HomeMy WebLinkAboutBLD2018-00042 - 03 ENERGY WORKSHEETSi Size:State o
lnformation Contact lnformation
Design Temperature Difference (AT)
\T = lndoor (70 degoes) - Outdoor Destgn Temp
Heating Svstem Tvpe: OAll other svstems OHeat Pump
To see detailed instructions for each section, place your cursor on the word "lnstructions".
Desiqn Temperature
lnstructions
Area of Buildinq
Conditioned Floor Area
lnstructions Conditioned Floor Area (sq ft)
Average Ceiling Height
lnstructrons Average Ceiling Height (ft)
Glazinq and Doors
I nstructions
Skvliqhts
lnstructions
lnsulation
Attic
lnstructions
Single Rafter or Joist Vaulted
lnstructions
Above Grade Walls 1)
U-Factor X
0.250
U-Factor X
0.50
U-Factor X
0.026
U-Factor X
0.020
U-Factor X
0.032
U-Factor X
0.029
U-Factor X
No selection
F-Factor X
0.303
F-Factor X
Conditioned Volume
13.824
Area = UA
| 1,728 | 432 0o
Area = UA
Area =UA
44.93
UA
34.56
UA
55.30
UA
50.11
:1
::
UA
45
616.90
27,760 Btu / Hour
6,718 Btu / Hour
34,479 Btu / Hour
lnstructions
Floors
lnstructions
Below Grade Walls
lnstructions
Slab Below Grade
lnstructions
Slab on Grade
lnstructions
Location of Ducts
I nstructions
Fioure 1.
a-1i:s-]
f-iils-]
Area
Area
Area
Length
Length
Duct Leakage Coefficient
1.10
Sum of UA
Envelope Heat Load
Sum of UA X \T
Air Leakage Heat Load
VolureX O6XiTX 018
Building Design Heat Load
Nr Leakage + Envelope Heat Loss
Building and Duct Heat Load 37,927 Btu I Hour
Ducts in un@nditioned spa@: Sum of Building Heat Loss X 1.10
Ducts in @ndiloned spa@: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 47,408 Btu / Hour
Building and Duct Heat Loss X 1.40 for Fq@d Air Furna@
Building and Duct Heal Loss X 1.25 for Heat Pump
,4
fi lt allout theof boxesand atethat a to As makedrop-downs pplicable your project.yougreen
valuessome bewill forcalculated tf do seenot selectionthe need thein EnSUyouyouyouoptions,drop-down please
at 956-2042 assistance.forProgram(360
loads.
Please
Port Townsend
u 0.25
R49
R 49 Advanced
R 21 INT plus R 12 ci
R30
No Slab Below G.ade in this project.t
No Slab on Grade in this project.?
Unconditioned Space
(07/01/13)
1,728
1.728
8.0
Areal-lizs-]
w
Parcell # 965000113
Solheim
t
Select R value Y
I o
Window, Skylight and Door Schedule
Project lnformation
Parcell #965000113
Solheim
Contact lnformation
Lexar Homes
Rob Owens
Exempt Swinging Door (24 sq. ft. max.)
Exempt Glazed Fenestration (15 sq. ft. max.)
Vertical Fenestration (Windows and doors)
Component
Description
Ref. U-factor
Ref. U-factor
Width Height
et. Feet In'h Feetln"h
Width Height
Qt. Feet In"h Feetlnth
Area UA
0.0 0.00
0.0 0.00
Area UA
14.0 3.78
20.0 5.40
24.0 6.48
100.0 27.00
60.0 16.20
70.0 18.90
42.0 11.34
40.0 10.80
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0,00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
4036 0.27
5040 0.27
8030 0.27
5050 0.27
6050 0.27
7050 0.27
7030 0.27
5040 0.27
3.514
1 5 4
1 8 3
5 54
2 6 5
2 7 5
2 7 3
2 5 4
II
oo
Sum of Vertical Fenestration Area and UA
Vertical Fenestration Area Weighted U = UNArea
Width Height
Qt. Feet Inth Feet In"h
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
370.0 99.90
0.27
Area UA
o ol o.oo
0.00
370.0 99.90
Overhead Glazing (Skylights)
Component
Ref. U-factor
Sum of Overhead Glazing Area and UA
Overhead Glazing Area Weighted U = UNArea
Total Sum of Fenestration Area and UA (for heating sysfem sizing calculations)
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00