HomeMy WebLinkAboutBLD2022-00340_06 Floor Plan1 A3
.
3
7
'
-
0
"
1
0
'
-
6
"
5'
-
0
"
Me
c
h
.
Cr
a
w
l
S
p
a
c
e
Cr
a
w
l
S
p
a
c
e
17
5'
-
1
"
16
'
-
8
"
16
'
-
1
1
1
/
2
"
4
'
-
2
1
/
4
"
4
'
-
7
7
/
8
"
5
'
-
8
"
1
4
'
-
1
1
3
/
4
"
15
'
-
6
1
/
2
"
8'
-
6
1
/
2
"
AL
I
G
N
W
/
M
A
I
N
BE
D
R
O
O
M
W
I
N
D
O
W
UN
F
I
N
I
S
H
E
D
UN
H
E
A
T
E
D
7'
-
0
3
/
8
"
3
P
A
N
E
L
S
L
D
G
D
R
2'
-
1
0
"
F
I
N
I
S
H
7
'
-
1
1
1
/
2
"
FI
N
I
S
H
8'
-
2
"
4
A3
.
3
1.OPENINGS REQUIRING HEADERS SHALL BE 4x8 DF#1 UNLESS NOTED OTHERWISE.2.
B
U
I
LDER SHALL CONFIRM ALL BEAM SIZES WITH STRUCTURAL ANALYSIS. BUILDER IS TO NOTIFY DESIGNER OF ANY DISCREPANCIES BEFORE CONSTRUCTION. 3.
S
M
OKE DETECTORS LINKED TOGETHER ALL FLOORS.4.
A
L
L
BEDROOMS SHALL HAVE AT LEAST 1 EGRESS WINDOW.5.
H
ANDRAILS SHALL BE 36" MEASURED VERTICALLY FROM NOSING OF TREAD, BE 1" MIN ROUND, BE CONTINOUS THE FULL LENGTH OF STAIRS.6.
A
L
L
WINDOWS SHALL COMPLY WITH IRC SECTION FOR TEMPERED GALZING. 7.
S
T
AIR HEADROOM CLEARANCE 6'-8" MIN. FINISH.8. WATER HEATERS SHALL BE ANCHORED. TEMPERA TURE AND RELIEF VALVES SHALL TERMINATE OUTSIDE BUILDING. 9.
D
RYER VENTS SHALL TERMINATE OUTSIDE THE BUILDING. TOTAL DUCT LENGTH SHALL NOT EXCEED 14'.10. ******************11. SMOKE & CO DETECTORS AND FAN LOCATIONS SHOWN ON ELECTRICAL FLOOR PLANS.12. ALL USABLE SPACES UNDER STAIRS SHALL BE 1 HOUR FIRE CONSTRUCTION.13.
B
U
I
L
D
E
R
T
O
C
O
N
F
I
R
M
A
L
L
DIMENSIONS BEFORE CONSTRUCTION. 14. FIRE BLOCKING SHALL BE PROVIDED EVERY 10' HORIZ AND 8' VERT. AT CEIL'G AND FLOOR LEVELS.15. ALL VENTILATION DISCHARGE POINTS AT EXTERIOR OF HOUSE SHALL TERMINATE NO LESS THAN 3' FROM OPENABLE WINDOW. 16. DOOR OFFSETS ARE 5" UNLESS CENTERED IN OPENINGS.17. VERTICAL WINDOW MULLIONS ARE DBL STUD U.N.O.18. NON -BEARING INTERIOR WALLS SHALL BE 2x4 @ 16" O.C. UNLESS SPECIFIED OTHERWISE.20. ALL DIMENSIONS ARE TO FACE OF STUD OR FRAMING U.N.0.21. EXCEPTIONS: EAST, NORTH, WEST AND SOUTH EXTERIOR WALLS. SEE DETAIL 6/A5.2GENERAL NOTES
2 A3
.
3
3
A3
.
3
4
'
-
2
1
/
4
"
2
A3
.
4
3 A3
.
4
1 A3.4
4
A4
.
2
3
0
'
-
0
"
2
'
-
0
"
13
'
-
7
"
2'
-
5
1
/
2
"
1
'
-
6
"
WE
D
I
S
Y
S
S
T
E
P
I
N
ME
T
E
R
B
A
S
E
DB
L
S
T
U
D
AC
C
E
S
S
PA
N
E
L
AI
R
HA
N
D
L
E
R
HE
A
T
P
U
M
P
HO
T
W
A
T
E
R
TA
N
K
A
B
C
12
30
"
x
3
0
"
A
C
E
S
S
PA
N
E
L
KN
O
C
K
O
U
T
FO
R
C
O
L
D
V
E
N
T
UN
F
I
N
I
S
H
E
D
UN
F
I
N
I
S
H
E
D
UN
F
I
N
I
S
H
E
D
3
A5
.
2
3'
-
3
7
/
8
"
3'
-
9
1
/
4
"
4'
-
7
"
9'
-
1
0
1
/
2
"
10
'
-
1
"
3
'
-
3
3
/
4
"
3
'
-
3
7
/
8
"
A5
.
1
8
Co
l
d
R
o
o
m
Do
o
r
3'
-
8
"
EL
E
C
T
.
PA
N
E
L
4'
-
7
"
6x
6
3/
0
x
6
/
8
3/
0
x
6
/
8
3
/
0
x
6
/
8
3/
0
x
6
/
8
3/
0
x
6
/
8
3/
0
x
6
/
8
9'
-
1
1
/
8
"
5'
-
8
7
/
8
"
8'
-
1
1
"
54
'
-
0
"
SH
E
A
R
W
A
L
L
8'
-
4
1
/
8
"
UN
F
I
N
I
S
H
E
D
UN
F
I
N
I
S
H
E
D
5
1
/
2
"
5
3
/
8
"
5
1
/
2
"
HA
N
D
R
A
I
L
4x
4
P
O
S
T
11
'
-
1
1
"
32
'
-
1
"
22' - 0"
Co
l
d
R
o
o
m
Xm
a
s
St
o
r
.
HE
A
T
P
U
M
P
1
UP
P
.
5
HE
A
T
E
D
HE
A
T
E
D
HE
A
T
E
D
HE
A
T
E
D
HE
A
T
E
D
HE
A
T
E
D
8
"
1'
-
0
"
GR
I
L
L
E
GR
I
L
L
E
GR
I
L
L
E
IN
-LI
N
E
>
1
0
C
F
M
F
A
N
WI
S
P
E
R
Q
U
I
E
T
8"
x
6
"
D
U
C
T
VE
N
T
G
R
I
L
L
E
ME
C
H
A
N
I
C
A
L
V
E
N
T
A
L
I
T
I
O
N
42
3
S
F
/
5
0
S
F
=
8
.
4
6
C
F
M
R
E
Q
.
VE
N
T
VE
N
T
FN
D
V
E
N
T
FN
D
V
E
N
T
FN
D
V
E
N
T
FN
D
V
E
N
T
VE
N
T
12
"
x
8
"
Date Drawn byPort Townsend , WA 983 360.643.3690 henry@designsbysouz a
8/
2
6
/
2
0
2
2
7
:
5
3
:
2
6
A
M
A2.1New Home for Lyn & Bruce Zoellick Lyn & Bruce Zoellick 6/1 Project Status: Permit 6/13/2022
1/
4
"
=
1
'
-
0
"
1
Lo
w
e
r
L
e
v
e
l
P
l
a
n
Ad
d
e
n
d
u
m
1
Re
m
o
v
e
d
U
t
i
l
i
t
y
s
i
n
k
a
n
d
a
l
l
r
o
u
g
h
-in
n
o
t
e
s
Ad
d
e
d
"
H
E
A
T
E
D
"
t
o
a
l
l
r
o
o
m
s
h
e
a
t
e
d
AD
D
E
N
D
U
M
2
:
8
/
2
5
/
2
0
2
2
FO
U
N
D
A
T
I
O
N
V
E
N
T
S
(
5
)
E
A
S
T
W
A
L
L
(2
)
S
O
U
T
H
W
A
L
L
ME
C
H
A
N
I
C
A
L
V
E
N
T
I
L
A
T
I
O
N
42
3
S
F
/
5
0
S
F
/
C
F
N
=
8
.
4
6
C
F
M
RE
C
E
I
V
E
D
B
Y
D
C
D
8
/
2
9
/
2
0
2
2
RECEIVED BY DCD 6/14/2022