HomeMy WebLinkAboutBLD2020-00535 - 07 Engineering24
'
2'
4'
4'
4'
4'
4'
2'
4'12' 8" 4X8 BEAM
15" SQ X12"
CONC FOOTING
SEE POST DETAIL
3"
10' 4X8 BEAM 10' 61
4" 4X8 BEAM
10'
8' 4X8 BEAM15' 61
4" 4X8 BEAM
8' 4X8 BEAM 15' 61
4" 4X8 BEAM
10' 4X8 BEAM 10' 61
4" 4X8 BEAM
12' 8" 4X8 BEAM
3'-91
4"
CENTERLINE
FRAME TO 23' 11" DIA. FOR
HARDWARE CLEARANCE.
CUT 2X6 T&G CEDAR
DECKING TO 24 FOOT DIA.
Ø
2
3
'
-
1
1
"
SEE
FRAMING
DETAIL
RIM JOIST
SEE ELEVATION
SHT 2
KN
E
E
B
R
A
C
E
B
KN
E
E
B
R
A
C
E
B
KN
E
E
B
R
A
C
E
C
KN
E
E
B
R
A
C
E
C
KNEE BRACE A
UNDER
KNEE BRACE A
UNDER
4X8 BEAM
PC 444X4 POST
PB 44
12"
6"
15" SQ
COMPACTED MINERAL
SOIL (NO ORGANICS)
4 - #4X12"
REBAR
4X8
BEAM
2X8
RIM JOIST
TOENAIL AS
REQUIRED
HRS 12
W/ 14-10d NAILS
PLATFORM FRAMING PLAN
P
r
e
p
a
r
e
d
f
o
r
:
N
I
C
H
A
L
A
S
&
K
R
I
S
T
Y
P
A
P
A
D
O
P
U
L
O
S
16
7
H
A
Y
E
S
S
T
.
SE
A
T
T
L
E
,
W
A
9
8
1
0
9
24
'
P
L
A
T
F
O
R
M
F
R
A
M
I
N
G
P
L
A
N
PA
R
C
E
L
N
O
.
9
2
1
3
2
4
0
1
5
POST DETAIL
FRAMING DETAIL
123'367'
63'
103'
20% SLOPE
6'±
6" MIN
15% SLOPE
5'±
6" MIN
24'
10'
ENTRY DECK
STAIRS
SEE ENTRY
DECK DETAIL
4X8
4X8
4X8
2X8
2X8
2X8
2X8
4X4 POST
W/ EPC 44
& PC 44
4X8 BEAM
PC 44
15" SQ
18"
4X4 POST
ENTRY DECK
3
8" EXTERIOR
PLY DRIP EDGE MAIN PLATFORM
2x8 RIM JOIST
4X8 BEAM
HUC 48
PB 44
COMPACTED MINERAL
SOIL (NO ORGANICS)
4 - #4X12"
REBAR
24
'
P
L
A
T
F
O
R
M
E
L
E
V
A
T
I
O
N
PA
R
C
E
L
N
O
.
9
2
1
3
2
4
0
1
5
P
r
e
p
a
r
e
d
f
o
r
:
N
I
C
H
A
L
A
S
&
K
R
I
S
T
Y
P
A
P
A
D
O
P
U
L
O
S
16
7
H
A
Y
E
S
S
T
.
SE
A
T
T
L
E
,
W
A
9
8
1
0
9
PLATFORM
LOCATION
PLATFORM ELEVATION
OAK BAY ROAD
SITE LOCATION
OPTIONAL DECK
OPTIONAL DECK DETAIL
45.00
°
2' - 3'
4X8 BEAM
2-KBS1Z
(4 LOCATIONS)
4X4 KNEE BRACE
4X4 POST
2X6 DECK 2X6 DECK
2-KBS1Z ONE
LOCATION
AS
REQUIRED
4X8 BEAM
12"±
4X4
KNEE BRACE
2-A34
2X6 DECK
2-KBS1Z ONE
LOCATION
AS
REQUIRED
4X8 BEAM
12"±
4X4
KNEE BRACE
2-A34
VARIES 1/2" MIN
93
4"
2X6 T&G CEDAR
DECKING OR
11
8" PLYWOOD
2X8
RIM JOIST
1"
3
8" PLY
DRIP EDGE
ADD BLOCKING
AS NEEDED
STRUCTURAL NOTES:
1. Framing lumber, posts and beams shall be DF-L #1
2. Posts shall be preservative treated.
3. Galvanized nails are required with all preservative treated lumber.
4. All framing shall be fastened in accordance with 2016 IBC Table 2304.9.1.
5. Concrete shall have a minimum 28 day compressive strength of 2500 psi.
6. Reinforcing steel shall have a minimum yield strength of 40,000 psi.
7. All footings shall be placed on native undisturbed mineral soil.
8. Simpson connectors shall have ZMAX corrosion protection.
24
'
P
L
A
T
F
O
R
M
B
R
A
C
I
N
G
PA
R
C
E
L
N
O
.
9
2
1
3
2
4
0
1
5
P
r
e
p
a
r
e
d
f
o
r
:
N
I
C
H
A
L
A
S
&
K
R
I
S
T
Y
P
A
P
A
D
O
P
U
L
O
S
16
7
H
A
Y
E
S
S
T
.
SE
A
T
T
L
E
,
W
A
9
8
1
0
9
KNEE BRACE A DETAIL
KNEE BRACE B DETAIL
KNEE BRACE C DETAIL
DRIP EDGE DETAIL