Washington State Energy Code Application
Prepared by: Bushnell Energy Consulting
RESNET Rater ID: 3124142
RESNET Provider:
WSU Energy Program Provider ID: 1998-100
The Refuge Resort & Conference Center
Owners: Jim & Robbie Edgren
Job Site: 2275 Duckabush Rd. Brinnon, WA
WSEC application for the Chapel_ Non-Occupancy Building
WSEC SECTION R402
BUILDING THERMAL ENVELOPE:
R402.1 General (Prescriptive). The building thermal envelope shall meet the requirements of Sections
R402.1.1 through R402.1.6.
Exception: Any conditioned space not intended for occupancy.
Request for interpretation submitted to Jefferson County 11-14-2021
∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞
A similar, not intended for occupancy, Recreational Building in Thurston County was interpreted as
follows:
This Recreational Building, which is not intended for occupancy, needs to comply with the general
requirements of WSEC Section R402.1 for Building Thermal Envelopes. It does not need to comply with
the Energy Credits of Table’s R406.2 & R406.3.
9/22/2021 interpretation from Thurston County Plans Examiner, Tim Rubert.
RECEIVED BY DCD 12/6/2021
Window, Skylight and Door Schedule
Project Information Contact Information
Width Height
Ref.U-factor Qt.Feet Inch Feet Inch Area UA
Exempt Swinging Door (24 sq. ft. max.)0.40 1 2 6 6 8 16.7 6.67
0.40 1 2 6 5 0 12.5 5.00
Vertical Fenestration (Windows and doors)
Component Width Height
Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA
0.30 10 2 0 6 0 120.0 36.00
0.30 1 2 6 5 0 12.5 3.75
0.30 2 3 6 4 4 30.3 9.10
0.30 10 1 3 1 3 15.6 4.69
0.30 2 2 0.3 2 0.3 8.2 2.45
0.30 2 1 9 1 9 6.1 1.84
0.30 1 4 0 8 0 32.0 9.60
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Energy Refuge Chapel Quadra Engineering_Harold Andersen P.E.
2275 Duckabush Rd. Brinnon, WA 98320 (360) 379-9117
NFRC Rated Window
NFRC Rated Window
NFRC Rated Window
NFRC Rated 1/2 round Window Top
NFRC Rated 1/2 round Window Top
NFRC Rated 1/2 round Window Top
NFRC Rated Door
Exempt Glazed Fenestration (15 sq. ft. max.)
RECEIVED BY DCD 12/6/2021
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Vertical Fenestration Area and UA 224.8 67.43
Vertical Fenestration Area Weighted U = UA/Area 0.30
Overhead Glazing (Skylights)
Component Width Height
Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
0.0 0.00
Sum of Overhead Glazing Area and UA 0.0 0.00
Overhead Glazing Area Weighted U = UA/Area 0.00
253.9 79.09Total Sum of Fenestration Area and UA (for heating system sizing calculations)
RECEIVED BY DCD 12/6/2021
Simple Heating System Size: Washington State
Project Information Contact Information
Heating System Type:
To see detailed instructions for each section, place your cursor on the word "Instructions"
Design Temperature
Instructions Design Temperature Difference (∆T)47
∆T = Indoor (70 degrees) - Outdoor Design Temp
Area of Building
Conditioned Floor Area
Instructions Conditioned Floor Area (sq ft)817
Average Ceiling Height Conditioned Volume
Instructions Average Ceiling Height (ft)13.2 10,784
Glazing and Doors U-Factor X Area =UA
Instructions 0.300 254 76.17
Skylights U-Factor X Area =UA
Instructions 0.50 ---
Insulation
Attic U-Factor X Area =UA
Instructions 0.026 49 1.27
Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA
Instructions 0.027 922 24.88
Above Grade Walls (see Figure 1)U-Factor X Area UA
Instructions 0.056 1,198 67.09
Floors U-Factor X Area UA
Instructions No selection ---
Below Grade Walls (see Figure 1)U-Factor X Area UA
Instructions No selection ---
Slab Below Grade (see Figure 1)F-Factor X Length UA
Instructions No selection ---
Slab on Grade (see Figure 1)F-Factor X Length UA
Instructions 0.360 126 45.36
Location of Ducts
Instructions Duct Leakage Coefficient
1.00
Sum of UA 214.78
Envelope Heat Load 10,095 Btu / Hour
Sum of UA x ∆T
Air Leakage Heat Load 5,474 Btu / Hour
Volume x 0.6 x ∆T x 0.018
Building Design Heat Load 15,569 Btu / Hour
Air leakage + envelope heat loss
Building and Duct Heat Load 15,569 Btu / Hour
Ducts in unconditioned space: sum of building heat loss x 1.10
Ducts in conditioned space: sum of building heat loss x 1
Maximum Heat Equipment Output 19,461 Btu / Hour
Building and duct heat loss x 1.40 for forced air furnace
Building and duct heat loss x 1.25 for heat pump
This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA
Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads.
Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some
values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at
energycode@energy.wsu.edu or (360) 956-2042 for assistance.
Energy Refuge Chapel
2275 Duckabush Rd. Brinnon, WA 98320
Quadra Engineering_Harold Andersen P.E.
(360) 379-9117
Above Grade
Below Grade
Figure 1.
All Other Systems Heat Pump
(07/01/13)
RECEIVED BY DCD 12/6/2021