Loading...
HomeMy WebLinkAboutBLD2021-00599 - 03 Energy WorksheetR E C E I V E D B Y D C D 1 0 / 1 3 / 2 1 R E C E I V E D B Y D C D 1 0 / 1 3 / 2 1 R E C E I V E D B Y D C D 1 0 / 1 3 / 2 1 Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref.U-factor Qt.Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.28 1 2 8 8 21.3 5.97 0.0 0.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.24 1 8 8 64.0 15.36 0.24 3 3 2 18.0 4.32 0.24 2 2 6 6 4 31.7 7.60 0.24 3 3 6 4 57.0 13.68 0.23 1 3 9 27.0 6.21 0.24 4 4 1 16.0 3.84 0.24 1 1 7 6 7.5 1.80 0.24 1 1 5 5.0 1.20 0.24 1 3 5 15.0 3.60 0.24 1 8 1 8.0 1.92 0.24 2 2 6 5 25.0 6.00 0.24 2 2 7 6 30.0 7.20 0.25 1 3 6 5 17.5 4.38 0.25 2 3 6 4 38.0 9.50 0.23 1 3 4 12.0 2.76 0.24 7 3 5 105.0 25.20 0.24 1 2 6 5 12.5 3.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.32 1 3 6 8 28.0 8.96 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Exempt Glazed Fenestration (15 sq. ft. max.) Thermatru 3/4 glass entry door HV below PW Casement Single Hung Single Hung Picture Window Picture Window Picture Window Picture Window XO Slilder Picture Window Picture Window 3-high Picture Window Picture Window Picture Window Andrew Reed & Marilyn Meyer Anderson Homes / Carla Sebastian ____ Belvedere Drive 80 Murray Court Port Townsend, WA 98368 Sequim, WA 98382 SGD Picture Window Picture Window RECEIVED BY DCD 10/13/21 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 517.2 126.53 Vertical Fenestration Area Weighted U = UA/Area 0.24 Overhead Glazing (Skylights) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.50 2 2 2 8.0 4.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 8.0 4.00 Overhead Glazing Area Weighted U = UA/Area 0.50 546.5 136.50Total Sum of Fenestration Area and UA (for heating system sizing calculations) Crystalite Skylights RECEIVED BY DCD 10/13/21 AI.R F40 HEATING CO. INDOOR AIR EXPERTS Load Short Fonn Entire House Air Flo Heating Co Job: Date: August 31, 2021 By: 221 West Cedar Street, Sequim, WA98382 Pbore: 360.683.7746 Fax 360.683.3971 Web: wwwairtloheatirg.com Project Information For: Meyers (Anderson Homes) WA Design Information Infiltration Outside db (°F) Inside db (°F) Design TD (°F) Daily range Inside humidity(%) Moisture difference (gr/lb) Htg 23 70 47 30 19 Clg 76 75 1 M 50 15 Method Construction quality Fireplaces Simplified Tight 0 HEATING EQUIPMENT COOLING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point= 0 °F Backup: 0HSPF 0 Btuh@47°F 0 °F 1000 cfm 0.023 cfm/Btuh 0 in H2O Make Trade Cond Coil AHRI ref Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio 0SEER 0 Btuh 0 Btuh 0 Btuh 1000 cfm 0.064 cfm/Btuh 0 in H2O 0.96 lnout - 6 kW n11tn11t - 21.1A2 Bl 1h 1nnAFUE ROOM NAME Area Htg load Clg load HtgAVF ClgAVF (fr') (Btuh) (Btuh) (cfm) (cfm) Main Floor 1238 23604 9321 533 595 Upper Floor 1253 20676 6348 467 405 Entire House 2491 44280 15668 1000 1000 Other equip loads 0 0 Equip.@ 0.81 RSM 12691 Latent cooling 655 "')JI0-1 AA'")On -1"l"l.A~ ... """ TOTALS 2491 44280 13346 1000 1000 BolcV'ltalic values have been manually overridden Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. ,.._ -Pl,,t- vvrightsoft•• . . . ;::::;_ ""''•'""''"'"'"""""·"•'·""'""' R1ght-Sute®Urwersal 2021 21.0.03 RSU02757 AC C~ ... ompany\Wrighlsoft HVAC\Project\Defaut 2021.rup Cale= MJ8 Front Door faces: N 2021-Aug-3113:23:54 Page 1 RECEIVED BY DCD 10/13/21 Professional Ultra™ Hybrid Electric is the most efficient water heater available Professional Ultra Hybrid 50, 65 and 80-Gallon Capacities 208-240 Volt / 1 PH Electric LEED Points = 3 Efficiency • High 3.55 - 3.70 UEF reduces operating cost • ENERGY STAR® rated Performance • Delivers hot water faster than most standard electric water heaters – 67 gallons first-hour delivery for 50-gallon model, 75 gallons FHD for 65-gallon model and 89 gallons FHD for 80-gallon model • Ambient operating range: 37-145° F is widest in class, offering more days of HP operation annually; designed to meet Northern Climate Spec (Tier 3) Easy Installation • Easy access side connections • Quick access to electrical junction box • Easily replaces a standard electric water heater Integration • LCD Screen with built-in water sensor alert with audible alarm • Integrated EcoNet® WiFi- connected* technology and free mobile app gives users control over water systems, allowing for customizable temperature, vacation settings, energy savings and system monitoring at home or away. Visit Ruud.com/hybridsolutions • Water sensor detects water outside of the unit and sends an alert via the free Ruud EcoNet® mobile app to the homeowner Operation Modes • Energy Saver • Heat Pump • High Demand • Electric • Vacation: 2-28 days (or placed on hold indefinitely) Plus… • Premium grade anode rod with resistor extends the life of the tank • 3/4" NPT water inlet and outlet; 3/4" condensate drain connections • Incoloy stainless steel resistor elements • Dry-fire protection • Easy access, top mounted washable air filter • 2" Non-CFC foam insulation • Enhanced flow brass drain valve • Temperature and pressure relief valve installed • Design certified to NSF/ANSI 372 (Lead Content) Warranty • 10-Year limited tank and parts warranty See Residential Warranty Certificate for complete information Units meet or exceed ANSI requirements and have been tested according to D.O.E. procedures. Units meet or exceed the energy efficiency requirements of NAECA, ASHRAE standard 90, ICC Code and all state energy efficiency performance criteria. * WiFi broadband internet connection required. See specifications chart on next page. Ruud Residential Electric Professional Ultra Hybrid Water Heaters Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com PRINTED IN U.S.A. 06/19 WP FORM NO. HPR-350-6 Rev. 5 15 and 30 Amps RECEIVED BY DCD 10/13/21 Professional Ultra™ Hybrid Specifications 2 Estimated energy cost based on a national average electricity cost of $0.12 /kWh. Uniform Energy Factor and rated gallon capacity based on Department of Energy (DOE) requirements. All units have integrated WiFi control board. -A- AirInlet Hot WaterOutlet CondensateDrain PressureReliefValve WaterInlet ColdAirExhaust (Ducting Attached) 12” Minimum LengthInsulated Flex Duct Requiredfor Vibration Isolation 6” Clearance for AirFilter Maintenance 2” ClearanceNeeded for T&PRelease Door with Louvers) Ducting over filterNo Ducting Ducting Straight through IH B E A C D K L J F G J 2” 12”12” DESCRIPTION DIMENSIONS (SHOWN IN INCHES) NOMINAL GALLON CAPACITY MODEL NUMBER A B C D E F G H I J K L 50 PROUH50 61 22-1/4 47 3-5/8 39-5/8 28 24 36 50 27 77 73 65 PROUH65 64 24-1/4 49 3-7/8 42-3/8 30 26 38 52 29 80 76 80 PROUH80 74 24-1/4 59 3-7/8 52-3/8 30 26 38 52 29 90 86 DESCRIPTION ENERGY INFO FEATURES TANK DIMENSIONS (SEE SPACE REQUIREMENTS IN DIAGRAMS BELOW) NOMINAL GALLON CAPACITY RATED GALLON CAPACITY MODEL NUMBER MODEL VARIANT ELECTRIC BREAKER SIZE UNIFORM ENERGY FACTOR (UEF) EST. YEARLY ENERGY COST ELEMENT WATTAGE COMPRES- SOR BTU/H SOUND LEVEL (dBA) UEF FIRST HR. RATING G.P.H. RECOVERY IN G.P.H 90° F RISE HEIGHT A DIAM. B HT. TO COLD INLET & DRAIN VALVE HT. TO HOT OUTLET & T&P UNIT WT. (LBS) APPROX. SHIP WT. (LBS.) 50 45 PROUH50 T2 RU350 DCB 692104 30 3.55 $110 5,000 4200 49 67 29 61" 22-1/4" 3-5/8" 39-5/8" 178 218 50 45 PROUH50 T2 RU350 D 694030 15 3.55 $110 2,250 4200 49 53 16 61" 22-1/4" 3-5/8" 39-5/8" 178 218 65 59 PROUH65 T2 RU350 DCB 692111 30 3.70 $161 5,000 4200 49 75 29 64" 24-1/4" 3-7/8" 42-3/8" 225 262 65 59 PROUH65 T2 RU350 D15 694146 15 3.55 $110 2,250 4200 49 53 16 64" 24-1/4" 3-7/8" 42-3/8" 225 262 80 72 PROUH80 T2 RU350 DCB 692128 30 3.70 $161 5,000 4200 49 89 29 74" 24-1/4" 3-7/8" 52-3/8" 244 281 80 72 PROUH80 T2 RU350 D15 694054 15 3.55 $110 2,250 4200 49 65 16 74" 24-1/4" 3-7/8" 52-3/8" 244 281 RECEIVED BY DCD 10/13/21 3 Heater: Not Ducted Room size: Larger than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: No additional ventilation needed. Heater: Ducted with inlet OR outlet duct Room size: Any size room Requirements: Air gap under door equal to 18 in2 (0.75” clearance) Heater: Ducted with inlet AND outlet duct Room size: Any size room Requirements: No additional ventilation needed. Heater: Not Ducted Room size: Smaller than 700 ft3 (e.g. 7' x 10' x 10'). Requirements: Full louvered door OR two louvers top and bottom. See below. Heater: Not Ducted Room: Small Closet Requirements: * Air gap under door equal to 18 in2 (0.75” clearance). * Louver must be located the same height on door as the air exhaust on heater. * Heater air exhaust must be positioned towards louver within one foot of door. 24” 12” Max Door Air exhaust .75” 24”.75” Hybrid Water Heater Installation Guidelines to Provide Optimal Efficiency RECEIVED BY DCD 10/13/21 Ruud Residential Electric Professional Ultra Hybrid Water Heaters Ruud Water Heating • 1115 Northmeadow Parkway, Suite 100, Roswell, Georgia 30076 • www.ruud.com PRINTED IN U.S.A. 06/19 WP FORM NO. HPR-350-6 Rev. 5 In keeping with its policy of continuous progress and product improvement, Ruud reserves the right to make changes without notice. 4 PART NUMBER DESCRIPTION USE FOR SP20882 Earthquake Isolation Kit Installations in seismic regions SP20883 Vibration Isolation Kit Installation on non-concrete floors SP20884 8" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 8" diameter SP20885 7" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 7" diameter SP20886 6" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 6" diameter SP20887 5" Diameter UL Certified Termination Kit Termination to the outside or to the attic with 5" diameter SP20888 8" Ruud Approved Damper Kit Exhaust only to the outside ducting configuration (no inlet duct) SP20889 25' Flexible 8" Diameter Duct Kit For up to 25' of ducting SP20890 Rigid Elbow Duct Kit Installation in tight places where space needs to be minimized Hybrid Accessories SP20882 SP20885 SP20888 SP20883 SP20886 SP20889 SP20884 SP20887 SP20890 RECEIVED BY DCD 10/13/21