Loading...
HomeMy WebLinkAboutBLD2020-00659-03- ENERGY WORKSHEETSimple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions". Design Temperature Instructions Design Temperature Difference (∆T)45 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)1,703 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)9.0 15,327 Glazing and Doors U-Factor X Area =UA Instructions 0.30 383 114.90 Skylights U-Factor X Area =UA Instructions 0.50 0 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 1,703 44.28 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions 0.027 0 ________ Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 1,944 108.86 Floors U-Factor X Area UA Instructions 0.025 1,703 42.58 Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions ---0 --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions ---0 ________ Slab on Grade (see Figure 1)F-Factor X Length UA Instructions ---0 ________ Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 310.62 Envelope Heat Load 13,978 Btu / Hour Sum of UA X ∆T Air Leakage Heat Load 7,449 Btu / Hour Volume X 0.6 X ∆T X .018 Building Design Heat Load 21,427 Btu / Hour Air Leakage + Envelope Heat Loss Building and Duct Heat Load 21,427 Btu / Hour Ducts in unconditioned space: Sum of Building Heat Loss X 1.10 Ducts in conditioned space: Sum of Building Heat Loss X 1 Maximum Heat Equipment Output 26,783 Btu / Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2012 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This calculator will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing (window) and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2012 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please call the WSU Energy Extension Program at (360) 956-2042 for assistance. Lot 24 - Cameron Garage Right Olympic Terrace 2 Port Ludlow Associates LLC Cliff Obrien 360-437-8242 Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13) 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies Conditioned Floor Area 1,703 Component Performance, R occupancies Code Target Values Proposed Design Area UA Area UA Doors U =0.300 80 24 80 20 Overhead Glazing U =0.500 0 0 0 0 Vertical Glazing U =0.300 255 77 303 79 Flat/Vaulted Ceilings U =0.026 1,703 44 1,703 34 Wall (above grade) U =0.056 1,992 112 1,944 99 Floors U =0.029 1,703 49 1,703 43 Slab on Grade F =0.540 0 0 0 0 Below Grade Wall U =0.042 0 0 0 0 Below Grade Slab F =0.570 0 0 0 0 Target UA Total 306 Proposed UA Total 275 Target Credits from Table 406.2 3.5 3.5 Qualifies, please check for complete Component Desriptio Exterior Doors Plan Component Door ID Description Ref.U Qt.Feet Inch Feet Inch Area UA 53.00 Custom 0.23 2 3 0 6 8 40 9 55.00 Custom 0.27 1 6 0 6 8 40 11 56.00 Custom 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 80 20 Cameron Garage Right Port ludlow Associates 70 Breaker Lane Port Ludlow, WA 98365 Olympic Terrace 2 Lot 24 Proposed Credits from Table 406.2 If the Proposed UA ≤ the Target UA, and the Proposed Credits from Table 406.2 are ≥ those required in Section R406.2, then the home meets the 2015 WSEC. Sum of Area and UA Width Height Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 1 of 6 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies Overhead Glazing: Plan Component Glazing ID Description Ref.U Qt.Feet Inch Feet Inch Area UA 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 0 0 Height Sum of Area and UA Width Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 2 of 6 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies Vertical Glazing Plan Component Glazing Width ID Description Ref.U Qt.Feet Inch Feet Inch Area UA 212.00 10-6B 0.26 3 2 6 4 6 34 9 212.00 10-6B 0.26 7 2 6 5 6 96 25 212.00 10-6B 0.26 3 5 6 5 6 91 24 212.00 10-6B 0.26 2 7 6 5 6 83 21 217.00 0 0.00 0 0 221.00 0 0.00 0 0 219.00 0 0.00 0 0 216.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 Height Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 3 of 6 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 1.00 0 0.00 0 0 Sum of Area and UA 303 79 Glazing Area Weighted U 0.260 Flat/Vaulted Ceilings Plan Component Attic ID Description Ref.U Area UA 11.00 10-7 0.020 1,703 34 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 1,703 34 Walls (Above Grade) Plan Component Wall ID Description Ref.U Net Area UA 238.00 10-5 0.051 1,944 99 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 1,944 99 Floor (over crawl or exterior) Plan Component Floor ID Description Ref.U Area UA 14.00 10-3 0.025 1,703 43 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 1,703 43Sum of Area and UA Sum of Area and UA Sum of Area and UA Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 4 of 6 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies Slab on Grade (less than 2 feet below grade) Plan Component Slab Slab ID Description Ref.F Length UA 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 0 0 Below Grade Walls and Slabs Plan Component Wall Wall Slab Slab ID Description Ref.U Area Length UA 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 1.00 0 0.000 0 Sum of Area, Length and UA 0 0 0 Sum of Area and UA 0.0 UA 0.0 0.0 0.0 0.0 Wall 0.000 0.000 0.000 0.000 Slab F Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 5 of 6 2015 Washington State Energy Code: UA Alternative Worksheet, Type R-3 Occupancies Opt.Description 1a Efficient Building Envelope 1a 0.5 1b Efficient Building Envelope 1b 1c Efficient Building Envelope 1c 1d Efficient Building Envelope 1d 2a Air Leakage Control and Efficient Ventilation 2a 0.5 2b Air Leakage Control and Efficient Ventilation 2b 2c Air Leakage Control and Efficient Ventilation 2c 3a High Efficiency HVAC 3a 3b High Efficiency HVAC 3b 3c High Efficiency HVAC 3c 3d High Efficiency HVAC 3d 1.0 4 High Efficiency HVAC Distribution System 5a Efficient Water Heating 5a 5b Efficient Water Heating 5b 5c Efficient Water Heating 5c 1.5 5d Efficient Water heating 5d 6 Renewable Electric Energy kWh Total Credits 3.5 *Please refer to Table R406.2 for complete option descriptions 0.5 1.5 0.5 3448 0.5 1.0 1.0 0.5 1.0 1.5 1.0 Credit(s) 0.5 1.0 2.0 0.5 1.0 Table R406.2 Summary 1.0 1.5 Copyright 2013, WSUEEP10-009 (Version 11) Copied by permission from Washington State University Extension Energy Program. (see copyright restrictions) 12/22/2020 6 of 6