HomeMy WebLinkAboutBLD2021-00198 - 08 Site Plan or Approved Site PlanN
5' Setback from
Property Line
15
2
.
0
4
'
Building Footprint = 2,592 SF
Roof Area = 3,105 SF
Deck = 600 SF
Parking/Driveway = 936 SF
Parcel 990600374
0.29 Acrea
Gutter Downspout
EL 325'
Parking
House Deck
Roof Line
16 0 16
OWSI Water
PUD
P
o
w
e
r
1" = 16'
Stormwater Disposal
Raingarden
621 Square Feet
S
e
w
e
r
20' Setback from
Property Line
Access from
Keefe Lane
10'
S
h
e
e
t
Flo
w
f
r
o
m
Par
k
i
n
g
/
D
r
i
v
e
w
a
y
Footing Drain
to Daylight
SI
L
T
F
E
N
C
E
130'
1
3
3
.
2
2
'
59.
1
6
'
4'
EL 330'
EL 320'EL 315'EL 310'EL 305'
Garage
Gutter Downspout
Gutter Downspout
Roof Line
Roof Line
Driveway
250 Gallon
LP Tank
5' Setback from
Property Line
5' Setback from
Property Line
8'-311
16"
15'-10 9
16"
34'-6 9
16"
20'-213
16"
17'-715
16"
27'-27
8"
10'-9 1
16"
11'-911
16"
50'-47
8"
10'-011
16"
LP Lin
e
Corner EL 327'
Corner EL 325'
Corner EL 319'
Corner EL 308'
11'-11 5
16"10'-37
8"
12"
C
u
l
v
e
r
t
i
n
Dit
c
h
u
n
d
e
r
Dri
v
e
w
a
y
16'-53
4"
23'-103
8"
12'-111
8"
23'-83
8"
21'
RAINGARDEN CALCULATION:
3,105SF ROOF AREA FLOWING INTO RAINGARDEN
REGION 1, PORT LUDLOW
DESIRED PERFORMANCE: BEST
DRAINAGE RATE: VERY POOR
REQUIRED SIZING FACTOR: 13%
PONDING DEPTH: 12" (A.H, 6/3/2021)
SIZE FACTOR USED: 20%
RAINGARDEN SIZE USED: 3,105 X 0.2 = 621SF
12" RAINGARDEN SOIL RECOMMENDED
RAINGARDEN DEPTH: AT LEAST 2 FT (A.H, 6/3/2021)
Site Plan
Scale 1
16"=1'
Project Name:
Heddy PL Lot House Plans
Legal Description:
PORT LUDLOW NO 2 AREA 3
LOT 74
Tax Parcel #990600374
0.29 Acre Lot
Jun 02 2021
Jun 03 2021
Jun 03 2021