HomeMy WebLinkAboutBLD2021-00038 - 03 ENERGY WORKSHEETSimple Heating System Size: Washington State
Project Information Contact Information
Heating System Type:
To see detailed instructions for each section, place your cursor on the word "Instructions".
Design Temperature
Instructions Design Temperature Difference (∆T)45
∆T = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)1,248
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height (ft)9.0 11,232
Glazing and Doors U-Factor X Area =UA
Instructions 0.250 314 78.50
Skylights U-Factor X Area =UA
Instructions 0.50 ---
Insulation
Attic U-Factor X Area =UA
Instructions 0.026 1,248 32.45
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions No selection ---
Above Grade Walls (see Figure 1)U-Factor X Area UA
Instructions 0.056 1,018 57.01
Floors U-Factor X Area UA
Instructions 0.029 1,248 36.19
Below Grade Walls (see Figure 1)U-Factor X Area UA
Instructions No selection ---
Slab Below Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Slab on Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Location of Ducts
Instructions Duct Leakage Coefficient
1.00
Sum of UA 204.15
Envelope Heat Load 9,187 Btu / Hour
Sum of UA X ∆T
Air Leakage Heat Load 5,459 Btu / Hour
Volume X 0.6 X ∆T X .018
Building Design Heat Load 14,645 Btu / Hour
Air Leakage + Envelope Heat Loss
Building and Duct Heat Load 14,645 Btu / Hour
Ducts in unconditioned space: Sum of Building Heat Loss X 1.10
Ducts in conditioned space: Sum of Building Heat Loss X 1
Maximum Heat Equipment Output 18,307 Btu / Hour
Building and Duct Heat Loss X 1.40 for Forced Air Furnace
Building and Duct Heat Loss X 1.25 for Heat Pump
This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling
loads.
Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section,
some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension
Program at (360) 956-2042 for assistance.
ALFRED & SUSAN LATHAM
251 KENNEDY ROAD, PORT HADLOCK, WA 98339
Parcel 901033007
HiLine Homes
253-840-1849
Above Grade
Below Grade
Figure 1.
All Other Systems Heat Pump
(07/01/13)
2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies
Conditioned Floor Area 1,248
Component Performance, R occupancies Code Target Values Proposed Design
Area UA Area UA
Doors U =0.300 56 17 56 11
Overhead Glazing U =0.500 0 0 0 0
Vertical Glazing U =0.300 187 56 258 64
Flat/Vaulted Ceilings U =0.026 1,248 32 1,248 34
Wall (above grade) U =0.056 1,089 61 1,018 51
Floors U =0.029 1,248 36 1,248 36
Slab on Grade F =0.540 0 0 0 0
Below Grade Wall U =0.042 0 0 0 0
Below Grade Slab F =0.570 0 0 0 0
Target UA Total 202 Proposed UA Total 196
Target Credits from Table 406.2 1.5 1.5
Qualifies, please check for complete Component Desriptio
Exterior Doors
Plan Component Door
ID Description Ref.U Qt.Feet Inch Feet Inch Area UA
54.00 Custom 0.20 1 3 6 8 20 4
54.00 Custom 0.20 2 2 8 6 8 36 7
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
56 11
Overhead Glazing:
Plan Component Glazing
ID Description Ref.U Qt.Feet Inch Feet Inch Area UA
90.00 0 0.00 0 0
89.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
0 0
Height
ALFRED & SUSAN LATHAM
251 KENNEDY ROAD, PORT HADLOCK, WA 98339
Parcel 901033007
Proposed Credits from
Table 406.2
If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406.2 are ≥ those required in Section R406.2, then
the home meets the 2015 WSEC.
Sum of Area and UA
Sum of Area and UA
Width Height
Width
Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/21/2020 1 of 4
2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies
Vertical Glazing
Plan Component Glazing Width
ID Description Ref.U Qt.Feet Inch Feet Inch Area UA
212.00 MFR 0.25 3 6 6 108 27
212.00 MFR 0.25 1 6 5 30 8
214.00 MFR 0.22 1 5 6 1 6 1
212.00 MFR 0.25 3 4 6 72 18
212.00 MFR 0.25 1 4 4 6 18 5
212.00 MFR 0.25 1 3 4 12 3
214.00 MFR 0.22 1 2 8 1 3 1
214.00 MFR 0.22 1 2 5 10 2
220.00 0 0.00 0 0
221.00 0 0.00 0 0
220.00 0 0.00 0 0
220.00 0 0.00 0 0
219.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
1.00 0 0.00 0 0
Sum of Area and UA 258 64
Glazing Area Weighted U 0.248
Flat/Vaulted Ceilings
Plan Component Attic
Height
Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/21/2020 2 of 4
2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies
ID Description Ref.U Area UA
10.00 10-7 0.027 1,248 34
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
1,248 34
Walls (Above Grade)
Plan Component Wall
ID Description Ref.U Net Area UA
874.00 Custom 0.050 1,018 51
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
1,018 51
Floor (over crawl or exterior)
Plan Component Floor
ID Description Ref.U Area UA
61.00 Custom 0.029 1,248 36
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
1,248 36
Slab on Grade (less than 2 feet below grade)
Plan Component Slab Slab
ID Description Ref.F Length UA
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
0 0
Below Grade Walls and Slabs
Plan Component Wall Wall Slab Slab
ID Description Ref.U Area Length UA
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
1.00 0 0.000 0
Sum of Area, Length and UA 0 0 0
Sum of Area and UA
0.0
UA
0.0
0.0
0.0
0.0
Wall
Sum of Area and UA
0.000
0.000
0.000
0.000
Slab
F
Sum of Area and UA
Sum of Area and UA
Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/21/2020 3 of 4
2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies
Opt.Description
1a Efficient Building Envelope 1a
1b Efficient Building Envelope 1b
1c Efficient Building Envelope 1c
1d Efficient Building Envelope 1d
2a Air Leakage Control and Efficient Ventilation 2a
2b Air Leakage Control and Efficient Ventilation 2b
2c Air Leakage Control and Efficient Ventilation 2c
3a High Efficiency HVAC 3a
3b High Efficiency HVAC 3b
3c High Efficiency HVAC 3c
3d High Efficiency HVAC 3d 1.0
4 High Efficiency HVAC Distribution System
5a Efficient Water Heating 5a 0.5
5b Efficient Water Heating 5b
5c Efficient Water Heating 5c
5d Efficient Water heating 5d
6 Renewable Electric Energy kWh
Total Credits 1.5
*Please refer to Table R406.2 for complete option descriptions
0.5
1.5
0.5
0.5
1.0
1.0
0.5
1.0
1.5
1.0
Credit(s)
0.5
1.0
2.0
0.5
1.0
Table R406.2 Summary
1.0
1.5
Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/21/2020 4 of 4