Loading...
HomeMy WebLinkAboutSEP2017-00107 6(Ato M".1 C!o f lo, N Monitoring Inspection Site Plan Update ;/� Include the following Items on the site plan Case# -c/cg l > Property boundaries > Drainfield area if known Parcel# (2 "2 / 'C C 8" > Names of adjacent streets > Septic tanks and/or Pump chamber Address 7/ /74 r.,,,,:,,,,/- // 9 Driveways and parking areas > Wells w/distance to OSS components Prepared by ) 97-e--/Lei > Surface water(ponds,creeks,etc) > Buildings-residence,sheds,garages,etc Date Prepared !f. `6, I • North Arrow C 0 L, r,,, r t ,,,, ✓I T ,. 'r-, , - ki \ 4 %NI:* tf°' 40 _ Vis, ,,;d (2rv:wTC4C SUA it 4 r _Flopt . Plot plan submitted b N. VL, as a part of a Monitoring inspe ion fiC a c G► Not reviewed or approved by JCPH. 611201"1 Goodman,Inc. 2495 Cape George Rd 5 7155 Port Townsend, WA 98368 PROPERTY INFORMATION Location:791 Fairmount Rd Port Townsend , Mail To: Current Resident 6, Tax ID:902241008 ' 9� 4 ^"' E !� �64 , 791 Fairmount Rd Use:Residential,Single Family ?,+',"'C3 Port Townsend,WA — 0 - GENERAL SYSTEM TYPE:Gravity ON ID:SOM16-01081 Fold ' ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold Here Here Inspected:06/06/2017 - Inspection Type:ROUTINE - Correction Status:Some Corrections Made Company: Certification-Level 1 Work Performed By: Submitted 06/07/2017 by: Goodman, Inc. Doug Nebel Doug Nebel This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development. COMMENTS&GENERAL INSPECTION NOTES Deficiencies Noted:deficiencies must be corrected to ensure proper longevity of the Onsite Sewage System. Septic tank is two tanks with cross over pipe,250 gal.each.D-box has riser to ground level,water tight.No permit on file,size and adequacy of drain field is unknown.new site drawing sent to H.D. GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected All Components accessible for maintenance,secure and in good condition: YES Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: YES Improper encroachment(roads,buildings,etc.)onto component(s): NO Component settling problems observed: NO Abnormal ponding present for one or more of the disposal components: NO Subsurface components adequately covered YES Owner compliance issues noted NO Site maintenance required(e.g.Landscape maintenance)If yes,describe in comments: NO Occupant compliance problem(occupant not operating the system properly). If YES,describe in notes: NO If deficiencies were identified on last inspection were they corrected before or during this inspection? N/A (If NO,describe in notes,NA=no deficiencies on last report): OSS Components,structures and appurtenances located per as-built/record drawing(reference Septic NO-See Comments Permit#in notes). If NO,describe in notes and if no as-built exists or changes made,state NO and provide record to Health Dept: Alterations made to the OSS(valves adjusted,timer settings modified,ports installed,etc.)(If YES, NO describe in notes): The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. NO Is the SEP case in a finaled/completed status?(if NO explain in comments) NO-See Comments ONSITE SEWAGE SYSTEM INSPECTION DETAIL TANK:Septic Tank-2 Compartment This component was: Fully Inspected Component appears to be functioning as intended: YES Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Effluent Filter Cleaned(N/A=Not Present): N/A Effluent filter/screen needed cleaning on arrival N/A Compartment 1 Scum accumulation(Inches,if other specify): 1 Compartment 1 Sludge accumulation(Inches,if other specify): 4 Compartment 2 Scum accumulation(Inches,if other specify): 0 Compartment 2 Sludge accumulation(Inches,if other specify): 0 Pumping needed: NO Approximate Gallons to be pumped(if needed)by Certified Pumper: 500 ReportiD:598695 View inspection reports online at www.onlinerme.com Page 1 of 2 •istribution:D-Box This component was: Fully Inspected D-Box in good condition: YES D-Box outlets set to allow equal effluent distribution: YES •rainfield(disposal):Gravity This component was: Fully Inspected Component appears to be functioning as intended: YES Ponding present?If YES explain in comments: NO • n I, c?, dc, This report indicates certain characteristics of the onsite sewage system at the time of visit.In no way is this report a guarantee of operation or future performance. ReportID:598695 View inspection reports online at www.onlinerme.com Page 2 of 2 Jefferson County Assessor & Treasurer- Property Details - 43 GREGORY & TIFFANY ... Page 1 of 3 Jefferson County Assessor & Treasurer 22743 GREGORY & TIFFANY BENTON for Year 2016 - 2017 Property Account Property ID: 22743 Legal Description: S24 T29 R2W TAX 9 &IL TAX L TAX RR-9 Parcel Number: 902241008 Agent Code: Type: Real Tax Area: 0151- 1-50F5E5H2L1 Land Use Code 11 Open Space: N DFL N Historic Property: N Remodel Property: N Multi-Family Redevelopment: N Township: 29N Section: 24 Range: 2W Location Address: 791 FAIRMOUNT RD Mapsco: PORT TOWNSEND,WA 98368 Neighborhood: S24 T29 R2W& LUNDSTROM Map ID: Neighborhood CD: 5460 Owner Name: GREGORY&TIFFANY BENTON Owner ID: 90345 Mailing Address: 791 FAIRMOUNT RD %Ownership: 100.0000000000% PORT TOWNSEND,WA 98368-9347 Exemptions: Pay Tax Due Select the appropriate checkbox next to the year to be paid.Multiple years may be selected. Year-Statement ID Tax Assessment Penalty Interest Total Due 2017- 12463 (Balance) $1196.17 $20.85 $0.00 $0.00 $1217.02 Total Amount to Pay:$ *Convenience Fee not included Taxes and Assessment Details Property Tax Information as of 06/20/2017 NOTE:If you plan to submit payment on a future date, Amount Due if Paid on: 7. make sure you enter the date and click RECALCULATE to obtain the correct total amount due. http://trueweb.jeffcowa.us/propertyaccess/Property.aspx?cid=0&year=2016&prop_id=22743 6/20/2017 Jefferson County Assessor& Treasurer - Property Details - 43 GREGORY & TIFFANY ... Page 2 of 3 Click on"Statement Details"to expand or collapse a tax statement. Statement First Half Second Base Amount YearID Base Half Penalty Interest Paid Due Amt. Base Amt. R Statement Details 2017 12463 $1217.64 $1217.02 $0.00 $0.00 $1217.64 $1217.02 R Statement Details 2016 12514 $1113.87 $1113.26 $0.00 $0.00 $2227.13 $0.00 Values Taxing Jurisdiction Improvement / Building Improvement#1: Residential Bldg State Code: 11 1520.0 sqft Value: $74,157 Exterior Wall: SI/ST Floor Construction: FRAME Foundation: CONBL Heating/Cooling: ELBB Roof Cover: METAL Type Description Class Sub Year Area CD Class CD Built MA Main Area 3- 15SF 1935 1008.0 MA2 Second Floor Main Area 3- 15SF 1935 512.0 HDECK House Deck 3 * 1935 452.0 OTHER Other * * 1935 0.0 Sketch Property Image This property contains TIFF images. Click on the button(s)to download the full image (which may contain multiple pages). yy-.,4x ^A0= • 44414 4 y y http://trueweb.jeffcowa.us/propertyaccess/Property.aspx?cid=0&year=2016&prop_id=22743 6/20/2017 Jefferson County Assessor& Treasurer - Property Details - 43 GREGORY & TIFFANY ... Page 3 of 3 re ear- • vSe-cot- vi n.. 4 �1 A35Q... w.a.v.a4n.m.nanar .� =7. Ss:ac3- -- wRFX!(310e1:]h Land Roll Value History Deed and Sales History Payout Agreement io This website is under active development. Some functionality is not yet available and data is not guaranteed. Assessor Home Page Treasurer Home Page County Maps Permits Disclaimer Website version:9.0.40.29 Database last updat�eld on:6/20/2017 3:47 © N.Harris Computer Corporation http://trueweb.jeffcowa.us/propertyaccess/Property.aspx?cid=0&year=2016&prop_id=22743 6/20/2017