Loading...
HomeMy WebLinkAboutBLD2022-00295-07- Building PlansSHEET NUMBER: REVISION: G-001 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 TITLE SHEET LOCATIONMAPVICINITYMAP COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION UTILITY COMPANIES SHEET INDEX SHEET NO:DESCRIPTION: REV: DATE: BY: G-001 TITLE SHEET 0 08/30/21 DEX G-002 GENERAL NOTES 0 08/30/21 DEX C-101 DETAILED SITE PLAN 0 08/30/21 DEX C-201 TOWER ELEVATION 0 08/30/21 DEX C-401 ANTENNA INFORMATION & SCHEDULE 0 08/30/21 DEX C-501 CONSTRUCTIONDETAILS 0 08/30/21 DEX E-501 GROUNDINGDETAILS 0 08/30/21 DEX R-601 SUPPLEMENTAL R-602 SUPPLEMENTAL R-603 SUPPLEMENTAL POWER COMPANY: PSE PHONE: (888) 225-5773 TELEPHONE COMPANY: QWEST PHONE: (800) 603-6000 ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED IN ACCORDANCE WITH THECURRENTEDITIONS OFTHE FOLLOWING CODES ASADOPTEDBYTHE LOCAL GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO THESE CODES. 1. 2018 INTERNATIONAL BUILDING CODE (IBC) 2. 2017 NATIONAL ELECTRIC CODE (NEC) 3. LOCAL BUILDINGCODE 4. CITY/COUNTYORDINANCES SITE LOCATION VERIZON ANTENNA AMENDMENT DRAWINGS PROJECT TEAM APPLICANT: VERIZON WIRELESS TOWER OWNER: AMERICAN TOWER 10 PRESIDENTIAL WAY WOBURN, MA01801 ENGINEER: ATC TOWER SERVICES, LLC 3500 REGENCY PKWY STE 100 CARY, NC 27518 SITE ADDRESS: 1696 STARRT 104 QUILCENE, WA 98376 COUNTY: JEFFERSON GEOGRAPHIC COORDINATES: LATITUDE: 47.92132498 LONGITUDE: -122.8586181 GROUND ELEVATION: 713' AMSL TARBOO LAKE RD PROJECT NOTES THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED AND TOWERMOUNTED EQUIPMENT AS INDICATEDPERBELOW: TOWER WORK: REMOVE (6) COAX CABLE(S) INSTALL (9) ANTENNA(S), (6) RRH(S), (1) OVP, AND (1) HYBRID CABLE EXISTING (6) ANTENNA(S) TO REMAIN GROUND WORK: INSTALL (1) OVP 1. THE FACILITY IS UNMANNED. 2. ATECHNICIAN WILL VISITTHE SITEAPPROXIMATELYONCEA MONTH FOR ROUTINE INSPECTION AND MAINTENANCE. 3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE. 4. NOSANITARYSEWER, POTABLEWATER ORTRASHDISPOSAL IS REQUIRED. 5. HANDICAP ACCESS IS NOT REQUIRED. 6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED REVIEWUNDER 47U.S.C. § 1455(A) AS A MODIFICATIONOF AN EXISTING WIRELESS TOWER THAT INVOLVES THE COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL CHANGE UNDER CFR § 1.61000 (B)(7). PROJECT LOCATION DIRECTIONS CROSS HOODCANAL BRIDGE ON SR104 HEADING TOWARDS GARDINER. TAKE THE EXIT FOR CHIMACUM CENTER RD. EXIT IS JUST WEST OF SANDY SHORE RD. TURN RIGHT ONTO CENTER RD AND GO UNDER SR104. HEAD SOUTH AND TURN RIGHT ONTO TARBOO LAKE RD. FOLLOWTHE GRAVEL ROAD TO TARBOO LAKE. JUST BEFORE YOU DRIVE INTO THE PARKING LOT FOR THE LAKE YOU WILL HAVE TO TAKE A 90 DEGREE RIGHT. INSTEAD OF TURNING RIGHT AT THE 90 DEGREE BEND GO STRAIGHT THRU AN ORANGE GATE. SITE WILL BE JUST BEFORE THE POWERLINEROAD. PROPERTY OWNER: N/A 1696 STAT RT 104 QUILCENE, WA 98376 ATC SITE NAME: GARDINER #2 (WA) ATC SITE NUMBER: 82962 VERIZON SITE NAME: GARDINER VERIZON SITE NUMBER:113079 SITE ADDRESS: 1696 STAR RT 104 QUILCENE, WA 98376 PROJ# 16482284 SEAL: SHEET NUMBER: REVISION: G-002 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 GENERAL NOTES GENERAL CONSTRUCTION NOTES: 1. OWNERFURNISHED MATERIALS, VERIZON "THECOMPANY" WILLPROVIDEAND THE CONTRACTOR WILL INSTALL A. BTSEQUIPMENTFRAME (PLATFORM) ANDICEBRIDGE SHELTER (GROUND BUILD/CO-LOCATE ONLY) B. AC/TELCO INTERFACE BOX (PPC) C. ICE BRIDGE (CABLE TRAYWITHCOVER) (GROUNDBUILD/CO-LOCATE ONLY, GC TOFURNISH ANDINSTALLFORROOFTOPINSTALLATION) D. TOWERS, MONOPOLES E. TOWER LIGHTING F. GENERATORS & LIQUID PROPANE TANK G. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING H. ANTENNAS (INSTALLEDBY OTHERS) I. TRANSMISSIONLINE J. TRANSMISSIONLINEJUMPERS K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS L. TRANSMISSION LINE GROUND KITS M. HANGERS N. HOISTINGGRIPS O. BTSEQUIPMENT 2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH MATERIALSASFENCING, STRUCTURALSTEEL SUPPORTINGSUB-FRAME FOR PLATFORM, ROOFINGLABORANDMATERIALS, GROUNDINGRINGS, GROUNDINGWIRES, COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER, CONDUIT, LANDSCAPINGCOMPOUNDSTONE, CRANES, COREDRILLING, SLEEPERS AND RUBBER MATTING, REBAR, CONCRETECAISSONS, PADSAND/ORAUGERMOUNTS, MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO THEDRAWINGS ANDSPECIFICATIONS. IT ISTHEPOSITIONOFVERIZON TOAPPLYFOR PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED PERMITS. 3. ALLWORKSHALLCONFORM TOALLCURRENTAPPLICABLE FEDERAL, STATE, AND LOCAL CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION SPECIFICATIONS. 4. CONTRACTOR SHALLCONTACTLOCAL 811FOR IDENTIFICATION OFUNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. 5. CONTRACTOR SHALLBE RESPONSIBLEFORCOORDINATINGALLREQUIRED INSPECTIONS. 6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND SITEIMPROVEMENTS SHALLBEVERIFIED INFIELDBYCONTRACTOR WITHALL DISCREPANCIESREPORTEDTO THEENGINEER. 7. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS. 8. DETAILSSHOWNARETYPICAL; SIMILAR DETAILS APPLYTOSIMILAR CONDITIONSUNLESS OTHERWISE NOTED. 9. THESEDRAWINGSDONOT INCLUDE NECESSARYCOMPONENTSFOR CONSTRUCTION SAFETY WHICHSHALLBETHE SOLERESPONSIBILITYOF THECONTRACTOR. 10. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED FORSTABILITYAREINSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING, ANCHORBOLTS, ETC. 11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCINGWORK. 12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE VERIZON REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL REQUIREWRITTENAPPROVALBY THEVERIZON REP PRIORTO PROCEEDING. 13. EACH CONTRACTOR SHALL COOPERATE WITH THE VERIZON REP, AND COORDINATE HIS WORK WITHTHEWORKOF OTHERS. 14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTION OFTHEVERIZON CONSTRUCTION MANAGER. 15. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING INSTALLATION USING A SILICONE SEALANT. 16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET, CONTRACTOR SHALL NOTIFY THE VERIZON REP AND ENGINEER OF RECORD IMMEDIATELY. 17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE AND CURRENTSETOFDRAWINGS AND SPECIFICATIONSFORTHISPROJECT. 18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF EACH DAY. 19. CONTRACTOR SHALLCOORDINATE WORKSCHEDULEWITHAMERICANTOWER CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF OTHER OCCUPANTS OF THE FACILITY. 20. CONTRACTOR SHALL FURNISH VERIZON AND AMERICAN TOWER CORPORATION (ATC) WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK. 21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH VERIZON REP TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL ALL ITEMS PROVIDED. 22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH VERIZON REP TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED PERMITS NOTOBTAINEDBYVERIZON MUST BEOBTAINED, ANDPAID FOR, BYTHE CONTRACTOR. 23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH VERIZON SPECIFICATIONS ANDREQUIREMENTS. 24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO VERIZON FOR REVIEW AND APPROVAL PRIOR TO FABRICATION. 25. ALL EQUIPMENTSHALLBEINSTALLED ACCORDINGTO MANUFACTURER'S SPECIFICATIONS AND LOCATED ACCORDING TO VERIZON SPECIFICATIONS, AND AS SHOWN IN THESE PLANS. 26. THE CONTRACTORSHALL SUPERVISEAND DIRECTTHEPROJECT DESCRIBEDHEREIN. THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR COORDINATINGALLPORTIONS OFTHE WORKUNDER THECONTRACT. 27. CONTRACTOR SHALL NOTIFY VERIZON REP AMINIMUM OF 48 HOURS IN ADVANCE OF POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR SEALINGANYWALL, FLOORORROOFPENETRATIONSFOR ENGINEERING REVIEWAND APPROVAL. 28. CONTRACTORSHALLBERESPONSIBLE FORSITE SAFETY INCLUDINGCOMPLIANCE WITH ALL APPLICABLEOSHASTANDARDSANDRECOMMENDATIONS ANDSHALLPROVIDE ALL NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING, TRENCH BOXES/SLOPING, BARRIERS, ETC. 29. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY DAMAGECAUSEDBYNEGLECT ONTHEPART OFTHISCONTRACTORORHIS REPRESENTATIVES, ORBYTHE ELEMENTS DUETONEGLECTONTHE PARTOFTHIS CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS EXPENSETOTHEOWNER'SSATISFACTION. 30. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP SHALLBE SUBJECTTOTHEAPPROVALOFTHE VERIZON REP. ANYWORKFOUNDBY THE VERIZON REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS OBTAINED. 31. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF ASSPECIFIED. 32. VERIZON FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE VERIZON WAREHOUSE, NOLATER THAN48HRAFTERBEINGNOTIFIEDINSURED, STORED, UNCRATE, PROTECTED ANDINSTALLEDBY THECONTRACTOR WITHALLAPPURTENANCESREQUIRED TOPLACE THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP. 33. VERIZONORHISARCHITECT/ENGINEER RESERVESTHE RIGHTTO REJECTANY EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE EQUIPMENT SHALLBEREPLACEDWITH EQUIPMENT CONFORMINGTOTHE REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO VERIZON OR THEIR ARCHITECT/ENGINEER. SPECIAL CONSTRUCTION ANTENNA INSTALLATION NOTES: 1. WORK INCLUDED: A. ANTENNA AND COAXIAL CABLES ARE FURNISHED BY VERIZON UNDER A SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA INSTALLATIONCONTRACTOR INTERMSODCOORDINATIONANDSITEACCESS. ERECTIONSUBCONTRACTORSHALLBERESPONSIBLEFOR THEPROTECTIONOF PERSONNEL AND EQUIPMENT. B. INSTALLANTENNAASINDICATE ONDRAWINGSAND VERIZON SPECIFICATIONS. C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS D. INSTALL FURNISHED GALVANIZEDSTEELORALUMINUM WAVEGUIDE. E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY DOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER. SWEEP TESTSSHALLBEAS PERATTACHEDRFS "MINIMUMFIELDTESTING RECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED 10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE ANDBEBOUNDANDSUBMITTEDWITHINONEWEEK OFWORK COMPLETION. F. INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL CONNECTIONS BETWEENTHEANTENNAANDEQUIPMENT PER MANUFACTURER'S REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF ENTRY PORT LOCATION UNLESS OTHERWISE STATED. G. ANTENNA AND COAXIAL CABLE GROUNDING: 2. ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR EQUAL. 3. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF COAXIALCABLE (NOT WITHINBENDS) ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE CONSTRUCTION DRAWINGS SHALL BECOMMUNICATED TO ATC ENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN. FAILURE TO COMMUNICATE DIRECTLY WITHATC ENGINEERING OR ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR APPROVAL FROM ATC ENGINEERING SHALLBE THE SOLE RESPONSIBILITY OF THE GENERAL CONTRACTOR. SEAL: X X X X X X X X X X X X X X X XXXXXXX X X X X X X X X XXXXX X X X X X X X X X X X X X X X X SHEET NUMBER: REVISION: C-101 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 DETAILED SITEPLAN1DETAILEDSITEPLAN SITE PLAN NOTES: 1. THIS SITE PLAN REPRESENTS THEBEST PRESENTKNOWLEDGEAVAILABLETO THE ENGINEER ATTHE TIMEOF THIS DESIGN. THE CONTRACTOR SHALLVISIT THESITE PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT. 2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL PROPOSED AND EXISTING EQUIPMENTAND STRUCTURES DEPICTEDONTHISPLAN. BEFORE UTILIZING EXISTING CABLESUPPORTS, COAXPORTS, INSTALLING NEW PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS. 3. THIS PROJECT INCLUDES NO INSTALL OR MODIFICATION AT GRADE. LEGEND AUTOMATIC TRANSFERSWITCHATS DISCONNECTD ELECTRICALE FIBERF BOLLARDB GENERATORRECEPTACLEG HAND HOLE, VAULTHH, V ICEBRIDGEIB KENTROXBOXK GENERATORGEN METERM LIGHTINGCONTROLLC PULLBOXPB POWERPOLEPP TELCOT TRANSFORMERTRN X CHAINLINK FENCE GROUNDING TESTWELL CELL SITECABINETCSC PROPOSED CABLE LENGTH: 1. ESTIMATED LENGTH OF PROPOSED CABLE IS 272'. ESTIMATED LENGTH OF CABLE WAS PROVIDED BY CUSTOMER OR CALCULATEDBYADDINGTHE RAD CENTER AND THE DISTANCE FROM THE SHELTER ENTRY PLATE TO THE TOWER (ALONG THE ICE BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF 15% (OF THE TWO PREVIOUS VALUES), CDS DEFER TO GREATESTCABLE LENGTH. 2. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTING CABLESANDINACCORDANCE WITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTING CABLESUPPORTSTRUCTURESAS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEEL SNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USING PROPOSED STAINLESSSTEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG). GRAPHIC SCALE IN FEET ) 1 UNIT = 20 FEET 2010020 PROPOSED VERIZON EQUIPMENT 1) OVP 12 PROPOSED (1) 12x24 HYBRID CABLE ROUTEDPER TOWERNOTE2) REFER TO PROPOSED CABLE LENGTH NOTE ON THIS PAGE) SEAL: SHEET NUMBER: REVISION: C-201 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 TOWER ELEVATION EXISTINGVERIZON RAD CENTER @ 180' 2 PROPOSED TOWER ELEVATION SCALE: N.T.S. 2 C-401 1 EXISTING TOWER ELEVATION SCALE: N.T.S. 1 C-401 TOWERNOTE: 1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO CONFIRMWITHTHE PROJECT MANAGERTHAT THEY HAVE THE MOST RECENT VERSION OF THE STRUCTURAL ANALYSISBEFORE COMMENCING WORK. EXISTING ANDPROPOSED TOWER APPURTENANCES, MOUNTS, AND ANTENNAS ARE SHOWNBASEDON THE STRUCTURAL ANALYSIS. 2. WHERE APPLICABLE, ALL NEW ANTENNAS, EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT INACCORDANCE WITHFAA, JURISDICTION, AND/OR OTHERLOCALREQUIREMENTS. 3. ROUTE PROPOSED CABLES ALONG SAME PATH AS EXISTINGCABLES AND IN ACCORDANCEWITH STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE EXISTINGCABLE SUPPORT STRUCTURESAS PROVIDED FOR CARRIER TO ADEQUATELY SECURE CABLES, USING EITHER APPROPRIATELY SIZED STAINLESS STEELSNAP-INS OR MOUNTING HARDWARE AND BRACKETS AS SPECIFIED BY CABLE MANUFACTURER. OTHERWISE, ATTACH CABLES TO HORIZONTAL OR DIAGONAL TOWER MEMBERS USINGPROPOSED STAINLESSSTEEL ADAPTERS (DO NOT ATTACH TO TOWER LEG). 4. TOWER ELEVATIONS ARE MEASURED FROM TOP OF BASEPLATETO MATCH STRUCTURAL ANALYSIS. ELEVATIONS DO NOT REFLECT TRUE ABOVEGROUND LEVEL (A.G.L.) 5. TOWER ELEVATION DEPICTION MAY NOT REFLECT ALL EQUIPMENT INCLUDED IN STRUCTURAL ANALYSIS. REFER TO STRUCTURALANALYSIS FOR FULL TOWER LOADING. PROPOSED VERIZON EQUIPMENT 1) 12X24 HYBRID CABLE PROPOSED VERIZON EQUIPMENT 6) NHH-65C-R2B ANTENNAS 3) AIR6449 ANTENNAS 3) 4449RRHs 3) 8843 RRHS 1) OVP 12 TOP OF EXISTING ANTENNAS ELEV. 184' EXISTINGVERIZON RAD CENTER @ 180' TOPOFEXISTINGANTENNAS ELEV. 184' TOPOFEXISTINGANTENNAS ELEV. 184' SEAL: SHEET NUMBER: REVISION: C-401 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 ANTENNA INFORMATION SCHEDULE 1 EXISTING ANTENNA PLAN SCALE: N.T.S.2 FINAL ANTENNA PLAN SCALE: N.T.S. 3 EQUIPMENT SCHEDULES FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY MODEL NUMBER STATUS COAX HYBRID STATUS OVP12 ADD 12X24 HYBRIFLEX ADD EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY MODEL NUMBER STATUS COAX HYBRID STATUS CABLE LENGTHS FOR JUMPERS JUNCTION BOX TORRU: 15' RRU TOANTENNA: 10' 1. CONFIRM WITH VERIZON REP FOR APPLICABLE UPDATES/REVISIONS AND MOST RECENT RFDS FOR NSN CONFIGURATION (CONFIG). GC TO CAP ALL UNUSED PORTS. 2. CONFIRM SPACING OF PROPOSED EQUIP DOES NOT CAUSE TOWER CONFLICTS NOR IMPEDE TOWER CLIMBING PEGS. NOTES STATUS ABBREVIATIONS RMV: TOBEREMOVED TO REMAIN REL: TO BE RELOCATED ADD: TO BE ADDED FINALANTENNASCHEDULE LOCATION ANTENNA SUMMARY NON ANTENNASUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS ALPHA 180' 330° A1 A2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD A3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD A4 - BETA 180' 90° B1 B2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD B3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD B4 INTEGRATED - GAMMA 180' 210° C1 C2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD C3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD C4 INTEGRATED - EXISTING ANTENNA SCHEDULE LOCATION ANTENNA SUMMARY NONANTENNASUMMARY SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC D-TILT STATUS ADDITIONAL TOWER MOUNTED EQUIPMENT STATUS RMV RMV RMV RMV RMV RMV B1 A1 A2 A3 A4 B2 B3 B4 C4 C3 C2 C1 B1 A1 A2 A3 A4 B2 B3 B4 C4 C3 C2 C1 PROPOSED 3) AIR6449ANTENNAS 1 PER SECTOR) (TYP. 3) PROPOSED 6) NHH-65C-R2B ANTENNAS 2PER SECTOR)(TYP. 6) PROPOSED 8843 RRHs 1 PERSECTOR)(TYP.3) PROPOSED 4449 RRHs 1 PERSECTOR)(TYP.3) PROPOSED OVP BOX12 TYP.1) SEAL: SHEET NUMBER: REVISION: C-501 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 CONSTRUCTION DETAILS PROPOSED RRU (OPTION 1) MOUNT PERMANUFACTURER'SSPECS) ENSURE THAT BRACKET DOES NOT CONFLICT WITH EXISTING ORPROPOSED EQUIPMENT) 3 PROPOSED RRU MOUNTING DETAIL - TYPICAL SCALE: N.T.S. TOBEREPLACED WITH PROPOSED 2-3/8" O.D. X 96" LONG IFREQUIREDTO ACCOMMODATE PROPOSEDMOUNTINGBRACKET PROPOSED ANTENNA 1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. PROPOSED OVP MOUNT PER MANUFACTURER'S SPECS) ENSURETHAT BRACKETDOES NOT CONFLICT WITH EXISTING OR PROPOSED EQUIPMENT) PROPOSED OVPMOUNTING4SCALE: N.T.S. PROPOSED2-3/8" O.D. X 96" LONG PROPOSED ANTENNA 2 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICAL SCALE: N.T.S. SEAL: SHEET NUMBER: REVISION: E-501 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 GROUNDING DETAILS NOTES: 1. THIS DETAIL ISINTENDEDTO SHOW THEGENERALGROUNDING REQUIREMENTS. SLIGHT ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORMTHE CONSTRUCTION MANAGER OF ANY CONFLICTS. 2. SITE GROUNDINGSHALL COMPLYWITHVERIZON GROUNDING STANDARDS, LATEST EDITION, AND COMPLY WITH VERIZON GROUNDING CHECKLIST, LATEST VERSION. WHEN NATIONAL AND LOCALGROUNDING CODESARE MORESTRINGENTTHEY SHALLGOVERN. PROPOSED CONNECTOR AND WEATHERPROOFING KIT 1 TYPICAL ANTENNA GROUNDING DIAGRAM SCALE: N.T.S. PROPOSED ANTENNA PROPOSED JUMPER PROPOSED WEATHERPROOFING KIT 2 E-501 3 E-501 GROUND BAR MOUNTED NEAR/BELOWANTENNA TO BEINSTALLEDIF REQUIRED) 6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWN INSULATION ANTENNA CABLE TO CABINET (TYP.) PROPOSED CABLE GROUNDKITPROPOSED #6AWG STRANDED CU WIREWITHGREEN, 600V, THWN INSULATION TO PROPOSED RRU GROUNDLUG (TYP.) PROPOSED #6 AWG STRANDED CU WIRE WITH GREEN, 600V, THWNINSULATION TO PROPOSED OVP BOX DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT GROUND WIRE DOWN TO GROUND BAR. CONTRACTOR SHALLPROVIDEWEATHERPROOFINGKIT (ANDREWPART NUMBER 221213) ANDINSTALL/TAPE PERMANUFACTURER'SSPECIFICATIONS. 2 CABLE GROUND KIT CONNECTION DETAIL SCALE: N.T.S. TO ANTENNA TO EQUIPMENT TO GROUND BAR ANTENNA CABLE 2 1/2"Ø MAX GROUNDING KIT PER CABLE MANUFACTURER'S RECOMMENDATIONS ANDREW OR APPROVED EQUAL) 6AWGSTRANDEDCOPPER GROUND WIRE (GROUNDED TO GROUND BAR) GROUND KITNOTES: 1. 2. 1/4" X4" X 6" GROUND BAR ERICO P/N: EGBA14406CC OR EQUAL) 3 TOWER GROUND BAR DETAIL SCALE: N.T.S. GROUND BAR NOTES: 1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS, WASHERS, ETC. EXCEPTTHE STRUCTURAL MOUNTING MEMBER(S). 2. GROUND BARTO BE BONDEDDIRECTLYTO TOWER. 3/8" SS LOCK WASHER EACH SIDE) TWO-HOLE LUG, TO BE USED WITH #2 AWG BCW LOWER TOWER GROUND BAR ONLY) 3/8" X 1-1/2" SS BOLT EACHSIDE) SEAL: SHEET NUMBER: REVISION: R-601 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 A PRELIM DEX 08/06/21 0 SUPPLEMENTAL MANUFACTURER: ERICSSON MODEL: AIR6449 WEIGHT: 81.6 LBS DIMENSIONS: 30.4" X 15.9" X 8.1" FREQUENCY: REFER TO RF DATA SHEET TOP FRONT SIDE 15.9 10 6 30 4 15.9 TOP MANUFACTURER: ERICSSON MODEL: RADIO 8843 (BANDS 2, 66A) RADIO 4449 (BANDS 13, 5) WEIGHT: 85 LBS DIMENSIONS: 28"Hx15"Wx10"D (MAX.) 10.0" FRONT SIDE 28 0 15.0" 10 0 15.0" 28 0 2-3/8" DIA. GALV. STEEL MOUNTING PIPE 2-3/8" DIA. GALV. STEEL MOUNTING PIPE MOUNTING BRACKET PROVIDED BY MANUFACTURER MOUNTING BRACKET PROVIDED BY MANUFACTURER DC SURGE SUPPRESSION UNIT DC SURGE SUPPRESSION UNIT MANUFACTURER: RAYCAP MODEL: RCMDC-6627-PF-48 DIMENSIONS: 29.5"x16.5"x12.6" 96 0 MANUFACTURER: COMMSCOPE MODEL: NHH-65C-R2B WEIGHT: 51.6LBS; BRACKET: 13.7 LBS DIMENSIONS: 96.0" X11.9" X7.1" FREQUENCY: REFER TO RF DATA SHEET 11.9 96 0 7.1 11.9 7. 1 TOP BOTTOM FRONT SIDE MECHANICAL DOWNTILT BRACKET RF CONNECTOR, TYP RF CONNECTOR, TYP 11.9 7. 1 1 EQUIPMENT SPECIFICATIONS SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER: REVISION: R-602 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 PRELIM DEX 08/06/21 0 SUPPLEMENTAL 1 ANTENNA AND EQUIPMENT SUMMARY SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT. SHEET NUMBER: REVISION: R-603 SEAL: DESCRIPTIONREV. DATEBY ATC TOWER SERVICES, LLC 3500 REGENCY PARKWAY SUITE 100 CARY, NC 27518 PHONE: (919) 468-0112 COA: 3408 DATE DRAWN:07/28/21 ATCJOBNO: GARDINERCUSTOMERID: 13696084_G5 113079CUSTOMER #: 82962 ATCSITE NAME: GARDINER #2 (WA) GARDINER 1696 STARRT104 QUILCENE, WA 98376 ATC SITE NUMBER: SITE ADDRESS: VERIZON SITE NAME: 4515 S. MCCLINTOCK DRIVE, SUITE 217 TEMPE, AZ 85282 C O N S U L T I N G U S A 0 100% CDs AUD 08/30/21 PRELIM DEX 08/06/21 0 SUPPLEMENTAL 1 PLUMBING DIAGRAM SCALE: N.T.S. NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED BY REQUEST OF CUSTOMER WITHOUT EDIT.