HomeMy WebLinkAboutBLD2022-00295-07- Building PlansSHEET NUMBER: REVISION:
G-001
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
TITLE SHEET
LOCATIONMAPVICINITYMAP
COMPLIANCE CODE PROJECT SUMMARY PROJECT DESCRIPTION
UTILITY COMPANIES
SHEET INDEX
SHEET
NO:DESCRIPTION: REV: DATE: BY:
G-001 TITLE SHEET 0 08/30/21 DEX
G-002 GENERAL NOTES 0 08/30/21 DEX
C-101 DETAILED SITE PLAN 0 08/30/21 DEX
C-201 TOWER ELEVATION 0 08/30/21 DEX
C-401 ANTENNA INFORMATION & SCHEDULE 0 08/30/21 DEX
C-501 CONSTRUCTIONDETAILS 0 08/30/21 DEX
E-501 GROUNDINGDETAILS 0 08/30/21 DEX
R-601 SUPPLEMENTAL
R-602 SUPPLEMENTAL
R-603 SUPPLEMENTAL
POWER COMPANY: PSE
PHONE: (888) 225-5773
TELEPHONE COMPANY: QWEST
PHONE: (800) 603-6000
ALL WORK SHALL BE PERFORMED AND MATERIALS INSTALLED
IN ACCORDANCE WITH THECURRENTEDITIONS OFTHE
FOLLOWING CODES ASADOPTEDBYTHE LOCAL
GOVERNMENT AUTHORITIES. NOTHING IN THESE PLANS IS
TO BE CONSTRUED TO PERMIT WORK NOT CONFORMING TO
THESE CODES.
1. 2018 INTERNATIONAL BUILDING CODE (IBC)
2. 2017 NATIONAL ELECTRIC CODE (NEC)
3. LOCAL BUILDINGCODE
4. CITY/COUNTYORDINANCES
SITE LOCATION
VERIZON
ANTENNA AMENDMENT DRAWINGS
PROJECT TEAM
APPLICANT:
VERIZON WIRELESS
TOWER OWNER:
AMERICAN TOWER
10 PRESIDENTIAL WAY
WOBURN, MA01801
ENGINEER:
ATC TOWER SERVICES, LLC
3500 REGENCY PKWY STE 100
CARY, NC 27518
SITE ADDRESS:
1696 STARRT 104
QUILCENE, WA 98376
COUNTY: JEFFERSON
GEOGRAPHIC COORDINATES:
LATITUDE: 47.92132498
LONGITUDE: -122.8586181
GROUND ELEVATION: 713' AMSL
TARBOO LAKE RD
PROJECT NOTES
THE PROPOSED PROJECT INCLUDES MODIFYING GROUND BASED
AND TOWERMOUNTED EQUIPMENT AS INDICATEDPERBELOW:
TOWER WORK:
REMOVE (6) COAX CABLE(S)
INSTALL (9) ANTENNA(S), (6) RRH(S), (1) OVP, AND (1) HYBRID CABLE
EXISTING (6) ANTENNA(S) TO REMAIN
GROUND WORK:
INSTALL (1) OVP
1. THE FACILITY IS UNMANNED.
2. ATECHNICIAN WILL VISITTHE SITEAPPROXIMATELYONCEA
MONTH FOR ROUTINE INSPECTION AND MAINTENANCE.
3. THE PROJECT WILL NOT RESULT IN ANY SIGNIFICANT LAND
DISTURBANCE OR EFFECT OF STORM WATER DRAINAGE.
4. NOSANITARYSEWER, POTABLEWATER ORTRASHDISPOSAL
IS REQUIRED.
5. HANDICAP ACCESS IS NOT REQUIRED.
6. THE PROJECT DEPICTED IN THESE PLANS QUALIFIES AS AN
ELIGIBLE FACILITIES REQUEST ENTITLED TO EXPEDITED
REVIEWUNDER 47U.S.C. § 1455(A) AS A MODIFICATIONOF AN
EXISTING WIRELESS TOWER THAT INVOLVES THE
COLLOCATION, REMOVAL, AND/OR REPLACEMENT OF
TRANSMISSION EQUIPMENT THAT IS NOT A SUBSTANTIAL
CHANGE UNDER CFR § 1.61000 (B)(7).
PROJECT LOCATION DIRECTIONS
CROSS HOODCANAL BRIDGE ON SR104 HEADING TOWARDS
GARDINER. TAKE THE EXIT FOR CHIMACUM CENTER RD. EXIT
IS JUST WEST OF SANDY SHORE RD. TURN RIGHT ONTO
CENTER RD AND GO UNDER SR104. HEAD SOUTH AND TURN
RIGHT ONTO TARBOO LAKE RD. FOLLOWTHE GRAVEL ROAD
TO TARBOO LAKE. JUST BEFORE YOU DRIVE INTO THE
PARKING LOT FOR THE LAKE YOU WILL HAVE TO TAKE A 90
DEGREE RIGHT. INSTEAD OF TURNING RIGHT AT THE 90
DEGREE BEND GO STRAIGHT THRU AN ORANGE GATE. SITE
WILL BE JUST BEFORE THE POWERLINEROAD.
PROPERTY OWNER:
N/A
1696 STAT RT 104
QUILCENE, WA 98376
ATC SITE NAME: GARDINER #2 (WA)
ATC SITE NUMBER: 82962
VERIZON SITE NAME: GARDINER
VERIZON SITE NUMBER:113079
SITE ADDRESS: 1696 STAR RT 104
QUILCENE, WA 98376
PROJ# 16482284
SEAL:
SHEET NUMBER: REVISION:
G-002
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
GENERAL NOTES
GENERAL CONSTRUCTION NOTES:
1. OWNERFURNISHED MATERIALS, VERIZON "THECOMPANY" WILLPROVIDEAND THE
CONTRACTOR WILL INSTALL
A. BTSEQUIPMENTFRAME (PLATFORM) ANDICEBRIDGE SHELTER (GROUND
BUILD/CO-LOCATE ONLY)
B. AC/TELCO INTERFACE BOX (PPC)
C. ICE BRIDGE (CABLE TRAYWITHCOVER) (GROUNDBUILD/CO-LOCATE ONLY, GC
TOFURNISH ANDINSTALLFORROOFTOPINSTALLATION)
D. TOWERS, MONOPOLES
E. TOWER LIGHTING
F. GENERATORS & LIQUID PROPANE TANK
G. ANTENNA STANDARD BRACKETS, FRAMES AND PIPES FOR MOUNTING
H. ANTENNAS (INSTALLEDBY OTHERS)
I. TRANSMISSIONLINE
J. TRANSMISSIONLINEJUMPERS
K. TRANSMISSION LINE CONNECTORS WITH WEATHERPROOFING KITS
L. TRANSMISSION LINE GROUND KITS
M. HANGERS
N. HOISTINGGRIPS
O. BTSEQUIPMENT
2. THE CONTRACTOR IS RESPONSIBLE TO PROVIDE ALL OTHER MATERIALS FOR THE
COMPLETE INSTALLATION OF THE SITE INCLUDING, BUT NOT LIMITED TO, SUCH
MATERIALSASFENCING, STRUCTURALSTEEL SUPPORTINGSUB-FRAME FOR PLATFORM,
ROOFINGLABORANDMATERIALS, GROUNDINGRINGS, GROUNDINGWIRES,
COPPER-CLAD OR XIT CHEMICAL GROUND ROD(S), BUSS BARS, TRANSFORMERS AND
DISCONNECT SWITCHES WHERE APPLICABLE, TEMPORARY ELECTRICAL POWER,
CONDUIT, LANDSCAPINGCOMPOUNDSTONE, CRANES, COREDRILLING, SLEEPERS AND
RUBBER MATTING, REBAR, CONCRETECAISSONS, PADSAND/ORAUGERMOUNTS,
MISCELLANEOUS FASTENERS, CABLE TRAYS, NON-STANDARD ANTENNA FRAMES AND
ALL OTHER MATERIAL AND LABOR REQUIRED TO COMPLETE THE JOB ACCORDING TO
THEDRAWINGS ANDSPECIFICATIONS. IT ISTHEPOSITIONOFVERIZON TOAPPLYFOR
PERMITTING AND CONTRACTOR RESPONSIBLE FOR PICKUP AND PAYMENT OF REQUIRED
PERMITS.
3. ALLWORKSHALLCONFORM TOALLCURRENTAPPLICABLE FEDERAL, STATE, AND LOCAL
CODES, INCLUDING ANSI/EIA/TIA-222, AND COMPLY WITH ATC CONSTRUCTION
SPECIFICATIONS.
4. CONTRACTOR SHALLCONTACTLOCAL 811FOR IDENTIFICATION OFUNDERGROUND
UTILITIES PRIOR TO START OF CONSTRUCTION.
5. CONTRACTOR SHALLBE RESPONSIBLEFORCOORDINATINGALLREQUIRED
INSPECTIONS.
6. ALL DIMENSIONS TO, OF, AND ON EXISTING BUILDINGS, DRAINAGE STRUCTURES, AND
SITEIMPROVEMENTS SHALLBEVERIFIED INFIELDBYCONTRACTOR WITHALL
DISCREPANCIESREPORTEDTO THEENGINEER.
7. DO NOT CHANGE SIZE OR SPACING OF STRUCTURAL ELEMENTS.
8. DETAILSSHOWNARETYPICAL; SIMILAR DETAILS APPLYTOSIMILAR CONDITIONSUNLESS
OTHERWISE NOTED.
9. THESEDRAWINGSDONOT INCLUDE NECESSARYCOMPONENTSFOR CONSTRUCTION
SAFETY WHICHSHALLBETHE SOLERESPONSIBILITYOF THECONTRACTOR.
10. CONTRACTOR SHALL BRACE STRUCTURES UNTIL ALL STRUCTURAL ELEMENTS NEEDED
FORSTABILITYAREINSTALLED. THESE ELEMENTS ARE AS FOLLOWS: LATERAL BRACING,
ANCHORBOLTS, ETC.
11. CONTRACTOR SHALL DETERMINE EXACT LOCATION OF EXISTING UTILITIES, GROUNDS
DRAINS, DRAIN PIPES, VENTS, ETC. BEFORE COMMENCINGWORK.
12. INCORRECTLY FABRICATED, DAMAGED, OR OTHERWISE MISFITTING OR
NONCONFORMING MATERIALS OR CONDITIONS SHALL BE REPORTED TO THE VERIZON
REP PRIOR TO REMEDIAL OR CORRECTIVE ACTION. ANY SUCH REMEDIAL ACTION SHALL
REQUIREWRITTENAPPROVALBY THEVERIZON REP PRIORTO PROCEEDING.
13. EACH CONTRACTOR SHALL COOPERATE WITH THE VERIZON REP, AND COORDINATE HIS
WORK WITHTHEWORKOF OTHERS.
14. CONTRACTOR SHALL REPAIR ANY DAMAGE CAUSED BY CONSTRUCTION OF THIS
PROJECT TO MATCH EXISTING PRE-CONSTRUCTION CONDITIONS TO THE SATISFACTION
OFTHEVERIZON CONSTRUCTION MANAGER.
15. ALL CABLE/CONDUIT ENTRY/EXIT PORTS SHALL BE WEATHERPROOFED DURING
INSTALLATION USING A SILICONE SEALANT.
16. WHERE EXISTING CONDITIONS DO NOT MATCH THOSE SHOWN IN THIS PLAN SET,
CONTRACTOR SHALL NOTIFY THE VERIZON REP AND ENGINEER OF RECORD
IMMEDIATELY.
17. CONTRACTOR SHALL ENSURE ALL SUBCONTRACTORS ARE PROVIDED WITH A COMPLETE
AND CURRENTSETOFDRAWINGS AND SPECIFICATIONSFORTHISPROJECT.
18. CONTRACTOR SHALL REMOVE ALL RUBBISH AND DEBRIS FROM THE SITE AT THE END OF
EACH DAY.
19. CONTRACTOR SHALLCOORDINATE WORKSCHEDULEWITHAMERICANTOWER
CORPORATION (ATC) AND TAKE PRECAUTIONS TO MINIMIZE IMPACT AND DISRUPTION OF
OTHER OCCUPANTS OF THE FACILITY.
20. CONTRACTOR SHALL FURNISH VERIZON AND AMERICAN TOWER CORPORATION (ATC)
WITH A PDF MARKED UP AS-BUILT SET OF DRAWINGS UPON COMPLETION OF WORK.
21. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH VERIZON REP
TO DETERMINE WHAT, IF ANY, ITEMS WILL BE PROVIDED. ALL ITEMS NOT PROVIDED
SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR. CONTRACTOR WILL INSTALL
ALL ITEMS PROVIDED.
22. PRIOR TO SUBMISSION OF BID, CONTRACTOR SHALL COORDINATE WITH VERIZON REP
TO DETERMINE IF ANY PERMITS WILL BE OBTAINED BY CONTRACTOR. ALL REQUIRED
PERMITS NOTOBTAINEDBYVERIZON MUST BEOBTAINED, ANDPAID FOR, BYTHE
CONTRACTOR.
23. CONTRACTOR SHALL INSTALL ALL SITE SIGNAGE IN ACCORDANCE WITH VERIZON
SPECIFICATIONS ANDREQUIREMENTS.
24. CONTRACTOR SHALL SUBMIT ALL SHOP DRAWINGS TO VERIZON FOR REVIEW AND
APPROVAL PRIOR TO FABRICATION.
25. ALL EQUIPMENTSHALLBEINSTALLED ACCORDINGTO MANUFACTURER'S
SPECIFICATIONS AND LOCATED ACCORDING TO VERIZON SPECIFICATIONS, AND AS
SHOWN IN THESE PLANS.
26. THE CONTRACTORSHALL SUPERVISEAND DIRECTTHEPROJECT DESCRIBEDHEREIN.
THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ALL THE CONSTRUCTION
MEANS, METHODS, TECHNIQUES, SEQUENCES AND PROCEDURES AND FOR
COORDINATINGALLPORTIONS OFTHE WORKUNDER THECONTRACT.
27. CONTRACTOR SHALL NOTIFY VERIZON REP AMINIMUM OF 48 HOURS IN ADVANCE OF
POURING CONCRETE OR BACKFILLING ANY UNDERGROUND UTILITIES, FOUNDATIONS OR
SEALINGANYWALL, FLOORORROOFPENETRATIONSFOR ENGINEERING REVIEWAND
APPROVAL.
28. CONTRACTORSHALLBERESPONSIBLE FORSITE SAFETY INCLUDINGCOMPLIANCE WITH
ALL APPLICABLEOSHASTANDARDSANDRECOMMENDATIONS ANDSHALLPROVIDE ALL
NECESSARY SAFETY DEVICES INCLUDING PPE AND PPM AND CONSTRUCTION DEVICES
SUCH AS WELDING AND FIRE PREVENTION, TEMPORARY SHORING, SCAFFOLDING,
TRENCH BOXES/SLOPING, BARRIERS, ETC.
29. THE CONTRACTOR SHALL PROTECT AT HIS OWN EXPENSE, ALL EXISTING FACILITIES AND
SUCH OF HIS NEW WORK LIABLE TO INJURY DURING THE CONSTRUCTION PERIOD. ANY
DAMAGECAUSEDBYNEGLECT ONTHEPART OFTHISCONTRACTORORHIS
REPRESENTATIVES, ORBYTHE ELEMENTS DUETONEGLECTONTHE PARTOFTHIS
CONTRACTOR OR HIS REPRESENTATIVES, EITHER TO THE EXISTING WORK, OR TO HIS
WORK OR THE WORK OF ANY OTHER CONTRACTOR, SHALL BE REPAIRED AT HIS
EXPENSETOTHEOWNER'SSATISFACTION.
30. ALL WORK SHALL BE INSTALLED IN A FIRST CLASS, NEAT AND WORKMANLIKE MANNER
BY MECHANICS SKILLED IN THE TRADE INVOLVED. THE QUALITY OF WORKMANSHIP
SHALLBE SUBJECTTOTHEAPPROVALOFTHE VERIZON REP. ANYWORKFOUNDBY
THE VERIZON REP TO BE OF INFERIOR QUALITY AND/OR WORKMANSHIP SHALL BE
REPLACED AND/OR REWORKED AT CONTRACTOR EXPENSE UNTIL APPROVAL IS
OBTAINED.
31. IN ORDER TO ESTABLISH STANDARDS OF QUALITY AND PERFORMANCE, ALL TYPES OF
ASSPECIFIED.
32. VERIZON FURNISHED EQUIPMENT SHALL BE PICKED-UP AT THE VERIZON WAREHOUSE,
NOLATER THAN48HRAFTERBEINGNOTIFIEDINSURED, STORED, UNCRATE, PROTECTED
ANDINSTALLEDBY THECONTRACTOR WITHALLAPPURTENANCESREQUIRED TOPLACE
THE EQUIPMENT IN OPERATION, READY FOR USE. THE CONTRACTOR SHALL BE
RESPONSIBLE FOR THE EQUIPMENT AFTER PICKING IT UP.
33. VERIZONORHISARCHITECT/ENGINEER RESERVESTHE RIGHTTO REJECTANY
EQUIPMENT OR MATERIALS WHICH, IN HIS OWN OPINION ARE NOT IN COMPLIANCE WITH
THE CONTRACT DOCUMENTS, EITHER BEFORE OR AFTER INSTALLATION AND THE
EQUIPMENT SHALLBEREPLACEDWITH EQUIPMENT CONFORMINGTOTHE
REQUIREMENTS OF THE CONTRACT DOCUMENTS BY THE CONTRACTOR AT NO COST TO
VERIZON OR THEIR ARCHITECT/ENGINEER.
SPECIAL CONSTRUCTION
ANTENNA INSTALLATION NOTES:
1. WORK INCLUDED:
A. ANTENNA AND COAXIAL CABLES ARE FURNISHED BY VERIZON UNDER A
SEPARATE CONTRACT. THE CONTRACTOR SHALL ASSIST ANTENNA
INSTALLATIONCONTRACTOR INTERMSODCOORDINATIONANDSITEACCESS.
ERECTIONSUBCONTRACTORSHALLBERESPONSIBLEFOR THEPROTECTIONOF
PERSONNEL AND EQUIPMENT.
B. INSTALLANTENNAASINDICATE ONDRAWINGSAND VERIZON SPECIFICATIONS.
C. INSTALL GALVANIZED STEEL ANTENNA MOUNTS AS INDICATED ON DRAWINGS
D. INSTALL FURNISHED GALVANIZEDSTEELORALUMINUM WAVEGUIDE.
E. CONTRACTOR SHALL PROVIDE FOUR (4) SETS OF SWEEP TESTS USING
ANRITZU-PACKARD 8713B RF SCALAR NETWORK ANALYZER. SUBMIT FREQUENCY
DOMAIN REFLECTOMETER(FDR) TESTS RESULTS TO THE PROJECT MANAGER.
SWEEP TESTSSHALLBEAS PERATTACHEDRFS "MINIMUMFIELDTESTING
RECOMMENDED FOR ANTENNA AND HELIAX COAXIAL CABLE SYSTEMS" DATED
10/5/93. TESTING SHALL BE PERFORMED BY AN INDEPENDENT TESTING SERVICE
ANDBEBOUNDANDSUBMITTEDWITHINONEWEEK OFWORK COMPLETION.
F. INSTALL COAXIAL CABLES AND TERMINATING BETWEEN ANTENNAS AND
EQUIPMENT PER MANUFACTURER'S RECOMMENDATIONS. WEATHERPROOF ALL
CONNECTIONS BETWEENTHEANTENNAANDEQUIPMENT PER MANUFACTURER'S
REQUIREMENTS. TERMINATE ALL COAXIAL CABLE THREE (3) FEET IN EXCESS OF
ENTRY PORT LOCATION UNLESS OTHERWISE STATED.
G. ANTENNA AND COAXIAL CABLE GROUNDING:
2. ALL EXTERIOR #6 GREED GROUND WIRE "DAISY CHAIN" CONNECTIONS ARE TO BE
WEATHER SEALED WITH RFS CONNECTORS/SPLICE WEATHERPROOFING KIT #221213 OR
EQUAL.
3. ALL COAXIAL CABLE GROUNDING KITS ARE TO BE INSTALLED ON STRAIGHT RUNS OF
COAXIALCABLE (NOT WITHINBENDS)
ALL DISCREPANCIES FROM WHAT IS SHOWN ON THESE
CONSTRUCTION DRAWINGS SHALL BECOMMUNICATED TO ATC
ENGINEERING IMMEDIATELY FOR CORRECTION OR RE-DESIGN.
FAILURE TO COMMUNICATE DIRECTLY WITHATC ENGINEERING OR
ANY CHANGES FROM THE DESIGN CONDUCTED WITHOUT PRIOR
APPROVAL FROM ATC ENGINEERING SHALLBE THE SOLE
RESPONSIBILITY OF THE GENERAL CONTRACTOR.
SEAL:
X
X
X
X
X
X
X X X X X X
X X X XXXXXXX
X
X
X
X
X
X
X
X XXXXX
X
X
X
X
X
X
X
X
X
X
X
X X X X X
SHEET NUMBER: REVISION:
C-101
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
DETAILED SITEPLAN1DETAILEDSITEPLAN
SITE PLAN NOTES:
1. THIS SITE PLAN REPRESENTS THEBEST PRESENTKNOWLEDGEAVAILABLETO THE ENGINEER ATTHE TIMEOF THIS DESIGN. THE CONTRACTOR SHALLVISIT THESITE
PRIOR TO CONSTRUCTION AND VERIFY ALL EXISTING CONDITIONS RELATED TO THE SCOPE OF WORK FOR THIS PROJECT.
2. ICE BRIDGE, CABLE LADDER, COAX PORT, AND COAX CABLE ARE SHOWN FOR REFERENCE ONLY. CONTRACTOR SHALL CONFIRM THE EXACT LOCATION OF ALL
PROPOSED AND EXISTING EQUIPMENTAND STRUCTURES DEPICTEDONTHISPLAN. BEFORE UTILIZING EXISTING CABLESUPPORTS, COAXPORTS, INSTALLING NEW
PORTS OR ANY OTHER EQUIPMENT, CONTRACTOR SHALL VERIFY ALL ASPECTS OF THE COMPONENTS MEET THE ATC SPECIFICATIONS.
3. THIS PROJECT INCLUDES NO INSTALL OR MODIFICATION AT GRADE.
LEGEND
AUTOMATIC TRANSFERSWITCHATS
DISCONNECTD
ELECTRICALE
FIBERF
BOLLARDB
GENERATORRECEPTACLEG
HAND HOLE, VAULTHH, V
ICEBRIDGEIB
KENTROXBOXK
GENERATORGEN
METERM
LIGHTINGCONTROLLC
PULLBOXPB
POWERPOLEPP
TELCOT
TRANSFORMERTRN
X CHAINLINK FENCE
GROUNDING TESTWELL
CELL SITECABINETCSC
PROPOSED CABLE LENGTH:
1. ESTIMATED LENGTH OF PROPOSED CABLE IS 272'.
ESTIMATED LENGTH OF CABLE WAS PROVIDED BY
CUSTOMER OR CALCULATEDBYADDINGTHE RAD
CENTER AND THE DISTANCE FROM THE SHELTER
ENTRY PLATE TO THE TOWER (ALONG THE ICE
BRIDGE) AND A SAFETY FACTOR MEASUREMENT OF
15% (OF THE TWO PREVIOUS VALUES), CDS DEFER
TO GREATESTCABLE LENGTH.
2. ROUTE PROPOSED CABLES ALONG SAME PATH AS
EXISTING CABLESANDINACCORDANCE WITH
STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE
EXISTING CABLESUPPORTSTRUCTURESAS
PROVIDED FOR CARRIER TO ADEQUATELY SECURE
CABLES, USING EITHER APPROPRIATELY SIZED
STAINLESS STEEL SNAP-INS OR MOUNTING
HARDWARE AND BRACKETS AS SPECIFIED BY CABLE
MANUFACTURER. OTHERWISE, ATTACH CABLES TO
HORIZONTAL OR DIAGONAL TOWER MEMBERS
USING PROPOSED STAINLESSSTEEL ADAPTERS (DO
NOT ATTACH TO TOWER LEG).
GRAPHIC SCALE
IN FEET )
1 UNIT = 20 FEET
2010020
PROPOSED VERIZON EQUIPMENT
1) OVP 12
PROPOSED (1) 12x24 HYBRID CABLE
ROUTEDPER TOWERNOTE2)
REFER TO PROPOSED CABLE
LENGTH NOTE ON THIS PAGE)
SEAL:
SHEET NUMBER: REVISION:
C-201
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
TOWER ELEVATION
EXISTINGVERIZON
RAD CENTER @ 180'
2 PROPOSED TOWER ELEVATION
SCALE: N.T.S.
2
C-401
1 EXISTING TOWER ELEVATION
SCALE: N.T.S.
1
C-401
TOWERNOTE:
1. IT IS THE CONTRACTOR'S RESPONSIBILITY TO
CONFIRMWITHTHE PROJECT MANAGERTHAT
THEY HAVE THE MOST RECENT VERSION OF THE
STRUCTURAL ANALYSISBEFORE COMMENCING
WORK. EXISTING ANDPROPOSED TOWER
APPURTENANCES, MOUNTS, AND ANTENNAS ARE
SHOWNBASEDON THE STRUCTURAL ANALYSIS.
2. WHERE APPLICABLE, ALL NEW ANTENNAS,
EQUIPMENT, MOUNTS, CABLING, ETC. SHALL BE
PAINTED/SOCKED TO MATCH EXISTING EQUIPMENT
INACCORDANCE WITHFAA, JURISDICTION, AND/OR
OTHERLOCALREQUIREMENTS.
3. ROUTE PROPOSED CABLES ALONG SAME PATH AS
EXISTINGCABLES AND IN ACCORDANCEWITH
STRUCTURAL ANALYSIS. WHERE POSSIBLE UTILIZE
EXISTINGCABLE SUPPORT STRUCTURESAS
PROVIDED FOR CARRIER TO ADEQUATELY SECURE
CABLES, USING EITHER APPROPRIATELY SIZED
STAINLESS STEELSNAP-INS OR MOUNTING
HARDWARE AND BRACKETS AS SPECIFIED BY
CABLE MANUFACTURER. OTHERWISE, ATTACH
CABLES TO HORIZONTAL OR DIAGONAL TOWER
MEMBERS USINGPROPOSED STAINLESSSTEEL
ADAPTERS (DO NOT ATTACH TO TOWER LEG).
4. TOWER ELEVATIONS ARE MEASURED FROM TOP
OF BASEPLATETO MATCH STRUCTURAL
ANALYSIS. ELEVATIONS DO NOT REFLECT TRUE
ABOVEGROUND LEVEL (A.G.L.)
5. TOWER ELEVATION DEPICTION MAY NOT REFLECT
ALL EQUIPMENT INCLUDED IN STRUCTURAL
ANALYSIS. REFER TO STRUCTURALANALYSIS FOR
FULL TOWER LOADING.
PROPOSED VERIZON EQUIPMENT
1) 12X24 HYBRID CABLE
PROPOSED VERIZON EQUIPMENT
6) NHH-65C-R2B ANTENNAS
3) AIR6449 ANTENNAS
3) 4449RRHs
3) 8843 RRHS
1) OVP 12
TOP OF EXISTING ANTENNAS
ELEV. 184'
EXISTINGVERIZON
RAD CENTER @ 180'
TOPOFEXISTINGANTENNAS
ELEV. 184'
TOPOFEXISTINGANTENNAS
ELEV. 184'
SEAL:
SHEET NUMBER: REVISION:
C-401
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
ANTENNA INFORMATION
SCHEDULE
1 EXISTING ANTENNA PLAN
SCALE: N.T.S.2 FINAL ANTENNA PLAN
SCALE: N.T.S.
3 EQUIPMENT SCHEDULES
FINAL FIBER DISTRIBUTION / OVP BOX FINAL CABLING SUMMARY
MODEL NUMBER STATUS COAX HYBRID STATUS
OVP12 ADD
12X24 HYBRIFLEX ADD
EXISTING FIBER DISTRIBUTION/OVP BOX EXISTING CABLING SUMMARY
MODEL NUMBER STATUS COAX HYBRID STATUS
CABLE LENGTHS FOR JUMPERS
JUNCTION BOX TORRU: 15'
RRU TOANTENNA: 10'
1. CONFIRM WITH VERIZON REP
FOR APPLICABLE
UPDATES/REVISIONS AND
MOST RECENT RFDS FOR NSN
CONFIGURATION (CONFIG). GC
TO CAP ALL UNUSED PORTS.
2. CONFIRM SPACING OF
PROPOSED EQUIP DOES NOT
CAUSE TOWER CONFLICTS
NOR IMPEDE TOWER CLIMBING
PEGS.
NOTES
STATUS ABBREVIATIONS
RMV: TOBEREMOVED
TO REMAIN
REL: TO BE RELOCATED
ADD: TO BE ADDED
FINALANTENNASCHEDULE
LOCATION ANTENNA SUMMARY NON ANTENNASUMMARY
SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC
D-TILT STATUS ADDITIONAL TOWER
MOUNTED EQUIPMENT STATUS
ALPHA 180' 330°
A1
A2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD
A3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD
A4 -
BETA 180' 90°
B1
B2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD
B3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD
B4 INTEGRATED -
GAMMA 180' 210°
C1
C2 (2) NHH-65C-R2B LTE 1/2 ADD 4449 ADD
C3 ERICSSON AIR6449 5G 0/6 ADD 8843 ADD
C4 INTEGRATED -
EXISTING ANTENNA SCHEDULE
LOCATION ANTENNA SUMMARY NONANTENNASUMMARY
SECTOR RAD AZ POS ANTENNA BAND MECH/ELEC
D-TILT STATUS ADDITIONAL TOWER
MOUNTED EQUIPMENT STATUS
RMV
RMV
RMV
RMV
RMV
RMV
B1
A1
A2
A3
A4
B2
B3
B4
C4
C3
C2
C1
B1
A1
A2
A3
A4
B2
B3
B4
C4
C3
C2
C1
PROPOSED
3) AIR6449ANTENNAS
1 PER SECTOR) (TYP. 3)
PROPOSED
6) NHH-65C-R2B ANTENNAS
2PER SECTOR)(TYP. 6)
PROPOSED
8843 RRHs
1 PERSECTOR)(TYP.3)
PROPOSED
4449 RRHs
1 PERSECTOR)(TYP.3)
PROPOSED
OVP BOX12
TYP.1)
SEAL:
SHEET NUMBER: REVISION:
C-501
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
CONSTRUCTION
DETAILS
PROPOSED RRU (OPTION 1)
MOUNT PERMANUFACTURER'SSPECS)
ENSURE THAT BRACKET DOES NOT CONFLICT WITH
EXISTING ORPROPOSED EQUIPMENT)
3 PROPOSED RRU MOUNTING DETAIL - TYPICAL
SCALE: N.T.S.
TOBEREPLACED WITH PROPOSED 2-3/8" O.D. X 96" LONG
IFREQUIREDTO ACCOMMODATE PROPOSEDMOUNTINGBRACKET
PROPOSED ANTENNA
1 PROPOSED ANTENNA MOUNTING DETAIL - TYPICAL
SCALE: N.T.S.
PROPOSED OVP
MOUNT PER MANUFACTURER'S SPECS)
ENSURETHAT BRACKETDOES NOT CONFLICT
WITH EXISTING OR PROPOSED EQUIPMENT)
PROPOSED OVPMOUNTING4SCALE: N.T.S.
PROPOSED2-3/8" O.D. X 96" LONG
PROPOSED ANTENNA
2 PROPOSED 5G ANTENNA MOUNTING DETAIL - TYPICAL
SCALE: N.T.S.
SEAL:
SHEET NUMBER: REVISION:
E-501
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
GROUNDING DETAILS
NOTES:
1. THIS DETAIL ISINTENDEDTO SHOW THEGENERALGROUNDING REQUIREMENTS. SLIGHT
ADJUSTMENTS MAY BE REQUIRED BASED ON EXISTING SITE CONDITIONS. THE
CONTRACTOR SHALL MAKE FIELD ADJUSTMENTS AS NEEDED AND INFORMTHE
CONSTRUCTION MANAGER OF ANY CONFLICTS.
2. SITE GROUNDINGSHALL COMPLYWITHVERIZON GROUNDING STANDARDS, LATEST
EDITION, AND COMPLY WITH VERIZON GROUNDING CHECKLIST, LATEST VERSION. WHEN
NATIONAL AND LOCALGROUNDING CODESARE MORESTRINGENTTHEY SHALLGOVERN.
PROPOSED CONNECTOR AND
WEATHERPROOFING KIT
1 TYPICAL ANTENNA GROUNDING DIAGRAM
SCALE: N.T.S.
PROPOSED ANTENNA
PROPOSED JUMPER
PROPOSED WEATHERPROOFING KIT
2
E-501
3
E-501
GROUND BAR MOUNTED
NEAR/BELOWANTENNA
TO BEINSTALLEDIF
REQUIRED)
6 AWG STRANDED CU
WIRE WITH GREEN, 600V,
THWN INSULATION
ANTENNA CABLE TO
CABINET (TYP.)
PROPOSED CABLE
GROUNDKITPROPOSED #6AWG
STRANDED CU
WIREWITHGREEN, 600V,
THWN INSULATION
TO PROPOSED RRU
GROUNDLUG (TYP.)
PROPOSED #6 AWG
STRANDED CU
WIRE WITH GREEN, 600V,
THWNINSULATION
TO PROPOSED OVP BOX
DO NOT INSTALL CABLE GROUND KIT AT A BEND AND ALWAYS DIRECT
GROUND WIRE DOWN TO GROUND BAR.
CONTRACTOR SHALLPROVIDEWEATHERPROOFINGKIT (ANDREWPART
NUMBER 221213) ANDINSTALL/TAPE PERMANUFACTURER'SSPECIFICATIONS.
2 CABLE GROUND KIT CONNECTION DETAIL
SCALE: N.T.S.
TO ANTENNA
TO EQUIPMENT
TO GROUND BAR
ANTENNA CABLE 2 1/2"Ø MAX
GROUNDING KIT PER CABLE
MANUFACTURER'S RECOMMENDATIONS
ANDREW OR APPROVED EQUAL)
6AWGSTRANDEDCOPPER GROUND
WIRE (GROUNDED TO GROUND BAR)
GROUND KITNOTES:
1.
2.
1/4" X4" X 6" GROUND BAR
ERICO P/N: EGBA14406CC OR EQUAL)
3 TOWER GROUND BAR DETAIL
SCALE: N.T.S.
GROUND BAR NOTES:
1. GROUND BAR KITS COME WITH ALL HARDWARE, NUTS, BOLTS,
WASHERS, ETC. EXCEPTTHE STRUCTURAL MOUNTING MEMBER(S).
2. GROUND BARTO BE BONDEDDIRECTLYTO TOWER.
3/8" SS LOCK WASHER
EACH SIDE)
TWO-HOLE LUG, TO BE USED
WITH #2 AWG BCW
LOWER TOWER GROUND
BAR ONLY)
3/8" X 1-1/2" SS BOLT
EACHSIDE)
SEAL:
SHEET NUMBER: REVISION:
R-601
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
A PRELIM DEX 08/06/21
0
SUPPLEMENTAL
MANUFACTURER: ERICSSON
MODEL: AIR6449
WEIGHT: 81.6 LBS
DIMENSIONS: 30.4" X 15.9" X 8.1"
FREQUENCY: REFER TO RF DATA SHEET
TOP
FRONT SIDE
15.9
10
6
30
4
15.9
TOP
MANUFACTURER: ERICSSON
MODEL: RADIO 8843 (BANDS 2, 66A)
RADIO 4449 (BANDS 13, 5)
WEIGHT: 85 LBS
DIMENSIONS: 28"Hx15"Wx10"D (MAX.)
10.0"
FRONT SIDE
28
0
15.0"
10
0
15.0"
28
0
2-3/8" DIA. GALV. STEEL
MOUNTING PIPE
2-3/8" DIA. GALV. STEEL
MOUNTING PIPE
MOUNTING BRACKET
PROVIDED BY
MANUFACTURER
MOUNTING BRACKET
PROVIDED BY
MANUFACTURER
DC SURGE
SUPPRESSION UNIT
DC SURGE
SUPPRESSION UNIT
MANUFACTURER: RAYCAP
MODEL: RCMDC-6627-PF-48
DIMENSIONS: 29.5"x16.5"x12.6"
96
0
MANUFACTURER: COMMSCOPE
MODEL: NHH-65C-R2B
WEIGHT: 51.6LBS; BRACKET: 13.7 LBS
DIMENSIONS: 96.0" X11.9" X7.1"
FREQUENCY: REFER TO RF DATA SHEET
11.9
96
0
7.1
11.9
7.
1
TOP
BOTTOM
FRONT SIDE
MECHANICAL
DOWNTILT
BRACKET
RF CONNECTOR, TYP
RF CONNECTOR, TYP
11.9
7.
1
1 EQUIPMENT SPECIFICATIONS
SCALE: N.T.S.
NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED
BY REQUEST OF CUSTOMER WITHOUT EDIT.
SHEET NUMBER: REVISION:
R-602
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
PRELIM DEX 08/06/21
0
SUPPLEMENTAL
1 ANTENNA AND EQUIPMENT SUMMARY
SCALE: N.T.S.
NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED
BY REQUEST OF CUSTOMER WITHOUT EDIT.
SHEET NUMBER: REVISION:
R-603
SEAL:
DESCRIPTIONREV. DATEBY
ATC TOWER SERVICES, LLC
3500 REGENCY PARKWAY
SUITE 100
CARY, NC 27518
PHONE: (919) 468-0112
COA: 3408
DATE DRAWN:07/28/21
ATCJOBNO:
GARDINERCUSTOMERID:
13696084_G5
113079CUSTOMER #:
82962
ATCSITE NAME:
GARDINER #2 (WA)
GARDINER
1696 STARRT104
QUILCENE, WA 98376
ATC SITE NUMBER:
SITE ADDRESS:
VERIZON SITE NAME:
4515 S. MCCLINTOCK DRIVE, SUITE 217
TEMPE, AZ 85282
C O N S U L T I N G U S A
0 100% CDs AUD 08/30/21
PRELIM DEX 08/06/21
0
SUPPLEMENTAL
1 PLUMBING DIAGRAM
SCALE: N.T.S.
NOTE: THIS SHEET CREATED BY OTHERS AND PROVIDED
BY REQUEST OF CUSTOMER WITHOUT EDIT.