size in (in 1 1/4 1.660 1.530 1.442 1.380 1.98 1.00 1 1/2 1.900 1.728 1.682 1.610 3.44 1.00 2 2.375 2.203 2.157 2.067 2.78 1.00 21/2 2.875 2.705 2.635 2.469 1.66 1.00 3 3.500 3.334 3.260 3.068 1.00 1.00 4 4.500 4.310 4.260 4.026 1.00 1.00 * Corrosion Resistance Ratio BENEFITS • Dual Certified to ASTM A135 and A795. • FM Approved for roll grooved,and welded,and plain-end application in wet systems. • UL Listed(for U.S.and Canada)for Joining by welding or by listed rubber gasketed fittings for use In wet,dry, preaction,and deluge type sprinkler systems. • UL Listed(for US and Canada)and FM Approved for use with Victaulice File Fittings in plain end applications. • Lightweight-saves shipping costs,and offers easier handling. • Can be used with roll grooved couplings or welded outlets for pressures up to 300 psi. • Floor stock available in various lengths produced in Casa Grande(AZ),Gerald(MO),and Masury(OH).Also can be ordered In custom lengths.. • Can be used for wet and dry'systems. *Eddy Flow can be hot dipped galvanized to meet FM's requirement for thy systems. PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. Cli 1819 Clarkson Road For additional information, c I1� Bs Chesterfield,MO 63017 contact your salesperson today at 1 I BULL MOOSE TUBE C ANY (800)325-4467 (800)325-4467 or(636)537-2600 LISTED __—�V (� CCJJ FAX:(636)537-2645 in the USA,or from Canada www.bullmoosetube.com call(800)882-4666 ACOP�company e-mail:sales@bullmoosetube.com APPROVED All Information contained herein Is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without Incurring obligation. 8/08 f 4 FM Approved and UL Listed Sprinkler Pipe Bull Moose Tube Company is a recognized producer Bull Moose Tube's Sch. 10 and Sch. 40 pipes are of quality pipe products. Our Schedule 10 and made to ASTM A135 and ASTM A795. These Schedule 40 are FM Approved and UL Listed (for U.S. products are typically supplied with our protective and Canada), even though these products do not coating but can be supplied without the coating so require separate approvals and listings. Bull Moose they can be hot-dip galvanized to meet FM Tube made the decision to have them approved and requirements for use in dry systems in accordance listed for your peace of mind. Our Sch. 10 and Sch. 40 with the zinc coating specifications of ASTM A795 or have been through the same rigorous testing as our ASTM A53. All Schedule 10 and Schedule 40 pipe other fine pipe products. has a pressure rating of 300 PSI. Schodul„ 10 Pipo N!Q tnal Pipe Size(in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft Bundle Size t!!.krr 1 1.315 1.097 1.41 lbs/ft 91 1 1/4 1.660 1.442 1.81 lbs/ft 61 11/2 1.900 1.682 2.09 lbs/ft 61 2 2.375 2.157 2.64 lbs/ft 37 21/2 2.875 2.635 3.53 lbs/ft 30 3 3.500 3.260 4.34 lbs/ft 19 4 4.500 4.260 5.62 lbs/ft 19 ✓ — > Schedule 40 Pipe Nominal Pipe Size (in) Nominal O.D. (in) Nominal I.D. (in) Weight/Ft 111=1111 1 1.315 1.049 1.68 lbs/ft 70 1 1/4 1.660 1.380 2.27 lbs/ft 51 11/2 1.900 1.610 2.72 lbs/ft 44 2 2.375 2.067 3.66 lbs/ft 30 21/2 2.875 2.468 5.80 lbs/ft 30 3 3.500 3.068 7.58 lbs/ft 19 4 4.500 4.026 10.80 lbs/ft 19 PIPE PREPARATION For proper operation,all pipe surfaces should be cleaned prior to installation. In order to provide a leak-tight seat for the gasket,pipe surfaces should be free from indentations and projections from the end of the pipe to the groove. All loose paint,scale,dirt,chips,grease,and rust must be removed prior to installation. Failure to take these important steps may result in improper coupling assembly,causing leakage. Also,check the manufacturer's instructions for the specific fitting used. 1819 Clarkson Road For additional information, c uL us i"�'k (� M Chesterfield,MO 63017 contact your salesperson j l BULL MOOSE TUBE COA4NY (800)325-4467 today at(800)325-4467 or LISTED -"' l-1 FAX:(636)537-2645 (636)537-2600 in the USA, 41t> www.bullmoosetube.com or from Canada AaELKOcompany e-mail:sales@bullmoosetube.com call(800)882-4666 APPROVED All information contained herein Is accurate as known at the time of publication. Bull Moose Tube reserves the right to change product specifications without notice and without incurnng obligation. 12/09 ALL THREADED APPLICATIONS INSTALLED ON JOB t L E EDDY FLOW SCHEDULE 40 RIPE, PPE SPECIFICA to NS (Summary of certain information from ASTM Annual Book of Stc rdard) ASTM-A135 Rlectric Resistance Welded Steel Pipe Intended for conveying liquid, gas or vapor. Grade A Supplied as welded Adaptable for flanging and bending Physical requirements: Tensile Strength -48,000 psi minimum Yield Strength- 30,000 psi minimum Elongation in 2 inches - 15%to 36% depending on the cross sectional area of test specimen. Grade B (not made by RAM') Must be heat treated to 1000°F or similar Physical requirements Tensile Strength - 60,000 psi minimum Yield Strength-35,000 psi minimum Elongation in 2 inches - 29.5%to 12.5% depending on the cross sectional area of test specimen. Testing Flattening Test- appropriate destructive tests performed during manufacture Eddy Current Testing is a nondestructive electrical test performed on each piece of pipe in accordance with standard ASTM practice (E309) Hydrostatic Testing is optional and not performed on BMT pipe Permissible Variations Diameter may vary+/- 1%from the nominal size Thickness may not vary more than-12.5% of the nominal wall thickness. Notice that there is no positive tolerance on wall thickness, nominal wall equals maximum wall. Marking for each Iength of pipe is required • Packaging is per ASTM A700 ..'T' Products: a EDDYPIPE® Schedule 40, Schedule 10 1 „ey��'ss -"z-n ,'&. teeraa z,,�.sssF .,sraP I 1 l;t -Liglitwa1119-on rlireaclable Wipe. • EDDY FLOW® - Schedule 10 Replacement. EDDY1HREAD 40® - Lightweight ThreadablePipe with!;Corrosion ResistaM,e.itatiOS eq''al to or grea#erthan 1.0, and it t does rtothave a thread warring ' __--ii*._ ,' ' '. .- ' -_ ... ,. ....FITTINGS_av - s- -fill 1PE , ..,..,, ., ,...1 . .„ r� ..„....., -„.... ..,,:: _,,,,,:._ ..-.. ._. ,„:„. ,• , .. , ,- - -. -,40•44,„,-,- , 11 +,_.---y..� �, *l` t yt Y `!S a ,mot\ 1 nr-. r y, • 1 ey� v+' y tai t lig .. �"• ate-', a'x ' _:,..,.,..,,fi, .. ,,,,... ,, .,., . '''',.,:‘. _,, ilsos. , ,/, _.„,1,:. •i v `'�� ,....."00,T, 1+* _ aim V 44. - ^ yam, ^ ai. .-,.:°,7.-"--c r ' •� j$ }• rtr•i =."!-a- itilit . . ._. j{d�4 •A b d• t / n ate il y. Jl} ti'na - r ' `3 A4 THE WARD STORY Ward Manufacturing, Inc. was founded in Blossburg, PA by Mr. Joseph P. Ward in 1924. Beginning in a modest fashion with approximately thirty employees,a small line of cast iron steam and drainage fittings were manufactured along with cast iron plugs and bushings. In the following four years a rapidly increasing demand for Ward products was experienced. Accordingly, in 1928, the manufacturing facilities were doubled in r; size and cast iron steam fittings and the drainage fittings product lines were to include the 4" size. At the same time class 150 malleable fittings were introduced in sizes ranging from 118'through 4". During the next decade Ward continued to grow in size and stature and became an increasingly important factor in the American pipe fittings industry. Further expansion was completed in 1938 with the addition of a facility to produce malleable Iron pipe unions. These products,the "W & K" unions, were an immediate success and assumed a prominent position in Ward's product offering. Continued growth and the ever increasing demand for competitively priced products called for higher volume and more efficient molding facilities. To satisfy this business pressure,a totally new and highly automated foundry was erected in and,to this day, through careful maintenance, continuous improvement, and reinvestment,this facility is equipped with the most modern automatic molding equipment available. May 1980 marked another major milestone in Ward's history. Beginning with class 300 malleable fittings, a series of new product offerings were introduced into ' the Ward line including class 300 brass-to-brass seated unions, beam clamps, C-clamps,Wardlox plain end fittings,and Couplox grooved end fittings. 1990,the Teelox mechanical branch connector, meter swivels and ferrules, connecting nuts and a revolutionary new product called Wardflex,which is corrugated stainless steel interior gas piping, were added to Ward's catalog. These additions support our commitment to respond to the need of our customers. Ward distributes their products utilizing manufacturers' representative . groups in 50 states and Canada as well as off-shore countries. Since 1924 Ward has strived to maintain a leadership rote in the manufacture and distribution of piping components, We do this by striving first to meet our customers'expectations for high quality, competitively priced and promptly delivered products. We intend to continue with this philosophy. `�j SECTION 6 .�S{' 4'3,� ' F z + t STANDARD CAST IRON PIPE FITTINGS CLASS 125 .0.400ffzr:1 i:t - * The iron from which Class.125 cast iron fittings are made is held to strict formula by careful chemical analysis and control. Tapping is done on the most immessamo modern types of threading machines. All . „ , •••••°. tappings are to USA Standards for iron pipe threads. Straightness and correct depth of threads assured through continuous capable inspection, by carefully trained inspectors. Eve Mtn. Is hand sorted and inspected to eliminate defective castings. WARD fittings are made to specifications as published by the liti.;;'' e American National Standards Institute " (ANSI)for pipe fittings. They also .,„ ; conform to United States Federal Specifications. A chamfer is cut or cast in all ! openings, permitting easy entrance of 1 pipe and preventing damage to the first t ti hread in handling and threading. Because of the close attention paid to formula control together with the use of modern precision equipment we INE 0.0.of Band Thread Length Metal Thickness are able to produce castings of rugged min strength and ability to make up tight. 114 970 360 110 3/8' 1.160 .400 .120 1/2 1.380 .470 .130 3/4' 1.670 .540 .150 TEMPERATURE-PRESSURE RATING 1° 1.990 .620 .170 1114` 2.430 .710 .180 TEMP F PSIG 2.720 .740 .200 -20 TO 150 175 3.320 .790 ,220 200 165 11/2” 3.90 .960 .240 250 150 3 4.660 1.020 .260 300 140 3112" 5.240 1.070 280 350 125(see note 1) 4" 5.830 1120 .310 400 _... NOTES: Material: ASTM A126 Class A Minimum for cast iron 1) Permissible for service temperature up Dimensions: ANSI B 16.1 to 353 F reflecting temperature of ANSI B 1.20.1 for pipe threads saturated steam at 125 psig. Pressure Ratings: ANSI/ASME B 16.1 for cast iron 2)Permissible tor service temperature up Coatings: ASTM (ANSI), A 153 for galvanizing to 406°F reflecting temperature of saturated steam at 250 psig. Additional 30 Specifications:UL, ULC AND FM where applicable. Federal specifications WWP 501 CAST IRON STRAIGHT 90 ° ELLS FIGURE 21 Center Outside Thread Take Out NPS to End Dia,of Band Length Dimension A S(min) D(min) 114' 0.810 0.930 0.320 0,435 318" 0.950 1,120 0.360 0.575 1/2" 1,120 1.340 0.430 0.558 3/4" 1.310 1.630 0.500 0.746 f A 1" 1.500 1.950 0.580 0.813 [I 1114" 1.750 2,390 0.670 1.063 1- 1112" 1.940 2,680 0.700 1.253 1) r ,j 2" 2.250 3,280 0.750 1.500 8 �// 2112" 2.700 3.860 0.920 1.763 3" 3.080 4,620 0.980 2080 1� A 3112" 3.420 5.200 1.030 2.358 ,4" _ 3.790 5.790 1.080 2.665 1-0 ME \\--.-, CAST IRON REDUCING 90 ' ELLS IFIGURE 22 Center Center Outside Outside Length Length Take Take z NPS to End to End Dia.of Oa.of of of Out Out Band Band Thread Thread D1 X Z B1(min) B2{rnin) D1(min) D2(min) 1/2 x 3/8' 1.120 1.120 1.340 1 340 0.430 0.360 0.745 0.620 gee 3/4 x 112" 1.200 1.220 1.630 1 340 0,500 0.430 0.700 0.658 314 x 3/8" 1.200 1,220 1.630 1.340 , 0.500 0.360 0.825 0.658 1 x 314M ^ 1.370 .0 1.450 1.950 1.630 0.560 0,500 0.808 0-762 X 1 x 112 1,260 1.360 1.950 1.340 0.580 0.430 0.760 0.672 Mird, 02 1 114 x 1' 1.580 1.670 2290 1.950 0.670 0.580 0.893 0.982 1 114 x 314' 1.450 1.620 2.390 1.630 0.670 0,500 0,888 0.933 1 114 x 112" 1.340 1.530 2290 1.340 0.670 - 0.430 0.840 0.843 1 112 x 1 114" 1.820 1.880 2.680 2.390 0.700 0.670 ' 1.133 1.193 1 112 x 1" 1,650 1,800 2.680 1,950 0.700 0.580 0.963 1.113 1 1/2 X 3/4" 1.520 1,750 2.680 1.630 0.700 0.500 0.958 1.063 1 112 x 112" W 1.520 1,750 2.680 1.630 0.700 0.430 1.020 1.063 2 x 1 112` 2.020 2160 3280 2.660 0.750 0.700 1.333 1.410 2 x i 114" 1.900 2.100 3.280 2.390 0.750 0.670 1.213 1.350 0) 2 x 1" 1.730 2.020 3280 1.950 0.750 0.580 1.043 1270 2 X 3/4" 1.600 1.970 3.280 1.630 0.750 0.500 1.168 1.220 2 x 112 1.600 1.970 3280 1.630 0.750 0.430 1.100 1.220 2 1/2 x 2" 2.390 2,600 3.860 3.280 0.920 , 0.750 1.640 1.653 2 1/2 x 1 112" 2.160 2.510 3.860 2.660 0.920 0.700 1.473 1,573 ..5-.MI Vi S/A" n1nAn eACA ' On "J ann AOnn AR7f1 I .1 q 1a1Q G r!G/� r 1!Y G.VYV G.*1VV M.VVV L.J4V V-M-V V+VrV 1.-•..uu ,.u,v '21/2 X 1" 1.870 2,370 3,860 1.950 0.920 _0.560 1.183 1.433 2 112 x 314" 1.870 2.370 3.860 1.950 0.920 0.500 1.308 1.433 3 x 2 112" 2.830 2,990 4,620 3.860 0.980 0.920 1,893 1.990 3 x 2" 2.520 2.890 4.620 3280 0280 0.750 1.770 1290 3 x 1 112" 2;520 2290 4.620 3280 0.980 0,700 1,833 1290 3 X 1 114" 2,170 2,740 4.620 2.390 0.980 0.670 1,483 1.740 3 x 1" 2,170 2.740 ' 4,620 _2290 0.980 0580 1.483 1,740 -3 1/2 x 3" 3.420 3.420 5.200 5.200 1.030 0.980 2.420 2.358 4 x 3 112" 3.540 3.690 5.790 5.200 1.080 1.030 2.478 2.565 4 x 3' 3.300 3.600 5.790 4:620 1.080 0.980 2.300 2.475 4 x 2 112' 3.300 3.600 5.790 4.620 1.080 0.920 2.363 2.475 4 x 2" 2.740 3.410 5.790 3.280 1.080 0.750 1.990 2.285 4 x 1 112" 2.740 3,410 5.790 3.280 , 1.080 0.700 2.053 2.285 31 CAST IRON 45 ° ELLS FIGURE 2 3 Center to Outside Dia. Length of Take Out NPS End of Band Thread A 8(min) C(min) 1/2" 0.880 1.340 0.430 0.380 A 3/4" 0.980 1.630 0.500 0.418 - �1" 1.120 1.950 0.580 0.433 11/4` 1.290 2.390 0.670 0.603 1 1/2' 1.430 2,680 0.700 0.743 2" 1.680 $.280 0.750 0.930 2 1/2' 1.950 3 860 0.920 . 1.013 zs�� 3' 2.170 4,620 0-980 1.170 0E111,1 1 0 A 31/2° 2.390 5.200 1.030 1.328 t I i 4" 2.610 5.790 1.080 1.485 B _.y,/ CAST IRON STRAIGHT T E E S FIGURE 24 Center Outside Thread Take NPS to End Dia. of Band Length Out Dim, A B(min) D(min) 3/8" 0.950 1.120 0.360 0.575 1/2° 1.120 1.340 0.430 0.620 r-8 3/4° 1.310 1.630 0.500 0.748 II � 1" 1.500 1.950 0.580 0.813 , � �.; 11/4' 1.750 2.390 0.670 1.063 A - 11/2' t940 2.680 0.700 1.253 2' 2.250 3.280 0.750 1.500 _ 21/2" 2.700 3.860 0.920 1.763 3' 3.080 4.620 0.980 2080 sir/,. A 31/2" 3.420 5.200 1.030 , 2.358 ME�► D - 4 _ 3.790 5.790 1.080 2.665 A--4 32 CAST IRON REDUCING TEES FIGURE 25 C er-A 3 i . A2 1 D2 ` %I03 11 NI proi Hi , re - A trl 1--131----1 Center Center Center Outside Outside Oulslde Thread Thread Thread Take Take Take NPS To End To End To End Dia. Dia. Dia, Length Length Length Out Out Out H denotes Heel Ell of Band of Band at Band Al A2 A3 B1{min) 62(min) 1 3(min) D1(min) D2(min) r D3(min) 12 x 1/2 x 318 A 1.120 1.120 1.120 1240 1,340 1,340 0,430 0.430 0.360 0.620 0.620 0,745 1/2 x315 x 112 1,120 1.120 1.120 1.340 1.340 1.340 0,430 0.360 0,430 0620 0.745 0,620 1!2 x 3/8 x 378 1,120 1.120 1.120 1.340 1.340 1.340 0.430 0.360 0.360 0.620 0.745 0,745 3+8 x 3/8 x 1/2 1,120 1.120 1.120 1.340 1.340 1-340 0.360 0.360 0.430 0,745 0,745 0,620 3/4 x 314 x 1/2 1.200 1.200 1.220 1.630 1_630 1.340 0.500 0.500 0.430 ,_0.638 0-638 0,720 3/4 x 314 x 36 1.200 1,200 3.220 1.630 1.630 1.340 0.500 0.500 0.360 0.638 0.638 0845, 3/4 x 1!2 x 314 1,310 1.310 1.310 . 1.630 1.630 1.630 0.500 0.430 0.500 0.748 0.810 0.748 3/4 x 1/2 x 12 1.200 1.120 1.220 1.630 1.340 1.340 0.500 0.430 0.430 0.638 0,620 0.720 1/2 x 1!2 x 3/4 1.310 1.310 1.310 1.630 1.630 1.630 0.430 0.430 , 0.500 0.810 0.810 0.748 1 x 1 x 3/4 1.370 1.370 1.450 1.950 1.950 1,630 0,580 11580 0.500 0.683 0.763 0.888 1 x 1 x 1/2 1.260 1.280 1,360 1.950 1.950 1.340 0.580 0.580 0.430 0 57 0.673 0.860 1 x 1 x 318 1.260 1.260 1,360 1.950 1.950 1.340 0.580 0.580 0-360 0.673 0.673 0.985 1 x3/8 x 1 1,500 1,360 1.500 1.950 1.340 1.950 0.580 0,360 0.580 , 0.613 0.985 0.813 1 x 3/4 x 1 1,500 1,450 1.500 1.950 1.630 , 1.950 0,580 0.500 0.580 0613 0.888 0.813 1 x.3/4 x 314 1,370 1.310 1.450 1.950 1.630 1.630 0.580 0.500 0.500 0.683 0.748 0.888 1 x 3/4 x 1/2 1.260 1.260 1.360 1,950 1.950 1.340 0.580 0.500 0,430 0,573 0.698 0,860 1 x 112 x 1 1.500 1.360 1,500 1,950 1.340 1.950 0.580 . 0.430 0.580 0.813 0-860 0,813 1 x 1/2 x 314 1.370 1.310 1.450 1.950 1230 1.630 0.580 0,430 0.500 0.683 0.810 0.888 1 x 1/2 x 1/2 1.260, 1,129 1.360 1.950 1.340 1.340 0.580 0,430 0.430 0.573 0.620 0.660 1 x 114 x 1 1.500 1,200 1,500 1.950. 0.930 .. 1250 0580 0.320 0.580 0,813 0225 0,613 , 3/4 x 3/4 x 1 1.500 1.450 1.500 1.950 1,630 1.950 0.500 0.500 0.580 0.938 0.888 0,813 3/4 x 1/2 x 1 1.500 , 1,360_, 1,500 1,950 1.340 1.950 0.500 0.500 0.580 0.938 0,860 0.813 1 114 x 1 1/4 x 1 1,580 1.580 1,670 2.390 2.390 1.950 0.670 0.670 0.580 0.863 0.893 0.983 1 1/4 x 1 114 x 314 1.450 , 1.450 1.620 2.390 2.390 1.830 0,670 0.670 0.500 0.763 0.763 1.058^ 1 114 x 1 114 x 1/2 1.340 1.340 1,530 " 2290 2,390 _ 1.340 A 0270 0270 0:430 0.653 0.653 1,030 1.1/4 x t x 1 1/4 1750 1,670 1.750 2.390 1,950 2,390 0,670 0,580 0.670 1:063 0.983 1.063 1 114 x 1 x 1 1.580 1.500 1.670 2,390 1.950 1.950 0.670 0.580 _ 0.580 0,893 0.813 0.983 1 1/4 x 1 x 3/4 1,450 1.370 1,620 2,390 1.950 , 1.630 0.670 0.580 0.500 -0,763 0.683 1.058 1 1/4 x.1x 1/2 1,340 1.260 1,530 2,390 1.950 1,340 0.670 ,, 0,580 0430 1.653 0.573 1230 1 1/4 x 314 x 1 1/4 1750 1220 1:750 2.390 1.630 2,390 0.670 0500 0670 1263 1.058 1263 1 1/4 x3/4 x 1 1.680 1,450 1.670 2.390 1.630 1,950 0,670 0.500 0.580 0,893 0.888 0.983 1 1/4 x 3/4 x 314 1.450 1.310 1.620 2.390 1.630 . 1.630 0.670 0.500 0.500 0.763 (1748 1,058 1 1/4 x 3/4 x 1/2. _ 1,450 1.310 1.620 2.390 1 1.630 1.630 0,670 0.500 0.430 0.763 0.748 1.120 1 1/4 x 1/2 x 1 1/4 1.750 1 63 1.750 2.390 1.340 2.390 0.670 - 0.430 0.670 1,063 1.030 1.063 1 1/4 x 112 x.1 1.750 1.530 1.750 2.390 1.340 2,390 0.670 0.430 0.580 1.063 1.030 .1.063 1 o 075 1 114x1i2x3i$ i,aisv 1.450 1.450 iav`ir = 1.340 1 i,i2u" 3.670 0.43"v 0.3u^v v.oS3 0.950 i.vro 1 1/4 x 1/2 x 1/2 1,340 1.120 1.530 2.390 1.340 . 1,340 0.670 0.430 0.430 0.653 0.620 1.030 1 1/4 x 1/2 x 3/4 1.450 1.310 1.620 2.390 1.630 1.630 0.670 0,430 0.500 0,763 0.810 1.058 1 1/4 x 1(4 x 1 114 H 1,750 1530 1,750 2.390 0.930 2.390 , 0,670 0.320 0.670 1.063 1,155 1.063 1 1/4 x 1/8 x 1 1/4 H 1.750 1-530 1,750 2.390 , 0.810 _ 2.390 0.670 0.320 0.670 1.063 1.280 1.963 1 x ix 11/4 1.750 1.620 1.750 2.390 1.630 , 2290 0.580 0.580 0.670 1.063 0.983 1.063 I x 314 x 1 1/4 1.750 1,620 1.750 2.390 1.630 2.390 0.580 0,500 4 0.670 1.063 1,050 1.063 1 x 1/2x 1 1/4 1,750 1.530 1.750 2.390 1.340 2.390 0.580 0.430 0.670 1.063 1.030 1.063 1 1f2 x 1 1/2 x 1 1/4 1.820 1.820 1.880 2.680 2.680 , 2.390 0,700 , 0.700 1670 1.133 1.133 1.193 1 1/2 x 1 1/2 x 1 _1.660 1.650_ 1.800 2,680 2.680 1.950 0.700 0.700 _ 0.580 0.963 0.963 1.113 1 1(2 x 1 1/2 x 3/4 1.520 1.520 1.750 2.680 2,680 1,630 0.700 0.700 0.500 0.833 0.833 1,188_ 1 1/2 it 1 1/2 x 1/2 1.410 1.410 1.660 2.680 2,680 1.340 0.700 0.700 0.430 0.723 0.723 1.160 1 112 x 1 1/2 x 3;8 1.410 1.410 1.660 2.680 2.680 1.340 0.700 0.700 , 0.360 0..723 0.723 1.265 1 1.12 x 1 1/4 x 1/2 • 1,940 1,880 1.940 2.680 2.390 2.680 0.700 0.670 0.670 1.253 1.193 1.253 1 112 x 11/4 x 11/4 1,820 1,750 1,880 , 2,680 2.390 2390 0.700 0.670 0.670 1,133 1.063 1,193 33 CAST IRON REDUCING TEES 82---1 FIGURE 25 1 r-A3 D2 all -j D3 rte\ ,/� I�r/...� A 63 Al 1 D1 ' 1 131 1 _� Center Center Oenter Outside Outside Outside - Thread Thread Thread Take ' Take Take NPS To End To End To End Dia. Dia. Dia. Length Length Length Out Out Out H denotes Heel Ell of Band of Band of Band Al A2 A3 B I min) B2(min) B3{min) DI(min) D 2jmin) D3(min) 1 1/2 x 1 1/4 x 1 1.650 1.580 1.800 2.680 2,390 1.950 0.700 0.670 0.580 0.963 0.893 1.113 1 1/2 x 1 1/4 x 3/4 1.520 1,450 1.750 2.680 2390 1.630 • 0.700 0.670 0.500 0.833 0.763 1.188 I 1/2 x 1 114 x 1/2 1.410 t340 1.660 2.680 2.390 1.340 0.700 0.670 0.430 0.723 0.653 1.160 1 1/2 x 1 x 1 1/2 1.940 1.880 1.940 2.680 1.950 2.680 ' 0,700 0.580 0.700 1.253 1.113 1.253 1 1/2 x1 x 1 1/4 1.940 1.600 • 1.940 2.680 1.950 2-680 0.700 0.580 0.670 1.253 1.113 1.253 1 112 x 1 x 1 1.650 t 500 1,800 2.680 1.9,50 1.950 0,700 0.c`00 0.580 0.963 1 0.813 - 1.113 1 1/2 x 1 x 3/4 1.650 1 1.50;7 1.800 2.680 k 950 1.950 0.700 0.580 0.500 0 963 0.813 1.238 1 1/2 x 1 x 1/2 1A10 1.340 1.660 2.680 2 390 1249 0.700 0.580 0.430 0,723 0653 t 1.160 1 1/2 x 314 x 1 1/2 1.940 1.750 1.940 2,680 1.630 ' 2.680 0.700 0.500 0.700 1.253 1.188 1.253 1 1/2 x 314 x 1 114 1.940 1.750 1.940 2.680 1,630 2.680 ' 0.700 0.500 0.670 1.253 1.188 1.253 1 1/2 x 314 x 1 1.650 1.500 1200 2680 1,950 1.950 0.700 0.500 0,580 0.963 0.938 1.113 1 1/2 x 314 x 314 1.650 1.500 ' 1.800 2.680 1.630 1,630 0.700 0,500 0.500 0.963 0.938 1.238 1 1/2 x 314 x 112 1.525 1.375 1.800 2.680 1.630 ' 1.630 0.700 0.500 ' 0.430 0.836 0.813 1.300 1 1/2 x 1/2 x 1 1/2 1.940 1.660 1.940 2.680 1.340 2.680 0.700 0,430 0.700 1.253 1.160 1.253 1 I/2 x 1/2 x 1 114 1.940 1.660 1,940 2.680 1,340 2.680 0.700 0.430 0.670 - 1.253 1.160 1.253 1 1/2 x 1/2x3/4 1.525 1.375 1.800 2.680 1.630 1.630 0,700 0,430 0.500 0.838 0.875 1.238 1 1f2 x 1/2)(1/2 1,525 1.375 1.800 2.680 1.630 1.630 0.700 0.430 0.430 0.838 0.875 1.300 1 1/4 x 1 1/4 x 1 1/2 1,940 1.880 1.940 2.680 2.390 2.680 0.670 0.670 0.700 1.253 1.193 1.253 1 1/4 x 1 x 1 1/2 1.940 1.800 1.940 2.680 1.950 2,680 0.670 0.580 0.700 1.253 1.113 1.253 1 1/4 x 3/4 x 1 112 . 1.940 1.750 1,940 2.680 1.630 2.680 0.670 0,500 0.700 1.253 s 1.188 1.253 1 1/4 x 1/2 x 1 1/2 1.940 1.660 1.940 2.680 1240 2.680 0.670 0.430 0.700 1.253' 0.973 1.253 2 x 2 x 1 112 2 020 2.020 -2,160 I 3,280 3.280 ,. 2.680 0.750 0.750 0,700 1,270 ' 1.2711 1.473 2x 2 x 1 1/4 A 1.900 1.900_ 2,100 3.280 ' 3.280 2.390 0,750 0.750 . 0670 1.150 1.150 1.413 2 x 2 x 1 , 1.730 1.730 2.020 3.280 3.280 1.950 0.750 0.750 0.580 0.980 0.980 1.333 2 x 2x3/4 1,600 1.600 1.970 3.280 3.280 1.630 0.750 0.750 0.500 ' 0.850 0.850 1.408 2 x 2x11_2 1.490 1.490 1.880 3.260 3.280 1.340 0.750 _ 0.760 _ 0.430 0.740 0,740 1,380 2 x 1 1/2x 2 2250 2.160 2250 3.280 2.680 ' 3.280 0750 0.700 0.750 1.500 1.473 _ 1,500 2 x 1 112x 1 1/2 2.020 1.940 2.160 3.280 2.680 2.680 _ 0.750 0.700 + 0.700 1,270 1.253 1.473' 2 x 1 112x 1 1/4 2.020 1.940 2.160 3.260 2.680 2.680 0.750 0.700 0.670 ' 1.270 1.253 1.473 2 x t 112 x 1 1.730 1 1.650 2.020 3.280 2.680 1.950 "0.750 0.700 0.670 0.980 0,963 1.333 2 x 1 112 x3+4 1.600 1.520 1.970 3.280 2.680 1.630 0.750 0.700 0.500 0.850 0.833 1,408 2 x 1 1/2 1/2 1 A90 1.410 1,880 3.280 2680 1.340 0.750 0700 0.430 0.740' 0,723 1.380 2x 1 1/4x2 2.250 2.100 2.250 1280 2390 1280 0,750 0.670 0.750 1.500 1.413 1.500 2 x 1 1/4 x 1 1/2 2020. 1,940 2.160 3.280 2680 2880 0750 0.670 0700 ' 1.270 ' 1.253 1.473 2 x t 114 x 1 114 1.90D 1,750 2.100 1280 2290 2390 0750 0,670 0.670 1.150 1,063 1.413 2X1 1/4x1 1.900 17500 2.100 3,280 2.390 2.390 0.750 0.670 0.580 1.150 1.063 1 1.413 2 x 1 114 x 1/2 1.490 1.410 1,880 3.280 2.680 1.340 0,750 0.670 0.430 0.740 • 0.723 1.380 2 x 1 x 2 2.250 2.020 2.250 3.280 1.950 3.280 0.750 0.580 0.750 1.500 1.333 1.500 2 x 1 x 1 1/2 2250 2020 2,250 3.280 1.950 a 280 0,750 0.580 0.700 1.500 1.333 1563 2 x 1 x 1 1/4 1.900 1.750 2,100 3.280 2290 2.390 0.750 0680 0.670 1.150 1.063 1.413 2i 1 x 1 -1.730 1.940 T 2.020 3230 1.950 1.950 0.750 0.580 0,580 ' 0,980 1.253 1.333 2 x 1 x314 1.730 1.940 2.020 3.280 1.950 1,950 0.750 0.580 ' 0600 0.980 1.253 1.458 2x3i4x2 2.250 1.970 . 2,250 3.280 1.630 3.280 0.750 0.500 0.750 _ 1.500 1,408 1.500 2x3/4x1 112 H 2.250 1,970 R 2.250 3.280 1,633 _ 3.280 0.750 0,500 _ 0.700 1.500 1,408 1.563 2 x3.',1 x 1 114 2 250 1.970 2.250 3.280 1.630 3280 0-750 0500 0,670 1.500 1,408 1.563 2 x 14 x 1 _ 1.730 1,940 ' 2.020 3.280 1.950 A 1,950 0.750 0.500 0,580 0.980 1.378 1.333 2 x 314 x14 1.600 1.600 1.970 3.280 1.630 1.630 0.750 0.500 0.500 0.850' 1,038 1.408 2x 3/4 x 1:'2 1.600 1.600 1.970 3.280 1.630 1.630 0.750 0.500 0.500 0.850 1,038 1.470 2 x 112 x 2 2.250 1.860 2.250 3180 1.340 3280 0.750-. 0.430 0,750 1.500 1.380 1,500 2 x 112 x 1 1.2 2.020 1.660 2.160 , 3,280 1.340 2.690 0.750 ' 0.430 0.700 1.270 "1.160 1,473 34 milimilimimiimil CAST IRON REDUCING TEES �` FIGURE 25 f 82 A3 02 ■ D3 _ �� A2 1 fr G 1: -B3 Ai --Art 1 D1 gni 1 1- B1 1111111'\-Int NPS Center .Center Center Outside Outside Outside Thread Thread Thread Take Take Take To End To End To End Dia. Dia. Dia, Length Length Length Out Out Out H denotes Heel Eli of Band of Band 01 Band Al A2 A3 81(min) B2(min) 133(min) D1(min) D2(min) D3{min) 2 x 1/2 x1 1/4 1.730 1.730 2.020 3.280 1.340 2.680 0.750 0.430 0.670 1.270 1.160 1.473 2 x112 x 314 1.600 1.600 1.970 3.280 1.630 1,630 0.750 0.430 0.500 0.850 1.100 1,403 2 x112 x 1/2 1,600 1.600 1.970 3.280 1.630 1.630 0.750 0.430 0.430 0.850 1.100 7.470 1 112 x 1 112 x 2 2.160 2.160 2.020 2.680 2.680 3.280 0.700 0.700 0.750 1.473 1.473 1.270 1 112 x 1 1/4'x 2 2.250 9.100 �7.2Fn 3.280 2.390 . 3 280 0.700 n.070 0.750 1.563 1.4 13 1.500 1 1/2 x 1 x 2 2.250 2,020 2.250 3.280 1.950 3.280 0.700 0.580 0.750 1.563 1.333 1.500 2 1/2 x 2 1/2 x 2 2,390 2.390 2.600 3.860 3.850 3.280 0.920 0.920 0.750 1.453 1.453 1.850 2 1/2 x 2 112 x 1 112 2.160 2.160 2.510 3.860 3.860 , 2.680 0.920 0.920 0.700 1.223 1.223 1.823 2 1/2 x 2 112 x 1 1/4 2.040 2.040 2.450 3,860 3.860 2.390 0.920 0.920 0.670 1.103 7.103 1.763 21/2x 21/2 x 1 1,670 1.870 2.370 3.860 3.860 1.950 0.920 0.920 0.580 0.933 0.933 1.683 2 112 x 2112 x 314 ' 1,870 1.870 2.370 3.860 3.860 1.950 0.920 0.920 0.500 0.933 0.933 1.808 2 1/2 x 2 12 x 1/2 1.870 , 1.870 2.370 , 3.860 3.860 1.950 0.920 0.920 0.430 0.933 0.933 1.970 2 1/2 x 2 x 2 1/2 2.700 2.600 2.700 3.860 3.280 3.860 0,920 0.750 0.920 1.763 1.850 1.763_ 2 1/2 x 2 x 2 2.390 ..2.250 2,600 3.860 3280 3.280 0.920 0.750 0.750 1.453 1,500 1.850 2 1/2 x 2 x 1 112 2.330 1 2.250 2.600 3,860 3280 3.280 , 0.920 0.750 0.700 1.453 1.500 1.913 2 112 x 2 x 1 114 2.040 1.900 2.450 3.860 3.280 2.390 0.920 0.750 0,670 1.103 1.150 1.763 2 112 x2 xl 2.040 1.900 2.450 3.860 3.280 2.390 0.920 0.750 0.580 1.103_ 1.150 1.763 21/2 x 2 x3/4 1,870 1,870 2.370 3860 3260 1.950 0820 0.750 0980 0.933 1.120 1.808 2 1/2 x 2 x 1/2 1.830 1,490 2230 3960 3.280 , 1.340 0-920 , 0,750 0.430 0.693 0.740 1730 21/2 x 1 1/2 x 2 1/2 2.700 2.510 2.700 3.860 2.680 3.860 0.920 0.700 0.920 1.763 1.823 1,763 21/2 x 1 1/2x2 2.390 2.250 2.600 3.860 3.280 3.280 0.920 0.750 0.750 1.453 1.563 1.850 21/2 x 1 1/2 x 1 112 ,.2.160 1.940 2.510 3.86.0 2.680 2.680 0.920 0-700 0.700 1223 1.253 1.823 21/2 x 1 112 x 1 114 2.040 1.900 2.450 3.860 3.280 ^ 2.390 0.920 0.700 0.670 1.103 1.213 1,763 2 112 x 1 112 x 112 1,630 1.490 2.230 3.860 3.280 1.340 0,920 0.700 0.430 0.693 0.803 1.739 21/2 x 1 114 x 2 112 2.700 2450 1700 3.860 2290 3.860 0.920 0,670 0.920 1.763 1,763 1763 21/2x 11/4 x2 , 2700 2,450 1700 3.860 2,390 3.860 0.920 0.670 0.750 1-763 1,763 1950 21/2)(11/4 x 1 112 2160 1840 2.510 3.860 , 2.680 2.680 0920 0.670 0.700 1.223 1.253 1.823 21/2 x 1 1/4 x 1 114 2,040 1900 2.450_ 3860 _ 2:390 2.390 0920 0.670 0.670 1.103 1.213 1,763 , 21/2 x 11/4x 1 2.140 2.120 2.510 3.860 1390 2.39D 0920 0.670 0.580 1,203 1.433 1..823 21/2 x 1 x 2 1/2 2.700 2.450 2.700 3.880 2.390 3.860 0920 0.580 0.920 1.763 1.763 1.763 21/2 x 1 x 2 2.700 2.450 2.700 3.860 2.390 3.860 0.920 0.580 0.700 1.763 1.763 1.950 21/2 x 1 x 1 114 1140 2,120 2310 3.860 2.390 2.390 0.920 0.580 0,670 1.203 1.433 1.823 21/2x 1 x 1 1.940 1.750 2.370 3,860 1.950 1.950 0.920 0.580 0.580 7.003 1,053 1.683_ 21/2 x 1 x 3/4 1.940 1.750 2.370 3.860 1-950 1.950 0.920 0.580 0.500 7.003 1.063 1.808 2 112 x 3/4 7t 2_11J , 2.700 9 20 4 700 3 850 1 7 3 555 0 2a firm ��JJ c 9 C.,1vu 0.920 7.763 1.758 1.763 . .. � �.:]�v r..vv v.vvv x.8..4 V-VV'J V. 4Y '212)(34 x 2 H 2.700 2.320 2.700 3.860 , 1.630 1860 0.920 0.500 0,750 1.763 1.758 1.950 21/2 x314 x 1 1,940 1.750 2.370 3.860 1.950 1.950 0.920 0.500 „OLEO 1.003 1.188 1.683 21/2 x 314 x 3.14 1-940_1.750 2.370 3.850 1.950 1.950 0.920 0.500 0.500 1.003 _1.188 1.808 21/2 x 1/2 x 2 1/2 H 2.700 2.230 2.700 3.860 1.340 3.860 0.920 0.430 0.920 1.763 1.730 1.763 21/2 x1/2 x 2 H 2.700 2.600 2.700 , 3.860 1.340 3.860 0.920 0.430 0.750 1.763 2.100 1,950 2 x 2 x21/3 2.600 _2.600 2.390 3.280 3280 3,860 , 0.750 0.750 0920 1950 1950 1,453 2 xi 1/2 x2 112 2.600 2.600 2.390 3.280 3.280 3.860 0.750 0.700 0,920 1.850 1.913 1.453 2 x 1 1/4 x 2 1/2 2.700 2.450 2.700 3.860 , 2.390 3.880 0.750 0.670 0.920 1.950 1.763 r 1.763 2 x 1 x 2 1/2 2.700 2.450 2.700 3.860 2.390 3.860 , 0.750 , 0.580 0.920 1.950 1.763 1.763 2 x 3/4 x 2 112 H 2.700 2.320, 2.700 3.860 1.630 , 3.860 0.750 0.500 0.920 1950 1,758 1.763 7 112 x 1 / x 2 1I2 2.510 2.510 2.160 2680 2.680 3.860 0.700 0.700 0.920 1.823 1.823 1.223 x 0 2.830 2.990 4.620 4.620 3.860 0.980 0.980 0.921 ' • .1 3 x3 x2 2520 2. 4.620 •. :1 •.._. ..r:11 0.750 1.520 1.520 2.140 3x3x11/2 2.520 2. • _•• •.. I . :r I •:0 0.700 1,520 1.520 2.203 3 x x 1 3.0 2.170 2.740 4.620 4.620 2.390 0,980 0.980 .053_ 35 CAST IRON REDUCING TEES _ FIGURE 25 12-1 r--A3 D2 all - D3 % %I iJ �/ '• .'d ■ Al Ai)) � w B� I Di I-131 NIPS Cente Center Center Outside Outside Outside Thread Thread Thread ',ke Take Take To End '. End To End Dia. Dia. Dia. Length Length Length Out Out Out H denotes Heel Ell of Band at Band of Band Al A3 B1(min) D2(min) B3(men D1(min) D2(min) 103(mi• 3 x 3 xl 2.000 2.000 2.660 4.620 4.620 1.950 0.980 0.980 0. •0 1,000 1,000 1.973 3 x21/2 x 3 3.080 2.990 .80 4.620 3-860 4.620 0,980 0.920 0.'80 2.080 2.053 2.080 3 x 2 1/2 x 2122 2.630 2.700 2.••1 4.620 3.860 3.860 0.980 0,920 0.920 1.830 1,763 2.053 3 x 21/2 x 2 2.830 2.700 2.99. 4,620 3.860 3.860 0.980 0.920 0.750 1.830 1.763 . 2.240 3 1.4 2,170 2.170 2.740 [,620 4,620. 2.390 0.980 0.9 • ` 0,670 1.170 1.233 2.053 hc eecx a ir 3x 2 x 3 3.080 2.890 3.030 •,• 0 3.280 4.620 0.980 0 0 0.980 2.080 2.140 2,080 3 x 2 x21/2 3.080 2.890 3.080 4.6 • 3.280 4.620 0.980 ..750 0.920 2.080 2.140 2.143 3x 2 x2 2.520 2250 2290 4.620 3.280 3.280 0.980 0,750 0.750 1520 1.500 2.140 3 x 2 x 1 1/2 2.520 2.253 2890 4.620 3280 3,280 0.980 0.750 0.700 1520 1.500 2.203 3x 11/2x 3 3,030 2.890 am 4,620 80 4.620 02:• 0.700 0980 2.080 2.203 2080 3x 11/2 x 2 2.520 2.250 2.890 4,620 3.2.4 3280 1 :80 0-700 0,750 1.520 1,563 2.140 3x 1 1/2 x 1 1/2 2520 2.250 2.890 4.620 3.280 3.230 1,980 0700 0.700 1.520 1463 2.203 3 x 1 1/4 x 3 H 3.080 2,740 3.080 4.620 _ 2.390 4.620 0.980 0.670 0980 2.080 2.053 2.060 3 x 1 1/4 x 2 H 2.520 2.700 2.890 4.620 2290 81 0.980 0.670 0.750 1,520 2.013 2.140 3 x 1 x 3 H 3.080 2.740 3,080 4.620 1.950 4.a'1 0.960 0.580 0.980 2.080 2.053 F 2.080 3 x 1x 2 H 2.520 2.630 2.890 4.620 1.950 :t 0.980 0.580 0.750 1220 1.943 2,140 3 x 3/4x 3 H 3.084 2.610 3.080 4.620 1.630 4.620 0,980 0.500 0.980 2.080 2.048 2.080 1 1/2 x 1 1/2 x 3 2.830 2.830 2.275 2.690 2.680 4.620 '700 0.700 0.980 2143 2.143 1.275 _ 2 x 2 x 3 3.080 2.890 3.080 4.620 3281 4.620 0. 0 0.750 0.980 2.330 2.140 2.080 2 1/2 x 21/2 x 3 3.080 2.990 3.080 4.620 3.:•0 4.620 0.921 0.920 0.980 2.143 2.053 2.080 21/2x 2 x3 _ 3.080 2.890 3,080 4.620 .280 4.620 0.920 0.750 0-980 2.143 2.140 2.080 3 1/2 x 3 1/2 x 4 3.790 3.790 3.790 5,790 5,790 5.790 1.030 ' 030 1.080 2.728 2.728 2.665 31/2 31/2x31/2x3 3420 3.420 3,420 5200 5200 5,200 1.030 1,, 0 0.980 2.358 2,358 2.420 3 112 x 3 112 x 21/2 2.930 2.930 3.240 521' 5.200 3,060 1.030 1.034. 0.920 1.868 1.868 2,303 3 112 x 31/2 x 2 2220 2,620 3.140 5 I 5,200 3.280 1.030 1.030 0,750 1559 1.558 2.390 3 1/2 x 3 1/2 x 1 1/2 2;390 2.390 3.050 11 5:200 2.680 1.030 1.030 1,700 1.703 1.328 2.363_ 3 1/2 x 3 1/2 x 1 114 2.270 2270 2.990 5.200 5.200 2.390 1,030 1.030 0., 0 1.208 1.208 2.303 3 1/2 x 3 112 x 1 2.100 2.100 2.910 5.200 5.200 1.950 1.030 1.030 0. :•. 1.038 1.038 2,223 3 1/2 x 3 x 31/2 3.423 3.420 3.••-0 &no 5200 5200 1.030 0.980 1.030 2.358 2.420 2,358 3112 x 3 x 3 3.420 3.420 .420. 5.200 5.200 5.200 1.030 0.980 0.980 358 2,420 2.420 31(2 x 3 x 21/2 2.930 2.830 3.240 5.200 4.620 3.860 1.030 0.983 0.920 1. 1.830 2.303 3112 x 3 x 2 2.620 22 • 3.140 5200 4.620 3,280 1.030 0.980 0.750 145 1.520 2.390 3 112 x 3 x 11/2 2,390 •0 3,050 5200 4.620 1860 1.030 0280 0350 1228 ,290 2263 3 1/2 x 3 x 1 1/4 2.390 '.290 3.050 5.200 4.620 2.390 1.030 0.980 0.670 1.328 1. 0 2.363 31:2 x 1 114 X 33 1/2 e H 3 2^ r '200 ' 2 390 5.200 1,030 0.670 ' 1.030 4 2.358 2.30 2.733 o.•ec c.990 3.42V acuu e.�au 31/2 x 1 x 3 1/2 H 3.4 • 2.910 3.420 5.200 1.950 5.200 1.030 0.580 1.030 2.358 2.223 258 3x 3 x 31/2 _ •20 3.420 3.420 5.200 5,200 5.200 0.980 0.980 1.030 ' 2.420 2.420 . 8 4 x 4 x 3 1/2 _., .790 3.790 3,790 5.790 5.790 5.790 1.080 1.080 1,030 ' 2.665 2.665 2.7 4 x4 x3 3.300 3.300 3.600 5.790 5.790 5.200 1.080 1.080 0.980 2,175 2.175 2.600 4 x 4 x21/2 3.050 3.050 3.510 5.790 5.790 3.860 1.080 1.080 0,920 1.925 1.925 2.760 4 X4 x2 2.740 2.740 3.410 5.790 5.790 3.280 1.080 1.080 0.750 1.615 1.615 2.660 4 x4 x.11/2 2.740 2.740 3.410 5.790 5.790 3.280 1.080 1.083 0.700 1.615 1.615 2.723 4 x 3 1/2 x4 3.790 3.790 3.790 5.790 5.790 5.790 1,080 1.030 1.080 2.665 2.728 2.665 4 x 3 x4 3.790 3.600 3.790 5.790 4.620 5.790 1,080 0.980 1.080 2.665 2,600 2.665 4 x 2 1/ 4 3.790 3.510 3,790 5.790 3.860 5.790 1.083 0.920 1.080 2.665 2.573 2.665 4x2 . 3.790 3.410 3.790 5.790 3.280 5,790 1.080 0.750 1.080 2.665 2.6607 2.665 4 x 1/2 x 4 3.790 3.410 3.790 5.790 3.280 5.790 _ 1.080 0,700 1.080 2.665 2.723 2.665 4 1 1/4 x 4 H 3.790 3,260 3.790 5.790 , 2.390 5.790 1.080 0.670 1.080 2.665 2.573 2.665 x 1 x 4 H 3.790 3.180 3.790 5,790 1.950 5.790 1.080 0.580 1.080 2.665 2.493 2.665 • 4 x 3 1/2 x 3 112 3.790 - 3.790 3,790 5.790 5.790 5.790 1,080 1.030 1 1.030 2.685 2.728 2.728 , CAST IRON REDUCING TEES • B2 FIGURE 25 4 _ r..i D2 1a D3 A2 ! v L ,r.�os, �- A B3 I1 ° %'1# ' 1 1 B1 Center Center Center Outside Outside Outside Thread Thread Thread Take Take . To End To Eitd To End : Dia. Dia. Dia. Length Length Length Out i0 _ of Band of Band of Band 1 A 2 A 3 BI(min) B 2(min) S 3(min) D1(min) 02(min) 03(min) 4 x 3 1/2\3 iT_ 3.300 3.600 5.990 5200 4.620 1.080 1030 4. f 2.176 2.238 2.600 4 x 3 12 x 2 1/2 3.050 illki 3.510 5.790 5790 3.660 1.080 1.030�"-9320 1.925 1.988 pm 4 x 3 172 x 2 2.740 2.620 ��0 5.790 5200 3:280 1.80 K' 0.750 1,615 1.559 2.660 4 x 3 112 x 1 1/2 2.510 2-390 3.320. 2.680 1.-7. 1.030 0.700 1.335 1,320 2.663 4 x 3 x 31/2 3a790 3.690 3.790 `al_ 3.860 5.790 1.080 0,980 1.030 2.665 2.690 2.728 4 x 3x 3 1540 3.420 3,690 .5.790 VIVO, 1060 0.980 0.980 2415 2.420 2.699 4 x 3 x 21/2 3.300 3.080 3.600 5.790 WjEalth,860 1.080 0.980 0.920 IBM 2.080 2.663 Ingin 2.740 2.620 3.410 5.790 .200x_ 1.080 0.980 0.750 1.615 1,620 2.660 ® 2.510 2.390 3.320 11V-2.0 5200 2.680 '. 0.980 0.700 1.385 1.390 2.633 4 x 21/2x 3 3.300 3.080 6.790 3.860 3,860 1.080 6,1.920 0.98D 2-175 2.143 2.600 4 x 2-1/2x 21/2 3:050 M:' 3.510 5.790 3.280 1280 1.080 0,9 711111 0.920 1.925 1.763 2.573 3.050 00 3.540 5.790 3.860 3-660 1.080 0.920 111617111 1.925 1363 2.760 4 x 2 x 2 tail 2.259 3.410 5.790 3.280 3.280 1,080 0.750 0,750 art 1.500 2.660 2.740 2.250 3,410 5.790 3.280 3280 1,080 0.750 0.700 1.61� .500 2.723 4x11. 2.740 2.250 3.410 5.700 3280 3280 1.080 0.700 0.750 1,615 _2-660 t,`ilifilaian 2,740 2.250 3.410 5,790 1,950 5.790 1.080 0.700 0.700 1.615 1,563 EVJ CAST IRON REDUCING COUPLINGS FIGURE 29 Outside Outside Take Take Length Dia. Dia. Out Out of NPS of Band of Band Fitting HA2-°-I Al (min) A2(min) D Ni •'H_Y"a" l 11 x 314"' 1.990 1.625 0.270 0.350 1.700 1 x 112"'" 1.990 1:313 0.270 0.420 1.700 t 1 1114x I 1..3JV I.`JDV v.3o7 u.4ti7 1,Liu , 1. . ��- 1 114 x 3/4° , 2.390 1.950 0,395 0.565 , 2,130 ,1 1 1/2 x 1 114" 2.680 2.390 0-425 11455 2250 Al-J 1 1/2 x l' 2.680 2.390 0.425 0.545 2.250 2 x 1 1/2' 3.280 2.680 0.410 0.460 2.320 2 x 1 114' 3.280 2.390 0.445 0,525 2.390 2 x 1" 3.280 1.950 , 0.410 0.580 2.320 2 x 314" 3.280 1.630 0.410 0.660 2.320 2 x 1/2" 3.280 1.630 0.410 0.730 2.320 2 112 x 2" 3.860 3.280 0.395 0.565 2,630 2 112 x 1 112" 3.660 3.280 , 0.395 0.615 2.630 , L______j 3 x 2' 4.620 3.280 0.460 0.690 2.880 3 x 1 112' 4.620 3280 0.460 0,740 2.880 37 , CAST IRON PIPE CAPS F l + — E 30 ® Outside Height♦' Thread Diameter Height -t.th Amin 8 i 18¢0 1810 0.920 3" 1 t 4 4- 1.90 0980 ..1 . � � -{ 8 4" 5.790 r.. ` .080 tr4, o - .,rasa 1 L._. ,,,44-.;-0......,.... CAST IRON CROSS A A FIGUR - 30A r-D--i , ,lit R Center Outside Length Metal Take Out NPS to End Dia.Band of T .d Thickness Dimension A B(min) ' min) E 112- 1.250 1.340 0A30 0.160 0.820 3(4" 1.440 1.--+ 0.500 0.180 0.940 1" 1.630 .950 0.580 0.200 1.050 1114' 1.9•1,41 2,390 0.670 0,220 1.270 1112` ` 30 2.680 0.700 0.240 1.430 2" 2.500 3,280 L750 0.260 1.750 I 38 Quality ap£e, Quality rPrad-ucts.. .sirace 1924 PRODUCTS FROM WARD MANUFACTURING WARD MANUFACTURING PRODUCTS ARE DISTRIBUTED BY: Class 150 Malleable Fittings Class 300 Malleable Fittings Cast Iron Fittings Class 125 Cast Iron Flanged Fittings Drainage Fittings Class 150 Unions Class 250 Unions Class 300 Unions Di-Electric Unions Class 300 Brass to Brass Seat Unions Top Beam and C-Clamps TEELOXTM,WARDLOXTM Fittings for Plain End Pipe COUPLOXTM Fittings for Grooved-End Piping System WARDFLEXTm Corrugated Stainles -- • System for Natural Gas and LPG Gray, Malleable and Ductile Iron Custom Castings 61006 WARD MANILFACTURING BLOSSBURG, PENNSYLVANIA 16912 PHONE (570) 630-2131 FAX (570) 638-3410 www. wardmfg . com For a complete listing of sales offices please visit our website listed above . .' .I\ f - • - i I I\ :I1 FireLock® Fittings tSEp� PL.i CsP See Victaulie publication 10.01 for details FireLock®products comprise a unique system specifically designed for fire protection services.FireLock full-flow elbows and tees feature CAD-developed,hydrodynamic design,affording a shorter center-to-end dimension than standard fittings.A noticeable bulge allows the water to make a smoother turn to maintain similar flow characteristics as standard full flow fittings. FireLock fittings are designed for use exclusively with Victaulic IPS-sized couplings that have been Listed or Approved for Fire Protection Services.Use of other couplings or flange adapters may result in bolt pad interference. Victaulic FireLock fittings pressure ratings conform to the ratings of Victaulic FireLock EZ® Style 009N/Style 009H couplings. MATERIAL SPECIFICATIONS Fitting:Ductile iron conforming to ASTM A-536,grade 65-45-12. Fitting Coating: • Orange enamel. • Red Enamel in EMEA-I. • Optional:Hot dipped galvanized. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCt.SUIi(. REV_K 10.03_1 IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 1 0.03 FireLock® Fittings DIMENSIONS k-CtoE C b I' to r'I p cmE .. o tr TAE ®r I o NO.001 NO.003 NO.002 NO,006 No.001 No.003 No 002 Na.006 Size 90 Elbow 45 E boa: Straight Tee Cap Nominal ' Actual i Approx. I APpmx. I Approx. Approx. Size i Outside Diameter I C to E ' Weight Each 1 C to E Weight Each C to E i Weight Each ' Thickness"T" Weight Each Inches Inches 1 Inches Lbs. Inches Lbs. Inches Lbs. Inches Lbs. mm mm mm kg mm kg mm kg rant kg 11/4 1660 0.8- _ 0.3 32 42.4 - - - _.. 21 0.1 115 1900 - '.. - - - 082 0.4 40 48.3 - - - - - - 21 02 2 2.375 275 1.7 2.00 1.8 2.75 2.4 0.88 0.6 SO 60.3 70 0.8 51 0.8 70 1.1 22 0.3 21/2 2.8/5 3.00 3.1 2.25 '. 2.2 3.00 3.6 0.88 1.0 65 73.0 76 1.4 57 1.0 76 1.6 22 0.5 76.1 mm 3000 3.00 3.30 2.25 2.4 - - -• 76.1 76 1.5 57 1.1 3 3.500 3.38 40 2.50 3.1 3.38 5.3 0.88 1.2 80 88.9 86 1.8 64 1.4 86 2.4 22 0.5 108rcm 4.250 4.00 5.7 3.00 5.1 4.00 7.5 - 1080 102 2.6 70 2.3 102 34 4 4.500 4.00 6.7 300 5.6 4.00 8.7 1.00 2.4 100 114.3 102 30 76 2.5 102 3.9 25 11 5 5.563 4.88 12.6 3.25 8.3 488 15.7 1.00 41 ....,... 125 141.3 124 5.7 83 38.... 124 __.7.1 25... 1.9 __- 159 mm 6.250 5.50 12.6 3.50 92 5.50 17.9 158.8 140 5.7 89 4.2 140 _. . 80 _._. 6 6.625 5.50 18.3 3.50 11.7 5.50 22.7 1.00 5.9 150 168.3 140 8.3 89 5.3 140 103 25 2.7 8 8.625 6.81 )5.5 4.25 20.4 6.94 38.7 1.13 12.7 • 200 219.1 173 11.6 108 9.3 176 • 17.6 29 • 5.8• •www.victaulic.com \ict9Ulie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03_2 REV_K • IPS CARBON STEEL PIPE-FIRE PROTECTION PRODUCTS 10.03 FireLock® Fittings FLOW DATA Size Equ value 3e_Umd.es o Slr odd Pine Actual No.002 Nominal Outside Elbows Straight Tee Size Diameter .____...._._...._......._________. Inches Inches No.001 1 No.003 mm mm 90"Elbow 45"Elbow Branch Run 1'd 1.660 - - 32 42.4 - - - - 115 1900 - - - 40 48.3 - - - 2 ...2375 3.5 I.8 85 3.5 50 60.3 1.1 0.5 2.6 1.1 212 2.875 4.3 2.2 108 43 • 65 730 1.3 07 3.3 13 76.1 mm 3.000 4.5 2.3 11.0 4.5 76.1 I4 0.7 34 1.4 .............. 3 . ...3.500 50 26 30 50 80 88.3 1.5 C.8 40 1.5 108 mm 4.250 6.4 3.2 '5.i 64 108.0 2.0 0.9 4.7 2.0 4 4.500 6.8 3.4 16.0 6.8 100 114.3 2.1 1.0 4.9 2,1 5 5.563 8.5 4.2 21.0 8.5 125 141.3 2.6 1.3 64 2.6 1590131 6.250 9.4 49 250 9.6 1588... 2.9 1.5 7.6 29 6 6.625 10.0 5.0 250 100 150 168.3 30 1.5 76 3.0 8 8.625 13 II 5.0 33.0 13.0 200 219.1 4.0 1.5 101 4.0 t The flow data listed is based upon the pressure drop of Schedule 40 pipe. www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIG COMPANY.C 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. rCta,,,,_ REV_K 10.03 3 IPS CARBON STEEL PIPE - FIRE PROTECTION PRODUCTS 1 0.03 FireLock® Fittings GENERAL NOTES NOTE When assembling FireLock EZ couplings onto end caps,take additional care to make certain the end cap is fully seated against the gasket end stop.For FireLock EZ Style 009N/009H couplings,use FireLock No.006 end caps containing the"EZ"marking on the inside face or No.60 end caps containing the"QV EZ"marking on the inside face.Non-Victaulic end cap products shall not be used with Style 009/009V/009H couplings. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 10.03 1539 REV K UPDATED 092012 .Cta U i c VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.03 FireLock® Rigid Coupling Style 005H ✓ctaulrc with Vic-Plus' Gasket System (North America and Asia Only) 10.02 Pk ft Material Specifications: I I �i Housing: Ductile iron conforming to ASTM A-536, grade t4$ �� 65-45-12. Ductile iron conforming to ASTM A-395, grade 65-45-15, is available upon special request. Patented Exaggerated for clarify Housing Coating:(specify choice) rnkiJS Standard: Orange enamel (North America); red Gasket System enamel (Europe) ❑ Optional: Hot dipped galvanized Approvals/Listings: UE O iLPCB Coupling Gasket: (specify choice) y fir® Fu VdS NOTE:Additional gasket styles are available.Contact Victaulic for details. 104-1a/02 See Victaulic Publication 10.01 for more details. ❑ Grade "E" EPDM Type A Vic-Plus"Gasket System' LPC and VdS Approved,see notes on page 3 EPDM(Violet color code). FireLock products have been Listed by Underwriters Laboratories Inc.and Approved by Factory Mutual Research for wet and dry(oil free air) Product Description: sprinkler services up to the rated working pressure using the ----------------- Grade"E"Type A Vic-Plus"'Gasket System,requiring no field FireLock Style 005H rigid coupling has a unique, lubrication for most installation conditions. patented angle-pad design which allows the housings ❑ Grade "L" silicone to offset while clamping the grooves. By permitting the housings to slide on the angled bolt pads, rigidity is Recommended for dry heat,air without hydrocarbons to obtained. +350°F and certain chemical services. Support and hanging requirements correspond to For dry services,Victaulic continues to recommend the NFPA 13 Sprinkler Systems. Angle-pad design permits use of Grade "E" Type A FlushSeal®Gasket. assembly by removing one nut/bolt and swinging the Contact Victaulic for details. housing over the gasket. This reduces components to handle during assembly. Bolts/Nuts: Heat-treated plated carbon steel,trackhead Style 005H FireLock coupling are designed and meeting the physical and chemical requirements of recommended for use ONLY on fire protection systems. ASTM A-449 and physical requirements of ASTM A-183. i Standard gasket and FlushSeal gasket approved for dry pipe systems to Vic-Plus" Gasket System: —40°F/-40°C.Based on"typical"pipe surface conditions,supplemental lubricant is recommended for services Installed below 0°F/-18°C and In North America and Asia,Victaulic offers a gasket for all dry pipe systems or systems to be subjected to air tests prior to system which requires no field lubrication on wet being filled with water.Supplemental lubrication may also be required on pipe systems that are hydrostatically tested. The pipe with raised or undercut weld seams or pipe that has voids and/or cracks at the weld seams.Victaulic continues to recommend the use of Vic-Plus System (patented) is dry, clean, and non-toxic. FlushSeal gaskets for dry services. It reduces assembly time substantially and eliminates the mess and chance of over-lubrication. Please refer to the latest copy of the Victaulic Field Installation Handbook (1-100)for supplemental lubrication requirements and dry pipe fire protection system notes. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date • victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 10.02 1538 Rev L Updated 06/2014 ®2014 Victaulic Company.All rights reserved. 1 victsulia victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Dimensions: ' Rated for wet and dry sprinkler systems at 350 psi/2413 kPa rrI _ ��� for 1 /-4'/32-100 mm sizes and 300 psi/2068 kPa for AL As./ I�i I 4'/.-8'/108-200 mm sizes;Schedule 10 roll grooved or M,A-ire ",� Schedule 40 cut or roll grooved steel pipe.Style 005H is rigid �� lrr and does not accommodate expansion,contraction or angular deflection. Actual Maximum Maximum Allow. Approx. Nominal Outside Working End Pipe End Dimensions Weight ', Size Diameter Pressure" Load' Separation2 Bolt/Nut3 X Y Z Each inches inches psi lbs. inches No.-size Inches inches inches lbs. I, mm mm kPa N mm inches mm mm mm kg ' 11/4 1.660 350 755 0.05 2.75 4.50 1.88 1.2 32 42.4 2413 3370 1.2 2-a3/4ax2Y` 70 114 48 0.5 11/2 1.900 350 990 0.05 3.00 4.75 1.88 1.2 40 48.3 2413 4415 1.2 2-3A x 2 1/4 76 121 48 0.5 2 2.375 350 1550 0.07 3.50 5.25 1.88 1.6 50 60.3 2413 6900 1.7 2-341 x 2'h 89 133 48 0.7 21/2 2.875 350 2270 0.07 4.00 5.75 1.88 1.9 65 73.0 2413 10110 1.7 2-r3/4ax2'h 102 146 48 .09 3.000 350 2475 0.07 4.13 5.75 1.88 1.9 76.1 mm_ 76.1 2413 11010 1.7 2-313x21/2 105 146 48 0.9 3 3.500 350 3365 0.07 4.63 6.13 1.88 2.1 80 88.9 2413 14985 1.7 2- x 21/2 118 156 48 1.0 4 4.500 350 5565 0.16 5.75 7.25 2.13 3.1 100 114.3 2413 24770 4.1 2-3i5 x 2 1/2 146 184 54 1.4 4.250 300 4255 0.16 5.63 7.25 2.13 3.1 108.0mm 108.0 2068 18940 4.1 2-'/e x 2'h 143 184 54 1.4 5 5.563 300 7290 0.16 6.88 9.00 2.13 4.5 125 141.3 2068 32445 4.1 2-16 x 3 175 229 54 2.0 5.250 300 6495 0.16 6.63 9.00 2.13 4.5 133.0mm 133.0 2068 28900 _ 4.1 2-'1/2zx2r3/4" 168 229 54 2.0 5.500 300 7125 0.16 6.88 9.00 2.13 4.8 139.7 mm 139.7 2068 31715 4.1 2-1/2x 23/4 175 229 54 22 6 6.625 300 10340 0.16 _ 8.00 10.00 2.13 5.0 150 168.3 2068 46020 4.1 2 Yz x 3 203 254 53 2.3 6.250 300 9200 0.16 7.63 10.00 2.13 5.5 159.0 m m 159.0 2068 40955 4.1 2-'h x 2'A 194 254 54 2.5 6.500 300 9955 0.16 8.15 10.00 2.13 5.5 165.1 mm 165.1 2068 44295 4.1 2-'h x 3 207 254 54 2.5 8 8.625 300 17525 0.19 2-313x410.50 13.14 2.63 11.3 200 219.1 2068 78000 4.8 '/" 267 334 67 5.1 1 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11 times the figures shown. 2 The allowable pipe separation dimension shown is for system layout purposes only.Style 005H couplings are considered rigid connections and will not • accommodate expansion or contraction of the piping system. 3 Number of bolts required equals number of housing segments.Metric thread size bolts are available(color coded gold)for all coupling sizes upon request. Contact Victaulic for details. 4 Style 005H couplings are VdS and LPC Approved to 16 Bar/235 psi. 10.02 1538 Rev L Updated 06/2014 C 2014 Victaulic Company.All rights reserved. victaulic.com 2 rctaulrc . victaulic.com I Couplings I Rigid I Style 005H I Publication 10.02 Listings/Approvals: The information provided below is based on the latest listing and approval data at the time of publication. Listings/Approvals are subject to change and/or additions by the approvals agencies. Contact Victaulic for performance on other pipe and the latest listings and approvals. --, Related Working Pressure Related Working Pressure Related Working Pressure psi • psi psi Pipe Size Pipe Size Pipe Size Sch. inches UL FM Sch. Inches UL ULC FM Sch. inches UL ULC FM 5 1'd-3 175 175 _ 175 EL 1.4-2 300 N/A N/A MT 1'/4-2 300 N/A N/A 11 -3 350 350 350 ET 1'/4-2 300 N/A N/A STF 114-4 N/A N/A 300 10,40 5-8 300 300 300 EZ 4-6 3006 N/A 300 Steady 11/4-2 N/A N/A 330 Thd BLT 1114-2 300 300 N/A FF 11/-4 N/A..._ N/A 300 TF 3-8 N/A N/A 300 DF 154—4 300 300 300 GAL-7 11/4-2 300 N/A N/A WLS 114-2 300 300 N/A DT 1'/4-2 300 300 N/A MLT 11/-2 300 N/A N/A XL 1A-3 300 300 i 300 EF 11/4-4 175' N/A 175 MF 11/4-4 300 N/A 300' 5 FM approved for service in 1 1/2-4'pipe. 6 UL Listed for service up to 4'pipe only. 7 UL Listed for service up to 3'only. 1 Installation Note Reference should always be made to the 1-100 Victaulic Field Installation Handbook Im This product shall be manufactured by Victaulic or to Victaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic^is a registered trademark of Victaulic Company. 10.02 1538 Rev L Updated 06/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 3 Nictalulic. Victaulic® Flexible Coupling ✓�taui,c Style 75 06.05 d M''• _ amm�o� ...',. a N: A WARNING - • Victaulic RX roll sets must be used when grooving light-wall/thin-wall stainless steel pipe for use with 1 \r J Victaulic Couplings. V Failure to use Victaulic RX roll sets when grooving ' light-wall/thin-wall stainless steel pipe may cause joint failure,resulting in serious personal injury and/or J Exaggerated for clarity property damage. Approvals/Listings ® &• LPCB ® le VdS NOTICE • Victaulic RX grooving rolls must be ordered See Victaulic publication 10.01 for details separately.They are identified by a silver color and See Victaulic publication 02.06 for portable water approvals if applicable. the designation RX on the front of the roll sets. Product Description Style 75 is available where moderate pressures are expected or weight considerations are a factor. Up to 50% lighter in weight than the Style 77,the Style 75 coupling is recommended for service up to 500 psi/3450 kPa depending on size. Housings are cast in two identical pieces in all sizes. Hot-dip galvanized and special coatings are available for all sizes. The Victaulic standard flexible coupling offering for grade "EHP" or "T" gaskets is the Style 177 installation-ready flexible coupling. For all available sizes,the Style 177 is the standard flexible coupling Victaulic supplies in North America for piping systems using Grade "EHP" or "T" gaskets. Contact Victaulic for further details. Performance data presented in this document is based on use with standard wall, carbon steel pipe. For use with stainless steel pipe, please reference publication 17.09 for pressure ratings and end loads.When used on light wall stainless steel pipe, the Victaulic RX roll set must be used to roll groove the pipe. For further information regarding roll grooving stainless steel, refer to publication 17.01. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 06.05 1470 Rev 0 Updated 09/2014 ®2014 Victaulic Company.All rights reserved. 1 ictauliC' victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 Material Specifications Housing: Bolts/Nuts: Ductile iron conforming to ASTM A-536,grade 65-45-12. Heat-treated plated carbon steel, trackhead meeting the Ductile iron conforming to ASTM A-395, grade 65-45-15, physical and chemical requirements of ASTM A-449 and is available upon special request. physical requirements of ASTM A-183 Housing Coating: (specify choice) ❑ Standard: Orange enamel. ❑ Optional: Hot dipped galvanized and others. Gasket: (specify choice') NOTE Additional gasket styles are available.Contact Victaulic for details. LI Grade"E"EPDM EPDM (Green stripe color code). Temperature range—30°F to+230°F/-34°C to+110°C. May be specified for cold and hot water service within the specified temperature range plus a variety of dilute acids, oil-free air and many chemical services. UL Classified in accordance with ANSI/NSF 61 for cold +73°F/+23°C and hot+180°F/+82°C potable water service and ANSI/NSF 372. NOT COMPATIBLE FOR PETROLEUM SERVICES. ❑ Grade "T"Nitrile Nitrile(Orange stripe color code). Temperature range 20°F to+180°F/29°C to+82°C. May be specified for petroleum products, air with oil vapors, vegetable and mineral oils within the specified temperature range. Not compatible for hot water services over +150°F/+66°C or for hot dry air over+140°F/+60°C. 1 Services listed are General Service Guidelines only.It should be noted that there are services for which these gaskets are not compatible.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service guidelines and for a listing of services which are not compatible. 06.05 1470 Rev 0 Updated 09/2014 0 2014 Victaulic Company.All rights reserved. victaulic.com 2 ictauliC victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 • Dimensions Style 75 �r:r i Y rr IF 11 :1 t■. I I 11111 Actual Maximum Maximum Allow. Dimensions Approx. Nominal Outside Working End Pipe End Deflection from Weight Size Diameter Pressure 2 Load' Separations Centerline' Bolt/Nut' X Y Z Each Pipe inches inches psi lbs. inches PerCplg. inches/ft. inches Inches inches lbs. mm mm kPa N mm Degrees mm/nn (No.)size inches mm mm mm kg 1 1.315 500 680 0-0.06 2�-43' 0.57 2-s%ax2 2.38 - 4.27 1.77 1.3 25 33.4 3450 3025 0-1.6 48 61 108 45 0.6 1 Y. 1.660 500 1080 0-0.06 2.-10 0.45 2.68 4.61 1.77 1.4 32 42.2 3450 4805 0-1.6 38 2-sh x 2 68 117 45 0.6 1 1 1.900 500 1420 0-0.06 1.-56' 0.40 5 2-2/a x 2 2.91 4.82 1.77 1 40 48.3 3450 6320 0-1.6 33 74 122 45 0.6 2 2.375 500 2215 0-0.06 , 0.32 3.43 5.22 1.88 1.7 50 60.3 3450 9860 0-1.6 1 -31 26 2-sh x 2 87 133 48 0.8 21 2.875 500 3245 0-0.06 0.26 3.88 5.68 1.88 1.9 65 73.0 3450 14440 0-1.6 1�-15 22 2-3/4 x 2 98 144 48 0.9 3.000 500 3535 0-0.06 0.26 4.00 5.90 1.88 1.9 76.1 mm 76.1 3450 15730 0-1.6 1�-12 22 2-35x2 102 150 48 0.9 3 3.500 500 4800 0-0.06 , 0.22 4.50 7.00 1.88 2.9 __ 80 88.9 3450 21360 0-1.6 1 -2 18 2 h x 2 14 114 178 48 1.3 31 4.000 500 6300 0-0.06 0.19 5.00 7.50 1.88 2.9 90 101.6 3450 28035 0-1.6 0"-54' 16 2-'h x 2 sit 127 191 48 1.3 4 4.500 500 7950 0-0.13 ,_ 0.34 s 5.80 8.03 2.13 4.1 100 114.3 3450 35380 0-3.2 1 36' 28 2-h x 2 b 147 204 54 1.9 108.0 mm 4.250 450 6380 0-0.13 1.-41' 0.35 2-12 x 70 5.55 7.79 2.13 3.7 108.0 3100 28395 0-3.2 29 141 198 54 1.7 41 5.000 450 8820 0-0.13 0.25 6.13 9.43 2.13 5.5 120 127.0 3100 39250 0-3.2 1°-26' 21 2-s/a x 3'/4 156 240 54 25 5 5.563 450 10935 0-0.13 0.27 6.88 10.07 2.13 5.8 125 1413 3100 48660 0-3.2 1.-18' 23 2-sie x 3 r/' 175 256 54 2.6 133.0 mm 5.250 450 9735 0-0.13 1^-21, 0.28 2-1 fi x 82.5 6.55 9.37 2.13 6.0 133.0 3100 43325 0-3.2 24 166 238 54 2.7 5.500 450 10665 0-0.13 0.28 6.80 9.59 2.13 6.3 139.7 mm 139.7 3100 47460 0-3.2 1 x-18 24 2-3'°x 3/` 173 244 54 2.9 6.000 450 12735 0-0.13 0.21 7.38 10.48 1.88 . 6.2 152.4 mm 152.4 3100 56670 0-3.2 1.-12' 18 2-iS x 3 V` 187 266 48 2.8 6 6.625 450 15525 0-0.13 0.23 8.00 11.07 2.13 7.0 150 ___168.3 3100 69085 0-3.2 1 -5' 18 2-544x3 Y< 203 281 54 3.2 6.250 450 13800 0-0.13 0.24 7.63 10.49 2.13 6.8 159.0 mm 159.0 3100 61405 0-3.2 1°-9' 20 2-16 x 62.5 194 266 54 3.1 8 8.625 450 26280 0-0.13 00_50, 0.18 2-1.x 4 Y. 10.34 13.97 2.13 12.4 200 219.1 3100 116945 0-3.2 14 263 355 59 5.6 2 Working Pressure and End Load are total,from all internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe. 3 Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe. Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by: 50%for 3/4,-3 1/2"/20-90 mm;25%for 4"1100 mm and larger. 4 Number of bolts required equals number of housing segments. General Notes Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11/2 times the figures shown. 06.05 1470 Rev 0 Updated 09/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 3 ictauli6' • victaulic.com I Couplings I Flexible I Style 75 I Publication 06.05 • Installation Note Reference should always he made to the 1-100 Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Viclaulic specifications.All products the product you are installing.Handbooks are Included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete Installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Viclaulic°is a registered trademark of Viclaulic Company. 06.05 1470 Rev 0 Updated 09/2014 ®2014 Victaulic Company.All rights reserved. victaulic.com 4 ✓ctaulic' CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 .0., o 0. Reducing Coupling w �" > SEE VICTAULIC PUBLICATION 10.01 FOR DETAILS STYLE 750 The Style 750 Reducing Coupling permits direct reduction on the piping run.Designed , ) to replace two couplings and a reducing fitting,the Style 750 features a special reducing gasket for pressure responsive sealing.A steel washer which prevents telescoping of the smaller pipe inside the larger pipe during vertical systems assembly is available upon request. 4 1\0 ,1 IIk• MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. Housing Coating:Orange enamel • Optional: Hot dipped galvanized and others Gasket:(Specify choice*): • Grade"E"EPDM(All other sizes) EPDM(Green color code).Temperature range-30°F to+230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services.UL classified in accordance with ANSI/NSF 61 for cold+86°F/+30°C and hot+180°FI+82°C potable water service.NOT RECOMMENDED FOR PETROLEUM SERVICES. • Grade`T"nitrile Nitrile(Orange color code).Temperature range-20°F to+180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range.Not recommended for hot water services over+150°F/+66°C or for hot dry air over+140°F/+60°C. . Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. • Optional:Assembly Washer:Galvanized,carbon steel Bolts/Nuts:Heat-treated plated carbon steel,trackhead meeting the physical and chemical requirements of ASTM A-449 and physical requirements of ASTM A-183. JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. r Ctd U�I C' REV-I • CARBON STEEL PIPE-GROOVED COUPLINGS 06.08 Reducing Coupling STYLE 750 ~ DIMENSIONS Max.Work Allow-Plpe Bolt/Nnta Appro,. Size I Piessure' ' Max.End Load' End Sep.1 Deflect.Fr.Grr No Sire Dimensions-Incheslmm Wet.Each Nominal Per Pipe : l Size psi l.bs, Cole. 112/M. l Lbs. Inches/mm kPa N Inches/mm Deg. rrm/nr 1 Inches X Y 2 kg 2 I 350 r 500 0-0.07 i 0.20 3.38 - 5.28 188 2.7 x 0°-57' 2-3/8x2 50 25..... 2410 2225 0-1 R 17 j 85 134 48 1.2 11/2 350 1000 7 007 0.20 3.88 528 188 2.0 40 2410 4450 0-1.8 0°-5T 17 2-3,B x 2 85 134 48 ' 1.0 21/2 7 500 2215 0-0.07 016 400 893 188 3.1 X 0°-47 2-3/8x2 65 50 3450 9850 0-1.8 14 102 151... 48 IA _.. 76.1 men x 2 350 1550 0-0.07 0.16 4.38 6.63 1.88 4.6 0°-47 ' 2-r16x714 50 2410 6900 0-1.8 14 111 168 48 2°I 3 x 2 350 1550 0-0.07 0.-g9, 0.13 I.. 2-15x2;; 475 7.13 1.88 4.9 80 50 2410 6900 0-1 8 11 121 181 48 2.2 2 n 500 3250 0-007 0.13 4.75 7.13 1.88 . 4.3 0'-39' 2-1/2 x 2'4 121 181 48 2.0 65 3450 14460 0-1 B 11 350 24/5 0-0,07 013 4.75 7,13 1.88 4.2 889 mm x 761 men 2410 11010. 0-1.8 0'-39 11 2-rh x274 125 181 48 1.9 4 2 350 1550 0-0.13 0.28 6.25 8.90 2.25 8.1 100 x 50 2410 6900 0-3.2 t°-1)' 25 2-5/8x 3% 139 226 57 3.7 21/2 65 350 2275 0-0.13 1• 19, 0.28 1 2-5/Sx 3'in 6.25 226 225 86 65 2410 10125 0-3.2 25 159 226 57 3.9 3 500 i 4810 G-3.13 0.28 6.00 890 775 6./ 80 3450 21400 0 3.2 25 2-5/8 z 3%a 152 226 57 3 0 350 2475 3-013 0.28 1143mm x 761mm 24'0 11014 1°-19' 0-3.7 2-5/.e0,r 159 8.90 225 69 25 159 226 57 3.1 5 4 350 5555 0-013 1 0.22 2- 7.18 1070 2.13 11.2 125 x 100 2410 24765 0-3.2 -3 I 19 y.x4Y, 182 272 54 5.1 5 4 350 5565 0-0.13 0.18 8.63 1190 225 16.7 0°-52' 2-94e4/� 150 100 _ 2410 24765 0-3.2 15 181 302 57 7 6 5 350 j 8500 0-0.13 0:18 8.31 11.90 225 129 125 2410 37825 0 0 -52' 2-14x4A - 3.2 15 211 302 57 5.9 165.1 nrrn x 4 350 5565 0 0.13 0'-55' 0'19 2-3:x4r/ 863 11.90 2.25 15.2 100 2410 24765 0-32 16 219 302 57 69 8 6 350 12060 0-0.13 0,13 -... - 1081 14.88 2.50 224 200 x 150 2410 53645 0-3.2 0 38 11 2-7/8 x 5 275 378 64 10 2 2191 mm on 165.1 mm 350 11610 . G-0.13 0.13 //05x5 1075 1488 750 2"+2 2 0°-38 2410 � 51645 0 32 11 2/3 378 64 105 10 8 350 20450 0-0.13 0.9 13.12 17.26 262 314 273 x 219.1 2410 90970 0-3.2 0"-25' 8 2-1 x5rk 333 438 67 14.2 Style 750 Reducing couplings should not be used with end caps(#60)in systems where a vacuum may be developed.Contact Victaulic for details. *Working Pressure and End Load are total,from all Internal and external loads,based on standard weight(ANSI)steel pipe,standard roll or cut grooved in accordance with Victaulic specifications.Contact Victaulic for performance on other pipe.Maximum working pressure rating based on larger pipe size. Maximum End Load rating based on smaller pipe size.WARNING:FOR ONE TIME FIELD TEST ONLY,the Maximum Joint Working Pressure may be increased to 11 times the figures shown. t Allowable Pipe End Separation and Deflection figures show the maximum nominal range of movement available at each joint for standard roll grooved pipe.Figures for standard cut grooved pipe may be doubled.These figures are maximums;for design and installation purposes these figures should be reduced by:50%for y-31720-90 mm;25%for 47100 mm and larger @ Number of bolts required equals number of housing segments. Metric thread size bolts are available(color coded gold)for all coupling sizes upon request.Contact Victaulic for details. WARNING:Depressurize and drain the piping system before attempting to install,remove,or adjust any Victaulic piping products. Y 14-Z1 Y N-Z-s A 111 LE Ili *lir II in www.victaulic.com jat9Udie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.C 2012 VICTAULIC COMPANY ALL RIGHTS RESERVED. 06.08_2 REV_J CARBON STEEL PIPE-GROOVED COUPLINGS 06.0E4 Reducing Coupling STYLE 750 • FLOW DATA HEAD LOSS The head loss across Style 750 Reducing coupling is very small and is essentially the same as for standard short body reducing pipe fittings. Equivalent lengths of standard weight steel pipe are shown in the tables.All data is based on water flowing at ambient temperature. FLOW REDUCING FLOW EXPANDING Equiv.Pipe Equiv.Plpz Size Lcnglh Size Length Nominal I Nominal Size Sm.Din. Size Sm.Dia. Inches/mm Feel/m Inches/mm Feeler 2 1 5.9 1 2 2.7 50 x 25 1.8 25 x 50 0.8 11/2 2.0 1,' x 1.9 40 0.6 e0 50 0.6 2'h x 2 1.9 2 21/2 1.0 ... 65 50 0.6 50 x 65 0.3 76.1 mm x 1 1.9 761 rnm 1.0 50 0.6 0.3 3 2 l 5.5 3 3.5 80 x 50 17 80 1.1 2/: 3.8 4 3.0 65 12 100 0.9 88 9111M x 761 mm . 18 .... g9i x 80 OS 4 7 60.._ 4 30 _... I00 x 50 1.8 100 0.9 65 6 8 76.1 mm x 88.9 moo 08 80 1.8 1143mm 09 114.3mm x 76.1mm 1.8 O x 100 0.8 4 3.0 4 5 3.3 125 x 100 I 09 100 x 125 1.0 6 4 6.0 _.... 6 4.6 15C x 100 ' 1.8 150 1.4 5 4.5 165.1 mm 4.6 125 1.4 1.4 4 6.0 S 6 2.3 165.1 mm x 100 1.8 125 x 150 0.7 6 6_..... 73 _... 6 8 6.0 200 x 150 2.2 150 x 200 1.8 219Im m m x 1651m 2.23 165.1 mm x 219.1 mm ...1555 10 8 I 8.7 8 10 6.3 273 x 219.1 2.65 219.1 x 273 19.2 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.O 2012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. r.ta UI•C REV 1 00.OS_3 CARBON STEEL PIPE—GROOVED COUPLINGS 06,08 Reducing Coupling STYLE 750 INSTALLATION Reference should always be made to the 1-100 Victaulic Field Installation Handbook for the product you are installing. Handbooks are included with each shipment of Victaulic products for complete installation and assembly data,and are available in PDF format on our website at www.victaulic.com. WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. • NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. For complete contact information,visit www.victaulic.com 06.08 1536 REV J UPDATED 08/2012 ictaulic' VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02012 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 06.08 IPS CARBON STEEL.PIPE FIRE PROTECTION PRODUCTS 10.21 Vic®-End II End of Run Fitting (1) .C> 1115 SEE VICTAULIC PUBLICATION 18.01 FOR DETAILS SERIES 67 The No.67,Vic®-End II,End of Run Fitting is the fast,easy,economical way to end a branch line.The fitting installs easily with standard FireLock®couplings and allows direct head connection,sprigs or drops. Available in 1'A,1'/z,2 and 21132-65mm sizes,the fittings can he supplied with l/,3e,or 1115,20 or 25mm female threaded(NPT)outlet(BSPT option available). The 90°reducing outlet fitting is UL/ULC Listed and FM Approved for a maximum rated working pressure of 500 psi/3450 kPa. MATERIAL SPECIFICATIONS Housing:Ductile iron conforming to ASTM A-536,grade 65-45-12,painted Orange Enamel.Ductile iron conforming to ASTM A-395,grade 65-45-15,is available upon special request. •Optional:Galvanized-hot dipped. Outlet:NPT •Optional:BSPT DIMENSIONS,PERFORMANCE Nominal Size C to E Approx.Weight Ea Equivalent Inches/mm Inches/mm Lbs./Kg Feet/meters of pipe 1'h 5 '65 NOT I 238 14 2.b 32 15NPT ' 61 06 09 , f5NPT _ 2.38 I4 2 li 20NPT 61 06 09 1 NPT 238 14 28 25 NPT 61 06 0.9 I'G x Y NOT ',. 250 1 6 2.9 40 15 NPT 64 0.7 0.9 44 NPT ''' 2.50 1 6 2 9 20NPT 64 .....0.7 ___._....... I NPT 250 1.6 29 25 NOT 64 07 0.9 2 5 1/2 NPT 2.75 1 7 4.0 50 15 NPT 70 0.8 1 2 44'APT 273 1.7 40 20 NPT 70 0£ 1.2 1 N'T 2.75 1./ 40 25 NPT /0 0£ 1 21/2 x 5 NOT 3.00 ,, 2D 57 65 15 NPT 76 0.9 1 7 //4 NPT 3.00 2.0 S.7 20 NPT 76 0.9 1.7 1 NPT 3.00 2.0 5.7 25 NPT 76 09 1.7 JOB/OWNER CONTRACTOR ENGINEER System No. _ Submitted By __- Spec Sect _Pa-a Location Date Approved Date www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.Cr 2007 VICTAULIC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA .Ct9UIid REVD 10.21_,1 1 Vic®-End II End of Run Fitting SERIES 67 • WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. • WARNING A A WARNI er • This product must be installed by an experienced,trained installer, in accordance with the instructions provided with each valve.These instructions contain important information. Failure to follow these instructions may result in serious personal injury, - property damage,or valve leakage. If you need additional copies of this product literature or the valve installation instructions,or if you have any questions about the safe installation and use of this device,contact Victaulic Company,P.O. Box 31, Easton, PA 18044-0031 USA,Telephone:001-610-559-3300. 1111111111111111111111 111111111111131 WCAS-7GNF4Y For complete contact information,visit www.victaulic.com 10.21 3209 REV D UPDATED 7/2009 j ,imuIi VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02007 VICTAUUC COMPANY.ALL RIGHTS RESERVED.PRINTED IN THE USA 10.21 • stariM Fire Products Division of Anvil '.' International 44" • .. , i rE-.--•.."......r:' - /......, _ , * se, 1‘..-,-,,,,,,---,, 4 • a — 1 , , ,-7: v--: , _ f' '4 ' ,.. ' ..‘11/ '"!:' ',',. '-'!""'- .' •".1.°,7:."7.ii7A4j.:-, .,......, ' stv 4,44_, i• .4 ,.:.4.4,4,44,.. 444 4 41 - 470.-- www. anvjlstar. com i:'i..... .,i' . • .,. -4-.,,,,,i, I, ..,, ,,..-- -,,-: ' MERIT, r:,...).1i,:i-ii,f_,,j-, _:_;15_5.27.,r• j_. ; for it Protection Weld-MiserTM Tee-Let® Welding Outlet Fittings i Unified DesignTM Series Merit's Unified Design Series carries all important design considerations into its entire line of welding branch outlet fittings tn��a Merit®Weld-Miser.""Tee-Lets®are designed and Manufactured to reduce the amount of weld required to install the Tee-Lets , "r on thin wall or proprietary flow pipe.Typically only one weld-pass completes the installation.Merit Tee-Lets install with less weld volume than any other brand of welding outlet fittings for fire sprinkler applications.To accomplish this: _ _ •The contoured end of the fittings employs a reduced outside diameter. Two major advantages are immediately apparent: •The thinner wall on the contoured end permits welding temperatures to be matched to the thickness of the branch line or � main thereby insuring complete penetration without cold welds,weld roll-off, burn-through or excessive distortion. •On smaller sizes a heavier section is maintained on the threaded end of the fitting.This protects the threads from damage during shipping and handling prior to installation as well as from weld distortion. •Each outlet size 11/2 and larger,whether male or female threaded,cut grooved or beveled requires the same hole size in the header pipe.This simplifies the installation process. General Specifications •Tee-Let welding outlet fittings are manufactured from highly weldable steel which conforms to the chemical and physical requirements of ASTM A-53,Grades A or B,Type E.Ease of Installation is assured when automatic welding equipment is used to install Merit Tee-Lets. •Threads are cut in accordance with the requirements of ANSI B1.20.1,national standard for tapered pipe threads,or ISO-7-1 threads are available. •Tee-Let threaded and grooved welding outlet fittings are UUULO Listed and FM Approved for use in the fire sprinkler systems installed in accordance with the requirements of NFPA Bulletin 13.They are rated for 300 PSI operation in fire sprinkler systems,and higher pressures in other non-critical piping systems. • •Tee-Lets are offered in a wide variety of header sizes.The consolidated header sizes shown in the following charts allow the fittings to be installed on more than one header size, permitting the first size listed to fit the header perfectly,while a small gap along the longitudinal center line of the header will appear for the second size listed. •Merit®Weld-Miser Tee-Lets®are identified by a lot number that provides full traceability per ISO 9000 specifications. For Your Piping Systems Specify Weld-MiserTM Tee-Let® Branch Outlet Fittings shall be Merit Weld-Miser Tee-Let, Lightweight forged steel,employing low weld volume profile to provide for full penetration welds with minimum burn through and pipe distortion on Schedule 5 thru 10,proprietary thin wall,and standard wall pipe.Threads are to be ANSI 81.20.1,or ISO-7-1,and the bore of the fittings calculated to improve flow.Welding outlets to be UL Listed, FM Approved for use conforming to NFPA,Bulletin 13 and pressure rated for 300 PSI maximum. How to Order - Use either of the following methods for ordering Merit®Weld-MiserTM Tee-Let®. Method No. 1 Method No.2 Specify quantity desired followed by the part Use the following system: number shown in the"dimensions"chart for the type and size of outlet desired. Type Merit Steel Quantity Part Number Quantity Outlet Size Header Size Weight End Tee-Let Material Always Column"A" Insert size Sch.10 A-Female Thread order a few of Chart consolidation Standard B-Male Thread more than from Column C-Cut Groove actually "B"of chart. C/R-Roll Groove required for the job. _2- ArgviLStar° Fir©Products Division 111111111111111111111.11= 44.6. MERIT Weld-Miser TM Tee-Let® Welding Outlet Fittings For Fire Protection & Other Low Pressure Piping Systems Merit Weld-MiserTm Tee-Let®Welding Branch Outlet Fittings offer the user a high strength,low cost forged threaded and grooved line of fittings spe- cifically designed and manufactured to be installed on Schedules 5 thru 10,proprietary thin wall flow pipe and standard wall pipe. Merit Tee-Lets are forged steel welding outlet fittings.The material used in manufacture meets the chemical and physical requirements of ASTM A 53, Grades A or B,Type E,A-135,A-795,Tee-Lets employ a low weld volume avivi design to provide for either a partial or full penetration weld employing a single pass with minimum burn-through and pipe distortion. Weld Miser Tee-Lets are recommended for use on proprietary thin wall,Schedules 5, 10 and 40 pipe.Threads comply with ANSI B1.20.1 or IS07/1.They are UL Listed and FM Approved for use conforming to the requirements of Bulletin 131999 of the National Fire Protection Association.When used in fire sprinkler systems,Tee-Lets are rated for 300 psi.When used in mechanical systems, maximum pressures are calculated using criteria de- veloped for ASME B31 piping code. ()it.° ►/ APPROVED For Ilatlng/ayproVal halls contact your AnvIIStar'Represeolallve. TEE-LET WELDED OUTLET FITTING (UL UIZU—EX6032, FM APPROVAL GUIDE CHAPTER 1 —PIPE FITTINGS) Outlet Model Outlet Pipe Size Header Pipe Size Rated Pressure (Inch) (Inch) (psig) 12,4'4,1 12.8(Sch.10,40) Tee-Let Type A 11/4,112,2.212,3,4 12-4(Sch.5,DynaFlow) 300 (F-Threaded End) 2 4(EZ-Flow) 2,4 6(EZ-Flow) Tee-Let Type C 11/4-8 11/4-8(Sch.10,40) (Grooved End) 300 212-8 1h-4(Sch.5,DynaFlow) Tee-Let Type C/R 11/4-6 11/4-8(AU Schedules) 300 (Roll Grooved End) 1)Size-on-size(i.e.2 x 2)Tee-Lets are not FM Approved. 2)FM rated working pressure when welded on Sch.5 or non-threadable lightwall pipe is 175 psi. A Star- _3 Fire Products Division SN Air MERIT r,= . �r-- rswx Weld-Miser TM Tee-Let® iv Welding Outlet Fittings A Type Female Thread 1: c M4- I 4 y WELD-MISERTM TEE-LEe DIMENSIONS & PART NUMBERS WELI-MISERTM TEE-LET DIMENSIONS & PAR'NUMBERS Part Nominal Nominal Outlet Inside Make Weight pad Nominal Nominal Outlet Inside Make Weight Number Outlet Header Length Diameter Up Each Number Outlet Header Length Diameter Up Each A B C D M A B C 0 M NPT(BSPT) In(mm) In(mm) In(mm) In(mm) In(mm) Lb.(kg) NPT(BPI) In(mm) In(mm) In(mm) In(mm) In(mm) Lb.(kg) 1002002 1/4 x 11/4-8 0.080 1020020 2 1.750 2.067 0.875 0.857 - 6 z 6-200 0 04 1120020 50 44.5 52.5 22.2 0.38 1005012 11/4-11 1.063 0.700 0.500 0.171 1020025 21/2 1.750 2.067 0.875 0.829 32-40 27.0 17.8 12.7 0.08 1120025 65 44.5 52.5 22 2 0.38 1005015 11 -2 1.063 0.700 0.500 0.171 1020030 3 1.750 2.067 0.875 0.829 - 1h x 40-50 27.0 17.8 12.7 0.08 1120030 60 44.5 525 222 0.39 1005020 13 x 2-21/2 1.063 0.700 0.500 0.171 1020040 2 x 4 1.750 2.067 0.875 0.800 - 50-65 27-0 17.8 12,7 0.08 1005025 21 -8 1.063 0.700 0.500 0.169 1120040 50x 100 44.5 52.5 22.2 0.36 - 65-200 , 27.0 17.8 12.7 0.08 1020050 5 1.750 2.067 0.875 0.743 1007012 11/4-11/2 1.125 0.900 0.500 0.260 1120050 125 44.5 52.5 22.2 0.34 - 32.40 28.6 22.9 12.7 0.12 1020060 6 1.750 2.067 0.875 0.743 1007015 11/2.2 1.125 0.900 0.500 0.260 1120060 150 44.5 52.5 22.2 0.34 - 4'4x 40-50 28.6 22.9 12.7 0.12 1020080 8 1.750 2.067 0.875 0.743 1007020 19 x 2-21 1.125 0.900 0.500 0.260 7123080 200 44.5 52.5 22.2 0.34 50-65 26.6 229 12.7 0.12 1025025 21/2 2.215 2.469 1.125 1.250 10070- 25 21 -8 1.125 0.900 0.500 0.256 7125025 65 54.0 62.7 28.6 0.55 _ 65.200 28.6 22.9 12.7 0.12 - 1025030 3 2-215 2.469 1.125 1.200 10100- 12 11/4-11 1.250 1.145 0.500 0.331 1125030 80 54.0 627 gas U 5 1110012 32-40 312 29,1 12.7 0.15 1010015 11/2-2 1.250 1.145 0.500 0.331 1025040 4 2.215 2.469 1125 1.150 1770015 40-50 31.8 29.7 12.7 015 1125040 21/2x 100 540 62.7 28.6 052 1010020 2-21 1.250 1.145 0.500 0.320 1025050 65x 5 2.215 2.469 1.125 1.150 1110020 1 x 50-65 31.8 29.1 12.7 0 11 1125050 125 54.0 62.7 28.6 0.52 1010025 25 21 -3 1.250 1.145 0.500 0.314 1025060 6 2.215 2.469 1.125 1.150 1110025 65-80 31.8 29.1 12.7 0.14 1125060 150 54.0 62.7 28.6 0.52 1010030 3-4 1.250 1.145 0.500 0.309 1025080 8 2.215 2.469 1125 1.150 1110030 80-100 31.8 29.1 127 014 1125080 200 54.0 62.7 28.6 0.52 1010050 5-8 1.250 1.145 0.500 0.291 I 1030030 3 2.500 3.068 1.500 1.750 1110050 125-200 31.8 29.1 12.7 0.13 - 80 63.5 77.9 38.1 0.79 1012012 11/4-11/2 1.375 1.490 0.500 0.432 1030040 4 2.500 3.068 1.500 1.700 1112012 32-40 34.9 37.8 12.7 .019 - 100 635 77.9 38.1 0.77 1012015 11/2-2 1.375 1.490 0.500 0.421 1030050 3 x 5 2.500 3.068 1.500 1.700 1112015 40-50 34.9 37.8 12.7 .019 - 80 x 125 63.5 77.9 38.1 0.77 1012020 2-21 1.375 1.490 0.500 0.421 1030060 6 2.500 3.068 1.500 1.650 1112020 11/4 x 59-65 34.9 37.8 12.7 .019 - 150 63.5 77.9 38.1 0.75 1012025 32 x 21 -3 1.375 1.490 0.500 0.411 1030080 8 2.500 3.068 1.500 1.650 1112025 65-80 34.9 37.8 12.7 .019 - 200 63.5 77.9 38.1 0 75 1012030 3-4 1.375 1.490 0.500 0.389 1040040 4 3.000 4.026 2.000 3.000 1112030 80-100 34.9 37.8 12.7 .018 - 100 762 1023 50.8 116 1012050 5-8 1.375 1.490 0.500 0.389 1040050 5 3.000 4.026 2.000 2.900 1112050 125-200 34.9 37.8 12.7 ,018 4 x 125 76.2 102.3 50.8 1.32 1015015 11h 1.625 1.610 0.875 0.477 1040060 t03 A 6 3.000 4.026 2.000 2.800 1715015 40 41.3 40.9 22.2 .022 1015020 2 1.625 1.610 0.875 0.477 - 050 76.2 102.3 50.8 1.27 1115020 50 41.3 409 22.2 .022 1040080 8 3.000 4.026 2.000 2.800 1015025 11 x 21/2 1.625 1.610 0.875 0.477 - 200 - 76.2 102.3 50.8 1.27 1115025 40 x 65 41.3 40.9 22.2 .022 1015030 3-4 1.625 1.610 0.875 0.477 Note: 7115030 80-100 41.3 40.9 22.2 .022 Part#1002002 is not UL Listed or FM Approved. 1015040 - 4 1.625 1.610 0.875 0.477 All size-on-size(i.e.2 x 2)Tee-Lets are not FM Approved. 1115040 100 41.3 - 40.9 22.2 .022 1015050 5-8 1.625 1.610 0.875 0.477 1115050 _ 125-200 _ 41.3 40.9 22.2 .022 _4 ANV i Star- Fire Products Division ,05177:444.4%1, • • _ fnAIAn MERIT Male Thread Cut Groove Weld-Miser-11A Tee-Let° Standard Weight Standard Weight Welding Outlet Fittings I< - E -A I<- E �_ A i ■ Ar j ; '/, I --1.- <- F <- F,if -I s I WELD-MISERTM TEE-LET` - DIMENSIONS (NOMINAL SIZES 1"THRU 2°) Outlet Male Thread °t Nominal Outlet Nominal Header Inside Diameter Outside Diameter Wall Thickness Std.Wt. Sid.Wt- A B LenCplh D E F NPT(ASPT) NPT(BSPT) In.(mm) In.(mm) In.(mm) I In.(mm) I In.(mm) In.(mm) 1310012 2010012 11/4-11 3 1.049 1.315 0.133 32-40 80 266 33.4 3.4 1310015 2010015 11/2-2 3 1.049 1.315 0.133 40-50 80 26.6 33.4 3.4 1310020 2010020 lx 2-2½ 3 1.049 1.315 0.133 25x 50-65 80 26,6 33.4 3.4 1310025 2010025 21 -4 3 1.049 1.315 0.133 65-100 80 26 6 33.4 3.4 1310050 2010050 5-8 3 1.049 1.315 0.133 125-200 80 26.6 33.4 3.4 1312012 2012012 11/4 3 1.368 1.660 0.140 32 80 34.7 42.2 3.6 1312015 2012015 11 3 1.368 1.660 0.140 40 80 34.7 42.2 3.6 1312020 2012020 13/4 x 2-21/2 3 1.368 1.660 0.140 32x 50-65 80 34.7 42.2 3.6 1312025 2012025 3-4 3 1.368 1.660 0.140 80-100 80 34.7 42.2 3.6 1312050 2012050 5-8 3 1.368 1.660 0.140 125-200 80 34.7 42.2 3.6 1315015 2015015 11/2 3 1.610 1.900 0.145 40 80 40.9 48.3 3.7 1315020 2015020 2 3 1.610 1.900 0.145 50 80 40.9 48.3 3.7 1315025 2015025 11 x 21/2 3 1.610 1.900 0.145 40 x 65 80 40.9 48.3 37 1315030 2015030 3-4 3 1.610 1.900 0.145 80-100 80 40.9 48.3 3.7 1315050 2015050 5-8 3 1.610 1.900 0.145 125-200 .80 40.9 48.3 3.7 1320020 2020020 2 3 2.067 2.375 0.154 50 80 52.5 60.3 3.9 1320025 2020025 21/2 3 2.067 2.375 0.154 65 80 52.5 60.3 3.9 1320030 2020030 3 3 2.067 2.375 0.154 80 80 52.5 60.3 3.9 1320035 2020035 2 x 4 3 2.067 2.375 0.154 50 x 100 80 52.5 60.3 3.9 1320050 2020050 5 3 2.067 2.375 0.154 125 80 52.5 60.3 3.9 1320060 2020060 6 3 2.067 2.375 0.154 150 80 52.5 60.3 3 9 1320080 2020080 8 3 2.067 2.375 0.154 200 80 52.5 60.3 3.9 Note:Tee-Lets are manufactured to fit size-on-size,that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting,a slight gap of approximately 1/22"will appear along the longitudinal centerline of the header. For example,a 1"C 2 -21/2" is a 1'outlet fitting manufactured to fit perfectly on the 2°header size listed,while leaving a 1222'gap along the longitudinal centerline of the 21/2"size. If a perfect fit is required for a 21h"header pipe,then a 1'x 21/2-3'Tee-Let would be ordered.Size consolidations are employed to reduce inventory and provide for greater flexibility. /IN V- Star- -5- Fire P,och I,-:L Division MERIT Weld-MiserTM Tee-Let® Type B Type Type C/R Male Thre•d Cut Gr.•ve Roll Groove Welding Outlet Fittings Standard We'• t Standard -ight Schedule 10 E A I E I _ A lam- E -'I-- --- A ICII } i .. F I IL F 1-*--- D-4-I......= B I..., D-1'I B IUD B WELD-MISERTM TEE-LET' - DIMENSIONS (NOMINAL SIZES 21/z''THRU 8') Cut Nominal Nominal Outlet Inside Diameter - 0 Outside Wall Thickness - F Male Thread Roll Groove g Standard Schedule Standard Schedule Groove Std. Outlet Header Length Diameter Std.Wt. Wt Sch.10 A B C Weight 10 E Weight 10 NPT(080-7-1) NPT(IS0-7-1) NPT(ISO-7-1) ln.(mrn) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) In.(mm) 1325025 2025025 2225025 214 3 2.469 2.635 2.875 0.203 0.120 2125025 65 80 62.7 67.0 76.2 5.0 3.0 1325030 2025030 2225030 3 3 2.469 2.635 2.875 0.203 0.120 2125030 80 80 62.7 67.0 75.2 5.0 3.0 1325035 2025035 2225035 4 3 2.469 2.635 2.875 0.203 0.120 2125035 214 x 100 80 62.7 67.0 76.2 5.0 3.0 1325050 2025050 2225050 55 r 5 3 2.469 2.635 2.875 0.203 0.120 2125050 125 80 62.7 67.0 76.2 5.0 3.0 1325060 2025060 2225060 6 3 2.469 2.635 2.875 0.203 0.120 2125060 175 80 62.7 67.0 76.2 5.0 3.0 1325080 2025080 2225080 8 3 2.469 2.635 2.875 0.203 0.120 2125080 200 80 62.7 67.0 76.2 5.0 3.0 1330030 2030030 2230030 3 3 3.068 3.260 3.500 0.216 0.120 80 83 78.0 83.0 88.0 5.0 3.0 1330035 2030035 2230035 31 3 3.068 3.260 3.500 0.216 0.120 85 80 78.0 83 0 88.0 5.0 3.0 1330040 2030040 2230040 4 3 3.068 3.260 3.500 0.216 0.120 3 x 100 80 78.0 83.0 88.0 5.0 3.0 1330050 2030050 2230050 5 3 3.068 3.260 3.500 0.216 0.120 125 80 78.0 83.0 88.0 5.0 3.0 1330060 2030060 2230060 6 3 3.068 3.260 3.500 0.216 0.120 150 80 78.0 83.0 88.0 5.0 3.0 1330080 2030080 2230080 8 3 3.068 3.260 3.500 0.216 0.120 200 80 78.0 83.0 88.0 5.0 3.0 1340040 2040040 2240040 4 4 4.026 4.260 4.500 0.237 0.120 100 100 102.0 108.0 114.0 6.0 3.0 1340050 2040050 2240050 5 4 4.026 4.260 4.500 0.237 0.120 4 x 125 100 102.0 108.0 114.0 6.0 3.0 1340060 2040060 2240060 10O' 6 4 4.026 4.260 4.500 0.237 0.120 150 100 102 0 108.0 114.0 6.0 3.0 1340080 2040080 2240080 8 4 4.026 4.260 4.500 0.237 0.120 200 100 102.0 108.0 114.0 6.0 30 - 2060060 2260060 6 4 6.065 6.357 6.625 0.280 0.134 6 x 150 100 155.0 161.5 168.3 7 1 3.0 - 2060080 2260080 150x 8 4 6.065 6.357 6.625 0.280 0.134 200 100 155.0 181.5 168.3 7.1 3.0 - 2080080 - 8 x 8 4 7.981 8.329 8.625 0.322 0.148 200 x 200 100 203.0 212.0 213.0 8.0 3.0 Note:Tee-Lets are manufactured to fit size-on-size,that is the contoured shape on a given Tee-Let is made to fit perfectly on the first listed header size. If installed on the second header size marked on the fitting,a slight gap of approximately 142"will appear along the longitudinal centerline of the header. For example,a 1"x 2 -21/2'Tee-Let,Is a 1"outlet fitting manufactured to fit perfectly on the 2"header size listed,while leaving a 142"gap along the longitudinal centerline of the 2W size. If a perfect fit is required for a 214"header pipe,then a 1'x 214-3'Tee-Let would be ordered.Size consolidations are employed to reduce inventory and provide for greater flexibility. AnivAtStar- Fire Products Division Afrovo,1441,4* ,L MERIT Threading Practice Weld-MiserTM Tee-Let° Elw i„,ea° Elleaki•Th,ead °.r V %„ Installation W+It irLt i9�, lkuh Form.-. TO' ttt°'M in Male Ppe Welding Outlet Fittings PllC ILe )I1i1�IIIii ph' I m Ni 1' /,N,wwa:menr rmr IIIIIIIIVIhI l.,4e My.t:r:ee -- Art mthread &mama*den lea.+Iatit lanai aRS.m,-e r�m,oe la},aia MERIT NPT THREAD FORM STANDARD NPT THREAD FORM NPT TAPERED PIPE THREADS Tee-Let' thread form is consistent with Aeronautical National Form (ANPT)AS71051.The thread is fully formed over both the L-1 hand Drop Nipple Total L2 or 7ee•Lel LT L3 L1- L3 Effective tight and L-3 wrench tight threads. NPT tapered threads are typically Outlet Size Hand Tight Wrench Tight Length Threads gauged only over the L-1 threads.This makes Tee-Lets more forgiv- In.(nrm) ln.(mm) Threads Minn) Threads In.(mmi Threads In.(mm) Threads ing of field cut threaded pipe that may only marginally conform to the 1h' 0.320 4 48 0.214 3.00 0.534 748 0.534 747 specification.Fewer leaks translate into lower costs. 15 8.i 5.4 13.6 13.6 3/4' 0.339 4.75 0.214 3.00 0.553 7.75 0.546 7.64 20 8.6 5.4 14.0 13.9 1' 0.400 4.60 0.261 3.00 0.661 7.60 0.683 7.85 25 10.2 6.5 16.8 173 Ease of Installation 1W 0.420 0.261 0.681 0.707 ' 4E3 3.00 7.83 8.13 i 32 10,7 6.6 17.3 18.0 140 0.420 0.261 0.697 0.724 111.1 hi 4.83 3.00 7.83 8.32 40 .43 0261 177 18.4 2" 0.436 0.261 0.706 0.757 IJIPP--.1111 5.01 3.00 8.01 8.70 !am 50 11.1 6.6 179 19.2 ► Sd 21, ' 0.682 0.250 0.932 1.138 65 173 5.46 6.4 2.00 23.7 7.46 2E9 9.10 3 01966 0.250 1.016 1.200 80 .76 6.13 6 4 2.00 25.8 8.13 30.5 9.60 ..__) 4 0.844 6.75 0.250 2.00 1.094 8.75 1.300 10.40 100 21.4 6.4 27.8 33.0 Merit Manufacturing Tee-Lets are designed to sit higher on the pipe, Domestic Manufacture thereby requiring less weld and eliminating burn through. Tee-Lets Increasingly,federal,state,municipal,and quasi municipal authorities sit higher on the header or branch line pipe than competitive fittings. require domestic content for fire sprinkler systems.Merite Tee-Lets® This allows the welding torch to remain in an optimum position for meet these requirements.The need to maintain dual inventories;one welding. In addition,11/2"and larger Type A female threaded and Type domestic;one import is eliminated. C grooved Tee-Lets require the same hole size for installation.This re- sults in fewer change overs when installed using automatic welders. Welding Practice When measured with respect to linear inches of weld required for 1--2.65o'- I-- 2.820'- installation,Tee-Lets require up to 15% less weld than competitive fittings.This reduces time and savings over time are substantial. Therr. diameter of the contoured end of Type A Tee-Lets has been reduced so ,, ,s, that the wall thickness more nearly matches the header or branch line ,065-;7` 44'.' , pipe wall thickness.Therefore,current and voltage settings required - .'r, for welding are set to provide for adequate penetration without burn --' 205"- .325"-I - through and cold shutting.Also,weld volume required for installation 2"Merit Weld-Miser 2"Competitive 8 is lower for Tee-Lets than most other fittings.Typically,Tee-Lets re- Tee-Let Fitting quire one-weld pass for attachment. WELDING PRACTICE Outlet MERIT WELD-MISER TEE-LET COMPETITIVE FITTING Size WELD VOLUME' LINEAR WELDING WELD VOLUME* LINEAR WELDING In.(rem) CrnSS Sec.Area %less In.(mm) %less Cross Sec.Area %mare In.(mm) %less 1" 0.051 sq.in. 12% 2.48 ° 12 iO 0.058 sq.in. 2.48 0% 0% 25 32.9 sq mm 62.9 37.4 sq mm 62.9 1W 0.037' 48% 2.88 4°/ 0.063 48% 3.01 4% 32 20.6 73.1 40.6 76.4 1W 0.036' 40% 3.12 10% 0.060 4U°/ 3.46 10% 40 23.2 79.2 38.7 87.8 2" 0.040" 62% 3.77 15% 0.106 62% 4.41 15% ,.50 25.8 95.7 68.3 112.0 AN Star- -'- Fire Products Division MERIT Weld-MiserTM Tee-Let® Installation (cont.) _ Welding Outlet Fittings I (RECOMIENDED AMOUNT OF WELD A \/ [C Outlet A B Size Recommended Installation Procedures IL_� /nimm In/mm fnfrnm 3/16 Merit Weld-Miser Tee-Let Welding Outlet Fittings are B 13 7 5 designed and manufactured to reduce the cost of installa- y %, 3/6 tion from both the standpoint of labor required and energy 19 7 5 consumed. In addition,by following the recommended in- 1 % 'A6 stallalion procedures,many of the problems associated with '/2,%& 1 Outlet 25 7 5 %installing welding outlet fittings on standard weight or light ii, �A' weight pipe are eliminated,including burn through and excessive I 31 'A 5 shrinkage resulting in pipe distortion. I 38 8 76 Recommended Hole Sizes 1..... 2 A6 1 50 8 7 The hole cut in the branch or header pipe can be cut prior or sub- j p+,� 'A6 y, sequent to attachment of the Tee-Let.One advantage of cutting the - ---1----- -- 63 8 7 hole after welding is that the pipe is lett intact during welding thereby 1 3 % 'A6 reducing shrinkage and possible distortion,If holes are cut prior to I 75 10 5 welding,as some codes require,then the following hole sizes are 4 % '46 recommended.Note that the same hole diameter for a given outlet 11/2-21/2 Outlet 100 10 5 size is required for both Type A and Type C Tee-Lets 1-1'/2°larger. Recommended Welding Procedures Merit Weld-Wiser Tee-Lets are designed to be installed on standard weight or light weight pipe with one weld pass on Type A outlet sizes from 1h"through 2'/2"inclu- sive,and on Type C outlet sizes through 4".Moreover,the wall thickness at the weld end of the fitting approximately matches standard weight pipe.Accordingly, RECOMMENDED TEE-LET heat setting can be made to optimize penetration on both the fitting and the pipe HOLE SIZES which It is being welded.Aside from reducing the likelihood of burn through and Tee Let Size Type Recommended 9 9 u9 Hole Size distortion resulting from excessive heat,the amount of weld required for adequate In inn fn./mm penetration is significantly reduced. A Type A ii Merit Tee-Lets are manufactured from continuous cast aluminum killed steel with a 13 16 carbon range of from 0.05 to 0.25.Merit specifies that residuals,such as chrome, 'A Type A g nickel and other metals resident in the scrap used for production of the steel be i9 22 1 Type A 1% reported and kept to a minimum.On the other hand,certain grades of carbon 25 28 steel pipe are manufactured from skelp whose chemical composition is not sped- 1% Type A 1' fied.When the metal inert gas shield(MIG)welding process is employed,certain 31 38 residuals may cause excessive porosity,spatter or lack of penetration.Specifically, 1'h Type C 1% gases released during the welding process do not escape before the molten puddle 31 35 sets up.When porosity or lack of penetration occurs,one approach is to slightly 1'% TypeAorC 1'%e increase the heat in order to give the gases time to escape from the puddle.A flux as 41 cored wire can also be used.This wire contains scavengers which allow gases in 2 TypeAorC 2 the molten weld puddle to escape before the weld solidifies.The following recom- 50 50 mended settings for welding therefore may need to be adjusted slightly higher if any 2h 7ypeAorC 2 63 61 of the above mentioned adverse conditions exist. 3 TypeAorC 3 As a general rule,the weld should be only as hot as required to allow the weld to 75 75 penetrate the materials being welded while concomitantly allowing gases developed 4 TypeAorC 4 in the welding process to escape.Every effort must be made to avoid welding too 100 100 hot or overheating both the pipe and the Tee-Let.Excessive heat may cause the Holes may be cut employing mechanical means-including hole sawing, wrench tight threads(those in the bottom of the Tee-Let near the weld zone)to mechanical flame cutting(oxy-acetylene or propane),and air plasma cutting distort while also causing the branch pipe to bend.It should be noted that Merit (constricted tungsten arc)machines Merit otters a simple approach to cut Tee-Lets have been subjected to exhaustive testing and evaluation,and only negli- ring the hole. Hand-held templates are sized to match your plasma cutter. gibly distort when subjected to excessive heat.The threads,on the other hand,may not return to their gauged form after cooling if excessive heat causes them to expand. The following is intended only as a guide,and assumes that the welding equipment is properly calibrated and functioning normally and the operator is qualified. -8- AStar- Fire Protlucts IDosion = , 4 MERIT, Weld-Miser TM Tee-Let® Installation (cont.) Welding Outlet Fittings RECOMMENDED SETTINGS FOR MICROWIRE WELDING PROCESS CONTINUED ON NEAT PAGE Header Size Pipe Wall Thickness Tee-Lot Types A,B,C Electrode Welding Arc.Volts Wire Feed Travel Speed Site Current la./mm 1n./mm In./mm AMPS-DC POS. /PM IPM Iz-2 0.035 100 130 16-20 2'0 2530 0.065 13-50 2 2'k-4 0.035 115-150 17-21 270 20-25 VA-2 63-100 31-50 %-2 0.035 110-140 18-22 220 25-30 0.108 13-50 214-4 0.035 120-160 19-22 290 20-25 63-100 %-2 0.035 110-140 17-20 210 20-25 0.085 13-50 5 21,4-4 0,035 120-150 17-20 270 20-25 2+'h-4 63-100 63-100 '/s-2 0.035 120-160 19-22 29(1 20-25 0.120 13-50 3 2%-4 0.035 130-160 19-22 240 20-25 63-100 %-2 0.035 120-150 17-20 210 20-25 0109 13-50 3 2°, -4 0.035 130-150 18-20 270 15-20 63-100 5-6 'A-2 0.035 130-160 19-22 290 20-25 13-50 0.134 2'%-4 0.035 140.160 20-22 270 15-20 3.5 63-100 2'%-4 0.045 180-205 20-24 245 27-32 63-100 %-2 0.035 120-150 17-20 240 20.25 13-50 0.109 2'4-4 0.035 130-150 18-20 260 15-20 3 63-100 2'%-4 0.045 170-220 18-22 290 12-18 8 63-100 200 %-2 0.035 130-160 19-22 240 20-25 13-50 0.148 2'%-4 0.035 140-160 20-22 260 15-20 3.5 63-100 2'h-4 0.045 180-225 20-24 290 12-18 63-100 Shielding Gas Flow(FOR au SIZES)20-25 CFH Merit assumes no liability for any consequential damages resulting 1.)Co,-Deeper penetration,faster welding,low cost. from the improper use of its Tee-Let Welding Outlet Fittings,nor for 2.)25%-Argon,75%-Co,,Recommended for.134 wall and lighter,high welding speeds any recommendations made with respect to installation procedures. without me6 through,minimum distortion and spatter,good penetration. AM/ LStar -D Fire Products Division AF �� MERIT. Eliminator Adjustable Drop Nipples V AI APPROVED 5' "ze' EMI► lha Poriistine�appoval details canted ruur AnviSiar'Fepet aantati.t y . PRODUCT APPROVALS Eliminator Adjustable Drop Nipple: Merit Eliminator Adjustable Drop Nipples provide the user with the (UL VGSO-EX6033,FM Approval Guide Chapter 1-Adjustable Sprinkler ability to adjust fire sprinkler assemblies(concealed,recessed, or Fittings VdS Certificate#64930033 BSA:886.86-SA) pendent)to fit flush to the finished ceiling without having to cut a drop Adjustable Inlet x Outlet Equivalent Rated Max.Ceiling nipple or drain the system. Drop Modal Size Adjustment Length Pressure Amer •Available in two models,female or male thread inlet,with three Temperature re NPT In.(mm) In.(mnr) Ft.(M) psig F(0) standard lengths with adjustment up to 3'(7.62 cm) MR1.150 1 x Va 1 1 •UL Listed,FM Approved,and BSA-NYC Approved for installation or 25>r 25.4 o.3 to NFPA Bulletin 13 requirements.VdS Approved for the European M1.150 market. M3.150 1 x% 3 1 25x 13 76.2 0.3 •Cold formed from steel conforming to ASTM Grade. M3.175 1 x% 3 2.6 •Inner nipples employ two(2)"0-Rings"to provide added assurance 25x 19 76.2 0.8 of sealing. The"F"Model is designed to keep"0-Rings"from Im- ME3.150 1x'4 3 1 pinging upon the one inch (1')inlet threads when fully retracted. 25x 13 7&2 0.3 300 300° •The bore of the outer nipple Is precision formed to a close tolerance 11.150 1 x'/1 1 4.2 148° while held to a microfinish of 50 to provide for positive sealing of 25x13 25.4 1.3 the"0-Rings". F2.150 1 x'A 2 1.3 •Each unit is hydrostatically tested to insure"0-Ring"integrity prior 25x13 50.8 0.4 to shipment. F3.150 1 x 1A 3 1.5 •Each unit is marked with a lot number to insure full traceability. 25x 13 76,2 0.5 •Qualifying tests on all models are performed at 1500 PSI,while the F3.175 1 x' 3 2.9 various models are rated for 300 PSI operation. 25x 19 76.2 o..9 •Threads are cut to be better than or equal to the requirements of ANSI B1.20.1,NPT or ISO-7-1 threads. Martel Minimum Maximum Maximum Maximum Number Part# Inlet Outlet Length Length Adjustment Sprinkler Weight Orifice NPTASO NPTASO NPTASO In.(mm) In.(nun) In.(mm) In.(mm) Lbs.(kg) M1.150' 531150 1"Male 1h'Female 4.125 5.125 1.00 0.531 1.00 551150 25mm We 13m,n Female 104.8 1302 254 13.5 0.45 M3.150 533150 1'Male 1//2'Female 6.125 9.125 3.00 0.531 1.25 553150 25mm Male 13mm Female 155.6 231.8 76.2 13.5 0.57 ME3.150' 543150 1"Male 1/2"Female 7.875 10.875 3.00 0.531 1.50 563150 25mm Male 13mm Female 200.0 276.2 762 13.5 0.68 F1.150 501150 1'Female 1/2'Female 3.500 4-500 1.00 0.625 0.80 511150 25mm Female 13mm Female 88.9 114.3 25.4 159 036 12.150° 502150 1"Female 1/2"Female 4.500 6.500 2.00 0.625 1.00 512150 25mm Female Lamm Female 1143 16.5/ 508 159 04,5 F3.150 503150 1"Female 1/2'Female 5.500 8.500 3.00 0.531 1.25 513150 25mm Female 13mm Female 1397 215.9 76.2 13.5 0.57 F3.175 503175 1"Female 3/4'Female 7.350 10.350 3.00 0.625 1.40 513175 25mm Female 19mm Female 1857 262.9 76.2 15.9 084 *Special Order Length Tolerance s'/a -10- AStarm Fire Products Division l}' I$"' MERIT, Installation Eliminator A)For use in wet and dry pipe automatic sprinkler systems Installed in accordance with all appli- cable Adjustable D r0 Nipples standards or codes.(See item 4) p B)Before starling the job of making sprinklers into steel threads of the above fittings,count the number of fully developed male threads on the brand of sprinkler to be installed into the fittings. If seven(7)perfect threads are counted,the sprinkler should thread into the W or'/i'thread • MODEL 'F' INSTALLATION from three(3)to four(4)threads hand tight If live(5)to six(6)threads are counted,the sprinkler I should thread into the'h"or 4'thread from two(2)to three(3)threads hard light. • C)Use an anaerobic pipe thread sealant for thread make-up.Apply pipe thread sealant only to male ____-___ threads on the nipple and sprinkler only. T 1111-11 D)If either of the above fails to allow the sprinkler to make-up to a minimum of from five(5)to six(6)full threads,do not ovedighten the sprinkler.Instead back the sprinkler out of the fitting. MIN. elm Clean any debris and/or pipe sealant from both the male and female threads.Gauge both the MAX. MODEL'F' male threads of the sprinkler and the female threads of the Adjustable Drop Nipple for caliph- LENGTH ance with ANSI 812.1.Specification for Tapered Pipe Threads.The same procedure would apply If a leak has been detected. If within tolerance,reapply the anaerobic pipe sealant and make-on to the required length. y If, 7_It Allow twenty-four hours for setting. ,A E)Connect the Adjustable Drop Nipple assembly to the sprinkler system by wrenching on the CEILING TILE � make-up area on the Drop Nipple.DO NOT WRENCH ON THE BARREL PORTION OF THE SPRINKLER HEAD ,-7 I UNIT OR SPRINKLER.Damage to the Adjustable Drop Nipple or Sprinkler may result. F)After the ceiling has been installed adjust the sprinkler to its final position by using the sprin- kler wrench and assemble the escutcheon plate to the inner support ring.It Is recommended that the system pressure be relieved when adjusting,however it is not necessary to drain the • MODEL 'M' INSTALLATION system. , 1)GENERAL DESCRIPTION BRANCH PIPE y. Merit Eliminator Adjustable Drop Nipples Models"M"and"F"are the screw type consisting of an outer case which has one(1)Inch N.P.T.or ISO-7 male or female thread on the inlet,and an Inner T fel case which has either a one-half inch('k')or a three-quarter Inch('A")N.P.T.sprinkler connection. The inner case employs 0-Ring Seals and adjusts either in or out over the range of the adjustment. MIN. MODEL'M' Merit Eliminator Adjustable Drop Nipples are designed for use in automatic fire sprinkler systems MAX. installed in accordance with all applicable standards or codes.(See item 4). LENGTH N The purpose of these fittings is to allow for the final adjustment of the drop nipple between a p branch line and a pendant sprinkler by eliminating the need to re-cut the existing drop nipple in III order to fit-up flush to the ceiling.Merit Eliminator Adjustable Drop Nipples do not require any MIMI=F7.a secondary locking following final adjustment and they will not extend as a result of vibrations or pressure surges in the system. CEILING TILE 2)APPROVALS AND STANDARDS SPRINKLER HEAD Merit Eliminator Adjustable Drop Nipples are listed by the Underwriters Laboratories,Inc.(UL Listing Number 5750)and approved by the Factory Mutual Research Corporation(FM).In addi- tion,Model"M"and"F'Adjustable Drop Nipples are approved by the New York Board of Materials • DRAWING OF MODEL 'M' & 'F' and Equipment Standard(BSA-886-86-5A)and verband der Schadenversicherer e.V.,(Vds). 1"NPT OR ISO 1'NPT OR ISO 3)TECHNICAL DATA MALE THRD FEMALE THRD Merit Adjustable Drop Nipples are rated for use at a maximum temperature of 300°F,and a maxi- INLET INLET mum service pressure ol 300 psi. The approximate friction loss based on the Hazen and Williams Formula expressed in equivalent A length of one(1)inch,schedule 40 pipe(where Cr 120)is 1'for''h'outlet Model"M",2.6'for'/:' . outlet Model'M",4.2'for Fl,1.3'for F2,1.5'for F3.150,and 2.9'for F3.175. Merit Eliminator Drop nipples maximum sprinkler orifice size for Models M3.150,ME3.150, '� M1.150,and F3.150 is°/ss°and Models F1.150,F2.150,F3.175 and M3.175 is sli". The inlet and outlet threads conform to ANSI B1.20.1 1 ISO-7R/AC. The 0-Ring seals used in the manufacture are an ethylene propylene elastomer(EPDM).The MIN., II MIN., outer and inner casings are manufactured from high strength carbon Steel. LENGTH 5 I LENGTH All Model"M"and"F"Adjustable Drop Nipples are hydrostatically tested for 0-ring integrity prior to shipment. 'l 4)WARNING 1 Adjustable Drop Nipples described herein must be installed and maintained in compliance with t- I this document as well as the applicable standards of the National Fire Protection Association in addition to the standards for any other authorities having jurisdiction.DO NOT USE ANY M i r 0 PETR LEUM BASED LUBRICANTS ON THE 0-RING SEALS.Petroleum based lubricants are incompatible with EPDM and will impair serviceability of the unit. '4'NPT 4 ''/,"or%d'NPT FEFJALETHRO FEMALE THRD OUTLET OUTLET f Star'" —11 N [Ire Products Dwisicn Aklk MERIT - Flanges Steel Welding Flanges • Steel Welding Flanges are manufactured to comply with the American Water Works Association C207,Table 1,Class D specification for steel — plate flanges. In those sizes not covered by AWWA C207,design data was extracted from the specification and employed for sizes 3'and + smaller.All sizes manufactured are UL Listed and FM Approved for 175 psi at ambient temperature up to and including 12'sizes,while sizes g over 12"are rated for 150 psi at ambient temperature. National Steel ek P_ Plate Flanges have the same diameter and bolt hole drilling as class 125 cast iron flanges per ANSI, B16.1.For size 24"and smaller,Nation- al Steel Plate Flanges also match ANSI B16.5,150-pound class.Steel UL plate flanges,aside from lower initial cost,are generally considered to ® L be easier to install during make up and final Installation. APPROVED Available Slip-On,Reducing and Blind. Foe ihnng/approves deiei a co,/act yourA-MISbr'Represertati •Pressure rating at ambient temperature for sizes 2"-12'—175 psi. •Flanges have the same diameter and drilling as Class 125 cast-iron flanges (ANSI 16.1). •Priced significantly lower than forged steel welding flanges. •UL Listed and FM Approved. •Conform to AWWA C207 Class D. NATIONAL STEEL FLANGES (NATIONAL FITTINGS LISTINGS: UL HKOK-EX5222, FM APPROVAL GUIDE CHAPTER 1 - PIPE FITTINGS) Model Configuration Size(Inch) Raled Pressure(psig) PFB Blind Flange 2,2 1,3,4,5,6,8,10 812 175 PFS Slip-On Flange(Ring Type) 2,2 1,3,4,5,6,8,10 812 PFR Reducing Flange 4x2,4x21/2,4x3,6x3,6x4,8x4,8x6 A A-Star- -13 Fire Products Division AA:4N MERIT Flanges Steel Welding Flanges < IE A B '1 1 L` 1 A B ' 1 ' 1 A J 1 I i-I ! T _ _ T 111��1111 T i< C i < c ---->i # i n # Slip-On Reducing Blind Number Nominal Reducing Inside Diameter B Bolt Circle Thickness Bolt Hale Pan Number/Model Size Pipe Site O.D.A 111.01110 C T of Bolls Diameter Required Slip-On Blind Reducing In.(mm) In.(mm) In.(;;Im) Slip an Reducing In.(mm) In.(mm) In(um) In.(mm) 400200 410200 - 2* - 6 3 2 44 4.75 .5 4 .750 50 - 172.4 76.2 62.0 120.7 75.9 - 19 400250 410250 42025020 21 21/2 x 2 7 3 2.44 5.5 .5 4 .750 65 65x50 1778 76.2 62.0 1397 15.9 - 19 42030020 3* 3 x 2 8 3.6 2.44 6 .5 4 .750 400300 410300 80 80x50 790-5 914 62.0 152.4 15.9 - 19 42030025 3* 3 x 21 8 3.6 2.97 6 .5 4 .750 80 80 x 65 190.5 91.4 75.4 152.4 15.9 - 19 430400 410400 42040020 4 4 x 2 9 4.6 2.44 7.5 .625 8 .750 100 700 x 50 228.65 116.1 62.0 190.5 15.9 19 42040025 4 4 x 21 9 4.6 2.97 7.5 .625 8 .750 100 100 x 65 228.65 1161 75.4 190 5 15 9 - 10 - - 4 4 x 3 9 4.6 3.6 7.5 .625 8 .750 42040030 /00 100 x 80 228.65 116.1 91.4 190.5 15,9 - 19 5 - 10 5.7 - 8.5 .625 8 .875 125 - 254 143.8 215.9 15 9 - 22 5 - 10 5.7 - 8.5 .625 8 .875 400500 410500 _ 125 254 143.8 - 215.9 15.9 - 22 5 - 10 5.7 - 8.5 .625 8 .875 125 - 254 143.8 - 215.9 15.9 - 22 5 - 10 5.7 - 8.5 .625 8 .875 125 - 254 143.8 - 215.9 15.9 - 22 42060020 6 6 x 2 11 6.7 2.44 9.5 .688 8 .875 150 150 x 50 279.4 170.7 52.0 241.3 17.5 - 22 42060025 6 6 x 21 11 6.7 2.97 9.5 .688 8 .875 400600 410600 150 1501(65 2794 179.7 75.4 241.3 17.5 - 22 42060030 6 6 x 3 11 6.7 3.60 9.5 .688 8 .875 150 150 x 80 279.4 170.7 91.4 241.3 17.5 - 22 42060040 6 6 x 4 11 6.7 4.57 9.5 .688 8 .875 150 150 x 100 279.4 170.7 116.1 241.3 175 - 22 42080030 8 8 x 3 14 8.7 2.97 11.75 .688 8 .875 200 200x 80 342.9 221.5 75.4 298.5 17.5 - 22 400800 410800 42080040 8 8 x 4 14 8.7 4.57 11.75 .688 8 .875 200 200 x 100 342.9 221.5 116.1 298.5 17.5 - 22 42080060 8 8 x 6 14 8.7 6.72 11.75 .688 8 .875 200 200 x 1.50 342.9 221.5 170.7 298.5 17.5 - 22 42100060 10 10 x 6 16 11 6.72 14.25 .812 12 1 401000 411000 250 250x 150 406.4 276.4 170.7 362.0 20.6 - 25 42100080 10 10 x 8 16 11 8.70 14.25 .812 12 1 250 250 x 200 406 4 276.4 221.5 362.0 20.6 - 25 401200 411200 12 - 19 13 -- 17 .938 12 1 300 - 482.6 327.2 431.8 23.8 - 25 -14- A Star°' Fire Products Division QUICK RESPONSE GL .49 BE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT• PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL CONVENTIONAL (OLD STYLE) DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinklers are a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. e jeak. r While the Quick Response Sprinkler provides an aesthetically pleasing appearance, it can be installed wherever standard spray III III sprinklers are specified when allowed by the applicable standards. It offers the additional feature of greatly increased safety to life and is available in various styles, orifices, temperature ratings and finishes to meet many varying design requirements. Quick QUICK RESPONSE Response Sprinklers should be used advisedly and under the UPRIGHT CONVENTIONAL direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed m ° in an approved pattern depending upon the deflector style used. QUICK RESPONSE TECHNICAL DATA PENDENT VERTICAL •See reverse side for Approvals and Specifications. SIDEWALL •Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) OA' •Water Working Pressure Rating - 175 psi (12 Bars) •Factory tested hydrostatically to 500 psi (34 Bars) •Maximum low temperature glass bulb rating is -67°F (-55°C) QUICK RESPONSE •Frame - bronze • Deflector- brass • Screw- brass HORIZONTAL LPClCE •Lodgement Wire - stainless steel • SIDEWALL HORIZONTAL •Bulb seat - copper • Spring - nickel alloy • Seal - teflon SIDEWALL •Bulb - glass with alcohol based solution, 3mm size •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 4ii„ a #' INTERMEDIATE 175°F1200°F 79°C/93°C YELLOW/GREEN a °. c3 HIGH 286°F 141°C ,, BLUE w„ . P ,, ,t 4077AI RPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2012 A-20 BULLETIN GL5615, REV. #9 • QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT, PENDENT S VERTICAL SIDEWALL HORIZONTAL SIDEWALL a CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7cm) 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7cm) Factory Bronze Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7cm) 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7cm) White Polyester 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2cm) Black Polyester 2'3 METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". 'FINISHES AVAILABLE ON SPECIAL ORDER. / 'AVAILABLE AS cULus LISTED CORROSION RRO VAL IFI�+ ED ON ORDER. STYLE SIN K H�4ZARD� 135°F 155°F 11775°F 200°F 286°F cULus FM LPC CE NYC-DOB MODEL FACTOR 57°C 68°C 79°C 93°C 141°C MEA 101-92-E GL2815 2.8 LH X X X X X X — — — X GL4215 4.2 LH X X X X X X — — — X UPRIGHT G15615 5.6 LH/OH X X - X X X X X X X X GL8115 7.8° LH/OH X X X X X X — — — X GL8118 8.1 LH/OH X X X X X X X X X X GL2801 2.8 LH X X X X X X — — — X GL4201 4.2 LH X X X X X X — — — X PENDENT GL5601 5.6 LH/OH X X X X X X X X X X GL8101 7.8° LH/OH X X X X X X X — — X GL8106 8.1 LH/OH X X X X X X X X X X VER11CAL GL5632 5.6 LH X X X X X X X — — — SIDEWALLt GL8133 8.1 LH X X X X X X — — — — GL2826§ 2.8 LH X X X X X X — — — X HORIZONTAL GL4226§ 4.2 LH X X X X X X — — — X SIDEWALL GL5626§ 5.6 LH/OH X X X X X X X — — X GL5627o 5.6 LH/OH X X X X X — — X X — GL8127§ 8.1 LH/OH X X X X X X — — — — CONVENTIONAL GL5624 5.6 LH/OH X X X X X — — X X — (OLD STYLE) GL8125 8.1 LH/OH X X X X X — — X X — 1SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING,FM APPROVED 4"TO 6"BELOW THE CEILING. INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. 'PENDENT VERTICAL SIDEWALL cULus LISTED FOR 6'MIN.SPACING. tUPRIGHT VERTICAL SIDEWALL cULus LISTED FOR 9'MIN.SPACING. OH; ORDINARY HAZARD LH: LIGHT HAZARD "1/2"NPT ORDERING INFORMATION GLOBE®PRODUCT WARRANTY SPECIFY •Quantity • Model Number • Style Globe agrees to repair or replace any of its own manufactured •Orifice • Thread Sizes • Temperature products found to be defective in material or workmanship for a •Finishes desired period of one year from date of shipment. •Quantity-Wrenches-PIN 325390 (1/2"); For specific details of our warranty please refer to Price List P/N 312366 (L.O.) Terms and Conditions of Sale (Our Price List). CL f,- Ex 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com JUNE2012 PRINTED U.S.A. BULLETIN GL5615,REV.#9 • QUICK RESPONSE C ® AUTOMATIC SPRINKLERS L ® S GL SERIES FIRE SPRINKLER CORPORATION RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL DESCRIPTION AND OPERATION The Globe Quick Response GL Series Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation approximately six times faster than ordinary sprinklers. While the r r Quick Response Sprinkler provides an aesthetically pleasing ap- pearance, it can be installed wherever standard spray sprinklers are specified but offers the additional feature of greatly increased rir safety to life. Quick Response Sprinklers should be used advisedly and underthe direction of approving authorities having jurisdiction. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that QUICK RESPONSE contains a precisely measured amount of fluid. When heat is RECESSED PENDENT absorbed,the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used The sprinkler and escutcheon are not factory assembled Assembly is done in the field. ' 2d I' h TECHNICAL DATA 0 j y. •See reverse side for Approvals and Specifications. , •Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) •Water Working Pressure Rating - 175 psi (12 Bars) QUICK RESPONSE RECESSED •Factory tested hydrostatically to 500 psi (34 Bars) HORIZONTAL SIDEWALL •Maximum low temperature glass bulb rating is -67°F (-55°C) •Frame - bronze • Deflector - brass • Screw - brass •Bulb seat- copper • Spring - nickel alloy • Seal - teflon •Bulb - glass with alcohol based solution, 3mm size •Escutcheon Assembly - steel •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM TEMPERATURES CEILING TEMPERATURE ORDINARY 135°F/155°F 57°C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150`F 66°C HIGH 286°F 141°C BLUE 225°F 107°C 4077AIRPARK DRIVE,STANDISH,MICHIGAN 48658 989-846-4583 • FAX989-846-9231 JULY 2009 A-24 BULLETIN GL2801, REV. #8 QUICK RESPONSE AUTOMATIC SPRINKLERS GL SERIES RECESSED PENDENT RECESSED HORIZONTAL SIDEWALL SPECIFICATIONS NOMINAL "K" FACTOR THREAD SIZE LENGTH ' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Satin Chrome 2 Bright Chrome 5.6 (80 metric) 1/2" NPT 2 1/4" (5.7 cm) White Polyester3 7.8 (111 metric) 1/2" NPT 2 1/4" (5.7 cm) Black Polyester3 8.1 (116 metric) 3/4" NPT 2 7/16" (6.2 cm) Lead Coated 2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'HORIZONTAL SIDEWALL IS 2 9/16". °FINISHES AVAILABLE ON SPECIAL ORDER. 'cULus LISTED CORROSION RESISTANT- POLYESTER MUST BE SPECIFIED ON ORDER. APPROVALS STYLE K 135°F 155°F 175°F 200°F "286°F cULus ttFM LPC CE NYC-DOB MODEL FACTOR 67°C 68°C 79°C 93 C 141°C MEA101-92-E GL2801 2.8 X X X X X X — -- — X GL4201 4.2 X X X X X X — X PENDENT GL5601 5.6 X X X X X X X X X X RECESSED GL8101 7.8• X X X X X X X — — X GL8106 8.1 X X X X X X X a X X X GL2826 2.8 X X X X X X — — — X HORIZONTAL GL4226 4.2 X X X X X X — — — X SIDEWALL RECESSED§ GL5626 5.6 X X X X X X — — — X GL8127 8.1 X X X X X X — — — — §HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING. t5.6K ORIFICE,7.8K ORIFICE AND 8.1K ORIFICE LISTED FOR ALL HAZARDS. •CROSS SECTIONS 7.8K T "NPT. "286°F cULus LISTED ONLY. tt 1/2"RECESSED ESCUTCHEONS ARE REQUIRED FOR FM APPROVED SPRINKLERS. $BRASS FINISH ONLY 2 15n6'D,—■ 122/32'CIA ORDERING INFORMATION RE'"E• 11 I' ::,c ,'" SPECIFY "" •Quantity • Model Number • Style )��.Tia •Orifice • Thread Sizes • Temperature � "' "" • Finishes desired It_ _° •Quantity- Recessed Wrenches-P/N 325391 (1/2"); u* „,;, P/N 325401, Rev. F(L.O.) 1 • Quantity-Protective Caps-P/N 327109-CAP PENDENT I (Friction Fit Recessed) rA=-.o:„m I o °=' ` p GLOBE® PRODUCT WARRANTY Globe agrees to repair or replace any of its own manufactured products found to be defective in material or workmanship for a period of one year from date of shipment. " °„,---Li_ For specific details of our warranty please refer to GL ® BE Price List Terms and Conditions of Sale(Our Price List). HORIZONTAL ® SIDEWALL 4077AIRPARKDRIVE,STANDISH,MICHIGAN 48658 FIRE SPRINKLER CORPORATION 989-846-4583 FAX 989-846-9231 1-800-248-0278 www.globesprinkler.com JULY 2009 PRINTEDU.S.A. BULLETIN GL2801, REV. #8 STANDARD RESPONSE ,� AUTOMATIC SPRINKLERS ` GL SERIES UPRIGHT • PENDENT FIRE SPRINKLER CORPORATION VERTICAL SIDEWALL HORIZONTAL SIDEWALL ) DESCRIPTION AND OPERATION CONVENTIONAL (OLD STYLE The Globe GL Series Sprinkler is a low profile yet durable design which utilizes a frangible glass ampule r i intas the thermosensitive element. While the sprinkler ` ; provides an aesthetically pleasing appearance, it can be installed wherever standard spray sprinklers are ' . specified. This sprinkler series is available in various ' styles, orifices, temperature ratings and finishes to UPRIGHT CONVENTIONAL meet varying design requirements. The heart of Globe's GL Series sprinkler proven actuating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured s amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water " " discharge which is distributed in an approved pattern ` depending upon the deflector style used. PENDENT VERTICAL TECHNICAL DATA SIDEWALL •See reverse side for Approvals and Specifications. •Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F (79°C), 200°F (93°C) 286°F (141°C), 360°F (182°C) 1 ,, j t •500°F (260°C) Available Upon Request Without Approvals "'; r "II`` :I I'"4 •Water Working Pressure Rating - 175 psi (12 Bars) -�. • Factory tested hydrostatically to 500 psi (34 Bars) HORIZONTAL LPC/CE •Maximum low temperature glass bulb rating is -67°F (-55°C) SIDEWALL HORIZONTAL SIDEWALL •Frame - bronze • Deflector- brass • Screw- brass • Lodgement Spring - stainless steel •Bulb seat - copper•Spring - nickel alloy • Seal - teflon •Bulb - glass with glycerin solution, 5mm size • SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE BULB COLOR N.F.P.A. MAXIMUM SPRINKLER TEMPERATURES CEILING TEMPERATURE ORDINARY V14341::1;:frApiTRA ORANGE/RED a °' '°"°"4 INTERMEDIATE 6 QilnfaiTti2Phf#A41 YELLOW/GREEN refOige.µ HIGH BLUE < EXTRA HIGH :m€ MAUVE a�' ULTRA HIGH °a`: a o' ,®' BLACK 3 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583•FAX 989-846-9231 JULY 2012 A-65 BULLETIN GL5661, REV. #6 STANDARD RESPRONSE AUTOMATIC SPRINKLERS GL SERIES UPRIGHT • PENDENT • VERTICAL SIDEWALL HORIZONTAL SIDEWALL • CONVENTIONAL (OLD STYLE) SPECIFICATIONS NOMINAL"K"FACTOR THREAD SIZE LENGTH' FINISHES 2.8 (39 metric) 1/2" NPT 2 1/4" (5.7 cm) 4.2 (59 metric) 1/2" NPT 2 1/4" (5.7 cm) Factory Bronze Chrome 5.6 (80 metric) 1/2" NPT 2 1/4"(5.7 cm) White Polyester 3 7.8 (111 metric) 1/2" NPT 2 1/4"(5.7 cm) Black Polyester 23 Wax Coated 2.3d 8.1 (116 metric) 3/4" NPT 2 7/16"(6.2 cm) METRIC CONVERSIONS ARE APPROXIMATE 1 HORIZONTAL SIDEWALL IS 2 9/16'. 2 FINISHES AVAILABLE ON SPECIAL ORDER. 3 AVAILABLE AS cULus LISTED CO °SION RESISTANT WHEN SPECIFIED ON ORDER. WAX COATING cULus LISTED O 200°F ONLY. APPROVALS STYLE HAZARD'K HAZARD' 135°F 155°F 175°F 200°F 2136°F NYC-DOB 6°F ""360°F "500°F cULus FM LPC CE MODEL FACTOR 57°C 68°C 79°C 93°C 141°C 182°C 260°C MEA 101!92-E GL2861 2.8 LH X X X X X X X X — X GL4261 4.2 LH X X X X X X X X — — — X UPRIGHT GL5661 5.6 ALL X X X X X X X X X X X X GL8161 7.8° ALL X X X X X X X X — X GL8164 8.1 ALL X X X X X X X X X X X X GL2851 2.8 LH X X X X X X X X — — — X GL4251 4.2 LH X X X X X X X X — — — X PENDENT GL5651 5.6 ALL X X X X X X X X X X X X GL8151 7.8* ALL X X X X X X X X X — — X GL8156 8.1 ALL X X X X X X X X X X X X VERTICAL GL5675 5.6 LH X X X X X X X X X — -- X SIDEWALL$ GL8176 9.1 LH X X X X X X X X X GL2870§ 2.8 LH X X X X X X X X — — — X GL4270§ 4.2 LH X X X X X X X X — — — X HORIZONTAL GL5670§ 5.6 LWOH X X X X X X X X X -- — X SIDEWALL GL567113 5.6 LWOH X X X X X X X — — X X — GL8171§ 8.1 LH/OH X X X X X X X X — — — — CONVENTIONAL GL5668 5.6 LH/OH X X X X X X X — — X X — (OLD STYLE) GL8169 8.1 LH/OH X X X X X X X — — X X — 1 SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. `•360°F NO FM APPROVALS 5 HORIZONTAL SIDEWALL cULus LISTED FOR DEFLECTOR 4"TO 12"BELOW THE CEILING, ALL:ALL HAZARDS FM APPROVED 4"TO 6"BELOW THE CEILING. OH:ORDINARY HAZARD LH:LIGHT HAZARD °INSTALL IN ACCORDANCE TO BS5306 AND ANY OTHER RELATED DOCUMENTS. 11/2"NPT 1 PENDENT VERTICAL SIDEWALL 6'MIN.SPACING. =UPRIGHT VERTICAL SIDEWALL UL 9'MIN.SPACING. �x ,A, 500°F AVAILABLE UPON REQUEST WITH NO APPROVALS. GLOBE- PRODUCT I I ARRANTY ORDERING INFORMATION Globe agrees to repair or replace any of its own SPECIFY manufactured products found to be defective in material •Quantity Model Number Style or workmanship for a period of one year from date of •Orifice • Thread Sizes • Temperature • Finishes desired shipment. •Quantity-Wrenches-P/N 325390(1/2"); P/N 312366(3/4") For specific details of our warranty, please refer to Price List Terms and Conditions of Sale(Our Price List). GIL BE 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com JULY 2012 PRINTED U.S.A. BULLETIN GL5661, REV.#5 EXTENDED COVERAGE BE� ORDINARY HAZARD AUTOMATIC SPRINKLERS FIRE SPRINKLER CORPORATION MODELS GL 1121 & GL1113 UPRIGHT •PENDENT RECESSED PENDENT DESCRIPTION AND OPERATION The Globe GL Series Extended Coverage Ordinary Hazard Extra Large Orifice Sprinkler is a low profile yet durable design which utilizes a 3mm frangible glass ampule as the thermosensitive element. While the sprinkler provides an aesthetically pleasing appearance, it serves to protect various 011A areas of coverage. This sprinkler series is available in various styles, temperature ratings and several finishes to meet many varying design requirements. The Globe GL Series Extended Coverage Ordinary Hazard Extra Large Orifice Sprinkler is to be installed per NFPA 13 guidelines. The heart of Globe's GL Series sprinkler proven actuat- ing assembly is a hermetically sealed frangible glass ampule EXTENDED COVERAGE that contains a precisely measured amount of fluid. When heat ORDINARY HAZARD is absorbed, the liquid within the bulb expands increasing the UPRIGHT internal pressure. At the prescribed temperature the internal GL1121 pressure within the ampule exceeds the strength of the glass causing the glass to shatter. This results in water discharge which is distributed in an approved pattern depending upon the deflector style used. _AMR • TECHNICAL DATA %NO' •See reverse side for Approvals and Specifications. _ •Temperature Ratings- _ - c 155°F (68°C), 175°F (79°C), 200°F (93°C), 286°F (141°C) EXTENDED COVERAGE 'Water Working Pressure Rating - 175 psi (12 Bars) ORDINARY HAZARD •Factory tested hydrostatically to 500 psi (34 Bars) PENDENT•RECESSED PENDENT •Maximum low temperature glass bulb rating is -67°F (-55°C) GL1113 •Frame - bronze •Deflector- brass •Screw- brass •Bulb seat- copper •Spring - nickel alloy• Seal -teflon •Bulb - glass with alcohol based solution, 3mm size •Escutcheon Assembly-steel •SPRINKL ER TEMPERATURE RATING/CLAS S1FlCATION and COLOR CODING CLASSIFICATION AVAILABLE SPRINKLER BULB COLOR N.F.P.A. MAXIMUM CEILING TEMPERATURES TEMPERATURE ORDINARY RED INTERMEDIATE YELLOW/GREEN HIGH BLUE NOVEMBER 2013 A-79 BULLETIN GL1113,REV.# EXTENDED COVERAGE • ORDINARY HAZARD EXTRA LARGE ORIFICE AUTOMATIC SPRINKLERS MODELS GL1121 & GL1113 UPRIGHT PENDENT •PENDENT RECESSED SPECIFICATIONS AND APPROVALS NOMINAL THREAD SIZE LENGTH FINISHES cULus "K"FACTOR Factory Bronze 11.2 (160 metric) 3/4"NPT (20mm) 2 7/16" (6.2cm) Chrome X White Polyester' Black Polyester" NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. A. 'AVAILABLE AS cULus LISTED CORROSION RESISTANT WHEN SPECIFIED ON ORDER. `V CULus LISTING DESIGN - USE REQUIREMENTS FOR ORDINARY HAZARD ONLY TEMPERATURE MAX.AREA OF ORDINARY GROUP 1 ORDINARY GROUP 2 RESPONSE SIN STYLE 155°F 175°F 200°F 286°F COVERAGE MIN. MIN. MIN. MIN. MODEL (68°C) (79°C) (93°C) (141°C LENGTH x WIDTH PRESSURE FLOW PRESSURE FLOW Fear(MehrsJ (bars) G.P.N.(I/min.) P.3.1.(bars) G.P.M.(GAWP.) GL1121 UPRIGHT QUICK X — X — 14(4.3)x 14(4.3) 7(.48) 30(114) 12(.83) 39(148) RESPONSE GL1113 PENDENT RECESSED PENDENT GL1121 UPRIGHT 16(4.9)x 16(4.9) 12(.83) 39(148) 21(1.45) 51(193) STANDARD X X X X 18(5.5)x 18(5.5) 19(1.31) 49(185) 34(2.34) 65(246) RESPONSE PENDENT GL1113 RECESSED PENDENT 20(6.1)9 20(6.1) 29(2.0) 60(227) 51(3.52) 80(303) NOTE:METRIC CONVERSIONS ARE APPROXIMATE. SPRINKLERS SHALL BE LIMITED AS PER THE REQUIREMENTS OF NFPA13 AND ANY OTHER RELATED DOCUMENTS. FOR COVERAGE AREA DIMENSIONS LESS THAN OR BETWEEN THOSE INDICATED,USE THE MINIMUM FLOW FOR THE NEXT HIGHEST COVERAGE AREA FOR WHICH HYDRAULIC DESIGN CRITERIAARE STATED. MINIMUM DISTANCE BETWEEN UPRIGHT SPRINKLERS(GL1121)IS 11 FEET(3.4 METERS). MINIMUM DISTANCE BETWEEN PENDENT SPRINKLERS(GL1113)IS 9 FEET(2.7 METERS). 215/16'DIA. 2"DIA.MIN. IN CEILING 1 19/32'DIA. ORDERING INFORMATION 12 —I 1'x 3/4'REDUCER SPECIFY •Quantity•Model Number•Style •Orifice I Thread Size -Temperature•Finishes desired CUP �, __ •Quantity-Wrenches-P/N 333010 �6 - I •Quantity- Recessed Wrenches-P/N 333011 is I• 8: •MAX. lI .— GLOBE'PRODUCT WARRANTY CEILING tip 1'MIN. I/8" Globe agrees to repair or replace any of its own manufactured RETAINER 3H'MAx. products found to be defective in material or workmanship for a period of one year from date of shipment. For specific details of our warranty please refer to Price List CROSS SECTION Terms and Conditions of Sale(Our Price List). GLbBE4077 AIRPARK DRIVE,STANDISH,MICHIGAN 48658 qv. 989-846-4583 FAX 989-846-9231 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com NOVEMBER 2013 PRINTED U.S.A. BULLETIN GL1113,REV.# QUICK RESPONSE GL ® AUTOMATIC SPRINKLERS ® GL SERIES FIRE SPRINKLER CORPORATION DRY TYPE DESCRIPTION AND OPERATION The Globe Quick Response GL Series Dry Type Pendent Sprinkler is designed for use in special applications such as freezing environments and conditions where sediment or foreign materials might accumulate in ordinary drop nipples. The Globe Quick Response GL Series Dry Type Pendent Sprinkler utilizes a 3mm frangible glass ampule as the thermosensitive element. This provides sprinkler operation ap- proximately six times faster than ordinary sprinklers. At the .:: ; ampule's rated temperature, the sprinkler opens releasing the bulb seat, causing the inner tube assembly to move, allowing the spring assembly to pivot alongside the inner tube. At this time, . „ ._ __ water flows through the sprinkler and is distributed by the deflector -: ' in an approved discharge pattern. It can be installed wherever ! 4 PR - t '• standard spray sprinklers are specified but offers the additional feature of greatly increased safety to life. Quick Response Sprinklers should be used advisedly and under the direction of approving authorities having jurisdiction. SURFACE SLEEVE The heart of Globe's Model GL Series sprinkler proven actu MouNT &SKIRT ating assembly is a hermetically sealed frangible glass ampule that contains a precisely measured amount of fluid. When heat is absorbed, the liquid within the bulb expands increasing the internal pressure. At the prescribed temperature the internal pressure within the ampule exceeds the strength of the glass i ;r causing the glass to shatter. This results in water discharge which is distributed in an approved pattern. TECHNICAL DATA I • See reverse side for Approvals and Specifications • Temperature Ratings - 135°F (57°C), 155°F (68°C), 175°F `" - (79°C), 200°F (93°C), 286°F (141°C) i "iiir- •Water Working Pressure Rating - 175 psi (12 Bars) i --" • Factory tested hydrostatically to 500 psi (34 Bars) F� � • Maximum low temperature glass bulb rating is -67°F (-55°C) • Frame - bronze• Deflector- brass • Screw- brass • Bulb EXTENDED RECESSED seat - brass •Spring - teflon coated nickel alloy• Retainer - brass • Pin - stainless steel *Torsion spring - stainless steel • Bulb - glass with alcohol based solution, 3mm• Orifice insert - brass•3/4" NPT or 1" NPT•Outer tube - galvanized steel pipe •Inner tube stainless steel •SPRINKLER TEMPERATURE RATING/CLASSIFICATION and COLOR CODING CLASSIFICATION AVAILABLE BULB N.F.P.A. MAXIMUM SPRINKLER TEMPERATURES COLOR CEILING TEMPERATURE ORDINARY 135°F/155°F 57'C/68°C ORANGE/RED 100°F 38°C INTERMEDIATE 175°F/200°F 79°C/93°C YELLOW/GREEN 150°F 66°C HIGH 286°F 141°C BLUE 225`F 107°C 4077 AIRPARK DRIVE, STANDISH, MICHIGAN 48658 989-846-4583 • FAX 989-846-9231 JULY 2010 A-55 BULLETIN GL5635, REV.#13 QUICK RESPONSE " AUTOMATIC SPRINKLERS GL SERIES DRY TYPE SPECIFICATIONS NOMINAL"K" FACTOR THREAD SIZE LENGTH FINISHES cULus Variable Factory Bronze 5.6 (80 metric) 3/4"or 1"NPT to 48" Satin Chromes Bright Chrome White Polyester FM Variable to 8.1 (116 metric) 1"NPT 36„ Black Polyester Lead Coated2 NOTE: METRIC CONVERSIONS ARE APPROXIMATE. 'FINISHES AVAILABLE ON SPECIAL ORDER. cULus LISTED CORROSION RESISTANT: POLYESTER MUST BE SPECIFIED ON ORDER. 'LEAD COATED IS UL APPROVED ONLY. V APPROVALS STYLE SIN MODEL KFACTOR THREAD SITE 135°F 155°F 175°F 200°F 286°F .Fm cULus NYC-DOBMEA 57°C 68°C 79°C 93°C 141°C 101-92-E GL5635 5.6 1"NPT X X X X X X X X PENDENT GL5636 5.6 3/4"NPT X X X X X - X X GL8135 8.1 1"NPT X X X X X - X X RECESSED GL5635 5.6 1"NPT X X X X X X X X PENDENT GL5636 5.6 3/4"NPT X X X X X - X X GL8135 8.1 1"NPT X X X X X - X _ X NOTE: LISTED FOR ALL HAZARDS "PENDENT STYLE-FM APPROVED 155°F,200°F,AND 286°F `RECESSED PENDENT STYLE-FM APPROVED 155°F AND 200°F IMPORTANT INSTALLATION DATA Globe GL Series Dry Pendent sprinklers should be installed in CROSS SECT IONS accordance with the requirements set forth in NFPA 13. These sprinklers are to be installed using a pipe wrench applied to the outer tube. When this is not possible,the proper sprinkler head wrench o,E^ °) ' ., •,,. ^ ,n-' T " maybe used with extreme care for lengths up to approximately 18". " Excessive force may distort the frame thus destroying the unit. I° ?a m � r When installed in a wet system extending Into a freezing ,. area see chart on Dry Caution Sheet for minimum exposed ;;.r.'1:Z: - barrel length to prevent ice plugs. Please refer to our D r.o, "�`""" 9 P P 9 Dry VIM Viff "i'' r Caution sheet for further important installation data. "' -] r-„ ,.CU"° ORDERING INFORMATION ° "w,�" ;� _ . N;:r, T ' 1 SPECIFY iii' ; • Quantity* Model Number•Style•Orifice + "°'� _1 • Temperature • Finishes desired EXTENDED PENDENT PENDENT • Quantity-Wrenches-P/N 333010 .,•,F `>>z,�_ ^” err Quantity- Recessed Wrenches- P/N 337014 7 ■ ,44- •• Quantity-Protective Caps-P/N 327109-cap(Friction Fit Recessed) • Escutcheons desired ;_"�°'"n 1 °° " • "A" Dimension-Distance from face of fitting to the finished �_ ceiling line regardless of escutcheon used -1 1-Z" ,°E,°s GLOBE® PRODUCT WARRANTY I ,A; j�l I� „°,^°^" ' ' Globe agrees to repair or replace any of its own manufac- tured tured products found to be defective in material or workman- ship for a period of one year from date of shipment. RECESSED PENDENT SLEEVE&SKIRT PENDENT For Specific details of our warranty, please refer to Price List Terms and Conditions of Sale (Our Price List). GL ® $E 989 846-45gRK DRIVE,STANDISH,FAX 989-846-92318 FIRE SPRINKLER CORPORATION 1-800-248-0278 www.globesprinkler.com JULY2010 PRINTEDU.S.A. BULLETIN GL5635,REV.#13 two Worldwide Fire Protection Contacts www'tyco-fire.com Products Model SW-20 and SW-24 — 11.2 K-factor Extended Coverage Ordinary Hazard Horizontal Sidewall Sprinklers (Standard Response) General rosive atmospheres. Consequently, it is recommended that the end user be f . Description consulted with respect to the suitability ,� P of these corrosion resistant coatings for The TYCO Model SW-20 and SW-24, any given corrosive environment.The .fl 11.2 K-factor,Extended Coverage Ordi- effects of ambient temperature, con- :,, nary Hazard(ECOH)Horizontal Sidewall centration of chemicals,and gas/chemi- Sprinklers,Standard Response are dec- cal velocity,should be considered,as a orative glass bulb sprinklers designed minimum,along with the corrosive na- SW-20 for use in ordinary hazard occupancies ture of the chemical to which the sprin- , per NFPA 13. klers will be exposed. The SW-20 provides protection of coy- NOTICE ^` erage areas up to 16 ft. x 20 ft. (320 The Model SW-20 and SW-24 S rm ft2) whereas the SW-24 provides pro- klers described herein must be installed tection of coverage areas up to 16 ft.x 24 ft.(384 ft2),as compared to standard and maintained in compliance with this , ^� 43ri■, coverage horizontal sidewall sprinklers document and with the applicable stas- i ' having a maximum coverage area of 10 dards of the National Fire Protection As- ft.x 10 ft.(100 ft2)for ordinary hazard sociation, in addition to the standards ft.x ft.(100 of any authorities having jurisdiction. SW-24 occupancies. Failure to do so may impair the perfor- Horizontal sidewall sprinklers are de- mance of these devices. Maximum Working Pressure signed for installation along a wall or The owner is responsible for maintain- 175 psi(12,1 bar) the side of a beam and are common- ing their fire protection system and de- ly used instead of pendent or upright vices in proper operating condition. The Discharge Coefficient sprinklers due to aesthetics or building instal ling contractor or sprinkler manu- K= 11.2 GPM/psi1/2(161,3 LPM/bar1l2) construction considerations,where pip- facturer should be contacted with any ing across the ceiling is not desirable. questions. Temperature Rating Corrosion resistant coatings, where SW-24: 00°F((689 °C)&200°F(93°C) 2 applicable, are utilized to extend the sprinkler SW-24:200°F(993 3°C) life of copper alloy sprinklers beyond Finishes that which would otherwise be ob- Identification Refer to Table B tained when exposed to corrosive at- mospheres.Although corrosion resis- Number (SIN) Physical Characteristics: tant coated sprinklers have passed the Frame Bronze standard corrosion tests of the appli- TY5332-SW-20 Button Bronze cable approval agencies,the testing is TY5337-SW-24 Sealing Assembly Beryllium Nickel w/TEFLON not representative of all possible cor- TY5332 is a re-designation for C5332 Bulb Glass TY5337 is a re-designation for C5337 Compression Screw Brass Technical Deflector Bronze Data IMPORTANT I Approvals UL and C-UL Listed Always refer to Technical Data Sheet TFP700 for the "INSTALLER (Refer to the Design Criteria Section) WARNING"that provides cautions Polyester coated sprinklers are UL and with respect to handling and instal- C-UL Listed as Corrosion Resistant lation of sprinkler systems and corn- Sprinklers ponents.Improper handling and in- NYC under MEA 177-03-E stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Page 1 of 6 MARCH 2014 TFP230 TFP230 Page 2 of 6 • Components: 6* 5 J WRENCH 1 - Frame V ( — RECESS 2- Button ,;�'�0`t1.'�to (END"B") 3- Bulb APPLY 4- Compression Screw 0 l', �ii:., WRENCH AS 5- Sealing Assembly� %A SHOWN 6- Deflector* \ \®�s • INV *Temperature rating is 4 3 2 1 n indicated on Deflector. **Pipe thread connections per ISO 7-1 can be provided CENTERLINE FIGURE 3 1/2" OF SPRINKLER WRENCH W-TYPE 3 SPRINKLER on special request. WRENCH (12,7 mm) WATERWAY FLAT / NPT 1 NPT 1��I t rilL.' MAX ow 111111°` II I 2„ 1/2"(12,7 mm) / (50,8 mm) NOMINAL — j MAKE-IN 6'(152,4 mm) 3/4" 2-3/8" TO 12"(304,8 mm) (19,1 mm) (60,3 mm) CEILING TO TOP 4/12 FIGURE 1 OF SPRINKLER SLOPE MODEL SW-20(TY5332) DEFLECTOR MAXIMUM r" EXTENDED COVERAGE ORDINARY HAZARD DISTANCE HORIZONTAL SIDEWALL SPRINKLER FIGURE 4 11.2 K-FACTOR,3/4 INCH NPT SPRINKLER PLACEMENT UNDER SLOPED CEILINGS IN Components: LOADING DOCKS 1 - Brame 2 ..** g 3/4 Operation 2- Button 4- Bulb The lass bulb contains a fluid that ex- 4- Compression Screw Q tlill 5 Sealing Assembly pands when exposed to heat.When the 6- Deflector* \ rated temperature is reached,the fluid * expands sufficiently to shatter the glass Temperature rating is NPT bulb,allowing the sprinkler to activate indicated on Deflector. WRENCH and water to flow. FLAT **Pipe thread connections per ISO 7-1 can be provided CENTERLINE on special request. 9/16° OF SPRINKLER (14,33 WATERWAY 1 5 2 Q. I de, 4 3 �i811M W L. 2„ 1 1/2"(12,7 mm) (50,8 mm) NOMINAL f MAKE-IN 3/4" _ 2-3/8" (19,1 mm) (60,3 mm) FIGURE 2 MODEL SW-24(TY5337) EXTENDED COVERAGE ORDINARY HAZARD HORIZONTAL SIDEWALL SPRINKLER 11.2 K-FACTOR,3/4 INCH NPT TFP230 Page 3 of 6 • MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 1(0.15 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Areani, Flow(2), Pressure(2), Distance), Temperature Spacingl4l, Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 16(4,9 x 4,9 38(144) 11.5(0,79) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 18(4,9 x 5,5) 43(163) 14.7(1,01) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 20(4,9 x 6,1) 48(182) 18.4(1,27) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-20 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5332) OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum p Areani, Flow(2), Pressurel2), Distancet3), Temperature Spacing(^l, Rating Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,CF Ft.(m) Standard 16 x 16(4,9 x 4,9 51 (193) 20.7(1,43) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 18(4,9 x 5,5) 58(220) 26.8(1,85) 6 to 12(150 to 300) 155,200 8(2,4) Standard 16 x 20(4,9 x 6,1) 64(242) 32.7(2,25) 6 to 12(150 to 300) 155,200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) OH Group 1 (0.15 gpm/sq.ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Arean), Flow(2), Pressure), Distance ), Temperature Spacingt4), Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 22(4,9 x 6,7) 53(200) 22.4(1,54) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 58(220) 26.8(1,85) 6 to 12(150 to 300) 200 8(2,4) MODEL SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLER(TY5337) OH Group 2(0.20 gpm/sq.-ft.) Response Coverage Minimum Minimum Deflector-To-Ceiling Sprinkler Minimum Rating Areal'), Flow(zl, Pressure), Distance), Temperature Spacing(41, Ft.x Ft.(m x m) GPM(LPM) PSI(BAR) In.(mm) Rating,°F Ft.(m) Standard 16 x 22(4,9 x 6,7) 71 (269) 40.2(2,77) 6 to 12(150 to 300) 200 8(2,4) Standard 16 x 24(4,9 x 7,3) 77(291) 47,3(3,26) , 6 to 12(150 to 300) 200 8(2,4) NOTES 1.Backwall(where sprinkler is located)by sidewall(length of throw). 2.Requirement is based on minimum flow in GPM from each sprinkler.The indicted residual pressures are based on the nominal K-factor. 3.The centerline of the sprinkler waterway is located below the deflector as shown in Figures 1 and 2. 4.Minimum spacing is for lateral distance between sprinklers located along a single wall.Otherwise adjacent sprinklers(i.e., sidewall sprinklers on an adjacent wall,on an opposite wall,or pendent sprinklers)must be located outside of the maxi- mum listed protection area of the extended coverage sidewall sprinkler being utilized. TABLE A UL AND C-UL LISTING COVERAGE AND FLOW RATE CRITERIA • TFP230 Page 4 of 6 Design Step 2.With pipe thread sealant ap- Frequent visual inspections are recom- plied to the pipe threads, hand tighten mended to be initially performed for Criteria the sprinkler into the sprinkler fitting. corrosion resistant coated sprinklers, Step 3.Tighten the sprinkler into the after the installation has been complet- The TYCO Model SW-20 and SW-24, sprinkler fitting using only the W-Type ed,to verify the integrity of the corro- 11.2 K-factor,Extended Coverage Ordi- 3(End B)Sprinkler Wrench(Ref. Fig- sion resistant coating.Thereafter,an- nary Hazard(ECOH)Horizontal Sidewall ure 3).With reference to Figures 1 and nual inspections per NFPA 25 should Sprinklers are for use in ordinary haz- 2,the W-Type 3 Sprinkler Wrench is to suffice;however,instead of inspecting and occupancies with non-combustible be applied to the sprinkler wrench flats from the floor level,a random sampling unobstructed construction and with a of close-up visual inspections should ceiling slope not exceeding 2 inches be made,so as to better determine the per foot(9.2°), using the design crite- Care and exact sprinkler condition and the long ria provided in Table A,(as well as any term integrity of the corrosion resistant additional requirements specified in Maintenance coating as it may be affected by the cor- NFPA 13 for Extended Coverage Side- rosive conditions present. wall Spray Sprinklers). The TYCO Model SW-20 and SW-24, 11.2 K-factor,Extended Coverage Ordi- A 36 inch (914 mm) clearance must nary Hazard(ECOH)Horizontal Sidewall Limited be maintained between the top of the Sprinklers must be maintained and ser- Warranty sprinkler deflector and any miscella- viced in accordance with this section. neous storage. Before closing a fire protection system For warranty terms and conditions,visit The SW-20 and SW-24 may be installed main control valve for maintenance work www.tyco-fire.com. on sloped ceilings in loading docks with on the fire protection system that it Ion- a maximum roof slope of 4 inches per trols,obtain permission to shut down the foot(18.4°)as shown in Figure 4 and affected fire protection system from the using the design criteria provided in proper authorities and notify all person- Table A. nel who may be affected by this action. The SW-20 and SW-24 can be used only The owner is responsible for the in- for exposed applications.The SW-20 spection,testing,and maintenance of and SW-24 cannot be recessed. their fire protection system and devices in compliance with this document,as Installation well as with the applicable standards of the National Fire Protection Associa- The TYCO Model SW-20 and SW-24, tion(e.g., NFPA 25), in addition to the 11.2 K-factor,Extended Coverage Ordi- standards of any other authorities hav- nary Hazard(ECOH)Horizontal Sidewall Ing jurisdiction.Contact the installing Sprinklers must be installed in accor- contractor or sprinkler manufacturer re- dance with this section. garding any questions. General Instructions Automatic sprinkler systems should be Do not install any bulb type sprinkler if inspected,tested,and maintained by a the bulb is cracked or there is a loss qualified Inspection Service in accor- of liquid from the bulb.With the sprin- dance with local requirements and/or kler held horizontally,a small air bubble national code. should be present.The diameter of the Absence of an escutcheon, which is air bubble is approximately 1/16 in.(1,6 used to cover a clearance hole, may mm). delay the time to sprinkler operation in A leak tight 1/2 inch NPT sprinkler joint a fire situation. should be obtained with a minimum Automatic sprinklers must never be to maximum torque of 7 to 14 ft.-lbs. painted, plated, coated or otherwise (9,5 to 19,0 Nm).Higher levels of torque altered after leaving the factory. Modi- can distort the sprinkler Inlet with con- fied sprinklers must be replaced.Sprin- sequent leakage or impairment of the klers that have been exposed to corro- sprinkler. sive products of combustion,but have Do not attempt to compensate for in- not operated,should be replaced if they sufficient adjustment in the Sprinkler by cannot be completely cleaned by wiping under-or over-tightening the Sprinkler/ the sprinkler with a cloth or by brushing Support Cup Assembly. Re-adjust the it with a soft bristle brush. position of the sprinkler fitting to suit. Care must be exercised to avoid dam- Step 1.Horizontal sidewall sprinklers age to the sprinklers before,during,and are to be installed with their center- after installation. Sprinklers damaged line perpendicular to the back wall and by dropping, striking, wrench twist/ parallel to the ceiling.The word"TOP" slippage,or the like, must be replaced. on the deflector is to face towards the Also,replace any sprinkler that has a ceiling. cracked bulb or that has lost liquid from its bulb.(Ref. Installation Section). TFP230 Page 5 of 6 P/N 51 - XXX - X - XXX I I SPRINKLER SPRINKLER MODEL SIN FINISH TEMPERATURE RATING 072 Model SW-20 TY5332 1 Natural Brass 155 155°F(68°C) (SW-20 Only 073 Model SW-24 TY5337 4 Signal White(RAL9003) 200 200°F(93°C) Polyester (SW-20 or SW-24) 9 Chrome Plated TABLE B PART NUMBER SELECTION MODEL SW-20 AND SW-24 ECOH HORIZONTAL SIDEWALL SPRINKLERS WITH 3/4 INCH NPT CONNECTION Ordering Procedure Contact your local distributor for avail- ability.When placing an order, indicate the full product name and Part Num- bers(P/N). Sprinkler Assemblies with NPT Thread Connections: Specify: Model (specify) ECOH Hori- zontal Sidewall Sprinkler,SIN(specify), (specify)temperature rating, (specify) finish,P/N(specify from Table B) Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, P/N 56-895-1-001 TFP23O Page 6 of 6 GLOBAL HEADQUARTERS 1 1400 Pennbrook Parkway,Lansdale,PA 194461 Telephone+1-215-362-0700 Copyright©2014 Tyco Fire Products,LP. All rights reserved. Vico TEFLON is trademark of The DuPont Corporation Fire Protection Products FLEXHEAD FRICTION LOSS DATA AND SPECIFICATIONS Maximum Equivalent Maximum Rated Outlet Hose Maximum Internal Maximum Length of Schedule 40, Pressure FlexHead Orifice Assembly Ambient Maximum I.D. Length Number of Nomirral1in.Diameter p psi kPa K-factor Model# in Size gth 90-degree Bends Pipe,ft Temperature P ( )/psi(kPa) in(cm) ft(cm) FM UL Rating F(C) Standard H-Series 2024,2024H 1 1/2(1.27) 2(0.6) 3 18 4 11 300°(1489 175(1205)/300(2068) : 5.62 2036,2036H 1 1/2(127) 3(0.9) 3 26 6 16 300°(148°) 175(1205)/300(2068) 5.62 2048,2048H 1 1/2(1 27) 4(1 2) 4 30.3 24 , 300°(148 9 175(1205)/300(2068) 5.62 2060,2060H 1 1/2(1 27) 5(1.5) 4 I 35.8 29 300°(148°) 175(1205)/300(2068) 5.62 2072,2072H 1 1/2(1 27) 6(1.8) 4 45.6 35 300°(148°) 175(1205)/300(2068) 5.62 2024 75,2024H 75 1 3/4(1.90) 2(0.6) 3 14.7 12 300°048°) 175(1205)/300(2068) 14.0 2036 75,2036H 75 1 3/4(1 90) 3(0.9) 3 21.8 18 300°(148°) 175(1205)/300(2068) 14.0 2048 75,2048H 75 1 " 3/4(1,90) 4(1.2) 4 29 0 23 300°0489 175(1205)/300(2068) 14.0 2060 75,2060H 75 1 3/4(1.90) 5(1.5) i 4 361 29 300'0489 175(1205)/300(2068) 14.0 2072 75,2072H 75 1 3/4(1 90) 6(18) 4 43.2 32 3000(148°) 175(1205)/300(2068) 14 0 ', 175psi,300psi i.. 2024E,2024HE 1 1/2(1.27) 2(0.6) 3 26 4,14 7 19 300°(148°) 175(1205)/300)2068) ' 5.62 2036E,2036HE 1 ) 1/2(127) 3(0.9) 3 30.1,21.8 23 300°(148°) 175(1205)/300(2068) 5.62 2048E,2048HE 1 1/2(1 27) 4(1.2) 4 33.8,29.0 , 27 300°(148°) 175(1205)/300(2068) 5.62 2060E,2060HE 1 1/2(127) 5(1.5) 4 37.5,36.1 32 300°1148') 175(1205)/300(2068) 5.62 2072E,2072HE 1 1/2(1.27) 6(1.8) 4 41.2,43.2 � 35 300°(148 0) 175(1205)/300(2068) I 5.62 2024E 75,2024HE 75 1 3/4(1.90) 2(0.6) 3 14.7 18 300°0481 175(1205)/300(2068) : 14.0 2036E 75,2036HE 75 ! 1 3/4(1.90) 3(0.9) 3 21.8 23 300'0489 175(1205)/300(2068) 14.0 2048E 75,2048HE 75 1 3/4(1.90) 4(12) 4 29.0 I 23 300°(148°) 175(1205)/300(2068) 14.0 2060E 75,2060HE 75 1 3/4(1 90) 5(1.5) 4 36.1 29 300°0481 175(1205)/300(2068) 14.0 2072E 75,2072HE 75 1 3/4(1.90) 6(1.8) 4 43,2 32 300°0481 175(1205(/300(2068) 14.0 2036F 1.25 1/2(5.6) 3(0.9) 3 16.0 300°(148 1 175(1205)/300(2068) '' 5.62 2048F 1.25 1/2(5.6) 4(1.2) : 4 19.6 300°048 1 175(1205(/300(2068) 5.62 2072F 1.25 1/2(5.6) 6(1.8) 4 22.8 300 11489 175(1205)/300(2068) 5.62 2036E75 1.25 3/4(14) 3(0.9) 3 9.3 300°(148°) 175(1205) 14.0 2048F75 125 3/4(14) 4(12) 4 11.4 300°(148 9 175(1205) 14.0 2072575 125 3/4(14) 6(1.8) 4 15 300'(148°) 175(1205) 14.0 2036F100 125 1(14) 3(0.9) 3 7.1 300'(148 9 175(1205) 22.4 2048E100 125 1(14) 4(12) 4 6.3 300°(148°) 175(1205) 22.4 2072F100 i 1.25 1(14) 6(1.8) , 4 10.1 300'(148°) 175(1205) 22.4 Dv Model Numbers:The"H"designates high pressure unit rated to 300 prig and the"E"designates elbow style unit. The"F"designates high flow rate using 1 1/4"internal hose diameter. > LE, HEA FlexHead products are intended for use in hydraulically designed wet,pre-action,deluge or dry pipe I N D (/ S T R I E S"-∎'' sprinkler connections per NFPA 13,13R,and 13D guidelines.The hydraulic loss of the FlexHead connector needs to be included in the hydraulic design calculations the same as a valve or fitting.Each FlexHead sprinkler drop has a 3"minimum bend radius per UL guide lines,and a 8"minimum bend radius per q PART o anatkore FM guidelines. I F I MI,:I L.i t "FM Equivalent Length Numbers include maximum "K"factor sprinkler head that is listed." 56 Lowland Street, Holliston, MA 01746 'Equivalent lengths are shown with maximum number of 90 degree bends at the minimum bend-radius.Different Toll-Free 800-829-6975 • Fax 508-893-6020 values were obtained by FM and UL due to the differences in minimum bend radius,testing protocol and calculation methods.Please see individual testing standards for more information relative to friction loss (Equivalent Length of Pipe). www.flexhead.com ©2013 Atkore International, Inc.All rights reserved. FXH-L-8040-1306 IPS CARBON STEEL PIPE FIRE PROTECTION VALVES • FireLock® Butterfly Valve c UL . ® `VdS LPCB cTP LIMO 104404 SERIES 705 __--- --._ WITH WEATHERPROOF ACTUATOR The Series 705 Butterfly Valve features a weatherproof actuator housing Approved for indoor or outdoor use,a ductile iron body and disc with EPDM seats.Designed for fire 1 i protection services only Victaulic FireLock Series 705 Butterfly Valve is cULus Listed, LPCB Listed, FM and VdS Approved for 300 psi/2068 kPa service.Contact Victaulic for details of agency approvals. Ii APPROVALS AND LISTINGS Approval/Listing Service Prev.nrr Series 705 Butterfly J,..a:• cULus L FM i. Ve5 1 LPCO 2750mm up to 300poi/2068kPa n/a up to300psI/2068kPa up to 300psV2068kPa 2 I/2765mrn up to 300pV/2068kPa up to 300psi/2068kPa n/a up to 300psi/2068kPa /61 nun up to 300psi'20681,Pa up to 300psi/2068kPa up to 300psi/2068kPa up to 300psi/2068kPa 3180m n up to 300p3i 12068kPa up to 300psi/2068kPa up to 300ps1206SkPa up to 300psi/2068kPa 4"/ICOrrm up to 300p312068kPa up to 300ps1/2068kPa up to 300ps120.6.8kPa up to 300psi/2068kPa 5'/12mm up to 300psi/2068kPa up to 300psi/2068kPa c/a up to 300ps1/2068kPa 139.7rnrn up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps1/2D68kPa up to 300psr/2068kPa 67150mm up to 300psi/2068kPa up to 300psi/2068kPa up to 300ps12068tPa up to 300psI/2068kPa 165.lrnnt up to 3O0ps12068kPa up to 300psi/2068kPa n/A op to 300psi/2068kPa 8 "VOOnun up 12 30opsi/2068kPa up to 300psi/2068kPa up to 300ps12068kPa up to 300psi/2068kPa 107251Tm up to 300ps1/2068kPa up to 300psi/2068kPa a n/a up to 300psi/2068kPa 12Y300rnm a to 300.s1/2068kPa u to 300•si2068kPa n/a u•to 300 si2068kPa JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com _` otau'ie VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY O 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. V REV_E 10.81_1 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 1 0.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR MATERIAL SPECIFICATIONS Body:Ductile iron conforming to ASTM A-536,grade 65-45-12 End Face,2—6"/50—150 mm:Ductile iron conforming to ASTM A-536,grade 65-45-12 Seal Retainer,8—127200—300mm: Ductile iron conforming to ASTM A-536,grade 65-45-12 Coating:Black alkyd enamel Disc:Ductile iron conforming to ASTM A-536,grade 65-45-12,with electroless nickel coating con- forming to ASTM B-733 Seat: • Grade"E"EPDM Stems:416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge:C36000 brass Bearings:Stainless Steel with TFE lining Stem Seals:EPDM Stem Retaining Ring:Carbon steel Actuator: • 2-8750-200mm: Brass or bronze traveling nut on a steel lead screw,in a ductile iron housing • 10-127250-300mm:Steel worm and cast iron quadrant gear,in a cast iron housing www.victaulic.com lctaullc VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY C 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.81 2 • IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR DIMENSIONS- Sac Dirnemiuns-In cheirmiiiimters II 1 Outside End to Size Diameter End A B C D E F G DIA H 1 2' 2.375 425 228 641 400 422 450 2.12 I�� 603 mm 60.3 1080 579 1628 1016 1072 1143 53.8 2h 2875 377 4444{{ 228 754 400 422 450 1.77 im 73 mm f 73.0 958 579 1915 1016 10.2 1143 45.0 • 3000 377 778 754 400 422 450 177 76.1 mm 1 76.1 95 8 57.9 191 5 101.6 107.2 114 3 45.0 F 3' 3.500 3.77 2.53 7.79 4.50 4.22 4.50 1.77 G 88.9mm 88.9 i 95.8 64.3 19/9 - - 1143 1077 114.3 45.0 1 4.250 4.63 288 88 550 422 450 ( 2.20 108 mm 1 1080 I 117.6 73.2 223.8 139.7 1072 114.3 55.9 4' 4.500 4.63 288 88' 550 4.22 450 ( 220 ��T�� 1143m4 114.3 117.6 7i2 223 1397 107.7 1143 ) 55.9 m�� OH 5253 583 335 110% 656 6.19 630 258 ��nli� 133mm 133.0 1494 ' 85.1 276.4 1666 1572 160.0 65.5._ 111 5500 5.83 3.35 10.88 656 6.19 6.30 1.58 1391 mm, 134/ 1444 851 276 1606 1572 1600 55.6 'III 5' 5.569 584 395 1288 656 619 6.30 2.58 141.3 mm 1413 1444 851 276.4 1666 1572 1600 655 11'I�!I m 6.250 584 3.84 1198 04' 751 6.19 630 258 B ...'1___,,...'' 159 mm 1590 1494 975 289 04 1910 1572 1600 65.5 6.500 588 384 11.33 04 752 6.19 6.30 2.58 1^ 165.1 mm 165.1 1494 975 239: - '04 191.0 1512 160.0 65.5 E A .-D - .... 61 6625 5.88 3.84 11.38 04' 752 614 6.30 1.90 Note:Optional W/15mm tap available. 1683 1663 1494 975 289. '04 191.0 1.57.2 1600 48.3 Contact Victaulic for details. a' 8.625 5.33 5.07 1353 . 030 1 47 10.00 6.19 8.10 2.33 219.1 mm 219.1 1354 128.8 345.6 20.3 3/3 2540 1572 2057 . 59.2 10" 10.750 640 537 1564 : 141 181 1 1225 8.10 9 C ?..... 273mm 273.0 162.6 161.8 3973 358 46.0 ''. 311.2 205.7 7786 12' 12.750 6.50 I 7.36 16.64 2.30 2.80 14.25 8.10 9.00 _ 323.9 mm 323.9 165.1 I 186.9 422.7 58.4 ! 71.1 362.0 ' 205.7 228.6 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ictaUliC° REV_E 10.81_3 IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 1 0.81 • FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 705 Butterfly Valve in equivalent feet/ meters of straight pipe. Size Size Actual Actual Nominal Outside Nominal Outside I Size Diameter Equiv. Site Diameter I Equiv. Inches Inches Feet/m Inches Inches I Feel/m mm mm of Pipe mm mm I of Pipe 2 2.375 6 6 6.625 14 50 60.3 1.8 150 168.3 4.2 65 73.0 1g 159 mm 159 mm 43 76.1 mm 3.000 6 165.1 mm 6.509 14 76.1 1.8 165.1 4.2 3 3.500 7 8 8.625 16 80 88.9 2.1 200 219.1 4.9 4 4.500 8 10 10.750 18 100 114.3 2.4 250 273.0 5.5 _.. __. .. 8 12 122 750 19 108 mm 108 mm 24 300 323.9 5.8 5 5.563 12 175 141.3 3.7 133 mm 133 mm I 12 3.7 139.7 mm 5.500 '. 12 139.7 3.7 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY ed 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. ,It+tr` Jl.c 10.81_4 REV_E IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR PERFORMANCE Cv values for flow of water at+60°F/+16°C with a fully open valve are shown in the table below. For additional details,contact Victaulic. Formulas for Cv Values: AP = Q2 Where: C a Q=Flow(GPM) AP=Pressure Drop(psi) Q = c x AP Cv=Flow Coefficient I I S ee Size C., Size C Actual Actual Actual 1 Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter Size Diameter Inches Inches Inches Inches Inches Inches mm min (Full Open, mm mm (Full Open) mm mm (Full Open) 2.375 170 5.563 1200 fl 8.625 2 3400 60.3 141.3 200 219.1 2 h 2.875 ...... _.... ...... 10 10.750 260 133 mm 1200 5800 65 730 250 273.0 76.1 mm 3.000 260 139.7 mm 5.500 1200 2 12.750 9000 76.1 139.7 300 323.9 3 3.500 6 6.625 80 88.9 i 440 150 168.3 1800 820 159 mm 159 mm 1800 4 4500 I 100 114.3 108 mm I 108 mm ! 820 1651 mm 6.500 1800 i 165.1 Formulas for Kv Values: AP = Q1 Where: IV Q=Flow CI) Q = K„ x AP AP=Pressure(bar) K =Flow Factor Size K;� Size K,, Size K.. Actual Actual Actual Nominal Outside Nominal Outside Nominal Outside Size Diameter Size Diameter Size Diameter Inches Inches Inches Inches Inches Inches mm mm (Full Open) mm elm (Full Open) men mm (Full Open) 2.375 5 5.563 8 8.625 2 60.3 147 125 I 141.3 1040 200 21)1 2940 21/2 2875 133mm 133mm 10 10./50 65 73.0 225 1040 250 2730 5020 76.1 mm 3000 225 139.7mm 5500 1040 12 17750 7790 761 1397 7 300 323.9 3 3 500 6 6 625 80 88.9 380 150 168.3 1560 4 4.500 710 159mm 159mm 1560 100 114.3 108 mm 108 mm 710 165)run 6 65 566 1560 • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. iCtaul.C' REV_E 10.81_5 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 10.81 + F - Lock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1.The supervisory switch contains two single pole,double throw,pre-wired switches. 2.Switches are rated: 10 amps 0 125 or 250 VACl60 Hz 0.50 amps 0 125 VDC 0.25 amps @ 250 VDC 3.Switches supervise the valve in the"OPEN"position. 4.One switch has two#18 insulated wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 insulated wire per termi- nal.This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm,in the area that the valve is installed. 5.A#14 insulated ground lead(green)is provided. Switch#1=Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices,per the authority having jurisdiction Normally Closed:(2)Blue Si Common:(2)Yellow Normally Closed:Blue with Orange Stripe S2 Normally Open: Brown with Orange Stripe Common:Yellow with Orange Stripe 11 ULUS16 IUNC'gNBJ4 .AE ALARA CCNTM PA L IJO ZT:,NE?SRICR COIDUR I ANERVISOfiv OA NEMINCtiATOP OPQR =lt t'A'„ OM CONTACT WNG 111.1.1K.M 104 AT US AND CONDUIT CONNECTORS 1)90712SVOC. 115 131 411 VOLTAGE AGE SOUu LAIR 1.1lTS RCE _ NEAMF 1::kzm R.tmm�zI SwWLN ka pN pnnlrol NOTE:The above diagram shows a connection between the common terminal(yellow—Si and yellow-with-orange stripe—52)and the normally closed terminal(blue—S1 and blue-with-orange stripe—S2). In this example,the indicator light and alarm will stay on until the valve is fully open. When the valve is fully open,the indicator light and alarm will go out.Cap off any unused wires (e.g.brown with orange stripe). Only Sl (two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). www.victaulic.com .ctaul c VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.®2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.81_6 10.81 FireLock® Butterfly Valve SERIES 705 WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications,designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve.Verify you have the latest revision by visiting our website at www.victaulic.com.Further reference can be found in the 1-100 Victaulic Field Installation Handbook. For complete contact information,visit www.victaulic.com 10.81 5662 REV E UPDATED 04/2013 ‘At2Ul11C VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY.40 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED. 10.81 • IPS CARBON STEEL PIPE- FIRE PROTECTION VALVES 1 0.75 FireLock® Butterfly Valve °®° ® VdS - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR t (r The Series 707C butterfly valve features a weatherproof actuator housing approved for ' indoor or outdoor use.It has been developed for fire pump metering test lines,per NFPA 20 and rooftop test units,as well as pressure reducing valve by-pass lines per NFPA 14.The Series 707C has a ductile iron body and disc with EPDM disc coating. Designed for fire protection services only.Contact Victaulic for details of agency approvals. The Series 707C Butterfly Valve is designed to be SUPERVISED CLOSED. Under normal operating conditions,this valve will be CLOSED,and the internal limit switches will supervise the valve only in the CLOSED position.The valve will be in the open position only during system testing and maintenance.This supervised closed Series 707C Butterfly Valve should NOT be installed where fluid flow is required as part of normal system operation. • APPROVALS AND LISTINGS A pprovaiiL0ti 18 Service Pressure Serves 7070 Butterlly Valet cULus 1 FM VdS 2750mm ( upto30opsi/2068kPa mil n/a 3 up to 300psi/2068kPa 2 1/2Y65mrvi up to 300psi/2068kPa up to 300psi/2068kPa ( n/a 761mm up to 300psi/2068kPa up to 300psi/7068kPa up to 300psi/2068kPa 47100mm + up to 300ps1i/2068<Pa up to 300ps/2068kPa up to 30opsi/2068kPa to 3780mm u to 300 si/2068kPa up to 300 sV2068kPZ up t n/a 300ps/2068kPe 133mm up to 30Ops/20631Pd n/a n/a 57125mm up to 300o,/20681Pa up to 300psi/2068kPa up to 300ps'/20E31Pa 139.7mm !. up to 3040i/20681<Pa up to 30Ops1/2068kP4 n/a 67150mm. '. up:o 3C0psi/2068kPa up to 300p60068kna up to 3COpsi/2068k'a 159mm up to 3COpsi/2068kPa n/a r/a 1651mm up to 300psi/206810a up to 300psi/2068kPa n/a 07200mm u.to 300.51/2058k'2 o.to 300.s1/2O68kPa u.to 300 si/2068kPa JOB/OWNER CONTRACTOR ENGINEER System No. Submitted By Spec Sect Para Location Date Approved Date www.victaulic.com xictaulia VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02013 VICTAULIC COMPANY.ALL RIGHTS RESERVED REV F 10.751 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 10.75 FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR MATERIAL SPECIFICATIONS Body:Ductile iron conforming to ASTM A-536,grade 65-45-12 End Face, 2—6750—150mm:Ductile iron conforming to ASTM A-536,grade 65-45-12 Seal Retainer,8"/200mm:Ductile iron conforming to ASTM A-536,grade 65-45-12 Coating:Black alkyd enamel Disc:Ductile iron conforming to ASTM A-536,grade 65-45-12,with electroless nickel coating con- forming to ASTM B-733 Seat: • Grade"E"EPDM Stems:416 stainless steel conforming to ASTM A-582 Stem Seal Cartridge:C36000 brass Bearings:Stainless Steel with TFE lining Stem Seals:EPDM Stem Retaining Ring:Carbon steel Actuator: • 2-8'/50-200mm: Brass or bronze traveling nut on a steel lead screw,in a ductile iron housing www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED r Cta u ll i C. 10.75_2 i. ' • IPS CARBON STEEL PIPE-FIRE PROTECTION VALVES 10.75 FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR DIMENSIONS- Sbr Dimension,. L,ehesirn Jlurreters �fl�1�0 I Outside End to Size 'i Diameter End j A B C 0 E F 1 G DIAH J 2' 2.375 . 4.25 2.28 6.41 4.00 4.22 450 2.12 (1±.41- 603 trim 60.3 1080 579 1618 1016 1072 1143 53.8 H1: 2'h 7.875 377 778 754 400 4.22 450 177 73 mm 73.0 958 579 1915 . 101.6 1072 1143 45.0 1 i 3.000 977 579 754 n 4.00 4.22 440 450 761 mm ■ 76.1 95.8 579 191 5 101.6 10 114 i 450 F V 3' 3.500 377 2.53 779 4.50 4.22 4.50 1.77 VIII 0 88.9 mm 88.9 95.8 64.3 19/.9 - 114.3 1072 114.3 45.0 4.250 463 288 881 _ 550 422 450 2.20 108 mm 108.0 1176 73.2 223.8 - 1397 1072 114.3 ! 55.9 4' 4.500 4.63 2.88 8.81 550 4.22 4.50 2.20 l` 1143 mm 114.3 1176 732 2238 1397 1077 1143 55.9... 0H 5 250 5.88 3 35 10 88 6 56 619 6 30 2.58 - I0 133mm 133.0 149.4 831 .176.4 1656 1572 1600 65.5.. C III _ 5.500 : 5 88 3.35 10.88 656 619 630 - 258 139.7 mm 139.7 1494 891 2764 - 1656 1572 1600 65.6 ' 5" 5.563 588 3.35 1088 656 619 630 2.58 1413 mm 141.3 1494 851 2764 1666 15/2 1600 65.5 L iiiii I 1,,, 6.250 5.88 384 11 38 0.41 752 6.19 630 258 B 159 mm 159.0 149.4 975 2891 . 10.4 191.0 1572 1600 65.5 I--D 6.500 588 3.84 1138 041 752 6.19 630 2.58 m J d165.1 m 165.1 149.4 975 2891 104 1910 1572 1600 655 E A ._... __... 6.625 588 3.84 1138 0.41 752 619 630 1.90 168.3 1494 975 2891 10 191.0 157.2 1600 48.3... 8' 8.625 533 5.07 13.53 0.80 1.47 10.00 6.19 810 2.33 2191 mrn 219.1 '.. 135.4 128.8 3436 203 '.. 373 2540 1572 205.7 59.2 • www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK CF V1CTAULIC COMPANY C 2013 VICTAULIC COMPANY ALL RIGHTS RESERVED •CtaulIe REV F 10.75,_3 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 1 0.75 • FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR ■ PERFORMANCE The chart expresses the frictional resistance of Victaulic Series 707C Supervised CLOSED Butterfly Valve in equivalent feet/meters of straight pipe. Size Size Actual Actual Nominal Outside Nominal Outside Size Diameter Equiv. Size Diameter Egeiv. Inches Inches FeeUm Inches Inches FeeItm mm mm of Pipe mm rem � of Pipe 2 2.375 . 6 6 6.625 14 50 60.3 1.8 150 168.3 4.2 2V. 2.875 6 159 mm 159 mm 14 65 73.0 1.8 4.3 3.000 6 1651 men 6500 14 76.1 18 165.1 42 3 3.500 7 8 8.625 16 80 88.9 2.1 200 219.1 4.9 4 4.500 8 100 114.3 2.4 108 mm 108 mm 8 2.4 5 5.563 ', 12 125 141.3 3.7 133 mm 133 mm i 12 3.7 139.7 mm 5.500 12 139.7 3.7 www.victaulic.com jctsa ilid VICTAULIC IS A REGISTERED TRADEMARK OF VICTAUUC COMPANY.®2013 VICTAULIC COMPANY ALL RIGHTS RESERVED 10.75_4 REV_F IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 10.75 FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR PERFORMANCE C5 values for flow of water at+60°F/+16°C with a fully open valve are shown in the table below,For additional details,contact Victaulic. Formulas for Ct,Values: AP =Q' Where: C'' Q=Flow(GPM) AP=Pressure Drop(psi) Q= C"x 4P C, Flow Coefficient S„e sae e; �.: e_ Actual Actual Actual Nominal Outside Nominal Outside Norn'.nal Outside Size Diameter Size Diameter Size Diameter Inches Inches Inches Inches Inches Inches mm nun (Full Open) mm mm (Full Open) rein rem I (Full Open) EU2'375 170 5 5 563 1200 8.,. 8 625 3400 60.3 125 141 3 200 219.1 21/2 2,875 260 133mr1 133 rem 1200 65 730 761 mm 3.000 61 260 139.7 men 139.07 1230 3 3 500 6 6 625 80 88.9 440 _ 150 168.3 1800 4 4.500 820 159mm 159 mm 1 1800 100 114.3 108 mm 108 mm m i 820 165 1 m 6 500 1800 165.1 Formulas for Kv Values: OP = Q' Where: K Q=Flow Q = K x ,A73 AP=Pressure(bar) Ic=Flow Factor Slate K1 Size Actual l Actual I i Actual Nominal Outside Nominal Outside Nominal ' Outside Size Diameter i Size Diameter Size Diameter Inches Inches Inches Inches Inches Inches mm (Full Open) mm mm (Full Open) mm nen Well Open) 2.375 5 5.563 8 8.625 60.4 117 125 141.3 1040 200 219.1 ''.. 2940 716 7.875 225 133 mm 133 mm 1040 6s 73.0 76.1 mm 3.000 225 159.7 mm 5.500 1040 6.1 139.7 3 3 500 6 6.625 80 88.9 380 150 168.3 1560 4 4 500 710 159 rem I 159 rrun 1560 100 114.3 108 mm 108 mm 710 165.1 mm 6.500 1560 1651 www.victaulic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02013 VICTAULIC COMPANY.ALL RIGHTS RESERVED LCta uluC REV F 10.75...,5 IPS CARBON STEEL PIPE—FIRE PROTECTION VALVES 1 O,75 • FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR SWITCH AND WIRING 1.The supervisory switch contains two,single pole,double throw,pre-wired switches. 2.Switches are rated: 10 amps @ 125 or 250 VAC/60 Hz 0.50 amps l 125 VDC 0.25 amps 411 250 VDC 3.Switches supervise the valve in the"CLOSED"position. 4.One switch has two#18 insulated wires per terminal,which permit complete supervision of leads (refer to diagrams and notes below).The second switch has one#18 insulated wire per termi- nal.This double circuit provides flexibility to operate two electrical devices at separate locations, such as an indicating light and an audible alarm,in the area that the valve is installed. 5.A#14 insulated ground lead(green)is provided. Switch#1=Si For connection to the supervisory circuit of a UL Listed alarm control panel Switch#2=S2 Auxiliary switch that may be connected to auxiliary devices,per the authority having jurisdiction Normally Closed:(2)Blue S1 Common:(2)Yellow Normally Closed:Blue with Orange Stripe S2 Normally Open:Brown with Orange Stripe Common:Yellow with Orange Stripe IN.Lnom 14. RRIAUI CONTROL N [L CONDUIT ,I m i0f4>CFUNE PESISfpR SUPEWSOW ON NE�'RINa'CALCP 1 CIRCUIT ►�t� ii ' lid l ':. ccnrAn.ennP� ® r CONNECTORS IOP Lsrp c, zsaASC. WRtIS OSAAi I]54K oss nxauc VOCAGESCOPCE 41 5u4N 1:lletlsp"E.mOyl 1111,[h l:l MG pnle,minal NOTE:The above diagram shows a connection between the common terminal(yellow—S1 and yellow-with-orange stripe—S2)and the normally closed terminal(blue—S1 and blue-with-orange stripe—S2).In this example,the indicator light and alarm will stay on until the valve is fully CLOSED. When the valve is fully CLOSED,the indicator light and alarm will go out.Cap off any unused wires (e.g.brown with orange stripe). Only S1 (two leads per terminal)may be connected to the fire alarm control panel. The connection of the alarm switch wiring shall be in accordance with NFPA 72 and the auxiliary switch per NFPA 70(NEC). www.victautic.com VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.02013 VICTAULIC COMPANY.ALL RIGHTS RESERVED If^i�.'auIl�i 10.75_6 REV_F ...Yd.1GSaMvue-.SbakaawOtikN'.Li£sP+M.i^ ••••5LA'ht- FireLock® Butterfly Valve - Supervised CLOSED SERIES 707C WITH WEATHERPROOF ACTUATOR WARRANTY Refer to the Warranty section of the current Price List or contact Victaulic for details. NOTE This product shall be manufactured by Victaulic or to Victaulic specifications.All products to be installed in accordance with current Victaulic installation/assembly instructions.Victaulic reserves the right to change product specifications.designs and standard equipment without notice and without incurring obligations. INSTALLATION Reference should always be made to the installation sheet included with the valve.Verify you have the latest revision by visiting our website at www.victaulic.com.Further reference can be found in the 1-100 Victaulic Field Installation Handbook. .............._._.... . For complete contact information,visit www.victaulic.com 10.75 5198 REV F UPDATED 03/2013 ictauIIC VICTAULIC IS A REGISTERED TRADEMARK OF VICTAULIC COMPANY.0 2013 VICTAULIC COMPANY.ALL RIGHTS RESERVED 10.75 I i 1' I 1 r I I k z f f i F ¢E i 1 i� 1 1 't I I' Fire Lock® Check Valves ✓ ctauL-c Series 717 & 717H 10.08 Grooved ends allow fast, easy installation with just — -p two Victaulic couplings or the valve may be mounted to flanged (ANSI CL.150)equipment using either to Victaulic Style 741 Vic-Flangee or Style 744 FireLock flange adapters on either end. Series 717 Series 717 (21/2-3165-80 mm) (4-121100-300 mm) Series 717H High Pressure Check Valve (2-3/50-80 mm) Approvals/Listings: c0 us E vds [PCB MED See Victaulic Publication 10.01 for more details. The FireLock Series 717 Check Valve and Series 717H High Pressure Check Valves are CAD designed for hydrodynamic efficiency and available in 2750 mm—3"/80 mm (Series 717H)and 2 W/65 mm— 127300 mm (Series 717) sizes. Series 717H valves are cULus Listed and FM Approved for service up to 365 psi/2517 kPa. See chart below for approved services for the Series 717 valves. In both valve designs,the single-disc mechanism incorporates a spring-assisted feature for nonslamming operation. This spring-assisted, single-disc design achieves a leak-free seal with as little as 5ft/1.5m of head. Series 717 and 717H FireLock Check Valves can be installed either vertically(flow upwards only)or horizontally. A cast flow arrow indicator is provided to assist with proper valve orientation. Both valves include upstream and downstream pressure taps. Each valve is factory-tested to the rated working pressure. For systems requiring a Riser Check option, refer to publication 10.09. Job/Owner Engineer System No. Spec Section Location Paragraph Contractor Approved Submitted By Date Date Check Valve I FireLock®I Series 717&717H I Publication 10.08 victaulic.com 1 ✓ctaultc Check Valve I Firelock®I Series 717&717H I Publication 10.08 Material Specifications: Spring: All sizes Type 302/403 Stainless Steel • Housing: Shaft Plug: Ductile iron conforming to ASTM A-536, grade • Series 717H (2—3"/50—80 mm): Type 416 Stainless 65-45-12. Ductile iron conforming to ASTM A-395, Steel grade 65-45-15, is available upon special request. • Series 717 (2 ' — 12"/65—300 mm): Carbon steel Body Coating: zinc plated Series 717H Body: Black Paint Pipe Plug: Series 717H Endface: Electroless Nickel • Series 717H (2—3750—80 mm): carbon steel zinc Series 717 (2 t —3"): PPS Coating plated Series 717 (4— 12"): Black Paint • Series 717 (4— 127100—300 mm): Carbon steel zinc Body Seat: plated Series 717H—Nitrile 0-ring installed into an electroless nickel plated endface Series 717(2 'h-3"): PPS Coated ductile iron Series 717 (4— 12'): Electroless Nickel plated Disc Seal or Coating: (specify choice') ❑ Grade "T" nitrile (Series 717H Only) Nitrile(Orange color code).Temperature range—20°F to +180°F/-29°C to+82°C. Recommended for petroleum products,air with oil vapors,vegetable and mineral oils within the specified temperature range;except hot,dry air over+140°F/+60°C and water over+150°F/+66°C. NOT RECOMMENDED FOR HOT WATER SERVICES. ❑ Grade "E" EPDM (Series 717 Only) EPDM(green color code).Temperature range-30°F to +230°F/-34°C to+110°C. Recommended for cold and hot water service within the specified temperature range plus a variety of dilute acids,oil-free air and many chemical services. NOT RECOMMENDED FOR PETROLUEM SERVICES. ' Services listed are General Service Recommendations only.It should be noted that there are services for which these gaskets are not recommended.Reference should always be made to the latest Victaulic Gasket Selection Guide for specific gasket service recommendations and for a listing of services which are not recommended. Discs: • Series 717H (2—3750—80 mm): CF8M Cast Stainless Steel • Series 717 (2 1—3"): Aluminum bronze with elastomer seal • Series 717 (4— 127100—300 mm): Elastomer encapsulated disc with electroless nickel plated seat Shaft: • Series 717H (2—3750-80 mm): Brass • Series 717 (2 ' —3"): Type 416 Stainless Steel • Series 717 (4— 127100—300 mm)Type 316 Stainless Steel victaulic.com 2 ✓ctauliic Check Valve I Firelock!I Series 717&7171-11 Publication 10.08 • ApprovaUListing: Approval/Listing Service Pressures Series 717H Size cULus FM LPCB Vds 2'/50 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 21/2"/65mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 ps1/2517 kPa up to 365 psi/2517 kPa 76.1mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 3"/80 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa 4"/100 mm n/a n/a n/a n/a 5"/125mm n/a n/a n/a n/a 139.7mm n/a n/a n/a n/a 6"/150mm n/a n/a n/a n/a 165.1 mm n/a n/a n/a n/a 8"/200mm n/a n/a n/a n/a 10"/250 mm n/a n/a n/a n/a 12"/300mm n/a n/a n/a n/a Approval/Listing Service Pressures Series 717 Size cULUS FM LPCB Vds 2"/50 mm n/a n/a n/a n/a 2W/65 mm up to 250 psi/1725 kPa n/a up to 365 psi/2517 kPa n/a 76.1 mm up to 250 psi/1725 kPa n/a up to 365 ps1/2517kPa up to 16bar/232 psi 3"/80 mm up to 250 psi/1725 kPa n/a up to 365 psV2517 kPa up to 16bar/232 psi 4"/100 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 5'/125 mm up to 365psi/2517kPa up to 365 psi/2517kPa up to 365 ps1/2517kPa n/a 139.7mm up to 365 psi/2517 kPa up to 365 psV2517 kPa up to 365 psi/2517kPa up to 16bar/232 psi 67150 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 16bar/232 psi 165.1 mm up to 365 psi/2517 kPa up to 365 psi/2517 kPa up to 365 psl/2517 kPa n/a 8'/200 mm up to 365 ps12517 kPa up to 365 psi/2517 kPa up to 348 psi/2400 kPa up to 16bar/232 psi 10"/250mm up to 250 psi/1725 kPa up to 250psi/1725kPa up to 1725 kPa/250 psi n/a 12/300 mm up to 250 ps1/1725 kPa up to 250 psi/1725 kPa up to 1725kPa250psi n/a victaulic.com 3 ✓Ctaulio" Check Valve I Firelock= I Series 717&717H I Publication 10.08 Dimensions- Series 717: A -+ R � � is _A 7 Will i N"Ii'i \�/� IIIIa �II w i I�I� .._l DE ..� E A 8 s Ila-K"� f) k K-.! O O 8-s - �IJk- O -g -rJir II 11 : 01 i O 'h"NPT Upstream Drain 0 V?NPT Upstream Drain m 1"NPT Downstream Drain ®h"NPT Downstream Drain 1 ® 2"NPT(Drain Optional) Typical 2 1/2-3"/65-80mm Typical 4-8"/100-200 mm Typical 10-12"/250-300 mm Actual Dimensions Nominal Outside E to E Weight Size Diameter A B C D E J K P R inches Inches inches inches Inches inches inches inches inches inches inches mm mm mm mm mm mm mm mm mm mm mm 21/2 2.875 3.88 4.26 3.57 - - - - - - 65 73.0 99 108 91 76.1 mm 3.000 3.88 4.26 3.57 - - - - - - 76.1 99 108 91 3 3.500 4.25 5.06 4.17 _ _ _ _ - - 80 88.9 108 129 106 2.0 4 4.500 9.63 6.00 3.88 2.75 3.50 2.00 4.50 3.50 3.35 20.0 100 114.3 245 152 99 70 89 51 114 89 85 5 5.563 10.50 6.80 4.50 _ 4.17 2.15 5.88 4.08 3.98 27.0 125 141.3 267 173 114 106 55 149 104 101 12.3 139.7 mm 5.500 10.50 6.80 4.50 - 4.17 2.15 5.88 4.08 3.98 27.0 139.7 267 173 114 106 55 149 104 101 12.3 6 6.625 11.50 8.00 5.00 _ 4.50 2.38 6.67 4.73 3.89 38.0 150 168.3 292 203 127 114 61 169 120 99 17.2 165.1 mm 6.500 11.50 8.00 5.00 - 4.50 2.38 6.67 4.73 3.89 38.0 165.1 292 203 127 114 61 169 120 99 17.2 8 8.625 14.00 9.88 6.06 5.05 5.65 2.15 8.85 5.65 5.75 64.0 200 219.1 356 251 154 128 144 55 225 144 146 29.0 10 10.750 17.00 12.00 7.09 5.96 6.69 2.15 10.92 6.73 _ 100.0 250 273.0 432 305 180 151 170 55 277 171 45.4 12 12.750 1950 1400 8.06 6.91 7.64 251 12.81 7.73 - 140.0 300 323.9 495 356 205 176 194 64 925 196 63.5 Dimensions-Series 717H: A < s- rkilii ill"' D E R 1 Typical 2"/50 mm-3"180 mm Dimensions Approx. Nominal E to E Weight Size A B C D E .1 K P R Each inches Inches inches inches inches inches Inches inches inches inches lbs. mm mm mm _ mm mm mm mm mm mm mm kg 2 8.66 6.46 3.23 1.48 3.02 2.80 _ - 4.25 10.7 50 219.8 164.1 82.1 37.5 76.7 71.0 108.0 4.9 21 9.37 6.94 3.31 1.66 3.40 3.38 - _ 4.38 13.8 65 238.0 176.3 84.1 42.2 86.4 85.9 111.3 6.3 9.37 6.94 3.31 1.66 3.40 3.38 - _ 4.38 13.8 76.1 mm 238.0 176.3 84.1 42.2 86.4 85.9 111.3 63 3 9.62 7.44 3.53 1.91 3.65 3.38 _ - 4.63 20.0 80 2443 189.0 89.7 483 92.7 85.9 117.6 9.1 victaulic.com 4 ✓ctaulrc' Check Valve I Firelock®I Series 717&717H I Publication 10.08 • Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. 5717H/717HR 10 I 9 1 1 b v N a` 0.1 10 100 1 c 1 Flaw—GPM S717H/717HR 10030 F F F cer E F '1 FF ZS o° 0e•-`..'5'' ,b F Fc FF 8 10.00 ,�o ^' o- FF v °. ,h° �„'oo w b v ` 1.00 100 1.00 10000 10000u Flaw Rate— Litres/min. victaulic.com 5 ✓ctaul.0 Check Valve I Firelock®I Series 717&717H I Publication 10.08 Flow Characteristics The charts below express the flow of water at 60°F/16°C through valve. $717/717R -; 10 °::'w t ' k i' '�`1 r'.1.I• �� 'i`" �1 f k-. rl F oFF � ^� F QpFc r 1 n F <� FF F F M� 1� 0 , ai 0.1 10 CO' 1000 1000e 100000 Flow—GPM S717/717R 10 eF FF ^+- e= FF O S 43 F F 0.1 10 100 1G00 10000 100000 Flow—GPM • Installation Note Reference should always be made to the 1-100Victaulic Field Installation Handbook for This product shall be manufactured by Victaulic or to Vldaulic specifications.All products the product you are installing.Handbooks are included with each shipment of Victaulic to be installed in accordance with current Victaulic installation/assembly instructions. products for complete installation and assembly data,and are available in PDF format Victaulic reserves the right to change product specifications,designs and standard on our website at www.victaulic.com. equipment without notice and without incurring obligations. Warranty Trademarks Refer to the Warranty section of the current Price List or contact Victaulic for details. Victaulic and fireLock are registered trademarks of Vlctaulic Company. 10.08 1479 Rev.R Updated 05/2014 C 2014 Victaulic Company.All rights reserved. �Ct:aulic' victaulic.com 6 Model 1011A TESTAN DRAIN® Sectional Floor Control Test and Drain Valve for Systems Requiring Pressure Relief Valve 1101.c �Lus APP 3,14" 1° 11�4" 1"/21 2" , .' ft` _ TEST s;t.OIRW /r'11 u f r+�; t. T St7E .aft 0090E1.tOir. •The AGF Manufacturing Inc. Model 1011A TESTANDRAIN®matches all the features and benefits of our Model 1000 by providing both the test function and the express drain function in a multistory installation for a wet fire sprinkler system,with the added feature of an integral Model 7000 Pressure Relief Valve with drainage piping. •The Model 1011A complies with the requirements of NFPA-13 that stipulate a pressure relief valve be installed on all gridded systems and downstream of all pressure reducing valves(see reverse). •The Model 1011A TESTANDRAIN®is a compact single handle ball valve which includes a tamper resistant test orifice and integral tamper resistant sight glasses,and is 300 PSI rated. •Available in a full range of sizes from 34" to 2" NPT and BSPT, with all specifiable orifice sizes 3/4" (2.8K), 7/16'1 (4.2K), 1/2" (5.6K), 17/a2" (8.0K),5/a" (11.2K, ELO), 3 4" (14.0K, ESFR), and K25 as required by NFPA 13,2007 Edi- tion(see reverse). •The included UUFM Model 7000 Pressure Relief Valve features a flushing handle and is factory rated for 175 PSI. Other pressure settings are available and may be substituted. • Designed to relieve excess system pressure caused by surges or temperature changes as well as solve the dif- ficult problem of providing the relief valve with a convenient drainage-piping outlet. • Shipped with relief valve and bypass drain ports plugged to expedite pressure testing the system. •A locking kit is available and can be ordered with the valve to provide vandal resistance or prevent uninten- tional alarm activation. • Repair kits including(1)adapter gasket, (1) ball, (2)valve seats, (1)stem packing, and(1)stem washer are avail- able for all TESTANDRAIN®valves.Valve and orifice size must be specified when ordering. NOTE: It is important to note that the pressure rating of the relief valve indicates an operating range of pressure for both opening and closing of the valve.Standard relief valves are required to OPEN in a range of pressure between 90%and 105%of their rating.The valves are required to CLOSE at a pressure above 80%of that rating.The relief valve should be installed where it is easily accessible for main- tenance.Care should be taken that the relief valve CANNOT be isolated from the system when the system is operational.A relief valve should NEVER have a shutoff valve or a plug downstream of its outlet. Reliability, Versatility, Code Compatibility TESTANDRAIN is a registered trademark of AGF Manufacturing Inc. CS1011A 10/09 AP Model 1011A °S T ESTAN D RAI N. ® Model 1011A 300 PSI Bronze Ball Valve, Model 7000 Pressure Relief Valve ARMED Factory Rated at 175 PSI with other settings available DIMENSIONS MODEL 1011A - FRONT VIEW Orifice Size Available:3/8",7/16", 1/2",11/22", ELO(5/a")*, ESFR(3/4")*,&K25"* A 1 INLEE---1 SIZE A B C D E F G H E 7�6" 11/2" 23/16" 3W' 33/4" 113A6" 49/16" 60" TO F 0 r �' �� (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) D N l ow 7�s" 11/2" 23/i& 35/6" 33/4" 114/6" 49h6" 63/9" - 1" (191 mm) (37.5 mm) (57 mm) (93 mm) (86 mm) (46 mm) (117 mm) (162.5 mm) c I`.7.t..1-Wi7.�_'. N. 11/4' 715/16" 111A6" 29A& 41/4" 3W 11 6" 51/16" 51/2" (201 mm) (43 mm) (65 mm) (108 mm) (91 mm) (51 mm) (141 mm) (192 mm) 1yz" 813/16" 113A6" 31/4" 51/16" 33/4" 2W 81/4" 100" MODEL 1011A - PLAN VIEW (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) 2," 815As" 113Ae. 31/4" 51A6' 30" 2W" 81/4" 107/4" II A .-I (227 mm) (45 mm) (81.5 mm) (127 mm) (99 mm) (67 mm) (207 mm) (274 mm) *Available on 11/4"to 2"size units only Available on 1 1"and 2"size units only 1 L .. 1 TO B ��' y y 1—D mom THE MODEL 101 1A PROVIDES ALL OF THE FOLLOWING... ,�/ JIM' 1 � 'Cli I From the 2007 Edition of NFPA 13 O Chapter 8.16.2.4.1* Provisions shall be made to properly drain all parts of the system. eJ Chapter 8.16.2.4.2 Drain connections,interior sectional or floor control valve(s)— &8.16.2.4.3 shall be provided with a drain connection having a minimum size as shown in Table 8.16.2.4.2. MATERIALS Chapter 8.16.2.4.4 Drains shall discharge outside or to a drain capable of handling Handle:Steel the flow of the drain. Stem:Rod Brass Chapter A.8.17.4.2 (Wet Pipe System)test connection is permitted to terminate into Ball:C.P.Brass a drain capable of accepting full flow... using an approved sight Body:Bronze test connection containing a smooth bore corrosion-resistant Valve Seat: Impregnated Teflon® orifice giving a flow equivalent to one sprinkler... Indicator Plate:Steel Chapter 8.17.4.2.2 The test connection valve shall be readily accessible. Relief Valve: Bronze Chapter 8.17.4.2.4 shall be permitted to be installed in any location... downstream Bypass Fittings:Brass of the waterflow alarm. Bypass Tubing:Nylobraid Chapter 8.17.4.3.1 (Dry Pipe System)a trip test connection not less than 1" in diameter,terminating in a smooth bore corrosion-resistant orifice, APPROVALS to provide a flow equivalent to one sprinkler... UL and ULC Listed:(EX4019 Chapter 8.17.4.3.2 The trip test connection...with a shutoff valve and plug not less &EX4533) than 1",at least one of which shall be brass. FM Approved Chapter 7.1.2 -a gridded wet pipe system shall be provided with a relief valve NYC-BSA No.720-87-SM set to operate at 175 PSI or 10 PSI in excess of the maximum system pressure,whichever is greater. Chapter 8.16.1.2.3* A relief valve of not less than 1/z° in size shall be provided on the discharge side of the pressure-reducing valve set to operate at a pressure not exceeding 175 PSI. Chapter A.8.16.1.2.3 -consideration should be given to piping the discharge from the (pressure relief)valve MADE IN U.S A. USA Patent # 4741361 and Other Patents Pending G AGF Manufacturing Inc. Job Name: 100 Quaker Lane,Malvern,PA 19355 Phone:610-240-4900 Architect: FFax:610-240-4906 Engineer: www.testandrain.com Contractor: • 'Apta'Valves 64 SERIES w mopolluvalvea.com Full-Port Brass Ball Valve Job Name: Contractor: Job Location: P.O. Number: Engineer: Representative: Tag: Wholesale Distributor: DESCRIPTION The Apollo®International 64 Series is an economy full port forged brass ball valve ideal for a wide range of plumbing and heating applications. FEATURES • 100% Factory Tested to MSS SP-110 • Meets ANSI/NSF 61-2004 t • Blow-out Proof Stem Design + ; • Adjustable Stem Packing • Secondary 0-ring Stem Seal „ „'Fa � • Directive 2002/95/CE(RoHS)Compliant � t` PERFORMANCE RATING DIMENSIONS • Valve Design Rating:600 CWP, 150 SWP Part No.1 Size I A I B I C I D !Cy 1wt.(Ibs.) • Max Temperature:366°F NPT 64-101 1/4" 0.39 2.02 1.75 3.85 6 0.33 MATERIALS 64-102 3/8" 0.39 2.02 1.75 3.85 7 0.30 Part Name Material 64-103 1/2" 0.59 2.44 1.88 3.85 19 0.51 64-104 3/4" 0.78 2.71 2.28 4.80 34 0.80 Body Forged Brass(Cu>57%) 64-105 1" 0.98 3.07 _2.44 4.80 50 1.25 Retainer Forged Brass(Cu>57%) 64-106 1 1/4" 1.25 3.42 3.07 6.02 104 2.26 64-107 1 1/2" 1.57 3.89 3.34 6.02 268 3.39 Ball Brass,Cr plated 64-108 2" 1.96 4.33 3.79 6.37 309 4.25 Stem Brass,Cr plated 64-109 2 1/2" 2.56 5.59 5.02 8.07 629 8.60 64-100 3" 3.15 6.45 5.45 8.07 1018 13.35 Seat Ring PTFE 64-10A 4" 3.94 7.60 6.34 10.23 1622 22.05 Stem Seal NBR 75 Shore A SOLDER 64-203 1/2" 0.59 2.53 1.88 3.85 19 0.51 Stem Packing PTFE _ 64-204 3/4" 0.78 2.99 2.28 4.80 34 0.78 Packing Nut Plated Steel 64-205 1" 0.98 3.58 2.44 4.80 50 1.14 Packing Gland Brass 64-206 1 1/4" 1.25 4.09 3.07 6.02 104 2.07 64-207 1 1/2" 1.57 4.56 3.34 6.02 268 3.42 Handle Zinc Plated Steel 64-208 2" 1.96 5.43 3.79 6.37 309 4.49 Handle Cover PVC 64-209 2 1/2' 2.56 6.93 5.02 8.07 629 1 0.00 64-200 3" 3.15 8.09 5.45 8.07 1018 15.00 64-20A 4" 4.13 10.25 6.34 10.23 1622 25.00 APPROVALS CSA: %"-4"NPT pe ANSI Z21.15/CGA 9.1 (1/2 psi) ''Y4"-4"NPT per ASME B16.44(5 psi) W-2" NPT per ASME B16.33(125 psi) F 2 W-4" NPT per ASME B16.38(125 psi) -, ILL: W 1"UL 125, "Guide YSDT" W-1"UL 842, "Guides YRPY,JRBX,MHKZ W-2"UL Subiect 258,"Guide VQGU" FM: '1h"-2"per FM1140 rs •_ NSF: ANSI/NSF 61-2004, "Drinking Water System F Components-Health Effects." K I i I _i OPTIONAL KITS ( tee, I arT rad7n r"n;l Valus Size Locking Handle 2"Stem Extension Balancing Stop . v 1,---/-.� .,- -.," 1/4", 3/8', 1/2" 78185902 78150101 78150601 -.®_... K..__..____.-.. 78166002 78150201 78150701 1-1/4°, 1-1/2° 78166102 78150301 78150801 2' 78166202 78150401 78150901 2-1/2",3° N/A 78150501 N/A 4' - N/A •Note: Locking handle cannot be used with 2"stem extension Conbraco Industries,Inc.701 Matthews Mint Hill Rd.Matthews NC 28106 USA;www.aoollovalves.com This specification is provided for reference only. Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. SS 1077.doc©6/09 Page 1 of 1 Model DCDA4SG r *APO. DValves """"'""a*" w w ppelrevpN es.eem DOUBLE CHECK DETECTOR ASSEMBLY Job Name: Contractor: Job Location: P.O. Number: Engineer: Representative: Tag: Wholesale Distributor: DESCRIPTION The Apollo® Model DCDA4SG, DCDA4SGN Double 1 Check Detector Assembly is designed to prevent contamination of the potable water supply due to back- , . siphonage or backpressure from substances that are ill 11 non-health hazards. The device consists of a mainline .' , ,t double check valve with a by-pass line. The by-pass ,, consists of a water meter and an approved Apollo® ■ : rt'=x • double-check valve with Apollo® ball valves as shut- I • offs. The by-pass serves to measure water use of up , to 3 gpm. Grooved connections on an epoxy-coated ductile iron body allow for easy connection to butterfly valves or gate valves. Note: Model DCDA4SG ORDERING INFORMATION replaces Model 4S-600 (also known as Model DCDA) in all sizes except 10". 4 SG - 6 0 X - X X X FEATURES otv u,14, I • Lightweight °, ISO 9001;200$ SIZE • Short lay length REGISTERED METER OPTION • Low pressure loss rv�r • Modular check valves SHUT-OFF VALVES • Individual access to check valves FLOW(DCDA4SGN) • Corrosion resistant epoxy-coated ductile iron body • US Patents#5,711,341 and#6,343,618 SIZE • MADE IN THE USA 0 9—2 W ❑ C—6" MATERIAL SPECIFICATIONS O 0—3" 0 E-8" Part Name Material 21 A-4" Body(mainline) Epoxy-coated(FDA)Ductile Iron METER OPTION Bypass DC Bronze C-ft'/min 0 E-gpm 0 G—no meter Covers(2%"-6") Epoxy-coated(FDA)Steel Covers(8") Epoxy-coated(FDA)Ductile SHUT-OFF VALVES(Inlet x Outlet) Iron ❑ 1 —Less Shut-off Valves(see notes) Elbows Epoxy-coated(FDA)Ductile ❑ 2—NRS Flg x NRS Flg Iron Check Valves(2 W-6") Glass-Filled Noryle 0 3-OS&Y Flg x OS&Y Flg Check Valves(8") Bronze 0 4-OS&Y Flg x Monitored (Mon.) Butterfly Vlv Gry Springs Stainless Steel 0 6-OS&Y Flg x Post Indicator Flg(Not in 2%"size) Seat Discs Chloramine-resistant EPDM 0 7-OS&Y Flg x OS&Y Gry 18f 8—OS&Y Gry x OS&Y Gry PERFORMANCE RATING ❑ 9— Mon. Butterfly Vlv Gry x Mon. Butterfly Vlv Gry Maximum Working Pressure 175 psi ❑ 10—OS&Y Flg x Post Indicator Gry(Not in 2 v="size) Temperature Range 33° F—140° F ❑ 11 -NRS Gry x NRS Gry Hydrostatic Test Pressure 350 psi ❑ 12—NRS Flg x NRS Gry APPROVALS ASSE 1048,CSA B64.5, UL*,FM*, and USC's FCCC&HR. FLOW(Optional) All approvals in horizontal and vertical flow-up 0 N—Model DCDA4SGN configurations. *UL and FM installations must include indicating-type shut-off valves. Example:4SG-60A-E7=4"size with meter in gpm and OS&Y flanged x grooved shut-off valves(shown above). Conbraco Industries,Inc.701 Matthews Mint Hill Rd.Matthews NC 28105 USA;www.aoollovalves.com;704-841-6000 This specification is provided for reference only.Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraca products previously or subsequently sold. SS1041©3/10 Page 1 of 3 A Model DCDA4SG ■ '+ ApoPQoValves Model DCDA4SGN . ., ,�USA DOUBLE CHECK DETECTOR ASSEMBLY DIMENSIONS (in.) —WEIGHTS (lbs.) Size 2 %t 3" 4'• 6" 8" A(Butterfly Valves)* 29 291/: 29% 32 43 A(Gate Valves)* 32 33 34'/ 39 50 B(Grooved-end body) 17 17 16% 18 27 . C(Butterfly Valves) 8 8'/ 9 1/ 101/4 12 C(OS&Y Open) 16% 18% 22% 30'% 37% D(Butterfly Valves) 4'/2 4'1/ 4 1/ 41/ 612 D (Gate Valves) 3 '% 3% 4 '% 5'% 6% E 9 9 9 9 10% F(Butterfly Valves) 18'% 19'% 20% 221/2 31 F(Gate Valves) 20 21 23 26 34% G 23 23% 24'% 29 40% H (Post Indicator) Not Avail. 12% 14% 19 22% Test Cocks(NPT) 1/2 /2 1/2 % % Net Wt. (Less Valves) 65 65 65 72 395 Net Wt. (w!Butterfly Valves) 92 95 109 140 526 Net Wt. (w/OS&Y Valves) 161 186 220 321 872 Notes: 1. Nominal dimensions are shown.Allowances must be made for manufacturers'tolerances. 2. Internal body connections are grooved on 21/"-8"sizes. o III .� - _ T Oiiii '� : lip lily. u. F 1 ?I � i 1 ;� F it ..®h w U'-. = T li'ig r, r��- ill' II IL t�- c t� ai .r 1 �I II® �� lil ill fr" �, H (__Li lIl ■ F i p_ e _ r s - �.y..-_ a � j (r"l.:*. MI 1.■ A O - _ epp. in ar„a A Conbraco Industries,Inc.701 Matthews Mint Hill Rd.Matthews NC 28105 USA;www.aoollovalves.com;704-841-6000 This specification is provided for reference only.Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbreco products previously or subsequently sold. SS1041©3/10 Page 2 of 3 • �� u ;y Model DCDA4SG p � Model DCDA4SGN '4aa wiedeem DOUBLE CHECK DETECTOR ASSEMBLY FLOW CURVES 2112" 3" —Horizontal/1krtcol Up----- •Flow—75 a/s - • - •Rated Now HorizonteN ticd Up-—---N-Flow—7.5 Vs• --'Rated Flan I 72 - _ i 10- o 1` 5 "-a 4 a 4 I • 0 50 100 150 200 250 300 350 400 0 100 200 300 400 500 600 Rowrate(gpm) Flowrate(gpm) 4" e,. I—HorizenteOWNcat Up-----N-Flow-7.51W - - 'Rated Flow —HorlaontaWertical Up-----N-Flow—7.5 Ns- - Rated Row I 10 c 9 J a 14 • 8 12 c r m7 ---� r 10 .l � ' a N ffi 4 n 4 0 100 200 300 400 500 600 700 BOO 0 200 400 600 800 1000 1200 1400 1600 Flowrate(gpm) Rowrate Igpmt 8" Horizontal/Vertical Up -----N-Flow .--7.5 R/s - - - .Rated Flow 'm 18 6 n 14 M O v 10 _____.-• 2 a` 0 500 1000 1500 2000 2500 Rowrate(gpm) Notes: 1. Flow curves directly reflect data collected by USC's Foundation for Cross-Connection Control and Hydraulic Research Approval curve documents. 2. Flow curves shown were recorded with butterfly shut-off valves.* 3. All data points are based on USC increasing flow data, from zero GPM to rated flow(opening curve). 4. Refer to Apollo Model DCDA4S (Formerly 4S-600 Series)for 10"valve information. * Flow curves with gate valves are slightly lower. Contact factory for more information. Conbraco Industries,Inc.701 Matthews Mint Hill Rd.Matthews NC 28105 USA;www.aoollovalves.com;704-841-6000 This specification is provided for reference only.Conbraco reserves the right to change any portion of this specification without notice and without incurring obligation to make such changes to Conbraco products previously or subsequently sold. SS1041©3/10 Page 3 of 3 . CRCDKER BUY AMERICAN ACT Fire Department Valves (Not Necessarily Domestic) Fire Hose Rack Assembly Valves FEMALE X MALE ANGLE VALVES 300LB. RATED - . e w... 'V 2 s tiee- OPTIONAL FINISHES: PB-Polished Brass { g.. RC-Rough Chrome Plated PC-Polished Chrome Plated ■ t t UIL LISTED AND FM APPROVE NY BSAIMEA APPROVED V t ipY{.jLh -7 Yu wt•ii SPECIFY THREAD Figure No. 5040-5045 Figure No. 5030-5035 STANDARD EQUIPMENT: Female STANDARD EQUIPMENT: Female NPT inlet and outlet cast brass valve NPT inlet and male hose thread with wheel handle outlet cast brass valve with wheel handle. 5030 5035 Figure No. 5040 5045 —0'—" Size 1 1/2" 21/2" A 2 9/64 3 5/32 1 • ® B 217/64 3 3/16 ��� C-Closed 6 1/2 8 3/4 ,r- C-Open 711/16 10 9/16 E D 4 1/64 5 1/8 F-h�. E 2 7/10 3 1/2 i-- F 2 3/8 3 es oo� - . L U/L Listed Yes Yes 1.-A E MUM BUY AMERICAN (Not Necessarily Domestic) These valves conform io the"Buy America Act"construction materials under Trade Agreements(July 2000, Although these valves are imported,the"Italian"country of origin meets the"Designated Country"under the World Trade Organization Government Procurement Agreement. 7 Westchester Plaza Elmsford, New York 10523 914-592-3640 I February 26,2010 NIKING® AUTOMATIC AIR TECHNICAL DATA VENT AUTOMATIC MODEL A ESFR COLD STORAGE SY' The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.co 1. DESCRIPTION The Viking Model AV-1 Automatic AirNacuum Vent was developed for application in wet pipe or preaction sprinkler systems that contain both water and antifreeze solution.This device eliminates the requirement ..r60 it o for manual venting from sprinklers or the need to add high-point bleed valves. The AV-1 is required to be installed at all high points of the s sprinkler system piping,including branch lines and main feed lines. FEATURES The stainless steel construction provides both corrosion resistance and high or low temperature operation in sprinkler system environ- ments.The low profile allows for installation at the top location of the branch pipe or supply mains of ceiling sprinkler piping.An additional ?.y"' outlet is provided for possible antifreeze sampling or back flushing to remove debris from the seat area. The AV-1 with Trim Kit includes the Model AV-1 Automatic AirNacuum Vent, Isolation Ball Valve and Strainer to protect the orifice and seat as well as allow isolation for possible replacement or maintenance of the AV-1 valve. The Model AV-1 Automatic AirNacuum Vent device is non-repairable and can only be flushed for cleaning. (If replacement of the valve is required, refer to Part Number 13494.) 2. LISTINGS AND APPROVALS: NOTE: The Viking Model AV-1 Automatic AirNacuum Vent Valve carries no listings or approvals. 3. TECHNICAL DATA Specifications Rated pressure:to 175 psi(12.1 bar)water working pressure. Viking Technical Data may be found on Factory tested:hydrostatically to 350 psi(24.1 bar). The Viking Corporation's Web site at Dimensions: Refer to Figures 1 &2. Connection Size: 'A"NPT(Inlet at bottom and 2 outlets at top location.) The Web site ma ilncl ude a more recent Discharge Venting Orifice: 1/8"(3.2 mm) edition of this Technical Data Page. Material Standards Body:Stainless Steel UNS-S30400 Float:Stainless Steel UNS-S30400 Seat: 17-4 Stainless Steel Linkage Components:Stainless Steel UNS-S30400 Ordering Information Model AV-1 Valve and Trim Kit:Part Number 13495 Model AV-1 Vent Valve Only: Part Number 13494 Available since 2005. 4. INSTALLATION 1. The AV-1 Assembly must be installed on top of the highest point of each branch line and/or supply main pipe. 2. In order to install the AV-1 assembly in the space from the ceiling to the sprinkler, the isolation ball valve and strainer must be installed in the horizontal position as illustrated in Figure 2 and the AV-1 must be installed with the (2)outlet connections at the top location.This position is critical in order to allow the float within the device to operate properly. 3. The outlet connection needs to be piped using 3/8" (9.5 mm) outside diameter plastic or copper tubing unrestricted downward and away from protected product below.This is due to possible small amounts of moisture that could spurt out during venting of the system. Copper is recommended in order to function during and after fire situations and long-lasting durability.Attach to the 'A"NPT vent connection as shown in Figure 3. 5. OPERATION The Viking AV-1 device is a float operated automatic air vent that is installed at high points of the sprinkler system where air pockets can accumulate.As the system fills,air is automatically vented through the orifice of the vent valve.When the system is full,the water Form No. F_091905 Revised page replaces page 53a-c,dated September 28,2006. (Removed FM Approval.) February 26,2010 c AUTOMATIC AIR/VACUUM C' TECHNICAL DATA VENT - MODEL AV-1 m ESFR COLD STORAGE SYSTEM co ,tg Corporation, 210 N Industrial Park Drive, Hastings MI 49058 :chnical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com the float due to buoyancy and shuts off the outlet orifice.As air throughout the system accumulates at the ig,it will be automatically expelled to provide air-free system piping. _..rice, air is allowed to enter the piping system for quick and complete drainage of the system piping.Airflow is restricted due to differential pressure across vent orifice.It is recommended to slow fill the system initially to minimize _ .,utidup of air in the system.After the system is completely filled with liquid,then increase the pressure to the desired operating static state.See Table 1 for air flow capacity at various differential pressures. Having the AV-1 installed on the end of each high-point branch line and/or main provides quicker and more complete drainage of sys- tem piping.This is because during drainage of system piping,the AV-1 will open and allow air to enter and break the vacuum inside the piping. 6. INSPECTIONS, TESTS AND MAINTENANCE 1. The top inlet connection can be used as a sampling discharge connection that can be piped to a floor level location,or attach a manual bleed valve to take sample antifreeze from desired locations. If this connection is not being used,then it must be plugged with the pipe plug furnished with product. 2. Regular inspection for leakage from the discharge outlet and plugging of the strainer is recommended. By shutting off the isola- tion valve,open strainer screen plug, drain liquid from the assembly,the float should open. Check the strainer for debris, clean, and reassemble.Open the isolation valve slowly and make sure the AV-1 vents and shuts off when filling with liquid.Opening the isolation valve slowly will prevent the alarm system from operating due to fast liquid flow past the sprinkler system alarm valve. 3. When using the outlet connection as a sample point for the antifreeze system,allow to flow long enough to obtain solution sample from the branch pipe area and not from the drop leg of the sample tube. 4. It is normal on hydronic systems to have no discharge from the auto vent valves. 5. During routine maintenance of the unit, observe air flow from the vent during recharge of the AV-1. During proper operation, air will flow from outlet followed by a small amount of liquid,then shut off. 6. If debris is collected on the seat, liquid leakage will occur.Isolate with the ball valve.Remove the AV-1 and back flush using clean water through the outlet vent connection to flush out scale and debris. Re-check operation before reinstallation. If there is still improper function, replacement of the AV-1 valve is required. 7. AVAILABILITY The Viking Model AV-1 Automatic AirNacuum Vent is available through a network of domestic and international distributors. See the Viking Corp.Web site for closest distributor or contact The Viking Corporation. 8. GUARANTEES For details of warranty,refer to Viking's current list price schedule or contact Viking directly. FebRuary 26,2010 Freezer Storage 53c NIKING® AUTOMATIC A TECHNICAL DATA VENT - MODEL DEL AV-1 V-1 ESFR COLD STORAGE SYSTEM The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email:techsvcs@vikingcorp.com Table 1 -Discharge of Air Through an Orifice at Standard Atmospheric Pressure of 14.7 psia and 70 Deg. F Pressure 5 20 40 50 60 70 80 90 100 110 125 150 175 PSI(bar) (0.34) (1.38) (2.76) (3.45) (4.14) (4.83) (5.52) (6.21) (6.90) (7.59) (8.62) (10.34) (12.07) Airflow 2.58 4.99 7.71 9.24 10.80 12.30 13.80 15.30 16.70 18.20 20.50 24.20 27.90 SCFM(Usec) (1.22) (2.36) (3.64) (4.36) (5.10) (5.81) (6.51) (7.22) (7.88) (8.59) (9.68) (11.42) (13.17) SCFM• (CFM or ACFMI X (114 7p) X 520 Where: p=gauge pressure of gas or vapor(prig) (460+1) t=temperature of gas or vapor(°F) v ) r---4-11/32 (110 r'rr) - _ 1Ip (I�Illu .` 1/2' NPT FEMALE +� t I "} I 8-3/4' (222 nn) APPROX. 11-13/32' 1/2' NPT 12' (305 rut) m (29) rim) FEMALE s 2 . ...-""-- CO N glieltui�im.� 1.. 5-3/8' co N.• IlD `O MN (137 rut)1/2' NPT 1 _ FEMALE - _ - II ft 12-5/16' (313 ml Figure 2-Model AV-1 on Branch Line Pipe Figure 1 -Model AV-1 Dimensions with Tubing on Discharge&Pipe Plug 1/2' NHI NOTE DIRECTION OF ARROW LIQUID SAMPLE DRAIN - OPTIONAL ORIFICE SIZE D ;QM - ---Oa lire.Mi.\ '\ r 7 r F.N I N / < �� - - a 19 o I r 1/2' NPT WITH c Mil< r " 3/8' VENT TUBE ( r. ' 1/2' NPT (FURNISH PI N SEPARATELY) to o ,A I/2'%CLOSE IN C z NIPPLE Ii ro ■ / Kr -i _ ■ um II a III i ®- ?N ay ♦� z N r N Figure 3 - Model AV-1 F.mn ro 13 n N -.n t. ° Valve and Trim Kit rr a rr rr -r rno v� rlo rio z Sm m �o m m °z m 0 F in 21 THIS PAGE INTENTIONALLY LEFT BLANK Form No. F_091905 Revised page replaces page 53a-c,dated September 28,2006. (Removed FM Approval.) Electrical/Fire Alarm Components _ POTTER EVSR WA VANE TYPE WATERFLOW The Symbol of Protection ALARM SWITCH WITH RETARD U CULand CSFM Listed,FM Approved,LPCBApproved,For E Marked(EN12259-5)/VdSApproved model use VSR-EU 1411 -- Service Pressure: 450 PSI(31 BAR)-UL Flow Sensitivity Range for Signal: 4-10 GPM(15-38 LPM)-UL Maximum Surge: 18 FPS(5.5 m/s) Contact Ratings: Two sets of SPDT(Form C) 10.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive 10 mAmps min.at 24 VDC Conduit Entrances: Two knockouts provided for 1/2"conduit. Individual switch compartments suitable - for dissimilar voltages. Environmental Specifications: • NEMA 4/1P54 Rated Enclosure suitable for indoor or outdoor use with factory installed gasket and die-cast housing when used with appropriate conduit fitting. • Temperature Range: 40°F-120°F,(4.5°C-49°C)-UL • Non-corrosive sleeve factory installed in saddle. Service Use: Automatic Sprinkler NFPA-13 Specifications subject to change without notice. One or two family dwelling NFPA-13D Ordering Information Residential occupancy up to four stories NFPA-13R Nominal Pipe Size Model Part Number National Fire Alarm Code NFPA-72 2" DN50 VSR-2 1144402 .., „„, ." �_ _'�•r °°y-, f .:, 2 1/2" DN65 VSR-2 1/2 1144425 'n;� 1 Vll ` RNING 3" DN80 VSR-3 1144403 • Installation must be performed by qualified personnel and in 3 1/2" VSR-3 1/2 1144435 accordance with all national and local codes and ordinances. • Shock hazard.Disconnect power source before servicing.Serious 4" DN100 VSR-4 1144404 injury or death could result. 5" VSR-5 1144405 • Risk of explosion.Not for use in hazardous locations.Serious 6" DNI50 VSR-6 1144406 injury or death could result. 8" DN200 VSR-8 1144408 Optional: Cover Tamper Switch Kit,stock no.0090148 CAUTION Replaceable Components:Retard/Switch Assembly,stock no.1029030 Waterfiow switches that are monitoring wetpipe sprinkler systems shall not be used as the sole initiating device to discharge AFFF,deluge, or chemical suppression systems. Waterflow switches used for this application may result in unintended discharges caused by surges, trapped air,or short retard times. General Information Enclosure The Model VSR is a vane type waterflow switch for use on wet sprinkler The VSR switches and retard device are enclosed in a general purpose, systems. It is UL Listed and FM Approved for use on steel pipe; die-cast housing. The cover is held in place with two tamper resistant schedules 10 through 40,sizes 2"thru 8"(50 mm thru 200 mm).LPC screws which require a special key for removal. A field installable approved sizes are 2"thru 8" (50 mm thru 200 mm). See Ordering cover tamper switch is available as an option which may be used Information chart. to indicate unauthorized removal of the cover. See bulletin number The VSR may also be used as a sectional waterflow detector on large 5401103 for installation instructions of this switch. systems.The VSR contains two single pole,double throw,snap action switches and an adjustable,instantly recycling pneumatic retard. The switches are actuated when a flow of 10 GPM(38 LPM)or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. Potter Electric Signal Company, LLC • St. Louis, MO • Phone: 866-956-1211/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MFG.#5401146-REV L PAGE l OF 4 3/09 P PQTTER VSR VANE TYPE WATERFLOW ® The Symbol of Protection ALARM SWITCH WITH RETARD Installation (see Fig. 1) These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they shall be installed on the top side of the pipe where they will be accessible. The device should not be installed within 611(15 cm)of a fitting which changes the direction of the waterflow or within 24" (60 cm)of a valve or drain. NOTE:Do not leave cover off for an extended period of time. Drain the system and drill a hole in the pipe using a hole saw in a slow speed drill(see Fig. 1). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole.Roll the vane so that it may be inserted into the hole;do not bend or crease it.Insert the vane so that the arrow on the saddle points in the direction of the waterfiow.Take care not to damage the non-corrosive bushing in the saddle.The bushing should fit inside the hole in the pipe.Install the saddle strap and tighten nuts alternately to required torque (see the chart in Fig. 1).The vane must not rub the inside of the pipe or bind in any way. a CAUTION Do not trim the paddle.Failure to follow these instructions may prevent the device from operating and will void the warranty. Fig.1 Retard Adjustment DO NOT LEAVE COVER OFF FOR AN EXTENDED PERIOD OF TIME The delay can be adjusted by rotating the retard adjustment knob from I%-.01010 II ' 0 to the max setting(60-90 seconds).The time delay should be set at �� . 11 1=. the minimum required to prevent false alarms r _, (-1 \�' I i o- ALTERNATELY . 1600 �II ,l :- ALTERNATELY CAUTION I POINTS IN DIRECTION Iri�� �, I 4110 I lole must be drilled perpendicular to the pipe and vertically centered. ,` ^ / Refer to the Compatible Pipe/Installation Requirements chart for size. /` Correct Incorrect � Y MOUNT ON PIPE SO \J \J÷0 r•opp. OF WATERFLOW f\ �/ (J /1 Ill 0: III M 1 ROLL PADDLEIN ' OPPOSITE DIRECTION ADAPTER ADAPTER DIRECTION OF OF WATERFLOW WATERFLOW \ activates �- 2Omm-2mm MAX. device in one direction only) DN50 ONLY .4..... USE(2)5180162 ADAPTERS AS SHOWN ABOVE DWG.1116-It "W491116-IF Compatible Pipe/Installation Requirements tIodel Nominal Pipe Nominal Pipe Pipe Wall Thickness Hole Size U-Bolt Nuts Size O.D. Schedule 10(UL) Schedule 40(UL) BS-1387(LPC) DN(VDS) Torque inch mm inch mm inch mm inch mm inch mm inch mm inch mm ft-lb n-m VSR-2 2 DN50 2.375 60.3 0.109 2.77 0.154 3.91 0.142 3.6 0.091 2.3 VSR-2 1/2 2.5 - 2.875 73.0 0.120 3.05 0.203 5.16 - - - - 1.25+.125/-.062 33.0±2.0 VSR-2 1/2 - DN65 3.000 76.1 - - - - 0.142 3.6 0.102 2.6 VSR-3 3 DN80 3.500 88.9 0.120 3.05 0.216 5.49 0.157 4.0 0.114 2.9 VSR-31/2 3.5 - 4.000 101.6 0.120 3.05 0.226 5.74 - - - - 20 27 VSR-4 4 DN100 4.500 114.3 0.120 3.05 0.237 6.02 0.177 4.5 0.126 32 2.00±.125 50.8±2.0 VSR-5 5 - 5.563 141.3 0.134 3.40 0.258 6.55 - - - - VSR-6 6 DN150 6.625 168.3 0.134 3.40 0.280 7.11 0.197 5.0 0.157 4.0 VSR-8 8 DN200 8.625 219.1 0.148 3.76 0.322 8.18 0.248 6.3 0.177 4.5 NOTE:For copper or plastic pipe use Model VSR-CF. PRINTED IN USA MFG.45401146-REV L PAGE 2 OF 4 3/09 P POTTER vWA VANE TYPE WATERFLOW a The Symbol of Protection ALARM SWITCH WITH RETARD Fig.2 Fig.3 Fig.4 Switch Terminal Connections Clamping To remove knockouts:Place screwdriver at Break out thin section of cover when Plate Terminal inside edge of knockouts,not in the center. wiring both switches from one conduit IP AdJP' entrance. .rri. i d4° q�Ar ° ryyD,ril,6-16 0 �1�'11 /'` ' An uninsulated section of a single conductor should not be looped i/ �} - i%� around the terminal and serve as two separate connections. The -�,I r wire must be severed,thereby providing supervision of the NOTICE "1' connection in the event that the wire become dislodged from under the terminal. Failure to sever the wire may render the device Do not drill into the base as this creates f . DWG,11,6-13 inoperable risking severe property damage and loss of life. metal shavings which can create 11111101 Do not strip wire beyond 3/8"of length or expose an uninsulated electrical hazards and damage the conductor beyond the edge of the terminal block.When using device.Drilling voids the warranty. stranded wire,capture all strands under the clamping plate. Fig.5 Typical Electrical Connections ID �If 1 Notes: ii `"`,1. The Model VSR has two switches,one can be used to operate a central III POWER SOURCE I�JSUITABLEFORBELL station,proprietary or remote signaling unit,while the other contact = I 11_ M - ""I'. li�n is used to operate a local audible or visual annunciator. �I!- Jrr„ il�gi ' .iiaa>_u._11 �q∎i.• 2. A condition of LPC Approval of this product is that the electrical ill ■• - _ Il . . . entry must be sealed to exclude moisture. �i.`+r��" WATERFLOW ZONE 3. For supervised circuits,see"Switch Terminal Connections" !r� � 'iv, ir EOLR ON FIRE PANEL drawing and warning note(Fig.4). ® �II 3 ,,± 0W 11*12 Testing The frequency of inspection and testing for the Model VSR and its associated protective monitoring system shall be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction(manufacturer recommends quarterly or more frequently). If provided,the inspector's test valve shall always be used for test purposes.If there are no provisions for testing the operation of the flow detection device on the system,application of the VSR is not recommended or advisable. A minimum flow of 10 GPM(38 LPM)is required to activate this device. NOTICE Advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. Fig.7 Mounting Dimensions 5.56 n Fig.8 3.50 mm) 200 in (m.2 ram) GREEN GROUND (50.8 ram) A SCREWS t Pt 2.34 in i.'Igr,p. ip; III I (59.4 mm)' _ Ali I I�,�_1 U-BOLT NUT *5.25 in. -�--- -- 5.25 in ••AM��VI (+1334mm) ���� ���� U-BOLT WASHER I� i�� ���� II Y'+''�'�� ��I PIPE SADDLE . mai. PIPE • , ,, I ���t.+li_�..;l. (A PLASTIC PADDLE I 1w wtiu , t ;)' ,4 iom iruu oun U-BOLT NOMINAL PIPE DIA.+1.75 in(+44.5 MM)FOR DN 50-DN 65 2-2.5 in - i�• OW ua-v NOMINAL PIPE DIA.+2.125 in(+54.0 MM)FOR DN 80—DN 200 3-8 in PRINTED IN USA MFG.#5401146-REV L PAGE 3 OF 4 3/09 P POTTER VANE TYPE WATERFLOW 0 The Symbol of Protection ALARM SWITCH WITH RETARD Maintenance Inspect detectors monthly. If leaks are found, replace the detector. The VSR waterflow switch should provide years of trouble-free service. The retard and switch assembly are easily field replaceable.In the unlikely event that either component does not perform properly,please order replacement retard switch assembly stock#1029030(see Fig.6).There is no maintenance required,only periodic testing and inspection. Retard/Switch Assembly Replacement(See Fig.6) NOTICE The Retard/Switch Assembly is field-replaceable without draining the system or removing the waterflow switch from the pipe 1. Make sure the fire alarm zone or circuit connected to the waterflow switch is bypassed or otherwise taken out of service. 2. Disconnect the power source for local bell(if applicable). 3. Identify and remove all wires from the waterflow switch. 4. Remove the(2)mounting screws holding retard/switch assembly to the base.Do not remove the(2)retard housing screws. 5. Remove the retard assembly by lifting it straight up over the tripstem. 6. Install the new retard assembly.Make sure the locating pins on the retard/switch assembly fit into the locating pin bosses on the base. 7. Re-install the(2)original mounting screws. 8. Reconnect all wires.Perform a flow test and place the system back in service. Fig.6 REMOVE(2)ORIGINAL MOUNTING SCREWS HOLDING RETARD/SWITCH ASSEMBLY TO BASE BREAKOUTTHIN SECTIONOF COVER WHEN WIRING BOTH SWITCHES FROM ONE CONDUIT ENTRANCE. (2)ORIGINAL MOUNTING I CREWS I- I RETARD/SWITCH ASSEMBLY WI eI�a \ ftHr.i.mmui_=1r % lip `. ; W" <x)LOCATINGPINS I , Ff ., (2)LOCATING PIN I ' DO NOT REMOVE 1 BOSSES IN BASE (2)RETARD HOUSING I ti 1 SCREWS � a �% _r_d�711171 I' IM �� ' i■■ t�.d'A'' x�,-i-c�r/thy% BAS �OJL'G'� I-, saw*° j o, vorDWG#1146-10 Removal of Waterflow Switch • lo prevent accidental water damage,all control valves should be shut tight and the system completely drained before waterflow detectors are removed or replaced. • Turn off electrical power to the detector,then disconnect wiring. • Loosen nuts and remove U-bolts. • Gently lift the saddle far enough to get your fingers under it. With your fingers,roll the vane so it will fit through the hole while continuing to lift the waterflow detector saddle. • Lift detector clear of pipe. PRINTED IN USA MFG.45401146-REV L PAGE 4 OF 4 3/09 • P PO 1 1 ER BELLS The Symbol of Protection / PBA-AC& MBA-DC L,ULC,and FM Approved izes Available: 6"(150mm),8"(200mm)and 10"(250mm) Voltages Available: 24VAC 44 120VAC if 12VDC(10.2 to 15.6)Polarized 1. 24VDC(20.4 to 31.2)Polarized ); Service Use: Fire Alarm slit' General Signaling Burglar Alarm • Environment: Indoor or outdoor use(See Note 1) -40°to 150°F(-40°to 66°C) (Outdoor use requires weatherproof backbox.) Termination: AC Bells-4 No. 18 AWG stranded wires `" ®O Finish: Red powder coati DC ng Bells-Terminal strip Optional: Model BBK-1 weatherproof backbox Model BBX-I deep weatherproof backbox These vibrating type bells are designed for use as fire,burglar or general Notes: signaling devices. They have low power consumption and high decibel 1. Minimum dB ratings arc calculated from integrated sound pressure ratings.The unit mounts on a standard 4"(101mm)square electrical box measurements made at Underwriters Laboratories as specified in UL for indoor use or on a model BBK-1 weatherproof backbox or BBX-1 Standard 464. UL temperature range is-30°to 150°F(-34°to 66°C). deep weatherproof backbox for outdoor applications. Weatherproof 2. Typical dB ratings are calculated from measurements made with a backbox model BBK-1,Stock No.1500001. conventional sound level meter and are indicative of output levels in an actual installation. 3. ULC only applies to MBA DC bells. Size inches Voltage Model Stock Current Typical dB at Minimum dB at (mm) Number Number (Max.) 10 ft.(3m)(2) 10 ft.(3m)(1) 6(150) 12VDC MBA126 1750070 .12A 85 76 8(200) 12VDC MBA128 1750080 .I2A 90 77 10(250) 12VDC MBA1210 1750060 .12A 92 78 6(150) 24VDC MBA246 1750100 .06A 87 77 8(200) 24VDC MBA248 1750110 .06A 91 79 10(250) 24VDC MBA2410 1750090 .06A 94 80 6(150) 24VAC PBA246 1806024* .17A 91 78 8(200) 24VAC PBA248 1808024* .17A 94 77 10(250) 24VAC PBA2410 1810024* .17A 94 78 6(150) 120VAC PBA1206 1806120* .05A 92 83 8(200) 120VAC PBA1208 1808120* .05A 99 84 10(250) 120VAC PBA12010 1810120* .05A 99 86 All DC bells are polarized and have built-in transient protection. *Does not have ULC listing. . .. In outdoor or wet installations,bell must be mounted with weatherproof backbox,BBK-1 or BBX-1.Standard electrical boxes will not provide a weatherproof enclosure.If the bell and/or assembly is exposed to moisture,it may fail or create an electrical hazard. Potter Electric Signal Company,LLC•2081 Craig Road,St.Louis,MO,63146-4161•Phone:800-325-3936/Canada888-882-1833•www.pottersignal.com ■ PRINTED IN USA MEG.#5400776-REV Y PAGE 1 OF 2 5/08 • P POTTER BELLS R The Symbol of Protection PBA-AC & MBA-DC Bells Dimensions Inches(mm) Wiring(rear view) Fig. 1 Fig.3 A.C.BELLS II:lIii wxlTE(ouTi10"(2SO) $„(2O0)1 R1 1 �I BLACK(OUT) CAUTIO N: WHEN ELECTRICAL SUPERVISION IS REQUIRED USE IN AND OUT LEADS AS SHOWN. 2 11/16" (68) MVO 776.1 NOTES: I.WHEN USING AC BELLS,TERMINATE EACH EXTRA WIRE SEPARATELY AFTER LAST BELL. 2 END-0F-LINE RESISTOR IS NOT REQUIRED ON AC BELLS. °WC/7M! Weatherproof Backbox Dimensions Inches(mm) Fig.2 FACP Box has one threaded 1/2"conduit entrance I�I�, -1 �`' VI1 Dep s 3,4- _ s va" s^ Lmmimi To Next Oaa) C�1 05;7) Devce or End-o£Line Resistor 3 4 D 34/68; _..] 4 1 1/4" 0081 Installation DwC.*2]-7 1. The bell shall be installed in accordance with NFPA 13,72,or local Al-U.The top of the device shall be no less than 90"AFF and I: not less than 6"below the ceiling. 2. Remove the gong. 3. Connect wiring(see Fig.3). R �D 4. Mount bell mechanism to backbox(bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong(be sure that the gong positioning pin,in the mechanism housing,is in the hole in the gong). 0 S" 6. Test all bells for proper operation and observe that they can ssx-1 ti be heard where required(bells must be heard in all areas as designated by the authority having jurisdiction).I t :z r A WAR .k . �T Failure to install striker do\\n kill prevent hell from operating. PRINTED IN USA MFG.#5400776-REV Y PAGE 2 OF 2 5/08 Pipe Hangers Installation Mil , Lir lir I Systems Product Submitted: LH Loop Hangers T + 1 I L, C 4.113 US LISTED N w I-a- 1/2" —2" Pipe 2-1/2" — 8" Pipe Feature/service: Pipe support manufactured to use minimum rod sizes permitted by NFPA for fire sprinkler piping. Size Range: 1/2" to 8" pipe sizes Material: Pre-galvanized carbon steel with zinc-electroplated insert nut, copper plated band and nut Approvals: Factory Mutual - FM (3/4" - 8") Listings: Underwriters Laboratories - UL, cUL Conforms with: Federal Specification WW-H-171 (Type 10) and Manufacturers Standardization Society MSS-SP-58 (Type 10) Installation: Install in accordance with ANSI/MSS-SP-69 Ordering/Technical Information: Wt. (Ibs) Tubing Rod Size Max allow Item No. Description* Box Qty per 100 Size RS H T W A CL load(lb)** 00257353 LH 1/2" 100 8 1/2" 3/8" 3-1/16" 18ga. 5/8" - - 300 00257354 LH 3/4" 100 10 3/4" 3/8" 3-1/8" 18ga. 5/8" - - 300 00257355 LH 1" 100 10 1" 3/8" 3-3/16" 18ga. 5/8" - - 300 00257356 LH 1-1/4" 100 10 1-1/4" 3/8" 3-1/2" 18ga. 5/8" - - 300 00257357 LH 1-1/2" 100 10 1-1/2" 3/8" 3-15/16" 18ga. 5/8" - - 300 00257358 LH 2" 100 11 2" 3/8" 4-1/2" 18ga. 5/8" - - 300 00257359 LH 2-1/2" 100 30 2-1/2" 3/8" 4-13/16" 14ga. 7/8" 15/16" 2-3/8" 525 00257360 LH 3" 50 34 3" 3/8' 5-5/8" 14ga. 7/8" 1-1/8" 2-7/8" 525 00257362 LH 4" 50 40 4" 3/8" 6-13/16" 14ga. 7/8" 1-1/4" 3-1/2" 650 00257364 LH 6" 20 140 6" 1/2" 9-7/8" 12ga. 3/4" 1-15/16" 5-1/4" 1000 00257365 LH 8" 15 170 8" 1/2" 12-1/2" 11ga. 3/4" 2-1/2" 6-13/16" 1000 *LH 3 1/2", and 5"available by special order. **Based on a safety factor of 3.5. Hilts. Outperform. Outlast. Hilti,Inc.(US)1-800-879-8000 www.us.hilti.com•Servicio at Cliente en espanol 1-800-879-5000•Hilti(Canada)Corporation 1-800-363-4458 www.ca.hilti.corn 10111 Il■ Installation Systems Product Submitted: Threaded Rod wowa ire j s, 0. , 4.44,44 Size Range: 1/4"-3/4" in 6' and 10' lengths Material: AISI 1008 - 1010 or ASTM A36 Steel Finish: Plain Oil or Zinc-Plated Ordering/Technical Information: Tube Weight Wt.(Ibs) Diam. Pitch Major Max allow Item No. Description Qty Lblft per pkg. In, Diameter Diameter Material tensile in in load(Ibr 00257963 1/4"-6'THREADED ROD- 50 .12 35.70 1/4-20 .2164-.2108 .2489-.2367 AISI 1008- 240 ZINC 1010 00257964 3/8"-6'THREADED ROD- 25 .30 42.60 3/8-16 .3331-.3266 .3737-.3595 AISI 1008- 610 ZINC 1010 00257965 1/2-6'THREADED ROD- 12 .50 38.80 1/2-13 .4485-.4411 .4985-.4822 AISI 1008- 1130 ZINC 1010 00257966 5/8"-6'THREADED ROD- 8 .84 39.80 5/8-11 .5644-.5561 .6234-.6052 AISI 1008- 1810 ZINC 1010 00257967 3!4"-6'THREADED ROD- 5 1.20 36.20 3/4-10 .6832-.6744 .7482-.7288 ASTM A36 2710 ZINC 00257968 114"-6'THREADED ROD- 50 .12 35.70 1/4-20 .2164-.2108 .2489-.2367 AISI 1008- 240 PLAIN 1010 00257969 3/8"-6'THREADED ROD- 25 .30 42.60 3/8-16 .3331-.3266 .3737-.3595 AISI 1008- 610 PLAIN 1010 00257970 1/Z'-6'THREADED ROD- 12 .50 38.80 1/2-13 .4485-.4411 .4985-.4822 AISI 1008- 1130 PLAIN 1010 00309386 114"-10'THREADED ROD- 50 .12 59.50 1/4-20 .2164-.2108 .2489-.2367 AISI 1008- 240 ZINC 1010 00309387 318"-10'THREADED ROD- 25 .30 71.30 3/8-16 .3331-.3266 .3737-.3595 AISI 1008- 610 ZINC 1010 00309388 1/2"-10'THREADED ROD- 12 .50 61.40 1/2-13 .4485-.4411 .4985-.4822 AISI 1008- 1130 ZINC 1010 00309389 5/8"-10'THREADED ROD- 8 .84 66.50 5/8-11 .5644-.5561 .6234-.6052 AISI 1008- 1810 ZINC 1010 00309390 314"-10'THREADED ROD- 5 1.20 60.00 3/4-10 .6832-.6744 .7482-.7288 ASTM A36 2710 ZINC 00309391 114'-10'THREADED ROD- 50 .12 59.50 1/4-20 .2164-.2108 .2489-.2367 AISI 1008- 240 PLAIN 1010 3/8"-10'THREADED ROD- AISI 1008- 0309392 PLAIN 25 .30 71.30 3/8-16 .3331-.3266 .3737-.3595 1010 610 00309393 112"-10'THREADED R0D- 12 .50 61.40 1/2-13 .4485-.4411 .4985-.4822 AISI 1008- 1130 PLAIN 1010 00309394 518"-10'THREADED ROD- 8 .84 66.50 5/8-11 .5644-.5561 .6234-.6052 AISI 1008- 1810 PLAIN 1010 00309395 3!4°-10'THREADED R0D- 5 1.20 60.00 3/4-10 .6832-.6744 .7482-.7288 ASTM A36 2710 PLAIN ** Per MSS SP-58, the maximum allowable tensile loads are based on an allowable tensile stress of 12,000 psi reduced by 25% resulting in 9,000 psi. The 12,000 psi allows for the interchangeability of the referenced rod materials. The 25% reduction is to allow for normal installation and service conditions. Hilti. Outperform. Outlast. HUH,Inc.(US)1-800-879-8000 www.us.hilti.com•Scrvicio al Cliente en espanol 1-800-879-5000•Hilti(Canada)Corporation 1-800-363-4458 www.ca.hiiti.com Upper Attachments Fig.58- Threaded Side Beam Bracket ®TOLCO Size Range: 3/8"-16 rod,pipe sizes 1/2" (15mm)thru 4"(100mm) B Material: Pre-Galvanized Steel /` Function: Practical and economical bracket used to support piping from wood, con- crete or steel beams. Features: Unique design allows rod to be easily threaded into bracket.Offset design a A permits unlimited rod adjustment. Center mounting hole will accept 3/8"and V2"fastener M i, bolts. Per NFPA 13: 1/2"(15mm)thru 2"(5omm)pipe requires 3/8"fastener,21/2"(65mm) ®b•s4 thru 4"(100mm)pipe requires V2'fastener.' \� Approvals: Underwriters Laboratories Listed in the USA(UL)and Canada(cUL),and �*\�� J Factory Mutual Engineering approved thru 4"(100mm)pipe. / C v Finish: Pre-Galvanized Order By: Part number and finish *Note: Additionally UL has listed the Fig.58 with fasteners 2-1/4"x 2"Lag Bolts as shown in table below. Up to 4 (10 o4•"(10G Ming 0mm)pipe Per NFPA t t 1-a/e"or 1/2"Lag Bolts Up to 4"(100mm)pipe t , 2-1116x2" Drive Screws ( '/2 (15mm)-4'(100mm)pipe le t O' ar ei.:, .•- 4, ----------- ,ic 4..) CODS D 2-1114x1"Or1/4"X1" Tek Type Screws Into Min.16 Gauge Steel m Up to 4"(100mm)pipe e UL Listed Fastener Table e E Pipe Size Qty Fastener Type Material Bolt&Hex Nut as Up to 4"(100mm)pipe m 2" 2 #16 x 2"Drive screws Wood a 2" 1 3/8"Lag bolt Wood 21/2"-4" 1 1/2"Lag bolt Wood 31/2" 2 1/4"x 11/z"Lag bolts Wood � a _ 4" 2 1/4"x 2"Lag bolts** Wood �- 4" 2 #14 x 1"or 1/4"x 1"Tek type screws Metal(15 gauge) ,� 4" 2 #14 x 1"or 1/4"x 1"Tek type screws Metal(16 gauge) ... *"No pre-drilling Part No. Pipe Size Rod A B C Max. Rec.Load Approx.Wt./100 in. (mm) Size in. (mm) in. (mm■ in. (min) Lbs. (kN) Lbs. (kg) _'` 1/2"-4" (15-100) 3/B"-16 KM= 11/2 (38.1) 11/a" (28.6) 300'** (1.33) 14 (6.3) ***With Safety Factor of 5. All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. p Pipe Hangers&Supports 218 B Line by EA•N Upper Attachments B3199R - Ceiling Flange B3199RCT - Ceiling Flange Dura-Copper Coated B 27/e" Dverall Height (MO) Size Range: 3/a"-16&1/2"-13 rod 2 B (50.81 Material: Malleable Iron (Stainless Steel Type 304 available) For'/a"Flat Head Standard Finish: Plain or Electro-Galvanized Machine Screws B3199RCT is DURA-COPPER'"'coated or Wood Screws Function: Designed for attaching a hanger or support rod to 13/e° beams,ceilings,or walls. 3d9j Order By: Part number and finish. A Ile (Rod or Pipe Thread) Hanger Rod or Pipe Not Included 4401* B3199RCT B3199R Part No. Thread Size B Design Load Approx.Wt./100 A in. (mm) Lbs. (kN) Lbs. (kg) B3199R-3/a B319911CT-31s 3/8"-16 7/1s" (11-1) 180 (.80) 13 (5.9) B3199R-1/2 B3199RCT-1/2 1/2"-13 1/2' (12.7) 180 (.80) 17 (7.7) Fig. 78 - All Steel Ceiling Plate ®TOLCO c Size Range: 3/8"-16 rod a A Material: Pre-Galvanized Steel Function: Attachment to wood beams,ceilings,metal decks �p or walls. Can also be welded to steel beams. _ Approvals: Underwriters Laboratories Listed in the USA(UL) and Canada(cUL).Additionally,UL has listed the Fig.78 with `l► Amo fasteners as shown in the table below. E Finish: Plain.Contact B-Line for alternative finishes and / D materials. // (2 Holes Order By: Part number,rod size and finish C �t. U$ v -! `m E US Patent#5,702,077 WEB -. - cos > u -' ✓ O ai UL Listed Fastener Table 6 Pipe Size City Fastener Type Material E P, 1/2"-2" 2 #14 x 11/4"A-point hex-washer-head sheet metal screw Wood °' 21/2"-4" 2 1/4"x 11/2"wood screws* Wood 1/2"-2" 2 1/4"x 1"tek screws Metal(18 gauge) 1/2'-2" 2 #14 x 11/4"A-point hex-washer-head sheet metal screw Wood 1/2'-2" 2 #14 x 2"A-point-hex-washer-head sheet metal screw Wood thru 5/8"gyp board .,, *No pre-drilling Part No. Pipe Size A B C Hole Dia. D Thread Size Design Load Approx.Wt./100 in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) E Lbs. (kN) Lbs. (kg) 78-3/8 l/2"-2° (15-60) 3" (76.2) 21/8" (54.0) 11/a" (28.6) 5/16° (7.9) 3/8"-16 150* (0.67) 15 (6.8) Consult Factory For Data All dimensions in charts and on drawings are in inches.Dimensions shown in parentheses are in millimeters unless otherwise specified. B-Line Pipe Hangers&Supports 214 by E:T•H _ BEAM CLAMPS L Fig. 345 FUNCTION: Designed for attaching hanger rod to the top flange of a beam or bar joist at g least 3/16 inch(4.76mm)thick,and where the flange thickness does not TOP BEAM CLAMP exceed 3/4 inch(19.05mm).The open U design permits rod adjustment. APPROVALS: Underwriters'Laboratories Listed in the U.S.(UL),Canada(CUL)and E Factory Mutual Approved.Complies with Federal Specifications A-A-1192A (Type 19)and Manufacturers'Standardization Society ANSI/SP-69 and ANSI/SP-58(Type 19). o l MATERIAL: Low carbon steel with hardened steel cup point set screw and locknut FINISH: Pre-galvanized ORDERING: Specify figure number. C — 3/4" I Rod Max. Max. Rec. (19.05 Size Pipe Load Wt.Each 4 A B C D E Size j lbs. kN lbs. kg 3/8 3/4 (19.05) 19/1611(39.69) 11/2 (38.10) 9/16 1(14.29) 4 1 (100) '1 610 (251) .20 (.09) A Set Screw Tor ue Note: When a torque wrench is Nominal 3/8 Caution should be unavailable, the setscrew should be Thread Size taken not to over tw- FM Rec. in-lbs 60 tighten the set screw tightened so it contacts the I-beam and !� 5 <> �I Torque N-m (6.8) then an additional 1/4 to 1/4 turn added. UTEO 3 gillNote:Set screw must contact the sloped side of the I-beam,channel,or other applicable building structure. Clamp must always be installed in top orientation,with the arrow mark on clamp pointing up. The following illustration displays the only acceptable installation positions.On parallel flange surfaces,the clamp may be attached to the upper or lower flange but must be in the top orientation as shown. Unless otherwise specified,all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. E PHD Manufacturing,Inc. BEAM CLAMPS I ��\ 1L°1 FUNCTION: Designed for use with Fig.345,Fig.350,and Fig.360 to offer more secure Fig. 359 fastening of beam damps to beam where seismic protection is provided. APPROVALS: Underwriters'Laboratories Listed in the U.S.(UL)and Canada(CUL)for 3/8" RETAINING STRAP and 1/2"rod sizes only. Meets NFPA13 requirements for hangers and fasteners For Fig. 345,350,&360 subject to earthquakes. MATERIAL: Low carbon steel FINISH: Electro-galvanized _- ORDERING: Specify rod size,length,finish and figure number. -4.2.-,- '' usrm NOTE: 2 inches(50.8)should be added to beam flange width to determine length. \-,._. �'� Wt.Each �4� ....-"-F Vie+ Len th C r Rod Size 41/2(114.3) 6(152A) 8(203.2) 10(254.0) 12(304.8) 14(355.6) C 3/3&1/2 .09 (.04) .12 (.05) .15 1(.07) .21 (.10) .22 (.10) .29 (.13) 5/5 .19 (.09) .25''.(.11) .34 (.15) .42 (.19) .50 (.23) .59 (.27) v / 3/4 .19 (.09) .25 (.11) .33 (.15) .41 (.19) .49 (.22) .57 (.26) (:i rle .28 (.23) .37.(.17) .50 (.23) .62 (.28) .75 (.34) .87 (.39) ..r.-----_,-. _ at ____". .. NOTE:Use jam nut over hanger rod to secure retaining strap. Available in stainless steel.To order,specify 304 or 316 and add suffix SS to figure number. ( f Price on request. Unless otherwise specified,all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters ) l PHI)Manufacturing,Inc. Seismic Bracing Components SWAY BRACE FITTINGS r D FUNCTION: Designed for bracing pipe against sway and seismic disturbance.The pipe attachment component of a sway brace system used in conjunction Fig. 010 with a PHD Manufacturing structural attachment fitting,and joined together with a bracing pipe element forms a complete sway brace SWAY BRACE assembly. Sway brace assemblies are intended to be installed in PIPE ATTACHMENT accordance with NFPA 13 and the manufacturer's installation instructions. SIZE: Pipe size 1"thru 6". Pipe size used for bracing 1"or 114"Schedule 40 IP. FINISH: Electro-galvanized -- MATERIAL: Low Carbon Steel INSTALL: Place over the pipe to be braced,adjust brace angle,and insert bracing ' pipe through opening leaving a minimum of 1"extending from attachment.Brace pipe can be installed on top or bottom of pipe to be I - braced but must be a minimum of 6"away from a pipe joint. ighten nuts - down evenly until hex heads break off. f � APPROVALS: Underwriters Laboratories listed for US and Canada V Factory Mutual approved a5TE0 Listed for use with NFPA and PHD sway brace components only ORDERING: Specify figure number,brace pipe size,and sprinkler pipe size FM Maximum Design Load Brace Pipes 1"or 1 1/4" UL Maximum Design Load (GB/T3091,EN10255H,or JISG3454) Weight Ea. Pipe Size Brace Angle 1"(25mm) 1 1/4"(32mm) SCH 10,40 From Vertical Pipe Size Brace Pipe Brace Pipe &Flow Pipe (Degrees) lbs. kN 30°-44° 340 (1,51) SCH 40 lbs. kN lbs. kg lbs. kg 45°-59° 480 (2.13) *1 (25) 1000 (4.45) 0.71 (0.32) 0.75 (0.34) 1 (25) 60°-74° 590 (2.62) 1 1/4 (32) 1000 (4.45) 0.76 (0.34) 0.79 (0.36) 75°-90° 660 (2.93) 1 1/2 (40) 1000 (4.45) 0.79 (0.38) 0.82 (0.37) 30°-44° 350 (1.55) 2 (50) 1000 (4.45) 0.84 (0.38) 0.88 (0.40) 11/4 (32) 45°-59° 500 (2.22) 60°-74° 610 (2.71) 21/2 (65) 1000 (4.45) 0.90 (0.41) 0.94 (0.43) 75°-90° 680 (3.02) 3 (80) 1000 (4.45) 0.98 (0.44) 1.02 (0.46) 30°-44° 290 (1.28) 4 (100) 1000 (4.45) 1.10 (0.50) 1.14 (0.52) 11/2 (40) 45°-59° 420 (166) 60°-74° 510 (2.26) 6 (150) 1600 (7.12) N/A N/A 1.40 (0.63) 75°-90° 570 i(2.53) *Restraint only 45°-59° 550 (2.44) 2 (50) 80°-74° 870 (2,98) 75°-90° 750 (3.33) 30°-44° 440 (1.95) 21/2 (65) 45°-59° 620 (2.75) 60°-74° 760 (3.38) 75°-90° 850 (3.78) 30°-44° 470 (2.09 3 (80) 45°-59° 660 (2.93) 60°-74° 810 (3.33) 75°-90° 910 (4.04) 30°-44° 430 (1.91) 4 (100) 45°-59° 610 (2.71) 80°-74° 750 (3.33) 75°-90° 840 (3.73) 30°-44° 250 (1.11) *6 (150) 45°-59° 35D (1.55) 60°-74° 430',(1.91) 75°-90° 48D (2.13) *1114"brace size only Unless otherwise specified,al.dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. A... ..i PHD Manufacturing, Inc. 44018 Columbiana-Waterford Road Columbiana, Ohio 44408-9481 Phone: 800-321-2736 . 330-482-9256 Fax: 330482-2763 Web: www.phd-mfg.com • FIG.010 SWAY BRACE PIPE ATTACHMENT Pipe Braced: 1", 1 1/4", 1 1/2",2", 2 1/2", 3",4",6" Bracing: 1"Or 1 1/4"SCH40 steel pipe Function: Designed for bracing pipe against sway and seismic disturbance.The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting, and joined together with a bracing pipe element forms a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada(1"system pipe size listed as a restraint only) Factory Mutual approved Listed for use with NFPA and PHD sway brace components only Material: Low Carbon Steel Installation: Place over the pipe to be braced,adjust brace angle,and insert bracing pipe through opening leaving a minimum of 1"extending from attachment. Brace pipe can be installed on top or bottom of pipe to be braced but must be a minimum of 6"away from a pipe joint. Tighten nuts down evenly until hex heads break off ""-itii le. -"A\N 1/11)-X, 4016°. a V\1111) tii, UL Maximum Design Loads Brace Pipe Pipe Size Size Schedule 40 Schedule 40 lbs. 1* 1 & 1 1/4 1000 1 1/4 1 & 1 1/4 1000 1 1/2 1 & 1 1/4 1000 2 1 & 11/4 1000 2 1/2 1 & 1 1/4 1000 3 1 & 1 1/4 1000 4 1 & l 1/4 1000 6 1 1/4 1600 *UL listed as a restraint device only. FM Approved Loads Allowable Horizontal Capacity Per Installation Angle(lbs.) Brace Pipe Pipe Brace Angle From Vertical Size Orientation Pipe Size Schedule 30°-44° 45°-59° 60°-74° 75°-90° Schedule 40 Lateral 1 LW, 10,40 340 480 590 660 1"or 1 1/4" Lateral 1 1/4 LW, 10,40 350 500 610 680 1"or 1 1/4" Lateral 1 1/2 LW, 10,40 290 420 510 570 1"or 1 1/4" Lateral 2 LW, 10,40 390 550 670 750 1"or 1 1/4" Lateral 2 1/2 LW, 10,40 440 620 760 850 1"or 1 1/4" Lateral 3 LW, 10,40 470 660 810 910 1"or 1 1/4" Lateral 4 LW, 10,40 430 610 750 840 1"or 1 1/4" Lateral 6 LW, 10,40 250 350 430 480 1 1/4" NOTE:LW above refers to FM Approved Lightwall pipe,commonly referred to as Schedule 7. These ratings may also be applied to EN 10220 and GB/T 8163 pipe. Schedule 10 above may be applied to GB/T 3091,GB/T 3092,EN 10255 M and H,JIS G3452. Schedule 40 above may be applied to GB/T3091,EN10255H or JISG3454 brace pipe. The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut&Accessories • Pipe Clamps • Beam Clamps • Shields SWAY BRACE FITTINGS -- t FUNCTION: Designed for bracing pipe against sway and seismic disturbance.The pipe attachment component of a sway brace system used in conjunction Fig. 015 with a PHD Manufacturing structural attachment fitting,and joined together with a bracing pipe element forms a complete sway brace LARGE SWAY BRACE assembly. Sway brace assemblies are intended to be installed in PIPE ATTACHMENT accordance with NFPA 13 and the manufacturer's installation instructions. SIZE: Pipe size 2-1/2"thru 8". Pipe size used for bracing 1"or 1 114"Schedule 40IP. FINISH: Electro-galvanized MATERIAL: Low Carbon Steel \ \\ INSTALL: Place over the pipe to be braced,adjust brace angle,and insert bracing \` pipe through opening leaving a minimum of 1"extending from attachment.Brace pipe can be installed on top or bottom of pipe to be / braced but must be a minimum of 6"away from a pipe joint.Tighten two hex head cone point set bolts until heads bottom out on attachment, ensuring proper torque has been applied. APPROVALS: Underwriters Laboratories listed for US and Canada(2 1/2"thru 6"only) Factory Mutual approved 10 Listed for use with NFPA and PHD sway brace components only ORDERING: Specify figure number,brace pipe size,and sprinkler pipe size cOas 4( -r FM Maximum Design Load 0 Brace:1"Thru 2"SCH40 Pipe _(GB/T3091,EN10255H,or JISG3454) Weight Ea. UL Maximum Design Load Pipe Size Brace Angle 1"(25mm) 1 1/4"(32mm) Pipe Size SCH 10,40 From Vertical Brace Pipe Brace Pipe SCH 10&40 lbs. kN &Flow Pipe (Degrees) lbs. kN _ lbs. I kg lbs. I kg 2 1/2 (65) 1000 (4.45) 30°-44° 1020 (4.53), 3 (80) 1000 (4.45) 21/2 (65) 45°-59° 1440 (6.40) 1.31 (0.59) 1.49 (0.68) 80°-74° 1770 4 (100) 1000 (4.45) 75°-90° 1970 (8.76) 6 (150) 1600 (7.12) 30°-44° 1080 (4.80) 3 (80) 45°-59° 1530 (6.80) 1.40 (0.64) 1.57 (0.71) 60°-74° 1870 (8.31) 75°-90° i 2090 (9.29) 30°-44° 1020 (4.53) 4 (100) 45°-59° 1450 (6,44) 1.53 (0.89) 1.70 (0.77) 60°-74° 1770 (7.87) 75°-90° 1980 (8.80) 30°-44° 640 (2.84), 6 (150) 45°-59° 900 (4.00) 1.81 (0.82) 1.98 (0.90) 60°-74° 1110 (4.93) 75°-90° 1240 (5.51) 30°-44° 570 (2.53) 8 (200) 45°-59° 810 (3.60) 2.07 (0.94) 2.24 (1.02) 80°-74° 990 (4.40) 75°-90° 1100 (4.89) Unless otherwise specified,all dimensions on drawings and in charts are in inches and direns'ons shown in parentheses are in millimeters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. • 44018 Columbiana-Waterford Road Columbiana, Ohio 44408-9481 Phone: 800-321-2736 • 330-482-9256 ' '-1 0 Fax: 330-482-2763 Web: www.phd-mfg.com FIG.015 LARGE SWAY BRACE PIPE ATTACHMENT Pipe Braced: 2 1/2",3",4",6",8" Bracing: 1"Or 1 1/4"SCH40 steel pipe Function: Designed for bracing pipe against sway and seismic disturbance.The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting, and joined together with a bracing pipe element forms a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada;Sizes 2 1/2"through 6" Factory Mutual approved; Sizes 2 1/2"through 8" Listed for use with NFPA and PHD sway brace components only Material: Low Carbon Steel Installation: Place over the pipe to be braced,adjust brace angle,and insert bracing pipe through opening leaving a minimum of 1"extending from attachment.Brace pipe can be installed on top or bottom of pipe to be braced but must be a minimum of 6"away from a pipe joint.Tighten two hex head cone point set bolts until heads bottom out on attachment, ensuring proper torque has been applied. 0 UL Maximum Desi,n Loads Pipe Pipe Brace Brace Size Schedule Size Schedule lbs. 2 1/2 40 1 & 1 1/4 40 1000 3 10 & 40 1 & 1 1/4 40 1000 4 10 & 40 1 & 1 1/4 40 1000 6 10 & 40 1 & 1 1/4 40 1600 FM Approved Loads Allowable Horizontal Capacity Per Installation Angle(lbs.) Pipe Pipe Brace Angle From Vertical Orientation Size Schedule 30°-44° 45°-59° 60°-74° 750-90° Brace Member Lateral 2 1/2 LW, 10,40 1020 1440 1770 1970 1"or 1 1/4"Schedule 40 Pipe Lateral 3 LW, 10,40 1080 1530 1870 2090 1"or 1 1/4"Schedule 40 Pipe Lateral 4 LW, 10,40 1020 1450 1770 1980 1"or 1 1/4"Schedule 40 Pipe Lateral 6 LW, 10,40 640 900 1 110 1240 1"or 1 1/4"Schedule 40 Pipe Lateral 8 LW, 10,40 570 810 990 1100 1"or 1 1/4"Schedule 40 Pipe NOTE:LW above refers to FM Approved Lightwall pipe,commonly referred to as Schedule 7. These ratings may also be applied to EN10220 and GB/T 8163 pipe.Schedule 10 above may be applied to GB/T 3091,GB/T 3092,EN 10255 M and H,J1S G3452. Schedule 40 above may be applied to GB/T3091,EN 10255H or JISG3454 brace pipe. The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut&Accessories • Pipe Clamps • Beam Clamps • Shields STRUCTURE ATTACHMENT FITTINGS 4 o FUNCTION: Designed for bracing pipe against sway and seismic disturbances. Universal swivel design allows for attachment at any surface angle Fig. 030 combined with concentric loading. Structure attachment fitting designed to use 1"thru 2"SCH 40 pipe,structural steel,and PHD 12 gauge strut C-CLAMP channel(1001&1201)as sway bracing elements. No bracing member STRUCTURAL thicker than 3/8"can be used in conjunction with this product. Utilize the Fig.030 with a PHD Manufacturing pipe attachment fitting and a bracing ATTACHMENT element to form a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. 1 SIZE: 1/2"mounting hole J dos Braces up to 8"Pipe MAX FINISH: Electro-galvanized MATERIAL: Ductile Iron and Low Carbon Steel INSTALL: Mount device to structure then insert brace element into fitting against back of jaw. Tighten set screw finger tight,then tighten until hex head breaks off. Adjust attachment to proper brace angle. APPROVALS: Underwriters Laboratories listed for US and Canada Factory Mutual approved usr® Listed for use with NFPA fastener tables and PHD sway brace components only ORDERING: Specify figure number UL Maximum Design Loads(Up to 8"Pipe) FM Maximum Design Load Lateral&Longitudinal Assemblies For Bracing SCH 10,40&Flow Pipe Member Weir ht Ea. Brace Angle Brace Member Thickness Member Length lbs. kN lbs. kg Brace From Vertical 1"Thru 2"Pipe SCH 40 Refer to NFPA13 2015 (8.98) Member (Degrees) lbs. kN Structural Steel 3/8"thick MAX Refer to NFPA13 2015 (8.96) 30°-44° 1270 (5.64) 1001 Series Strut 12 Ga. See Chart Below 2015 (8.96) 1.46 (0.66) 1"Thru 2" EN102091, 45°-59 2040 (9.07) SCH 40 Pipe N10255H, 60°74° 2450 1201 Series Strut 12 Ga. See Chart Below 2015 (8.96) or JISG3454) (10.89) 75°-90° 2740 (12.18) 30°-44° 900 (4.00) 1/4"Thru 3/8"Thick 45°-59° 1280 (5.69) Structural Steel 60°-74° 1570 (6.98) 75°-90° 1750 (7.78) 30°-44° 1070 (4.75) PHD 12 Gauge 45°-59° 1440 (6.40) Strut Channel 1001&1201 60°-74° 1740 (7.73) _. 1 75°-90° 1940 (8.62) PHD Strut Channel Maximum Horizontal Load 90°From Vertical Strut = 100 200 300 Ur Fig.# r Max lbs. kN Max lbs. kN Max lbs. kN 1001 0.580 (14.73) 58° (1473.2) 4670 (20.77) 116" (2946.4) 1165 (5.18) 174" (4419.6) 518 (2.301 1201 0.297 (7.54) 29" (736,6) 3260 (14.50) 59" (1498.6) 785 (3.49) 89" (2260.6) 345 (1.53) Unless otherwise specified,all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. 44018 Columbiana-Waterford Road Columbiana, Ohio 44408-9481 " Phone: 800-321-2736 . 330-482-9256 ' A Fax: 330-482-2763 Web: www.phd-mfg.com FIG.030 C-CLAMP STRUCTURAL ATTACHMENT Pipe Braced: 8"Pipe MAX Bracing: 1"thru 2"SCH 40 pipe, structural steel,and PHD 12 gauge strut channel(1001 & 1201) Function: Designed for bracing pipe against sway and seismic disturbances. Universal swivel design allows for attachment at any surface angle combined with concentric loading. Structure attachment fitting designed to use 1"thru 2"SCH 40 pipe,structural steel,and PHD 12 gauge strut channel (1001 & 1201)as sway bracing elements. No bracing member thicker than 3/8"can be used in conjunction with this product. Utilize the Fig.030 with a PHD Manufacturing pipe attachment fitting and a bracing element to form a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with NFPA13 fastener tables and PHD sway brace components only Material: Ductile Iron and Low Carbon Steel Installation: Mount device to structure then insert brace element into fitting against back of jaw. Tighten set screw finger tight,then tighten until hex head breaks off. Adjust attachment to proper brace angle. UL Maximum Design Loads(Up to 8"Pipe) Member Brace Member Thickness Member Length lbs. 1"Thru 2"Pipe SCH 40 Refer to NFPA13 2015 NFPA13 Structural Steel 3/8"thick MAX Refer to NFPA13 2015 1001 Series Strut 12 Ga. See Chart Below 2015 1201 Series Strut 12 Ga. See Chart Below 2015 FM Maximum Design Load For Bracing SCH 10,40&Flow Pipe Brace Angle Brace From Vertical Member (Degrees) lbs. (GB/T3091, 30°-44° 1270 1"Thru 2" EN10255H, 45°-59° 2040 SCH 40 Pipe or JISG3454) 60°-74° 2450 75°-90° 2740 30°-44° 900 1/4"Thru 3/8"Thick 45°-59° 1280 Structural Steel 60°-74° 1570 75°-90° 1750 30°-44° 1070 PHD 12 Gauge 450-59° 1440 Strut Channel 60°-74° 1740 1001 & 1201 750-900 1940 Strut Max.Horizontal Load lbs.)90°From Vertical Fig.# r 1/r= 100 200 300 1001 0.580 58" 4670 116" 1165 174" 518 1201 0.297 29" 3260 59" 785 89" 345 NOTE:Use NFPA13 table"Allowable Horizontal Load on Brace Assemblies Based on the Weakest Component of the Brace Assembly"reduction factors for maximum loads at varying angles. Refer to www.phd-mfg.com regarding further strut channel details The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut&Accessories • Pipe Clamps • Beam Clamps • Shields ISWAY BRACE FITTINGS Alitill FUNCTION: Designed for bracing pipe against sway and seismic disturbance. Versatile design allows for attachment at any angle and the ability to be Fig. 031 used in a lateral or longitudinal bracing configuration. The pipe attachment component of a sway brace system used in conjunction with a CLAMPING PHD Manufacturing structural attachment fitting and joined together PIPE ATTACHMENT with a bracing element form a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. SIZE: Pipe sizes 2"thru 8". Can use 1"thru 2"SCH 40 pipe,structural steel,and PHD 12 gauge strut -a' channel(1001&1201)as sway bracing elements. FINISH: Electro-galvanized CO MATERIAL: Ductile Iron and Low Carbon Steel,Grade 5 clamping bolts )/ us 41> -- INSTALL: Place attachment around pipe to be braced,positioning brace ""�7 FM Maximum Design Load ____ attachment as needed,then tighten clamping bolts and nuts Brace:1"Thru 2"SCH40 Pipe finger tight. Insert brace component into fitting against back (GB/T3091,EN10255H,or JISG3454) of jaw. Tighten set screw finger tight,adjust brace angle as Pipe Size Brace Angle SCH 10,40 From Vertical Lon.itudinal Weight Ea. needed,then tighten set screw until hex head breaks off. &Flow Pipe (Degrees) 1 lbs.I kN lbs. kg Then evenly torque clamping bolts until hex portion of 30°-44° 1370 (6.09) clamping nuts break off. 45 0-59° 1930 (6.58) APPROVALS: Underwriters Laboratories listed for US and Canada 2 (50) 2.60 (1.18) 60°-74° 2370 (10.54) Factory Mutual approved 75°-90° 2810 (12.49) Listed for use with PHD sway brace components only 30°44° 1500 (8.67) ORDERING: Specify figure number and sprinkler pipe size 45°-59° 2120 (9.43) UL Maximum Design Loads 21/2 (65) 2.77 (1.P6) All Pipe Sizes,SCH 10&40(3 112 SCH 40 only) 60°-74° 2600 (11.56) Lateral&Longitudinal Assemblies _ ] 75°-90° 2900 (12.89) Member 30°-44° 1370 (6.09) Brace Member Thickness Member Length lbs. kN 1 45°-59° 1930 (8.58) 1'Thru 2"Pipe SCH 40 Refer to NFPA13 2015 (8.96) 60°-74° 2370 (10.54) Structural Steel 1/4"&3/8"thick Refer to NFPA13 2015 (8.96) 75°-90° 2810 (12.49) 1001 Series Strut 12 Ga. See Chart Below 2015 (8.96) 30°-44° 1370 (6.09) 1201 Series Strut 12 Ga. See Chart Below 2015 (8.96) 3 1/2 (90) 45°-59° 1930 (8.58) 3.13 (1.42) FM Maximum Design Load(All Sizes) 60°-74° 2370 (10.54) For Bracing SCH 10,40&Flow Pipe 75°-90° 2810 (12.49) Brace "'' 30°-44° 1370 (8.09) . Angle "' 45°-59° 1930 8.58 B (race Member Direction (Degrees) lbs. 1 kN " 4 (100) ) 3.30 (1.50) 30°-44° 1270 (5.64) 60°-74° 2370 (10.54) 1"Thru 2" (GB/T3091, 45°-59° 1800 (9.07) 75°-90° 2810'(12.49) SCH 40 Pipe EN10255H, Lateral 30°-44° 1370 (6.09) or JISG3454) 60°-74° 2200 (10.89) - 75°-90° 2460 (12.18) 5 (125) 45°-59° 1930 (8.56) 4.57 (2.07) 60°-74° 2370 (10.54) 30°-44° 900 (4.00) 75°-90° '2810 (12.49) ■ 1/4"Thru 3/8"Thick Lateral& 45°-59° 1280 (5.69) 30°-44° 1410 (6.27) Structural Steel Longitudinal 60°-74" 1570 (6.98) 6 (150) 45°-59° 2000 (8.89) 5.42 (2.46) 75°-90° 11750 (7.78) 60°-74° 2450 (10.89) 30°-44° 1070 (4.75) 75°-90° 2730 (12.14) PHD 12 Gauge Lateral& 450-59° 1440 (6.40) 30°-44° 1320 (5.87) Strut Channel Longitudinal 45°-59° 1870 8 31) 1001&1201 60°-74° ( 1740. (7.73) 8 (200) . 8.52 (3.86) _ 75°-90° 1940 (8.62) 60°-74° 2290 (10.18) -- - -- 75°-90° 2550 (11.34) PHD Strut Channel Maximum Horizontal Load 90°From Vertical Strut 100 200 300 Fig.# r 1/r= Max lbs. kN Max lbs. kN Max lbs. kN ' 1001 0.580104.73)_ 58' (1473.2) 4670 .(2077) 116"1(2946.4) 1165 (5.18) 174'I(4419.6) 518 (2.30) 1201 0.2971 (7.54) 29" (736.6) 3260_(14.50) 59" 1(1498.6) 785 (3.49) 89" 1(2260.6) 345 (1.53) Unless otherwise specified,al dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. 44018 Columbiana-Waterford Road Columbiana,Ohio. 44408-9481 330-482-2763 A Phone: Fax: 330-482-2763 Web:www.phd-mfg.com FIG.031 CLAMPING PIPE ATTACHMENT Pipe Braced: 2",2 1/2",3",3 1/2",4",5",6",8" Bracing: 1"thru 2"SCH 40 pipe,structural steel,and PHD 12 gauge strut channel(1001 & 1201) Function: Designed for bracing pipe against sway and seismic disturbance. Versatile design allows for attachment at any angle and the ability to be used in a lateral or longitudinal bracing configuration. The pipe attachment component of a sway brace system used in conjunction with a PHD Manufacturing structural attachment fitting and joined together with a bracing element forming a complete sway brace assembly. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with PHD sway brace components only Material: Ductile Iron and Low Carbon Steel,Grade 5 clamping bolts Installation: Place attachment around pipe to be braced,positioning brace attachment as needed,then tighten clamping bolts and nuts finger tight. Insert brace component into fitting against back of jaw. Tighten set screw finger tight,adjust brace angle as needed,then tighten set screw until hex head breaks off. Then evenly torque clamping bolts until hex portion of clamping nuts break off. 4 21 30 ,I - 1 1 t ° 1 30-90 1 Front View Side View Longitudinal Lateral III.Maximum Design Loads Pipe Sizes 2"thru 8"SCH 10&40(3 1/2 SCH 40 only) Lateral&Longitudinal Assemblies Brace Member Member Thickness Member Length Max.Design Load 1"Thru 2"Pipe SCH 40 Refer to NFPA13 2015 Structural Steel 1/4"to 3/8"thick Refer to NFPA13 2015 1001 Series Strut 12 Ga. See Chart Below 2015 1201 Series Strut 12 Ga. See Chart Below 2015 FM Maximum Design Loads Allowable Horizontal Capacity Per Installation Angle(lbs.) Pipe Brace Angle From Vertical Brace Orientation Pipe Size Schedule 30°-44° 45°-59° 60°-74° 75°-90° Member Lateral 2,2 1/2,3,3 1/2,4,5,6,8 LW, 10,40 1270 1800 2200 2460 1"to 2"Schedule 40 Pipe Longitudinal 2 LW, 10,40 1370 1930 2370 2810 1"to 2"Schedule 40 Pipe Longitudinal 2 1/2 LW, 10,40 1500 2120 2600 2900 1"to 2"Schedule 40 Pipe Longitudinal 3,3 1/2,4 LW, 10,40 1370 1930 2370 2810 1"to 2"Schedule 40 Pipe Longitudinal 5,6 LW, 10,40 1410 2000 2450 2730 1"to 2"Schedule 40 Pipe Longitudinal 8 LW, 10,40 1320 1870 2290 2550 1"to 2"Schedule 40 Pipe Lateral or Longitudinal 2,2 1/2,3,3 1/2,4,5,6,8 LW, 10,40 900 1280 1570 1750 1/4 Structural Steel k Lateral or Longitudinal 2,2 1/2,3,3 1/2,4,5,6,8 LW, 10,40 1070 1440 1740 1940 1001&1201 Strut NOTE:LW above refers to FM Approved Lightwall pipe,commonly referred to as Schedule 7.These ratings may also be applied to EN10220 and GB/T 8163 pipe. Schedule 10 above may be applied to GB/T 3091,GB/T 3092,EN 10255 M and H,JIS G3452.Schedule 40 above may be applied to GB/T3091,EN10255H or JISG3454 brace pipe. Strut Max.Horizontal Load lbs.)90°From Vertical Fig.# r 1/r= 100 200 300 1001 0.580 58" 4670 116" 1165 174" 518 1201 0.297 29" 3260 59" 785 89" 345 NOTE:Use NFPA13 table"Allowable Horizontal Load on Brace Assemblies Based on the Weakest Component of the Brace Assembly"reduction factors for maximum loads at varying angles. Refer to www.phd-mfg.com regarding further strut channel details The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut&Accessories • Pipe Clamps • Beam Clamps • Shields I STRUCTURE ATTACHMENT FITTINGS 041Hti FUNCTION: Sway brace adapter used to attach a PHD Manufacturing sway brace assembly to a steel bar joist or structural member of 3/8"maximum Fig. 035 thickness.To provide a point of connection when drilling or welding is not allowed or not practical. Sway brace assemblies are intended to be SWAY BRACE BAR installed in accordance with NFPA 13 and the manufacturer's installation instructions. JOIST ADAPTER SIZE: Braces up to 8"Pipe MAX Attaches to 3/8"thick MAX structural members When attaching to a structure thicker than 3/8",please see PHD Manufacturing Fig.045. C " FINISH: Electro-galvanized r MATERIAL: Ductile Iron -. INSTALL: Steel bar joist manufacturer's warranty requires attachment within 6"of chord panel point. Place on structural member with the flange contacting the back of the jaw.Tighten set screws finger tight,then evenly tighten until hex heads break off. Attached PHD structural attachment to Fig. c Ops 035 with the supplied attachment bolt,ensuring that the attachment bolt head bottoms out securely. Please note that the maximum load will be limited by the PHD Manufacturing structural attachment utilized with this adapter. APPROVALS: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with NFPA fastener tables and PHD sway brace components only ORDERING: Specify figure number UL Maximum Design Load Weight Ea. Pipe Size lbs. j kN lbs. kq 8"MAX (200) 2015 (8.96) 2-38 (1-08) '.. FM Maximum Design_Load Beam Brace Angle X-Z Y-Z Beam Brace Angle A-B Flange From Vertical Flange From Vertical Thickness (Degrees) lbs. kN lbs. kN Thickness (Degrees) _ lbs. kN 30°-44° 1040 (462) 970 (4.31) 30°-44' 1150 (5.11) 3/8"Max 45°-59° 1490 (6.62) 1370 (6.09) 3/8'Max 45°-59° 1660 (7.38) 60°-74° 1800 (8.00) 2080 (9.16) 60°-74° 1990 (8.85) 75°-90° 2010 (8.94) 2300 (10.23) 75°-90° 2220 (9.87) •"MAX. X 414A, *16,41, Unless otherwise specified,all dimensions en drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. 44018 Columbiana-Waterford Road " Columbiana, Ohio 44408-9481 Phone: 800-321-2736 • 330-482-9256 (� c) Fax: 330-482-2763 Web: www.phd-mfg.com FIG. 035 SWAY BRACE BAR JOIST ADAPTER Pipe Braced: 8" Pipe MAX Function: Sway brace adapter used to attach a PHD Manufacturing sway brace assembly to a steel bar joist or structural member of 3/8" maximum thickness. To provide a point of connection when drilling or welding is not allowed or not practical. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with NFPA fastener tables and PHD sway brace components only Material: Ductile Iron Installation: Steel bar joist manufacturer's warranty requires attachment within 6"of chord panel point. Place on structural member with the flange contacting the back of the jaw. Tighten set screws finger tight, then evenly tighten until hex heads break off. Attach PHD structural attachment to Fig. 035 with the supplied attachment bolt, ensuring that the attachment bolt head bottoms out securely. Please note that the maximum load will be limited by the PHD Manufacturing structural attachment utilized with this adapter. UL Maximum Design Load Pipe Size lbs. 8" MAX 2015 FM Maximum Design Load Brace Angle X-Z Y-Z Brace Angle A-B Beam Flange From Vertical Beam Flange From Vertical Thickness _ (Degrees) lbs. lbs. Thickness (Degrees) lbs. 300-440 1040 970 30°-44° 1150 45°-59° 1490 1370 45°-59° 1660 3/8" Max 60°-74° 1800 2060 3/8„ Max 60°-74° 1990 750-900 2010 2300 75°-90° 2220 `->A MAX. '”.` ,ti ,mil z 1 The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut& Accessories • Pipe Clamps • Beam Clamps • Shields STRUCTURE ATTACHMENT FITTINGS At Q.I.di FUNCTION: Sway brace adapter used to attach a PHD Manufacturing sway brace assembly to a steel structural member of 3/8"minimum and 1 1/4" Fig. 045 maximum thickness.To provide a point of connection when drilling or welding is not allowed or not practical. Sway brace assemblies are S WAY BRACE intended to be installed in accordance with NFPA 13 and the STRUCTURAL manufacturer's installation instructions. SIZ& Braces up to 8"Pipe MAX ADAPTER Attaches to 3/8"MINIMUM and 1 1/4"MAX thick structural members When attaching to a structure less than 3/8"thick,please see PHD Manufacturing Fig.035. .7f1 FINISH: Electro-galvanized ..r MATERIAL: Ductile Iron saw INSTALL: Place on structural member with the flange contacting the back of the jaw.Tighten set screws finger tight,then evenly tighten until hex heads break off. Attached PHD structural attachment to Fig.045 with the / --,` supplied attachment bolt,ensuring that the attachment bolt head bottoms } out securely. Please note that the maximum load will be limited by the PHD Manufacturing structural attachment utilized with this adapter. X APPROVALS: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with NFPA fastener tables and PHD sway brace t/ c 1k us components only ORDERING: Specify figure number UL Maximum Desk n Load Weight Ea. Pipe Size_ lbs. kN lbs. kg 8"MAX (200) 2015 (8.96) 3.10 (1.41) FM Maximum Design Load Brace Angle X Y Beam Flange From Vertical Thickness (Degrees) lbs. kN lbs. kN 30°-44° 1150 (5.11) 900 (4.00) 3/8"Min. 45°-59° 1800 (8.00) 1050 (4.67) 1 1/4"Max. 60°-74° 2230 (9.91) 1260 (5.60) 75°-90° 2460 (10.94) 1410 (6.27) Unless otherwise specified.all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. PHD Manufacturing, Inc. 44018 Columbiana-Waterford Road Columbiana, Ohio 44408-9481 Phone: 800-321-2736 . 330-482-9256 ,�) 1 CAA Fax: 330-482-2763 Web: www.phd-mfg.com FIG. 045 SWAY BRACE STRUCTURAL ADAPTER Pipe Braced: 8" Pipe MAX Function: Sway brace adapter used to attach a PHD Manufacturing sway brace assembly to a steel structural member of 3/8"minimum and 1 1/4" maximum thickness. To provide a point of connection when drilling or welding is not allowed or not practical. Sway brace assemblies are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. Approvals: Underwriters Laboratories listed for US and Canada Factory Mutual approved Listed for use with NFPA fastener tables and PHD sway brace components only Material: Ductile Iron Installation: Place on structural member with the flange contacting the back of the jaw. Tighten set screws finger tight, then evenly tighten until hex heads break off. Attach PHD structural attachment to Fig. 045 with the supplied attachment bolt, ensuring that the attachment bolt head bottoms out securely. Please note that the maximum load will be limited by the PHD Manufacturing structural attachment utilized with this adapter. UL Maximum Design Load Pipe Size lbs. 8" MAX 2015 FM Maximum Design Load Brace Angle X Y Beam Flange From Vertical Thickness (Degrees) lbs. lbs. 300-44° 1150 900 3/8" Min. 45 0-590 1800 1050 1 1/4" Max. 60°-74° 2230 1260 75°-90° 2460 1410 ,x ____ - y X The Complete Line of Pipe Supports and Devices Pipe Hangers • Strut& Accessories • Pipe Clamps • Beam Clamps • Shields SWAY BRACE FITTINGS 1 d FUNCTION: Designed for bracing pipe against sway and seismic disturbances. Intended to function as a 4-way sway brace assembly component for use Fig. 054 on risers and other vertical piping configurations,each brace pipe must be used in conjunction with a PHD Manufacturing pipe attachment. Fig. THREADLESS SWAY 054 can also function as a longitudinal brace connection when attached to BRACE FITTING a lateral brace assembly using PHD Manufacturing sway brace fittings where building codes permit. The brace attachment component of a ir sway brace system used in conjunction with PHD Manufacturing "� KJ �� \ structural attachment fittings,and joining together two bracing pipe j elements forms a complete sway brace assembly. Sway brace assemblies V' b )I' are intended to be installed in accordance with NFPA 13 and the manufacturer's installation instructions. ` ,y; SIZE: Pipe size 1"thru 4"Schedule 10 thru 40 IP. f r N Can use 1"or 1 14"Schedule 40 IP as sway bracing elements. t -. 1 FINISH: Electro-galvanized MATERIAL: Low Carbon Steel INSTALL: Insert bracing pipe into fitting against the pivot bolt and tighten each fitting set screw finger tight. Then tighten each set screw evenly until hex head breaks off. Fitting can pivot for adjustment to proper brace angle, then tighten pivot bolt. Bracing connection must be positioned as close as possible to the braced pipe and cannot be more than 3"away. APPROVALS: Underwriters Laboratories listed for US and Canada,Subject 203A Issue Number 1,May 21,1999 Listed for use with NFPA and PHD sway brace components only ORDERING: Specify figure number and brace pipe size X brace pipe size UL Maximum Design Loads Brace Pipe Wei.ht Ea. Combinations lbs.; kN lbs. kg 1X 1 (25)X(25) 655 (2.91) 1.90 (0.86) 1 X 1 1/4 (25)X(32) 655 (2.91) 1.82 (0.83) 1 1/4 X 1 1/4 (32)X(32) 655 (2.91) 1.74 (0.79) Unless otherwise specified,all dimensions on drawings and in charts are in inches and dimensions shown in parentheses are in millimeters. PHD Manufacturing, Inc. 1