Loading...
HomeMy WebLinkAboutBLD2021-00157 - 07A STRUCTURAL CALCULATION ENGINEERING SCOPE OF WORK  Lateral Force Resisting System (LFRS) for entire structure. o Lateral Force Resisting System (LFRS) for new or remodeled structure, and any new load into existing structure exceeding 10% increase. o Lateral Force Resisting System (LFRS) (partial) as identified in attached.  Beams [all*] [partial]  Isolated Footings [all*] [partial]  Foundation [all*] [partial]  Basement wall [all*] [partial] o walls that are 9'-0" and higher. o walls with more than a 4' high unbalanced fill. o walls abutting garage slabs (surcharge) o Retaining wall as identified in attached.  Stud walls which exceed 10’-0” height sole to top plate as identified in attached. o Structural Assessment. o Other _______________________ * All = features not covered under IBC/IRC Prescriptive Design Method Kenneth H Swartz, PE Swartz Engineering INFORMATION PROVIDED TO ME Kenneth H Swartz, PE Swartz Engineering 61 " C L E A R HU T C H DBL OVEN 2/4 2/ 4 P D 2/6 9'-0" x 8'-0"9'-0" x 8'-0" 3/0 SC w/CL20 min RATED BR O O M CL O S E T 2/6 DN GA S F I R E P L A C E GARAGE ENTRY STUDY GREAT ROOM KITCHEN DINING ROOM PANTRY UTILITY PWDR PORCH DECK 3/0 WA L K - I N C L O S E T WA L K - I N C L O S E T MASTER BEDROOM MASTER BATH 1/7 x 5/1 TRANS ABV D W GAS ELEC. 4/ 0 B I - F O L D DR A I N P A N 5/0 x 6/4 PW 3/0 x 5/0 SH TRANS ABV 3/ 0 x 2 / 6 P W 3/ 0 x 2 / 6 P W 6/0 x 5/0 PW3/0 x 5/0 SH 3/0 x 5/0 SH 3/0 x 3/6 SH3/0 x 5/0 SH 3/0 x 5/0 SH 12/0 SGD 2/ 6 x 5 / 0 P W 4/ 6 x 5 / 0 P W 1/7 x 5/1 TRANS ABV 3/ 0 x 5 / 0 S H TR A N S A B V 3/ 0 x 2 / 0 S L 3/ 0 x 2 / 0 S L 3/ 0 x 2 / 0 S L GAS FIREPLACE 3/4 WALL EGRESS HOOD ABV 4/ 0 B I - F O L D LI N E N 360 981 7858 kbmonaco@ hotmail.com Owner, Contractor & Builders are to comply with all current IRC Codes. All Dimensions are to be verified by the contractor before the start of construction K. B. M O N A C O PO Box 3050 Silverdale, WA. 98383 SHEET A1 of A9 SHEET TITLE SCALE 1/4" = 1'-0" FINALS: DRAWING TIMELINE 01/14/2021 BU I L D E R S DE S I G N G R O U P 1,593 PLAN DETAILS MAIN FLOOR: GARAGE: YAAKOV & MIREY VAROL PROJECT see ENGINEERING FOR ALL LATERAL & GRAVITY CALCULATIONS PORCH: LOWER FLOOR: MAIN FLOOR DECK: TOTAL HEATED: 613 (527) (39) (293) 2,206 Jefferson County Design Criteria: Roof Snow Load: Seismic Zone: Wind Load 2015 Uniform Plumbing Code, (UPC), 51-56 2015 Washington State Energy Code (WSEC) WAC 51-11R 2015 International Fuel Gas Code, (IFGC), 51-52-003 2015 International Mechanical Code, (IMC) D1, *West End D2 25 PSF 110 MPH w/ 3 second gust 130 MPH w/ 3second gust Frost Depth: 12" below grade 2015 IRC Residential Code, WAC 51-51-003 Brinnon & *West End 30 PSF Wind Load *West End B,C or D depending on conditionsWind Exposure: 1,500 lbs unless there is aSoil Bearing Capacity: geotechnical report *West End is: Forks, Queets, etc. LOWER FLOOR:(827) (heated) (unheated) FURN WH GLASS PANEL ON36" (h) STEM WALL PIPE BOLLARD or APPROVED VEHICLE BARRIER 63'-9 1/2" 28'-3 1/2"16'-0"15'-0"4'-6" 8'-3"5'-0"15'-0 1/2" 4'-3 1/2"10'-0" VT O VTO 3'-3 3/4"5'-0"5'-0" 52 ' - 0 " 17 ' - 0 " 10 ' - 0 " 4' - 0 " 6' - 0 " 4' - 9 1 / 4 " 5' - 0 " 5' - 2 3 / 4 " 2'-0" 3' - 0 " 11 ' - 0 " 63'-9 1/2" 16'-6"13'-0"24'-0" 2'-0"9'-0"2'-0"9'-0"2'-0" 2'-6"8'-0"4'-5 1/4" 8'-9"7'-9" 20 ' - 0 " 5 1/2" 7' - 6 1 / 4 " 2' - 6 1 / 4 " 2' - 6 1 / 4 " 4'-6" 2'-5 3/4" 10 ' - 5 1 / 2 " 2' - 2 3 / 4 " 3' - 2 3 / 4 " 52 ' - 0 " 22 ' - 0 " 13 ' - 0 " 17 ' - 0 " 12 ' - 3 " 4' - 9 " 3' - 1 " 9' - 1 1 " 2' - 7 1 / 4 " 4'-3"3'-2"3'-9"5'-8 1/2" 14'-3 1/2"7'-1"3'-0"7'-2"2'-0"2'-7" 7'-9"16'-5" 11 ' - 0 " 7'-3"2'-7"31'-2"2'-6"5'-0"4'-6" 5' - 7 " 3' - 6 1 / 2 " 5'-9"2'-6"5'-0" 7' - 1 1 1 / 2 " 3' - 0 " 9' - 1 1 / 2 " 6'-0" 4' - 0 " 3' - 1 " 4' - 1 0 1 / 2 " 6'-5 1/2"7'-1" 4' - 5 1 / 2 " 5' - 9 " 19 ' - 9 1 / 2 " 4' - 4 " 5' - 1 0 " 9' - 7 1 / 2 " 2'-3 1/2" 12'-0"2'-7" 5' - 5 1 / 2 " 4' - 5 1 / 2 " 2' - 5 1 / 2 " 4' - 0 " 13'-8"16'-5"6' - 5 1 / 2 " 3'-2"3'-2" 9' - 7 " 3' - 2 " 15 ' - 5 " RO D & S H E L F RO D & S H E L F SHELVES STEPS TO GRADE STEPS TO GRADE CONCRETE / COVERED SLOPE TO DRAIN 4" CONCRETE SLAB TEMP. GL.TEMP. GL. TEMP. GL. TEMP. GL. CO 50 cfm 50 cfm 50 cfm 100 cfm 19 ' - 6 1 / 2 " COVERED 2'-7 1/4" 4'-0"6'-3 1/2" A8 A8 PUMPHEAT min EF of 2.0 min HSPF of 9.0 1.0 GPMor LESS 1.0 GPMor LESS 1.0 GPMor LESS 1.0 GPMor LESS 1.75 GPMor LESS 1.75 GPMor LESS BEDROOM #2 WALK-IN CLOSET BATH FAMILY ROOM UNHEATED STORAGE UP STEP FOUNDATION TO SUIT FINAL GRADE STEP FOUNDATION TO SUIT FINAL GRADE CRAWL SPACE 2/6 2/6 2/0 BF 2/4 LINEN 3' - 0 " x 5 ' - 0 " SH O W E R 6/0 x 2/6 PW3/0 x 5/0 SH 3/0 x 5/0 SH 3/0 x 5/0 SH3/0 x 5/0 SH 2/6 3/0 x 5/0 SH 3/0 x 5/0 SH EGRESS 3/0 HL w/ SCREEN 6/0 x 2/6 PW CRAWL SPACE ACCESS 360 981 7858 kbmonaco@ hotmail.com K. B. M O N A C O PO Box 3050 Silverdale, WA. 98383 SHEET A2 of A9 SHEET TITLE SCALE 1/4" = 1'-0" BU I L D E R S DE S I G N G R O U P see ENGINEERING FOR ALL LATERAL & GRAVITY CALCULATIONS LOWER FLOOR YAAKOV & MIREY VAROL PROJECT *ALL GLAZING IN SIDE HINGED DOORS TO BE SAFETY GLAZING GARAGE DWELLING SEPARATION: R302.5, R309.1 Garage dwelling separation, garage floor. The garage shall be separated from the residence and its attic area by not less than ½” gypsum board applied to the garage side, including garages located less than 3’ from a dwelling unit on the same lot. Garages beneath habitable rooms shall be separated from all habitable rooms above by not less than 5/8” Type X gypsum board and shall be installed perpendicular to the ceiling framing and be fastened at 6” o.c. by minimum 1-7/8” 6d coated nails or equivalent drywall screws. Structural members supporting the horizontal separation shall be protected by minimum ½” gypsum board (this includes all bearing walls, posts, columns, etc.). Ducts in the garage and ducts penetrating the walls or ceilings separating the dwelling from the garage shall be constructed of a minimum No.26 gage sheet steel or other approved material and shall have no openings in the garage. Openings around vents, pipes, ducts, cables, and wires shall be fire blocked with an approved material to resist the passage of flame and products of combustion. The garage floor shall be of concrete or other approved noncombustible material, and shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway. A carport (open on at least 2 sides) may have a floor surface of asphalt. 302.5.1. Garage dwelling door. Openings from a private garage directly into a room used for sleeping purposes shall not be permitted. Other openings between the garage and residence shall be equipped with solid wood doors not less that 1-3/8” in thickness, solid or honeycomb core steel doors not less than 1-3/8” thick, or 20-minute fire-rated doors equipped with a self closing device. For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm. Garage - Dwelling Separation: Table R302.6 Not less than 1/2-inch gypsum board or equivalentFrom the residence and attics From habitable rooms above the garage Not less than 5/8-inch Type X gypsum board or equivalent Structure(s) supporting floor/ceiling assemblies Not less than 1/2-inch gypsum board or equivalent Garages located less than 3 feet from a dwelling unit on the same lot Not less than 1/2-inch gypsum board or equivalent applied to the interior side of exterior walls that are within this area applied to the garage side used for separation required by this section SEPARATION MATERIAL SAFETY GLAZING 1) Safety glazing is required in the following areas shown below. Please label all required safety glazing in applicable locations on the plans. a. In bathrooms where glazing is within 60" horizontally from tubs/ showers and/ or within 60 vertically from tub/ shower floor b. Adjacent to doors where the window edge is within 24 of door arc. c. Glazing greater than 9 square feet where bottom edge is within 18 above walking surface and top edge is greater than 36 above walking surface. d. Glazing adjacent to stairs where the bottom edge of the glazing is within 36" above the plane of the adjacent walking surface of the stairway. TEMP. GL.TEMP. GL. ROD & SHELF CO 50 cfm 63'-9 1/2" 15'-0"16'-0"28'-3 1/2" 2'-7 1/4"5'-0"5'-0"3'-3 3/4"5'-0"5'-0"2'-6"10'-0" 35 ' - 0 " 3' - 0 " 2' - 0 " 13 ' - 0 " 17 ' - 0 " 35 ' - 0 " 10 ' - 0 " 15 ' - 0 " 4' - 0 " 6' - 0 " 4' - 8 " 6' - 0 " 13 ' - 4 " 6' - 0 " 21'-6 1/2"6'-10"4'-10" 6' - 8 " 1' - 3 " 4' - 9 " 6'-8"7'-1" 17'-8 1/2" 6' - 1 1 / 2 " 2' - 3 " 11 ' - 1 0 1 / 2 " 1' - 9 " 5'-0"3'-5 1/2"5'-5 1/2"3'-2"3'-9"3'-11 1/2" 63'-9 1/2" 16'-6"13'-3 1/2"27'-8 1/2"6'-3 1/2" 7'-7 1/2"8'-10 1/2"7'-9 1/2"5'-6" 11 ' - 4 1 / 2 " 3'-2" NOTES A8 A8 1.75 GPMor LESS 1.0 GPMor LESS AL C O V E 5' - 2 3 / 4 " 5' - 0 " 4' - 9 1 / 4 " 2'-0"2'-6" 9' - 1 0 " + / - 12 ' - 0 " + / - PLATE LINE PLATE LINE MAIN FLOOR 9' - 0 " 6' - 1 0 5 / 8 " PLATE LINE HEADER TOP OF SLAB 9' - 0 " 6' - 1 0 5 / 8 " 9' - 5 " 10 ' - 6 " PLATE LINE PLATE LINE MAIN FLOOR FRONT ELEVATION REAR ELEVATION 6/0 x 2/6 PW 3/0 x 2/6 PW 3/0 x 2/6 PW 6/0 x 2/6 PW 3/0 x 2/6 PW 3/0 x 2/6 PW 3/0 x 2/6 PW 5/9 x 2/6 PW 5/9 x 2/6 PW 360 981 7858 kbmonaco@ hotmail.com K. B. M O N A C O PO Box 3050 Silverdale, WA. 98383 SHEET A3 of A9 SHEET TITLE SCALE 1/4" = 1'-0" BU I L D E R S DE S I G N G R O U P see ENGINEERING FOR ALL LATERAL & GRAVITY CALCULATIONS ELEVATIONS YAAKOV & MIREY VAROL PROJECT R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches within the first 10 feet. Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches of fall within 10 feet, drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet of the building foundation shall be sloped a minimum of 2 percent away from the building. SOFFIT (unventilated) SOFFIT (ventilated) TO WINDOW THAT MAY BE OPENED EXTERIOR VENT TERMINATION 15 " m i n 18 " m i n 12 " m i n A B O V E G R A D E 12" min CLEARANCE - OWNER VERIFY ALL SIDING & TRIM DETAILS - CONCRETE PAD PT 6x6 POST / TYP STEPS TO GRADE 6' - 1 0 5 / 8 " HEADER METAL ROOF METAL ROOF METAL ROOF HARDI PLANK METAL ROOF BU I L T - U P C O L U M N S A S P E R O W N E R 112 112 1 12 1 12 9' - 0 " 12 ' - 0 " + / - 6' - 1 0 5 / 8 " HEADER PLATE LINE PLATE LINE TOP OF SLAB MAIN FLOOR 9' - 6 " PLATE LINE MAIN FLOOR 9' - 5 " 10 ' - 6 " 9' - 0 " 12 ' - 0 " + / - 6' - 1 0 5 / 8 " HEADER PLATE LINE PLATE LINE TOP OF SLAB MAIN FLOOR CRICKET CRICKET LEFT ELEVATION RIGHT ELEVATION SITE VERIFY ALL UPPER WINDOWS 360 981 7858 kbmonaco@ hotmail.com K. B. M O N A C O PO Box 3050 Silverdale, WA. 98383 SHEET A4 of A9 SHEET TITLE SCALE 1/4" = 1'-0" BU I L D E R S DE S I G N G R O U P see ENGINEERING FOR ALL LATERAL & GRAVITY CALCULATIONS ELEVATIONS YAAKOV & MIREY VAROL PROJECT PT 6x6 POST / TYP - OWNER VERIFY ALL SIDING & TRIM DETAILS - 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 2'-0" 6' - 1 0 5 / 8 " HEADER PLATE LINE MAIN FLOOR 9' - 6 " METAL ROOFPROVIDE DRIP EDGE METAL ROOF PROVIDE DRIP EDGE HARDI PLANK HARDI PLANK HARDI PLANK HARDI PLANK HARDI PLANK HARDI PLANK CULTURED STONEHARDI PLANK STEP FOUNDATION TO SUIT FINAL GRADE STEP FOUNDATION TO SUIT FINAL GRADE BU I L T - U P C O L U M N S A S P E R O W N E R CRAWL SPACE ACCESS: R408.4 Access. Access sKDOO Ee SURYLGeG .. DOO XQGeUIORRU sSDces. Access RSeQLQJs WKURXJK WKe IORRU sKDOO Ee D PLQLPXP RI 8 LQcKes E\ 4 LQcKes. 2SeQLQJs WKURXJK D SeULPeWeU ZDOO sKDOO Ee QRW Oess WKDQ  LQcKes E\ 4 LQcKes. WKeUe DQ\ SRUWLRQ RI WKe WKURXJKZDOO Dccess Ls EeORZ JUDGe DQ DUeDZD\ QRW Oess WKDQ  LQcKes E\ 4 LQcKes sKDOO Ee SURYLGeG. 7Ke ERWWRP RI WKe DUeDZD\ sKDOO Ee EeORZ WKe WKUesKROG RI WKe Dccess RSeQLQJ. 7KURXJK ZDOO Dccess RSeQLQJs sKDOO QRW Ee ORcDWeG XQGeU D GRRU WR WKe UesLGeQce. See SecWLRQ 00..4 IRU Dccess UeTXLUePeQWs ZKeUe PecKDQLcDO eTXLSPeQW Ls ORcDWeG XQGeU IORRUs.  see E1*,1EER,1* )2R ALL PA' )227,1* S,=ES  360 981 7858 NEPRQDcR# KRWPDLO.cRP .. %. 0 2 1 A C 2 P2 %R[ 00 SLOYeUGDOe WA. 88 S+EE7 A5 of A9 S+EE7 7,7LE SCALE 4  0 BU I L D E R S DE S I G N G R O U P see E1*,1EER,1* )2R ALL LA7ERAL *RA9,7< CALC8LA7,21S )281'A7,21 PLA1 <AA.29 0,RE< 9AR2L PR2-EC7 *ARA*E SL2PE 72 'RA,1 4 C21CRE7E SLA% CRAWL SPACE CRAWL SPACE ACCESS     0 08    8 4  48  4  4   0    0  0  0    0  4  0    0    0  0  0       04 04 0    0     0       4    8 0    4  4   8 8   0 4  40  4  0  0   4       4  4  4     8     4    0   8    0    0    0    0           4       4     0   4       4    8          4    0  4     4  4   0  WATER HEATER: Temperature and pressure relief valves shall Ee drained to outside. Drain may not Ee trapped and must terminate no more than 24 inches nor less than . inches from the ground and shall not Ee threaded. All electric hot water heaters shall Ee placed on an R10 pad when located in an unheated space or on a concrete floor. A thermal expansion compression tanN shall Ee installed on water heater tanNs. R403.5.5 Electric water heater insulation. All electric water heaters in unheated spaces or on concrete floors shall Ee placed on an incompressiEle insulated surface with a minimum thermal resistance of R10. M1307.2 Anchorage of appliances. Appliances designed to Ee fixed in position shall Ee fastened or anchored in an approved manner. In Seismic Design Categories D0 D1 and D2 and in townhouses in Seismic Design Category C water heaters and thermal storage units shall Ee anchored or strapped to resist horizontal displacement caused Ey earthTuaNe motion in accordance with one of the following: 1. Anchorage and strapping shall Ee designed to resist a horizontal force eTual to onethird of the operating weight of the water heater storage tanN acting in any horizontal direction. Strapping shall Ee at points within the upper onethird and lover onethird of the appliance·s vertical dimensions. At the lower point the strapping shall maintain a minimum distance of 4 inches aEove the controls. 2. The anchorage strapping shall Ee in accordance with the appliance manufacturer·s recommendations. M1307.3 Elevation of ignition source. Appliances having an ignition source shall Ee elevated such that the source of ignition is not less than 18 inches aEove the floor in garages. )or the purpose of this section rooms or spaces that are not part of the living space of a dwelling unit and that communicate with a private garage through openings shall Ee considered to Ee part of the garage. Exception: Elevation of the ignition source is not required for appliances that are listed as flammable-vapor-ignition resistant. M1307.3.1 Protection from impact. Appliances shall not Ee installed in a location suEMect to vehicle damage except where protected Ey approved Earriers. HANDRAILS: R311.7.8 Handrails. Handrails shall Ee provided on not less than one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 Height. Handrail height measured vertically from the sloped plane adMoining the tread nosing or finish surface of ramp slope shall Ee not less than 34 inches and not more than 38 inches. Exceptions: 1. The use of a volute, turnout or starting easing shall be allowed over the lowest tread. 2. Where handrail fittings or bendings are used to provide continuous transition between flights, transitions at winder treads, the transition from handrail to guard, or used at the start of a flight,the handrail height at the fittings or bendings shall be permitted to exceed 38 inches. R311.7.8.2 Continuity. Handrails for stairways shall Ee continuous for the full length of the flight from a point directly aEove the top riser of the flight to a point directly aEove the lowest riser of the flight. Handrail ends shall Ee returned or shall terminate in newel posts or safety terminals. Handrails adMacent to a wall shall have a space of not less than 1 12 inches Eetween the wall and the handrails. Exceptions: 1. Handrails shall be permitted to be interrupted by a newel post at the turn. 2. The use of a volute, turnout, starting easing or starting newel shall be allowed over the lowest tread. R311.7.8.3. Grip Size. ReTuired handrails shall Ee of one of the following types or provide eTuivalent graspaEility. 1. Type I. Handrails with a circular cross section shall have an outside diameter of not less than 1 14 inches and not greater than 2 inches. If the handrail is not circular it shall have a perimeter dimension of not less than 4 inches and not greater than  14 inches with a cross section of dimension of not more than 2 14 inches. Edges shall have a radius of not less than 0.01 inch. 2. Type II. Handrails with a perimeter greater than  14 inches shall have a graspaEle finger recess area on Eoth sides of the profile. The finger recess shall Eegin within a distance of 34 inch measured vertically from the tallest portion of the profile and achieve a depth of not less than 51 inch within 78 inch Eelow the widest portion of the profile. This reTuired depth shall continue for not less than 38 inch to a level that is not less than 1 34 inches Eelow the tallest portion of the profile. The width of the handrail aEove the recess shall Ee not less than 1 14 inches and not more than 2 34 inches. Edges shall have a radius of not less than 0.01 inch. STAIRS R3117.5.1 Risers. The riser height shall Ee not more than 734 inches. The riser shall Ee measured vertically Eetween leading edges of the adMacent treads. The greatest riser height within any flight of stairs shall not exceed the smallest Ey more than 38 inch. Risers shall Ee vertical or sloped from the underside of the nosing of the tread aEove at an angle not more than 30 degrees from the vertical. 2pen risers are permitted provided that the openings located more than 30 inches as measured vertically to the floor or grade Eelow do not permit the passage of a 4inchdiameter sphere. Exceptions: 1. The opening Eetween adMacent treads is not limited on spiral stairways. 2. The riser height of spiral stairways shall Ee in accordance with Section R311.7.10.1. R311.7.5.2 Treads. The tread depth shall Ee not less than 10 inches. The tread depth shall Ee measured horizontally Eetween the vertical planes of the foremost proMection of adMacent treads and at a right angle to the tread·s leading edge. The greatest tread depth within any flight of stairs shall not exceed the smallest Ey more than 38 inch. R311.7.5.3 Nosings. The radius of curvature at the nosing shall Ee not greater than 1 inch 14 mm . A nosing proMection not less than 34 inch and not more than 114 inches shall Ee provided on stairways with solid risers. The greatest nosing proMection shall not exceed the smallest nosing proMection Ey more than 38 inch Eetween two stories including the nosing at the level of floors and landings. %eveling of nosings shall not exceed 12 inch . Exception: A nosing proMection is not reTuired where the tread depth is not less than 11 inches. R311.7.5.4 Exterior plastic composite stair treads. Plastic composite exterior stair treads shall comply with the provisions of this section and Section R507.3. 360 981 7858 NEmonaco# hotmail.com .. %. M 2 N A C 2 P2 %ox 3050 Silverdale WA. 8383 SHEET A6 of A9 SHEET TITLE SCALE 14 1 0 BU I L D E R S DE S I G N G R O U P see ENGINEERING )2R ALL LATERAL GRA9IT< CALC8LATI2NS MAIN )L22R )RAMING <AA.29 MIRE< 9AR2L PR2-ECT 14  L P I ) L 2 2 R - 2 I S T # 1   o  c T2P )L8SH %EARING WALL A%29E T2P )L8SH %EARING WALL %EARING WALL 14  L P I ) L 2 2 R - 2 I S T # 1   o  c 14  L P I ) L 2 2 R - 2 I S T # 1   o  c 14  L P I ) L 2 2 R - 2 I S T # 1   o  c 14  L P I ) L 2 2 R - 2 I S T # 1   o  c 2x 1 0 D E C . - 2 I S T 1   o  c 2x 1 0 D E C . - 2 I S T 1   o  c 2x10 LEDGER 2x10 LEDGER  see ENGINEERING )2R ALL %EAM SI=ES  14  L P I ) L 2 2 R - 2 I S T # 1   o  c N2TES ATTIC VENTS: R806.1 Ventilation required. Enclosed attics and enclosed rafter spaces formed where ceilings are applied directl\ to the underside of roof rafters shall have cross ventilation for each separate space .. ventilating openings protected against the entrance of rain or snow. Ventilation openings shall have a least dimension of 1/16 inch minimum and 1/4 inch maximum. Ventilation openings having a least dimension larger than 1/4 inch shall Ee provided with corrosionresistant wire cloth screening, hardware cloth or similar material with openings having a least dimension of 1/16 inch minimum and 1/4 inch maximum. 2penings in roof framing memEers shall conform to the requirements of Section R802.7. Required ventilation openings shall open directl\ to the outside air. R806.2 Minimum vent area. The minimum net free ventilating area shall Ee 1/150 of the area of the vented space. Exception: The minimum net free ventilation area shall be 1/300 of the vented space provided one or more of the following conditions are met: 1. In Climate =ones 6, 7 and 8, a Class I or II vapor retarder is installed on the warminwinter side of the ceiling. 2. At least 40 percent and not more than 50 percent of the required ventilating area is provided E\ ventilators located in the upper portion of the attic or rafter space. 8pper ventilators shall Ee located no more than 3 feet Eelow the ridge or highest point of the space,measured verticall\, with the Ealance of the required ventilation provided E\ eave or cornice vents. :here the location of wall or roof framing memEers conflicts with the installation of upper ventilators, installation more than 3 feet Eelow the ridge or highest point of the space shall Ee permitted. Total Attic Floor Space: 2,395 (including garage, porch & deck) 1/150 Rule 1,150 square inches net free ventilation needed at exhaust (at or near ridge) 1,150 square inches net free ventilation needed at intake (at or near soffit) 1/300 Rule 575 square inches net free ventilation needed at exhaust (at or near ridge) 575 square inches net free ventilation needed at intake (at or near soffit) R806.3 Vent and insulation clearance. :here eave or cornice vents are installed, insulation shall not Elock the free flow of air. Not less than a 1inch space shall Ee provided Eetween the insulation and the roof sheathing and at the location of the vent. R806.4 Installation and weather protection. Ventilators shall Ee installed in accordance with manufacturer·s instructions. Installation of ventilators in roof s\stems shall Ee in accordance with the requirements of Section R903. Installation of ventilators in wall s\stems shall Ee in accordance with the requirements of Section R703.1.  see EN*INEERIN* F2R A// %EAM SI=ES  360 981 7858 kEmonaco# hotmail.com .. %. M 2 N A C 2 32 %ox 3050 Silverdale, :A. 98383 S+EET A7 of A9 S+EET TIT/E SCA/E 1/4 1 0 BU I L D E R S DE S I G N G R O U P see EN*INEERIN* F2R A// /ATERA/ & *RAVIT< CA/C8/ATI2NS R22F FRAMIN* <AA.2V & MIRE< VAR2/ 3R2-ECT 14  / 3 I R A F T E R S # 2 4  o / c 1 12 %EARIN* :A// 14  / 3 I R A F T E R S # 2 4  o / c 1 12 14  / 3 I R A F T E R S # 2 4  o / c 1 12 14  / 3 I R A F T E R S # 2 4  o / c 1 12 14  / 3 I R A F T E R S # 2 4  o / c 1 12 32C.ET %EAM INT2 :A// 32C.ET %EAM INT2 :A// VA / / E < V A / / E < RI ' * E R22F S+EAT+IN* T2 %E C2NT. 8N'ER A// FI// AREAS / T<3. R303.1.1.1 Blown or sprayed roof/ceiling insulation. 7he thickness of Elownin or sprayed roof/ceiling insulation fiEerglass or cellulose shall Ee written in inches on markers that are installed at least one for eYery 300 sTuare feet throughout the attic space. 7he markers shall Ee affi[ed to the trusses or Moists and marked with the minimum initial installed thickness with numEers a minimum of 1 inch in height. Each marker shall face the attic access opening. Spray polyurethane foam thickness and installed RYalue shall Ee listed on certification proYided Ey the insulation installer. R303.1.2 Insulation mark installation. Insulating materials shall Ee installed such that the manufacturer s RYalue mark is readily oEserYaEle upon inspection.  min. 12 0I1I0U0 R403.1.4 W *R$'E . 12 min. 12 min. *R$'E min. R404.1.4.2 Concrete foundation walls. In Euildings assigned to Seismic 'esign Category '0 '1 or '2 concrete foundation walls that support lightframe walls shall comply with this section and concrete foundation walls that support aEoYegrade concrete walls shall comply with $CI 31 $CI 332 or 3C$ 100 see Section R404.1.3 . In addition to the hori]ontal reinforcement reTuired Ey 7aEle R404.1.2 1  plain concrete walls supporting light frame walls shall comply with the following. 1. Wall height shall not e[ceed  feet. 2. UnEalanced Eackfill height shall not e[ceed 4 feet. 3. 0inimum thickness for plain concrete foundation walls shall Ee 7.5 inches e[cept that  inches is permitted where the ma[imum wall height is 4 feet  inches. )oundation walls less than 7.5 inches in thickness supporting more than 4 feet of unEalanced Eackfill or e[ceeding  feet in height shall Ee proYided with hori]ontal reinforcement in accordance with 7aEle R404.1.2 1  and Yertical reinforcement in accordance with 7aEle R404.1.2 2  R404.1.2 3  R404.1.2 4  R404.1.2 5  R404.1.2   R404.1.2 7 or R404.1.2  . Where 7aEles R404.1.2 2 through R404.1.2  permit plain concrete walls not less than 1o. 4 1o. 13 Yertical Ears at a spacing not e[ceeding 4 inches shall Ee proYided. 0inimum Width W 7hickness 7 for Concrete )ootings / /ight)rame Construction Story 7ype 2f Structure /oad  Bearing 9alue of Soil psf 12 [  aE7$B/E R403.1 1 With /ight )rame Construction 1500 2000 2500 3000 3500 4000 12 [  12 [  12 [  12 [  12 [  Based on Snow /oad / Roof /iYe /oad of 30 psf / see IRC 7aEle for additional loads 1 story / slaE on grade 1 story / with crawl space 1 story plus Easement 2 story / slaE on grade 2 story / with crawl space 2 story plus Easement 3 story / slaE on grade 3 story / with crawl space 3 story plus Easement 13 [  12 [  12 [  12 [  12 [  12 [  1 [  14 [  12 [  12 [  12 [  12 [  12 [  12 [  12 [  12 [  12 [  12 [  17 [  13 [  12 [  12 [  12 [  12 [  12 [  12 [  12 [ 23 [  17 [  14 [  12 [  12 [  12 [ 15 [ 12 [ 12 [  12 [  12 [  12 [ 12 [ 20 [  15 [  13 [  12 [  12 [ 1 [ 2 [  20 [  )or SI: 1 inch 25.4 mm 1 plf 14. 1/m 1 pound per sTuare foot 47. 1/m2. a. Interpolation allowed. E[trapolation is not allowed. E. Based on 32footwide house with loadEearing center wall that carries half of the triEutary attic and floor framing. )or eYery 2 feet of adMustment to the width of the house add or suEtract 2 inches of footing width and 1 inch of footing thickness Eut not less than  inches thick . 0inimum +ori]ontal Reinforcement )or Concrete Basement Walls 0a[imum Unsupported /ocation of +ori]ontal Reinforcement 2ne 4 Ear within 12 of the top of wall story one 4 Ear near mid height of the wall story aE 7$B/E R404.1.2 1 +eight of Basement Wall less than or eTual to  0 greater than  0 )or SI: 1 inch 25.4 mm 1 foot 304. mm 1 pound per sTuare inch .5 k3a. a. +ori]ontal reinforcement reTuirements are for reinforcing Ears with a minimum yield strength of 40000 psi and concrete with a minimum concrete compressiYe strength of 2500 psi. E. See Section R404.1.2.2 for minimum reinforcement reTuired for foundation walls supporting aEoYegrade concrete walls. 2ne 4 Ear within 12 of the top of wall story one 4 Ear near third points of the wall story R403.1.3.1 Concrete stem walls with concrete footings. In Seismic 'esign Categories '0 '1 and '2 where a construction Moint is created Eetween a concrete footing and a concrete stem wall a minimum of one 1o. 4 Yertical Ear shall Ee installed at not more than 4 feet on center. 7he Yertical Ear shall haYe a standard hook and e[tend to the Eottom of the footing and shall haYe support and coYer as specified in Section R403.1.3.5.3 and e[tend a minimum of 14 inches into the stem wall. Standard hooks shall comply with Section R0.5.4.5. $ minimum of one 1o. 4 hori]ontal Ear shall Ee installed within 12 inches of the top of the stem wall and one 1o. 4 hori]ontal Ear shall Ee located 3 to 4 inches from the Eottom of the footing. 4 +2RI=217$/ B$RS S3$CE' WI7+I1 12 2) 7+E 723 2) 7+E W$// R403.1.3.1 and 7$B/E R404.1.2 1 min. 1/2 'I$0E7ER $1C+2R B2/7S S3$CE'  0 o/c ma[. B2/7S S+$// E;7E1' $ min 2) 7 I172 C21CRE7E $1' S+$// BE /2C$7E' I1 7+E 0I''/E 7+IR' 2) 7+E WI'7+ 2) 7+E 3/$7E. $ 1U7 $1' 3/$7E W$S+ER 127 /ESS 7+$1 0.22[3[3 S+$// BE 7I*+7E1E' 21 E$C+ $1C+2R B2/7. 7+ERE S+$// BE $ min 2) 7W2 B2/7S 3ER 3/$7E $1' WI7+I1 12 2) E$C+ E1' 2) SI// B2$R'. 12 WE7 SE77I1* 2 4 +2RI=217$/ REB$R C217I1U2US 7+R2U*+2U7 7+E E17IRE )227I1* S3$CE' $7 /E$S7 3 $B29E 7+E B27720 2) 7+E )227I1* 3rescriptiYe )oundation 'etails )or 7ypical /ight )rame Construction 2 4 +2RI=217$/ REB$R C217I1U2US 7+R2U*+2U7 7+E E17IRE )227I1* S3$CE' $7 /E$S7 3 $B29E 7+E B27720 2) 7+E )227I1* BASEMENT OR CRAWL SPACE WITH CONCRETE STEM WALL & SPREAD FOOTING SLAB ON GROUND WITH MONOLITHIC TURNED-DOWN FOOTING see 7$B/E R403.1 1 Eelow 4 9ER7IC$/ B$RS # 4 o/c per SEC7I21 R403.1.3.1. min 14 I172 S7E0 W$// $1' S7$1'$R' +22. per SEC7I21 R0.5.4.5 4 +2RI=217$/ B$RS S3$CE' WI7+I1 12 2) 7+E 723 2) 7+E W$// R403.1.3.1 and 7$B/E R404.1.2 1 SEE E1* I 1 E E R I 1 * )2R )2 2 7 I 1 * S I = E s Crawlspace $rea:3 sT ft 9entilation ReTuired:3 sT. ft. / 300 [ 144 Use:14 [ 7 )oundation 9ents $ctual 9ent $rea: sTuare inches  25 reduction 1/4 mesh 73.50 sTuare inches 40 sTuare inches reT. 9ents ReTuired:40 sTuare inches / 73.5 9ent $rea 1 Yents reTuired 3roYide: 1 14 [ 7 9ents: 7otal $rea 73.5 sTuare inches 9entilation 3roYided:73.5 sTuare inches 40 sTuare inches reT. 9E17S S+$// 127 I17ER)ERE WI7+ BUI/'I1* C20321E17S SUC+ $S +2/''2W1S see E1*I1EERI1* 72 9ERI)< 3/$CE0E17 R40.1 Concrete and masonry foundation dampproofing. E[cept where reTuired Ey Section R40.2 to Ee waterproofed foundation walls that retain earth and enclose interior spaces and floors Eelow grade shall Ee dampproofed from the higher of a the top of the footing or E  inches Eelow the top of the Easement floor to the finished grade. 0asonry walls shall haYe not less than 3/ inch portland cement parging applied to the e[terior of the wall. 7he parging shall Ee dampproofed in accordance with one of the following: 1. Bituminous coating. 2.7hree pounds per sTuare yard 1.3 kg/m2 of acrylic modified cement. 3.2neeighthinch coat of surfaceEonding cement complying with $S70 C 7. 4.$ny material permitted for waterproofing in Section R40.2. 5.2ther approYed methods or materials. E[ception: 3arging of unit masonry walls is not reTuired where a material is approYed for direct application to the masonry. Concrete walls shall Ee dampproofed Ey applying any one of the listed dampproofing materials or any one of the waterproofing materials R405.1 Concrete or masonry foundations. 'rains shall Ee proYided around concrete or masonry foundations that retain earth and enclose haEitaEle or usaEle spaces located Eelow grade. 'rainage tiles graYel or crushed stone drains perforated pipe or other approYed systems or materials shall Ee installed at or Eelow the area to Ee protected and shall discharge Ey graYity or mechanical means into an approYed drainage system. *raYel or crushed stone drains shall e[tend not less than 1 foot Eeyond the outside edge of the footing and  inches aEoYe the top of the footing and Ee coYered with an approYed filter memErane material. 7he top of open Moints of drain tiles shall Ee protected with strips of Euilding paper. E[cept where otherwise recommended Ey the drain manufacturer perforated drains shall Ee surrounded with an approYed filter memErane or the filter memErane shall coYer the washed graYel or crushed rock coYering the drain. 'rainage tiles or perforated pipe shall Ee placed on a minimum of 2 inches of washed graYel or crushed rock not less than one sieYe si]e larger than the tile Moint opening or perforation and coYered with not less than  inches of the same material. 360 981 7858 kEmonaco# hotmail.com .. B. 0 2 1 $ C 2 32 Bo[ 3050 SilYerdale W$. 33 S+EE7 A8 of A9 S+EE7 7I7/E SC$/E 1/4 1 0 BU I L D E R S DE S I G N G R O U P see E1*I1EERI1* )2R $// /$7ER$/ *R$9I7< C$/CU/$7I21S 7<3IC$/ W$// 'E7$I/ <$$.29 0IRE< 9$R2/ 3R2-EC7 CR2SS SEC7I21 R302.7 Under stair protection: 7he walls and soffits of enclosed usaEle space under stairs shall Ee protected on the enclosed side Ey not less than 1 layer of 1/2 gypsum Eoard. 34   3   +$1 ' R $ I / )$0I/< R220 E17R< *RE$7 R220   0  3/$7E /I1E 3/$7E /I1E 723 2) S/$B 0$I1 )/22R 3/$7E /I1E 0$I1 )/22R   0    0  3/$7E /I1E 723 2) S/$B 11  2   /      m i n 10 min 7 3/ ma[ 72 3$17R< 14 /3I )/22R -2IS7 # 1 o/c 14 /3I R$)7ERS # 2 4  o / c R10 perimeter and entire slaE R21 R21 R21 R21 SECTION A R3 12R0$/ 'E1 S I 7 < B $ 7 7 S . TYPICAL WALL SECTION R21 4 *R$9E/ )I// R$'21 C217R2/ 4 C21CRE7E S/$B U1'IS7URBE' S2I/ 1/2 *WB R21 2 [  S7U'S # 1 o/c 14 /3I )/. -2IS7 # 1 o/c 3/4 7 * U'/ SUB)/22R */UE' 1$I/E' 72 2 [  S7U'S 1 o/c 5/ *WB 1/2 *WB +$R'I 3/$1. SI'I1* 21 7/1 2SB S+E$7+I1* 2 [  B27720 3/$7E 7<9E. +2USE WR$3 I1S7$//E' 72 0$1U). I1S7RUC7I21S 2 [  7RE$7E' SI// 3/$7E / C217I1U2US *R$'E  min. R21 min # RI0 -2IS7 R10 3ERI0E7ER E17IRE S/$B see E/E9$7I21S 9$32R RE7$R'ER 2 2 [  723 3/$7ES 4 [ 10 +E$'ER w / R10 RI'*E' I1SU/$7I21 5/ *WB +URRIC$1E +2/''2W1S R$)7ER 'B/. 2 [  723 3/$7E 12 +URRIC$1E +2/''2W1S C217I1U2US *U77ERS 9E17E' B/2C.I1* w / B$))/E 0E7$/ R22)I1* on 30 )E/7 3$3ER on 14 /3I R$)7ERS # 24 o/c 7/1 2SB or 1/2 C'; on R3 12R0$/ 'E1SI7< B$77S. 'RI3 E'*E )enestration U)actor Skylight Ufactor Ceiling R9alue Wood )rame Wall R9alue 0ass Wall R9alue )loor R9alue SlaE on *rade Efficiency Building EnYelope 1a 0.2 0.50 4 21 int 21 / 21 3 R10 perimeter and entire slaE Below *rade SlaE R10 perimeter and entire slaE 2r compliance Eased on Section R402.4 Reduce the total U$ Ey 5 2015 WSEC 'WE//I1* U1I7 SI=E: 0E'IU0 3R232SE' +E$7I1* S<S7E0:)2RCE' $IR WI7+ +E$7 3U03 3RESCRI37I9E W+2/E +2USE 9E17I/$7I21:I17E*R$7E' WI7+ )2RCE' $IR S<S7E0 'UC7E' )UR1$CE 237I21 $IR)/2W R$7E:0 cfm E1ER*< CRE'I7S:3.5 Credits ReTuired 2ption: E))ICIE17 W$7ER +E$7I1* 5a Credit: 0.5 2ption: E))ICIE17 W$7ER +E$7I1* 5c Credit:1.5 2ption: +I*+ E))ICIE1C< +9$C E4UI30E17 3E Credit: 1.0 2ption: E))ICIE1C< BUI/'I1* E19E/23E 1a Credit:0.5 7otal Credits:3.5 WSEC 5" max 2" min LEDGER STAGGER FASTENERS IN 2 ROWS 5.5" min for 2 x 8* 6.5" min for 2 x 10 2" min 3/4" min 7.5" min for 2 x 12 LAG SCREW or BOLT *Distance shall be permitted to be reduced to 4.5" if lag screws are used or bolt spacing is reduced to that of lag screws to attach 2x8 ledgers to 2x8 band joist Placement of Lag Screws and Bolts in Ledgers / IRC Figure R507.2.1 (1) R507.2.4 Deck lateral load connection. The lateral load connection required by Section R507.1 shall be permitted to be in accordance with Figure R507.2.3(1) or R507.2.3(2). Where the lateral load connection is provided in accordance with Figure R507.2.3(1), hold-down tension devices shall be installed in not less than two locations per deck, within 24 inches of each end of the deck. Each device shall have an allowable stress design capacity of not less than 1,500 pounds. Where the lateral load connections are provided in accordance with Figure R507.2.3(2), the hold-down tension devices shall be installed in not less than four locations per deck, and each device shall have an allowable stress design capacity of not less than 750 pounds. R507.8.1 Deck post to deck footing. Posts shall bear on footings in accordance with Section R403 and Figure R507.8.1. Posts shall be restrained to prevent lateral displacement at the bottom support. Such lateral restraint shall be provided by manufactured connectors installed in accordance with Section R507 and the manufacturers’ instructions or a minimum post embedment of 12 inches in surrounding soils or concrete piers. R317 Protection of wood and wood based products against decay. Pressure treated wood shall be used for those portions of exposed wood members and members subject to wind driven rain, such as within a covered porch, that form the structural supports of buildings, balconies, porches or similar appurtenances, including all joists, beams. , R317.3.1 Fasteners for preservative-treated wood. Fasteners, including nuts and washers, for preservative-treated wood shall be of hot-dipped, zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Coating types and weights for connectors in contact with preservative-treated wood shall be in accordance with the connector manufacturer’s recommendations. A A A GUARDRAIL REQUIRED AT HEIGHTS OVER 30" 36" MINIMUM GUARDRAIL HEIGHT TOP OF RETAINING WALL GRADE OPEN GUARDRAIL A 4" DIAMETER SPHERE CAN'T PASS THROUGH RAILING OPENING LIMITS A Guardrails Deck Beam to Deck Post / IRC Figure 507.7.1 2 1/2" min 5 1/2" min Notched Beam (2) 1/2" DIAMETER THROUGH-BOLTS WITH WASHERS NOTCH POST DECK POST BEAM APPROVED POST CAP DECK POST BEAM Post Cap FLOOR JOIST FLASHING FOR WATER TIGHTNESS Deck Attachment For Lateral Loads / IRC Figure R507.2.3(2) SIDING SHEATHING APPROVED JOIST HANGERS DECKING 2x LEDGER WITH FASTENERS INACCORDANCE WITH TABLE R507.2 AT 4 LOCATIONS, EVENLY DISTRIBUTED ALONG DECK & WITHIN 2" OF EACH END OF THE LEDGER. HOLD-DOWN DEVICES SHALL FULLY ENGAGE DECK JOIST PER HOLD-DOWN MANUFACTURER. HOLD-DOWN DEVICE min 750 LB. CAPACITY A FULLY THREADED 3/4" DIAMETER LAG SCREW PREDRILLED w/min 3" PENETRATION TO CENTER OF TOP PLATE, STUDS, OR HEADER. NOTE: THIS DETAIL IS APPLICABLE WHERE FLOOR JOIST ARE PARALLEL TO DECK JOIST 2" min 2" min Deck Attachment of Guardrail Post Outside Rim Joist 2" 2" *SIMPSON HTT4DECKING (typ) POST JOIST 5/8" DIAMETER MACHINE BOLTS OR THREADED RODS WITH NUTS AND BP5/8 BEARING PLATES 2" 2" *SIMPSON HTT4DECKING (typ) POST RIM JOIST 5/8" DIAMETER MACHINE BOLTS OR THREADED RODS WITH NUTS AND BP5/8 BEARING PLATES JOISTBLOCKINGBLOCKING Detail ADetail B - DETAIL A - HTT4 TO JOIST - DETAIL B - HTT4 TO BLOCKING * INSTALL AS PER MANUFACTURERS INSTRUCTIONS ALT: *DTT2Z OR *DTT2SS WITH SDS 1/4 x 1 1/2" & 1/2" MACHINE BOLT OR THREADED ROD WITH NUTS AND BP1/2 BEARING PLATES FOR MIN. 2x10 LUMBER Deck Attachment of Guardrail Post Inside Rim Joist 2" 2" *SIMPSON HTT4DECKING (typ) POST JOIST 5/8" DIAMETER MACHINE BOLTS OR THREADED RODS WITH NUTS AND BP5/8 BEARING PLATES 2" 2" *SIMPSON HTT4DECKING (typ) POST RIM BOARD 5/8" DIAMETER MACHINE BOLTS OR THREADED RODS WITH NUTS AND BP5/8 BEARING PLATESBLOCKINGBLOCKING Detail ADetail B - DETAIL A - HTT4 TO JOIST - DETAIL B - HTT4 TO BLOCKING BLOCKING (Joist behind) BAND JOIST RIM JOIST BLOCKING BLOCKING BLOCKING DECK JOIST * INSTALL AS PER MANUFACTURERS INSTRUCTIONS ALT: *DTT2Z OR *DTT2SS WITH SDS 1/4 x 1 1/2" & 1/2" MACHINE BOLT OR THREADED ROD WITH NUTS AND BP1/2 BEARING PLATES FOR MIN. 2x10 LUMBER For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 pound per square foot = 0.0479 kPa. a. Ledgers shall be flashed in accordance with Section R703.8 to prevent water from contacting the house band joist. b. Snow load shall not be assumed to act concurrently with live load. c. The tip of the lag screw shall fully extend beyond the inside face of the band joist. d. Sheathing shall be wood structural panel or solid sawn lumber. e. Sheathing shall be permitted to be wood structural panel, gypsum board, fiberboard, lumber or foam sheathing. Up to 1/2-inch thickness of stacked washers shall be permitted to substitute for up to 1/2 inch of allowable sheathing thickness where combined with wood structural panel or lumber sheathing. 1/2-inch diameter lag screw with 1/2-inch maximum sheathing c,d 1/2-inch diameter bolt with 1/2-inch maximum sheathing d 1/2-inch diameter bolt with 1 - inch maximum sheathing e Deck Ledger Connection to Band Joist a,b - Table R507.2 (Deck live load = 60 psf, deck dead load = 10 psf, snow load < 60 psf) Joist Span On-center spacing of fasteners 6' and less 6'-1" to 8'8'-1" to 10'10'-1" to 12'12'-1" to 14'14'-1" to 16'16'-1" to 18' 30 36 36 23 36 36 18 34 29 15 29 24 13 24 21 11 21 18 10 19 16 _ Connection Details 360 981 7858 kbmonaco@ hotmail.com K. B. M O N A C O PO Box 3050 Silverdale, WA. 98383 SHEET A9 of A9 SHEET TITLE SCALE 1/4" = 1'-0" BU I L D E R S DE S I G N G R O U P see ENGINEERING FOR ALL LATERAL & GRAVITY CALCULATIONS DECK DETAILS YAAKOV & MIREY VAROL PROJECT ENGINEERING CALCULATIONS 1. Building Code and Criteria used. • International Building Code (IBC) 2015 edition • International Residential Code (IRC) 2015 edition • ASCE 07-10 2. Overall: Design to life-safety criteria. 3. Seismic, Simplified Method: • S(s) = Mapped Short Period MCE @ 2% = 1.59214 (USGS and IBC); = 1.500 (ASCE 12.14.8) • Site Class D (ASCE paragraph 11.4.2) • I = Importance Factor = 1.0 (ASCE paragraph 11.5.1 and Table 11.5-1) • Fa = Site Coefficient = 1.4 (ASCE paragraph 11.4.3 and paragraph 12.14.8.1) • Sds = Design Acceleration = (2/3)(Fa)(Ss) = (2/3)(1.40)(1.50) = 1.40 (ASCE paragraph 11.4.4 and equation 12.14-11) • Seismic Design Category = D (ASCE paragraph 11.6 and Table 11.6-1) • R = Basis Seismic Force Resisting System Response Modification Coefficient R = 6.5 light frame wood structural panel shearwalls (ASCE Table 12.14-1 A13) • F = 1.0 for one-story, 1.1 for two-story, 1.2 three-story (ASCE paragraph 12.14.8.1) • Rho = 1.0 (ASCE paragraph equation 12.14-5) • Eh = Horizontal Load Effect = (Qe)(Rho) • V = Base Shear = (F)(Sds)/R = F(1.40)/6.5 = (0.21539)(F) (ASCE equation 12.14-11) V = 0.216 one-story; V = 0.237 two-story; V = 0.259 three-story 4. Seismic, Equivalent Lateral Force Method: • S(s) = Mapped Short Period MCE @ 2% = 1.59214 (USGS and IBC) • Site Class D (ASCE paragraph 11.4.2) • I = Importance Factor = 1.0 (ASCE paragraph 11.5.1 and Table 11.5-1) • Fa = Site Coefficient = 1.0 (ASCE paragraph 11.4.3 and Tabel 11.4-1) • Sms = MCE Adjusted for Site Class = (Fa)(Ss) = (1.0)( 1.59214) = 1.59214 • Sds = Design Acceleration = (2/3)(Sms) = (2/3)( 1.59214) = 1.0614 (ASCE paragraph 11.4.4 and equation 11.4-3) • Seismic Design Category = D (ASCE paragraph 11.6 and Table 11.6-1) • R = Basis Seismic Force Resisting System Response Modification Coefficient = 6.5 light frame wood structural panel shearwalls (ASCE Table 12.12-1 A13) • Rho = redundancy factor = 1.3 (ASCE paragraph 12.3.4.2) • Cs = Seismic Response Coefficient = (I)(Sds)/R = (1.0)( 1.0614)/R = 1.0614 /R (ASCE paragraph 12.8.1.1) • Eh = Horizontal Load Effect = (Qe)(Rho) • V = Base Shear = (Cs)(Rho)(W)/R = (1.0614)(Rho)W/R (ASCE Equation 12.8-1) = (1.0614)(1.3)/6.5 = 0.213 light frame wood structural panel shearwalls 5. Wind: • Wind loading per ASCE 7 using Simplified Analysis • 85 mph basic 3-second gust (ASD Method)/110 mph basic 3-second gust (USD Method) • Importance Factor = 1.0 • Exposure | A | B | C | D | 6. Snow Load: • Ground snow load (psf): | 30 | ____ | • Exposure Category (snow): | B | C | D | 7. Gravity: • Roof DL (psf): | 10 | 15 | 20 | 25 (tile) | ____ | • Floor LL (psf): | 40 | 60 | ____ | • Deck LL (psf): | 60 | ____ | • Floor DL(psf): | 10 | 15 | 20 | 25 | 30 (2” LW concrete/ceramic) | ____ | • Floor LL at Hot Tub area (psf): | 100 | 120 | NA | • Allowable soil bearing (psf): | 1500 | 2000 | ____ | WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 1) 1.wsw Jan. 16, 2021 16:54:39 Project Information COMPANY AND PROJECT INFORMATION Company Project Swartz Engineering Kenneth H Swartz, PE PO Box 532 DESIGN SETTINGS Design Code IBC 2018/AWC SDPWS 2015 Wind Standard ASCE 7-16 Directional (All heights) Seismic Standard ASCE 7-16 Load Combinations For Design (ASD) 0.70 Seismic 0.60 Wind For Deflection (Strength) 1.00 Seismic 1.00 Wind Building Code Capacity Modification Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Factor 1.60 Temperature Range T<=100F Moisture Content Fabrication Service 19% (<=19%) 10% (<=19%) Max Shearwall Offset [ft] Plan (within story) 0.50 Elevation (between stories) 1.00 Maximum Height-to-width Ratio Wood panels Wind Seismic Fiberboard Lumber Wind Seismic Gypsum Blocked Unblocked 3.5 3.5 - - - 2.0 1.5 Ignore non-wood-panel shear resistance contribution... Wind Seismic when comb'd w/ wood panels Always Forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall relative rigidity: Deflection-based stiffness of wall segments Perforated shearwall Co factor: SDPWS Equation 4.3-5 Non-identical materials and construction on the shearline: Allowed, except for material type Deflection Equation: 3-term from SDPWS 4.3-1 Drift limit for wind design: 1 / 500 story height Force-transfer strap: Continuous at top of highest opening and bottom of lowest SITE INFORMATION Risk Category Category II - All others Wind ASCE 7-16 Directional (All heights) Seismic ASCE 7-16 12.8 Equivalent Lateral Force Procedure Design Wind Speed 110 mph Exposure Exposure D Enclosure Partially open Structure Type Irregular Building System Bearing Wall Design Category D Site Class D Topographic Information [ft] Shape - Height - Length - Site Location: - Elev: 0ft Rigid building - Static analysis Spectral Response Acceleration S1: 0.600g Ss: 1.600g Fundamental Period E-W N-S T Used 0.197s 0.197s Approximate Ta 0.197s 0.197s Maximum T 0.276s 0.276s Response Factor R 6.50 6.50 Fa: 1.00 Fv: 1.70 Case 2 N-S loadsE-W loads Eccentricity (%)15 15 Loaded at 75% Min Wind Loads: Walls Roofs 16 psf 8 psf Serviceability Wind Speed 85 mph 1 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Structural Data STORY INFORMATION Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft]Depth [in]Height [ft]shrinkage [in]length [in] Ceiling 22.00 0.0 Level 2 13.00 12.0 9.00 15.6 16.4 Level 1 3.00 12.0 9.00 15.6 16.4 Foundation 2.00 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ft]Face Type Slope Overhang [ft] Block 1 2 Story E-W Ridge Location X,Y =0.00 17.00 North Side 90.0 1.50 Extent X,Y =63.75 35.00 South Side 7.0 1.50 Ridge Y Location, Offset 52.00 17.50 East Gable 90.0 1.50 Ridge Elevation, Height 26.30 4.30 West Gable 90.0 1.50 Block 2 2 Story E-W Ridge Location X,Y =29.75 0.00 North Side 90.0 1.50 Extent X,Y =27.75 17.00 South Side 7.0 1.50 Ridge Y Location, Offset 17.00 8.50 East Gable 90.0 1.50 Ridge Elevation, Height 24.09 2.09 West Gable 90.0 1.50 2 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEATHING MATERIALS by WALL GROUP Sheathing Fasteners Apply Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes in in lbs/in in in 1 Both Structural sheath 24/16 7/16 -3 Vert 27000 10d Nail N 2 12 Y 2,3 2 Ext Structural sheath 24/16 7/16 - 3 Vert 27000 8d Nail N 4 12 Y 2,3 3 Ext Structural sheath 24/16 7/16 - 3 Vert 27000 8d Nail N 3 12 Y 2,3 4 Ext Structural I 24/16 7/16 -3 Horz 35000 10d Nail N 2 12 Y 2,3 Legend: Grp – Wall Design Group number, used to reference wall in other tables (created by program) Surf – Exterior or interior surface when applied to exterior wall Ratng – Span rating, see SDPWS Table C4.2.2.2C Thick – Nominal panel thickness GU - Gypsum underlay thickness Ply – Number of plies (or layers) in construction of plywood sheets Or – Orientation of longer dimension of sheathing panels Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B Type – Fastener type from SDPWS Tables 4.3A-D: Nail – common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing – casing nail; Roof – roofing nail; Screw – drywall screw Size - Common, box, and casing nails: refer to SDPWS Table A1 (casing sizes = box sizes). Gauges: 11 ga = 0.120” x 1-3/4” (gypsum sheathing, 25/32” fiberboard ), 1-1/2” (lath & plaster, 1/2” fiberboard); 13 ga plasterboard = 0.92” x 1- 1/8”. Cooler or gypsum wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4” long. 5/8” gypsum sheathing can also use 6d cooler or GWB nail Df – Deformed nails ( threaded or spiral), with increased withdrawal capacity Eg – Panel edge fastener spacing Fd – Field spacing interior to panels Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes – Notes below table legend which apply to sheathing side Notes: 2. Framing at adjoining panel edges must be 3" nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4 3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or panel orientation is horizontal. See SDPWS T4.3A Note 2. FRAMING MATERIALS and STANDARD WALL by WALL GROUP Wall Species Grade b d Spcg SG E Standard Wall Grp in in in psi^6 1 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmitted 2 2x 2 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Perforated 4 3 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmented 3 4 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmented - 2 Legend: Wall Grp – Wall Design Group b – Stud breadth (thickness) d – Stud depth (width) Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. SG – Specific gravity E – Modulus of elasticity Standard Wall - Standard wall designed as group. Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. 3 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEARLINE, WALL and OPENING DIMENSIONS North-south Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group X [ft] Start End [ft] [ft] Ratio [ft] Line 1 Level 2 Line 1 2 0.00 17.00 27.00 10.00 6.00 - 9.00 Wall 1-1 Prf 2 0.00 17.00 27.00 10.00 6.00 - - Segment 1 -- 17.00 23.00 6.00 6.00 1.50 - Opening 1 -- 23.00 26.00 3.00 3.00 - 5.00 Segment 2 -- 26.00 27.00 1.00 1.00 9.00 - Level 1 Line 1 Seg 1 0.00 17.00 27.00 10.00 10.00 - 9.00 Wall 1-1 Seg 1 0.00 17.00 27.00 10.00 10.00 0.90 - Line 2 Level 2 Line 2 2 4.50 17.00 42.00 25.00 0.00 - 9.00 Wall 2-1 Prf 2 4.50 27.00 42.00 15.00 0.00 - - Segment 1 -- 27.00 27.75 0.75 0.75 12.00 - Opening 1 -- 27.75 30.75 3.00 3.00 - 2.50 Segment 2 -- 30.75 32.25 1.50 1.50 6.00 - Opening 2 -- 32.25 37.25 5.00 5.00 - 8.00 Segment 3 -- 37.25 37.75 0.50 0.50 18.00 - Opening 3 -- 37.75 40.75 3.00 3.00 - 2.50 Segment 4 -- 40.75 42.00 1.25 1.25 7.20 - Level 1 Line 2 Prf 2 4.50 17.00 42.00 25.00 15.00 - 9.00 Wall 2-1 Prf 2 4.50 27.00 42.00 15.00 15.00 0.60 - Line 3 Level 2 Line 3 Prf 2 8.50 17.00 42.00 25.00 9.50 - 9.00 Wall 3-1 Prf 2 8.50 17.00 26.50 9.50 9.50 0.95 - Level 1 Line 3 Prf 2 7.75 17.00 42.00 25.00 10.25 - 9.00 Wall 3-1 Prf 2 7.75 17.00 27.25 10.25 10.25 0.88 - Line 4 Level 2 Line 4 Seg 4 16.50 17.00 42.00 25.00 3.00 - 9.00 Wall 4-1 Seg 4 16.50 17.00 20.00 3.00 3.00 3.00 - Level 1 Line 4 Seg 1 16.50 17.00 42.00 25.00 3.00 - 9.00 Wall 4-1 Seg 1 16.50 17.00 20.00 3.00 3.00 3.00 - Line 5 Level 2 Line 5 2 19.50 20.00 46.00 26.00 0.00 - 9.00 Wall 5-1 Prf 2 19.50 42.00 46.00 4.00 0.00 - - Segment 1 -- 42.00 42.75 0.75 0.75 12.00 - Opening 1 -- 42.75 45.25 2.50 2.50 - 4.50 Segment 2 -- 45.25 46.00 0.75 0.75 12.00 - Level 1 Line 5 Prf 2 19.50 20.00 46.00 26.00 3.56 - 9.00 Wall 5-1 Prf 2 19.50 42.00 46.00 4.00 3.56 2.25 - Line 6 Level 1 Line 6 NSW 22.25 32.50 40.50 8.00 0.00 - 9.00 Wall 6-1 NSW 22.25 32.50 40.50 8.00 0.00 1.00 - Line 7 Level 2 Line 7 2 29.75 0.00 46.00 46.00 17.00 - 9.00 Wall 7-1 Prf 2 29.75 0.00 20.00 20.00 17.00 - - Segment 1 -- 0.00 9.50 9.50 9.50 0.95 - Opening 1 -- 9.50 12.50 3.00 3.00 - 2.00 Segment 2 -- 12.50 20.00 7.50 7.50 1.20 - Wall 7-2 Prf 2 29.75 20.00 22.00 2.00 0.00 4.50 - Level 1 Line 7 1 29.75 0.00 46.00 46.00 20.00 - 9.00 Wall 7-1 Seg 1 29.75 0.00 20.00 20.00 20.00 0.45 - Wall 7-2 Seg 1 29.75 20.00 22.00 2.00 0.00 4.50 - Line 8 Level 2 Line 8 2 35.50 0.00 52.00 52.00 0.00 - 9.00 Wall 8-1 Prf 2 35.50 46.00 52.00 6.00 0.00 - - Segment 1 -- 46.00 47.50 1.50 1.50 6.00 - Opening 1 -- 47.50 50.50 3.00 3.00 - 6.67 Segment 2 -- 50.50 52.00 1.50 1.50 6.00 - 4 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Level 1 Line 8 2 35.69 0.00 52.00 52.00 25.25 - 9.00 Wall 8-1 Prf 2 35.75 26.75 46.00 19.25 19.25 0.47 - Wall 8-2 Prf 2 35.50 46.00 52.00 6.00 6.00 1.50 - Line 9 Level 2 Line 9 NSW 38.00 32.00 42.25 10.25 0.00 - 9.00 Wall 9-1 NSW 38.00 32.00 42.25 10.25 0.00 1.00 - Line 10 Level 2 Line 10 50.25 32.00 52.00 20.00 0.00 - 9.00 Wall 10-1 NSW 50.25 32.00 40.00 8.00 0.00 1.00 - Wall 10-2 NSW 50.25 43.00 52.00 9.00 0.00 1.00 - Line 11 Level 2 Line 11 2 53.50 0.00 52.00 52.00 19.00 - 9.00 Wall 11-1 Prf 2 53.50 0.00 22.00 22.00 19.00 - - Segment 1 -- 0.00 9.50 9.50 9.50 0.95 - Opening 1 -- 9.50 12.50 3.00 3.00 - 2.00 Segment 2 -- 12.50 22.00 9.50 9.50 0.95 - Level 1 Line 11 Seg 1 53.50 0.00 52.00 52.00 22.00 - 9.00 Wall 11-1 Seg 1 53.50 0.00 22.00 22.00 22.00 0.41 - Line 12 Level 2 Line 12 2 57.50 22.00 52.00 30.00 9.00 - 9.00 Wall 12-1 Prf 2 57.50 22.00 35.00 13.00 9.00 - - Segment 1 -- 22.00 23.00 1.00 1.00 9.00 - Opening 1 -- 23.00 26.00 3.00 3.00 - 2.00 Segment 2 -- 26.00 35.00 9.00 9.00 1.00 - Level 1 Line 12 Seg 1 57.50 22.00 52.00 30.00 13.00 - 9.00 Wall 12-1 Seg 1 57.50 22.00 35.00 13.00 13.00 0.69 - Line 13 Level 2 Line 13 Prf 2 63.75 35.00 52.00 17.00 17.00 - 9.00 Wall 13-1 Prf 2 63.75 35.00 52.00 17.00 17.00 0.53 - Level 1 Line 13 Prf 2 63.75 35.00 52.00 17.00 17.00 - 9.00 Wall 13-1 Prf 2 63.75 35.00 52.00 17.00 17.00 0.53 - East-west Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group Y [ft] Start End [ft] [ft] Ratio [ft] Line A Level 2 Line A 2 0.00 29.75 53.50 23.75 0.00 - 9.00 Wall A-1 Prf 2 0.00 29.75 53.50 23.75 0.00 - - Segment 1 -- 29.75 31.50 1.75 1.75 5.14 - Opening 1 -- 31.50 40.50 9.00 9.00 - 8.00 Segment 2 -- 40.50 42.50 2.00 2.00 4.50 - Opening 2 -- 42.50 51.50 9.00 9.00 - 8.00 Segment 3 -- 51.50 53.50 2.00 2.00 4.50 - Level 1 Line A Seg 1 0.00 29.75 53.50 23.75 23.75 - 9.00 Wall A-1 Seg 1 0.00 29.75 53.50 23.75 23.75 0.38 - Line B Level 2 Line B 2 17.00 0.00 16.50 16.50 9.50 - 9.00 Wall B-1 Prf 2 17.00 0.00 16.50 16.50 9.50 - - Segment 1 -- 0.00 9.50 9.50 9.50 0.95 - Opening 1 -- 9.50 14.50 5.00 5.00 - 6.50 Segment 2 -- 14.50 16.50 2.00 2.00 4.50 - Level 1 Line B Seg 1 17.00 0.00 16.50 16.50 16.50 - 9.00 Wall B-1 Seg 1 17.00 0.00 16.50 16.50 16.50 0.55 - Line C Level 2 Line C 2 20.00 0.00 53.50 53.50 0.00 - 9.00 Wall C-1 Prf 2 20.00 16.50 29.75 13.25 0.00 - - Segment 1 -- 16.50 18.50 2.00 2.00 4.50 - Opening 1 -- 18.50 19.50 1.00 1.00 - 6.67 Segment 2 -- 19.50 21.50 2.00 2.00 4.50 - Opening 2 -- 21.50 24.50 3.00 3.00 - 6.67 5 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Segment 3 -- 24.50 26.25 1.75 1.75 5.14 - Opening 3 -- 26.25 27.75 1.50 1.50 - 5.00 Segment 4 -- 27.75 29.75 2.00 2.00 4.50 - Level 1 Line C Seg 1 20.00 0.00 53.50 53.50 13.25 - 9.00 Wall C-1 Seg 1 20.00 16.50 29.75 13.25 13.25 0.68 - Line D Level 2 Line D 2 22.21 0.00 57.50 57.50 23.56 - 9.00 Wall D-1 Prf 2 22.25 29.75 53.75 24.00 20.00 - - Segment 1 -- 29.75 49.75 20.00 20.00 0.45 - Opening 1 -- 49.75 52.75 3.00 3.00 - 6.67 Segment 2 -- 52.75 53.75 1.00 1.00 9.00 - Wall D-2 Prf 2 22.00 53.50 57.50 4.00 3.56 2.25 - Level 1 Line D 1 22.21 0.00 57.50 57.50 28.00 - 9.00 Wall D-1 Seg 1 22.25 29.75 53.75 24.00 24.00 0.38 - Wall D-2 Seg 1 22.00 53.50 57.50 4.00 4.00 2.25 - Line E Level 2 Line E 2 27.00 0.00 57.50 57.50 0.00 - 9.00 Wall E-1 Prf 2 27.00 0.00 4.50 4.50 0.00 - - Segment 1 -- 0.00 1.00 1.00 1.00 9.00 - Opening 1 -- 1.00 4.00 3.00 3.00 - 5.00 Segment 2 -- 4.00 4.50 0.50 0.50 18.00 - Wall E-2 NSW 26.50 21.50 42.50 21.00 0.00 1.00 - Level 1 Line E Seg 1 27.00 0.00 57.50 57.50 4.50 - 9.00 Wall E-1 Seg 1 27.00 0.00 4.50 4.50 4.50 2.00 - Line F Level 2 Line F Prf 2 32.00 4.50 57.50 53.00 21.50 - 9.00 Wall F-1 Prf 2 32.00 36.00 57.50 21.50 21.50 0.42 - Line G Level 2 Line G Seg 3 35.00 4.50 63.75 59.25 6.25 - 9.00 Wall G-1 Seg 3 35.00 57.50 63.75 6.25 6.25 1.44 - Level 1 Line G Seg 1 35.00 4.50 63.75 59.25 6.25 - 9.00 Wall G-1 Seg 1 35.00 57.50 63.75 6.25 6.25 1.44 - Line H Level 2 Line H 2 42.00 4.50 63.75 59.25 0.00 - 9.00 Wall H-1 Prf 2 42.00 4.50 19.50 15.00 0.00 - - Segment 1 -- 4.50 6.50 2.00 2.00 4.50 - Opening 1 -- 6.50 18.50 12.00 12.00 - 6.67 Segment 2 -- 18.50 19.50 1.00 1.00 9.00 - Level 1 Line H 2 42.00 4.50 63.75 59.25 0.00 - 9.00 Wall H-1 Prf 2 42.00 4.50 19.50 15.00 0.00 - - Segment 1 -- 4.50 5.50 1.00 1.00 9.00 - Opening 1 -- 5.50 8.50 3.00 3.00 - 5.00 Segment 2 -- 8.50 10.50 2.00 2.00 4.50 - Opening 2 -- 10.50 13.50 3.00 3.00 - 6.67 Segment 3 -- 13.50 15.50 2.00 2.00 4.50 - Opening 3 -- 15.50 18.50 3.00 3.00 - 5.00 Segment 4 -- 18.50 19.50 1.00 1.00 9.00 - Line I Level 2 Line I 2 46.00 19.50 63.75 44.25 0.00 - 9.00 Wall I-1 Prf 2 46.00 19.50 35.50 16.00 0.00 - - Segment 1 -- 19.50 21.25 1.75 1.75 5.14 - Opening 1 -- 21.25 24.25 3.00 3.00 - 5.00 Segment 2 -- 24.25 24.75 0.50 0.50 18.00 - Opening 2 -- 24.75 30.75 6.00 6.00 - 5.00 Segment 3 -- 30.75 31.25 0.50 0.50 18.00 - Opening 3 -- 31.25 34.25 3.00 3.00 - 5.00 Segment 4 -- 34.25 35.50 1.25 1.25 7.20 - Level 1 Line I 2 46.00 19.50 63.75 44.25 0.00 - 9.00 Wall I-1 Prf 2 46.00 19.50 35.50 16.00 0.00 - - Segment 1 -- 19.50 21.25 1.75 1.75 5.14 - 6 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Opening 1 -- 21.25 24.25 3.00 3.00 - 5.00 Segment 2 -- 24.25 24.75 0.50 0.50 18.00 - Opening 2 -- 24.75 30.75 6.00 6.00 - 2.50 Segment 3 -- 30.75 31.25 0.50 0.50 18.00 - Opening 3 -- 31.25 34.25 3.00 3.00 - 5.00 Segment 4 -- 34.25 35.50 1.25 1.25 7.20 - Line J Level 2 Line J 2 52.00 35.50 63.75 28.25 9.93 - 9.00 Wall J-1 Prf 2 52.00 35.50 63.75 28.25 9.93 - - Segment 1 -- 35.50 36.75 1.25 1.25 7.20 - Opening 1 -- 36.75 39.75 3.00 3.00 - 5.00 Segment 2 -- 39.75 40.25 0.50 0.50 18.00 - Opening 2 -- 40.25 46.25 6.00 6.00 - 5.00 Segment 3 -- 46.25 46.75 0.50 0.50 18.00 - Opening 3 -- 46.75 49.75 3.00 3.00 - 5.00 Segment 4 -- 49.75 58.00 8.25 8.25 1.09 - Opening 4 -- 58.00 61.00 3.00 3.00 - 3.50 Segment 5 -- 61.00 63.75 2.75 1.68 3.27 - Level 1 Line J 2 52.00 35.50 63.75 28.25 14.25 - 9.00 Wall J-1 Prf 2 52.00 35.50 63.75 28.25 14.25 - - Segment 1 -- 35.50 36.50 1.00 1.00 9.00 - Opening 1 -- 36.50 39.50 3.00 3.00 - 2.50 Segment 2 -- 39.50 40.25 0.75 0.75 12.00 - Opening 2 -- 40.25 46.25 6.00 6.00 - 2.50 Segment 3 -- 46.25 46.50 0.25 0.25 36.00 - Opening 3 -- 46.50 49.50 3.00 3.00 - 5.00 Segment 4 -- 49.50 63.75 14.25 14.25 0.63 - Legend: Type - Seg = segmented, Prf = perforated, FT = force-transfer, NSW = non-shearwall Location - Dimension perpendicular to wall FHS - Length of full-height sheathing used to resist shear force. For perforated walls, it is based on the factored segments Li defined in SDPWS 4.3.4.3 Aspect Ratio – Ratio of wall height to segment length (h/bs), for force-transfer walls, the aspect ratio of the central pier Wall Group - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall 7 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Loads WIND SHEAR LOADS (as entered or generated) Level 2 Magnitude Trib Block F Element Load Wnd Surf Prof Location [ft][lbs,plf,psf]Ht Case Dir Dir Start End Start End [ft] Block 1 W L Gable Min W->E Wind Line 17.00 52.00 0.0 34.4 Block 1 W L Gable 1 W->E Wind Line 17.00 52.00 0.0 85.6 Block 1 W Wall 1 W->E Wind Line 17.00 27.00 87.0 Block 1 W Wall Min W->E Wind Line 17.00 27.00 36.0 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 87.0 Block 1 W Wall Min W->E Wind Line 27.00 42.00 36.0 Block 1 W Wall Min W->E Wind Line 42.00 46.00 36.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 87.0 Block 1 W Wall Min W->E Wind Line 46.00 52.00 36.0 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 87.0 Block 1 E Wall Min W->E Lee Line 17.00 20.00 36.0 Block 1 E L Gable Min W->E Lee Line 17.00 52.00 0.0 34.4 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 37.8 Block 1 E L Gable 1 W->E Lee Line 17.00 52.00 0.0 36.1 Block 1 E Wall Min W->E Lee Line 35.00 52.00 36.0 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 37.8 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 37.8 Block 1 W L Gable Min E->W Lee Line 17.00 52.00 0.0 34.4 Block 1 W L Gable 1 E->W Lee Line 17.00 52.00 0.0 36.1 Block 1 W Wall Min E->W Lee Line 17.00 27.00 36.0 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 37.8 Block 1 W Wall Min E->W Lee Line 27.00 42.00 36.0 Block 1 W Wall Min E->W Lee Line 42.00 46.00 36.0 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 37.8 Block 1 W Wall Min E->W Lee Line 46.00 52.00 36.0 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 37.8 Block 1 E L Gable 1 E->W Wind Line 17.00 52.00 0.0 85.6 Block 1 E Wall Min E->W Wind Line 17.00 20.00 36.0 Block 1 E L Gable Min E->W Wind Line 17.00 52.00 0.0 34.4 Block 1 E Wall 1 E->W Wind Line 17.00 20.00 87.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 87.0 Block 1 E Wall Min E->W Wind Line 35.00 52.00 36.0 Block 1 S Roof Min S->N Wind Line -1.50 65.25 294.2 Block 1 S Wall Min S->N Wind Line 0.00 16.50 36.0 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 87.0 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 87.0 Block 1 S Wall Min S->N Wind Line 16.50 29.75 36.0 Block 1 N Roof 1 S->N Lee Line -1.50 65.25 64.6 Block 1 N Roof Min S->N Lee Line -1.50 65.25 17.2 Block 1 N Wall Min S->N Lee Line 0.00 4.50 36.0 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 56.4 Block 1 N Wall Min S->N Lee Line 4.50 19.50 36.0 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 56.4 Block 1 N Wall Min S->N Lee Line 19.50 35.50 36.0 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 56.4 Block 1 N Wall Min S->N Lee Line 35.50 63.75 36.0 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 56.4 Block 1 S Roof Min N->S Lee Line -1.50 65.25 294.2 Block 1 S Wall Min N->S Lee Line 0.00 16.50 36.0 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 55.5 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 55.5 Block 1 S Wall Min N->S Lee Line 16.50 29.75 36.0 Block 1 N Roof 1 N->S Wind Line -1.50 65.25 86.1 Block 1 N Roof Min N->S Wind Line -1.50 65.25 17.2 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 87.0 Block 1 N Wall Min N->S Wind Line 0.00 4.50 36.0 Block 1 N Wall Min N->S Wind Line 4.50 19.50 36.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 87.0 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 87.0 Block 1 N Wall Min N->S Wind Line 19.50 35.50 36.0 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 87.0 Block 1 N Wall Min N->S Wind Line 35.50 63.75 36.0 Block 2 W Wall 1 W->E Wind Line 0.00 20.00 87.0 Block 2 W L Gable Min W->E Wind Line 0.00 17.00 0.0 16.7 Block 2 W Wall Min W->E Wind Line 0.00 20.00 36.0 Block 2 W L Gable 1 W->E Wind Line 0.00 17.00 0.0 41.4 Block 2 E L Gable 1 W->E Lee Line 0.00 17.00 0.0 19.4 Block 2 E L Gable Min W->E Lee Line 0.00 17.00 0.0 16.7 8 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 WIND SHEAR LOADS (as entered or generated) (continued) Block 2 E Wall 1 W->E Lee Line 0.00 22.00 41.8 Block 2 E Wall Min W->E Lee Line 0.00 22.00 36.0 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 41.8 Block 2 E Wall Min W->E Lee Line 22.00 35.00 36.0 Block 2 W Wall 1 E->W Lee Line 0.00 20.00 41.8 Block 2 W Wall Min E->W Lee Line 0.00 20.00 36.0 Block 2 W L Gable 1 E->W Lee Line 0.00 17.00 0.0 19.4 Block 2 W L Gable Min E->W Lee Line 0.00 17.00 0.0 16.7 Block 2 E L Gable 1 E->W Wind Line 0.00 17.00 0.0 41.4 Block 2 E L Gable Min E->W Wind Line 0.00 17.00 0.0 16.7 Block 2 E Wall 1 E->W Wind Line 0.00 22.00 87.0 Block 2 E Wall Min E->W Wind Line 0.00 22.00 36.0 Block 2 E Wall Min E->W Wind Line 22.00 35.00 36.0 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 87.0 Block 2 S Roof Min S->N Wind Line 28.25 59.00 149.1 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 87.0 Block 2 S Wall Min S->N Wind Line 29.75 53.50 36.0 Block 2 S Wall Min S->N Wind Line 53.50 57.50 36.0 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 87.0 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 87.0 Block 2 S Wall Min S->N Wind Line 57.50 63.75 36.0 Block 2 N Roof 1 S->N Lee Line 28.25 59.00 31.1 Block 2 N Roof Min S->N Lee Line 28.25 59.00 8.3 Block 2 S Roof Min N->S Lee Line 28.25 59.00 149.1 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 55.5 Block 2 S Wall Min N->S Lee Line 29.75 53.50 36.0 Block 2 S Wall Min N->S Lee Line 53.50 57.50 36.0 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 55.5 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 55.5 Block 2 S Wall Min N->S Lee Line 57.50 63.75 36.0 Block 2 N Roof Min N->S Wind Line 28.25 59.00 8.3 Block 2 N Roof 1 N->S Wind Line 28.25 59.00 41.5 Level 1 Magnitude Trib Block F Element Load Wnd Surf Prof Location [ft][lbs,plf,psf]Ht Case Dir Dir Start End Start End [ft] Block 1 W Wall 1 W->E Wind Line 17.00 27.00 83.6 Block 1 W Wall 1 W->E Wind Line 17.00 27.00 101.4 Block 1 W Wall Min W->E Wind Line 17.00 27.00 36.0 Block 1 W Wall Min W->E Wind Line 17.00 27.00 44.0 Block 1 W Wall Min W->E Wind Line 27.00 42.00 36.0 Block 1 W Wall Min W->E Wind Line 27.00 42.00 44.0 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 83.6 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 101.4 Block 1 W Wall Min W->E Wind Line 42.00 46.00 44.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 83.6 Block 1 W Wall Min W->E Wind Line 42.00 46.00 36.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 101.4 Block 1 W Wall Min W->E Wind Line 46.00 52.00 36.0 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 101.4 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 83.6 Block 1 W Wall Min W->E Wind Line 46.00 52.00 44.0 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 46.2 Block 1 E Wall Min W->E Lee Line 17.00 20.00 44.0 Block 1 E Wall Min W->E Lee Line 17.00 20.00 36.0 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 37.8 Block 1 E Wall Min W->E Lee Line 35.00 52.00 44.0 Block 1 E Wall Min W->E Lee Line 35.00 52.00 36.0 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 46.2 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 37.8 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 46.2 Block 1 W Wall Min E->W Lee Line 17.00 27.00 36.0 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 37.8 Block 1 W Wall Min E->W Lee Line 17.00 27.00 44.0 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 37.8 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 46.2 Block 1 W Wall Min E->W Lee Line 27.00 42.00 44.0 Block 1 W Wall Min E->W Lee Line 27.00 42.00 36.0 Block 1 W Wall Min E->W Lee Line 42.00 46.00 36.0 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 46.2 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 37.8 Block 1 W Wall Min E->W Lee Line 42.00 46.00 44.0 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 46.2 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 37.8 9 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 WIND SHEAR LOADS (as entered or generated) (continued) Block 1 W Wall Min E->W Lee Line 46.00 52.00 44.0 Block 1 W Wall Min E->W Lee Line 46.00 52.00 36.0 Block 1 E Wall 1 E->W Wind Line 17.00 20.00 101.4 Block 1 E Wall 1 E->W Wind Line 17.00 20.00 83.6 Block 1 E Wall Min E->W Wind Line 17.00 20.00 36.0 Block 1 E Wall Min E->W Wind Line 17.00 20.00 44.0 Block 1 E Wall Min E->W Wind Line 35.00 52.00 44.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 83.6 Block 1 E Wall Min E->W Wind Line 35.00 52.00 36.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 101.4 Block 1 S Wall Min S->N Wind Line 0.00 16.50 36.0 Block 1 S Wall Min S->N Wind Line 0.00 16.50 44.0 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 101.4 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 83.6 Block 1 S Wall Min S->N Wind Line 16.50 29.75 36.0 Block 1 S Wall Min S->N Wind Line 16.50 29.75 44.0 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 83.6 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 101.4 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 68.9 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 56.4 Block 1 N Wall Min S->N Lee Line 0.00 4.50 44.0 Block 1 N Wall Min S->N Lee Line 0.00 4.50 36.0 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 68.9 Block 1 N Wall Min S->N Lee Line 4.50 19.50 36.0 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 56.4 Block 1 N Wall Min S->N Lee Line 4.50 19.50 44.0 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 56.4 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 68.9 Block 1 N Wall Min S->N Lee Line 19.50 35.50 36.0 Block 1 N Wall Min S->N Lee Line 19.50 35.50 44.0 Block 1 N Wall Min S->N Lee Line 35.50 63.75 44.0 Block 1 N Wall Min S->N Lee Line 35.50 63.75 36.0 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 56.4 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 68.9 Block 1 S Wall Min N->S Lee Line 0.00 16.50 44.0 Block 1 S Wall Min N->S Lee Line 0.00 16.50 36.0 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 67.8 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 55.5 Block 1 S Wall Min N->S Lee Line 16.50 29.75 44.0 Block 1 S Wall Min N->S Lee Line 16.50 29.75 36.0 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 67.8 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 55.5 Block 1 N Wall Min N->S Wind Line 0.00 4.50 36.0 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 83.6 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 101.4 Block 1 N Wall Min N->S Wind Line 0.00 4.50 44.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 101.4 Block 1 N Wall Min N->S Wind Line 4.50 19.50 36.0 Block 1 N Wall Min N->S Wind Line 4.50 19.50 44.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 83.6 Block 1 N Wall Min N->S Wind Line 19.50 35.50 36.0 Block 1 N Wall Min N->S Wind Line 19.50 35.50 44.0 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 101.4 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 83.6 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 83.6 Block 1 N Wall Min N->S Wind Line 35.50 63.75 44.0 Block 1 N Wall Min N->S Wind Line 35.50 63.75 36.0 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 101.4 Block 2 W Wall 1 W->E Wind Line 0.00 20.00 83.6 Block 2 W Wall 1 W->E Wind Line 0.00 20.00 101.4 Block 2 W Wall Min W->E Wind Line 0.00 20.00 44.0 Block 2 W Wall Min W->E Wind Line 0.00 20.00 36.0 Block 2 E Wall Min W->E Lee Line 0.00 22.00 44.0 Block 2 E Wall 1 W->E Lee Line 0.00 22.00 41.8 Block 2 E Wall 1 W->E Lee Line 0.00 22.00 51.0 Block 2 E Wall Min W->E Lee Line 0.00 22.00 36.0 Block 2 E Wall Min W->E Lee Line 22.00 35.00 36.0 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 51.0 Block 2 E Wall Min W->E Lee Line 22.00 35.00 44.0 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 41.8 Block 2 W Wall 1 E->W Lee Line 0.00 20.00 41.8 Block 2 W Wall 1 E->W Lee Line 0.00 20.00 51.0 Block 2 W Wall Min E->W Lee Line 0.00 20.00 36.0 10 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 WIND SHEAR LOADS (as entered or generated) (continued) Block 2 W Wall Min E->W Lee Line 0.00 20.00 44.0 Block 2 E Wall 1 E->W Wind Line 0.00 22.00 101.4 Block 2 E Wall 1 E->W Wind Line 0.00 22.00 83.6 Block 2 E Wall Min E->W Wind Line 0.00 22.00 44.0 Block 2 E Wall Min E->W Wind Line 0.00 22.00 36.0 Block 2 E Wall Min E->W Wind Line 22.00 35.00 36.0 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 101.4 Block 2 E Wall Min E->W Wind Line 22.00 35.00 44.0 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 83.6 Block 2 S Wall Min S->N Wind Line 29.75 53.50 44.0 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 101.4 Block 2 S Wall Min S->N Wind Line 29.75 53.50 36.0 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 83.6 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 83.6 Block 2 S Wall Min S->N Wind Line 53.50 57.50 44.0 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 101.4 Block 2 S Wall Min S->N Wind Line 53.50 57.50 36.0 Block 2 S Wall Min S->N Wind Line 57.50 63.75 44.0 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 101.4 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 83.6 Block 2 S Wall Min S->N Wind Line 57.50 63.75 36.0 Block 2 S Wall Min N->S Lee Line 29.75 53.50 36.0 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 67.8 Block 2 S Wall Min N->S Lee Line 29.75 53.50 44.0 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 55.5 Block 2 S Wall Min N->S Lee Line 53.50 57.50 44.0 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 67.8 Block 2 S Wall Min N->S Lee Line 53.50 57.50 36.0 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 55.5 Block 2 S Wall Min N->S Lee Line 57.50 63.75 36.0 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 55.5 Block 2 S Wall Min N->S Lee Line 57.50 63.75 44.0 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 67.8 Legend: Block - Block used in load generation Accum. = loads from one block combined with another Manual = user-entered loads (so no block) F - Building face (north, south, east or west) Element - Building surface on which loads generated or entered Load Case - One of the following: ASCE 7 All Heights: Case 1 or 2 from Fig 27.3-8 or minimum loads from 27.1.5 ASCE 7 Low-rise: Reference corner and Case A or B from Fig 28.3-1 or minimum loads from 28.3.4 Wind Dir - Direction of wind for loads with positive magnitude, also direction of MWFRS. Surf Dir - Windward or leeward side of the building for loads in given direction Prof - Profile (distribution) Location - Start and end points on building element Magnitude - Start = intensity of uniform and point loads or leftmost intensity of trapezoidal load, End = right intensity of trap load Trib Ht - Tributary height of area loads only Notes: Windward load on the monoslope roof was not generated, to comply with ASCE 7 Figure 27.3-1, Note 7. All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.60 to wind loads before distributing them to the shearlines. 11 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 BUILDING MASSES Level 2 Magnitude Trib Force Building Block Wall Profile Location [ft][lbs,plf,psf]Width Dir Element Line Start End Start End [ft] E-W Roof Block 1 1 Line 15.50 53.50 500.6 500.6 E-W Roof Block 1 13 Line 15.50 53.50 500.6 500.6 E-W Roof Block 2 7 Line -1.50 18.50 230.6 230.6 E-W Roof Block 2 12 Line -1.50 18.50 230.6 230.6 E-W R Gable Block 1 1 Line 17.00 52.00 43.0 0.0 E-W L Gable Block 1 1 Line 52.00 52.00 0.0 43.0 E-W L Gable Block 1 13 Line 17.00 52.00 43.0 0.0 E-W R Gable Block 1 13 Line 52.00 52.00 0.0 43.0 E-W R Gable Block 2 7 Line 0.00 17.00 20.9 0.0 E-W L Gable Block 2 7 Line 17.00 17.00 0.0 20.9 E-W L Gable Block 2 12 Line 0.00 17.00 20.9 0.0 E-W R Gable Block 2 12 Line 17.00 17.00 0.0 20.9 N-S Roof Block 1 B Line -1.50 65.25 285.0 285.0 N-S Roof Block 1 J Line -1.50 65.25 285.0 285.0 N-S Roof Block 2 A Line 28.25 59.00 150.0 150.0 N-S Roof Block 2 B Line 28.25 59.00 150.0 150.0 Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 Both Wall 3-1 n/a Line 17.00 26.50 27.0 27.0 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 Both Wall 7-1 n/a 7 Line 0.00 20.00 45.0 45.0 Both Wall 7-2 n/a 7 Line 20.00 22.00 27.0 27.0 Both Wall 8-1 n/a 8 Line 46.00 52.00 45.0 45.0 Both Wall 9-1 n/a 9 Line 32.00 42.25 27.0 27.0 Both Wall 10-1 n/a 10 Line 32.00 40.00 27.0 27.0 Both Wall 10-2 n/a 10 Line 43.00 52.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 0.00 22.00 45.0 45.0 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 Both Wall A-1 n/a A Line 29.75 53.50 45.0 45.0 Both Wall B-1 n/a B Line 0.00 16.50 45.0 45.0 Both Wall C-1 n/a C Line 16.50 29.75 45.0 45.0 Both Wall D-2 n/a D Line 53.50 57.50 45.0 45.0 Both Wall D-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall E-2 n/a Line 21.50 42.50 27.0 27.0 Both Wall E-1 n/a E Line 0.00 4.50 45.0 45.0 Both Wall F-1 n/a F Line 36.00 57.50 27.0 27.0 Both Wall G-1 n/a G Line 57.50 63.75 45.0 45.0 Both Wall H-1 n/a H Line 4.50 19.50 45.0 45.0 Both Wall I-1 n/a I Line 19.50 35.50 45.0 45.0 Both Wall J-1 n/a J Line 35.50 63.75 45.0 45.0 Level 1 Magnitude Trib Force Building Block Wall Profile Location [ft][lbs,plf,psf]Width Dir Element Line Start End Start End [ft] E-W Floor F8 n/a 1 Line 17.00 20.00 82.5 82.5 Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 E-W Floor F2 n/a 1 Line 20.00 22.00 267.5 267.5 E-W Floor F3 n/a 1 Line 22.00 27.00 287.5 287.5 E-W Floor F4 n/a 2 Line 27.00 35.00 265.0 265.0 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 E-W Floor F5 n/a 2 Line 35.00 42.00 296.3 296.3 Both Wall 3-1 n/a Line 17.00 26.50 27.0 27.0 E-W Floor F8 n/a 4 Line 17.00 20.00 82.5 82.5 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 E-W Floor F6 n/a 5 Line 42.00 46.00 221.3 221.3 12 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 BUILDING MASSES (continued) Both Wall 7-1 n/a 7 Line 0.00 20.00 45.0 45.0 E-W Floor F1 n/a 7 Line 0.00 20.00 118.8 118.8 Both Wall 7-2 n/a 7 Line 20.00 22.00 27.0 27.0 Both Wall 8-1 n/a 8 Line 46.00 52.00 45.0 45.0 E-W Floor F7 n/a 8 Line 46.00 52.00 141.3 141.3 Both Wall 9-1 n/a 9 Line 32.00 42.25 27.0 27.0 Both Wall 10-1 n/a 10 Line 32.00 40.00 27.0 27.0 Both Wall 10-2 n/a 10 Line 43.00 52.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 0.00 22.00 45.0 45.0 E-W Floor F1 n/a 11 Line 0.00 20.00 118.8 118.8 E-W Floor F2 n/a 11 Line 20.00 22.00 267.5 267.5 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 E-W Floor F3 n/a 12 Line 22.00 27.00 287.5 287.5 E-W Floor F4 n/a 12 Line 27.00 35.00 265.0 265.0 Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 E-W Floor F5 n/a 13 Line 35.00 42.00 296.3 296.3 E-W Floor F6 n/a 13 Line 42.00 46.00 221.3 221.3 E-W Floor F7 n/a 13 Line 46.00 52.00 141.3 141.3 N-S Floor F5 n/a A Line 29.75 35.50 230.0 230.0 Both Wall A-1 n/a A Line 29.75 53.50 45.0 45.0 N-S Floor F6 n/a A Line 35.50 53.50 260.0 260.0 Both Wall B-1 n/a B Line 0.00 16.50 45.0 45.0 N-S Floor F1 n/a B Line 0.00 4.50 50.0 50.0 N-S Floor F2 n/a B Line 4.50 16.50 125.0 125.0 Both Wall C-1 n/a C Line 16.50 29.75 45.0 45.0 N-S Floor F3 n/a C Line 16.50 19.50 110.0 110.0 N-S Floor F4 n/a C Line 19.50 29.75 130.0 130.0 Both Wall D-2 n/a D Line 53.50 57.50 45.0 45.0 N-S Floor F7 n/a D Line 53.50 57.50 150.0 150.0 Both Wall D-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall E-2 n/a Line 21.50 42.50 27.0 27.0 Both Wall E-1 n/a E Line 0.00 4.50 45.0 45.0 N-S Floor F1 n/a E Line 0.00 4.50 50.0 50.0 Both Wall F-1 n/a F Line 36.00 57.50 27.0 27.0 Both Wall G-1 n/a G Line 57.50 63.75 45.0 45.0 N-S Floor F8 n/a G Line 57.50 63.75 85.0 85.0 N-S Floor F2 n/a H Line 4.50 16.50 125.0 125.0 Both Wall H-1 n/a H Line 4.50 19.50 45.0 45.0 N-S Floor F3 n/a H Line 16.50 19.50 110.0 110.0 N-S Floor F4 n/a I Line 19.50 29.75 130.0 130.0 Both Wall I-1 n/a I Line 19.50 35.50 45.0 45.0 N-S Floor F5 n/a I Line 29.75 35.50 230.0 230.0 Both Wall J-1 n/a J Line 35.50 63.75 45.0 45.0 N-S Floor F6 n/a J Line 35.50 53.50 260.0 260.0 N-S Floor F7 n/a J Line 53.50 57.50 150.0 150.0 N-S Floor F8 n/a J Line 57.50 63.75 85.0 85.0 13 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 BUILDING MASSES (continued) Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 Both Wall 3-1 n/a 3 Line 17.00 27.25 27.0 27.0 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 Both Wall 6-1 n/a 6 Line 32.50 40.50 27.0 27.0 Both Wall 7-1 n/a 7 Line 0.00 20.00 45.0 45.0 Both Wall 7-2 n/a 7 Line 20.00 22.00 27.0 27.0 Both Wall 8-2 n/a 8 Line 46.00 52.00 45.0 45.0 Both Wall 8-1 n/a Line 26.75 46.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 0.00 22.00 45.0 45.0 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 Both Wall A-1 n/a A Line 29.75 53.50 45.0 45.0 Both Wall B-1 n/a B Line 0.00 16.50 45.0 45.0 Both Wall C-1 n/a C Line 16.50 29.75 45.0 45.0 Both Wall D-2 n/a D Line 53.50 57.50 45.0 45.0 Both Wall D-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall E-1 n/a E Line 0.00 4.50 45.0 45.0 Both Wall G-1 n/a G Line 57.50 63.75 45.0 45.0 Both Wall H-1 n/a H Line 4.50 19.50 45.0 45.0 Both Wall I-1 n/a I Line 19.50 35.50 45.0 45.0 Both Wall J-1 n/a J Line 35.50 63.75 45.0 45.0 Legend: Force Dir - Direction in which the mass is used for seismic load generation, E-W, N-S, or Both Building element - Roof, gable end, wall or floor area used to generate mass, wall line for user-applied masses, Floor F# - refer to Plan View for floor area number Wall line - Shearline that equivalent line load is assigned to Location - Start and end points of equivalent line load on wall line Trib Width. - Tributary width; for user applied area loads only 14 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SEISMIC LOADS Level 2 Force Profile Location [ft]Mag [lbs,plf,psf] Dir Start End Start End E-W Line -1.50 0.00 95.0 95.0 E-W Point 0.00 0.00 220 220 E-W Line 0.00 15.50 113.5 121.3 E-W Line 15.50 17.00 327.5 328.2 E-W Point 17.00 17.00 153 153 E-W Line 17.00 18.50 352.3 344.5 E-W Line 18.50 20.00 249.5 250.3 E-W Point 20.00 20.00 123 123 E-W Line 20.00 22.00 237.3 238.3 E-W Point 22.00 22.00 37 37 E-W Line 22.00 26.50 232.8 235.0 E-W Point 22.25 22.25 133 133 E-W Point 26.50 26.50 117 117 E-W Line 26.50 27.00 229.5 229.7 E-W Point 27.00 27.00 42 42 E-W Line 27.00 32.00 229.7 232.3 E-W Point 32.00 32.00 120 120 E-W Line 32.00 35.00 243.4 244.9 E-W Point 35.00 35.00 58 58 E-W Line 35.00 40.00 244.9 247.4 E-W Line 40.00 42.00 241.9 242.9 E-W Point 42.00 42.00 139 139 E-W Line 42.00 42.25 242.9 243.0 E-W Line 42.25 43.00 237.4 237.8 E-W Line 43.00 46.00 243.4 244.9 E-W Point 46.00 46.00 148 148 E-W Line 46.00 52.00 244.9 247.9 E-W Point 52.00 52.00 262 262 E-W Line 52.00 53.50 223.8 206.1 N-S Line -1.50 0.00 117.4 117.4 N-S Point 0.00 0.00 247 247 N-S Line 0.00 4.50 135.9 135.9 N-S Point 4.50 4.50 139 139 N-S Line 4.50 16.50 135.9 135.9 N-S Point 8.50 8.50 53 53 N-S Point 16.50 16.50 28 28 N-S Line 16.50 19.50 135.9 135.9 N-S Point 19.50 19.50 37 37 N-S Line 19.50 21.50 135.9 135.9 N-S Line 21.50 28.25 141.4 141.4 N-S Line 28.25 29.75 203.2 203.2 N-S Point 29.75 29.75 233 233 N-S Line 29.75 35.50 208.8 208.8 N-S Point 35.50 35.50 56 56 N-S Line 35.50 36.00 208.8 208.8 N-S Line 36.00 42.50 214.3 214.3 N-S Point 38.00 38.00 57 57 N-S Line 42.50 53.50 208.8 208.8 N-S Point 50.25 50.25 95 95 N-S Point 53.50 53.50 204 204 N-S Line 53.50 53.75 208.8 208.8 N-S Line 53.75 57.50 203.2 203.2 N-S Point 57.50 57.50 157 157 N-S Line 57.50 59.00 197.7 197.7 N-S Line 59.00 63.75 135.9 135.9 N-S Point 63.75 63.75 312 312 N-S Line 63.75 65.25 117.4 117.4 Level 1 Force Profile Location [ft]Mag [lbs,plf,psf] Dir Start End Start End E-W Point 0.00 0.00 232 232 E-W Line 0.00 17.00 45.2 45.2 E-W Point 17.00 17.00 161 161 E-W Line 17.00 20.00 88.5 88.5 E-W Point 20.00 20.00 129 129 E-W Line 20.00 22.00 89.2 89.2 E-W Point 22.00 22.00 39 39 E-W Line 22.00 26.50 87.7 87.7 15 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SEISMIC LOADS (continued) E-W Point 22.25 22.25 140 140 E-W Point 26.50 26.50 61 61 E-W Line 26.50 26.75 84.7 84.7 E-W Line 26.75 27.00 87.7 87.7 E-W Point 27.00 27.00 44 44 E-W Line 27.00 27.25 82.8 82.8 E-W Line 27.25 32.00 79.9 79.9 E-W Point 32.00 32.00 5038 5038 E-W Point 32.00 32.00 1691 1691 E-W Point 32.00 32.00 5038 5038 E-W Point 32.00 32.00 63 63 E-W Line 32.00 32.50 85.7 85.7 E-W Line 32.50 35.00 88.6 88.6 E-W Point 35.00 35.00 61 61 E-W Line 35.00 40.00 95.4 95.4 E-W Line 40.00 40.50 92.5 92.5 E-W Line 40.50 42.00 89.6 89.6 E-W Point 42.00 42.00 146 146 E-W Line 42.00 42.25 73.3 73.3 E-W Line 42.25 43.00 70.4 70.4 E-W Line 43.00 46.00 73.3 73.3 E-W Point 46.00 46.00 156 156 E-W Line 46.00 52.00 53.0 53.0 E-W Point 52.00 52.00 276 276 N-S Point 0.00 0.00 98 98 N-S Line 0.00 4.50 30.3 30.3 N-S Point 4.50 4.50 146 146 N-S Line 4.50 16.50 46.6 46.6 N-S Point 7.75 7.75 30 30 N-S Point 8.50 8.50 28 28 N-S Point 16.50 16.50 29 29 N-S Line 16.50 19.50 43.3 43.3 N-S Point 19.50 19.50 39 39 N-S Line 19.50 21.50 47.7 47.7 N-S Line 21.50 29.75 50.6 50.6 N-S Point 22.25 22.25 23 23 N-S Point 29.75 29.75 207 207 N-S Line 29.75 35.50 78.1 78.1 N-S Point 35.50 35.50 59 59 N-S Line 35.50 36.00 84.6 84.6 N-S Point 35.75 35.75 56 56 N-S Line 36.00 42.50 87.6 87.6 N-S Point 38.00 38.00 30 30 N-S Line 42.50 53.50 84.6 84.6 N-S Point 50.25 50.25 50 50 N-S Point 53.50 53.50 215 215 N-S Line 53.50 53.75 60.8 60.8 N-S Line 53.75 57.50 54.9 54.9 N-S Point 57.50 57.50 127 127 N-S Line 57.50 63.75 37.9 37.9 N-S Point 63.75 63.75 166 166 Legend: Loads in table can be accumulation of loads from several building masses, so they do not correspond with a particular building element. Location - Start and end of load in direction perpendicular to seismic force direction Notes: All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.70 and redundancy factor to seismic loads before distributing them to the shearlines. 16 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Design Summary SHEARWALL DESIGN Wind Shear Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. Wind Shear Loads, Rigid Diaphragm All shearwalls have sufficient design capacity. Components and Cladding Wind Loads, Out-of-plane Sheathing All shearwalls have sufficient design capacity. Components and Cladding Wind Loads, Nail Withdrawal All shearwalls have sufficient design capacity. Seismic Loads, Flexible Diaphragm All shearwalls have sufficient design capacity. Seismic Loads, Rigid Diaphragm All shearwalls have sufficient design capacity. HOLDDOWN DESIGN Wind Loads, Flexible Diaphragm Under-capacity hold-downs were found on the following walls: Level 1: G-1, 4-1, 7-1 Level 2: 4-1 Wind Loads, Rigid Diaphragm All hold-downs have sufficient design capacity. Seismic Loads, Flexible Diaphragm Under-capacity hold-downs were found on the following walls: Level 1: G-1, 4-1 Seismic Loads, Rigid Diaphragm All hold-downs have sufficient design capacity. Refer to the Deflection table for possible issues regarding fastener slippage (SDPWS Table C4.2.2D) for walls that otherwise pass. 17 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 209.6 209.6 1258 - 1.0 - 532 1.00 532 3192 0.39 Level 1 Ln1, Lev1 1 Both 147.4 - 1474 1.0 1.0 896 896 - A 1792 17920 0.08 Line 2 Ln2, Lev1 2 S->N 48.1 48.1 722 - 1.0 - 532 1.00 532 7980 0.09 2 N->S 47.8 47.8 717 - 1.0 - 532 1.00 532 7980 0.09 Line 3 Level 2 Ln3, Lev2 2 Both 199.8 199.8 1898 - 1.0 - 532 1.00 532 5054 0.38 Level 1 Ln3, Lev1 2 Both 241.3 241.3 2474 - 1.0 - 532 1.00 532 5453 0.45 Line 4 Level 2 Ln4, Lev2 - Both - - 2452 - - - - - - 2683 - Wall 4-1 4^Both 817.4 - 2452 - .88 - 1022 - 894 2683 0.91 Level 1 Ln4, Lev1 - Both - - 3016 - - - - - - 4704 - Wall 4-1 1^Both 1005.4 - 3016 .88 .88 896 896 - A 1568 4704 0.64 Line 5 Ln5, Lev1 2 S->N 308.4 308.4 1234 - 1.0 - 532 1.00 532 1892 0.58 2 N->S 306.4 306.4 1226 - 1.0 - 532 1.00 532 1892 0.58 Line 7 Level 2 Ln7, Lev2 - Both - - 5511 - - - - - - 9044 - Wall 7-1 2 Both 324.2 324.2 5511 - 1.0 - 532 1.00 532 9044 0.61 Wall 7-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 - - Level 1 Ln7, Lev1 - Both - - 6288 - - - - - - 35840 - Wall 7-1 1 Both 314.4 - 6288 1.0 1.0 896 896 - A 1792 35840 0.18 Wall 7-2 1 Both 0.0 - 0 1.0 1.0 896 896 - A - - - Line 8 Ln8, Lev1 - S->N - - 2211 - - - - - - 13433 - - N->S - - 2197 - - - - - - 13433 - Wall 8-1 2 S->N 114.9 114.9 2211 - 1.0 - 532 1.00 532 10241 0.22 2 N->S 114.1 114.1 2197 - 1.0 - 532 1.00 532 10241 0.21 Wall 8-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 3192 0.00 Line 11 Level 2 Ln11, Lev2 2 Both 237.0 237.0 4503 - 1.0 - 532 1.00 532 10108 0.45 Level 1 Ln11, Lev1 - Both - - 5549 - - - - - - 39424 - Wall 11-1 1 Both 252.2 - 5549 1.0 1.0 896 896 - A 1792 39424 0.14 Line 12 Level 2 Ln12, Lev2 2 Both 165.8 165.8 1493 - 1.0 - 532 1.00 532 4788 0.31 Level 1 Ln12, Lev1 - Both - - 1985 - - - - - - 23296 - Wall 12-1 1 Both 152.7 - 1985 1.0 1.0 896 896 - A 1792 23296 0.09 Line 13 Level 2 Ln13, Lev2 2 Both 59.8 59.8 1016 - 1.0 - 532 1.00 532 9044 0.11 Level 1 Ln13, Lev1 2 Both 77.4 77.4 1316 - 1.0 - 532 1.00 532 9044 0.15 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 1 Both 59.7 - 1417 1.0 1.0 896 896 - A 1792 42560 0.03 Line B Level 2 LnB, Lev2 2 W->E 210.0 210.0 1995 - 1.0 - 532 1.00 532 5054 0.39 2 E->W 209.8 209.8 1994 - 1.0 - 532 1.00 532 5054 0.39 Level 1 18 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (flexible wind design, continued) LnB, Lev1 1 W->E 236.6 - 3904 1.0 1.0 896 896 - A 1792 29568 0.13 1 E->W 236.6 - 3903 1.0 1.0 896 896 - A 1792 29568 0.13 Line C LnC, Lev1 - W->E - - 677 - - - - - - 23744 - - E->W - - 671 - - - - - - 23744 - Wall C-1 1 W->E 51.1 - 677 1.0 1.0 896 896 - A 1792 23744 0.03 1 E->W 50.7 - 671 1.0 1.0 896 896 - A 1792 23744 0.03 Line D Level 2 LnD, Lev2 - W->E - - 750 - - - - - - 12532 - - E->W - - 734 - - - - - - 12532 - Wall D-1 2 W->E 37.5 37.5 750 - 1.0 - 532 1.00 532 10640 0.07 2 E->W 36.7 36.7 734 - 1.0 - 532 1.00 532 10640 0.07 Wall D-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 1892 0.00 Level 1 LnD, Lev1 - W->E - - 1333 - - - - - - 49952 - - E->W - - 1299 - - - - - - 49952 - Wall D-1 1 W->E 43.9 - 1054 1.0 1.0 896 896 - A 1792 43008 0.02 1 E->W 54.1 - 1299 1.0 1.0 896 896 - A 1792 43008 0.03 Wall D-2 1 W->E 69.9 - 280 .97 .97 896 896 - A 1736 6944 0.04 1 E->W 0.0 - 0 .97 .97 896 896 - A 1736 6944 0.00 Line E LnE, Lev1 - W->E - - 1315 - - - - - - 8064 - - E->W - - 1276 - - - - - - 8064 - Wall E-1 1 W->E 292.2 - 1315 1.0 1.0 896 896 - A 1792 8064 0.16 1 E->W 283.5 - 1276 1.0 1.0 896 896 - A 1792 8064 0.16 Line F Level 2 LnF, Lev2 2 W->E 30.9 30.9 664 - 1.0 - 532 1.00 532 11438 0.06 2 E->W 30.2 30.2 649 - 1.0 - 532 1.00 532 11438 0.06 Line G LnG, Lev2 - W->E - - 1226 - - - - - - 4288 - - E->W - - 1222 - - - - - - 4288 - Wall G-1 3 W->E 196.2 - 1226 - 1.0 - 686 - 686 4288 0.29 3 E->W 195.6 - 1222 - 1.0 - 686 - 686 4288 0.29 Level 1 LnG, Lev1 - W->E - - 3681 - - - - - - 11200 - - E->W - - 3647 - - - - - - 11200 - Wall G-1 1 W->E 588.9 - 3681 1.0 1.0 896 896 - A 1792 11200 0.33 1 E->W 583.5 - 3647 1.0 1.0 896 896 - A 1792 11200 0.33 Line J Level 2 LnJ, Lev2 2 Both 105.2 105.2 1157 - 1.0 - 532 1.00 532 5283 0.20 Level 1 LnJ, Lev1 2 Both 177.6 177.6 2530 - 1.0 - 532 1.00 532 7581 0.33 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 19 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (flexible wind design) Level 1 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 3464 3464 HDU5-SDS2. 5645 0.61 V Elem 0.00 22.88 Min 2103 2103 Refer to upper level 1-1 R End 0.00 26.88 Min 1360 1360 HDU5-SDS2. 5645 0.24 Line 2 2-1 L End 4.50 27.13 1 440 440 HDU5-SDS2. 5645 0.08 2-1 R End 4.50 41.88 1 437 437 HDU5-SDS2. 5645 0.08 Line 3 3-1 L End 7.75 17.13 Min 4073 4073 HDU5-SDS2. 5645 0.72 V Elem 8.50 26.38 Min 1846 1846 Refer to upper level 3-1 R End 7.75 27.13 Min 2226 2226 HDU5-SDS2. 5645 0.39 Line 4 4-1 L End 16.50 17.13 Min 17896 17896 HDU5-SDS2. 5645 3.17* 4-1 R End 16.50 19.88 Min 17896 17896 HDU5-SDS2. 5645 3.17* Line 5 5-1 L End 19.50 42.13 1 3331 3331 HDU5-SDS2. 5645 0.59 5-1 R End 19.50 45.88 1 3309 3309 HDU5-SDS2. 5645 0.59 Line 7 7-1 L End 29.75 0.12 Min 6122 6122 HDU5-SDS2. 5645 1.08* 7-1 R End 29.75 19.88 Min 6122 6122 HDU5-SDS2. 5645 1.08* Line 8 8-1 L End 35.75 26.88 1 1047 1047 HDU5-SDS2. 5645 0.19 8-1 R End 35.75 45.88 1 1041 1041 HDU5-SDS2. 5645 0.18 Line 11 11-1 L End 53.50 0.12 Min 4458 4458 HDU5-SDS2. 5645 0.79 11-1 R End 53.50 21.88 Min 4458 4458 HDU5-SDS2. 5645 0.79 Line 12 12-1 L End 57.50 22.13 Min 1401 1401 HDU5-SDS2. 5645 0.25 V Elem 57.50 26.13 Min 1535 1535 Refer to upper level 12-1 R End 57.50 34.88 Min 2936 2936 HDU5-SDS2. 5645 0.52 Line 13 13-1 L End 63.75 35.12 Min 1450 1450 HDU5-SDS2. 5645 0.26 13-1 R End 63.75 51.88 Min 1450 1450 HDU5-SDS2. 5645 0.26 Line A A-1 L End 29.88 0.00 1 543 543 HDU5-SDS2. 5645 0.10 A-1 R End 53.38 0.00 1 543 543 HDU5-SDS2. 5645 0.10 Line B B-1 L End 0.12 17.00 1 4103 4103 HDU5-SDS2. 5645 0.73 V Elem 9.38 17.00 1 1940 1940 Refer to upper level B-1 R End 16.38 17.00 1 2162 2162 HDU5-SDS2. 5645 0.38 Line C C-1 L End 16.62 20.00 1 469 469 HDU5-SDS2. 5645 0.08 C-1 R End 29.63 20.00 1 465 465 HDU5-SDS2. 5645 0.08 Line D D-1 L End 29.88 22.25 1 741 741 HDU5-SDS2. 5645 0.13 V Elem 49.63 22.25 1 335 335 Refer to upper level D-1 R End 53.63 22.00 1 272 272 HDU5-SDS2. 5645 0.05 D-1 R End 53.63 22.25 1 492 492 HDU5-SDS2. 5645 0.09 D-2 R End 57.38 22.00 1 -671 Line E E-1 L End 0.12 27.00 1 2785 2785 HDU5-SDS2. 5645 0.49 E-1 R End 4.38 27.00 1 2702 2702 HDU5-SDS2. 5645 0.48 Line F V Elem 36.13 32.00 1 281 281 Refer to upper level V Elem 57.38 32.00 1 275 275 Refer to upper level Line G G-1 L End 57.63 35.00 1 7360 7360 HDU5-SDS2. 5645 1.30* G-1 R End 63.63 35.00 1 7304 7304 HDU5-SDS2. 5645 1.29* Line J J-1 L End 49.63 52.00 1 1627 1627 HDU5-SDS2. 5645 0.29 V Elem 49.88 52.00 1 1073 1073 Refer to upper level J-1 R End 63.63 52.00 1 2700 2700 HDU5-SDS2. 5645 0.48 Level 2 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 2103 2103 HDU5-SDS2. 5645 0.37 1-1 R End 0.00 22.88 Min 2103 2103 HDU5-SDS2. 5645 0.37 Line 3 20 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (flexible wind design, continued) 3-1 L End 8.50 17.13 Min 1846 1846 HDU5-SDS2.5645 0.33 3-1 R End 8.50 26.38 Min 1846 1846 HDU5-SDS2. 5645 0.33 Line 4 4-1 L End 16.50 17.13 Min 8025 8025 HDU5-SDS2. 5645 1.42* 4-1 R End 16.50 19.88 Min 8025 8025 HDU5-SDS2. 5645 1.42* Line 7 7-1 L End 29.75 0.12 Min 3257 3257 HDU5-SDS2. 5645 0.58 7-1 R End 29.75 19.88 Min 3257 3257 HDU5-SDS2. 5645 0.58 Line 11 11-1 L End 53.50 0.12 Min 2161 2161 HDU5-SDS2. 5645 0.38 11-1 R End 53.50 21.88 Min 2161 2161 HDU5-SDS2. 5645 0.38 Line 12 12-1 L End 57.50 26.13 Min 1535 1535 HDU5-SDS2. 5645 0.27 12-1 R End 57.50 34.88 Min 1535 1535 HDU5-SDS2. 5645 0.27 Line 13 13-1 L End 63.75 35.12 Min 743 743 HDU5-SDS2. 5645 0.13 13-1 R End 63.75 51.88 Min 743 743 HDU5-SDS2. 5645 0.13 Line B B-1 L End 0.12 17.00 1 1941 1941 HDU5-SDS2. 5645 0.34 B-1 R End 9.38 17.00 1 1940 1940 HDU5-SDS2. 5645 0.34 Line D D-1 L End 29.88 22.25 1 342 342 HDU5-SDS2. 5645 0.06 D-1 R End 49.63 22.25 1 335 335 HDU5-SDS2. 5645 0.06 Line F F-1 L End 36.13 32.00 1 281 281 HDU5-SDS2. 5645 0.05 F-1 R End 57.38 32.00 1 275 275 HDU5-SDS2. 5645 0.05 Line G G-1 L End 57.63 35.00 1 1839 1839 HDU5-SDS2. 5645 0.33 G-1 R End 63.63 35.00 1 1834 1834 HDU5-SDS2. 5645 0.32 Line J J-1 L End 49.88 52.00 1 1073 1073 HDU5-SDS2. 5645 0.19 J-1 R End 63.63 52.00 1 1073 1073 HDU5-SDS2. 5645 0.19 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.3-8 ASCE 7 Low-rise: Windward corner(s) and Case A or B from Fig. 28.3-1 ASCE 7 Minimum loads (27.1.5 / 28.3.4) Hold-down Forces: Shear – Wind shear overturning component, based on shearline force, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Dead – Dead load resisting component, factored for ASD by 0.60 Uplift - Uplift wind load component, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Cmb'd - Sum of ASD-factored overturning, dead and uplift forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. - Critical Response = Combined ASD force / Allowable ASD tension load Notes: Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. *WARNING - Design capacity has been exceeded. 21 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (flexible wind design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 2 2-1 Left Wall End 4.50 27.00 1 -289 287 Line 3 3-1 Right Wall End 7.75 27.25 1 1460 -1460 Line 4 4-1 Right Wall End 16.50 20.00 1 2654 -2654 Line 5 5-1 Left Wall End 19.50 42.00 1 -1044 1037 Line 8 8-1 Left Wall End 35.75 26.75 1 -1137 1130 8-1 Right Wall End 35.75 46.00 1 255 -253 Line 11 11-1 Right Wall End 53.50 22.00 1 3202 -3202 Line 12 12-1 Right Wall End 57.50 35.00 1 1125 -1125 Line C C-1 Left Wall End 16.50 20.00 1 -209 207 C-1 Right Wall End 29.75 20.00 1 301 -298 Line D D-1 Left Wall End 29.75 22.25 1 -690 672 Line E E-1 Right Wall End 4.50 27.00 1 1212 -1176 Line G G-1 Left Wall End 57.50 35.00 1 -3293 3262 Line J J-1 Right Opening 3 49.50 52.00 1 -1254 1254 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 1 1-1 Left Opening 1 0.00 23.00 1 503 -503 Line 3 3-1 Right Wall End 8.50 26.50 1 1177 -1177 Line 4 4-1 Right Wall End 16.50 20.00 1 2158 -2158 Line 7 7-1 Left Opening 1 29.75 9.50 1 1942 -1942 7-1 Right Opening 1 29.75 12.50 1 1582 -1582 Line 11 11-1 Left Opening 1 53.50 9.50 1 1429 -1429 11-1 Right Opening 1 53.50 12.50 1 1169 -1169 11-1 Right Wall End 53.50 22.00 1 2598 -2598 Line 12 12-1 Right Opening 1 57.50 26.00 1 -199 199 12-1 Right Wall End 57.50 35.00 1 846 -846 Line B B-1 Left Opening 1 9.50 17.00 1 846 -846 Line D D-1 Left Wall End 29.75 22.25 1 -388 380 D-1 Left Opening 1 49.75 22.25 1 101 -99 D-1 Right Opening 1 52.75 22.25 1 62 -61 Line F F-1 Left Wall End 36.00 32.00 1 -395 386 Line G G-1 Left Wall End 57.50 35.00 1 -1097 1094 Line J J-1 Right Opening 3 49.75 52.00 1 -584 584 J-1 Left Opening 4 58.00 52.00 1 40 -40 J-1 Right Opening 4 61.00 52.00 1 -83 83 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise corner; Case A or B 22 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force (vmax from 4.3.6.4.1.1 for perforated walls) Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 23 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Rigid Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 S->N 264.5 264.5 1587 - 1.0 - 532 1.00 532 3192 0.50 2 N->S 264.6 264.6 1587 - 1.0 - 532 1.00 532 3192 0.50 Level 1 Ln1, Lev1 1 S->N 166.2 - 1662 1.0 1.0 896 896 - A 1792 17920 0.09 1 N->S 181.9 - 1819 1.0 1.0 896 896 - A 1792 17920 0.10 Line 2 Ln2, Lev1 2 S->N 193.7 193.7 2905 - 1.0 - 532 1.00 532 7980 0.36 2 N->S 186.0 186.0 2791 - 1.0 - 532 1.00 532 7980 0.35 Line 3 Level 2 Ln3, Lev2 2 S->N 330.2 330.2 3137 - 1.0 - 532 1.00 532 5054 0.62 2 N->S 330.3 330.3 3138 - 1.0 - 532 1.00 532 5054 0.62 Level 1 Ln3, Lev1 2 S->N 129.6 129.6 1329 - 1.0 - 532 1.00 532 5453 0.24 2 N->S 141.1 141.1 1446 - 1.0 - 532 1.00 532 5453 0.27 Line 4 Level 2 Ln4, Lev2 - S->N - - 377 - - - - - - 2683 - - N->S - - 378 - - - - - - 2683 - Wall 4-1 4 S->N 125.8 - 377 - .88 - 1022 - 894 2683 0.14 4 N->S 125.8 - 378 - .88 - 1022 - 894 2683 0.14 Level 1 Ln4, Lev1 - S->N - - 152 - - - - - - 4704 - - N->S - - 147 - - - - - - 4704 - Wall 4-1 1 S->N 50.5 - 152 .88 .88 896 896 - A 1568 4704 0.03 1 N->S 49.0 - 147 .88 .88 896 896 - A 1568 4704 0.03 Line 5 Ln5, Lev1 2 S->N 45.2 45.2 181 - 1.0 - 532 1.00 532 1892 0.08 2 N->S 43.9 43.9 176 - 1.0 - 532 1.00 532 1892 0.08 Line 7 Level 2 Ln7, Lev2 - Both - - 5618 - - - - - - 9044 - Wall 7-1 2 S->N 330.4 330.4 5618 - 1.0 - 532 1.00 532 9044 0.62 2 N->S 330.5 330.5 5618 - 1.0 - 532 1.00 532 9044 0.62 Wall 7-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 - - Level 1 Ln7, Lev1 - S->N - - 4838 - - - - - - 35840 - - N->S - - 4745 - - - - - - 35840 - Wall 7-1 1 S->N 241.9 - 4838 1.0 1.0 896 896 - A 1792 35840 0.13 1 N->S 237.2 - 4745 1.0 1.0 896 896 - A 1792 35840 0.13 Wall 7-2 1 Both 0.0 - 0 1.0 1.0 896 896 - A - - - Line 8 Ln8, Lev1 - S->N - - 3994 - - - - - - 13433 - - N->S - - 3941 - - - - - - 13433 - Wall 8-1 2 S->N 207.5 207.5 3994 - 1.0 - 532 1.00 532 10241 0.39 2 N->S 204.7 204.7 3941 - 1.0 - 532 1.00 532 10241 0.38 Wall 8-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 3192 0.00 Line 11 Level 2 Ln11, Lev2 2 Both 211.6 211.6 4020 - 1.0 - 532 1.00 532 10108 0.40 Level 1 Ln11, Lev1 - S->N - - 5047 - - - - - - 39424 - - N->S - - 5082 - - - - - - 39424 - Wall 11-1 1 S->N 229.4 - 5047 1.0 1.0 896 896 - A 1792 39424 0.13 1 N->S 231.0 - 5082 1.0 1.0 896 896 - A 1792 39424 0.13 Line 12 Level 2 Ln12, Lev2 2 Both 113.2 113.2 1019 - 1.0 - 532 1.00 532 4788 0.21 Level 1 Ln12, Lev1 - S->N - - 2007 - - - - - - 23296 - - N->S - - 1924 - - - - - - 23296 - Wall 12-1 1 S->N 154.4 - 2007 1.0 1.0 896 896 - A 1792 23296 0.09 1 N->S 148.0 - 1924 1.0 1.0 896 896 - A 1792 23296 0.08 Line 13 Level 2 24 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (rigid wind design, continued) Ln13, Lev2 2 S->N 139.5 139.5 2371 - 1.0 - 532 1.00 532 9044 0.26 2 N->S 139.4 139.4 2371 - 1.0 - 532 1.00 532 9044 0.26 Level 1 Ln13, Lev1 2 S->N 125.6 125.6 2135 - 1.0 - 532 1.00 532 9044 0.24 2 N->S 128.3 128.3 2181 - 1.0 - 532 1.00 532 9044 0.24 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 1 W->E 136.1 - 3231 1.0 1.0 896 896 - A 1792 42560 0.08 1 E->W 42.1 - 999 1.0 1.0 896 896 - A 1792 42560 0.02 Line B Level 2 LnB, Lev2 2 W->E 57.4 57.4 546 - 1.0 - 532 1.00 532 5054 0.11 2 E->W 57.0 57.0 542 - 1.0 - 532 1.00 532 5054 0.11 Level 1 LnB, Lev1 1 W->E 130.4 - 2152 1.0 1.0 896 896 - A 1792 29568 0.07 1 E->W 51.4 - 847 1.0 1.0 896 896 - A 1792 29568 0.03 Line C LnC, Lev1 - W->E - - 1534 - - - - - - 23744 - - E->W - - 603 - - - - - - 23744 - Wall C-1 1 W->E 115.8 - 1534 1.0 1.0 896 896 - A 1792 23744 0.06 1 E->W 45.5 - 603 1.0 1.0 896 896 - A 1792 23744 0.03 Line D Level 2 LnD, Lev2 - W->E - - 2256 - - - - - - 12532 - - E->W - - 2243 - - - - - - 12532 - Wall D-1 2 W->E 112.8 112.8 2256 - 1.0 - 532 1.00 532 10640 0.21 2 E->W 112.1 112.1 2243 - 1.0 - 532 1.00 532 10640 0.21 Wall D-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 1892 0.00 Level 1 LnD, Lev1 - W->E - - 5214 - - - - - - 49952 - - E->W - - 11054 - - - - - - 49952 - Wall D-1 1 W->E 216.0 - 5184 1.0 1.0 896 896 - A 1792 43008 0.12 1 E->W 460.6 - 11054 1.0 1.0 896 896 - A 1792 43008 0.26 Wall D-2 1 W->E 7.5 - 30 .97 .97 896 896 - A 1736 6944 0.00 1 E->W 0.0 - 0 .97 .97 896 896 - A 1736 6944 0.00 Line E LnE, Lev1 - W->E - - 211 - - - - - - 8064 - - E->W - - 87 - - - - - - 8064 - Wall E-1 1 W->E 46.8 - 211 1.0 1.0 896 896 - A 1792 8064 0.03 1 E->W 19.4 - 87 1.0 1.0 896 896 - A 1792 8064 0.01 Line F Level 2 LnF, Lev2 2 W->E 105.5 105.5 2269 - 1.0 - 532 1.00 532 11438 0.20 2 E->W 104.9 104.9 2255 - 1.0 - 532 1.00 532 11438 0.20 Line G LnG, Lev2 - W->E - - 239 - - - - - - 4288 - - E->W - - 237 - - - - - - 4288 - Wall G-1 3 W->E 38.2 - 239 - 1.0 - 686 - 686 4288 0.06 3 E->W 38.0 - 237 - 1.0 - 686 - 686 4288 0.06 Level 1 LnG, Lev1 - W->E - - 442 - - - - - - 11200 - - E->W - - 192 - - - - - - 11200 - Wall G-1 1 W->E 70.7 - 442 1.0 1.0 896 896 - A 1792 11200 0.04 1 E->W 30.8 - 192 1.0 1.0 896 896 - A 1792 11200 0.02 Line J Level 2 LnJ, Lev2 2 W->E 43.8 43.8 482 - 1.0 - 532 1.00 532 5283 0.08 2 E->W 43.6 43.6 479 - 1.0 - 532 1.00 532 5283 0.08 Level 1 LnJ, Lev1 2 W->E 145.6 145.6 2074 - 1.0 - 532 1.00 532 7581 0.27 2 E->W 67.5 67.5 961 - 1.0 - 532 1.00 532 7581 0.13 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 25 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 26 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (rigid wind design) Level 1 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 4188 4188 HDU5-SDS2. 5645 0.74 V Elem 0.00 22.88 Min 2654 2654 Refer to upper level 1-1 R End 0.00 26.88 Min 1679 1679 HDU5-SDS2. 5645 0.30 Line 2 2-1 L End 4.50 27.13 Min 1773 1773 HDU5-SDS2. 5645 0.31 2-1 R End 4.50 41.88 Min 1703 1703 HDU5-SDS2. 5645 0.30 Line 3 3-1 L End 7.75 17.13 Min 4248 4248 HDU5-SDS2. 5645 0.75 V Elem 8.50 26.38 Min 3053 3053 Refer to upper level 3-1 R End 7.75 27.13 Min 1301 1301 HDU5-SDS2. 5645 0.23 Line 4 4-1 L End 16.50 17.13 Min 1732 1732 HDU5-SDS2. 5645 0.31 4-1 R End 16.50 19.88 Min 1716 1716 HDU5-SDS2. 5645 0.30 Line 5 5-1 L End 19.50 42.13 Min 488 488 HDU5-SDS2. 5645 0.09 5-1 R End 19.50 45.88 Min 474 474 HDU5-SDS2. 5645 0.08 Line 7 7-1 L End 29.75 0.12 Min 5524 5524 HDU5-SDS2. 5645 0.98 7-1 R End 29.75 19.88 Min 5482 5482 HDU5-SDS2. 5645 0.97 Line 8 8-1 L End 35.75 26.88 Min 1892 1892 HDU5-SDS2. 5645 0.34 8-1 R End 35.75 45.88 Min 1867 1867 HDU5-SDS2. 5645 0.33 Line 11 11-1 L End 53.50 0.12 Min 4018 4018 HDU5-SDS2. 5645 0.71 11-1 R End 53.50 21.88 Min 4033 4033 HDU5-SDS2. 5645 0.71 Line 12 12-1 L End 57.50 22.13 Min 1417 1417 HDU5-SDS2. 5645 0.25 V Elem 57.50 26.13 Min 1048 1048 Refer to upper level 12-1 R End 57.50 34.88 Min 2406 2406 HDU5-SDS2. 5645 0.43 Line 13 13-1 L End 63.75 35.12 Min 2882 2882 HDU5-SDS2. 5645 0.51 13-1 R End 63.75 51.88 Min 2906 2906 HDU5-SDS2. 5645 0.51 Line A A-1 L End 29.88 0.00 1 1238 1238 HDU5-SDS2. 5645 0.22 A-1 R End 53.38 0.00 1 383 383 HDU5-SDS2. 5645 0.07 Line B B-1 L End 0.12 17.00 1 1723 1723 HDU5-SDS2. 5645 0.31 V Elem 9.38 17.00 1 527 527 Refer to upper level B-1 R End 16.38 17.00 1 469 469 HDU5-SDS2. 5645 0.08 Line C C-1 L End 16.62 20.00 1 1062 1062 HDU5-SDS2. 5645 0.19 C-1 R End 29.63 20.00 1 417 417 HDU5-SDS2. 5645 0.07 Line D D-1 L End 29.88 22.25 1 2993 2993 HDU5-SDS2. 5645 0.53 V Elem 49.63 22.25 1 1022 1022 Refer to upper level D-1 R End 53.63 22.25 1 4189 4189 HDU5-SDS2. 5645 0.74 D-1 R End 53.63 22.00 1 -1893 Line E E-1 L End 0.12 27.00 1 446 446 HDU5-SDS2. 5645 0.08 E-1 R End 4.38 27.00 1 185 185 HDU5-SDS2. 5645 0.03 Line F V Elem 36.13 32.00 1 961 961 Refer to upper level V Elem 57.38 32.00 1 955 955 Refer to upper level Line G G-1 L End 57.63 35.00 1 1022 1022 HDU5-SDS2. 5645 0.18 G-1 R End 63.63 35.00 1 645 645 HDU5-SDS2. 5645 0.11 Line J J-1 L End 49.63 52.00 1 1333 1333 HDU5-SDS2. 5645 0.24 V Elem 49.88 52.00 1 447 447 Refer to upper level J-1 R End 63.63 52.00 1 1062 1062 HDU5-SDS2. 5645 0.19 Level 2 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 2654 2654 HDU5-SDS2. 5645 0.47 1-1 R End 0.00 22.88 Min 2654 2654 HDU5-SDS2. 5645 0.47 Line 3 3-1 L End 8.50 17.13 Min 3053 3053 HDU5-SDS2.5645 0.54 27 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (rigid wind design, continued) 3-1 R End 8.50 26.38 Min 3053 3053 HDU5-SDS2.5645 0.54 Line 4 4-1 L End 16.50 17.13 Min 1235 1235 HDU5-SDS2. 5645 0.22 4-1 R End 16.50 19.88 Min 1235 1235 HDU5-SDS2. 5645 0.22 Line 7 7-1 L End 29.75 0.12 Min 3320 3320 HDU5-SDS2. 5645 0.59 7-1 R End 29.75 19.88 Min 3320 3320 HDU5-SDS2. 5645 0.59 Line 11 11-1 L End 53.50 0.12 Min 1930 1930 HDU5-SDS2. 5645 0.34 11-1 R End 53.50 21.88 Min 1929 1929 HDU5-SDS2. 5645 0.34 Line 12 12-1 L End 57.50 26.13 Min 1048 1048 HDU5-SDS2. 5645 0.19 12-1 R End 57.50 34.88 Min 1048 1048 HDU5-SDS2. 5645 0.19 Line 13 13-1 L End 63.75 35.12 Min 1735 1735 HDU5-SDS2. 5645 0.31 13-1 R End 63.75 51.88 Min 1734 1734 HDU5-SDS2. 5645 0.31 Line B B-1 L End 0.12 17.00 1 531 531 HDU5-SDS2. 5645 0.09 B-1 R End 9.38 17.00 1 527 527 HDU5-SDS2. 5645 0.09 Line D D-1 L End 29.88 22.25 1 1028 1028 HDU5-SDS2. 5645 0.18 D-1 R End 49.63 22.25 1 1022 1022 HDU5-SDS2. 5645 0.18 Line F F-1 L End 36.13 32.00 1 961 961 HDU5-SDS2. 5645 0.17 F-1 R End 57.38 32.00 1 955 955 HDU5-SDS2. 5645 0.17 Line G G-1 L End 57.63 35.00 1 358 358 HDU5-SDS2. 5645 0.06 G-1 R End 63.63 35.00 1 356 356 HDU5-SDS2. 5645 0.06 Line J J-1 L End 49.88 52.00 1 447 447 HDU5-SDS2. 5645 0.08 J-1 R End 63.63 52.00 1 444 444 HDU5-SDS2. 5645 0.08 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.3-8 ASCE 7 Low-rise: Windward corner(s) and Case A or B from Fig. 28.3-1 ASCE 7 Minimum loads (27.1.5 / 28.3.4) Hold-down Forces: Shear – Wind shear overturning component, based on shearline force, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Dead – Dead load resisting component, factored for ASD by 0.60 Uplift - Uplift wind load component, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Cmb'd - Sum of ASD-factored overturning, dead and uplift forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. - Critical Response = Combined ASD force / Allowable ASD tension load Notes: Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. 28 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (rigid wind design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 2 2-1 Left Wall End 4.50 27.00 1 -1162 1116 Line 3 3-1 Right Wall End 7.75 27.25 1 784 -853 Line 4 4-1 Right Wall End 16.50 20.00 1 133 -129 Line 5 5-1 Left Wall End 19.50 42.00 1 -153 149 Line 8 8-1 Left Wall End 35.75 26.75 1 -2055 2027 8-1 Right Wall End 35.75 46.00 1 461 -455 Line 11 11-1 Right Wall End 53.50 22.00 1 2912 -2932 Line 12 12-1 Right Wall End 57.50 35.00 1 1137 -1090 Line C C-1 Left Wall End 16.50 20.00 1 -473 186 C-1 Right Wall End 29.75 20.00 1 681 -268 Line D D-1 Left Wall End 29.75 22.25 1 -2698 5719 Line E E-1 Right Wall End 4.50 27.00 1 194 -80 Line G G-1 Left Wall End 57.50 35.00 1 -396 172 Line J J-1 Right Opening 3 49.50 52.00 1 -1028 476 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 1 1-1 Left Opening 1 0.00 23.00 1 635 -635 Line 3 3-1 Right Wall End 8.50 26.50 1 1945 -1945 Line 4 4-1 Right Wall End 16.50 20.00 1 332 -332 Line 7 7-1 Left Opening 1 29.75 9.50 1 1979 -1979 7-1 Right Opening 1 29.75 12.50 1 1613 -1613 Line 11 11-1 Left Opening 1 53.50 9.50 1 1276 -1276 11-1 Right Opening 1 53.50 12.50 1 1044 -1044 11-1 Right Wall End 53.50 22.00 1 2319 -2319 Line 12 12-1 Right Opening 1 57.50 26.00 1 -136 136 12-1 Right Wall End 57.50 35.00 1 578 -577 Line B B-1 Left Opening 1 9.50 17.00 1 231 -230 Line D D-1 Left Wall End 29.75 22.25 1 -1167 1160 D-1 Left Opening 1 49.75 22.25 1 304 -302 D-1 Right Opening 1 52.75 22.25 1 186 -185 Line F F-1 Left Wall End 36.00 32.00 1 -1348 1340 Line G G-1 Left Wall End 57.50 35.00 1 -214 212 Line J J-1 Right Opening 3 49.75 52.00 1 -243 242 J-1 Left Opening 4 58.00 52.00 1 17 -16 J-1 Right Opening 4 61.00 52.00 1 -35 34 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise corner; Case A or B 29 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force (vmax from 4.3.6.4.1.1 for perforated walls) Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 30 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force [lbs] [lbs][sq.ft]E-W N-S E-W: Fpx Design N-S: Fpx Design 2 62661 2104.2 12901 12901 9357 9357 9357 9357 1 46974 2104.2 5090 5090 7015 9974 7015 7015 All 109634 - 17991 17991 - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Story Shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm Force – Minimum ASD-factored force for diaphragm design, used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx is from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 2.5 as per 12.2-1. Redundancy Factor p (rho): E-W 1.30, N-S 1.30 Input by user (overriding calculated value). Applies to shearwall design, hold-down forces and the drag strut force component based on shearline forces; does not apply to story drift, out-of-plane force, or the diaphragm force Fpx and the drag strut force component based on it. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.07; Ev = 0.213 D unfactored; 0.149 D factored; total dead load factor: 0.6 - 0.149 = 0.451 tension, 1.0 + 0.149 = 1.149 compression. 31 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (flexible seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 161.7 161.7 970 - 1.0 - 380 1.00 380 2280 0.43 Level 1 Ln1, Lev1 1 Both 112.1 - 1121 1.0 1.0 640 640 - A 1280 12800 0.09 Line 2 Ln2, Lev1 2 Both 17.6 17.6 264 - 1.0 - 380 1.00 380 5700 0.05 Line 3 Level 2 Ln3, Lev2 2 Both 119.5 119.5 1135 - 1.0 - 380 1.00 380 3610 0.31 Level 1 Ln3, Lev1 2 Both 140.5 140.5 1440 - 1.0 - 380 1.00 380 3895 0.37 Line 4 Level 2 Ln4, Lev2 - Both - - 1383 - - - - - - 1916 - Wall 4-1 4 Both 461.0 - 1383 - .88 - 730 - 639 1916 0.72 Level 1 Ln4, Lev1 - Both - - 1656 - - - - - - 3360 - Wall 4-1 1 Both 552.2 - 1656 .88 .88 640 640 - A 1120 3360 0.49 Line 5 Ln5, Lev1 2 Both 85.4 85.4 341 - 1.0 - 380 1.00 380 1351 0.22 Line 7 Level 2 Ln7, Lev2 - Both - - 3507 - - - - - - 6460 - Wall 7-1 2 Both 206.3 206.3 3507 - 1.0 - 380 1.00 380 6460 0.54 Wall 7-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 - - Level 1 Ln7, Lev1 - Both - - 4149 - - - - - - 25600 - Wall 7-1 1 Both 207.5 - 4149 1.0 1.0 640 640 - A 1280 25600 0.16 Wall 7-2 1 Both 0.0 - 0 1.0 1.0 0 0 - A - - - Line 8 Ln8, Lev1 - Both - - 1047 - - - - - - 9595 - Wall 8-1 2 Both 54.4 54.4 1047 - 1.0 - 380 1.00 380 7315 0.14 Wall 8-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 2280 0.00 Line 11 Level 2 Ln11, Lev2 2 Both 154.2 154.2 2930 - 1.0 - 380 1.00 380 7220 0.41 Level 1 Ln11, Lev1 - Both - - 3957 - - - - - - 28160 - Wall 11-1 1 Both 179.9 - 3957 1.0 1.0 640 640 - A 1280 28160 0.14 Line 12 Level 2 Ln12, Lev2 2 Both 108.2 108.2 973 - 1.0 - 380 1.00 380 3420 0.28 Level 1 Ln12, Lev1 - Both - - 1297 - - - - - - 16640 - Wall 12-1 1 Both 99.7 - 1297 1.0 1.0 640 640 - A 1280 16640 0.08 Line 13 Level 2 Ln13, Lev2 2 Both 49.5 49.5 841 - 1.0 - 380 1.00 380 6460 0.13 Level 1 Ln13, Lev1 2 Both 64.7 64.7 1100 - 1.0 - 380 1.00 380 6460 0.17 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 LnA, Lev1 1 Both 23.6 - 561 1.0 1.0 640 640 - A 1280 30400 0.02 Line B Level 2 LnB, Lev2 2^Both 349.9 349.9 3324 - 1.0 - 380 1.00 380 3610 0.92 Level 1 LnB, Lev1 1 Both 238.9 - 3942 1.0 1.0 640 640 - A 1280 21120 0.19 Line C LnC, Lev1 - Both - - 332 - - - - - - 16960 - Wall C-1 1 Both 25.0 - 332 1.0 1.0 640 640 - A 1280 16960 0.02 Line D Level 2 LnD, Lev2 - Both - - 1925 - - - - - - 8951 - Wall D-1 2 Both 96.2 96.2 1925 - 1.0 - 380 1.00 380 7600 0.25 Wall D-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 1351 0.00 32 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (flexible seismic design, continued) Level 1 LnD, Lev1 - Both - - 2370 - - - - - - 35680 - Wall D-1 1 W->E 45.7 - 1097 1.0 1.0 640 640 - A 1280 30720 0.04 1 E->W 98.8 - 2370 1.0 1.0 640 640 - A 1280 30720 0.08 Wall D-2 1 W->E 318.4 - 1273 .97 .97 640 640 - A 1240 4960 0.26 1 E->W 0.0 - 0 .97 .97 640 640 - A 1240 4960 0.00 Line E LnE, Lev1 - Both - - 1175 - - - - - - 5760 - Wall E-1 1 Both 261.1 - 1175 1.0 1.0 640 640 - A 1280 5760 0.20 Line F Level 2 LnF, Lev2 2 Both 71.6 71.6 1539 - 1.0 - 380 1.00 380 8170 0.19 Line G LnG, Lev2 - Both - - 2401 - - - - - - 3063 - Wall G-1 3^Both 384.2 - 2401 - 1.0 - 490 - 490 3063 0.78 Level 1 LnG, Lev1 - Both - - 4544 - - - - - - 8000 - Wall G-1 1 Both 727.1 - 4544 1.0 1.0 640 640 - A 1280 8000 0.57 Line J Level 2 LnJ, Lev2 2 Both 233.5 233.5 2569 - 1.0 - 380 1.00 380 3774 0.61 Level 1 LnJ, Lev1 2 Both 243.3 243.3 3467 - 1.0 - 380 1.00 380 5415 0.64 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 33 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (flexible seismic design) Level 1 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 2658 2658 HDU5-SDS2.5645 0.47 V Elem 0.00 22.88 1623 1623 Refer to upper level 1-1 R End 0.00 26.88 1035 1035 HDU5-SDS2.5645 0.18 Line 2 2-1 L End 4.50 27.13 161 161 HDU5-SDS2.5645 0.03 2-1 R End 4.50 41.88 161 161 HDU5-SDS2.5645 0.03 Line 3 3-1 L End 7.75 17.13 2401 2401 HDU5-SDS2.5645 0.43 V Elem 8.50 26.38 1104 1104 Refer to upper level 3-1 R End 7.75 27.13 1296 1296 HDU5-SDS2.5645 0.23 Line 4 4-1 L End 16.50 17.13 9947 9947 HDU5-SDS2.5645 1.76* 4-1 R End 16.50 19.88 9947 9947 HDU5-SDS2.5645 1.76* Line 5 5-1 L End 19.50 42.13 922 922 HDU5-SDS2.5645 0.16 5-1 R End 19.50 45.88 922 922 HDU5-SDS2.5645 0.16 Line 7 7-1 L End 29.75 0.12 3963 3963 HDU5-SDS2.5645 0.70 7-1 R End 29.75 19.88 3963 3963 HDU5-SDS2.5645 0.70 Line 8 8-1 L End 35.75 26.88 496 496 HDU5-SDS2.5645 0.09 8-1 R End 35.75 45.88 496 496 HDU5-SDS2.5645 0.09 Line 11 11-1 L End 53.50 0.12 3044 3044 HDU5-SDS2.5645 0.54 11-1 R End 53.50 21.88 3044 3044 HDU5-SDS2.5645 0.54 Line 12 12-1 L End 57.50 22.13 915 915 HDU5-SDS2.5645 0.16 V Elem 57.50 26.13 1001 1001 Refer to upper level 12-1 R End 57.50 34.88 1916 1916 HDU5-SDS2.5645 0.34 Line 13 13-1 L End 63.75 35.12 1206 1206 HDU5-SDS2.5645 0.21 13-1 R End 63.75 51.88 1206 1206 HDU5-SDS2.5645 0.21 Line A A-1 L End 29.88 0.00 215 215 HDU5-SDS2.5645 0.04 A-1 R End 53.38 0.00 215 215 HDU5-SDS2.5645 0.04 Line B B-1 L End 0.12 17.00 5418 5418 HDU5-SDS2.5645 0.96 V Elem 9.38 17.00 3235 3235 Refer to upper level B-1 R End 16.38 17.00 2183 2183 HDU5-SDS2.5645 0.39 Line C C-1 L End 16.62 20.00 230 230 HDU5-SDS2.5645 0.04 C-1 R End 29.63 20.00 230 230 HDU5-SDS2.5645 0.04 Line D D-1 L End 29.88 22.25 1293 1293 HDU5-SDS2.5645 0.23 V Elem 49.63 22.25 877 877 Refer to upper level D-1 R End 53.63 22.00 2641 2641 HDU5-SDS2.5645 0.47 D-1 R End 53.63 22.25 898 898 HDU5-SDS2.5645 0.16 D-2 R End 57.38 22.00 -3056 Line E E-1 L End 0.12 27.00 2488 2488 HDU5-SDS2.5645 0.44 E-1 R End 4.38 27.00 2488 2488 HDU5-SDS2.5645 0.44 Line F V Elem 36.13 32.00 652 652 Refer to upper level V Elem 57.38 32.00 652 652 Refer to upper level Line G G-1 L End 57.63 35.00 10418 10418 HDU5-SDS2.5645 1.85* G-1 R End 63.63 35.00 10418 10418 HDU5-SDS2.5645 1.85* Line J J-1 L End 49.63 52.00 2229 2229 HDU5-SDS2.5645 0.39 V Elem 49.88 52.00 2382 2382 Refer to upper level J-1 R End 63.63 52.00 4611 4611 HDU5-SDS2.5645 0.82 Level 2 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 1623 1623 HDU5-SDS2. 5645 0.29 1-1 R End 0.00 22.88 1623 1623 HDU5-SDS2. 5645 0.29 Line 3 34 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (flexible seismic design, continued) 3-1 L End 8.50 17.13 1104 1104 HDU5-SDS2.5645 0.20 3-1 R End 8.50 26.38 1104 1104 HDU5-SDS2. 5645 0.20 Line 4 4-1 L End 16.50 17.13 4526 4526 HDU5-SDS2. 5645 0.80 4-1 R End 16.50 19.88 4526 4526 HDU5-SDS2. 5645 0.80 Line 7 7-1 L End 29.75 0.12 2072 2072 HDU5-SDS2. 5645 0.37 7-1 R End 29.75 19.88 2072 2072 HDU5-SDS2. 5645 0.37 Line 11 11-1 L End 53.50 0.12 1407 1407 HDU5-SDS2. 5645 0.25 11-1 R End 53.50 21.88 1407 1407 HDU5-SDS2. 5645 0.25 Line 12 12-1 L End 57.50 26.13 1001 1001 HDU5-SDS2. 5645 0.18 12-1 R End 57.50 34.88 1001 1001 HDU5-SDS2. 5645 0.18 Line 13 13-1 L End 63.75 35.12 615 615 HDU5-SDS2. 5645 0.11 13-1 R End 63.75 51.88 615 615 HDU5-SDS2. 5645 0.11 Line B B-1 L End 0.12 17.00 3235 3235 HDU5-SDS2. 5645 0.57 B-1 R End 9.38 17.00 3235 3235 HDU5-SDS2. 5645 0.57 Line D D-1 L End 29.88 22.25 877 877 HDU5-SDS2. 5645 0.16 D-1 R End 49.63 22.25 877 877 HDU5-SDS2. 5645 0.16 Line F F-1 L End 36.13 32.00 652 652 HDU5-SDS2. 5645 0.12 F-1 R End 57.38 32.00 652 652 HDU5-SDS2. 5645 0.12 Line G G-1 L End 57.63 35.00 3602 3602 HDU5-SDS2. 5645 0.64 G-1 R End 63.63 35.00 3602 3602 HDU5-SDS2. 5645 0.64 Line J J-1 L End 49.88 52.00 2382 2382 HDU5-SDS2. 5645 0.42 J-1 R End 63.63 52.00 2382 2382 HDU5-SDS2. 5645 0.42 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Hold-down Forces: Shear – Seismic shear overturning component, factored for ASD by 0.7. For perforated walls, T from SDPWS 4.3-8 is used Dead – Dead load resisting component, factored for ASD by 0.60 Ev – Vertical seismic load effect from ASCE 7 12.4.2.2 = -0.2Sds x ASD seismic factor x unfactored D = 0.249 x factored D. Refer to Seismic Information table for more details. Cmb'd - Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. – Critical Response = Combined ASD force/Allowable ASD tension load Notes: Combined force from ASCE 7 2.4.1 load combination 10 = - (0.6D - 0.7Ev + 0.7Eh); Eh (from 12.4.2.1) = - shear overturning force Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. *WARNING - Design capacity has been exceeded. 35 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (flexible seismic design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 2 Shearline force 385 385 2-1 Left Wall End 4.50 27.00 -154 154 Line 3 Shearline force 1863 1863 3-1 Right Wall End 7.75 27.25 1099 -1099 Line 4 Shearline force 2127 2127 4-1 Right Wall End 16.50 20.00 1872 -1872 Line 5 Shearline force 497 497 5-1 Left Wall End 19.50 42.00 -421 421 Line 8 Shearline force 1524 1524 8-1 Left Wall End 35.75 26.75 -784 784 8-1 Right Wall End 35.75 46.00 176 -176 Line 11 Shearline force 5157 5157 11-1 Right Wall End 53.50 22.00 2975 -2975 Line 12 Shearline force 1687 1687 12-1 Right Wall End 57.50 35.00 956 -956 Line C Shearline force 359 359 C-1 Left Wall End 16.50 20.00 -111 111 C-1 Right Wall End 29.75 20.00 159 -159 Line D Shearline force 2407 2407 D-1 Left Wall End 29.75 22.25 -1245 1245 Line E Shearline force 1757 1757 E-1 Right Wall End 4.50 27.00 1619 -1619 Line G Shearline force 5529 5529 G-1 Left Wall End 57.50 35.00 -4945 4945 Line J Shearline force 3540 3540 J-1 Right Opening 3 49.50 52.00 -1754 1754 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 1 Shearline force 970 970 1-1 Left Opening 1 0.00 23.00 388 -388 Line 3 Shearline force 1135 1135 3-1 Right Wall End 8.50 26.50 704 -704 Line 4 Shearline force 1383 1383 4-1 Right Wall End 16.50 20.00 1217 -1217 Line 7 Shearline force 3507 3507 7-1 Left Opening 1 29.75 9.50 1235 -1235 7-1 Right Opening 1 29.75 12.50 1007 -1007 Line 11 Shearline force 2930 2930 11-1 Left Opening 1 53.50 9.50 930 -930 11-1 Right Opening 1 53.50 12.50 761 -761 11-1 Right Wall End 53.50 22.00 1691 -1691 Line 12 Shearline force 973 973 12-1 Right Opening 1 57.50 26.00 -130 130 12-1 Right Wall End 57.50 35.00 552 -552 Line B Shearline force 3324 3324 B-1 Left Opening 1 9.50 17.00 1410 -1410 Line D Shearline force 1925 1925 36 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (flexible seismic design, continued) D-1 Left Wall End 29.75 22.25 -996 996 D-1 Left Opening 1 49.75 22.25 259 -259 D-1 Right Opening 1 52.75 22.25 159 -159 Line F Shearline force 1539 1539 F-1 Left Wall End 36.00 32.00 -915 915 Line G Shearline force 2401 2401 G-1 Left Wall End 57.50 35.00 -2148 2148 Line J Shearline force 2569 2569 J-1 Right Opening 3 49.75 52.00 -1296 1296 J-1 Left Opening 4 58.00 52.00 88 -88 J-1 Right Opening 4 61.00 52.00 -185 185 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force shown. For SDC C-F, it is the greater of the design shearline force and the diaphragm force Fpx, added to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength (omega) as per 12.10.1.1. Refer to Seismic Information table for diaphragm forces and omega factor. For SDC D-F, if horizontal torsional irregularities 2, 3, or 4 are input, or vertical irregularity 4 detected or input, 25% increase from 12.3.3.4 applied. For perforated walls, this force is converted to vmax using 4.3.6.4.1.1. Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 37 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 Rigid Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force [lbs] [lbs][sq.ft]E-W N-S E-W: Fpx Design N-S: Fpx Design 2 62661 2104.2 12901 12901 9357 9357 9357 9357 1 46974 2104.2 5090 5090 7015 17595 7015 7015 All 109634 - 17991 17991 - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Story Shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm Force – Minimum ASD-factored force for diaphragm design, used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx is from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 3.0 as per 12.2-1. On at least one level and force direction, a torsional irregularity was detected and torsional amplification factor Ax applied according to 12.8.4.3. Refer to the Torsional Analysis section of the Log File output for the values of Ax. Redundancy Factor p (rho): E-W 1.30, N-S 1.30 Input by user (overriding calculated value). Applies to shearwall design, hold-down forces and the drag strut force component based on shearline forces; does not apply to story drift, out-of-plane force, or the diaphragm force Fpx and the drag strut force component based on it. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.07; Ev = 0.213 D unfactored; 0.149 D factored; total dead load factor: 0.6 - 0.149 = 0.451 tension, 1.0 + 0.149 = 1.149 compression. 38 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (rigid seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 199.2 199.2 1195 - 1.0 - 380 1.00 380 2280 0.52 Level 1 Ln1, Lev1 1 S->N 125.0 - 1250 1.0 1.0 640 640 - A 1280 12800 0.10 1 N->S 137.9 - 1379 1.0 1.0 640 640 - A 1280 12800 0.11 Line 2 Ln2, Lev1 2 S->N 149.7 149.7 2246 - 1.0 - 380 1.00 380 5700 0.39 2 N->S 144.1 144.1 2162 - 1.0 - 380 1.00 380 5700 0.38 Line 3 Level 2 Ln3, Lev2 2 Both 245.0 245.0 2328 - 1.0 - 380 1.00 380 3610 0.64 Level 1 Ln3, Lev1 2 S->N 96.5 96.5 989 - 1.0 - 380 1.00 380 3895 0.25 2 N->S 105.9 105.9 1086 - 1.0 - 380 1.00 380 3895 0.28 Line 4 Level 2 Ln4, Lev2 - Both - - 256 - - - - - - 1916 - Wall 4-1 4 Both 85.2 - 256 - .88 - 730 - 639 1916 0.13 Level 1 Ln4, Lev1 - S->N - - 104 - - - - - - 3360 - - N->S - - 100 - - - - - - 3360 - Wall 4-1 1 S->N 34.5 - 104 .88 .88 640 640 - A 1120 3360 0.03 1 N->S 33.5 - 100 .88 .88 640 640 - A 1120 3360 0.03 Line 5 Ln5, Lev1 2 S->N 30.7 30.7 123 - 1.0 - 380 1.00 380 1351 0.08 2 N->S 29.8 29.8 119 - 1.0 - 380 1.00 380 1351 0.08 Line 7 Level 2 Ln7, Lev2 - Both - - 3807 - - - - - - 6460 - Wall 7-1 2 Both 223.9 223.9 3807 - 1.0 - 380 1.00 380 6460 0.59 Wall 7-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 - - Level 1 Ln7, Lev1 - S->N - - 3121 - - - - - - 25600 - - N->S - - 3055 - - - - - - 25600 - Wall 7-1 1 S->N 156.0 - 3121 1.0 1.0 640 640 - A 1280 25600 0.12 1 N->S 152.7 - 3055 1.0 1.0 640 640 - A 1280 25600 0.12 Wall 7-2 1 Both 0.0 - 0 1.0 1.0 0 0 - A - - - Line 8 Ln8, Lev1 - S->N - - 2704 - - - - - - 9595 - - N->S - - 2660 - - - - - - 9595 - Wall 8-1 2 S->N 140.5 140.5 2704 - 1.0 - 380 1.00 380 7315 0.37 2 N->S 138.2 138.2 2660 - 1.0 - 380 1.00 380 7315 0.36 Wall 8-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 2280 0.00 Line 11 Level 2 Ln11, Lev2 2 Both 159.2 159.2 3025 - 1.0 - 380 1.00 380 7220 0.42 Level 1 Ln11, Lev1 - S->N - - 3955 - - - - - - 28160 - - N->S - - 3978 - - - - - - 28160 - Wall 11-1 1 S->N 179.8 - 3955 1.0 1.0 640 640 - A 1280 28160 0.14 1 N->S 180.8 - 3978 1.0 1.0 640 640 - A 1280 28160 0.14 Line 12 Level 2 Ln12, Lev2 2 Both 89.9 89.9 809 - 1.0 - 380 1.00 380 3420 0.24 Level 1 Ln12, Lev1 - S->N - - 1659 - - - - - - 16640 - - N->S - - 1579 - - - - - - 16640 - Wall 12-1 1 S->N 127.6 - 1659 1.0 1.0 640 640 - A 1280 16640 0.10 1 N->S 121.4 - 1579 1.0 1.0 640 640 - A 1280 16640 0.09 Line 13 Level 2 Ln13, Lev2 2 Both 130.7 130.7 2222 - 1.0 - 380 1.00 380 6460 0.34 Level 1 Ln13, Lev1 2 S->N 114.6 114.6 1947 - 1.0 - 380 1.00 380 6460 0.30 2 N->S 116.2 116.2 1975 - 1.0 - 380 1.00 380 6460 0.31 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 1 39 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 SHEAR RESULTS (rigid seismic design, continued) LnA, Lev1 1 W->E 124.1 - 2948 1.0 1.0 640 640 - A 1280 30400 0.10 1 E->W 51.1 - 1213 1.0 1.0 640 640 - A 1280 30400 0.04 Line B Level 2 LnB, Lev2 2 Both 131.5 131.5 1250 - 1.0 - 380 1.00 380 3610 0.35 Level 1 LnB, Lev1 1 W->E 117.4 - 1938 1.0 1.0 640 640 - A 1280 21120 0.09 1 E->W 63.1 - 1041 1.0 1.0 640 640 - A 1280 21120 0.05 Line C LnC, Lev1 - W->E - - 1480 - - - - - - 16960 - - E->W - - 743 - - - - - - 16960 - Wall C-1 1 W->E 111.7 - 1480 1.0 1.0 640 640 - A 1280 16960 0.09 1 E->W 56.1 - 743 1.0 1.0 640 640 - A 1280 16960 0.04 Line D Level 2 LnD, Lev2 - Both - - 4475 - - - - - - 8951 - Wall D-1 2 Both 223.8 223.8 4475 - 1.0 - 380 1.00 380 7600 0.59 Wall D-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 1351 0.00 Level 1 LnD, Lev1 - W->E - - 7461 - - - - - - 35680 - - E->W - - 12250 - - - - - - 35680 - Wall D-1 1 W->E 188.9 - 4533 1.0 1.0 640 640 - A 1280 30720 0.15 1 E->W 510.4 - 12250 1.0 1.0 640 640 - A 1280 30720 0.40 Wall D-2 1 W->E 732.0 - 2928 .97 .97 640 640 - A 1240 4960 0.59 1 E->W 0.0 - 0 .97 .97 640 640 - A 1240 4960 0.00 Line E LnE, Lev1 - W->E - - 229 - - - - - - 5760 - - E->W - - 126 - - - - - - 5760 - Wall E-1 1 W->E 50.9 - 229 1.0 1.0 640 640 - A 1280 5760 0.04 1 E->W 28.0 - 126 1.0 1.0 640 640 - A 1280 5760 0.02 Line F Level 2 LnF, Lev2 2 Both 213.3 213.3 4585 - 1.0 - 380 1.00 380 8170 0.56 Line G LnG, Lev2 - Both - - 580 - - - - - - 3063 - Wall G-1 3 Both 92.8 - 580 - 1.0 - 490 - 490 3063 0.19 Level 1 LnG, Lev1 - W->E - - 513 - - - - - - 8000 - - E->W - - 306 - - - - - - 8000 - Wall G-1 1 W->E 82.2 - 513 1.0 1.0 640 640 - A 1280 8000 0.06 1 E->W 49.0 - 306 1.0 1.0 640 640 - A 1280 8000 0.04 Line J Level 2 LnJ, Lev2 2 Both 133.3 133.3 1324 - 1.0 - 380 1.00 380 3774 0.35 Level 1 LnJ, Lev1 2 W->E 192.0 192.0 2736 - 1.0 - 380 1.00 380 5415 0.51 2 E->W 120.2 120.2 1713 - 1.0 - 380 1.00 380 5415 0.32 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. 40 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (rigid seismic design) Level 1 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 3153 3153 HDU5-SDS2.5645 0.56 V Elem 0.00 22.88 1998 1998 Refer to upper level 1-1 R End 0.00 26.88 1272 1272 HDU5-SDS2.5645 0.23 Line 2 2-1 L End 4.50 27.13 1370 1370 HDU5-SDS2.5645 0.24 2-1 R End 4.50 41.88 1319 1319 HDU5-SDS2.5645 0.23 Line 3 3-1 L End 7.75 17.13 3155 3155 HDU5-SDS2.5645 0.56 V Elem 8.50 26.38 2265 2265 Refer to upper level 3-1 R End 7.75 27.13 977 977 HDU5-SDS2.5645 0.17 Line 4 4-1 L End 16.50 17.13 1175 1175 HDU5-SDS2.5645 0.21 4-1 R End 16.50 19.88 1165 1165 HDU5-SDS2.5645 0.21 Line 5 5-1 L End 19.50 42.13 331 331 HDU5-SDS2.5645 0.06 5-1 R End 19.50 45.88 322 322 HDU5-SDS2.5645 0.06 Line 7 7-1 L End 29.75 0.12 3672 3672 HDU5-SDS2.5645 0.65 7-1 R End 29.75 19.88 3641 3641 HDU5-SDS2.5645 0.64 Line 8 8-1 L End 35.75 26.88 1281 1281 HDU5-SDS2.5645 0.23 8-1 R End 35.75 45.88 1260 1260 HDU5-SDS2.5645 0.22 Line 11 11-1 L End 53.50 0.12 3089 3089 HDU5-SDS2.5645 0.55 11-1 R End 53.50 21.88 3098 3098 HDU5-SDS2.5645 0.55 Line 12 12-1 L End 57.50 22.13 1171 1171 HDU5-SDS2.5645 0.21 V Elem 57.50 26.13 832 832 Refer to upper level 12-1 R End 57.50 34.88 1947 1947 HDU5-SDS2.5645 0.34 Line 13 13-1 L End 63.75 35.12 2672 2672 HDU5-SDS2.5645 0.47 13-1 R End 63.75 51.88 2687 2687 HDU5-SDS2.5645 0.48 Line A A-1 L End 29.88 0.00 1129 1129 HDU5-SDS2.5645 0.20 A-1 R End 53.38 0.00 465 465 HDU5-SDS2.5645 0.08 Line B B-1 L End 0.12 17.00 2289 2289 HDU5-SDS2.5645 0.41 V Elem 9.38 17.00 1216 1216 Refer to upper level B-1 R End 16.38 17.00 577 577 HDU5-SDS2.5645 0.10 Line C C-1 L End 16.62 20.00 1025 1025 HDU5-SDS2.5645 0.18 C-1 R End 29.63 20.00 514 514 HDU5-SDS2.5645 0.09 Line D D-1 L End 29.88 22.25 3757 3757 HDU5-SDS2.5645 0.67 V Elem 49.63 22.25 2039 2039 Refer to upper level D-1 R End 53.63 22.25 4642 4642 HDU5-SDS2.5645 0.82 D-1 R End 53.63 22.00 5309 5309 HDU5-SDS2.5645 0.94 D-2 R End 57.38 22.00 -7027 Line E E-1 L End 0.12 27.00 485 485 HDU5-SDS2.5645 0.09 E-1 R End 4.38 27.00 267 267 HDU5-SDS2.5645 0.05 Line F V Elem 36.13 32.00 1942 1942 Refer to upper level V Elem 57.38 32.00 1942 1942 Refer to upper level Line G G-1 L End 57.63 35.00 1640 1640 HDU5-SDS2.5645 0.29 G-1 R End 63.63 35.00 1330 1330 HDU5-SDS2.5645 0.24 Line J J-1 L End 49.63 52.00 1759 1759 HDU5-SDS2.5645 0.31 V Elem 49.88 52.00 1227 1227 Refer to upper level J-1 R End 63.63 52.00 2329 2329 HDU5-SDS2.5645 0.41 Level 2 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 1998 1998 HDU5-SDS2. 5645 0.35 1-1 R End 0.00 22.88 1998 1998 HDU5-SDS2. 5645 0.35 Line 3 41 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 HOLD-DOWN DESIGN (rigid seismic design, continued) 3-1 L End 8.50 17.13 2265 2265 HDU5-SDS2.5645 0.40 3-1 R End 8.50 26.38 2265 2265 HDU5-SDS2. 5645 0.40 Line 4 4-1 L End 16.50 17.13 836 836 HDU5-SDS2. 5645 0.15 4-1 R End 16.50 19.88 836 836 HDU5-SDS2. 5645 0.15 Line 7 7-1 L End 29.75 0.12 2249 2249 HDU5-SDS2. 5645 0.40 7-1 R End 29.75 19.88 2249 2249 HDU5-SDS2. 5645 0.40 Line 11 11-1 L End 53.50 0.12 1452 1452 HDU5-SDS2. 5645 0.26 11-1 R End 53.50 21.88 1452 1452 HDU5-SDS2. 5645 0.26 Line 12 12-1 L End 57.50 26.13 832 832 HDU5-SDS2. 5645 0.15 12-1 R End 57.50 34.88 832 832 HDU5-SDS2. 5645 0.15 Line 13 13-1 L End 63.75 35.12 1625 1625 HDU5-SDS2. 5645 0.29 13-1 R End 63.75 51.88 1625 1625 HDU5-SDS2. 5645 0.29 Line B B-1 L End 0.12 17.00 1216 1216 HDU5-SDS2. 5645 0.22 B-1 R End 9.38 17.00 1216 1216 HDU5-SDS2. 5645 0.22 Line D D-1 L End 29.88 22.25 2039 2039 HDU5-SDS2. 5645 0.36 D-1 R End 49.63 22.25 2039 2039 HDU5-SDS2. 5645 0.36 Line F F-1 L End 36.13 32.00 1942 1942 HDU5-SDS2. 5645 0.34 F-1 R End 57.38 32.00 1942 1942 HDU5-SDS2. 5645 0.34 Line G G-1 L End 57.63 35.00 870 870 HDU5-SDS2. 5645 0.15 G-1 R End 63.63 35.00 870 870 HDU5-SDS2. 5645 0.15 Line J J-1 L End 49.88 52.00 1227 1227 HDU5-SDS2. 5645 0.22 J-1 R End 63.63 52.00 1227 1227 HDU5-SDS2. 5645 0.22 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Hold-down Forces: Shear – Seismic shear overturning component, factored for ASD by 0.7. For perforated walls, T from SDPWS 4.3-8 is used Dead – Dead load resisting component, factored for ASD by 0.60 Ev – Vertical seismic load effect from ASCE 7 12.4.2.2 = -0.2Sds x ASD seismic factor x unfactored D = 0.249 x factored D. Refer to Seismic Information table for more details. Cmb'd - Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. – Critical Response = Combined ASD force/Allowable ASD tension load Notes: Combined force from ASCE 7 2.4.1 load combination 10 = - (0.6D - 0.7Ev + 0.7Eh); Eh (from 12.4.2.1) = - shear overturning force Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. 42 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (rigid seismic design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 2 Shearline force 2580 2580 2-1 Left Wall End 4.50 27.00 -1032 994 Line 3 Shearline force 1142 1142 3-1 Right Wall End 7.75 27.25 674 -740 Line 4 Shearline force 121 121 4-1 Right Wall End 16.50 20.00 107 -104 Line 5 Shearline force 145 145 5-1 Left Wall End 19.50 42.00 -122 119 Line 8 Shearline force 3307 3307 8-1 Left Wall End 35.75 26.75 -1701 1677 8-1 Right Wall End 35.75 46.00 382 -376 Line 11 Shearline force 4868 4868 11-1 Right Wall End 53.50 22.00 2809 -2826 Line 12 Shearline force 2043 2043 12-1 Right Wall End 57.50 35.00 1158 -1102 Line C Shearline force 1857 1857 C-1 Left Wall End 16.50 20.00 -573 286 C-1 Right Wall End 29.75 20.00 825 -412 Line D Shearline force 9423 9423 D-1 Left Wall End 29.75 22.25 -4875 7987 Line E Shearline force 293 293 E-1 Right Wall End 4.50 27.00 270 -150 Line G Shearline force 667 667 G-1 Left Wall End 57.50 35.00 -596 361 Line J Shearline force 3628 3628 J-1 Right Opening 3 49.50 52.00 -1798 1149 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 1 Shearline force 1195 1195 1-1 Left Opening 1 0.00 23.00 478 -478 Line 3 Shearline force 2328 2328 3-1 Right Wall End 8.50 26.50 1443 -1443 Line 4 Shearline force 256 256 4-1 Right Wall End 16.50 20.00 225 -225 Line 7 Shearline force 3807 3807 7-1 Left Opening 1 29.75 9.50 1341 -1341 7-1 Right Opening 1 29.75 12.50 1093 -1093 Line 11 Shearline force 3025 3025 11-1 Left Opening 1 53.50 9.50 960 -960 11-1 Right Opening 1 53.50 12.50 785 -785 11-1 Right Wall End 53.50 22.00 1745 -1745 Line 12 Shearline force 809 809 12-1 Right Opening 1 57.50 26.00 -108 108 12-1 Right Wall End 57.50 35.00 458 -458 Line B Shearline force 1250 1250 B-1 Left Opening 1 9.50 17.00 530 -530 Line D Shearline force 4475 4475 43 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 COLLECTOR FORCES (rigid seismic design, continued) D-1 Left Wall End 29.75 22.25 -2315 2315 D-1 Left Opening 1 49.75 22.25 603 -603 D-1 Right Opening 1 52.75 22.25 370 -370 Line F Shearline force 4585 4585 F-1 Left Wall End 36.00 32.00 -2725 2725 Line G Shearline force 580 580 G-1 Left Wall End 57.50 35.00 -519 519 Line J Shearline force 1324 1324 J-1 Right Opening 3 49.75 52.00 -668 668 J-1 Left Opening 4 58.00 52.00 45 -45 J-1 Right Opening 4 61.00 52.00 -95 95 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force shown. For SDC C-F, it is the greater of the design shearline force and the diaphragm force Fpx, added to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength (omega) as per 12.10.1.1. Refer to Seismic Information table for diaphragm forces and omega factor. For SDC D-F, if horizontal torsional irregularities 1a or 1b are detected, or if other horizontal irregularities are input, or if vertical irregularity 4 detected or input, 25% increase from 12.3.3.4 applied. For perforated walls, this force is converted to vmax using 4.3.6.4.1.1. Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 44 WoodWorks® Shearwalls 1.wsw Jan. 16, 2021 16:54:39 45 WoodWorks® Shearwalls SOFTWARE FOR WOOD DESIGN WoodWorks® Shearwalls 2019 (Update 1) 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Project Information COMPANY AND PROJECT INFORMATION Company Project Swartz Engineering Kenneth H Swartz, PE PO Box 532 DESIGN SETTINGS Design Code IBC 2018/AWC SDPWS 2015 Wind Standard ASCE 7-16 Directional (All heights) Seismic Standard ASCE 7-16 Load Combinations For Design (ASD) 0.70 Seismic 0.60 Wind For Deflection (Strength) 1.00 Seismic 1.00 Wind Building Code Capacity Modification Wind Seismic 1.00 1.00 Service Conditions and Load Duration Duration Factor 1.60 Temperature Range T<=100F Moisture Content Fabrication Service 19% (<=19%) 10% (<=19%) Max Shearwall Offset [ft] Plan (within story) 0.50 Elevation (between stories) 1.00 Maximum Height-to-width Ratio Wood panels Wind Seismic Fiberboard Lumber Wind Seismic Gypsum Blocked Unblocked 3.5 3.5 - - - 2.0 1.5 Ignore non-wood-panel shear resistance contribution... Wind Seismic when comb'd w/ wood panels Always Forces based on... Hold-downs Applied loads Drag struts Applied loads Shearwall relative rigidity: Deflection-based stiffness of wall segments Perforated shearwall Co factor: SDPWS Equation 4.3-5 Non-identical materials and construction on the shearline: Allowed, except for material type Deflection Equation: 3-term from SDPWS 4.3-1 Drift limit for wind design: 1 / 500 story height Force-transfer strap: Continuous at top of highest opening and bottom of lowest SITE INFORMATION Risk Category Category II - All others Wind ASCE 7-16 Directional (All heights) Seismic ASCE 7-16 12.8 Equivalent Lateral Force Procedure Design Wind Speed 110 mph Exposure Exposure C Enclosure Partially open Structure Type Irregular Building System Bearing Wall Design Category D Site Class D Topographic Information [ft] Shape - Height - Length - Site Location: - Elev: 0ft Rigid building - Static analysis Spectral Response Acceleration S1: 0.600g Ss: 1.600g Fundamental Period E-W N-S T Used 0.197s 0.197s Approximate Ta 0.197s 0.197s Maximum T 0.276s 0.276s Response Factor R 6.50 6.50 Fa: 1.00 Fv: 1.70 Case 2 N-S loadsE-W loads Eccentricity (%)15 15 Loaded at 75% Min Wind Loads: Walls Roofs 16 psf 8 psf Serviceability Wind Speed 85 mph 1 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Structural Data STORY INFORMATION Hold-down Story Floor/Ceiling Wall Length subject to Bolt Elev [ft]Depth [in]Height [ft]shrinkage [in]length [in] Ceiling 22.00 0.0 Level 2 13.00 12.0 9.00 15.6 16.4 Level 1 3.00 12.0 9.00 15.6 16.4 Foundation 2.00 BLOCK and ROOF INFORMATION Block Roof Panels Dimensions [ft]Face Type Slope Overhang [ft] Block 1 2 Story E-W Ridge Location X,Y =0.00 17.00 North Side 90.0 1.50 Extent X,Y =63.75 35.00 South Side 7.0 1.50 Ridge Y Location, Offset 52.00 17.50 East Gable 90.0 1.50 Ridge Elevation, Height 26.30 4.30 West Gable 90.0 1.50 Block 2 2 Story E-W Ridge Location X,Y =29.75 0.00 North Side 90.0 1.50 Extent X,Y =27.75 17.00 South Side 7.0 1.50 Ridge Y Location, Offset 17.00 8.50 East Gable 90.0 1.50 Ridge Elevation, Height 24.09 2.09 West Gable 90.0 1.50 2 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEATHING MATERIALS by WALL GROUP Sheathing Fasteners Apply Grp Surf Material Ratng Thick GU Ply Or Gvtv Size Type Df Eg Fd Bk Notes in in lbs/in in in 1 Both Structural sheath 24/16 7/16 -3 Vert 27000 10d Nail N 2 12 Y 2,3 2 Ext Structural sheath 24/16 7/16 - 3 Vert 27000 8d Nail N 4 12 Y 2,3 3 Int Gyp WB 1-ply 48/24 1/2 - - Horz 40000 5d Nail N 7 7 N 5 4 Ext Structural sheath 24/16 7/16 - 3 Vert 27000 8d Nail N 3 12 Y 2,3 5 Ext Structural I 24/16 7/16 -3 Horz 35000 10d Nail N 2 12 Y 2,3 Legend: Grp – Wall Design Group number, used to reference wall in other tables (created by program) Surf – Exterior or interior surface when applied to exterior wall Ratng – Span rating, see SDPWS Table C4.2.2.2C Thick – Nominal panel thickness GU - Gypsum underlay thickness Ply – Number of plies (or layers) in construction of plywood sheets Or – Orientation of longer dimension of sheathing panels Gvtv – Shear stiffness in lb/in. of depth from SDPWS Tables C4.2.2A-B Type – Fastener type from SDPWS Tables 4.3A-D: Nail – common wire nail for structural panels and lumber, cooler or gypsum wallboard nail for GWB, plasterboard nail for gypsum lath, galvanised nail for gypsum sheathing; Box - box nail; Casing – casing nail; Roof – roofing nail; Screw – drywall screw Size - Common, box, and casing nails: refer to SDPWS Table A1 (casing sizes = box sizes). Gauges: 11 ga = 0.120” x 1-3/4” (gypsum sheathing, 25/32” fiberboard ), 1-1/2” (lath & plaster, 1/2” fiberboard); 13 ga plasterboard = 0.92” x 1- 1/8”. Cooler or gypsum wallboard nail: 5d = .086” x 1-5/8”; 6d = .092” x 1-7/8”; 8d = .113” x 2-3/8”; 6/8d = 6d base ply, 8d face ply for 2-ply GWB. Drywall screws: No. 6, 1-1/4” long. 5/8” gypsum sheathing can also use 6d cooler or GWB nail Df – Deformed nails ( threaded or spiral), with increased withdrawal capacity Eg – Panel edge fastener spacing Fd – Field spacing interior to panels Bk – Sheathing is nailed to blocking at all panel edges; Y(es) or N(o) Apply Notes – Notes below table legend which apply to sheathing side Notes: 2. Framing at adjoining panel edges must be 3" nominal or wider with staggered nailing according to SDPWS 4.3.7.1.4 3. Shear capacity for current design has been increased to the value for 15/32" sheathing with same nailing because stud spacing is 16" max. or panel orientation is horizontal. See SDPWS T4.3A Note 2. 5. This material does not contribute to seismic shear resistance because of the "Ignore non-wood-panel contribution for all walls" design setting. FRAMING MATERIALS and STANDARD WALL by WALL GROUP Wall Species Grade b d Spcg SG E Standard Wall Grp in in in psi^6 1 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmitted 2 2x 2 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Perforated 4 3 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Non-Shear 4 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmented 3 5 D.Fir-L Stud 1.50 5.50 16 0.50 1.40 Exterior Segmented - 2 Legend: Wall Grp – Wall Design Group b – Stud breadth (thickness) d – Stud depth (width) Spcg – Maximum on-centre spacing of studs for design, actual spacing may be less. SG – Specific gravity E – Modulus of elasticity Standard Wall - Standard wall designed as group. Notes: Check manufacture requirements for stud size, grade and specific gravity (G) for all shearwall hold-downs. 3 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEARLINE, WALL and OPENING DIMENSIONS North-south Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group X [ft] Start End [ft] [ft] Ratio [ft] Line 1 Level 2 Line 1 2 0.00 17.00 27.00 10.00 6.00 - 9.00 Wall 1-1 Prf 2 0.00 17.00 27.00 10.00 6.00 - - Segment 1 -- 17.00 23.00 6.00 6.00 1.50 - Opening 1 -- 23.00 26.00 3.00 3.00 - 5.00 Segment 2 -- 26.00 27.00 1.00 1.00 9.00 - Level 1 Line 1 Seg 1 0.00 17.00 27.00 10.00 10.00 - 9.00 Wall 1-1 Seg 1 0.00 17.00 27.00 10.00 10.00 0.90 - Line 2 Level 2 Line 2 2 4.50 17.00 42.00 25.00 0.00 - 9.00 Wall 2-1 Prf 2 4.50 27.00 42.00 15.00 0.00 - - Segment 1 -- 27.00 27.75 0.75 0.75 12.00 - Opening 1 -- 27.75 30.75 3.00 3.00 - 2.50 Segment 2 -- 30.75 32.00 1.25 1.25 7.20 - Opening 2 -- 32.00 36.50 4.50 4.50 - 8.00 Segment 3 -- 36.50 37.75 1.25 1.25 7.20 - Opening 3 -- 37.75 40.75 3.00 3.00 - 2.50 Segment 4 -- 40.75 42.00 1.25 1.25 7.20 - Level 1 Line 2 Prf 2 4.50 17.00 42.00 25.00 15.00 - 9.00 Wall 2-1 Prf 2 4.50 27.00 42.00 15.00 15.00 0.60 - Line 3 Level 2 Line 3 Prf 2 8.50 17.00 42.00 25.00 9.50 - 9.00 Wall 3-1 Prf 2 8.50 17.00 26.50 9.50 9.50 0.95 - Level 1 Line 3 Prf 2 7.75 17.00 42.00 25.00 10.25 - 9.00 Wall 3-1 Prf 2 7.75 17.00 27.25 10.25 10.25 0.88 - Line 4 Level 2 Line 4 Seg 5 16.50 17.00 42.00 25.00 3.00 - 9.00 Wall 4-1 Seg 5 16.50 17.00 20.00 3.00 3.00 3.00 - Level 1 Line 4 Seg 1 16.50 17.00 42.00 25.00 3.00 - 9.00 Wall 4-1 Seg 1 16.50 17.00 20.00 3.00 3.00 3.00 - Line 5 Level 2 Line 5 2 19.50 20.00 46.00 26.00 0.00 - 9.00 Wall 5-1 Prf 2 19.50 42.00 46.00 4.00 0.00 - - Segment 1 -- 42.00 42.75 0.75 0.75 12.00 - Opening 1 -- 42.75 45.25 2.50 2.50 - 4.50 Segment 2 -- 45.25 46.00 0.75 0.75 12.00 - Level 1 Line 5 Prf 2 19.50 20.00 46.00 26.00 3.56 - 9.00 Wall 5-1 Prf 2 19.50 42.00 46.00 4.00 3.56 2.25 - Line 6 Level 1 Line 6 NSW 22.25 32.50 40.50 8.00 0.00 - 9.00 Wall 6-1 NSW 22.25 32.50 40.50 8.00 0.00 1.13 - Line 7 Level 2 Line 7 Prf 2 29.75 20.00 46.00 26.00 0.00 - 9.00 Wall 7-1 Prf 2 29.75 20.00 22.00 2.00 0.00 4.50 - Level 1 Line 7 Seg 1 29.75 20.00 46.00 26.00 0.00 - 9.00 Wall 7-1 Seg 1 29.75 20.00 22.00 2.00 0.00 4.50 - Line 8 Level 2 Line 8 2 35.50 20.00 52.00 32.00 0.00 - 9.00 Wall 8-1 Prf 2 35.50 46.00 52.00 6.00 0.00 - - Segment 1 -- 46.00 47.50 1.50 1.50 6.00 - Opening 1 -- 47.50 50.50 3.00 3.00 - 6.67 Segment 2 -- 50.50 52.00 1.50 1.50 6.00 - Level 1 Line 8 2 35.69 20.00 52.00 32.00 25.25 - 9.00 Wall 8-1 Prf 2 35.75 26.75 46.00 19.25 19.25 0.47 - Wall 8-2 Prf 2 35.50 46.00 52.00 6.00 6.00 1.50 - Line 9 4 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Level 2 Line 9 NSW 38.00 32.00 42.25 10.25 0.00 - 9.00 Wall 9-1 NSW 38.00 32.00 42.25 10.25 0.00 0.88 - Line 10 Level 2 Line 10 50.25 32.00 52.00 20.00 0.00 - 9.00 Wall 10-1 NSW 50.25 32.00 40.00 8.00 0.00 1.00 - Wall 10-2 NSW 50.25 43.00 52.00 9.00 0.00 1.00 - Line 11 Level 2 Line 11 Prf 2 53.50 20.00 52.00 32.00 0.00 - 9.00 Wall 11-1 Prf 2 53.50 20.00 22.00 2.00 0.00 4.50 - Level 1 Line 11 Seg 1 53.50 20.00 52.00 32.00 0.00 - 9.00 Wall 11-1 Seg 1 53.50 20.00 22.00 2.00 0.00 4.50 - Line 12 Level 2 Line 12 2 57.50 22.00 52.00 30.00 9.00 - 9.00 Wall 12-1 Prf 2 57.50 22.00 35.00 13.00 9.00 - - Segment 1 -- 22.00 23.00 1.00 1.00 9.00 - Opening 1 -- 23.00 26.00 3.00 3.00 - 2.00 Segment 2 -- 26.00 35.00 9.00 9.00 1.00 - Level 1 Line 12 Seg 1 57.50 22.00 52.00 30.00 13.00 - 9.00 Wall 12-1 Seg 1 57.50 22.00 35.00 13.00 13.00 0.69 - Line 13 Level 2 Line 13 Prf 2 63.75 35.00 52.00 17.00 17.00 - 9.00 Wall 13-1 Prf 2 63.75 35.00 52.00 17.00 17.00 0.53 - Level 1 Line 13 Prf 2 63.75 35.00 52.00 17.00 17.00 - 9.00 Wall 13-1 Prf 2 63.75 35.00 52.00 17.00 17.00 0.53 - East-west Type Wall Location Extent [ft]Length FHS Aspect Height Shearlines Group Y [ft] Start End [ft] [ft] Ratio [ft] Line A Level 2 Line A 2 17.00 0.00 16.50 16.50 9.50 - 9.00 Wall A-1 Prf 2 17.00 0.00 16.50 16.50 9.50 - - Segment 1 -- 0.00 9.50 9.50 9.50 0.95 - Opening 1 -- 9.50 14.50 5.00 5.00 - 6.50 Segment 2 -- 14.50 16.50 2.00 2.00 4.50 - Level 1 Line A Seg 1 17.00 0.00 16.50 16.50 16.50 - 9.00 Wall A-1 Seg 1 17.00 0.00 16.50 16.50 16.50 0.55 - Line B Level 2 Line B 2 20.00 0.00 53.50 53.50 0.00 - 9.00 Wall B-1 Prf 2 20.00 16.50 29.75 13.25 0.00 - - Segment 1 -- 16.50 18.50 2.00 2.00 4.50 - Opening 1 -- 18.50 19.50 1.00 1.00 - 6.67 Segment 2 -- 19.50 21.50 2.00 2.00 4.50 - Opening 2 -- 21.50 24.50 3.00 3.00 - 6.67 Segment 3 -- 24.50 26.25 1.75 1.75 5.14 - Opening 3 -- 26.25 27.75 1.50 1.50 - 5.00 Segment 4 -- 27.75 29.75 2.00 2.00 4.50 - Wall B-2 Prf 2 20.00 29.75 53.50 23.75 0.00 - - Segment 1 -- 29.75 31.50 1.75 1.75 5.14 - Opening 1 -- 31.50 40.50 9.00 9.00 - 8.00 Segment 2 -- 40.50 42.50 2.00 2.00 4.50 - Opening 2 -- 42.50 51.50 9.00 9.00 - 8.00 Segment 3 -- 51.50 53.50 2.00 2.00 4.50 - Level 1 Line B 1 20.00 0.00 53.50 53.50 13.25 - 9.00 Wall B-1 Seg 1 20.00 16.50 29.75 13.25 13.25 0.68 - Wall B-2 NSW 20.00 29.75 53.50 23.75 0.00 1.00 - Line C Level 2 Line C 2 22.21 0.00 57.50 57.50 23.56 - 9.00 Wall C-1 Prf 2 22.25 29.75 53.75 24.00 20.00 - - Segment 1 -- 29.75 49.75 20.00 20.00 0.45 - Opening 1 -- 49.75 52.75 3.00 3.00 - 6.67 Segment 2 -- 52.75 53.75 1.00 1.00 9.00 - 5 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Wall C-2 Prf 2 22.00 53.50 57.50 4.00 3.56 2.25 - Level 1 Line C 1 22.21 0.00 57.50 57.50 28.00 - 9.00 Wall C-1 Seg 1 22.25 29.75 53.75 24.00 24.00 0.38 - Wall C-2 Seg 1 22.00 53.50 57.50 4.00 4.00 2.25 - Line D Level 2 Line D 2 27.00 0.00 57.50 57.50 0.00 - 9.00 Wall D-1 Prf 2 27.00 0.00 4.50 4.50 0.00 - - Segment 1 -- 0.00 1.00 1.00 1.00 9.00 - Opening 1 -- 1.00 4.00 3.00 3.00 - 5.00 Segment 2 -- 4.00 4.50 0.50 0.50 18.00 - Wall D-2 NSW 26.50 21.50 42.50 21.00 0.00 1.00 - Level 1 Line D Seg 1 27.00 0.00 57.50 57.50 4.50 - 9.00 Wall D-1 Seg 1 27.00 0.00 4.50 4.50 4.50 2.00 - Line E Level 2 Line E Prf 2 32.00 4.50 57.50 53.00 21.50 - 9.00 Wall E-1 Prf 2 32.00 36.00 57.50 21.50 21.50 0.42 - Line F Level 2 Line F Seg 4 35.00 4.50 63.75 59.25 6.25 - 9.00 Wall F-1 Seg 4 35.00 57.50 63.75 6.25 6.25 1.44 - Level 1 Line F Seg 1 35.00 4.50 63.75 59.25 6.25 - 9.00 Wall F-1 Seg 1 35.00 57.50 63.75 6.25 6.25 1.44 - Line G Level 2 Line G 2 42.00 4.50 63.75 59.25 0.00 - 9.00 Wall G-1 Prf 2 42.00 4.50 19.50 15.00 0.00 - - Segment 1 -- 4.50 6.50 2.00 2.00 4.50 - Opening 1 -- 6.50 18.50 12.00 12.00 - 6.67 Segment 2 -- 18.50 19.50 1.00 1.00 9.00 - Level 1 Line G 2 42.00 4.50 63.75 59.25 0.00 - 9.00 Wall G-1 Prf 2 42.00 4.50 19.50 15.00 0.00 - - Segment 1 -- 4.50 5.50 1.00 1.00 9.00 - Opening 1 -- 5.50 8.50 3.00 3.00 - 5.00 Segment 2 -- 8.50 10.50 2.00 2.00 4.50 - Opening 2 -- 10.50 13.50 3.00 3.00 - 6.67 Segment 3 -- 13.50 15.50 2.00 2.00 4.50 - Opening 3 -- 15.50 18.50 3.00 3.00 - 5.00 Segment 4 -- 18.50 19.50 1.00 1.00 9.00 - Line H Level 2 Line H 2 46.00 19.50 63.75 44.25 0.00 - 9.00 Wall H-1 Prf 2 46.00 19.50 35.50 16.00 0.00 - - Segment 1 -- 19.50 21.25 1.75 1.75 5.14 - Opening 1 -- 21.25 24.25 3.00 3.00 - 5.00 Segment 2 -- 24.25 24.75 0.50 0.50 18.00 - Opening 2 -- 24.75 30.75 6.00 6.00 - 5.00 Segment 3 -- 30.75 31.25 0.50 0.50 18.00 - Opening 3 -- 31.25 34.25 3.00 3.00 - 5.00 Segment 4 -- 34.25 35.50 1.25 1.25 7.20 - Level 1 Line H 2 46.00 19.50 63.75 44.25 0.00 - 9.00 Wall H-1 Prf 2 46.00 19.50 35.50 16.00 0.00 - - Segment 1 -- 19.50 21.25 1.75 1.75 5.14 - Opening 1 -- 21.25 24.25 3.00 3.00 - 5.00 Segment 2 -- 24.25 24.75 0.50 0.50 18.00 - Opening 2 -- 24.75 30.75 6.00 6.00 - 2.50 Segment 3 -- 30.75 31.25 0.50 0.50 18.00 - Opening 3 -- 31.25 34.25 3.00 3.00 - 5.00 Segment 4 -- 34.25 35.50 1.25 1.25 7.20 - Line I Level 2 Line I 2 52.00 35.50 63.75 28.25 9.93 - 9.00 Wall I-1 Prf 2 52.00 35.50 63.75 28.25 9.93 - - Segment 1 -- 35.50 36.75 1.25 1.25 7.20 - Opening 1 -- 36.75 39.75 3.00 3.00 - 5.00 Segment 2 -- 39.75 40.25 0.50 0.50 18.00 - 6 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEARLINE, WALL and OPENING DIMENSIONS (continued) Opening 2 -- 40.25 46.25 6.00 6.00 - 5.00 Segment 3 -- 46.25 46.75 0.50 0.50 18.00 - Opening 3 -- 46.75 49.75 3.00 3.00 - 5.00 Segment 4 -- 49.75 58.00 8.25 8.25 1.09 - Opening 4 -- 58.00 61.00 3.00 3.00 - 3.50 Segment 5 -- 61.00 63.75 2.75 1.68 3.27 - Level 1 Line I 2 52.00 35.50 63.75 28.25 14.25 - 9.00 Wall I-1 Prf 2 52.00 35.50 63.75 28.25 14.25 - - Segment 1 -- 35.50 36.50 1.00 1.00 9.00 - Opening 1 -- 36.50 39.50 3.00 3.00 - 2.50 Segment 2 -- 39.50 40.25 0.75 0.75 12.00 - Opening 2 -- 40.25 46.25 6.00 6.00 - 2.50 Segment 3 -- 46.25 46.50 0.25 0.25 36.00 - Opening 3 -- 46.50 49.50 3.00 3.00 - 5.00 Segment 4 -- 49.50 63.75 14.25 14.25 0.63 - Legend: Type - Seg = segmented, Prf = perforated, FT = force-transfer, NSW = non-shearwall Location - Dimension perpendicular to wall FHS - Length of full-height sheathing used to resist shear force. For perforated walls, it is based on the factored segments Li defined in SDPWS 4.3.4.3 Aspect Ratio – Ratio of wall height to segment length (h/bs), for force-transfer walls, the aspect ratio of the central pier Wall Group - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall 7 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Loads WIND SHEAR LOADS (as entered or generated) Level 2 Magnitude Trib Block F Element Load Wnd Surf Prof Location [ft][lbs,plf,psf]Ht Case Dir Dir Start End Start End [ft] Block 1 W Wall 1 W->E Wind Line 17.00 27.00 72.4 Block 1 W L Gable 1 W->E Wind Line 17.00 52.00 0.0 71.7 Block 1 W Wall Min W->E Wind Line 17.00 27.00 36.0 Block 1 W L Gable Min W->E Wind Line 17.00 52.00 0.0 34.4 Block 1 W Wall Min W->E Wind Line 27.00 42.00 36.0 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 72.4 Block 1 W Wall Min W->E Wind Line 42.00 46.00 36.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 72.4 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 72.4 Block 1 W Wall Min W->E Wind Line 46.00 52.00 36.0 Block 1 E Wall Min W->E Lee Line 17.00 20.00 36.0 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 31.7 Block 1 E L Gable Min W->E Lee Line 17.00 52.00 0.0 34.4 Block 1 E L Gable 1 W->E Lee Line 17.00 52.00 0.0 30.3 Block 1 E Wall Min W->E Lee Line 35.00 52.00 36.0 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 31.7 Block 1 W Wall Min E->W Lee Line 17.00 27.00 36.0 Block 1 W L Gable Min E->W Lee Line 17.00 52.00 0.0 34.4 Block 1 W L Gable 1 E->W Lee Line 17.00 52.00 0.0 30.3 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 31.7 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 31.7 Block 1 W Wall Min E->W Lee Line 27.00 42.00 36.0 Block 1 W Wall Min E->W Lee Line 42.00 46.00 36.0 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 31.7 Block 1 W Wall Min E->W Lee Line 46.00 52.00 36.0 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 31.7 Block 1 E L Gable 1 E->W Wind Line 17.00 52.00 0.0 71.7 Block 1 E L Gable Min E->W Wind Line 17.00 52.00 0.0 34.4 Block 1 E Wall 1 E->W Wind Line 17.00 20.00 72.4 Block 1 E Wall Min E->W Wind Line 17.00 20.00 36.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 72.4 Block 1 E Wall Min E->W Wind Line 35.00 52.00 36.0 Block 1 S Roof Min S->N Wind Line -1.50 65.25 294.2 Block 1 S Wall Min S->N Wind Line 0.00 16.50 36.0 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 72.4 Block 1 S Wall Min S->N Wind Line 16.50 29.75 36.0 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 72.4 Block 1 N Roof Min S->N Lee Line -1.50 65.25 17.2 Block 1 N Roof 1 S->N Lee Line -1.50 65.25 54.2 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 47.3 Block 1 N Wall Min S->N Lee Line 0.00 4.50 36.0 Block 1 N Wall Min S->N Lee Line 4.50 19.50 36.0 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 47.3 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 47.3 Block 1 N Wall Min S->N Lee Line 19.50 35.50 36.0 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 47.3 Block 1 N Wall Min S->N Lee Line 35.50 63.75 36.0 Block 1 S Roof Min N->S Lee Line -1.50 65.25 294.2 Block 1 S Wall Min N->S Lee Line 0.00 16.50 36.0 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 46.3 Block 1 S Wall Min N->S Lee Line 16.50 29.75 36.0 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 46.3 Block 1 N Roof 1 N->S Wind Line -1.50 65.25 72.2 Block 1 N Roof Min N->S Wind Line -1.50 65.25 17.2 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 72.4 Block 1 N Wall Min N->S Wind Line 0.00 4.50 36.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 72.4 Block 1 N Wall Min N->S Wind Line 4.50 19.50 36.0 Block 1 N Wall Min N->S Wind Line 19.50 35.50 36.0 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 72.4 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 72.4 Block 1 N Wall Min N->S Wind Line 35.50 63.75 36.0 Block 2 W L Gable Min W->E Wind Line 0.00 17.00 0.0 16.7 Block 2 W L Gable 1 W->E Wind Line 0.00 17.00 0.0 34.6 Block 2 E L Gable 1 W->E Lee Line 0.00 17.00 0.0 16.2 Block 2 E L Gable Min W->E Lee Line 0.00 17.00 0.0 16.7 Block 2 E Wall 1 W->E Lee Line 20.00 22.00 35.0 Block 2 E Wall Min W->E Lee Line 20.00 22.00 36.0 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 35.0 8 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 WIND SHEAR LOADS (as entered or generated) (continued) Block 2 E Wall Min W->E Lee Line 22.00 35.00 36.0 Block 2 W L Gable 1 E->W Lee Line 0.00 17.00 0.0 16.2 Block 2 W L Gable Min E->W Lee Line 0.00 17.00 0.0 16.7 Block 2 E L Gable 1 E->W Wind Line 0.00 17.00 0.0 34.6 Block 2 E L Gable Min E->W Wind Line 0.00 17.00 0.0 16.7 Block 2 E Wall 1 E->W Wind Line 20.00 22.00 72.4 Block 2 E Wall Min E->W Wind Line 20.00 22.00 36.0 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 72.4 Block 2 E Wall Min E->W Wind Line 22.00 35.00 36.0 Block 2 S Roof Min S->N Wind Line 28.25 59.00 149.1 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 72.4 Block 2 S Wall Min S->N Wind Line 29.75 53.50 36.0 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 72.4 Block 2 S Wall Min S->N Wind Line 53.50 57.50 36.0 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 72.4 Block 2 S Wall Min S->N Wind Line 57.50 63.75 36.0 Block 2 N Roof 1 S->N Lee Line 28.25 59.00 26.0 Block 2 N Roof Min S->N Lee Line 28.25 59.00 8.3 Block 2 S Roof Min N->S Lee Line 28.25 59.00 149.1 Block 2 S Wall Min N->S Lee Line 29.75 53.50 36.0 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 46.3 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 46.3 Block 2 S Wall Min N->S Lee Line 53.50 57.50 36.0 Block 2 S Wall Min N->S Lee Line 57.50 63.75 36.0 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 46.3 Block 2 N Roof 1 N->S Wind Line 28.25 59.00 34.7 Block 2 N Roof Min N->S Wind Line 28.25 59.00 8.3 Level 1 Magnitude Trib Block F Element Load Wnd Surf Prof Location [ft][lbs,plf,psf]Ht Case Dir Dir Start End Start End [ft] Block 1 W Wall 1 W->E Wind Line 17.00 27.00 83.6 Block 1 W Wall Min W->E Wind Line 17.00 27.00 36.0 Block 1 W Wall Min W->E Wind Line 17.00 27.00 44.0 Block 1 W Wall 1 W->E Wind Line 17.00 27.00 69.0 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 83.6 Block 1 W Wall Min W->E Wind Line 27.00 42.00 44.0 Block 1 W Wall Min W->E Wind Line 27.00 42.00 36.0 Block 1 W Wall 1 W->E Wind Line 27.00 42.00 69.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 83.6 Block 1 W Wall Min W->E Wind Line 42.00 46.00 36.0 Block 1 W Wall 1 W->E Wind Line 42.00 46.00 69.0 Block 1 W Wall Min W->E Wind Line 42.00 46.00 44.0 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 83.6 Block 1 W Wall Min W->E Wind Line 46.00 52.00 36.0 Block 1 W Wall 1 W->E Wind Line 46.00 52.00 69.0 Block 1 W Wall Min W->E Wind Line 46.00 52.00 44.0 Block 1 E Wall Min W->E Lee Line 17.00 20.00 36.0 Block 1 E Wall Min W->E Lee Line 17.00 20.00 44.0 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 31.7 Block 1 E Wall 1 W->E Lee Line 17.00 20.00 38.8 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 31.7 Block 1 E Wall 1 W->E Lee Line 35.00 52.00 38.8 Block 1 E Wall Min W->E Lee Line 35.00 52.00 36.0 Block 1 E Wall Min W->E Lee Line 35.00 52.00 44.0 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 31.7 Block 1 W Wall 1 E->W Lee Line 17.00 27.00 38.8 Block 1 W Wall Min E->W Lee Line 17.00 27.00 44.0 Block 1 W Wall Min E->W Lee Line 17.00 27.00 36.0 Block 1 W Wall Min E->W Lee Line 27.00 42.00 44.0 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 38.8 Block 1 W Wall Min E->W Lee Line 27.00 42.00 36.0 Block 1 W Wall 1 E->W Lee Line 27.00 42.00 31.7 Block 1 W Wall Min E->W Lee Line 42.00 46.00 36.0 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 31.7 Block 1 W Wall Min E->W Lee Line 42.00 46.00 44.0 Block 1 W Wall 1 E->W Lee Line 42.00 46.00 38.8 Block 1 W Wall Min E->W Lee Line 46.00 52.00 44.0 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 31.7 Block 1 W Wall 1 E->W Lee Line 46.00 52.00 38.8 Block 1 W Wall Min E->W Lee Line 46.00 52.00 36.0 Block 1 E Wall Min E->W Wind Line 17.00 20.00 36.0 Block 1 E Wall 1 E->W Wind Line 17.00 20.00 83.6 Block 1 E Wall Min E->W Wind Line 17.00 20.00 44.0 9 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 WIND SHEAR LOADS (as entered or generated) (continued) Block 1 E Wall 1 E->W Wind Line 17.00 20.00 69.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 69.0 Block 1 E Wall Min E->W Wind Line 35.00 52.00 44.0 Block 1 E Wall 1 E->W Wind Line 35.00 52.00 83.6 Block 1 E Wall Min E->W Wind Line 35.00 52.00 36.0 Block 1 S Wall Min S->N Wind Line 0.00 16.50 36.0 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 69.0 Block 1 S Wall Min S->N Wind Line 0.00 16.50 44.0 Block 1 S Wall 1 S->N Wind Line 0.00 16.50 83.6 Block 1 S Wall Min S->N Wind Line 16.50 29.75 36.0 Block 1 S Wall Min S->N Wind Line 16.50 29.75 44.0 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 83.6 Block 1 S Wall 1 S->N Wind Line 16.50 29.75 69.0 Block 1 N Wall Min S->N Lee Line 0.00 4.50 44.0 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 47.3 Block 1 N Wall Min S->N Lee Line 0.00 4.50 36.0 Block 1 N Wall 1 S->N Lee Line 0.00 4.50 57.8 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 57.8 Block 1 N Wall Min S->N Lee Line 4.50 19.50 36.0 Block 1 N Wall 1 S->N Lee Line 4.50 19.50 47.3 Block 1 N Wall Min S->N Lee Line 4.50 19.50 44.0 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 47.3 Block 1 N Wall Min S->N Lee Line 19.50 35.50 36.0 Block 1 N Wall Min S->N Lee Line 19.50 35.50 44.0 Block 1 N Wall 1 S->N Lee Line 19.50 35.50 57.8 Block 1 N Wall Min S->N Lee Line 35.50 63.75 44.0 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 57.8 Block 1 N Wall 1 S->N Lee Line 35.50 63.75 47.3 Block 1 N Wall Min S->N Lee Line 35.50 63.75 36.0 Block 1 S Wall Min N->S Lee Line 0.00 16.50 36.0 Block 1 S Wall Min N->S Lee Line 0.00 16.50 44.0 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 56.6 Block 1 S Wall 1 N->S Lee Line 0.00 16.50 46.3 Block 1 S Wall Min N->S Lee Line 16.50 29.75 36.0 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 56.6 Block 1 S Wall Min N->S Lee Line 16.50 29.75 44.0 Block 1 S Wall 1 N->S Lee Line 16.50 29.75 46.3 Block 1 N Wall Min N->S Wind Line 0.00 4.50 36.0 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 69.0 Block 1 N Wall 1 N->S Wind Line 0.00 4.50 83.6 Block 1 N Wall Min N->S Wind Line 0.00 4.50 44.0 Block 1 N Wall Min N->S Wind Line 4.50 19.50 44.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 69.0 Block 1 N Wall Min N->S Wind Line 4.50 19.50 36.0 Block 1 N Wall 1 N->S Wind Line 4.50 19.50 83.6 Block 1 N Wall Min N->S Wind Line 19.50 35.50 44.0 Block 1 N Wall Min N->S Wind Line 19.50 35.50 36.0 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 69.0 Block 1 N Wall 1 N->S Wind Line 19.50 35.50 83.6 Block 1 N Wall Min N->S Wind Line 35.50 63.75 44.0 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 69.0 Block 1 N Wall 1 N->S Wind Line 35.50 63.75 83.6 Block 1 N Wall Min N->S Wind Line 35.50 63.75 36.0 Block 2 E Wall Min W->E Lee Line 20.00 22.00 36.0 Block 2 E Wall Min W->E Lee Line 20.00 22.00 44.0 Block 2 E Wall 1 W->E Lee Line 20.00 22.00 35.0 Block 2 E Wall 1 W->E Lee Line 20.00 22.00 42.7 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 42.7 Block 2 E Wall Min W->E Lee Line 22.00 35.00 44.0 Block 2 E Wall 1 W->E Lee Line 22.00 35.00 35.0 Block 2 E Wall Min W->E Lee Line 22.00 35.00 36.0 Block 2 E Wall 1 E->W Wind Line 20.00 22.00 69.0 Block 2 E Wall 1 E->W Wind Line 20.00 22.00 83.6 Block 2 E Wall Min E->W Wind Line 20.00 22.00 36.0 Block 2 E Wall Min E->W Wind Line 20.00 22.00 44.0 Block 2 E Wall Min E->W Wind Line 22.00 35.00 36.0 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 83.6 Block 2 E Wall 1 E->W Wind Line 22.00 35.00 69.0 Block 2 E Wall Min E->W Wind Line 22.00 35.00 44.0 Block 2 S Wall Min S->N Wind Line 29.75 53.50 44.0 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 83.6 Block 2 S Wall 1 S->N Wind Line 29.75 53.50 69.0 Block 2 S Wall Min S->N Wind Line 29.75 53.50 36.0 10 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 WIND SHEAR LOADS (as entered or generated) (continued) Block 2 S Wall Min S->N Wind Line 53.50 57.50 36.0 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 83.6 Block 2 S Wall 1 S->N Wind Line 53.50 57.50 69.0 Block 2 S Wall Min S->N Wind Line 53.50 57.50 44.0 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 69.0 Block 2 S Wall Min S->N Wind Line 57.50 63.75 36.0 Block 2 S Wall Min S->N Wind Line 57.50 63.75 44.0 Block 2 S Wall 1 S->N Wind Line 57.50 63.75 83.6 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 56.6 Block 2 S Wall 1 N->S Lee Line 29.75 53.50 46.3 Block 2 S Wall Min N->S Lee Line 29.75 53.50 44.0 Block 2 S Wall Min N->S Lee Line 29.75 53.50 36.0 Block 2 S Wall Min N->S Lee Line 53.50 57.50 36.0 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 56.6 Block 2 S Wall Min N->S Lee Line 53.50 57.50 44.0 Block 2 S Wall 1 N->S Lee Line 53.50 57.50 46.3 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 46.3 Block 2 S Wall 1 N->S Lee Line 57.50 63.75 56.6 Block 2 S Wall Min N->S Lee Line 57.50 63.75 44.0 Block 2 S Wall Min N->S Lee Line 57.50 63.75 36.0 Legend: Block - Block used in load generation Accum. = loads from one block combined with another Manual = user-entered loads (so no block) F - Building face (north, south, east or west) Element - Building surface on which loads generated or entered Load Case - One of the following: ASCE 7 All Heights: Case 1 or 2 from Fig 27.3-8 or minimum loads from 27.1.5 ASCE 7 Low-rise: Reference corner and Case A or B from Fig 28.3-1 or minimum loads from 28.3.4 Wind Dir - Direction of wind for loads with positive magnitude, also direction of MWFRS. Surf Dir - Windward or leeward side of the building for loads in given direction Prof - Profile (distribution) Location - Start and end points on building element Magnitude - Start = intensity of uniform and point loads or leftmost intensity of trapezoidal load, End = right intensity of trap load Trib Ht - Tributary height of area loads only Notes: Windward load on the monoslope roof was not generated, to comply with ASCE 7 Figure 27.3-1, Note 7. All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.60 to wind loads before distributing them to the shearlines. 11 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 BUILDING MASSES Level 2 Magnitude Trib Force Building Block Wall Profile Location [ft][lbs,plf,psf]Width Dir Element Line Start End Start End [ft] E-W Roof Block 1 1 Line 15.50 53.50 500.6 500.6 E-W Roof Block 1 13 Line 15.50 53.50 500.6 500.6 E-W Roof Block 2 7 Line -1.50 18.50 230.6 230.6 E-W Roof Block 2 12 Line -1.50 18.50 230.6 230.6 E-W R Gable Block 1 1 Line 17.00 52.00 43.0 0.0 E-W L Gable Block 1 1 Line 52.00 52.00 0.0 43.0 E-W L Gable Block 1 13 Line 17.00 52.00 43.0 0.0 E-W R Gable Block 1 13 Line 52.00 52.00 0.0 43.0 E-W R Gable Block 2 7 Line 0.00 17.00 20.9 0.0 E-W L Gable Block 2 7 Line 17.00 17.00 0.0 20.9 E-W L Gable Block 2 12 Line 0.00 17.00 20.9 0.0 E-W R Gable Block 2 12 Line 17.00 17.00 0.0 20.9 N-S Roof Block 1 A Line -1.50 65.25 285.0 285.0 N-S Roof Block 1 I Line -1.50 65.25 285.0 285.0 N-S Roof Block 2 Line 28.25 59.00 150.0 150.0 N-S Roof Block 2 A Line 28.25 59.00 150.0 150.0 Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 Both Wall 3-1 n/a Line 17.00 26.50 27.0 27.0 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 Both Wall 7-1 n/a 7 Line 20.00 22.00 27.0 27.0 Both Wall 8-1 n/a 8 Line 46.00 52.00 45.0 45.0 Both Wall 9-1 n/a 9 Line 32.00 42.25 27.0 27.0 Both Wall 10-1 n/a 10 Line 32.00 40.00 27.0 27.0 Both Wall 10-2 n/a 10 Line 43.00 52.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 20.00 22.00 45.0 45.0 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 Both Wall A-1 n/a A Line 0.00 16.50 45.0 45.0 Both Wall B-1 n/a B Line 16.50 29.75 45.0 45.0 Both Wall B-2 n/a B Line 29.75 53.50 45.0 45.0 Both Wall C-2 n/a C Line 53.50 57.50 45.0 45.0 Both Wall C-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall D-2 n/a Line 21.50 42.50 27.0 27.0 Both Wall D-1 n/a D Line 0.00 4.50 45.0 45.0 Both Wall E-1 n/a E Line 36.00 57.50 27.0 27.0 Both Wall F-1 n/a F Line 57.50 63.75 45.0 45.0 Both Wall G-1 n/a G Line 4.50 19.50 45.0 45.0 Both Wall H-1 n/a H Line 19.50 35.50 45.0 45.0 Both Wall I-1 n/a I Line 35.50 63.75 45.0 45.0 Level 1 Magnitude Trib Force Building Block Wall Profile Location [ft][lbs,plf,psf]Width Dir Element Line Start End Start End [ft] Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 E-W Floor F1 n/a 1 Line 17.00 20.00 82.5 82.5 E-W Floor F2 n/a 1 Line 20.00 22.00 267.5 267.5 E-W Floor F3 n/a 1 Line 22.00 27.00 287.5 287.5 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 E-W Floor F4 n/a 2 Line 27.00 35.00 265.0 265.0 E-W Floor F5 n/a 2 Line 35.00 42.00 296.3 296.3 Both Wall 3-1 n/a Line 17.00 26.50 27.0 27.0 E-W Floor F1 n/a 4 Line 17.00 20.00 82.5 82.5 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 E-W Floor F6 n/a 5 Line 42.00 46.00 221.3 221.3 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 Both Wall 7-1 n/a 7 Line 20.00 22.00 27.0 27.0 E-W Floor F7 n/a 8 Line 46.00 52.00 141.3 141.3 12 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 BUILDING MASSES (continued) Both Wall 8-1 n/a 8 Line 46.00 52.00 45.0 45.0 Both Wall 9-1 n/a 9 Line 32.00 42.25 27.0 27.0 Both Wall 10-1 n/a 10 Line 32.00 40.00 27.0 27.0 Both Wall 10-2 n/a 10 Line 43.00 52.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 20.00 22.00 45.0 45.0 E-W Floor F2 n/a 11 Line 20.00 22.00 267.5 267.5 E-W Floor F3 n/a 12 Line 22.00 27.00 287.5 287.5 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 E-W Floor F4 n/a 12 Line 27.00 35.00 265.0 265.0 Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 E-W Floor F5 n/a 13 Line 35.00 42.00 296.3 296.3 E-W Floor F6 n/a 13 Line 42.00 46.00 221.3 221.3 E-W Floor F7 n/a 13 Line 46.00 52.00 141.3 141.3 Both Wall A-1 n/a A Line 0.00 16.50 45.0 45.0 N-S Floor F1 n/a A Line 0.00 4.50 50.0 50.0 N-S Floor F2 n/a A Line 4.50 16.50 125.0 125.0 Both Wall B-1 n/a B Line 16.50 29.75 45.0 45.0 N-S Floor F3 n/a B Line 16.50 19.50 110.0 110.0 N-S Floor F4 n/a B Line 19.50 35.50 130.0 130.0 Both Wall B-2 n/a B Line 29.75 53.50 45.0 45.0 N-S Floor F5 n/a B Line 35.50 53.50 160.0 160.0 Both Wall C-2 n/a C Line 53.50 57.50 45.0 45.0 N-S Floor F6 n/a C Line 53.50 57.50 150.0 150.0 Both Wall C-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall D-2 n/a Line 21.50 42.50 27.0 27.0 Both Wall D-1 n/a D Line 0.00 4.50 45.0 45.0 N-S Floor F1 n/a D Line 0.00 4.50 50.0 50.0 Both Wall E-1 n/a E Line 36.00 57.50 27.0 27.0 Both Wall F-1 n/a F Line 57.50 63.75 45.0 45.0 N-S Floor F7 n/a F Line 57.50 63.75 85.0 85.0 Both Wall G-1 n/a G Line 4.50 19.50 45.0 45.0 N-S Floor F2 n/a G Line 4.50 16.50 125.0 125.0 N-S Floor F3 n/a G Line 16.50 19.50 110.0 110.0 Both Wall H-1 n/a H Line 19.50 35.50 45.0 45.0 N-S Floor F4 n/a H Line 19.50 35.50 130.0 130.0 Both Wall I-1 n/a I Line 35.50 63.75 45.0 45.0 N-S Floor F5 n/a I Line 35.50 53.50 160.0 160.0 N-S Floor F6 n/a I Line 53.50 57.50 150.0 150.0 N-S Floor F7 n/a I Line 57.50 63.75 85.0 85.0 Both Wall 1-1 n/a 1 Line 17.00 27.00 45.0 45.0 Both Wall 2-1 n/a 2 Line 27.00 42.00 45.0 45.0 Both Wall 3-1 n/a 3 Line 17.00 27.25 27.0 27.0 Both Wall 4-1 n/a 4 Line 17.00 20.00 45.0 45.0 Both Wall 5-1 n/a 5 Line 42.00 46.00 45.0 45.0 Both Wall 6-1 n/a 6 Line 32.50 40.50 27.0 27.0 Both Wall 7-1 n/a 7 Line 20.00 22.00 27.0 27.0 Both Wall 8-2 n/a 8 Line 46.00 52.00 45.0 45.0 Both Wall 8-1 n/a Line 26.75 46.00 27.0 27.0 Both Wall 11-1 n/a 11 Line 20.00 22.00 45.0 45.0 Both Wall 12-1 n/a 12 Line 22.00 35.00 45.0 45.0 13 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 BUILDING MASSES (continued) Both Wall 13-1 n/a 13 Line 35.00 52.00 45.0 45.0 Both Wall A-1 n/a A Line 0.00 16.50 45.0 45.0 Both Wall B-1 n/a B Line 16.50 29.75 45.0 45.0 Both Wall B-2 n/a B Line 29.75 53.50 45.0 45.0 Both Wall C-2 n/a C Line 53.50 57.50 45.0 45.0 Both Wall C-1 n/a Line 29.75 53.75 27.0 27.0 Both Wall D-1 n/a D Line 0.00 4.50 45.0 45.0 Both Wall F-1 n/a F Line 57.50 63.75 45.0 45.0 Both Wall G-1 n/a G Line 4.50 19.50 45.0 45.0 Both Wall H-1 n/a H Line 19.50 35.50 45.0 45.0 Both Wall I-1 n/a I Line 35.50 63.75 45.0 45.0 Legend: Force Dir - Direction in which the mass is used for seismic load generation, E-W, N-S, or Both Building element - Roof, gable end, wall or floor area used to generate mass, wall line for user-applied masses, Floor F# - refer to Plan View for floor area number Wall line - Shearline that equivalent line load is assigned to Location - Start and end points of equivalent line load on wall line Trib Width. - Tributary width; for user applied area loads only 14 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SEISMIC LOADS Level 2 Force Profile Location [ft]Mag [lbs,plf,psf] Dir Start End Start End E-W Line -1.50 0.00 92.7 92.7 E-W Line 0.00 15.50 92.7 100.4 E-W Line 15.50 17.00 301.7 302.5 E-W Point 17.00 17.00 149 149 E-W Line 17.00 18.50 326.0 318.3 E-W Line 18.50 20.00 225.6 226.3 E-W Point 20.00 20.00 335 335 E-W Line 20.00 22.00 231.8 232.8 E-W Point 22.00 22.00 36 36 E-W Line 22.00 26.50 227.3 229.6 E-W Point 22.25 22.25 130 130 E-W Point 26.50 26.50 114 114 E-W Line 26.50 27.00 224.1 224.4 E-W Point 27.00 27.00 41 41 E-W Line 27.00 32.00 224.4 226.8 E-W Point 32.00 32.00 117 117 E-W Line 32.00 35.00 237.7 239.2 E-W Point 35.00 35.00 57 57 E-W Line 35.00 40.00 239.2 241.6 E-W Line 40.00 42.00 236.2 237.2 E-W Point 42.00 42.00 136 136 E-W Line 42.00 42.25 237.2 237.3 E-W Line 42.25 43.00 231.9 232.3 E-W Line 43.00 46.00 237.7 239.2 E-W Point 46.00 46.00 145 145 E-W Line 46.00 52.00 239.2 242.1 E-W Point 52.00 52.00 256 256 E-W Line 52.00 53.50 218.6 201.3 N-S Line -1.50 0.00 114.6 114.6 N-S Point 0.00 0.00 242 242 N-S Line 0.00 4.50 132.7 132.7 N-S Point 4.50 4.50 136 136 N-S Line 4.50 16.50 132.7 132.7 N-S Point 8.50 8.50 52 52 N-S Point 16.50 16.50 27 27 N-S Line 16.50 19.50 132.7 132.7 N-S Point 19.50 19.50 36 36 N-S Line 19.50 21.50 132.7 132.7 N-S Line 21.50 28.25 138.1 138.1 N-S Line 28.25 29.75 198.5 198.5 N-S Point 29.75 29.75 47 47 N-S Line 29.75 35.50 203.9 203.9 N-S Point 35.50 35.50 54 54 N-S Line 35.50 36.00 203.9 203.9 N-S Line 36.00 42.50 209.3 209.3 N-S Point 38.00 38.00 56 56 N-S Line 42.50 53.50 203.9 203.9 N-S Point 50.25 50.25 92 92 N-S Point 53.50 53.50 18 18 N-S Line 53.50 53.75 203.9 203.9 N-S Line 53.75 57.50 198.5 198.5 N-S Point 57.50 57.50 153 153 N-S Line 57.50 59.00 193.0 193.0 N-S Line 59.00 63.75 132.7 132.7 N-S Point 63.75 63.75 305 305 N-S Line 63.75 65.25 114.6 114.6 Level 1 Force Profile Location [ft]Mag [lbs,plf,psf] Dir Start End Start End E-W Point 17.00 17.00 157 157 E-W Line 17.00 20.00 42.2 42.2 E-W Point 20.00 20.00 352 352 E-W Line 20.00 22.00 87.1 87.1 E-W Point 22.00 22.00 38 38 E-W Line 22.00 26.50 85.6 85.6 E-W Point 22.25 22.25 137 137 E-W Point 26.50 26.50 60 60 E-W Line 26.50 26.75 82.8 82.8 15 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SEISMIC LOADS (continued) E-W Line 26.75 27.00 85.6 85.6 E-W Point 27.00 27.00 43 43 E-W Line 27.00 27.25 80.9 80.9 E-W Line 27.25 32.00 78.0 78.0 E-W Point 32.00 32.00 1651 1651 E-W Point 32.00 32.00 4806 4806 E-W Point 32.00 32.00 4806 4806 E-W Point 32.00 32.00 61 61 E-W Line 32.00 32.50 83.7 83.7 E-W Line 32.50 35.00 86.6 86.6 E-W Point 35.00 35.00 60 60 E-W Line 35.00 40.00 93.2 93.2 E-W Line 40.00 40.50 90.3 90.3 E-W Line 40.50 42.00 87.5 87.5 E-W Point 42.00 42.00 143 143 E-W Line 42.00 42.25 71.6 71.6 E-W Line 42.25 43.00 68.7 68.7 E-W Line 43.00 46.00 71.6 71.6 E-W Point 46.00 46.00 152 152 E-W Line 46.00 52.00 51.8 51.8 E-W Point 52.00 52.00 269 269 N-S Point 0.00 0.00 95 95 N-S Line 0.00 4.50 29.6 29.6 N-S Point 4.50 4.50 143 143 N-S Line 4.50 16.50 45.5 45.5 N-S Point 7.75 7.75 29 29 N-S Point 8.50 8.50 27 27 N-S Point 16.50 16.50 29 29 N-S Line 16.50 19.50 42.3 42.3 N-S Point 19.50 19.50 38 38 N-S Line 19.50 21.50 46.6 46.6 N-S Line 21.50 29.75 49.4 49.4 N-S Point 22.25 22.25 23 23 N-S Point 29.75 29.75 11 11 N-S Line 29.75 35.50 55.1 55.1 N-S Point 35.50 35.50 57 57 N-S Line 35.50 36.00 61.5 61.5 N-S Point 35.75 35.75 55 55 N-S Line 36.00 42.50 64.3 64.3 N-S Point 38.00 38.00 29 29 N-S Line 42.50 53.50 61.5 61.5 N-S Point 50.25 50.25 49 49 N-S Point 53.50 53.50 19 19 N-S Line 53.50 53.75 59.4 59.4 N-S Line 53.75 57.50 53.7 53.7 N-S Point 57.50 57.50 124 124 N-S Line 57.50 63.75 37.0 37.0 N-S Point 63.75 63.75 162 162 Legend: Loads in table can be accumulation of loads from several building masses, so they do not correspond with a particular building element. Location - Start and end of load in direction perpendicular to seismic force direction Notes: All loads entered by the user or generated by program are specified (unfactored) loads.The program applies a load factor of 0.70 and redundancy factor to seismic loads before distributing them to the shearlines. 16 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Design Summary SHEARWALL DESIGN Wind Shear Loads, Flexible Diaphragm The following under-capacity shearlines were found: Level 1: 4-1 Level 2: 4-1, 12-1 Wind Shear Loads, Rigid Diaphragm The following under-capacity shearlines were found: Level 2: 3-1 Components and Cladding Wind Loads, Out-of-plane Sheathing The following under-capacity shearlines were found: Components and Cladding Wind Loads, Nail Withdrawal All shearwalls have sufficient design capacity. Seismic Loads, Flexible Diaphragm The following under-capacity shearlines were found: Level 1: 4-1 Level 2: 4-1, 12-1 Seismic Loads, Rigid Diaphragm The following under-capacity shearlines were found: Level 2: 3-1 HOLDDOWN DESIGN Wind Loads, Flexible Diaphragm Under-capacity hold-downs were found on the following walls: Level 1: F-1, 4-1, 12-1 Level 2: 4-1, 12-1 Wind Loads, Rigid Diaphragm Under-capacity hold-downs were found on the following walls: Level 1: 1-1, 3-1, 12-1, 13-1 Seismic Loads, Flexible Diaphragm Under-capacity hold-downs were found on the following walls: Level 1: F-1, 4-1, 12-1 Level 2: 4-1 Seismic Loads, Rigid Diaphragm All hold-downs have sufficient design capacity. Refer to the Deflection table for possible issues regarding fastener slippage (SDPWS Table C4.2.2D) for walls that otherwise pass. 17 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Flexible Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 209.6 209.6 1258 - 1.0 - 532 1.00 532 3192 0.39 Level 1 Ln1, Lev1 1 Both 147.4 - 1474 1.0 1.0 896 896 - A 1792 17920 0.08 Line 2 Ln2, Lev1 2 S->N 39.9 39.9 599 - 1.0 - 532 1.00 532 7980 0.08 2 N->S 39.6 39.6 594 - 1.0 - 532 1.00 532 7980 0.07 Line 3 Level 2 Ln3, Lev2 2 Both 199.8 199.8 1898 - 1.0 - 532 1.00 532 5054 0.38 Level 1 Ln3, Lev1 2 Both 241.3 241.3 2474 - 1.0 - 532 1.00 532 5453 0.45 Line 4 Level 2 Ln4, Lev2 - Both - - 6621 - - - - - - 2683 - Wall 4-1 5^Both 2207.2 - 6621 - .88 - 1022 - 894 2683 2.47* Level 1 Ln4, Lev1 - Both - - 7185 - - - - - - 4704 - Wall 4-1 1^Both 2395.2 - 7185 .88 .88 896 896 - A 1568 4704 1.53* Line 5 Ln5, Lev1 2 S->N 370.8 370.8 1483 - 1.0 - 532 1.00 532 1892 0.70 2 N->S 367.9 367.9 1471 - 1.0 - 532 1.00 532 1892 0.69 Line 8 Ln8, Lev1 - S->N - - 2937 - - - - - - 13433 - - N->S - - 2914 - - - - - - 13433 - Wall 8-1 2 S->N 152.6 152.6 2937 - 1.0 - 532 1.00 532 10241 0.29 2 N->S 151.4 151.4 2914 - 1.0 - 532 1.00 532 10241 0.28 Wall 8-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 3192 0.00 Line 12 Level 2 Ln12, Lev2 2^Both 815.2 815.2 7337 - 1.0 - 532 1.00 532 4788 1.53* Level 1 Ln12, Lev1 - Both - - 8684 - - - - - - 23296 - * Wall 12-1 1 Both 668.0 - 8684 1.0 1.0 896 896 - A 1792 23296 0.37 Line 13 Level 2 Ln13, Lev2 2 Both 59.8 59.8 1016 - 1.0 - 532 1.00 532 9044 0.11 Level 1 Ln13, Lev1 2 Both 77.4 77.4 1316 - 1.0 - 532 1.00 532 9044 0.15 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 2 W->E 45.4 45.4 431 - 1.0 - 532 1.00 532 5054 0.09 2 E->W 45.3 45.3 430 - 1.0 - 532 1.00 532 5054 0.09 Level 1 LnA, Lev1 1 W->E 38.3 - 632 1.0 1.0 896 896 - A 1792 29568 0.02 1 E->W 38.2 - 631 1.0 1.0 896 896 - A 1792 29568 0.02 Line B LnB, Lev1 - W->E - - 354 - - - - - - 23744 - - E->W - - 349 - - - - - - 23744 - Wall B-1 1 W->E 26.7 - 354 1.0 1.0 896 896 - A 1792 23744 0.01 1 E->W 26.3 - 349 1.0 1.0 896 896 - A 1792 23744 0.01 Line C Level 2 LnC, Lev2 - W->E - - 570 - - - - - - 12532 - - E->W - - 557 - - - - - - 12532 - Wall C-1 2 W->E 28.5 28.5 570 - 1.0 - 532 1.00 532 10640 0.05 2 E->W 27.9 27.9 557 - 1.0 - 532 1.00 532 10640 0.05 Wall C-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 1892 0.00 Level 1 LnC, Lev1 - W->E - - 1054 - - - - - - 49952 - - E->W - - 1026 - - - - - - 49952 - 18 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (flexible wind design, continued) Wall C-1 1 W->E 32.9 - 790 1.0 1.0 896 896 - A 1792 43008 0.02 1 E->W 42.7 - 1026 1.0 1.0 896 896 - A 1792 43008 0.02 Wall C-2 1 W->E 65.8 - 263 .97 .97 896 896 - A 1736 6944 0.04 1 E->W 0.0 - 0 .97 .97 896 896 - A 1736 6944 0.00 Line D LnD, Lev1 - W->E - - 1091 - - - - - - 8064 - - E->W - - 1059 - - - - - - 8064 - Wall D-1 1 W->E 242.5 - 1091 1.0 1.0 896 896 - A 1792 8064 0.14 1 E->W 235.4 - 1059 1.0 1.0 896 896 - A 1792 8064 0.13 Line E Level 2 LnE, Lev2 2 W->E 25.8 25.8 554 - 1.0 - 532 1.00 532 11438 0.05 2 E->W 25.2 25.2 542 - 1.0 - 532 1.00 532 11438 0.05 Line F LnF, Lev2 - W->E - - 1024 - - - - - - 4288 - - E->W - - 1021 - - - - - - 4288 - Wall F-1 4 W->E 163.9 - 1024 - 1.0 - 686 - 686 4288 0.24 4 E->W 163.4 - 1021 - 1.0 - 686 - 686 4288 0.24 Level 1 LnF, Lev1 - W->E - - 3062 - - - - - - 11200 - - E->W - - 3034 - - - - - - 11200 - Wall F-1 1 W->E 489.8 - 3062 1.0 1.0 896 896 - A 1792 11200 0.27 1 E->W 485.4 - 3034 1.0 1.0 896 896 - A 1792 11200 0.27 Line I Level 2 LnI, Lev2 2 Both 87.9 87.9 967 - 1.0 - 532 1.00 532 5283 0.17 Level 1 LnI, Lev1 2 Both 147.7 147.7 2105 - 1.0 - 532 1.00 532 7581 0.28 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. *WARNING - Design capacity has been exceeded. WARNING - For shearline(s) A, B, C, D, E, F, G, H, I, 1, 2, 3, 4, 5, 7, 8, 11, 12, 13, a shearwall that passed the design check on the initial run failed the final check when forces were redistributed to wall segments using shearwall deflection. Try to adjust wall materials to achieve a passing design, or choose a different force distribution option in the Design Settings. 19 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (flexible wind design) Level 1 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 3464 3464 HDU5-SDS2. 5645 0.61 V Elem 0.00 22.88 Min 2103 2103 Refer to upper level 1-1 R End 0.00 26.88 Min 1360 1360 HDU5-SDS2. 5645 0.24 Line 2 2-1 L End 4.50 27.13 1 365 365 HDU5-SDS2. 5645 0.06 2-1 R End 4.50 41.88 1 363 363 HDU5-SDS2. 5645 0.06 Line 3 3-1 L End 7.75 17.13 Min 4073 4073 HDU5-SDS2. 5645 0.72 V Elem 8.50 26.38 Min 1846 1846 Refer to upper level 3-1 R End 7.75 27.13 Min 2226 2226 HDU5-SDS2. 5645 0.39 Line 4 4-1 L End 16.50 17.13 Min 45186 45186 HDU5-SDS2. 5645 8.00* 4-1 R End 16.50 19.88 Min 45186 45186 HDU5-SDS2. 5645 8.00* Line 5 5-1 L End 19.50 42.13 1 4005 4005 HDU5-SDS2. 5645 0.71 5-1 R End 19.50 45.88 1 3973 3973 HDU5-SDS2. 5645 0.70 Line 8 8-1 L End 35.75 26.88 1 1391 1391 HDU5-SDS2. 5645 0.25 8-1 R End 35.75 45.88 1 1380 1380 HDU5-SDS2. 5645 0.24 Line 12 12-1 L End 57.50 22.13 Min 6130 6130 HDU5-SDS2. 5645 1.09* V Elem 57.50 26.13 Min 7546 7546 Refer to upper level 12-1 R End 57.50 34.88 Min 13676 13676 HDU5-SDS2. 5645 2.42* Line 13 13-1 L End 63.75 35.12 Min 1450 1450 HDU5-SDS2. 5645 0.26 13-1 R End 63.75 51.88 Min 1450 1450 HDU5-SDS2. 5645 0.26 Line A A-1 L End 0.12 17.00 1 769 769 HDU5-SDS2. 5645 0.14 V Elem 9.38 17.00 1 418 418 Refer to upper level A-1 R End 16.38 17.00 1 349 349 HDU5-SDS2. 5645 0.06 Line B B-1 L End 16.62 20.00 1 245 245 HDU5-SDS2. 5645 0.04 B-1 R End 29.63 20.00 1 242 242 HDU5-SDS2. 5645 0.04 Line C C-1 L End 29.88 22.25 1 559 559 HDU5-SDS2. 5645 0.10 V Elem 49.63 22.25 1 254 254 Refer to upper level C-1 R End 53.63 22.00 1 332 332 HDU5-SDS2. 5645 0.06 C-1 R End 53.63 22.25 1 389 389 HDU5-SDS2. 5645 0.07 C-2 R End 57.38 22.00 1 -632 Line D D-1 L End 0.12 27.00 1 2311 2311 HDU5-SDS2. 5645 0.41 D-1 R End 4.38 27.00 1 2243 2243 HDU5-SDS2. 5645 0.40 Line E V Elem 36.13 32.00 1 235 235 Refer to upper level V Elem 57.38 32.00 1 230 230 Refer to upper level Line F F-1 L End 57.63 35.00 1 6129 6129 HDU5-SDS2. 5645 1.09* F-1 R End 63.63 35.00 1 6083 6083 HDU5-SDS2. 5645 1.08* Line I I-1 L End 49.63 52.00 1 1353 1353 HDU5-SDS2. 5645 0.24 V Elem 49.88 52.00 1 897 897 Refer to upper level I-1 R End 63.63 52.00 1 2250 2250 HDU5-SDS2. 5645 0.40 Level 2 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 2103 2103 HDU5-SDS2. 5645 0.37 1-1 R End 0.00 22.88 Min 2103 2103 HDU5-SDS2. 5645 0.37 Line 3 3-1 L End 8.50 17.13 Min 1846 1846 HDU5-SDS2. 5645 0.33 3-1 R End 8.50 26.38 Min 1846 1846 HDU5-SDS2. 5645 0.33 Line 4 4-1 L End 16.50 17.13 Min 21670 21670 HDU5-SDS2. 5645 3.84* 4-1 R End 16.50 19.88 Min 21670 21670 HDU5-SDS2. 5645 3.84* Line 12 12-1 L End 57.50 26.13 Min 7546 7546 HDU5-SDS2. 5645 1.34* 12-1 R End 57.50 34.88 Min 7546 7546 HDU5-SDS2. 5645 1.34* Line 13 20 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (flexible wind design, continued) 13-1 L End 63.75 35.12 Min 743 743 HDU5-SDS2.5645 0.13 13-1 R End 63.75 51.88 Min 743 743 HDU5-SDS2. 5645 0.13 Line A A-1 L End 0.12 17.00 1 419 419 HDU5-SDS2. 5645 0.07 A-1 R End 9.38 17.00 1 418 418 HDU5-SDS2. 5645 0.07 Line C C-1 L End 29.88 22.25 1 260 260 HDU5-SDS2. 5645 0.05 C-1 R End 49.63 22.25 1 254 254 HDU5-SDS2. 5645 0.04 Line E E-1 L End 36.13 32.00 1 235 235 HDU5-SDS2. 5645 0.04 E-1 R End 57.38 32.00 1 230 230 HDU5-SDS2. 5645 0.04 Line F F-1 L End 57.63 35.00 1 1537 1537 HDU5-SDS2. 5645 0.27 F-1 R End 63.63 35.00 1 1532 1532 HDU5-SDS2. 5645 0.27 Line I I-1 L End 49.88 52.00 1 897 897 HDU5-SDS2. 5645 0.16 I-1 R End 63.63 52.00 1 897 897 HDU5-SDS2. 5645 0.16 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.3-8 ASCE 7 Low-rise: Windward corner(s) and Case A or B from Fig. 28.3-1 ASCE 7 Minimum loads (27.1.5 / 28.3.4) Hold-down Forces: Shear – Wind shear overturning component, based on shearline force, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Dead – Dead load resisting component, factored for ASD by 0.60 Uplift - Uplift wind load component, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Cmb'd - Sum of ASD-factored overturning, dead and uplift forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. - Critical Response = Combined ASD force / Allowable ASD tension load Notes: Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. *WARNING - Design capacity has been exceeded. 21 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (flexible wind design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 2 2-1 Left Wall End 4.50 27.00 1 -240 238 Line 3 3-1 Right Wall End 7.75 27.25 1 1460 -1460 Line 4 4-1 Right Wall End 16.50 20.00 1 6323 -6323 Line 5 5-1 Left Wall End 19.50 42.00 1 -1255 1245 Line 8 8-1 Left Wall End 35.75 26.75 1 -620 615 8-1 Right Wall End 35.75 46.00 1 551 -546 Line 12 12-1 Right Wall End 57.50 35.00 1 4921 -4921 Line B B-1 Left Wall End 16.50 20.00 1 -109 108 B-1 Right Wall End 29.75 20.00 1 157 -155 Line C C-1 Left Wall End 29.75 22.25 1 -545 531 Line D D-1 Right Wall End 4.50 27.00 1 1006 -976 Line F F-1 Left Wall End 57.50 35.00 1 -2739 2714 Line I I-1 Right Opening 3 49.50 52.00 1 -1043 1043 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 1 1-1 Left Opening 1 0.00 23.00 1 503 -503 Line 3 3-1 Right Wall End 8.50 26.50 1 1177 -1177 Line 4 4-1 Right Wall End 16.50 20.00 1 5827 -5827 Line 12 12-1 Right Opening 1 57.50 26.00 1 -978 978 12-1 Right Wall End 57.50 35.00 1 4158 -4158 Line A A-1 Left Opening 1 9.50 17.00 1 183 -182 Line C C-1 Left Wall End 29.75 22.25 1 -295 288 C-1 Left Opening 1 49.75 22.25 1 77 -75 C-1 Right Opening 1 52.75 22.25 1 47 -46 Line E E-1 Left Wall End 36.00 32.00 1 -329 322 Line F F-1 Left Wall End 57.50 35.00 1 -916 914 Line I I-1 Right Opening 3 49.75 52.00 1 -488 488 I-1 Left Opening 4 58.00 52.00 1 33 -33 I-1 Right Opening 4 61.00 52.00 1 -70 70 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise corner; Case A or B Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force (vmax from 4.3.6.4.1.1 for perforated walls) Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 22 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Rigid Diaphragm Wind Design ASCE 7 Directional (All Heights) Loads SHEAR RESULTS N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 458.8 458.8 2753 - 1.0 - 532 1.00 532 3192 0.86 Level 1 Ln1, Lev1 1 S->N 224.8 - 2248 1.0 1.0 896 896 - A 1792 17920 0.13 1 N->S 253.0 - 2530 1.0 1.0 896 896 - A 1792 17920 0.14 Line 2 Ln2, Lev1 2 S->N 277.6 277.6 4163 - 1.0 - 532 1.00 532 7980 0.52 2 N->S 255.1 255.1 3827 - 1.0 - 532 1.00 532 7980 0.48 Line 3 Level 2 Ln3, Lev2 2 S->N 581.1 581.1 5521 - 1.0 - 532 1.00 532 5054 1.09* 2 N->S 581.2 581.2 5521 - 1.0 - 532 1.00 532 5054 1.09* Level 1 Ln3, Lev1 2 S->N 180.2 180.2 1847 - 1.0 - 532 1.00 532 5453 0.34 2 N->S 201.8 201.8 2068 - 1.0 - 532 1.00 532 5453 0.38 Line 4 Level 2 Ln4, Lev2 - Both - - 754 - - - - - - 2683 - Wall 4-1 5 Both 251.5 - 754 - .88 - 1022 - 894 2683 0.28 Level 1 Ln4, Lev1 - S->N - - 240 - - - - - - 4704 - - N->S - - 227 - - - - - - 4704 - Wall 4-1 1 S->N 80.1 - 240 .88 .88 896 896 - A 1568 4704 0.05 1 N->S 75.7 - 227 .88 .88 896 896 - A 1568 4704 0.05 Line 5 Ln5, Lev1 2 S->N 75.8 75.8 303 - 1.0 - 532 1.00 532 1892 0.14 2 N->S 72.2 72.2 289 - 1.0 - 532 1.00 532 1892 0.14 Line 8 Ln8, Lev1 - S->N - - 6659 - - - - - - 13433 - - N->S - - 6593 - - - - - - 13433 - Wall 8-1 2 S->N 345.9 345.9 6659 - 1.0 - 532 1.00 532 10241 0.65 2 N->S 342.5 342.5 6593 - 1.0 - 532 1.00 532 10241 0.64 Wall 8-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 3192 0.00 Line 12 Level 2 Ln12, Lev2 2 Both 302.6 302.6 2723 - 1.0 - 532 1.00 532 4788 0.57 Level 1 Ln12, Lev1 - S->N - - 4565 - - - - - - 23296 - - N->S - - 4221 - - - - - - 23296 - Wall 12-1 1 S->N 351.2 - 4565 1.0 1.0 896 896 - A 1792 23296 0.20 1 N->S 324.7 - 4221 1.0 1.0 896 896 - A 1792 23296 0.18 Line 13 Level 2 Ln13, Lev2 2 S->N 375.3 375.3 6379 - 1.0 - 532 1.00 532 9044 0.71 2 N->S 375.2 375.2 6378 - 1.0 - 532 1.00 532 9044 0.71 Level 1 Ln13, Lev1 2 S->N 248.5 248.5 4225 - 1.0 - 532 1.00 532 9044 0.47 2 N->S 264.4 264.4 4495 - 1.0 - 532 1.00 532 9044 0.50 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 2 W->E 28.3 28.3 269 - 1.0 - 532 1.00 532 5054 0.05 2 E->W 28.0 28.0 266 - 1.0 - 532 1.00 532 5054 0.05 Level 1 LnA, Lev1 1 W->E 110.2 - 1818 1.0 1.0 896 896 - A 1792 29568 0.06 1 E->W 19.2 - 317 1.0 1.0 896 896 - A 1792 29568 0.01 Line B LnB, Lev1 - W->E - - 1267 - - - - - - 23744 - - E->W - - 249 - - - - - - 23744 - Wall B-1 1 W->E 95.6 - 1267 1.0 1.0 896 896 - A 1792 23744 0.05 1 E->W 18.8 - 249 1.0 1.0 896 896 - A 1792 23744 0.01 Line C Level 2 23 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (rigid wind design, continued) LnC, Lev2 - W->E - - 1286 - - - - - - 12532 - - E->W - - 1275 - - - - - - 12532 - Wall C-1 2 W->E 64.3 64.3 1286 - 1.0 - 532 1.00 532 10640 0.12 2 E->W 63.8 63.8 1275 - 1.0 - 532 1.00 532 10640 0.12 Wall C-2 2 Both 0.0 0 - 1.0 - 532 1.00 532 1892 0.00 Level 1 LnC, Lev1 - W->E - - 2902 - - - - - - 49952 - - E->W - - 6767 - - - - - - 49952 - Wall C-1 1 W->E 103.2 - 2478 1.0 1.0 896 896 - A 1792 43008 0.06 1 E->W 282.0 - 6767 1.0 1.0 896 896 - A 1792 43008 0.16 Wall C-2 1 W->E 106.1 - 424 .97 .97 896 896 - A 1736 6944 0.06 1 E->W 0.0 - 0 .97 .97 896 896 - A 1736 6944 0.00 Line D LnD, Lev1 - W->E - - 170 - - - - - - 8064 - - E->W - - 43 - - - - - - 8064 - Wall D-1 1 W->E 37.8 - 170 1.0 1.0 896 896 - A 1792 8064 0.02 1 E->W 9.5 - 43 1.0 1.0 896 896 - A 1792 8064 0.01 Line E Level 2 LnE, Lev2 2 W->E 67.8 67.8 1458 - 1.0 - 532 1.00 532 11438 0.13 2 E->W 67.3 67.3 1447 - 1.0 - 532 1.00 532 11438 0.13 Line F LnF, Lev2 - W->E - - 149 - - - - - - 4288 - - E->W - - 148 - - - - - - 4288 - Wall F-1 4 W->E 23.9 - 149 - 1.0 - 686 - 686 4288 0.03 4 E->W 23.7 - 148 - 1.0 - 686 - 686 4288 0.03 Level 1 LnF, Lev1 - W->E - - 359 - - - - - - 11200 - - E->W - - 110 - - - - - - 11200 - Wall F-1 1 W->E 57.4 - 359 1.0 1.0 896 896 - A 1792 11200 0.03 1 E->W 17.6 - 110 1.0 1.0 896 896 - A 1792 11200 0.01 Line I Level 2 LnI, Lev2 2 W->E 34.9 34.9 384 - 1.0 - 532 1.00 532 5283 0.07 2 E->W 34.7 34.7 382 - 1.0 - 532 1.00 532 5283 0.07 Level 1 LnI, Lev1 2 W->E 125.0 125.0 1781 - 1.0 - 532 1.00 532 7581 0.23 2 E->W 50.4 50.4 718 - 1.0 - 532 1.00 532 7581 0.09 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir - Direction of wind force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "S" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. *WARNING - Design capacity has been exceeded. WARNING - For shearline(s) A, B, C, D, E, F, G, H, I, 1, 2, 3, 4, 5, 7, 8, 11, 12, 13, a shearwall that passed the design check on the initial run failed the final check when forces were redistributed to shearlines and/or wall segments using shearwall deflection. Try to adjust wall materials to achieve a passing design, or choose a different force distribution option in the Design Settings. 24 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (rigid wind design) Level 1 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 6677 6677 HDU5-SDS2. 5645 1.18* V Elem 0.00 22.88 Min 4603 4603 Refer to upper level 1-1 R End 0.00 26.88 Min 2335 2335 HDU5-SDS2. 5645 0.41 Line 2 2-1 L End 4.50 27.13 Min 2540 2540 HDU5-SDS2. 5645 0.45 2-1 R End 4.50 41.88 Min 2335 2335 HDU5-SDS2. 5645 0.41 Line 3 3-1 L End 7.75 17.13 Min 7034 7034 HDU5-SDS2. 5645 1.25* V Elem 8.50 26.38 Min 5372 5372 Refer to upper level 3-1 R End 7.75 27.13 Min 1861 1861 HDU5-SDS2. 5645 0.33 Line 4 4-1 L End 16.50 17.13 Min 3255 3255 HDU5-SDS2. 5645 0.58 4-1 R End 16.50 19.88 Min 3212 3212 HDU5-SDS2. 5645 0.57 Line 5 5-1 L End 19.50 42.13 Min 819 819 HDU5-SDS2. 5645 0.15 5-1 R End 19.50 45.88 Min 779 779 HDU5-SDS2. 5645 0.14 Line 8 8-1 L End 35.75 26.88 Min 3154 3154 HDU5-SDS2. 5645 0.56 8-1 R End 35.75 45.88 Min 3123 3123 HDU5-SDS2. 5645 0.55 Line 12 12-1 L End 57.50 22.13 Min 3223 3223 HDU5-SDS2. 5645 0.57 V Elem 57.50 26.13 Min 2801 2801 Refer to upper level 12-1 R End 57.50 34.88 Min 5780 5780 HDU5-SDS2. 5645 1.02* Line 13 13-1 L End 63.75 35.12 Min 6937 6937 HDU5-SDS2. 5645 1.23* 13-1 R End 63.75 51.88 Min 7082 7082 HDU5-SDS2. 5645 1.25* Line A A-1 L End 0.12 17.00 1 1269 1269 HDU5-SDS2. 5645 0.22 V Elem 9.38 17.00 1 259 259 Refer to upper level A-1 R End 16.38 17.00 1 175 175 HDU5-SDS2. 5645 0.03 Line B B-1 L End 16.62 20.00 1 877 877 HDU5-SDS2. 5645 0.16 B-1 R End 29.63 20.00 1 172 172 HDU5-SDS2. 5645 0.03 Line C C-1 L End 29.88 22.25 1 1525 1525 HDU5-SDS2. 5645 0.27 V Elem 49.63 22.25 1 581 581 Refer to upper level C-1 R End 53.63 22.25 1 2564 2564 HDU5-SDS2. 5645 0.45 C-1 R End 53.63 22.00 1 80 80 HDU5-SDS2. 5645 0.01 Line D D-1 L End 0.12 27.00 1 360 360 HDU5-SDS2. 5645 0.06 D-1 R End 4.38 27.00 1 90 90 HDU5-SDS2. 5645 0.02 Line E V Elem 36.13 32.00 1 618 618 Refer to upper level V Elem 57.38 32.00 1 613 613 Refer to upper level Line F F-1 L End 57.63 35.00 1 763 763 HDU5-SDS2. 5645 0.14 F-1 R End 63.63 35.00 1 387 387 HDU5-SDS2. 5645 0.07 Line I I-1 L End 49.63 52.00 1 1145 1145 HDU5-SDS2. 5645 0.20 V Elem 49.88 52.00 1 356 356 Refer to upper level I-1 R End 63.63 52.00 1 816 816 HDU5-SDS2. 5645 0.14 Level 2 Tensile ASD Line-Location [ft] Load Holddown Force [lbs]Cap Crit Wall Posit'n X Y Case Shear Dead Uplift Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 Min 4602 4602 HDU5-SDS2. 5645 0.82 1-1 R End 0.00 22.88 Min 4603 4603 HDU5-SDS2. 5645 0.82 Line 3 3-1 L End 8.50 17.13 Min 5371 5371 HDU5-SDS2. 5645 0.95 3-1 R End 8.50 26.38 Min 5372 5372 HDU5-SDS2. 5645 0.95 Line 4 4-1 L End 16.50 17.13 Min 2469 2469 HDU5-SDS2. 5645 0.44 4-1 R End 16.50 19.88 Min 2469 2469 HDU5-SDS2. 5645 0.44 Line 12 12-1 L End 57.50 26.13 Min 2801 2801 HDU5-SDS2. 5645 0.50 12-1 R End 57.50 34.88 Min 2801 2801 HDU5-SDS2. 5645 0.50 Line 13 13-1 L End 63.75 35.12 Min 4667 4667 HDU5-SDS2.5645 0.83 25 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (rigid wind design, continued) 13-1 R End 63.75 51.88 Min 4666 4666 HDU5-SDS2.5645 0.83 Line A A-1 L End 0.12 17.00 1 262 262 HDU5-SDS2. 5645 0.05 A-1 R End 9.38 17.00 1 259 259 HDU5-SDS2. 5645 0.05 Line C C-1 L End 29.88 22.25 1 586 586 HDU5-SDS2. 5645 0.10 C-1 R End 49.63 22.25 1 581 581 HDU5-SDS2. 5645 0.10 Line E E-1 L End 36.13 32.00 1 618 618 HDU5-SDS2. 5645 0.11 E-1 R End 57.38 32.00 1 613 613 HDU5-SDS2. 5645 0.11 Line F F-1 L End 57.63 35.00 1 224 224 HDU5-SDS2. 5645 0.04 F-1 R End 63.63 35.00 1 222 222 HDU5-SDS2. 5645 0.04 Line I I-1 L End 49.88 52.00 1 356 356 HDU5-SDS2. 5645 0.06 I-1 R End 63.63 52.00 1 354 354 HDU5-SDS2. 5645 0.06 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All Heights: Case 1 or 2 from Fig. 27.3-8 ASCE 7 Low-rise: Windward corner(s) and Case A or B from Fig. 28.3-1 ASCE 7 Minimum loads (27.1.5 / 28.3.4) Hold-down Forces: Shear – Wind shear overturning component, based on shearline force, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Dead – Dead load resisting component, factored for ASD by 0.60 Uplift - Uplift wind load component, factored for ASD by 0.60. For perforated walls, T from SDPWS 4.3-8 is used. Cmb'd - Sum of ASD-factored overturning, dead and uplift forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. - Critical Response = Combined ASD force / Allowable ASD tension load Notes: Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. *WARNING - Design capacity has been exceeded. 26 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (rigid wind design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 2 2-1 Left Wall End 4.50 27.00 1 -1665 1531 Line 3 3-1 Right Wall End 7.75 27.25 1 1090 -1220 Line 4 4-1 Right Wall End 16.50 20.00 1 211 -200 Line 5 5-1 Left Wall End 19.50 42.00 1 -257 244 Line 8 8-1 Left Wall End 35.75 26.75 1 -1405 1391 8-1 Right Wall End 35.75 46.00 1 1249 -1236 Line 12 12-1 Right Wall End 57.50 35.00 1 2587 -2392 Line B B-1 Left Wall End 16.50 20.00 1 -391 77 B-1 Right Wall End 29.75 20.00 1 563 -110 Line C C-1 Left Wall End 29.75 22.25 1 -1502 3501 Line D D-1 Right Wall End 4.50 27.00 1 157 -39 Line F F-1 Left Wall End 57.50 35.00 1 -321 98 Line I I-1 Right Opening 3 49.50 52.00 1 -882 356 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Load Force [lbs]Force [lbs] Wall or Opening X Y Case ---> <------> <--- Line 1 1-1 Left Opening 1 0.00 23.00 1 1101 -1101 Line 3 3-1 Right Wall End 8.50 26.50 1 3423 -3423 Line 4 4-1 Right Wall End 16.50 20.00 1 664 -664 Line 12 12-1 Right Opening 1 57.50 26.00 1 -363 363 12-1 Right Wall End 57.50 35.00 1 1543 -1543 Line A A-1 Left Opening 1 9.50 17.00 1 114 -113 Line C C-1 Left Wall End 29.75 22.25 1 -665 660 C-1 Left Opening 1 49.75 22.25 1 173 -172 C-1 Right Opening 1 52.75 22.25 1 106 -105 Line E E-1 Left Wall End 36.00 32.00 1 -867 860 Line F F-1 Left Wall End 57.50 35.00 1 -134 133 Line I I-1 Right Opening 3 49.75 52.00 1 -194 193 I-1 Left Opening 4 58.00 52.00 1 13 -13 I-1 Right Opening 4 61.00 52.00 1 -28 27 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Load Case - Results are for critical load case: ASCE 7 All heights Case 1 or 2 ASCE 7 Low-rise corner; Case A or B Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force (vmax from 4.3.6.4.1.1 for perforated walls) Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 27 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force [lbs] [lbs][sq.ft]E-W N-S E-W: Fpx Design N-S: Fpx Design 2 60861 1629.3 12238 12238 9089 9089 9089 9089 1 38624 1629.3 4088 4088 5768 8658 5768 5768 All 99484 - 16326 16326 - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Story Shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm Force – Minimum ASD-factored force for diaphragm design, used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx is from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 2.5 as per 12.2-1. Redundancy Factor p (rho): E-W 1.30, N-S 1.30 Input by user (overriding calculated value). Applies to shearwall design, hold-down forces and the drag strut force component based on shearline forces; does not apply to story drift, out-of- plane force, or the diaphragm force Fpx and the drag strut force component based on it. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.07; Ev = 0.213 D unfactored; 0.149 D factored; total dead load factor: 0.6 - 0.149 = 0.451 tension, 1.0 + 0.149 = 1.149 compression. 28 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (flexible seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 158.0 158.0 948 - 1.0 - 380 1.00 380 2280 0.42 Level 1 Ln1, Lev1 1 Both 109.5 - 1095 1.0 1.0 640 640 - A 1280 12800 0.09 Line 2 Ln2, Lev1 2 Both 17.2 17.2 258 - 1.0 - 380 1.00 380 5700 0.05 Line 3 Level 2 Ln3, Lev2 2 Both 116.7 116.7 1109 - 1.0 - 380 1.00 380 3610 0.31 Level 1 Ln3, Lev1 2 Both 137.2 137.2 1406 - 1.0 - 380 1.00 380 3895 0.36 Line 4 Level 2 Ln4, Lev2 - Both - - 3821 - - - - - - 1916 - Wall 4-1 5 Both 1273.5 - 3821 - .88 - 730 - 639 1916 1.99* Level 1 Ln4, Lev1 - Both - - 4088 - - - - - - 3360 - Wall 4-1 1 Both 1362.5 - 4088 .88 .88 640 640 - A 1120 3360 1.22* Line 5 Ln5, Lev1 2 Both 119.8 119.8 479 - 1.0 - 380 1.00 380 1351 0.32 Line 8 Ln8, Lev1 - Both - - 1165 - - - - - - 9595 - Wall 8-1 2 Both 60.5 60.5 1165 - 1.0 - 380 1.00 380 7315 0.16 Wall 8-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 2280 0.00 Line 12 Level 2 Ln12, Lev2 2 Both 493.1 493.1 4438 - 1.0 - 380 1.00 380 3420 1.30* Level 1 Ln12, Lev1 - Both - - 5291 - - - - - - 16640 - * Wall 12-1 1 Both 407.0 - 5291 1.0 1.0 640 640 - A 1280 16640 0.32 Line 13 Level 2 Ln13, Lev2 2 Both 48.3 48.3 821 - 1.0 - 380 1.00 380 6460 0.13 Level 1 Ln13, Lev1 2 Both 63.2 63.2 1074 - 1.0 - 380 1.00 380 6460 0.17 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 2 Both 296.8 296.8 2819 - 1.0 - 380 1.00 380 3610 0.78 Level 1 LnA, Lev1 1 Both 183.0 - 3020 1.0 1.0 640 640 - A 1280 21120 0.14 Line B LnB, Lev1 - Both - - 469 - - - - - - 16960 - Wall B-1 1 Both 35.4 - 469 1.0 1.0 640 640 - A 1280 16960 0.03 Line C Level 2 LnC, Lev2 - Both - - 1978 - - - - - - 8951 - Wall C-1 2 Both 98.9 98.9 1978 - 1.0 - 380 1.00 380 7600 0.26 Wall C-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 1351 0.00 Level 1 LnC, Lev1 - Both - - 2413 - - - - - - 35680 - Wall C-1 1 W->E 46.9 - 1126 1.0 1.0 640 640 - A 1280 30720 0.04 1 E->W 100.5 - 2413 1.0 1.0 640 640 - A 1280 30720 0.08 Wall C-2 1 W->E 321.8 - 1287 .97 .97 640 640 - A 1240 4960 0.26 1 E->W 0.0 - 0 .97 .97 640 640 - A 1240 4960 0.00 Line D LnD, Lev1 - Both - - 1148 - - - - - - 5760 - Wall D-1 1 Both 255.0 - 1148 1.0 1.0 640 640 - A 1280 5760 0.20 Line E Level 2 LnE, Lev2 2 Both 69.9 69.9 1503 - 1.0 - 380 1.00 380 8170 0.18 Line F LnF, Lev2 - Both - - 2345 - - - - - - 3063 - Wall F-1 4^Both 375.2 - 2345 - 1.0 - 490 - 490 3063 0.77 Level 1 LnF, Lev1 - Both - - 4438 - - - - - - 8000 - 29 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (flexible seismic design, continued) Wall F-1 1 Both 710.1 - 4438 1.0 1.0 640 640 - A 1280 8000 0.55 Line I Level 2 LnI, Lev2 2 Both 228.1 228.1 2509 - 1.0 - 380 1.00 380 3774 0.60 Level 1 LnI, Lev1 2 Both 237.6 237.6 3386 - 1.0 - 380 1.00 380 5415 0.63 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. The contribution to shear resistance from gypsum, fiberboard, or lumber sheathing is taken as zero because of the "Ignore non-wood-panel contribution…" Design Setting. Refer to the Sheathing Materials table for the wall groups affected. *WARNING - Design capacity has been exceeded. 30 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (flexible seismic design) Level 1 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 2596 2596 HDU5-SDS2. 5645 0.46 V Elem 0.00 22.88 1585 1585 Refer to upper level 1-1 R End 0.00 26.88 1011 1011 HDU5-SDS2. 5645 0.18 Line 2 2-1 L End 4.50 27.13 157 157 HDU5-SDS2. 5645 0.03 2-1 R End 4.50 41.88 157 157 HDU5-SDS2. 5645 0.03 Line 3 3-1 L End 7.75 17.13 2344 2344 HDU5-SDS2. 5645 0.42 V Elem 8.50 26.38 1079 1079 Refer to upper level 3-1 R End 7.75 27.13 1266 1266 HDU5-SDS2. 5645 0.22 Line 4 4-1 L End 16.50 17.13 25881 25881 HDU5-SDS2. 5645 4.58* 4-1 R End 16.50 19.88 25881 25881 HDU5-SDS2. 5645 4.58* Line 5 5-1 L End 19.50 42.13 1293 1293 HDU5-SDS2. 5645 0.23 5-1 R End 19.50 45.88 1293 1293 HDU5-SDS2. 5645 0.23 Line 8 8-1 L End 35.75 26.88 552 552 HDU5-SDS2. 5645 0.10 8-1 R End 35.75 45.88 552 552 HDU5-SDS2. 5645 0.10 Line 12 12-1 L End 57.50 22.13 3735 3735 HDU5-SDS2. 5645 0.66 V Elem 57.50 26.13 4565 4565 Refer to upper level 12-1 R End 57.50 34.88 8300 8300 HDU5-SDS2. 5645 1.47* Line 13 13-1 L End 63.75 35.12 1178 1178 HDU5-SDS2. 5645 0.21 13-1 R End 63.75 51.88 1178 1178 HDU5-SDS2. 5645 0.21 Line A A-1 L End 0.12 17.00 4416 4416 HDU5-SDS2. 5645 0.78 V Elem 9.38 17.00 2743 2743 Refer to upper level A-1 R End 16.38 17.00 1673 1673 HDU5-SDS2. 5645 0.30 Line B B-1 L End 16.62 20.00 325 325 HDU5-SDS2. 5645 0.06 B-1 R End 29.63 20.00 325 325 HDU5-SDS2. 5645 0.06 Line C C-1 L End 29.88 22.25 1328 1328 HDU5-SDS2. 5645 0.24 V Elem 49.63 22.25 902 902 Refer to upper level C-1 R End 53.63 22.00 2663 2663 HDU5-SDS2. 5645 0.47 C-1 R End 53.63 22.25 914 914 HDU5-SDS2. 5645 0.16 C-2 R End 57.38 22.00 -3090 Line D D-1 L End 0.12 27.00 2430 2430 HDU5-SDS2. 5645 0.43 D-1 R End 4.38 27.00 2430 2430 HDU5-SDS2. 5645 0.43 Line E V Elem 36.13 32.00 636 636 Refer to upper level V Elem 57.38 32.00 636 636 Refer to upper level Line F F-1 L End 57.63 35.00 10175 10175 HDU5-SDS2. 5645 1.80* F-1 R End 63.63 35.00 10175 10175 HDU5-SDS2. 5645 1.80* Line I I-1 L End 49.63 52.00 2177 2177 HDU5-SDS2. 5645 0.39 V Elem 49.88 52.00 2326 2326 Refer to upper level I-1 R End 63.63 52.00 4503 4503 HDU5-SDS2. 5645 0.80 Level 2 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 1585 1585 HDU5-SDS2. 5645 0.28 1-1 R End 0.00 22.88 1585 1585 HDU5-SDS2. 5645 0.28 Line 3 3-1 L End 8.50 17.13 1079 1079 HDU5-SDS2. 5645 0.19 3-1 R End 8.50 26.38 1079 1079 HDU5-SDS2. 5645 0.19 Line 4 4-1 L End 16.50 17.13 12503 12503 HDU5-SDS2. 5645 2.21* 4-1 R End 16.50 19.88 12503 12503 HDU5-SDS2. 5645 2.21* Line 12 12-1 L End 57.50 26.13 4565 4565 HDU5-SDS2. 5645 0.81 12-1 R End 57.50 34.88 4565 4565 HDU5-SDS2. 5645 0.81 Line 13 31 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (flexible seismic design, continued) 13-1 L End 63.75 35.12 601 601 HDU5-SDS2.5645 0.11 13-1 R End 63.75 51.88 601 601 HDU5-SDS2. 5645 0.11 Line A A-1 L End 0.12 17.00 2743 2743 HDU5-SDS2. 5645 0.49 A-1 R End 9.38 17.00 2743 2743 HDU5-SDS2. 5645 0.49 Line C C-1 L End 29.88 22.25 902 902 HDU5-SDS2. 5645 0.16 C-1 R End 49.63 22.25 902 902 HDU5-SDS2. 5645 0.16 Line E E-1 L End 36.13 32.00 636 636 HDU5-SDS2. 5645 0.11 E-1 R End 57.38 32.00 636 636 HDU5-SDS2. 5645 0.11 Line F F-1 L End 57.63 35.00 3518 3518 HDU5-SDS2. 5645 0.62 F-1 R End 63.63 35.00 3518 3518 HDU5-SDS2. 5645 0.62 Line I I-1 L End 49.88 52.00 2326 2326 HDU5-SDS2. 5645 0.41 I-1 R End 63.63 52.00 2326 2326 HDU5-SDS2. 5645 0.41 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Hold-down Forces: Shear – Seismic shear overturning component, factored for ASD by 0.7. For perforated walls, T from SDPWS 4.3-8 is used Dead – Dead load resisting component, factored for ASD by 0.60 Ev – Vertical seismic load effect from ASCE 7 12.4.2.2 = -0.2Sds x ASD seismic factor x unfactored D = 0.249 x factored D. Refer to Seismic Information table for more details. Cmb'd - Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. – Critical Response = Combined ASD force/Allowable ASD tension load Notes: Combined force from ASCE 7 2.4.1 load combination 10 = - (0.6D - 0.7Ev + 0.7Eh); Eh (from 12.4.2.1) = - shear overturning force Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. *WARNING - Design capacity has been exceeded. 32 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (flexible seismic design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 2 Shearline force 385 385 2-1 Left Wall End 4.50 27.00 -154 154 Line 3 Shearline force 1830 1830 3-1 Right Wall End 7.75 27.25 1080 -1080 Line 4 Shearline force 5174 5174 4-1 Right Wall End 16.50 20.00 4553 -4553 Line 5 Shearline force 714 714 5-1 Left Wall End 19.50 42.00 -604 604 Line 8 Shearline force 1737 1737 8-1 Left Wall End 35.75 26.75 -366 366 8-1 Right Wall End 35.75 46.00 326 -326 Line 12 Shearline force 6819 6819 12-1 Right Wall End 57.50 35.00 3864 -3864 Line B Shearline force 512 512 B-1 Left Wall End 16.50 20.00 -158 158 B-1 Right Wall End 29.75 20.00 227 -227 Line C Shearline force 2453 2453 C-1 Left Wall End 29.75 22.25 -1269 1269 Line D Shearline force 1721 1721 D-1 Right Wall End 4.50 27.00 1586 -1586 Line F Shearline force 5410 5410 F-1 Left Wall End 57.50 35.00 -4839 4839 Line I Shearline force 3466 3466 I-1 Right Opening 3 49.50 52.00 -1717 1717 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 1 Shearline force 948 948 1-1 Left Opening 1 0.00 23.00 379 -379 Line 3 Shearline force 1109 1109 3-1 Right Wall End 8.50 26.50 687 -687 Line 4 Shearline force 3821 3821 4-1 Right Wall End 16.50 20.00 3362 -3362 Line 12 Shearline force 4438 4438 12-1 Right Opening 1 57.50 26.00 -592 592 12-1 Right Wall End 57.50 35.00 2515 -2515 Line A Shearline force 2819 2819 A-1 Left Opening 1 9.50 17.00 1196 -1196 Line C Shearline force 1978 1978 C-1 Left Wall End 29.75 22.25 -1024 1024 C-1 Left Opening 1 49.75 22.25 267 -267 C-1 Right Opening 1 52.75 22.25 163 -163 Line E Shearline force 1503 1503 E-1 Left Wall End 36.00 32.00 -893 893 Line F Shearline force 2345 2345 F-1 Left Wall End 57.50 35.00 -2098 2098 Line I Shearline force 2509 2509 I-1 Right Opening 3 49.75 52.00 -1265 1265 33 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (flexible seismic design, continued) I-1 Left Opening 4 58.00 52.00 86 -86 I-1 Right Opening 4 61.00 52.00 -180 180 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force shown. For SDC C-F, it is the greater of the design shearline force and the diaphragm force Fpx, added to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength (omega) as per 12.10.1.1. Refer to Seismic Information table for diaphragm forces and omega factor. For SDC D-F, if horizontal torsional irregularities 2, 3, or 4 are input, or vertical irregularity 4 detected or input, 25% increase from 12.3.3.4 applied. For perforated walls, this force is converted to vmax using 4.3.6.4.1.1. Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 34 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 Rigid Diaphragm Seismic Design SEISMIC INFORMATION Level Mass Area Story Shear [lbs]Diaphragm Force [lbs] [lbs][sq.ft]E-W N-S E-W: Fpx Design N-S: Fpx Design 2 60861 1629.3 12238 12238 9089 9089 9089 9089 1 38624 1629.3 4088 4088 5768 15860 5768 5768 All 99484 - 16326 16326 - - - - Legend: Mass – Sum of all generated and input building masses on level = wx in ASCE 7 equation 12.8-12. Story Shear – Total unfactored (strength-level) shear force induced at level x, = Fx in ASCE 7 equation 12.8-11. Diaphragm Force – Minimum ASD-factored force for diaphragm design, used by Shearwalls only for drag strut forces, as per Exception to 12.10.2.1. Fpx is from Eqns. 12.10-1, -2, and -3. Design = The greater of the story shear and Fpx + transfer forces from discontinuous shearlines, factored by overstrength (omega) as per 12.10.1.1. Omega = 3.0 as per 12.2-1. On at least one level and force direction, a torsional irregularity was detected and torsional amplification factor Ax applied according to 12.8.4.3. Refer to the Torsional Analysis section of the Log File output for the values of Ax. Redundancy Factor p (rho): E-W 1.30, N-S 1.30 Input by user (overriding calculated value). Applies to shearwall design, hold-down forces and the drag strut force component based on shearline forces; does not apply to story drift, out-of- plane force, or the diaphragm force Fpx and the drag strut force component based on it. Vertical Earthquake Load Ev Ev = 0.2 Sds D; Sds = 1.07; Ev = 0.213 D unfactored; 0.149 D factored; total dead load factor: 0.6 - 0.149 = 0.451 tension, 1.0 + 0.149 = 1.149 compression. 35 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (rigid seismic design) N-S W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line 1 Level 2 Ln1, Lev2 2 Both 304.1 304.1 1825 - 1.0 - 380 1.00 380 2280 0.80 Level 1 Ln1, Lev1 1 S->N 151.6 - 1516 1.0 1.0 640 640 - A 1280 12800 0.12 1 N->S 170.9 - 1709 1.0 1.0 640 640 - A 1280 12800 0.13 Line 2 Ln2, Lev1 2 S->N 192.7 192.7 2891 - 1.0 - 380 1.00 380 5700 0.51 2 N->S 179.2 179.2 2688 - 1.0 - 380 1.00 380 5700 0.47 Line 3 Level 2 Ln3, Lev2 2 Both 386.3 386.3 3670 - 1.0 - 380 1.00 380 3610 1.02* Level 1 Ln3, Lev1 2 S->N 120.1 120.1 1231 - 1.0 - 380 1.00 380 3895 0.32 2 N->S 135.5 135.5 1389 - 1.0 - 380 1.00 380 3895 0.36 Line 4 Level 2 Ln4, Lev2 - Both - - 451 - - - - - - 1916 - Wall 4-1 5 Both 150.4 - 451 - .88 - 730 - 639 1916 0.24 Level 1 Ln4, Lev1 - S->N - - 142 - - - - - - 3360 - - N->S - - 135 - - - - - - 3360 - Wall 4-1 1 S->N 47.4 - 142 .88 .88 640 640 - A 1120 3360 0.04 1 N->S 45.0 - 135 .88 .88 640 640 - A 1120 3360 0.04 Line 5 Ln5, Lev1 2 S->N 44.4 44.4 178 - 1.0 - 380 1.00 380 1351 0.12 2 N->S 42.3 42.3 169 - 1.0 - 380 1.00 380 1351 0.11 Line 8 Ln8, Lev1 - S->N - - 4137 - - - - - - 9595 - - N->S - - 4129 - - - - - - 9595 - Wall 8-1 2 S->N 214.9 214.9 4137 - 1.0 - 380 1.00 380 7315 0.57 2 N->S 214.5 214.5 4129 - 1.0 - 380 1.00 380 7315 0.56 Wall 8-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 2280 0.00 Line 12 Level 2 Ln12, Lev2 2 Both 200.6 200.6 1806 - 1.0 - 380 1.00 380 3420 0.53 Level 1 Ln12, Lev1 - S->N - - 3087 - - - - - - 16640 - - N->S - - 2846 - - - - - - 16640 - Wall 12-1 1 S->N 237.5 - 3087 1.0 1.0 640 640 - A 1280 16640 0.19 1 N->S 218.9 - 2846 1.0 1.0 640 640 - A 1280 16640 0.17 Line 13 Level 2 Ln13, Lev2 2 Both 274.4 274.4 4664 - 1.0 - 380 1.00 380 6460 0.72 Level 1 Ln13, Lev1 2 S->N 188.1 188.1 3197 - 1.0 - 380 1.00 380 6460 0.49 2 N->S 196.9 196.9 3347 - 1.0 - 380 1.00 380 6460 0.52 E-W W For ASD Shear Force [plf]Asp-Cub Allowable Shear [plf]Resp. Shearlines Gp Dir v vmax/vft V [lbs]Int Ext Int Ext Co C Cmb V [lbs]Ratio Line A Level 2 LnA, Lev2 2 Both 120.7 120.7 1147 - 1.0 - 380 1.00 380 3610 0.32 Level 1 LnA, Lev1 1 W->E 141.4 - 2333 1.0 1.0 640 640 - A 1280 21120 0.11 1 E->W 66.8 - 1102 1.0 1.0 640 640 - A 1280 21120 0.05 Line B LnB, Lev1 - W->E - - 1713 - - - - - - 16960 - - E->W - - 793 - - - - - - 16960 - Wall B-1 1 W->E 129.3 - 1713 1.0 1.0 640 640 - A 1280 16960 0.10 1 E->W 59.8 - 793 1.0 1.0 640 640 - A 1280 16960 0.05 Line C Level 2 LnC, Lev2 - Both - - 4190 - - - - - - 8951 - Wall C-1 2 Both 209.5 209.5 4190 - 1.0 - 380 1.00 380 7600 0.55 Wall C-2 2 Both 0.0 0 - 1.0 - 380 1.00 380 1351 0.00 Level 1 LnC, Lev1 - W->E - - 8124 - - - - - - 35680 - - E->W - - 11362 - - - - - - 35680 - Wall C-1 1 W->E 212.7 - 5105 1.0 1.0 640 640 - A 1280 30720 0.17 36 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 SHEAR RESULTS (rigid seismic design, continued) 1 E->W 473.4 - 11362 1.0 1.0 640 640 - A 1280 30720 0.37 Wall C-2 1 W->E 754.8 - 3019 .97 .97 640 640 - A 1240 4960 0.61 1 E->W 0.0 - 0 .97 .97 640 640 - A 1240 4960 0.00 Line D LnD, Lev1 - W->E - - 234 - - - - - - 5760 - - E->W - - 126 - - - - - - 5760 - Wall D-1 1 W->E 52.1 - 234 1.0 1.0 640 640 - A 1280 5760 0.04 1 E->W 28.0 - 126 1.0 1.0 640 640 - A 1280 5760 0.02 Line E Level 2 LnE, Lev2 2 Both 203.4 203.4 4373 - 1.0 - 380 1.00 380 8170 0.54 Line F LnF, Lev2 - Both - - 552 - - - - - - 3063 - Wall F-1 4 Both 88.4 - 552 - 1.0 - 490 - 490 3063 0.18 Level 1 LnF, Lev1 - W->E - - 505 - - - - - - 8000 - - E->W - - 310 - - - - - - 8000 - Wall F-1 1 W->E 80.7 - 505 1.0 1.0 640 640 - A 1280 8000 0.06 1 E->W 49.5 - 310 1.0 1.0 640 640 - A 1280 8000 0.04 Line I Level 2 LnI, Lev2 2 Both 132.4 132.4 1315 - 1.0 - 380 1.00 380 3774 0.35 Level 1 LnI, Lev1 2 W->E 176.4 176.4 2514 - 1.0 - 380 1.00 380 5415 0.46 2 E->W 121.2 121.2 1727 - 1.0 - 380 1.00 380 5415 0.32 Legend: W Gp - Wall design group defined in Sheathing and Framing Materials tables, where it shows associated Standard Wall. "^" means that this wall is critical for all walls in the Standard Wall group. For Dir – Direction of seismic force along shearline. v - Design shear force on segment = ASD-factored shear force per unit length of full-height sheathing (FHS) vmax/vft - Perforated walls: Collector and in-plane anchorage force as per SDPWS eqn. 4.3-9 = V/FHS/Co. FHS is factored for narrow segments as per 4.3.4.3 Force-transfer walls: Shear force in piers above and below either openings or piers beside opening(s). Aspect ratio factor does not apply to these piers. V - ASD factored shear force. For shearline: total shearline force. For wall: total of all segments on wall. For segment: force on segment Asp/Cub – For wall: Unblocked structural wood panel factor Cub from SDPWS 4.3.3.2. For segment or force-transfer pier: Aspect Ratio Factor from SDPWS 4.3.4.2. Int - Unit shear capacity of interior sheathing; Ext - Unit shear capacity of exterior sheathing. For wall: Unfactored. For segment: Include Cub factor and aspect ratio adjustments. Co - Adjustment factor for perforated walls from SDPWS Equation 4.3-5. C - Sheathing combination rule, A = Add capacities, S = Strongest side or twice weakest, G = Stiffness-based using SDPWS 4.3-3. Cmb - Combined interior and exterior unit shear capacity including perforated wall factor Co. V – Total factored shear capacity of shearline, wall or segment. Crit Resp – Response ratio = v/Cmb = design shear force/unit shear capacity. "W" indicates that the wind design criterion was critical in selecting wall. Notes: Refer to Elevation View diagrams for individual level for uplift anchorage force t for perforated walls given by SDPWS 4.3.6.4.2,4. The contribution to shear resistance from gypsum, fiberboard, or lumber sheathing is taken as zero because of the "Ignore non-wood-panel contribution…" Design Setting. Refer to the Sheathing Materials table for the wall groups affected. *WARNING - Design capacity has been exceeded. 37 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (rigid seismic design) Level 1 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 4450 4450 HDU5-SDS2. 5645 0.79 V Elem 0.00 22.88 3051 3051 Refer to upper level 1-1 R End 0.00 26.88 1578 1578 HDU5-SDS2. 5645 0.28 Line 2 2-1 L End 4.50 27.13 1764 1764 HDU5-SDS2. 5645 0.31 2-1 R End 4.50 41.88 1640 1640 HDU5-SDS2. 5645 0.29 Line 3 3-1 L End 7.75 17.13 4678 4678 HDU5-SDS2. 5645 0.83 V Elem 8.50 26.38 3571 3571 Refer to upper level 3-1 R End 7.75 27.13 1250 1250 HDU5-SDS2. 5645 0.22 Line 4 4-1 L End 16.50 17.13 1942 1942 HDU5-SDS2. 5645 0.34 4-1 R End 16.50 19.88 1918 1918 HDU5-SDS2. 5645 0.34 Line 5 5-1 L End 19.50 42.13 480 480 HDU5-SDS2. 5645 0.09 5-1 R End 19.50 45.88 457 457 HDU5-SDS2. 5645 0.08 Line 8 8-1 L End 35.75 26.88 1960 1960 HDU5-SDS2. 5645 0.35 8-1 R End 35.75 45.88 1956 1956 HDU5-SDS2. 5645 0.35 Line 12 12-1 L End 57.50 22.13 2179 2179 HDU5-SDS2. 5645 0.39 V Elem 57.50 26.13 1857 1857 Refer to upper level 12-1 R End 57.50 34.88 3866 3866 HDU5-SDS2. 5645 0.68 Line 13 13-1 L End 63.75 35.12 5130 5130 HDU5-SDS2. 5645 0.91 13-1 R End 63.75 51.88 5211 5211 HDU5-SDS2. 5645 0.92 Line A A-1 L End 0.12 17.00 2408 2408 HDU5-SDS2. 5645 0.43 V Elem 9.38 17.00 1116 1116 Refer to upper level A-1 R End 16.38 17.00 610 610 HDU5-SDS2. 5645 0.11 Line B B-1 L End 16.62 20.00 1186 1186 HDU5-SDS2. 5645 0.21 B-1 R End 29.63 20.00 549 549 HDU5-SDS2. 5645 0.10 Line C C-1 L End 29.88 22.25 3844 3844 HDU5-SDS2. 5645 0.68 V Elem 49.63 22.25 1909 1909 Refer to upper level C-1 R End 53.63 22.25 4305 4305 HDU5-SDS2. 5645 0.76 C-1 R End 53.63 22.00 5311 5311 HDU5-SDS2. 5645 0.94 C-2 R End 57.38 22.00 -7246 Line D D-1 L End 0.12 27.00 496 496 HDU5-SDS2. 5645 0.09 D-1 R End 4.38 27.00 267 267 HDU5-SDS2. 5645 0.05 Line E V Elem 36.13 32.00 1852 1852 Refer to upper level V Elem 57.38 32.00 1852 1852 Refer to upper level Line F F-1 L End 57.63 35.00 1585 1585 HDU5-SDS2. 5645 0.28 F-1 R End 63.63 35.00 1293 1293 HDU5-SDS2. 5645 0.23 Line I I-1 L End 49.63 52.00 1616 1616 HDU5-SDS2. 5645 0.29 V Elem 49.88 52.00 1219 1219 Refer to upper level I-1 R End 63.63 52.00 2329 2329 HDU5-SDS2. 5645 0.41 Level 2 Tensile ASD Line-Location [ft]Holddown Force [lbs]Cap Crit Wall Posit'n X Y Shear Dead Ev Cmb'd Hold-down [lbs]Resp. Line 1 1-1 L End 0.00 17.13 3051 3051 HDU5-SDS2. 5645 0.54 1-1 R End 0.00 22.88 3051 3051 HDU5-SDS2. 5645 0.54 Line 3 3-1 L End 8.50 17.13 3571 3571 HDU5-SDS2. 5645 0.63 3-1 R End 8.50 26.38 3571 3571 HDU5-SDS2. 5645 0.63 Line 4 4-1 L End 16.50 17.13 1477 1477 HDU5-SDS2. 5645 0.26 4-1 R End 16.50 19.88 1477 1477 HDU5-SDS2. 5645 0.26 Line 12 12-1 L End 57.50 26.13 1857 1857 HDU5-SDS2. 5645 0.33 12-1 R End 57.50 34.88 1857 1857 HDU5-SDS2. 5645 0.33 Line 13 38 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 HOLD-DOWN DESIGN (rigid seismic design, continued) 13-1 L End 63.75 35.12 3412 3412 HDU5-SDS2.5645 0.60 13-1 R End 63.75 51.88 3412 3412 HDU5-SDS2. 5645 0.60 Line A A-1 L End 0.12 17.00 1116 1116 HDU5-SDS2. 5645 0.20 A-1 R End 9.38 17.00 1116 1116 HDU5-SDS2. 5645 0.20 Line C C-1 L End 29.88 22.25 1909 1909 HDU5-SDS2. 5645 0.34 C-1 R End 49.63 22.25 1909 1909 HDU5-SDS2. 5645 0.34 Line E E-1 L End 36.13 32.00 1852 1852 HDU5-SDS2. 5645 0.33 E-1 R End 57.38 32.00 1852 1852 HDU5-SDS2. 5645 0.33 Line F F-1 L End 57.63 35.00 828 828 HDU5-SDS2. 5645 0.15 F-1 R End 63.63 35.00 828 828 HDU5-SDS2. 5645 0.15 Line I I-1 L End 49.88 52.00 1219 1219 HDU5-SDS2. 5645 0.22 I-1 R End 63.63 52.00 1219 1219 HDU5-SDS2. 5645 0.22 Legend: Line-Wall: At wall or opening – Shearline and wall number At vertical element - Shearline Posit'n - Position of stud that hold-down is attached to: V Elem - Vertical element: column or strengthened studs required where not at wall end or opening L or R End - At left or right wall end L or R Op n - At left or right side of opening n t @ Op n - Uplift force t at opening n from offset opening in perforated wall above, from SDPWS 4.3.6.2.1 Location - Co-ordinates in Plan View Hold-down Forces: Shear – Seismic shear overturning component, factored for ASD by 0.7. For perforated walls, T from SDPWS 4.3-8 is used Dead – Dead load resisting component, factored for ASD by 0.60 Ev – Vertical seismic load effect from ASCE 7 12.4.2.2 = -0.2Sds x ASD seismic factor x unfactored D = 0.249 x factored D. Refer to Seismic Information table for more details. Cmb'd - Sum of ASD-factored overturning, dead and vertical seismic forces. May also include the uplift force t from perforated walls from SDPWS 4.3.6.2.1 when openings are staggered. Hold-down – Device used from hold-down database Cap – Allowable ASD tension load Crit. Resp. – Critical Response = Combined ASD force/Allowable ASD tension load Notes: Combined force from ASCE 7 2.4.1 load combination 10 = - (0.6D - 0.7Ev + 0.7Eh); Eh (from 12.4.2.1) = - shear overturning force Refer to Shear Results table for factor Co, and shearline dimensions table for the sum of Li, used to calculate tension force T for perforated walls from SDPWS Eqn. 4.3-8. Designer is responsible for design of connection from wall to floor or foundation for shear force shown in Shear Results table. Refer to SDPWS 4.3.6.4.3 for foundation anchor bolt requirements. 39 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (rigid seismic design) Level 1 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 2 Shearline force 3178 3178 2-1 Left Wall End 4.50 27.00 -1271 1179 Line 3 Shearline force 1359 1359 3-1 Right Wall End 7.75 27.25 802 -903 Line 4 Shearline force 159 159 4-1 Right Wall End 16.50 20.00 140 -133 Line 5 Shearline force 200 200 5-1 Left Wall End 19.50 42.00 -169 161 Line 8 Shearline force 4775 4775 8-1 Left Wall End 35.75 26.75 -1007 1003 8-1 Right Wall End 35.75 46.00 895 -892 Line 12 Shearline force 3600 3600 12-1 Right Wall End 57.50 35.00 2040 -1876 Line B Shearline force 2177 2177 B-1 Left Wall End 16.50 20.00 -671 310 B-1 Right Wall End 29.75 20.00 966 -446 Line C Shearline force 10358 10358 C-1 Left Wall End 29.75 22.25 -5359 7499 Line D Shearline force 299 299 D-1 Right Wall End 4.50 27.00 276 -147 Line F Shearline force 637 637 F-1 Left Wall End 57.50 35.00 -570 346 Line I Shearline force 3130 3130 I-1 Right Opening 3 49.50 52.00 -1551 1053 Level 2 Drag Strut Strap/Blocking Line- Position on Wall Location [ft]Force [lbs]Force [lbs] Wall or Opening X Y ---> <------> <--- Line 1 Shearline force 1825 1825 1-1 Left Opening 1 0.00 23.00 730 -730 Line 3 Shearline force 3670 3670 3-1 Right Wall End 8.50 26.50 2275 -2275 Line 4 Shearline force 451 451 4-1 Right Wall End 16.50 20.00 397 -397 Line 12 Shearline force 1806 1806 12-1 Right Opening 1 57.50 26.00 -241 241 12-1 Right Wall End 57.50 35.00 1023 -1023 Line A Shearline force 1147 1147 A-1 Left Opening 1 9.50 17.00 487 -487 Line C Shearline force 4190 4190 C-1 Left Wall End 29.75 22.25 -2168 2168 C-1 Left Opening 1 49.75 22.25 565 -565 C-1 Right Opening 1 52.75 22.25 346 -346 Line E Shearline force 4373 4373 E-1 Left Wall End 36.00 32.00 -2599 2599 Line F Shearline force 552 552 F-1 Left Wall End 57.50 35.00 -494 494 Line I Shearline force 1315 1315 I-1 Right Opening 3 49.75 52.00 -663 663 40 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 COLLECTOR FORCES (rigid seismic design, continued) I-1 Left Opening 4 58.00 52.00 45 -45 I-1 Right Opening 4 61.00 52.00 -94 94 Legend: Line-Wall - Shearline and wall number Position…- Side of opening or wall end that drag strut is attached to Location - Co-ordinates in Plan View Drag strut Force - Axial force in transfer element at openings, gaps, or changes in design shear along shearline. + : tension; - : compression. Based on ASD-factored shearline force shown. For SDC C-F, it is the greater of the design shearline force and the diaphragm force Fpx, added to shearline force from story above and to forces transferred from discontinuous shearlines factored by overstrength (omega) as per 12.10.1.1. Refer to Seismic Information table for diaphragm forces and omega factor. For SDC D-F, if horizontal torsional irregularities 1a or 1b are detected, or if other horizontal irregularities are input, or if vertical irregularity 4 detected or input, 25% increase from 12.3.3.4 applied. For perforated walls, this force is converted to vmax using 4.3.6.4.1.1. Strap/Blocking Force – For force-transfer walls, force transferred from above and below opening to shearwall pier. -> Due to shearline force in the west-to-east or south-to-north direction <- Due to shearline force in the east-to-west or north-to-south direction 41 WoodWorks® Shearwalls 2 - GARAGE REMOVED.wsw Jan. 10, 2021 00:08:24 42 BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 6.00 Le = 6.67 Ft0.9963Cl Stability R2= 4.8 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 1405 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 36%37%73%98% Ratio Status 1170 # Reaction 2 TL4.68Beam Wt per ft Conditions Data 0.03 in(1.5) DL Defl= 320 400Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.08 0.03 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 3.25 0 0 I = 550 H = 150 EndStartPar Unif TL 500 = AUniform TL: R1= 4.8 in² 405 L / 655L / 240 15 1958 # 1591 1170 # 1958 #1958 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1101 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.06 0.16 19.25 14.05 17.65 17.34 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 6 HF #2 Date: 1/08/21 MF-1-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1958R1 = 1958 I H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 11.73 Le = 12.44 Ft0.9806Cl Stability R2= 5.8 in² (psi) '# # # ft Lu = 6.25 Ft l Selection 2876 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 48%48%64%71% Ratio Status 2260 # Reaction 2 TL6.83Beam Wt per ft Conditions Data 0.12 inRecom Camber=0.08 in(1.5) DL Defl= 320 403Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.16 0.07 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 6.25 6.25 0 0 I = 550 H = 150 EndStartPar Unif TL 504 = AUniform TL: R1= 5.8 in² 650 L / 496L / 240 43 3784 # 5912 2260 # 3784 #3784 # 6.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 240 2400 2353 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.15 0.31 28.13 17.97 42.19 30.15 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 3-1/8x 9 GLB 24F-V4 DF/DF Date: 1/08/21 MF-1-6VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 3784R1 = 3784 I H Uniform Load A SPAN = 6.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 5.57 Le = 10.43 Ft0.9984Cl Stability R2= 2.8 in² (psi) '# # # ft Lu = 5.25 Ft l Selection 860 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 23%15%28%75% Ratio Status 945 # Reaction 2 TL10.02Beam Wt per ft Conditions Data <0.01 in.(1.5) DL Defl= 360Uniform LL: OKOKOKOK LL Defl 0.13 0.03 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 420 = AUniform TL: R1= 2.8 in² 405 L / >1000L / 240 53 1129 # 1482 945 # 1129 #1129 # 5.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 0.950.80 N/A 1.00 0.80 1.00 1.00 1.000 Ci Incised Cr Repetitive Cd Duration CF Size Factor Adjustments 1.1 1.0 140 112 575 459 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.04 0.26 41.25 11.52 51.56 38.71 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018, Incised PT 6x 8 HF #2 Date: 1/08/21 MF-1-D-5VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1129R1 = 1129 Uniform Load A SPAN = 5.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 4.0 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 1280 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 33%22%33%82% Ratio Status 1350 # Reaction 2 TL12.7Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 360Uniform LL: OKOKOKOK LL Defl 0.19 0.06 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 420 = AUniform TL: R1= 4.0 in² 405 L / >1000L / 240 95 1623 # 3042 1350 # 1623 #1623 # 7.5 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 0.950.80 N/A 1.00 0.80 1.00 1.00 1.000 Ci Incised Cr Repetitive Cd Duration CF Size Factor Adjustments 1.1 1.0 140 112 675 540 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.08 0.38 52.25 17.14 82.73 67.61 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018, Incised PT 6x 10 HF #2 Date: 1/08/21 MF-1-D-8AVAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1623R1 = 1623 Uniform Load A SPAN = 7.5 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 2.9 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 939 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 27%18%24%63% Ratio Status 960 # Reaction 2 TL12.7Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 240Uniform LL: OKOKOKOK LL Defl 0.20 0.05 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 280 = AUniform TL: R1= 2.9 in² 405 L / >1000L / 240 102 1171 # 2342 960 # 1171 #1171 # 8.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 0.950.80 N/A 1.00 0.80 1.00 1.00 1.000 Ci Incised Cr Repetitive Cd Duration CF Size Factor Adjustments 1.1 1.0 140 112 675 540 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.07 0.40 52.25 12.58 82.73 52.03 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018, Incised PT 6x 10 HF #2 Date: 1/08/21 MF-1-D-8BVAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1171R1 = 1171 Uniform Load A SPAN = 8 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 6.00 Le = 6.67 Ft0.9963Cl Stability R2= 4.2 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 1230 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 37%31%64%86% Ratio Status 1186 # Reaction 2 TL4.68Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 270 180 280Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.08 0.03 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 3.25 3.25 0 0 0 J = 340 I = 210 H = 150 EndStartPar Unif TL 350 = AUniform TL: R1= 4.2 in² 405 L / 776L / 240 15 1714 # 1393 1186 # 1714 #1714 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1101 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.05 0.16 19.25 12.30 17.65 15.18 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 6 HF #2 Date: 1/08/21 MF-2-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1714R1 = 1714 J I H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 11.73 Le = 12.44 Ft0.9806Cl Stability R2= 7.2 in² (psi) '# # # ft Lu = 6.25 Ft l Selection 3555 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 57%61%79%88% Ratio Status 2688 # Reaction 2 TL6.83Beam Wt per ft Conditions Data 0.15 inRecom Camber=0.10 in(1.5) DL Defl= 400 180 280Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.16 0.09 L / 837L / 480 LL Actual DeflLL Max Defl Attributes 6.25 6.25 6.25 0 0 0 J = 780 I = 210 H = 150 EndStartPar Unif TL 350 = AUniform TL: R1= 7.2 in² 650 L / 394L / 240 43 4678 # 7309 2688 # 4678 #4678 # 6.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 240 2400 2353 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.19 0.31 28.13 22.22 42.19 37.27 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 3-1/8x 9 GLB 24F-V4 DF/DF Date: 1/08/21 MF-2-6VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 4678R1 = 4678 J I H Uniform Load A SPAN = 6.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 8.59 Le = 6.70 Ft0.9943Cl Stability R2= 4.9 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 4164 #Max V (Reduced) 625 1.00 Ch Shear Stress Loads 9%9%88%81% Ratio Status 1899 # Reaction 2 TL9.57Beam Wt per ft Conditions Data <0.01 in.(1.5) DL Defl= 315 450 2700 300Uniform LL: Par Unif LLPoint LL OKOKOKOK LL Defl 0.08 <0.01 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 1.0 1.0 0 0 0 J = 368 I = 850 H = 1501.0B = 5400 DistancePoint TL EndStartPar Unif TL 375 = AUniform TL: R1= 9.3 in² 625 L / >1000L / 240 31 5807 # 4922 3249 # 3037 #5807 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.100 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.6 1.6 180 180 900 984 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.01 0.16 39.38 34.70 73.83 60.01 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 12 DF-L #2 Date: 1/08/21 MF-3-3AVAROL Uniform and partial uniform loads are lbs per lineal ft. Pt loads: R2 = 3037R1 = 5807 J I H Uniform Load A SPAN = 3.25 FT B BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 8.60 Le = 6.70 Ft0.9910Cl Stability R2= 4.7 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 4490 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 17%18%100%59% Ratio Status 1899 # Reaction 2 TL6.83Beam Wt per ft Conditions Data 0.02 inRecom Camber=0.02 in(1.5) DL Defl= 315 450 2700 300Uniform LL: Par Unif LLPoint LL OKOKOKOK LL Defl 0.08 0.01 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 1.0 1.0 0 0 0 J = 368 I = 850 H = 1501.0B = 5400 DistancePoint TL EndStartPar Unif TL 375 = AUniform TL: R1= 8.9 in² 650 L / >1000L / 240 22 5802 # 4919 3249 # 3033 #5802 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 240 2400 2378 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.03 0.16 28.13 28.06 42.19 24.82 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 3-1/8x 9 GLB 24F-V4 DF/DF Date: 1/08/21 MF-3-3AVAROL Uniform and partial uniform loads are lbs per lineal ft. Pt loads: R2 = 3033R1 = 5802 J I H Uniform Load A SPAN = 3.25 FT B BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 7.00 Le = 6.67 Ft0.9948Cl Stability R2= 4.1 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 909 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 38%26%55%76% Ratio Status 1207 # Reaction 2 TL4.01Beam Wt per ft Conditions Data 0.01 in(1.5) DL Defl= 315 450 300Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.08 0.03 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 3.25 3.25 0 2.75 2.75 J = 368 I = 850 H = 150 EndStartPar Unif TL 375 = AUniform TL: R1= 3.1 in² 405 L / 915L / 240 13 1675 # 1049 1017 # 1675 #1252 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1099 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.04 0.16 16.50 9.09 15.13 11.45 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 2x 6 HF #2 Date: 1/08/21 MF-3-3BVAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1675R1 = 1252 J I H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 6.90 Le = 6.70 Ft0.9950Cl Stability R2= 5.9 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 1512 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 20%20%60%70% Ratio Status 1454 # Reaction 2 TL6.17Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 375 520Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 3.25 0 0 I = 675 H = 150 EndStartPar Unif TL 650 = AUniform TL: R1= 5.9 in² 405 L / >1000L / 240 20 2407 # 1956 1454 # 2407 #2407 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1099 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.03 0.16 25.38 15.12 30.66 21.34 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 8 HF #2 Date: 1/08/21 MF-5-3AVAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 2407R1 = 2407 I H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 6.90 Le = 6.70 Ft0.9950Cl Stability R2= 5.7 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 1461 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 19%19%58%67% Ratio Status 1389 # Reaction 2 TL6.17Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 375 480Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.25 3.25 0 0 I = 675 H = 150 EndStartPar Unif TL 600 = AUniform TL: R1= 5.7 in² 405 L / >1000L / 240 20 2326 # 1890 1389 # 2326 #2326 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1099 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.03 0.16 25.38 14.61 30.66 20.62 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 8 HF #2 Date: 1/08/21 MF-5-3BVAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 2326R1 = 2326 I H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 9.2 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 7174 #Max V (Reduced) 950 1.00 Ch Shear Stress Loads 90%89%42%93% Ratio Status 5363 # Reaction 2 TL15.59Beam Wt per ft Conditions Data 0.24 in(1.5) DL Defl= 375 600Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.28 0.25 L / 531L / 480 LL Actual DeflLL Max Defl Attributes 11.0 11.0 0 0 I = 675 H = 150 EndStartPar Unif TL 750 = AUniform TL: R1= 9.2 in² 950 L / 270L / 240 171 8748 # 24058 5363 # 8748 #8748 # 11.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.001 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.8 1.8 410 410 2500 2503 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.49 0.55 62.34 26.25 123.39 115.34 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (3) 1-3/4x 11-7/8 1.9E LP SolidStart LVL Date: 1/08/21 MF-5-11VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 8748R1 = 8748 I H Uniform Load A SPAN = 11 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 11.6 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 6878 #Max V (Reduced) 750 1.00 Ch Shear Stress Loads 74%73%74%89% Ratio Status 5363 # Reaction 2 TL12.25Beam Wt per ft Conditions Data 0.20 in(1.5) DL Defl= 375 600Uniform LL: Par Unif LL OKOKOKOK LL Defl 0.28 0.20 L / 644L / 480 LL Actual DeflLL Max Defl Attributes 11.0 11.0 0 0 I = 675 H = 150 EndStartPar Unif TL 750 = AUniform TL: R1= 11.6 in² 750 L / 329L / 240 135 8730 # 24007 5363 # 8730 #8730 # 11.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 0.978 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 2.0 2.0 285 285 2900 2837 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.40 0.55 49.00 36.20 114.33 101.55 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 1-3/4x 14 2.0E LP SolidStart LVL Date: 1/08/21 MF-5-11VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 8730R1 = 8730 I H Uniform Load A SPAN = 11 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 7.00 Le = 6.67 Ft0.9948Cl Stability R2= 2.7 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 778 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 30%21%47%64% Ratio Status 861 # Reaction 2 TL4.01Beam Wt per ft Conditions Data <0.01 in.(1.5) DL Defl= 530Uniform LL: OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 663 = AUniform TL: R1= 2.7 in² 405 L / >1000L / 240 13 1083 # 880 861 # 1083 #1083 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1099 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.03 0.16 16.50 7.78 15.13 9.61 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 2x 6 HF #2 Date: 1/08/21 MF-6-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1083R1 = 1083 Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 3.0 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 951 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 45%31%49%76% Ratio Status 980 # Reaction 2 TL4.68Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 490Uniform LL: OKOKOKOK LL Defl 0.10 0.04 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 613 = AUniform TL: R1= 3.0 in² 405 L / 773L / 240 19 1234 # 1234 980 # 1234 #1234 # 4.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 150 850 1105 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.06 0.20 19.25 9.51 17.65 13.40 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 6 HF #2 Date: 1/08/21 MF-6-4VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1234R1 = 1234 Uniform Load A SPAN = 4 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 1.4 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 948 #Max V (Reduced) 875 1.00 Ch Shear Stress Loads 73%50%36%65% Ratio Status 980 # Reaction 2 TL2.41Beam Wt per ft Conditions Data 0.03 in(1.5) DL Defl= 490Uniform LL: OKOKOKOK LL Defl 0.10 0.07 L / 661L / 480 LL Actual DeflLL Max Defl Attributes 613 = AUniform TL: R1= 1.4 in² 875 L / 478L / 240 10 1230 # 1230 980 # 1230 #1230 # 4.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.00 1.00 1.00 1.00 1.091 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.6 1.6 410 410 2360 2574 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.10 0.20 9.63 3.47 8.82 5.73 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 1-3/4x 5-1/2 1.5E LP SolidStart LVL Date: 1/08/21 MF-6-4VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1230R1 = 1230 Uniform Load A SPAN = 4 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 13.99 Le = 6.67 Ft0.9649Cl Stability R2= 2.2 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 638 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 26%38%67%93% Ratio Status 492 # Reaction 2 TL2.0Beam Wt per ft Conditions Data 0.03 in(1.5) DL Defl= 303Uniform LL: OKOKOKOK LL Defl 0.11 0.03 L / >1000L / 360 LL Actual DeflLL Max Defl Attributes 545 = AUniform TL: R1= 2.2 in² 405 L / 629L / 240 7 888 # 722 492 # 888 #888 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1226 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.06 0.16 8.25 5.54 7.56 7.06 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 2x 6 HF #2 Date: 1/08/21 UR-1-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 888R1 = 888 Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 9.23 Le = 12.00 Ft0.9886Cl Stability R2= 4.2 in² (psi) '# # # ft Lu = 6.25 Ft l Selection 1388 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 34%51%48%84% Ratio Status 945 # Reaction 2 TL6.17Beam Wt per ft Conditions Data 0.09 in(1.5) DL Defl= 303Uniform LL: OKOKOKOK LL Defl 0.21 0.07 L / >1000L / 360 LL Actual DeflLL Max Defl Attributes 545 = AUniform TL: R1= 4.2 in² 405 L / 469L / 240 39 1721 # 2689 945 # 1721 #1721 # 6.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1256 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.16 0.31 25.38 12.07 30.66 25.68 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 8 HF #2 Date: 1/08/21 UR-1-6VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1721R1 = 1721 Uniform Load A SPAN = 6.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 6.5 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4359 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 55%90%24%52% Ratio Status 2131 # Reaction 2 TL24.28Beam Wt per ft Conditions Data 1.23 inRecom Camber=0.82 in(1.5) DL Defl= 125 175 Par Unif LL OKOKOKOK LL Defl 1.03 0.57 L / 649L / 360 LL Actual DeflLL Max Defl Attributes 31.0 15.5 15.5 0 I = 225 H = 315 EndStartPar Unif TL R1= 7.6 in² 650 L / 267L / 240 753 4910 # 35544 2519 # 4213 #4910 # 31.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 0.916 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2529 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 1.39 1.55 99.94 23.69 324.80 168.67 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 5-1/8x 19-1/2 GLB 24F-V4 DF/DF Date: 1/08/21 UR-1-31VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 4213R1 = 4910 I H SPAN = 31 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 6.6 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4475 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 54%89%20%48% Ratio Status 2131 # Reaction 2 TL29.52Beam Wt per ft Conditions Data 1.23 inRecom Camber=0.82 in(1.5) DL Defl= 125 175 Par Unif LL OKOKOKOK LL Defl 1.03 0.55 L / 672L / 360 LL Actual DeflLL Max Defl Attributes 31.0 15.5 15.5 0 I = 225 H = 315 EndStartPar Unif TL R1= 7.7 in² 650 L / 271L / 240 915 4991 # 36173 2519 # 4294 #4991 # 31.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 0.898 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2480 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 1.37 1.55 121.50 24.32 364.50 175.04 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 6-3/4x 18 GLB 24F-V4 DF/DF Date: 1/08/21 UR-1-31VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 4294R1 = 4991 I H SPAN = 31 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 5.7 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4372 #Max V (Reduced) 750 1.00 Ch Shear Stress Loads 45%74%19%40% Ratio Status 2131 # Reaction 2 TL26.25Beam Wt per ft Conditions Data 0.68 in(1.5) DL Defl= 125 175 Par Unif LL OKOKOKOK LL Defl 1.03 0.47 L / 797L / 360 LL Actual DeflLL Max Defl Attributes 31.0 15.5 15.5 0 I = 225 H = 315 EndStartPar Unif TL R1= 6.6 in² 750 L / 325L / 240 814 4941 # 35780 2519 # 4243 #4941 # 31.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 0.930 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 2.0 2.0 285 328 2900 3100 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 1.14 1.55 105.00 20.01 350.00 138.49 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (3) 1-3/4x 20 2.0E LP SolidStart LVL Date: 1/08/21 UR-1-31VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 4243R1 = 4941 I H SPAN = 31 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 5.8 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4502 #Max V (Reduced) 750 1.00 Ch Shear Stress Loads 46%77%16%37% Ratio Status 2131 # Reaction 2 TL31.5Beam Wt per ft Conditions Data 0.72 in(1.5) DL Defl= 125 175 Par Unif LL OKOKOKOK LL Defl 1.03 0.48 L / 774L / 360 LL Actual DeflLL Max Defl Attributes 31.0 15.5 15.5 0 I = 225 H = 315 EndStartPar Unif TL R1= 6.7 in² 750 L / 310L / 240 977 5022 # 36411 2519 # 4325 #5022 # 31.0 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 0.944 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 2.0 2.0 285 328 2900 3147 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 1.20 1.55 126.00 20.61 378.00 138.83 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (4) 1-3/4x 18 2.0E LP SolidStart LVL Date: 1/08/21 UR-1-31VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 4325R1 = 5022 I H SPAN = 31 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 7.00 Le = 6.67 Ft0.9940Cl Stability R2= 3.1 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 915 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 23%42%48%65% Ratio Status 650 # Reaction 2 TL4.01Beam Wt per ft Conditions Data 0.03 in(1.5) DL Defl= 400Uniform LL: OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.250H = 60 EndStartPar Unif TL 720 = AUniform TL: R1= 3.1 in² 405 L / 857L / 360 13 1274 # 1035 650 # 1274 #1274 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1263 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.05 0.11 16.50 7.95 15.13 9.83 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 2x 6 HF #2 Date: 1/08/21 UR-2-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1274R1 = 1274 H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 10.64 Le = 12.50 Ft0.9853Cl Stability R2= 6.1 in² (psi) '# # # ft Lu = 6.25 Ft l Selection 1855 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 29%54%50%80% Ratio Status 1250 # Reaction 2 TL7.87Beam Wt per ft Conditions Data 0.07 in(1.5) DL Defl= 400Uniform LL: OKOKOKOK LL Defl 0.16 0.05 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 6.250H = 60 EndStartPar Unif TL 720 = AUniform TL: R1= 6.1 in² 405 L / 665L / 360 49 2462 # 3847 1250 # 2462 #2462 # 6.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.200 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1156 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.11 0.21 32.38 16.13 49.91 39.94 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 10 HF #2 Date: 1/08/21 UR-2-6VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 2462R1 = 2462 H Uniform Load A SPAN = 6.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 20.91 Le = 23.72 Ft0.7936Cl Stability R2= 8.1 in² (psi) '# # # ft Lu = 12.25 Ft l Selection 4187 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 46%84%49%75% Ratio Status 2680 # Reaction 2 TL11.39Beam Wt per ft Conditions Data 0.31 inRecom Camber=0.20 in(1.5) DL Defl= 438Uniform LL: OKOKOKOK LL Defl 0.31 0.14 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 12.250H = 60 EndStartPar Unif TL 788 = AUniform TL: R1= 8.1 in² 650 L / 428L / 360 140 5261 # 16111 2680 # 5261 #5261 # 12.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2190 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.34 0.41 46.88 22.76 117.19 88.27 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 3-1/8x 15 GLB 24F-V4 DF/DF Date: 1/08/21 UR-3-12VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 5261R1 = 5261 H Uniform Load A SPAN = 12.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 12.00 Le = 23.34 Ft0.9750Cl Stability R2= 8.1 in² (psi) '# # # ft Lu = 12.25 Ft l Selection 4322 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 38%71%34%46% Ratio Status 2680 # Reaction 2 TL16.81Beam Wt per ft Conditions Data 0.26 inRecom Camber=0.17 in(1.5) DL Defl= 438Uniform LL: OKOKOKOK LL Defl 0.31 0.12 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 12.250H = 60 EndStartPar Unif TL 788 = AUniform TL: R1= 8.1 in² 650 L / 508L / 360 206 5294 # 16213 2680 # 5294 #5294 # 12.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2691 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.29 0.41 69.19 23.49 155.67 72.30 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 5-1/8x 13-1/2 GLB 24F-V4 DF/DF Date: 1/08/21 UR-3-12VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 5294R1 = 5294 H Uniform Load A SPAN = 12.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 5.5 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4263 #Max V (Reduced) 950 1.00 Ch Shear Stress Loads 50%93%28%60% Ratio Status 2680 # Reaction 2 TL12.25Beam Wt per ft Conditions Data 0.22 in(1.5) DL Defl= 438Uniform LL: OKOKOKOK LL Defl 0.31 0.15 L / 957L / 480 LL Actual DeflLL Max Defl Attributes 12.250H = 60 EndStartPar Unif TL 788 = AUniform TL: R1= 5.5 in² 950 L / 389L / 360 150 5266 # 16127 2680 # 5266 #5266 # 12.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 0.978 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.8 1.8 410 472 2500 2812 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.38 0.41 49.00 13.56 114.33 68.81 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 1-3/4x 14 1.9E LP SolidStart LVL Date: 1/08/21 UR-3-12VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 5266R1 = 5266 H Uniform Load A SPAN = 12.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 7.0 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 4432 #Max V (Reduced) 750 1.00 Ch Shear Stress Loads 49%91%33%47% Ratio Status 2680 # Reaction 2 TL15.59Beam Wt per ft Conditions Data 0.22 in(1.5) DL Defl= 438Uniform LL: OKOKOKOK LL Defl 0.31 0.15 L / 973L / 480 LL Actual DeflLL Max Defl Attributes 12.250H = 60 EndStartPar Unif TL 788 = AUniform TL: R1= 7.0 in² 750 L / 394L / 360 191 5286 # 16190 2680 # 5286 #5286 # 12.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.001 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 2.0 2.0 285 328 2900 3339 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.37 0.41 62.34 20.29 123.39 58.19 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (3) 1-3/4x 11-7/8 2.0E LP SolidStart LVL Date: 1/08/21 UR-3-12VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 5286R1 = 5286 H Uniform Load A SPAN = 12.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 13.99 Le = 6.67 Ft0.9649Cl Stability R2= 1.4 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 393 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 15%24%41%58% Ratio Status 284 # Reaction 2 TL2.0Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 175Uniform LL: OKOKOKOK LL Defl 0.11 0.02 L / >1000L / 360 LL Actual DeflLL Max Defl Attributes 3.250H = 20 EndStartPar Unif TL 315 = AUniform TL: R1= 1.4 in² 405 L / >1000L / 240 7 548 # 445 284 # 548 #548 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1226 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.04 0.16 8.25 3.42 7.56 4.35 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 2x 6 HF #2 Date: 1/08/21 UR-6-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 548R1 = 548 H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 7.00 Le = 6.67 Ft0.9940Cl Stability R2= 3.7 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 1078 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 29%49%57%77% Ratio Status 813 # Reaction 2 TL4.01Beam Wt per ft Conditions Data 0.03 in(1.5) DL Defl= 500Uniform LL: OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.250H = 20 EndStartPar Unif TL 900 = AUniform TL: R1= 3.7 in² 405 L / 740L / 360 13 1502 # 1220 813 # 1502 #1502 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1263 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.05 0.11 16.50 9.37 15.13 11.59 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 2x 6 HF #2 Date: 1/08/21 UR-7-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1502R1 = 1502 H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 7.00 Le = 6.67 Ft0.9940Cl Stability R2= 2.8 in² (psi) '# # # ft Lu = 3.25 Ft l Selection 816 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 21%37%43%58% Ratio Status 609 # Reaction 2 TL4.01Beam Wt per ft Conditions Data 0.02 in(1.5) DL Defl= 375Uniform LL: OKOKOKOK LL Defl 0.08 0.02 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 3.250H = 20 EndStartPar Unif TL 675 = AUniform TL: R1= 2.8 in² 405 L / 975L / 360 13 1136 # 923 609 # 1136 #1136 # 3.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1263 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.04 0.11 16.50 7.09 15.13 8.77 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 (2) 2x 6 HF #2 Date: 1/08/21 UR-8-3VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1136R1 = 1136 H Uniform Load A SPAN = 3.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 8.58 Le = 10.37 Ft0.9904Cl Stability R2= 4.3 in² (psi) '# # # ft Lu = 5.25 Ft l Selection 1331 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 33%54%46%71% Ratio Status 952 # Reaction 2 TL6.17Beam Wt per ft Conditions Data 0.05 in(1.5) DL Defl= 363Uniform LL: OKOKOKOK LL Defl 0.13 0.04 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 653 = AUniform TL: R1= 4.3 in² 405 L / 661L / 360 32 1729 # 2269 952 # 1729 #1729 # 5.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.300 Cm Wet Use Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.3 150 173 850 1259 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.10 0.18 25.38 11.57 30.66 21.64 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 4x 8 HF #2 Date: 1/08/21 UR-9-5VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1729R1 = 1729 Uniform Load A SPAN = 5.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 3.8 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 1334 #Max V (Reduced) 405 1.00 Ch Shear Stress Loads 51%88%37%97% Ratio Status 828 # Reaction 2 TL9.57Beam Wt per ft Conditions Data 0.22 in(1.5) DL Defl= 125Uniform LL: OKOKOKOK LL Defl 0.33 0.17 L / 942L / 480 LL Actual DeflLL Max Defl Attributes 225 = AUniform TL: R1= 3.8 in² 405 L / 407L / 360 127 1554 # 5148 828 # 1554 #1554 # 13.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 0.950.80 N/A 1.15 0.80 1.00 1.15 1.100 Ci Incised Cr Repetitive Cd Duration CF Size Factor Adjustments 1.3 1.2 150 138 850 860 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.39 0.44 39.38 14.50 73.83 71.81 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018, Incised PT 4x 12 HF #2 Date: 1/08/21 UR-9-13VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1554R1 = 1554 Uniform Load A SPAN = 13.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 0.00 Le = 0.00 Ft1.0000Cl Stability R2= 2.4 in² (psi) '# # # ft Lu = 0.0 Ft l Selection 1340 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 48%83%22%39% Ratio Status 828 # Reaction 2 TL7.97Beam Wt per ft Conditions Data 0.31 inRecom Camber=0.21 in(1.5) DL Defl= 125Uniform LL: OKOKOKOK LL Defl 0.33 0.16 L / 997L / 480 LL Actual DeflLL Max Defl Attributes 225 = AUniform TL: R1= 2.4 in² 650 L / 434L / 360 106 1543 # 5113 828 # 1543 #1543 # 13.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2760 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.37 0.44 32.81 7.28 57.42 22.23 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 PT 3-1/8x 10-1/2 GLB 24F-V4 DF/DF Date: 1/08/21 UR-9-13VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 1543R1 = 1543 Uniform Load A SPAN = 13.25 FT BeamChek v2019 licensed to: Kenneth H Swartz, Swartz Engineering Reg # 2999-68387 Rb = 15.11 Le = 17.70 Ft0.9479Cl Stability R2= 4.4 in² (psi) '# # # ft Lu = 9.25 Ft l Selection 2299 #Max V (Reduced) 650 1.00 Ch Shear Stress Loads 43%75%38%52% Ratio Status 1503 # Reaction 2 TL7.97Beam Wt per ft Conditions Data 0.20 inRecom Camber=0.13 in(1.5) DL Defl= 325Uniform LL: OKOKOKOK LL Defl 0.23 0.10 L / >1000L / 480 LL Actual DeflLL Max Defl Attributes 9.250H = 20 EndStartPar Unif TL 585 = AUniform TL: R1= 4.4 in² 650 L / 483L / 360 74 2835 # 6556 1503 # 2835 #2835 # 9.25 Min Bearing Area Fc TL Actual DeflTL Max Defl Bm Wt Included Maximum V Max Moment Reaction 2 LL Reaction 1 TL Reaction 1 LL Values 1.001.00 N/A 1.15 1.00 1.00 1.15 1.000 Cm Wet Use Cr Repetitive Cd Duration Cv Volume Adjustments 1.8 1.8 240 276 2400 2616 Reference Values Adjusted Values E (psi x mil)Fv (psi)Fb (psi) 0.23 0.31 32.81 12.49 57.42 30.07 Beam Span TL Defl (in)Shear (in²)Section (in³) Actual Critical NDS 2018 3-1/8x 10-1/2 GLB 24F-V4 DF/DF Date: 1/08/21 UR-10-9VAROL Uniform and partial uniform loads are lbs per lineal ft. R2 = 2835R1 = 2835 H Uniform Load A SPAN = 9.25 FT