Loading...
HomeMy WebLinkAboutSEP2012-00020 - 02 PERMIT SEWAGE DISPOSAL PERMIT Jefferson County Department of Community Development 621 Sheridan Street, Port Townsend WA 98368 (360) 379-4450 PERMIT#: SEP12-00020 Date Received: 02/28/12 SITE ADDRESS: 410 N BEACH DR Date Issued: 04/06/12 PORT LUDLOW, WA 98365 Date Expires: 07/06/12 APPLICANT: J WILLIAM DEDERER PHONE: ELINE C DEDERER 410 N BEACH DR PORT LUDLOW WA 983659272 LEGAL DESCRIPTION: BRIDGEHAVEN DIV.2 LOTS 2&3 PARCEL#: 934200003 Section: 9 Township: 27N Range: 01 E DESIGNER: MIKE DEENEY PHONE: (800)395-7296 CREATIVE DESIGN SOLUTIONS PO BOX 2787 PORT ANGELES WA 98362 DISCLAIMER- This approval is for an on-site sewage system that meets the state and county standards in effect on the date of application. This approval for an on-site sewage system DOES NOT assure you of any other County approvals. For example, it DOES NOT GUARANTEE that you will later obtain permission to build a permanent residence or other structure on this parcel. Any future application will be separately judged by the rules and laws in effect at that time. ALL CONSTRUCTION AND DEVELOPMENT ACTIVITIES MUST COMPLY WITH ALL PERMIT CONDITIONS, STATE AND LOCAL CODES, AND RECOMMENDED STANDARDS AND GUIDANCE DOCUMENTS IN EFFECT WHEN THE PERMIT IS ISSUED. Permit issued to CONSTRUCT,ALTER, REPAIR OR MODIFY AN INDIVIDUAL SEWAGE DISPOSAL SYSTEM IN JEFFERSON COUNTY,WASHINGTON Thls permit is issued for a period of three years (unless otherwise stated above) in accordance with Jefferson County Rules and regulations for on-site sewage systems, codified 8.15 amended per ordinance no. 06-0719-07. This permit may not be renewed. Jefferson County Environmental Health Specialist The property owner is responsible for the accurate location of all property lines.Any removal of or major disturbance of soil in the primary or reserve drainfield area may create site conditions that are unacceptable for the installation of a sewage disposal system. Any change in drainfield or tank location may invalidate this permit unless prior approval is obtained from the Jefferson County Environmental Health Division. If during excavation or development of the site an area of potential archeological significance is uncovered, all activity in the immediate area shall be halted, and the UDC Administrator shall be notified at once. HEALTH DEPARTMENT MUST BE CALLED FOR FINAL INSPECTION. SYSTEM DESCRIPTION: 160-SAND LINED BED No. of Gallons per Day: 240 Type of work: REP Drainfield Trench Septic Tank Length: 24 feet Width: 10feet Depth: 50 inches Size: 1,000 gallons SPECIAL CONDITIONS APPLY - SEE REVERSE CONDITIONS OF APPROVAL - PERMIT NO.: SEP12-00020 1.) PRIOR TO CONSTRUCTION the Installer must verrify the existing water line location and mainatin a 10' minimum setback to any septic component 2.) This permit was issued to correct a violation of WAC 246-272A. The permit must be completed within 90 days of the date of issuance. 3.) This system must be constructed by an installer certified by the Jefferson County Public Health Department per state code WAC246-272A-0250. 4.) H - Existing tank shall be properly abandoned. It shall be pumped and filled with clean fill. Documentation to be provided to Health Dept. prior to final. 5.) H - AS PER WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 ALL ONSITE SEWAGE SYSTEMS REQUIRE THAT A RESTRICTIVE COVENANT REGARDING THE MONITORING OF THE ONSITE SEPTIC SYSTEM BE RECORDED TO THE PROPERTY TITLE. THE PROPERTY OWNER SHALL ASSURE THAT MONITORING IS PROVIDED BY AN APPROVED ENTITY AT THE FREQUENCY DEFINED PER STATE WAC 246-272A AND JEFFERSON COUNTY CODE 8.15 AS ADOPTED OR AMENDED. A COPY OF THE RECORDED OPERATIONS AND MONITORING AGREEMENT IS REQUIRED PRIOR TO FINAL APPROVAL OF THE SEWAGE DISPOSAL PERMIT 6.) Bed TO BE EXCAVATED TO 48" DEPTH AND THEN BACKFILLED WITH ASTM 33 TYPE SAND TO 24"AND UP SIDE WALLS AS PER DESIGN. 7.) Health Dept. required to observe pressure test with system designer when system fully installed/complete, 48 hours notice to be provided for scheduling. 8.) Designer must be contacted prior to start of construction and for inspections during installation. DESIGNER IS REQUIRED TO DO A PRECOVER INSPECTION ON ALL TYPES OF SYSTEMS. 9.) Notification of the start of construction shall be faxed or emailed to Jefferson County Public Health ONE WORKING DAY prior to start. 10.) H -An asbuilt drawing and certification of completion by the designer is required prior to final approval. 11.) Before final approval is given, the designer shall provide an operations and maintenance manual to the property owner and the Health Department. The manual must instruct the owner of the on site sewage system on the ways to properly operate and maintain all components of the system. 12.) Setback to surface waters- 100' required from drainfield and reserve areas. 50' required from tanks. 13.) Contact designer prior to installation for staking of drainfield area. 14.) Approval/issuance of a sewage disposal permit does not guarantee the approval of other development or a building permit on this site. Compliance with other Jefferson County and Washington State Codes is required. 15.) All construction and development activities must comply with all permit conditions, Washington State and Jefferson County Codes and Recommended Standards and Guidance documents in effect when the permit is issued. 2 of 3 11/22/19 I:\F_SEP_Permitmod.rpt 16.) Divert all sources of drainage, including roof drains away from septic tank and drainfield area. 17.) Low use water fixtures recommendred, 1.6 gal. flush toilets and 2.5 gpm shower heads. 18.) Approval of this sewage disposal permit does not preclude the permit holder from complying with the Unified Development Code for other/future development on the site. 19.) The project shall adhere to the Best Management Practices(BMPs)to control stormwater, erosion and sediment during construction. BMPs shall address permanent measures to stabilize soil exposed during construction, and in the design and operation of stormwater and drainage control systems. 20.) The project proponent shall adhere to all conditions in the shoreline exemption permit issued for installation of the septic system under MLA12-00054. 3 of 3 11/22/19 I:\F_S E P_Perm itmod.rpt