Loading...
HomeMy WebLinkAboutSEP2019-00049 - 02 PERMIT/D-.&)M Public Heollh JEFFERSON COUNTY ENVIRONMENTAL PUBLIC HEALTH 615 Sheridan St. Port Townsend, WA 98368 wrnu. jeffe rsoncou ntypu bl i chea lth. org Phone 360-385-9444 Fax 360-379-4487 PERMIT #: SITE ADDRESS ON.SITE SEWAGE DISPOSAL PERMIT SEp19-00049 Date Received: 03/06/19 CAM' TALBOT RD Date lssued. 06/19/19 Date Expires: 06119122 APPLICANT:RICHARD & FOX 19009 148TH AVE SE RENTON WA 98058-9304 LEGAL DESCRIPTION: SNOW CREEK RANCH LOT 37 (REVISED) PARCEL #:995400036 PHONE: 206-271-2435 Section: 11 Township: 28N Ranqe: 2W DESIGNER NATHAN CLEAVER NATHAN CLEAVER SEPTIC DESIGN 262 NW THOMPSON RD POULSBO WA 98370 PHoNE: 360-598-6546 SYSTEM DESCRIPTION No. of Gallons per Day: CONVENTIONAL TRENCH 360 Type of work:NEW Drainfie -----Trench ------Septic Tan k----- Size: 1,250 gallonsLength: 200 feet Width: 3 feet Depth: 12 inches DISCLAIMER- This approval is for an on-site sewage system that meets the state and county standards in effect on the date of application. This approval for an on-site sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. All construction and development activities must comply with all permit conditions, state and local codes, and Recommended Standards and Guidance documents in effect when the permit is issued. The property owner is responsible for the accurate location of all property lines. Any removal of or major disturbance of soil in the primary or reserve drainfield area may create site conditions that are unacceptable for the installation of a sewage disposal system. Any change in drainfield or tank location may invalidate this permit unless prior approval is obtained from the Jefferson County Environmental Health Division. lf during excavation or development of the site an area of potential archeological significance is uncovered, all activity in the immediate area shall be halted, and the UDC Administrator shall be notified at once. Permit issued to CONSTRUCT, ALTER, REPAIR OR MODIFYAN INDIVIDUAL SEWAGE DISPOSAL SYSTEM IN JEFFERSON COUNTY, WASHINGTON This permit is issued for a period of three years (unless otherwise stated above) in accordance with Jefferson County Rules and Regulations for On This permit may not be renewed. e codified in JCC 8.15 as amended (A '1, { Jefferson County Environmental Health Specialist This permit with conditions must be onsite during all phases of construction HEALTH DEPARTMENT MUST BE CONTACTED FOR FINAL INSPECTION. SPECIAL CONDITIONS APPLY . SEE REVERSE & ADDITIONAL PAGES CONDITIONS OF APPROVAL - PERMIT NO.: SEP19-00049 1.) Approval/issuance of a sewage disposal permit or installation of a septic system does not guarantee the approval of other development or a building permit on this site. Future buildings that require connection to an on-site sewage system (OSS) shall only be approved if the OSS meets the current standards and codes in effect at the time of the building application. 2.) H - AS pER WAC 246-272AAND JEFFERSON COUNTY CODE 8.15 ALL ONSTTE SEWAGE SYSTEMS REQUIRE THATA RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272AAND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. 3.) 4.) 5.) 6.) A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINALAPPROVAL OF THE SEWAGE DISPOSAL PERMIT Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS. Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start. H - An asbuilt drawing and certification of completion by the Designer is required prior to final approval. Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system. Approval of this permit does not assure the existing septic system has capacity for all uses allowed by current code. 10' separation required between a Water line and all portions of the onsite sewage system; effluent transport line, tanks, treatment and disposal components. All components of the septic system are to be completely protected from vehicular traffic or mechanical disturbance. Drainlines are to be installed along the natural contours. Any portion of transport line under a driven way is to be sleeved/cased or equivalent. Risers are required to grade with secured lids over both compartments and over the outlet of the septic tank for inspection and maintenance/monitoring. Minimum 20" riser over inlet. Distribution boxes shall be fitted with a riser to grade, constructed of durable materials and a secured lid, adequately sized to allow visible inspection of the liquid level in the box. H - This permit is granted based on the recorded RESTRICTIVE COVENANT combining lots 35, 37, 39 of Snow Creek Ranch to meet the minimum land area required under WAC 246-2724 Onsite Sewage Code. COVENANT recorded AFN622680. Jefferson County Department of Community Development reviewed the application and the county GIS mapping system for the presence of critical areas and concluded that the property DOES NOT contain critical areas. However, future proposals will be subject to a new critical area review and conditions may be added if critical areas are found on the property. 7.) 8.) e.) 10) 11 .) 12) 13.) 14) 1s) sEP19-00049 \\tidemark\data\forms\F_SEP_Perm itmod. rpt Page 2 ol 2 6t19t2019