HomeMy WebLinkAboutshold septic22OSS SITE PLANHadlock MotelParcel # 901024046, 048, 097SEC 2 TWP 29N R 1W050'100'SCALE 1"=50 FEETdrawn by:reviewed:MPJGEXPIRES 12/27/2022located by:APXsee noteX - NOTE:Lawn Street R.O.W .181 ChimacumRoadBuildingsContoursDrainfieldStump / TreeProperty lineSet backsWaterSoil logsSHOLD EXCAVATING 360-385-0480SHEET 1 OF 1901024046901024048901024097901024005Chimacum Road175 ChimacumRoad42 Lawn StreetDF bed 3DF bed 2DF bed 1DF bed 4DF bed 5DF bed 6SEP2003-00094SEP2007-00170SEP1977 0024130'45'40'80' 5'33'90°141'25'reserve area*reserve area*10'SEPTIC PERMITTING NOTES: SEP2003-1994 incorporates tanks and six drainfield beds serving 175 Chimacum Road and 181 Chimacum Road.SEP2007-00170 added a tank for the motel facility at 181 Chimacum Road.SEP1977-00241 serves 41 Lawn Street.pump linessssssSEP2003-00094Approved Capacity: -SEP2003-1994 and SEP2007-00170 are approved for a combined peak capacity of 2300 gallons per day. Recommended use is at 75% of peak capacity, daily use is limited to 1725 gallons per day.-SEP1977-00241 is approved for a peak capacity of 240 gallons per day, with a recommended daily useof 180 gallons per day.Setbacks (for easement): -Easements for disposal components (beds) and reserve areas require 5' from easement line to edge of bed / reserve area.-Transport / sewer lines require 2' setback to easement lines.-Transport lines to beds 1-3 (not shown) run along the east side of the disposal beds. Any easement created meeting the 5' disposal component setback along the easterly portion of the beds will also meet the setback requirements for the associated transport lines.The bed corners are staked with 3' lath with red / white / blue ribbon. Transport lineis marked with green marking paint. Reserve Area Notes: -Reserve areas shown are based on a review of the existing permit information. Location and size were determined using my best judgement / interpretation of the source information. While it is considered to represent the intended area, no warranty of accuracy exists, and Jefferson County Public Health has not reviewed or approved this interpretation.5/3/22There is a marking in the location of the red x indicating a drainfieldlateral (marked DF in green paint). This is an error, and this markingshould be disregarded. Compliance Notes: 1-There is a non permitted RV connection on P/N901024097 (42 Lawn Street) which connects to SEP2003-00094. 2-A large portion of SEP1977-00241 is under the existing gravel parking area on 42 Lawn Street.-Both of these conditions represent a violation of Jefferson County Sewage Code. rotating distribution valve