Window, Skylight and Door Schedule
Project Information Contact Information
Width Height
Ref.U-factor Qt.Feet Inch Feet Inch Area UA
Exempt Swinging Door (24 sq. ft. max.)0.28 1 2 8 8 21.3 5.97
0.0 0.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA
0.24 1 8 8 64.0 15.36
0.24 3 3 2 18.0 4.32
0.24 2 2 6 6 4 31.7 7.60
0.24 3 3 6 4 57.0 13.68
0.23 1 3 9 27.0 6.21
0.24 4 4 1 16.0 3.84
0.24 1 1 7 6 7.5 1.80
0.24 1 1 5 5.0 1.20
0.24 1 3 5 15.0 3.60
0.24 1 8 1 8.0 1.92
0.24 2 2 6 5 25.0 6.00
0.24 2 2 7 6 30.0 7.20
0.25 1 3 6 5 17.5 4.38
0.25 2 3 6 4 38.0 9.50
0.23 1 3 4 12.0 2.76
0.24 7 3 5 105.0 25.20
0.24 1 2 6 5 12.5 3.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.32 1 3 6 8 28.0 8.96
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Exempt Glazed Fenestration (15 sq. ft. max.)
Thermatru 3/4 glass entry door
HV below PW
Casement
Single Hung
Single Hung
Picture Window
Picture Window
Picture Window
Picture Window
XO Slilder
Picture Window
Picture Window 3-high
Picture Window
Picture Window
Picture Window
Andrew Reed & Marilyn Meyer Anderson Homes / Carla Sebastian
____ Belvedere Drive 80 Murray Court
Port Townsend, WA 98368 Sequim, WA 98382
SGD
Picture Window
Picture Window
RECEIVED BY DCD 10/13/21
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Vertical Fenestration Area and UA 517.2 126.53
Vertical Fenestration Area Weighted U = UA/Area 0.24
Overhead Glazing (Skylights)
Component Width Height
Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA
0.50 2 2 2 8.0 4.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 8.0 4.00
Overhead Glazing Area Weighted U = UA/Area 0.50
546.5 136.50Total Sum of Fenestration Area and UA (for heating system sizing calculations)
Crystalite Skylights
RECEIVED BY DCD 10/13/21
AI.R F40
HEATING CO.
INDOOR AIR EXPERTS
Load Short Fonn
Entire House
Air Flo Heating Co
Job:
Date: August 31, 2021
By:
221 West Cedar Street, Sequim, WA98382 Pbore: 360.683.7746 Fax 360.683.3971 Web: wwwairtloheatirg.com
Project Information
For: Meyers (Anderson Homes)
WA
Design Information
Infiltration
Outside db (°F)
Inside db (°F)
Design TD (°F)
Daily range
Inside humidity(%)
Moisture difference (gr/lb)
Htg
23
70
47
30
19
Clg
76
75
1
M
50
15
Method
Construction quality
Fireplaces
Simplified
Tight
0
HEATING EQUIPMENT COOLING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
Capacity balance point= 0 °F
Backup:
0HSPF
0 Btuh@47°F
0 °F
1000 cfm
0.023 cfm/Btuh
0 in H2O
Make
Trade
Cond
Coil
AHRI ref
Efficiency
Sensible cooling
Latent cooling
Total cooling
Actual airflow
Air flow factor
Static pressure
Load sensible heat ratio
0SEER
0 Btuh
0 Btuh
0 Btuh
1000 cfm
0.064 cfm/Btuh
0 in H2O
0.96
lnout - 6 kW n11tn11t - 21.1A2 Bl 1h 1nnAFUE
ROOM NAME Area Htg load Clg load HtgAVF ClgAVF
(fr') (Btuh) (Btuh) (cfm) (cfm)
Main Floor 1238 23604 9321 533 595
Upper Floor 1253 20676 6348 467 405
Entire House 2491 44280 15668 1000 1000
Other equip loads 0 0
Equip.@ 0.81 RSM 12691
Latent cooling 655
"')JI0-1 AA'")On -1"l"l.A~ ... """ TOTALS 2491 44280 13346 1000 1000
BolcV'ltalic values have been manually overridden
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
,.._ -Pl,,t- vvrightsoft•• . . .
;::::;_ ""''•'""''"'"'"""""·"•'·""'""' R1ght-Sute®Urwersal 2021 21.0.03 RSU02757
AC C~ ... ompany\Wrighlsoft HVAC\Project\Defaut 2021.rup Cale= MJ8 Front Door faces: N
2021-Aug-3113:23:54
Page 1
RECEIVED BY DCD 10/13/21
Professional Ultra™ Hybrid Electric is the most
efficient water heater available
Professional Ultra
Hybrid
50, 65 and 80-Gallon Capacities
208-240 Volt / 1 PH
Electric
LEED Points = 3
Efficiency
• High 3.55 - 3.70 UEF reduces
operating cost
• ENERGY STAR® rated
Performance
• Delivers hot water faster than most
standard electric water heaters –
67 gallons first-hour delivery for
50-gallon model, 75 gallons FHD for
65-gallon model and 89 gallons FHD
for 80-gallon model
• Ambient operating range: 37-145° F
is widest in class, offering more days
of HP operation annually; designed to
meet Northern Climate Spec (Tier 3)
Easy Installation
• Easy access side connections
• Quick access to electrical junction box
• Easily replaces a standard electric
water heater
Integration
• LCD Screen with built-in water
sensor alert with audible alarm
• Integrated EcoNet® WiFi- connected*
technology and free mobile app gives
users control over water systems,
allowing for customizable temperature,
vacation settings, energy savings and
system monitoring at home or away.
Visit Ruud.com/hybridsolutions
• Water sensor detects water outside
of the unit and sends an alert via the
free Ruud EcoNet® mobile app to the
homeowner
Operation Modes
• Energy Saver
• Heat Pump
• High Demand
• Electric
• Vacation: 2-28 days (or placed on
hold indefinitely)
Plus…
• Premium grade anode rod with
resistor extends the life of the tank
• 3/4" NPT water inlet and outlet;
3/4" condensate drain connections
• Incoloy stainless steel resistor
elements
• Dry-fire protection
• Easy access, top mounted washable
air filter
• 2" Non-CFC foam insulation
• Enhanced flow brass drain valve
• Temperature and pressure relief valve
installed
• Design certified to NSF/ANSI 372
(Lead Content)
Warranty
• 10-Year limited tank and parts
warranty
See Residential Warranty Certificate for complete
information
Units meet or exceed ANSI requirements and have
been tested according to D.O.E. procedures. Units
meet or exceed the energy efficiency requirements
of NAECA, ASHRAE standard 90, ICC Code and all
state energy efficiency performance criteria.
* WiFi broadband internet connection required.
See specifications chart on next page.
Ruud Residential Electric Professional Ultra
Hybrid Water Heaters
Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com
PRINTED IN U.S.A. 06/19 WP FORM NO. HPR-350-6 Rev. 5
15 and
30 Amps
RECEIVED BY DCD 10/13/21
Professional Ultra™ Hybrid Specifications
2
Estimated energy cost based on a national average electricity cost of $0.12 /kWh. Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements.
All units have integrated WiFi control board.
-A-
AirInlet
Hot WaterOutlet
CondensateDrain
PressureReliefValve
WaterInlet
ColdAirExhaust
(Ducting Attached)
12” Minimum LengthInsulated Flex Duct Requiredfor Vibration Isolation
6” Clearance for AirFilter Maintenance
2” ClearanceNeeded for T&PRelease
Door with Louvers)
Ducting over filterNo Ducting Ducting Straight through
IH
B
E
A
C
D
K L
J
F
G J
2”
12”12”
DESCRIPTION DIMENSIONS (SHOWN IN INCHES)
NOMINAL
GALLON
CAPACITY
MODEL
NUMBER A B C D E F G H I J K L
50 PROUH50 61 22-1/4 47 3-5/8 39-5/8 28 24 36 50 27 77 73
65 PROUH65 64 24-1/4 49 3-7/8 42-3/8 30 26 38 52 29 80 76
80 PROUH80 74 24-1/4 59 3-7/8 52-3/8 30 26 38 52 29 90 86
DESCRIPTION ENERGY INFO FEATURES TANK DIMENSIONS
(SEE SPACE REQUIREMENTS IN DIAGRAMS BELOW)
NOMINAL
GALLON
CAPACITY
RATED
GALLON
CAPACITY
MODEL
NUMBER
MODEL
VARIANT
ELECTRIC
BREAKER
SIZE
UNIFORM
ENERGY
FACTOR
(UEF)
EST.
YEARLY
ENERGY
COST
ELEMENT
WATTAGE
COMPRES-
SOR
BTU/H
SOUND
LEVEL
(dBA)
UEF
FIRST HR.
RATING
G.P.H.
RECOVERY
IN G.P.H
90° F RISE
HEIGHT
A
DIAM.
B
HT. TO
COLD
INLET &
DRAIN VALVE
HT. TO
HOT
OUTLET
& T&P
UNIT
WT.
(LBS)
APPROX.
SHIP WT.
(LBS.)
50 45 PROUH50 T2 RU350 DCB 692104 30 3.55 $110 5,000 4200 49 67 29 61" 22-1/4" 3-5/8" 39-5/8" 178 218
50 45 PROUH50 T2 RU350 D 694030 15 3.55 $110 2,250 4200 49 53 16 61" 22-1/4" 3-5/8" 39-5/8" 178 218
65 59 PROUH65 T2 RU350 DCB 692111 30 3.70 $161 5,000 4200 49 75 29 64" 24-1/4" 3-7/8" 42-3/8" 225 262
65 59 PROUH65 T2 RU350 D15 694146 15 3.55 $110 2,250 4200 49 53 16 64" 24-1/4" 3-7/8" 42-3/8" 225 262
80 72 PROUH80 T2 RU350 DCB 692128 30 3.70 $161 5,000 4200 49 89 29 74" 24-1/4" 3-7/8" 52-3/8" 244 281
80 72 PROUH80 T2 RU350 D15 694054 15 3.55 $110 2,250 4200 49 65 16 74" 24-1/4" 3-7/8" 52-3/8" 244 281
RECEIVED BY DCD 10/13/21
3
Heater: Not Ducted
Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10').
Requirements: No additional ventilation needed.
Heater: Ducted with inlet OR outlet duct
Room size: Any size room
Requirements: Air gap under door equal to 18 in2
(0.75” clearance)
Heater: Ducted with inlet AND outlet duct
Room size: Any size room
Requirements: No additional ventilation needed.
Heater: Not Ducted
Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10').
Requirements: Full louvered door OR two louvers
top and bottom. See below.
Heater: Not Ducted
Room: Small Closet
Requirements: * Air gap under door equal to 18 in2 (0.75” clearance).
* Louver must be located the same height on door as
the air exhaust on heater.
* Heater air exhaust must be positioned towards louver
within one foot of door.
24”
12” Max Door
Air exhaust
.75”
24”.75”
Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency
RECEIVED BY DCD 10/13/21
Ruud Residential Electric Professional Ultra
Hybrid Water Heaters
Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com
PRINTED IN U.S.A. 06/19 WP FORM NO. HPR-350-6 Rev. 5
In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice.
4
PART NUMBER DESCRIPTION USE FOR
SP20882 Earthquake Isolation Kit Installations in seismic regions
SP20883 Vibration Isolation Kit Installation on non-concrete floors
SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter
SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter
SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter
SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter
SP20888 8" Ruud Approved Damper Kit Exhaust only to the outside ducting configuration (no inlet duct)
SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting
SP20890 Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized
Hybrid Accessories
SP20882
SP20885
SP20888
SP20883
SP20886
SP20889
SP20884
SP20887
SP20890
RECEIVED BY DCD 10/13/21