HomeMy WebLinkAboutBLD2021-00721_03 Energy Worksheet1407 S Ferdinand Dr, Tacoma, WA 98405 • 253.549.5858 • www.bushnellenergyconsulting.com Washington State Energy Code Application Prepared by: Bushnell Energy Consulting RESNET Rater ID: 3124142 RESNET Provider: WSU Energy Program Provider ID: 1998-100 The Refuge Resort & Conference Center Owners: Jim & Robbie Edgren Job Site: 2275 Duckabush Rd. Brinnon, WA WSEC application for the Chapel_ Non-Occupancy Building WSEC SECTION R402 BUILDING THERMAL ENVELOPE: R402.1 General (Prescriptive). The building thermal envelope shall meet the requirements of Sections R402.1.1 through R402.1.6. Exception: Any conditioned space not intended for occupancy. Request for interpretation submitted to Jefferson County 11-14-2021 ∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞∞ A similar, not intended for occupancy, Recreational Building in Thurston County was interpreted as follows: This Recreational Building, which is not intended for occupancy, needs to comply with the general requirements of WSEC Section R402.1 for Building Thermal Envelopes. It does not need to comply with the Energy Credits of Table’s R406.2 & R406.3. 9/22/2021 interpretation from Thurston County Plans Examiner, Tim Rubert. RECEIVED BY DCD 12/6/2021 Window, Skylight and Door Schedule Project Information Contact Information Width Height Ref.U-factor Qt.Feet Inch Feet Inch Area UA Exempt Swinging Door (24 sq. ft. max.)0.40 1 2 6 6 8 16.7 6.67 0.40 1 2 6 5 0 12.5 5.00 Vertical Fenestration (Windows and doors) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.30 10 2 0 6 0 120.0 36.00 0.30 1 2 6 5 0 12.5 3.75 0.30 2 3 6 4 4 30.3 9.10 0.30 10 1 3 1 3 15.6 4.69 0.30 2 2 0.3 2 0.3 8.2 2.45 0.30 2 1 9 1 9 6.1 1.84 0.30 1 4 0 8 0 32.0 9.60 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Energy Refuge Chapel Quadra Engineering_Harold Andersen P.E. 2275 Duckabush Rd. Brinnon, WA 98320 (360) 379-9117 NFRC Rated Window NFRC Rated Window NFRC Rated Window NFRC Rated 1/2 round Window Top NFRC Rated 1/2 round Window Top NFRC Rated 1/2 round Window Top NFRC Rated Door Exempt Glazed Fenestration (15 sq. ft. max.) RECEIVED BY DCD 12/6/2021 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Vertical Fenestration Area and UA 224.8 67.43 Vertical Fenestration Area Weighted U = UA/Area 0.30 Overhead Glazing (Skylights) Component Width Height Description Ref.U-factor Qt.Feet Inch Feet Inch Area UA 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 0.0 0.00 Sum of Overhead Glazing Area and UA 0.0 0.00 Overhead Glazing Area Weighted U = UA/Area 0.00 253.9 79.09Total Sum of Fenestration Area and UA (for heating system sizing calculations) RECEIVED BY DCD 12/6/2021 Simple Heating System Size: Washington State Project Information Contact Information Heating System Type: To see detailed instructions for each section, place your cursor on the word "Instructions" Design Temperature Instructions Design Temperature Difference (∆T)47 ∆T = Indoor (70 degrees) - Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area (sq ft)817 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height (ft)13.2 10,784 Glazing and Doors U-Factor X Area =UA Instructions 0.300 254 76.17 Skylights U-Factor X Area =UA Instructions 0.50 --- Insulation Attic U-Factor X Area =UA Instructions 0.026 49 1.27 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions 0.027 922 24.88 Above Grade Walls (see Figure 1)U-Factor X Area UA Instructions 0.056 1,198 67.09 Floors U-Factor X Area UA Instructions No selection --- Below Grade Walls (see Figure 1)U-Factor X Area UA Instructions No selection --- Slab Below Grade (see Figure 1)F-Factor X Length UA Instructions No selection --- Slab on Grade (see Figure 1)F-Factor X Length UA Instructions 0.360 126 45.36 Location of Ducts Instructions Duct Leakage Coefficient 1.00 Sum of UA 214.78 Envelope Heat Load 10,095 Btu / Hour Sum of UA x ∆T Air Leakage Heat Load 5,474 Btu / Hour Volume x 0.6 x ∆T x 0.018 Building Design Heat Load 15,569 Btu / Hour Air leakage + envelope heat loss Building and Duct Heat Load 15,569 Btu / Hour Ducts in unconditioned space: sum of building heat loss x 1.10 Ducts in conditioned space: sum of building heat loss x 1 Maximum Heat Equipment Output 19,461 Btu / Hour Building and duct heat loss x 1.40 for forced air furnace Building and duct heat loss x 1.25 for heat pump This heating system sizing calculator is based on the Prescriptive Requirements of the 2018 Washington State Energy Code (WSEC) and ACCA Manuals J and S. This tool will calculate heating loads only. ACCA procedures for sizing cooling systems should be used to determine cooling loads. Please complete the green drop-downs and boxes that are applicable to your project. As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options, please contact the WSU Energy Program at energycode@energy.wsu.edu or (360) 956-2042 for assistance. Energy Refuge Chapel 2275 Duckabush Rd. Brinnon, WA 98320 Quadra Engineering_Harold Andersen P.E. (360) 379-9117 Above Grade Below Grade Figure 1. All Other Systems Heat Pump (07/01/13) RECEIVED BY DCD 12/6/2021