HomeMy WebLinkAboutBLD2021-00005 - 06 FLOOR PLANW H COSD COSD 6 : 12 6 : 12 6 : 12 6 : 1 2 8 : 12 8 : 12 6 : 1 2 8 : 12 8 : 12 8 : 12 VENTILATION SCHEDULEVENTILATION SCHEDULE 2015 IRC TABLE M1507 2015 IRC TABLE M1507 MINIMUM REQUIRED LOCAL EXHAUST RATES FORMINIMUM REQUIRED LOCAL EXHAUST RATES FOR ONE- AND TWO-FAMILY DWELLINGSONE- AND TWO-FAMILY DWELLINGS AREA TO BE EXHAUSTEDAREA TO BE EXHAUSTED EXHAUST RATEEXHAUST RATE KITCHENS KITCHENS MIN 100 CFM @ 0.25" WG (IRC TABLE 1507.7)MIN 100 CFM @ 0.25" WG (IRC TABLE 1507.7) (RANGE HOOD OR DOWN DRAFT EXHAUST FAN RATED(RANGE HOOD OR DOWN DRAFT EXHAUST FAN RATED @ MIN 100 CFM @ 0.10" WG MAY BE USED TO EXHAUST FAN REQ)@ MIN 100 CFM @ 0.10" WG MAY BE USED TO EXHAUST FAN REQ) BATH, POWDER,BATH, POWDER,MIN 50 CFM @ 0.25" WG (IRC TABLE M1507.4)MIN 50 CFM @ 0.25" WG (IRC TABLE M1507.4) LAUNDRY ROOMSLAUNDRY ROOMS WHOLE HOUSE FANWHOLE HOUSE FAN SIZED PER "INTERMITTENT VENTILATION FLOW RATE" BELOW.SIZED PER "INTERMITTENT VENTILATION FLOW RATE" BELOW. *WHOLE HOUSE FANS LOCATED 4' OR LESS FROM INTERIOR GRILL*WHOLE HOUSE FANS LOCATED 4' OR LESS FROM INTERIOR GRILL TO HAVE A SONE RATING OF 1.0 OR LESS MEASURED @ 0.1" WGTO HAVE A SONE RATING OF 1.0 OR LESS MEASURED @ 0.1" WG ALL FANS TO VENT OUTSIDE. ALL OTHER REQUIREMENTS OF THE 2015 WSEC & THE 2015 IRCALL FANS TO VENT OUTSIDE. ALL OTHER REQUIREMENTS OF THE 2015 WSEC & THE 2015 IRC SECTION M1507 MUST BE MENTSECTION M1507 MUST BE MENT TO BE INSTALLED 2015 IRC SECTIONTO BE INSTALLED 2015 IRC SECTION TABLE M1507.3.1 THROUGH M1507.3.7TABLE M1507.3.1 THROUGH M1507.3.7 CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION CONTINUOUS WHOLE-HOUSE MECHANICAL VENTILATION SYSTEM AIRFLOW RATE REQUIREMENTSSYSTEM AIRFLOW RATE REQUIREMENTS DWELLING UNITDWELLING UNIT NUMBER OF BEDROOMSNUMBER OF BEDROOMS FLOOR AREAFLOOR AREA 0-10-1 2-32-3 4-54-5 6-76-7 77 (SQUARE FEET)(SQUARE FEET)AIRFLOW IN CFMAIRFLOW IN CFM - 1500- 1500 3030 4545 6060 7575 9090 1,501 - 3,0001,501 - 3,000 4545 6060 7575 9090 105105 3,001 - 4,5003,001 - 4,500 6060 7575 9090 105105 120120 4,501 - 6,0004,501 - 6,000 7575 9090 105105 120120 135135 6,001 - 7,5006,001 - 7,500 9090 105105 120120 135135 150150 7,500 +7,500 +105105 120120 135135 150150 165165 IRC TABLE M1507.3.3 (2)IRC TABLE M1507.3.3 (2) INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORS INTERMITTENT WHOLE-HOUSE MECHANICAL VENTILATION RATE FACTORS ABAB RUN TIME % IN EACHRUN TIME % IN EACH 25%25%33%33%50%50%66%66%75%75%100%100% 4-HR SEGMENT4-HR SEGMENT FACTORFACTOR 44 33 22 1.51.5 1.31.3 1.01.0 A.A.FOR VENTILATION SYSTEM RUN TIME VALUES BETWEEN THOSE GIVEN, THE FACTORS ARE PERMITTEDFOR VENTILATION SYSTEM RUN TIME VALUES BETWEEN THOSE GIVEN, THE FACTORS ARE PERMITTED B.B. TO BE DETERMINED BY INTERPOLATION. TO BE DETERMINED BY INTERPOLATION. C.C.EXTRA POLATION BEYOND THE TABLE IS PROHIBITEDEXTRA POLATION BEYOND THE TABLE IS PROHIBITED SDSD COCO SMOKE ALARMS:SMOKE ALARMS: * 110 V INTERCONNECTED W/ BATTERY BACKUP.* 110 V INTERCONNECTED W/ BATTERY BACKUP. * INSTALLED ON EACH FLOOR, IN EACH SLEEPING AREA,* INSTALLED ON EACH FLOOR, IN EACH SLEEPING AREA, AND OUTSIDE EACH SEPARATE SLEEPING AREA. INSTALLEDAND OUTSIDE EACH SEPARATE SLEEPING AREA. INSTALLED NOT LESS THAN 3' FROM THE DOOR OF A BATH WHICHNOT LESS THAN 3' FROM THE DOOR OF A BATH WHICH CONTAINS A TUB OR SHOWER UNLESS THIS PREVENTSCONTAINS A TUB OR SHOWER UNLESS THIS PREVENTS PLACEMENT IN A REQUIRED LOCATION.PLACEMENT IN A REQUIRED LOCATION. * LISTED IN ACCORDANCE WITH UL 217 AND TO COMPLY WITH NFPA72* LISTED IN ACCORDANCE WITH UL 217 AND TO COMPLY WITH NFPA72 COMBINATION SMOKE & CARBON MONOXIDE ALARMS:COMBINATION SMOKE & CARBON MONOXIDE ALARMS: * INSTALLED ON EACH FLOOR, OUTSIDE OF EACH SEPARATE* INSTALLED ON EACH FLOOR, OUTSIDE OF EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS,SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS, AND IN A BEDROOM THAT CONTAINS A GAS FIREPLACE IN THE BEDROOMAND IN A BEDROOM THAT CONTAINS A GAS FIREPLACE IN THE BEDROOM OR THE ADJACENT BATHROOM.OR THE ADJACENT BATHROOM. * SMOKE ALARM REQUIREMENTS PER ABV* SMOKE ALARM REQUIREMENTS PER ABV * COMBINATION SMOKE & CARBON MONOXIDE ALARMS LISTED IN* COMBINATION SMOKE & CARBON MONOXIDE ALARMS LISTED IN ACCORDANCE WITH UL 217 & UL 2034.ACCORDANCE WITH UL 217 & UL 2034. EN ER G Y COD EENERGY COD E EFFICIENT BUILDING ENVELOPE: 1a(0.5 credits)EFFICIENT BUILDING ENVELOPE: 1a(0.5 credits) PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS:PRESCRIPTIVE COMPLIANCE IS BASED ON TABLE R402.1.1 WITH THE FOLLOWING MODIFICATIONS: VERTICAL FENESTRATION U = 0.28VERTICAL FENESTRATION U = 0.28 FLOOR R-38FLOOR R-38 SLAB ON GRADE R-10 PERIMETER & UNDER ENTIRE SLABSLAB ON GRADE R-10 PERIMETER & UNDER ENTIRE SLAB BELOW GRADE SLAB R-10 PERIMETER & UNDER ENTIRE SLAB OR COMPLIANCE BASED ON SECTIONBELOW GRADE SLAB R-10 PERIMETER & UNDER ENTIRE SLAB OR COMPLIANCE BASED ON SECTION R402.1.4: REDUCE THE TOTAL UA BY 5%.R402.1.4: REDUCE THE TOTAL UA BY 5%. HIGH EFFICIENCY HVAC EQUIPMENT 3b:HIGH EFFICIENCY HVAC EQUIPMENT 3b: (1.0 CREDITS) (1.0 CREDITS) AIR - SOURCE HEAT PUMP WITH MINIMUM HSPF OF 9.0 BEING SELECTED AND SHALL SPECIFY THEAIR - SOURCE HEAT PUMP WITH MINIMUM HSPF OF 9.0 BEING SELECTED AND SHALL SPECIFY THE HEATING EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCYHEATING EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY EFFICIENT 5a:EFFICIENT 5a: (0.5 CREDIT) (0.5 CREDIT) ALL SHOWER - HEAD & KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL BE RATED @ 1.75 GPM OR LESS.ALL SHOWER - HEAD & KITCHEN SINK FAUCETS INSTALLED IN THE HOUSE SHALL BE RATED @ 1.75 GPM OR LESS. ALL OTHER LAVATORY FAUCETS SHALL BE RATED @ 1.0 GPM OR LESS. BEING SELECTED AND SHALL SPECIFYALL OTHER LAVATORY FAUCETS SHALL BE RATED @ 1.0 GPM OR LESS. BEING SELECTED AND SHALL SPECIFY THE HEATING EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCYTHE HEATING EQUIPMENT TYPE AND THE MINIMUM EQUIPMENT EFFICIENCY EFFICIENT WATER HEATING 5c:EFFICIENT WATER HEATING 5c: (1.5 CREDITS)(1.5 CREDITS) WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING:WATER HEATING SYSTEM SHALL INCLUDE ONE OF THE FOLLOWING: GAS,PROPANE OR OIL WATER HEATER WITH A MINIMUM EF OF 0.91GAS,PROPANE OR OIL WATER HEATER WITH A MINIMUM EF OF 0.91 OR SOLAR WATER HEATING SUPPLEMENTING A MINIMUM STANDARD WATER HEATER.OR SOLAR WATER HEATING SUPPLEMENTING A MINIMUM STANDARD WATER HEATER. SOLAR WATER HEATING WILL PROVIDE A RATED MINUMUM SAVINGS OF 85 THERMS OR 2000 kWh BASEDSOLAR WATER HEATING WILL PROVIDE A RATED MINUMUM SAVINGS OF 85 THERMS OR 2000 kWh BASED ON THE SOLAR RATING AND CERTIFICATION CORPORATION (SRCC) ANNUAL PERFORMANCE OG-300 CERTIFIEDON THE SOLAR RATING AND CERTIFICATION CORPORATION (SRCC) ANNUAL PERFORMANCE OG-300 CERTIFIED SOLAR WATER HEATING SYSTEM. OR ELECTRIC HEAT PUMP WATER HEATER WITH A MIN EF OF 2.0 AND MEETINGSOLAR WATER HEATING SYSTEM. OR ELECTRIC HEAT PUMP WATER HEATER WITH A MIN EF OF 2.0 AND MEETING THE STANDARDS OF NEEA'S NORTHERN CLIMATE SPECIFICATIONS FOR HEAT PUMP WATER HEATERS.THE STANDARDS OF NEEA'S NORTHERN CLIMATE SPECIFICATIONS FOR HEAT PUMP WATER HEATERS. TO QUALIFY TO CLAIM THIS CREDIT THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEINGTO QUALIFY TO CLAIM THIS CREDIT THE BUILDING PERMIT DRAWINGS SHALL SPECIFY THE OPTION BEING SELECTED AND SHALL SPECIFY THE WATER HEATER EQUIPMENT TYPE AND THE MINIMUM EFFICIENCY AND,SELECTED AND SHALL SPECIFY THE WATER HEATER EQUIPMENT TYPE AND THE MINIMUM EFFICIENCY AND, FOR SOLAR WATER HEATING SYSTEMS, THE CALCULATION OF THE MINIMUM ENERGY SAVINGS.FOR SOLAR WATER HEATING SYSTEMS, THE CALCULATION OF THE MINIMUM ENERGY SAVINGS. 4X44X4 CONCCONC PADPAD SD SD SD SD 16'-6"1'-10" 5'-8" 3'-0" 3'-9" 6 '-8 " 4 '-1 " 9 '-6 " 8 '-2 " 7'-6" 9 '-2 " 4 '-6 " 2 '-0 " 9 '-6 " 2 4 '-0 " 7 '-1 0 " 4 '-6 " 11'-6" 2 '-0 " 8 '-6 " 3'-6"10'-2" 4 '-6 " 4 '-8 " 7 '-8 " 2 '-4 " 3 '-6 " 10'-2"4'-4"3'-8"4'-0"4'-0"5'-8"4'-0"8'-2"5'-9" 3'-6"7'-8"4'-4" 1 '-0 " 1 '-0 " 1 9 '-0 " 5 '-0 " 5 '-4 " 1 8 '-6 " 2 '-6 " 8 '-0 " 2 '-0 " 7 8 '-0 " 3 '-1 0 " 2 '-8 " 9 '-2 " 5 '-0 " 7 '-0 " 2'-3" 6'-0"8'-0" 2'-3"7'-6" 23'-0"10'-9"12'-0"13'-9" 59'-6" 2 '-6 " 5 '-1 0 " 1 1 '-4 " 2 '-4 " 8 '-8 " 2 '-4 " 1 1 '-6 " 6 '-0 " 2 '-0 " 2 '-0 " 7'-1" 6'-6" 13'-6" 9'-0" 17'-6"7'-6"8'-0" 12'-6"18'-0"15'-6" 3'-6" 3 '-6 " 59'-6" 7 8 '-0 " 12" BUILT UP COL12" BUILT UP COL (FURNACE ABV)(FURNACE ABV) A/AA/A MIRCOMIRCO 5' TUB5' TUB GARAGEGARAGE M CLOSETM CLOSET M BATHM BATH M BEDROOMM BEDROOM 5X65X6 SHWRSHWR MUDBEDMUDBED DWDW BEDROOM 2BEDROOM 2 DD WW UTILITYUTILITY CLCL (2) 2660 SH(2) 2660 SH 5050 XO5050 XO TEMPTEMP 2660 SH2660 SH PORCHPORCH 2650 SH2650 SH CLCL 2650 SH2650 SH 8080 SGD8080 SGD 12' X 8' SGD12' X 8' SGD 6060 XO6060 XO 5050 XO5050 XO DININGDINING 5'5' T/ST/S BEDROOM 1BEDROOM 1 LINLIN BATHBATH 2040 SH2040 SH CLCL 6068 BP6068 BP 5050 XO5050 XO 36" R36" R 4X9 ISLAND4X9 ISLAND BB AA RR DENDEN CLCL PORCHPORCH VAULTEDVAULTED GREAT ROOM GREAT ROOMGASGAS FPFP VOSVOS BUILT INBUILT IN VAULTEDVAULTED KITCHENKITCHEN 1/2 BATH1/2 BATH 9' CLG9' CLG PATIOPATIO 9' CLG9' CLG 9' CLG9' CLG 16' X 8' OH GD16' X 8' OH GD 10' HOT TUB10' HOT TUB FLOOR PLAN FLOOR PLAN 2561 SQ FT LIVING2561 SQ FT LIVING 1/4" = 1' 1/4" = 1' 552 SQ FT GARAGE552 SQ FT GARAGE 298 SQ FT COVERED AREA298 SQ FT COVERED AREA 193 SQ FT PATIO193 SQ FT PATIO GG VAULTEDVAULTED ENTRYENTRY SS RANGE HOODSS RANGE HOOD CLCL CLCL 48" PANTRY48" PANTRY DBLDBL OVOV VAULTEDVAULTED 9' CLG9' CLG 30803080 30683068 SCSC 30683068 26682668 26682668 PDPD 28682868 26682668 BUILT INBUILT IN 2468246824682468 24682468 24682468 28682868 26682668 28682868 28682868 5'-4" DOOR/WINDOW5'-4" DOOR/WINDOW UNITUNIT 28682868 26682668 6068 BP6068 BP FANFAN VOSVOS HT LTHT LT FANFAN VOSVOS 100 CFM FAN VOS100 CFM FAN VOS WHOLE HOUSE FANWHOLE HOUSE FAN W/ AUTO TIMERW/ AUTO TIMER & MANUAL OVERIDE& MANUAL OVERIDE FANFAN VOSVOS FANFAN VOSVOS FANFAN VOSVOS TOTAL WINDOW AREA 351 SFTOTAL WINDOW AREA 351 SF TOTAL LIVINGTOTAL LIVING 2561 SF2561 SF GLAZING %GLAZING %14%14% A/6A/6 A/6A/6 RR FLUSHFLUSH 12" CONC STEP12" CONC STEP 12" BUILT UP COL12" BUILT UP COL 108"108" NOTE:NOTE: ALL EXTERIOR WINDOWS AND DOORS HUNGALL EXTERIOR WINDOWS AND DOORS HUNG AT 8' HIGH THIS FLOOR (UNO)AT 8' HIGH THIS FLOOR (UNO) NOTE:NOTE: 5/8" TYPE "X" GWB ON5/8" TYPE "X" GWB ON WARM WALLS, CEILINGWARM WALLS, CEILING AND POSTSAND POSTS PROVIDE 1 3/8" SOLID CORE DOORPROVIDE 1 3/8" SOLID CORE DOOR OR 20 MIN FIRE DOOR W/ RATEDOR 20 MIN FIRE DOOR W/ RATED METAL FRAME WITH SELF-CLOSERMETAL FRAME WITH SELF-CLOSER SAFETY/TEMPERED GLASSSAFETY/TEMPERED GLASS REQUIRED PER 2015 IRC SECTION R308.4 REQUIRED PER 2015 IRC SECTION R308.4 FACTORY BUILT FIREPLACE TO BE LISTED,FACTORY BUILT FIREPLACE TO BE LISTED, LABELED AND INSTALLED WITH THE CONDITIONLABELED AND INSTALLED WITH THE CONDITION OF THE LISTING. FACTORY BUILT FIREPLACE MUSTOF THE LISTING. FACTORY BUILT FIREPLACE MUST BE TESTED IN ACCORDANCE WITH UL127 & COMPLY BE TESTED IN ACCORDANCE WITH UL127 & COMPLY W/ THE PROVISIONS OF IRC R100.6.2W/ THE PROVISIONS OF IRC R100.6.2 EMERGENCY ESCAPE WINDOWS AND RESCUE OPENINGS:EMERGENCY ESCAPE WINDOWS AND RESCUE OPENINGS: MINIMUM OPENING AREA SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SFMINIMUM OPENING AREA SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.7 SF NET CLEAR HEIGHT SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL NOT BENET CLEAR HEIGHT SHALL BE NOT LESS THAN 24 INCHES AND THE NET CLEAR WIDTH SHALL NOT BE LESS THAN 20 INCHES.LESS THAN 20 INCHES. GRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THANGRADE FLOOR OR BELOW GRADE OPENINGS SHALL HAVE A NET CLEAR OPENING OF NOT LESS THAN 5.0 SF.5.0 SF. EMERGENCY ESCAPE AND RESCUE WINDOWS (EGRESS) MUST BE NO GREATER THAN 44 INCHESEMERGENCY ESCAPE AND RESCUE WINDOWS (EGRESS) MUST BE NO GREATER THAN 44 INCHES ABOVE FINISHED FLOOR TO THE BOTTOM OF THE WINDOW OPENING.ABOVE FINISHED FLOOR TO THE BOTTOM OF THE WINDOW OPENING. EGRESSEGRESS EGRESSEGRESS QTYQTY DESCRIPTIONDESCRIPTION SIZESIZE AREAAREA EXTERIOR WINDOW - DOOR SCHEDULEEXTERIOR WINDOW - DOOR SCHEDULE 11 11 11 22 11 11 22 11 22 11 22 M BEDM BED GRGR DININGDINING B1,B2B1,B2 BATHBATH GARAGEGARAGE DEN, M CLDEN, M CL ENTRYENTRY ENTRYENTRY TUBTUB M BEDM BED 8080 SGD8080 SGD 12/0 80 SGD12/0 80 SGD 6060 XO6060 XO 5050 XO5050 XO 2040 SH2040 SH 3080 DOOR3080 DOOR 2660 SH2660 SH 3080 DOOR3080 DOOR 1660 P TEMP1660 P TEMP 5050 XO TEMP5050 XO TEMP 2650 SH2650 SH 6464 9696 3636 5050 88 N/AN/A 4545 N/AN/A 1212 2525 2525 78"78" 78"78" 78"78" SINKSINK 72"72" 9' CLG9' CLG 11 11/202011/2020 PARANADAPARANADA