Loading...
HomeMy WebLinkAbout074lfvl Eri Engrneerrng. E[l i..rr*l.gv. lnc.. PBC 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com Pervious Disturbed Area: 133 Ac or 55% NaturalArea: 80 Ac or 33% Total Pervious Area: 213 Ac or 88o/o Pervious Area20. Pervious Disturbed Area: 170 Ac or 73o/o NaturalArea: 33 Ac 14o/o Total Pervious Area: 210 Ac or 87o/o Pervious Area Pervious Area 21 Perimeter Buffers: Maritime Village: 25 ft. Minimum building setback Golf Resort:25 ft. Minimum building setback Perimeter Buffers: Same requirements as Alternative 1. Perimeter Buffers: Number Employees: Construction - 1,750 jobs Operation - 225 jobs Clearing and grading: 1 million cubic yards 22. 2t Number Employees: Construction - 1,750 jobs Operation - 225 jobs Clearing and grading 2.2 million cubic yards Number Employees: Clearing and grading Construction Operation - ,#ALf E R N AT,lV.E','il . (10 l:O.i 201 1) ALTERNATTVE 2 (20121 Alternative 3 (2015) HT EA Engineering, Science, and Technology,lnc., PBG 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com 16. Create a replacement wetland in the bottom of the smaller of the two Kettles (Kettle C) and retain this Kettle feature within the development. Wetland Mitigation Proposal for Placement of Fil! in the Large Keftle: Same requirements as Alternative 1. Wetland Mitigation Proposal for Placement of Fill in the Large Kettle: Wetland Mitigation Proposal for Placement of Fill in the Large Keftle: 17 Golf Terrace 1 building to have a restaurant, lounge, spa, conference and meeting rooms, chapel and billiards room. The Maritime Village building near Black Point RoadiU.S. Hwy 101 intersection would provide approximately'13,772 sq. ft. of retail/commercial space, including a restaurant and the relocated deli, grocery, convenience store from the marina upland area. Amenities (4): Golf Terrace 1 building would be the same as Alternative 1. The Maritime Village building near Black Point Road/U.S. Hwy 101 intersection would increase to approximately 20,608 sq. ft. of retail/commercial space, including a restaurant and the relocated deli, grocery, convenience store from the marina upland area. Amenities (4):Amenities (4): 18.Recreational Amenities (4) (in addition to the golf course, driving range and putting green): Renovated swimming pool in the marina upland area; two new swimming pools on the golf resort side, three hot tubs, three tennis courts, a Bocce ballcourt, billiard and game rooms, a common-use fire pit, and amphitheater. Walking paths throughout. Turn Building (Halfway House shown in graphics) not included in Alternative 1. Recreational Amenities (4) (in addltion to the golf course, driving range and putting green): One new swimming poolon the golf resort side, two tennis courts, a Bocce ballcourt, billiard and game rooms, a common-use fire pit, and amphitheater. Walking paths throughout. Turn Building (Halfway House shown in graphics) by Hole #9. Tree Top Adventure and Zip Line in the Maritime Village area. Recreationa! Amenities (4) 19.lmpervious Area: 13Yo lmpervious Area: 12o/o lmpervious Area: #ALTERNATTVE I (20{o- 20111 ALTERNATTVE 2 (2012',1 Alternative 3 (2015) EA Engineering, Science, and Technology,lnc,, PBC 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com drive proposed for transit access to U.S. Hwy 101. 12.Maintenance Building and Staff Quarters: Relocated this building along with the resort main entrance to the northeast corner of the site (adjacent to Black Point Road). 52 residential units proposed in the upper 2 stories of this structure. Maintenance Building and Staff Quarters: Same requirements as Alternative 1. Maintenance Building and Staff Quarters: 13.Domestic Water Supply Proposal: Ground water supply from on- site wells. Two options for second well location: west of Fairway 2 or west ol Fairuvay 7 (rather than west of Fairway 9) as a result of water right neqotiations. Domestic Water Supply Proposal: Ground water supply from on- site wells. Two options for second well location: east of Fairway 2 or west of Fairway 8. Domestic Water Supply Proposal: 14.Wastewater Recovery Plant (wRP): N utrient Removal Activated Sludge Process with Clarifiers and Class A Filtration proposed to produce Class A reclaimed water. WRP to be relocated to northwest corner of site. Effluent use during initial phases of development will include sprinkler irrigation in the native plant nursery and subsurface drain fields in the west area of the site until Kettle B is converted to a retention pond. Wastewater Recovery Plant (wRP): Same requirements as Alternative 1. Wastewater Recovery Plant (wRP): 15.Energy Proposa!: Electrical supply up to the limit of availability from Mason County PUD; on-site biodiesel co-generation, propane and geothermal sources proposed. Energy Proposal: Electrical supply up to the limit of availability from Mason County PUD; on-site propane and geothermal proposed. Energy Proposal: #ALTERNATTVE 1 (2010- 20111 ALTERNATTVE 2 (20121 Alternative 3 (2015) HT EA Engineering, Science, and Technology,lnc., PBG 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com areas would also occur. 8.Length of Project Roads Proposed: Overall length of project roads approximately 12,7 0O lf . Combined WDFW boat launch access road with Maritime Village access. Does not include approximately 1750 lf of combined golf cart, service road, EMS access through east side fairways. Length of Project Roads Proposed: Overall length of project roads approximately 13,750 lf. Relocated WDFW boat launch access road 1000 feet east of current location. Length of Project Roads Proposed: 9.Marina Access to/from Black Point Road: Construct the Marina Access Drive (12 ft. wide with turn outs) to be used for two way shuttle service and emergency vehicle access. Marina Access to/from Black Point Road: Same as Alternative 1 Marina Access to/from Black Point Road: 10.Main Entrance to the Golf Resort: Resort main entrance control gate relocated from previous plans to the northeast corner of the site with primary access from Black Point Road. U.S. Hwy 101 intersection realiqned further south. Main Entrance to the Golf Resort: Same requirements as Alternative 1. Main Entrance to the Golf Resort: 11.Provisions for Transit Service: Surface parking at the Black Point Road/U.S. Hwy 101 intersection signifi cantly revised compared to FEIS, due to relocation of the Marina Village residential units and approximately 13,772 sq. ft. of commercial development from the waterfront area to the intersection. Parking to be used by marina slip owners, resort visitors, and transit riders. Bus stop and bus loop Provisions for Transit Service: Surface parking at the Black Point Road/U.S. Hwy 101 intersection revised slightly from Alternative 1. 20,608 sq. ft. of commercial development from the waterfront area to the intersection. Parking to be used by marina slip owners, resort visitors, and transit riders. Bus stop and bus loop drive proposed for transit access to U.S. Hwy 't01. Provisions for Transit Service: #ALTERNATTVE I (20{0- 20111 ALTERNATTVE 2 (2012t Alternative 3 (2015) Lt EA Enorneerrno-Ef,l ;=- :'-:-;: =--'- - DB3 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com Retain Existing Pleasant Harbor House Retain Existing Bed and Breakfast House (owned by others) waterfront.Retain Existing Bed and Breakfast House (owned by others) 5.Short Term Stay vs. Long Term Stay Units:* Short Term Tourist Residential Units: 560 (67%) Long Term Tourist Residential Units: 278 (33%) Short Term Stay vs. Long Term Stay Units: Short Term Tourist Residential Units: 560 (67%) Long Term Tourist Residential Units: 278 (33%) Short Term Stay vs. Long Term Stay Units: 6.Commercial Development Proposed: Golf Resort: 36,000 sq. ft. Maritime Village: 13,772 sq. ft. TotalCommercial Development: 49,772 sq. ft. Gommercial Development Proposed: Golf Resort: 36,000 sq. ft. Maritime Village: 20,608 sq. ft. TotalCommercial Development: 56,608 sq. ft. Gommercia! Development Proposed: 7 Proximity of Structures to Pleasant Harbor OHWM: Modified earlier plan to relocate all proposed residential units outside the 150 ft. Shoreline buffer proposed in the County's locally-approved Shoreli ne Master Program update. Existing structures at the waterfront to be repaired and replaced with in existing footprints under a pre-existing Binding Site Plan, outside of this SEIS. No new buildings are proposed in this area, with the exception of a storage building approved under the existing Binding Site Plan. Repair and widening of existing roadways and reconfiguration of parkinq Proximity of Structures to Pleasant Harbor OHWM: Same as Alternative 1. Proximity of Structures to Pleasant Harbor OHWM: #ALTERNATTVE 1 (2010- 2Afil ALTERNATTVE 2 e012t Alternative 3 (2015) EA Engineering, Science, and Technology, lnc., PBC 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com Golf Resort: Golf Terraces: Four buildings, 4 stories (47 ft.9 inches in height; 724,000 sq. ft.) Golf Vistas: Thirteen buildings, 2 stories (27 ft.9 inches in height; 123,000 sq.ft.) Sea View Villas: Thirty-one buildings, 1 story (28 ft. 5 inches in height; 371,400 sq. ft.) Maintenance Building and Staff Quarters; One building, 3 stories (39 ft.; 87,000 sq. ft.) Maritime Village: Maritime Village Building: One building, 3 stories (39 ft. height; 71,886 sq. fi.) Reunion House and Harbor View House:Two buildings, 3 stories (39 ft. height; each 8,892 sq. ft.) Existing Pleasant Harbor House: One building, 1 story Existing Bed and Breakfast House: One building, to remain (counted as one residential unit) Golf Resort: Golf Terraces: Four buildings, 5 stories (58 ft. I inches to 70 ft. in height; 612,674 sq.ft.) Golf Vista: Five buildings,2 stories (27 fl.4 inches in height; 71,280 sq. ft.) Sea View Villas: 23 buildings, 1 story (28 ft. 5 inches in height; 382,542 sq.ft.) Maintenance Building and Staff Quarters: One building, 3 stories (39 ft.; 87,000 sq.ft.) Maritime Village: Maritime Village Building: One building, 3 stories (52 ft. 3 inches height, 72,453 sq. ft.) Existing Pleasant Harbor House: One building 1 story (same as Alternative 1) Existing Bed and Breakfast House: One building to remain (counted as one residential unit). Maritime Village: Golf Resort: Number and Type of Residential Units Proposed within the Maritime Village: Maritime Village Building: 62 units located up the hillside away from the waterfront. Retain Existing Pleasant Harbor House - same as Alternative 1 Number and Type of Residential Units Proposed within the Maritime Village: 4.Number and Type of Residential Units Proposed within the Maritime Village: Maritime Village Building: 36 units located up the hillside away from the waterfront Reunion House and Harbor View House: 24 units in two buildings located up the hillside away from the #ALTERNATTVE 1 (20{0- 20111 ALTERNATTVE 2 (20121 Alternative 3 (2015) HT EA Engineering, Science, and Technology,lnc., PBC 2200 Sixth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com Craig Pecko Describe proposed stormwater management system. Please coordinate completion of the chart below for Alternative 3. As indicated above, it is anticipated that many of the Alternative 3 project elements would be the same as under Alternative 2. Please confirm those elements that would be the same and project elements that would differ under Alternative 3 from Alternative 2. 1 Total New Buildings 55 Number of Buildings and Units: Golf Resort: Fifty-two buildings, 828 residential units Maritime Village: Three new buildings, 60 new residential units Existing Buildings lncluded ln MPR 890-Unit Count: Pleasant Harbor House - 1 Bed and Breakfast House - 1 Total New Buildings: 37 Number of Buildings and Units: Golf Resort: Thirty-six buildings, 822 residential units Maritime Village: One new building, 66 new residential units Existing Buildings lncluded ln MPR 890-Unit Count: Pleasant Harbor House - 1 Bed and Breakfast House - 1 Number of Buildings and Units: 2.Building Types and Units: Golf Resort: Golf Terraces: 500 units Golf Vistas: 76 units Sea View Villas: 200 units Maintenance Building and Staff Quarters: 52 units Maritime Village: Maritime Village Building: 36 units Reunion House: 12 units HarborView House: 12 units Building Types and Units: Golf Resort: Golf Terraces: 520 units Alpine Vistas: 44 units Sea View Villas: 206 units Maintenance Building and Staff Quarters: 52 units Maritime Village: Maritime Village Building: 66 units Building Types and Units: 3.Building Heights and Square Footage: Building Heights and Square Footage: Building Heights and Square Footage: #ALTERNATTVE 1 (2010- 20111 ALTERNATTVE 2 QA12l Alternative 3 (2015) $,\HT EA Engineering, $cience, and Technology,lnc., PBC JUL u e il6 ffft$s$llt[til{T{ [t'' 2200 Slxth Avenue, Suite 707 Seattle, WA 98121 www.eaest.com July 29, 2015 TNFORMATTON NEEDS FOR NEW SEIS ALTERNATTVE (ALTERNATTVE 3) Pleasant Harbor Final SEIS Following is a general list of information needed to add a new Alternative (Alternative 3) to the SEIS, together with information needs from specific consultants. We understand that this alternative will generally be similar to Alternative 2 in terms of housing units and commercial space, with the primary difference being a smaller, 9-hole golf course that will require less grading and clearing on the site. -Figures Needed o Detailed Site Plan. Grading Plan. Aquifer recharge (Bender) GeoEngineers. Overview of plants and animals impacts, assumed to be less than Alt. 2 due to less grading and clearing occurring.. Wetland impacts, wetland mitigation plan (confirm same as Alt 2?) Scott Bender. Water demand (less than Alt. 2 due to less golf course development?). Aquifer recharge discussion. Please complete the below chart for Alternative 3 Annual Recha to uifer Under Alternatives 1-3 Existi Conditions (Acre-feet) Alternative 1 (Acre-feet) Alternative 2 (Acre-feet) Alt 3. TotalAnnual Rainfall 1,189 1,189 1,189 1,189 (Minus Actual Evapotranspiration) 430 3222 3492 (Minus Pond Evaporation)I 11 (Minus Consumptive Use)ol 1213 1213 (Minus lrrisation)120 120 Plus Wastewater Generated 121 121 Plus lmpervious Runoff 102 94 TotalAquifer Recharqe 759 840 804 Michelle Farfan From: Sent: To: Cc: Subject: Attachments: Hollinger, Kristy < khollinger@eaest.com> Wednesday, )uly 29,2015 2:23 PM ' peckassoc@comcast.net'; David W. Joh nson (djoh nson @co jefferson.wa.us) Schipanski, Rich Pleasant Harbor Info Needs for New Alternative Alt 3 - Pleasant Harbor Info Needs.pdf Hi Craig, As per your request, attached is a list of info and figures that we will need in order to incorporate a new alternative into the Final SEIS. We are assuming that you will be coordinating with Scott Bender and GeoEngineers for items in their areas. Please let meknowifyouneedanyassistancewithanything. lnordertokeeponscheduletopublishtheFinalSE|Sbytheendof August, it would be good to receive this within a week, by August 5th. Thanks! Kristy Kristy M. Hollinger Planner E[t EA Engineering, Science and Technology, lnc., PBC 2200 Sinh Ave, Suite 707 | Seattle, WA 98121 (t) 206.452.5350 ext. '1726 | (0 206.443.7646 khollinser@eaest.com http://www.eaest,com .a fl e"rot" printing. think about ENVIRoNMEI{TAL responsibility 1