HomeMy WebLinkAboutBLD2021-00274-14 SEPGoodman, Inc. 360-385-71552495 Cape George Rd Port Townsend, WA 98368 Tax ID: 601103009 Location:LEONA DR Use: Mail To:ROBERT NUERENBERG 3169 DAY RD GREENBANK, WA 982539728 ON ID: SOM1999-00136 PROPERTY INFORMATION Fold Here Fold Here ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Inspected: 05/01/2020 - Inspection Type: PROPERTY SALE - Correction Status: No corrections made This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development. Submitted 05/01/2020 by: Doug Nebel Work Performed By: Doug Nebel Company:Certification - Level 1 Goodman, Inc. COMMENTS & GENERAL INSPECTION NOTES Deficiencies Noted: deficiencies must be corrected to ensure proper longevity of the Onsite Sewage System. There is no house on property, tank has never been connected to anything. Water level in tank is 6" at bottom, clear water in tank. D box has a valve box over it as a riser, not sealed at the bottom and not water tight. Inspection ports in drainfield are dry. Vacant property, assessment of drainfield was not possible. The General Site and System Conditions were:Fully Inspected All Components accessible for maintenance, secure and in good condition:YES Surfacing effluent from any component (including mound seepage):NO Components appear to be watertight - no visual leaks:YES Improper encroachment (roads, buildings, etc.) onto component(s):NO Component settling problems observed:NO Abnormal ponding present for one or more of the disposal components:NO Subsurface components adequately covered YES Owner compliance issues noted NO Site maintenance required (e.g. Landscape maintenance) If yes, describe in comments:NO Occupant compliance problem (occupant not operating the system properly). If YES, describe in notes:NO If deficiencies were identified on last inspection were they corrected before or during this inspection? (If NO, describe in notes, NA = no deficiencies on last report): N/A OSS Components, structures and appurtenances located per as-built/record drawing (reference Septic Permit # in notes). If NO, describe in notes and if no as-built exists or changes made, state NO and provide record to Health Dept: YES Alterations made to the OSS (valves adjusted, timer settings modified, ports installed, etc.) (If YES, describe in notes): NO The house/structure was vacant or used infrequently, assessment of the drainfield was not possible.YES Is the SEP case in a finaled/completed status? (if NO explain in comments)YES GENERAL SITE & SYSTEM CONDITIONS ONSITE SEWAGE SYSTEM INSPECTION DETAIL TANK: Septic Tank - 2 Compartment This component was: Fully Inspected Component appears to be functioning as intended:YES Effluent level within operational limits (if NO explain in comments):DeficientNO All required baffles in place (N/A = No baffles required):YES Effluent Filter Cleaned (N/A = Not Present):NO Compartment 1 Scum accumulation (Inches, if other specify):0 Effluent filter/screen needed cleaning on arrival NO Compartment 1 Sludge accumulation (Inches, if other specify):0 Compartment 2 Scum accumulation (Inches, if other specify):0 Compartment 2 Sludge accumulation (Inches, if other specify):0 Pumping needed:NO View inspection reports online at www .onlinerme.com Page 1 of 2ReportID: 856304 Approximate Gallons to be pumped (if needed) by Certified Pumper:1000 Drainfield (disposal): Gravity This component was: Fully Inspected Component appears to be functioning as intended:YES Ponding present? If YES explain in comments:NO Drainfield was vacuumed, flushed or hydro-jetted? (If YES, explain in comments)NO Distribution: D-Box This component was: Fully Inspected D-Box in good condition:YES D-Box outlets set to allow equal effluent distribution:YES This report indicates certain characteristics of the onsite sewage system at the time of visit. In no way is this report a guarantee of operation or future performance. View inspection reports online at www .onlinerme.com Page 2 of 2ReportID: 856304