Loading...
HomeMy WebLinkAboutExhibit 02_OlyCAP Caswell-Brown Village_Conditional Use Permit Application Set Page 1 DEPARTMENT OF COMMUNITY DEVELOPMENT 621 Sheridan Street, Port Townsend, WA 98368 Tel: 360.379.4450 | Fax: 360.379.4451 Web: www.co.jefferson.wa.us/communitydevelopment E-mail: dcd@co.jefferson.wa.us CONDITIONAL USE PERMIT Purpose The purpose of the conditional use permit process is to provide flexibility in the application of the use regulations contained in the Jefferson County Code (JCC) in order to accommodate uses that may be appropriate in an established district under certain circumstances, but inappropriate in the same district under other circumstances. The conditional use permit information sheet is designed to help you provide all the information necessary to facilitate a timely and well- informed decision on your application. You will use the Master Land Use Permit Application Form for all Conditional Use applications. Conditional use approval may involve either a Type II or Type III review process under the JCC, depending on the specific type of use. No conditional use permit can be granted unless consistency with the performance standards of JCC 18.20, the development standards of JCC 18.30 , the procedural requirements of Article VIII, Chapter 18.40 JCC, and other applicable requirements of the JCC have been satisfied. Types of Conditional Uses Conditional uses are typed and identified in Table 3-1 of the JCC, or may be classified as such by the Administrator pursuant to Article II, Chapter 18.15 JCC. There are three broad types of conditional uses identified in the JCC. Conditional [“C”] Use: Proposed uses that require a discretionary approval process and a public hearing before the Hearing Examiner. Applications for uses listed as a "C" in Table 3-1 of the JCC are processed according to the procedures for Type III land use decision established in Article VIII, Chapter 18.40 JCC. Conditional Administrative [“C(a)”] Use: Proposed uses that require approval by the Administrator but do not require a public hearing. Applications for uses listed as an administrative conditional use permit (i.e., "C(a)") in Table 3-1 of the JCC are processed according to the procedures for Type II land use decisions established in Article VIII of Chapter 18.40 JCC. Conditional Discretionary [“C(d)] Use: Proposed uses that, at a minimum, require approval by the Administrator but that, at the discretion of the Administrator, may be referred to the Hearing Examiner for a public hearing and final decision. Applications for uses listed as discretionary conditional use permits (i.e., "C(d)") in Table 3-1 of the JCC are, at a minimum, processed according to the procedures for Type II land use decisions established in Article VIII of Chapter 18.40 JCC. However, pursuant to JCC 18.40.520, the Administrator may on a case-by-case basis refer a discretionary conditional use permit application to the Hearing Examiner to be processed according to the procedures for Type III land use decisions. In order to refer a "C(d)" application to the Hearing Examiner, the Administrator must make one of the following findings:  In the exclusive, discretionary judgment of the Administrator, the application involves potentially significant issues relating to location, design, configuration, and potential impacts to surrounding properties and the community that can be more appropriately considered and addressed through a public hearing before the Jefferson County Hearing Examiner; or  In the exclusive, discretionary judgment of the Administrator, the application seeks approval of a use involving complex legal issues necessitating special expertise in the decision-maker. Process Step 1 – Pre-Application Conference: A pre-application conference is required for all conditional use permits. Conceptual plans, county requirements, future permit requirements, etc., and answers to related questions are discussed at the conference. Information provided by Department of Community Development staff helps the applicant to prepare a better application and potentially decreases code-related questions and time required for formal review. Step 2 – Determination of Completeness: Following submittal of your application, county staff will make a determination within 28 days as to whether your application is substantially complete. Step 3 – Formal Application Review and Decision: Following the determination of completeness, a final decision must be made by the county within 120 calendar days. The final decision may be made by either the Administrator (for all “C(a)” and certain “C(d)” uses) or the Hearing Examiner (for all “C” and certain “C(d)” uses) depending on the type of conditional use. Public hearings before Page 2 the Hearing Examiner are required for all “C” uses and may be required for certain “C(d)” uses. In all conditional use permit cases the decision may be appealed. Approval Criteria Your conditional use application will be evaluated on the basis of the criteria listed in the relevant section of the Jefferson County Code (see JCC 18.40.530), and in some instances, inspection of the property. The county may approve or approve with modifications an application for a conditional use permit (i.e., uses listed in Table 3-1 as "C(a)," "C(d)" or "C") only if all of the following criteria are satisfied:  The conditional use is harmonious and appropriate in design, character and appearance with the existing or intended character and quality of development in the vicinity of the subject property and with the physical characteristics of the subject property;  The conditional use will be served by adequate infrastructure including roads, fire protection, water, wastewater disposal, and storm water control;  The conditional use will not be materially detrimental to uses or property in the vicinity of the subject parcel;  The conditional use will not introduce noise, smoke, dust, fumes, vibrations, odors, or other conditions or which unreasonably impact existing uses in the vicinity of the subject parcel;  The location, size, and height of buildings, structures, walls and fences, and screening vegetation for the conditional use will not unreasonably interfere with allowable development or use of neighboring properties;  The pedestrian and vehicular traffic associated with the conditional use will not be hazardous to existing and anticipated traffic in the vicinity of the subject parcel;  The conditional use complies with all other applicable criteria and standards of this Code and any other applicable local, state or federal law; and more specifically, conforms to the standards contained in 18.20 and 18.30 of this Code;  The proposed conditional use will not result in the siting of an incompatible use adjacent to an airport or airfield;  The conditional use will not cause significant adverse impacts on the human or natural environments that cannot be mitigated through conditions of approval;  The conditional use has merit and value for the community as a whole;  The conditional use is consistent with all relevant goals and policies of the Jefferson County Comprehensive Plan; and  The public interest suffers no substantial detrimental effect. Consideration shall be given to the cumulative effect of similar actions in the area. In instances where all of the above findings cannot be made, the application shall be denied. The County, in accordance with JCC 18.40.540, may impose additional conditions on a particular use if it is deemed necessary for the protection of the surrounding properties, the neighborhood, or the general welfare of the public. The county may add conditions which:  Increase requirements in the standards, criteria or policies established by the JCC;  Stipulate an exact location for the conditional use on the subject property as a means of minimizing hazards to life, limb, property damage, erosion, landslides or traffic;  Require structural features or equipment as a means of minimizing hazards to life, limb, property damage, erosion, landslides or traffic; or  Contain restrictions or provisions deemed necessary to establish parity with uses permitted in the same zone with respect to avoiding nuisance generating features in matters of noise, odors, air pollution, wastes, vibration, traffic and physical hazards. Approval of the conditional use is effective for three (3) years from the date of original approval. If a building permit has not been issued within the three (3) year period, the conditional use approval will expire. Minor modifications to a previously approved conditional use may be approved subject to the provisions of JCC 18.40.570. Page 3 DEPARTMENT OF COMMUNITY DEVELOPMENT 621 Sheridan Street, Port Townsend, WA 98368 Tel: 360.379.4450 | Fax: 360.379.4451 Web: www.co.jefferson.wa.us/communitydevelopment E-mail: dcd@co.jefferson.wa.us SUPPLEMENTAL APPLICATION CONDITIONAL USE MLA # PROJECT/APPLICANT NAME: The purpose of the conditional use permit process is to provide flexibility in the application of the use regulations contained in the Jefferson County Code (JCC). No conditional use permit can be granted unless consistency with the performance standards of JCC 18.20, the development standards of JCC 18.30, the procedural requirements of JCC 18.40.280, and the approval criteria of JCC 18.40.530, and other applicable requirements of the UDC have been satisfied. Approval of the conditional use is effective for three (3) years from the date of original approval. If a building permit has not been issued within the three (3) year period, the conditional use approval will expire. The following questions will assist in the evaluation of the conditional use request: 1. Describe the requested conditional use. 2. Explain how the conditional use is harmonious and appropriate in design, character and appearance with the existing or intended character and quality of development in the vicinity and with the physical characteristics of the subject property. 3. Describe the infrastructure including but not limited to roads, fire protection, water, wastewater disposal, and stormwater control which will serve the requested conditional use. 4. Describe the location, size, and height of buildings, structures, signage, walls and fences, and screening vegetation for the use. 5. Describe any noise, smoke, dust, fumes, vibrations, odors, outdoor lights or other impacts will be generated by the conditional use. 6. Describe the pedestrian and vehicular traffic and parking area associated with the conditional use. Page 4 7. Will the proposed conditional use result in the siting of an incompatible use adjacent of an airport or airfield? 8. Are there any significant adverse impacts on the human and natural environments caused directly by the conditional use? If yes, can these impacts be mitigated? 9. Describe how granting the conditional use will not be materially detrimental to uses or property in the vicinity of the subject parcel. 10. Describe how granting the conditional use will not be substantially detrimental to the public interest. 11. Does the conditional use have merit and value for the community as a whole? 12. Describe how the conditional use complies with all other applicable criteria and standards of the Jefferson County Code (JCC) and any other applicable local, state or federal law; and more specifically, conforms to the standards contained in JCC 18.20 and JCC 18.30. 13. Describe how the conditional use is consistent with all relevant goals and policies of the Jefferson County Comprehensive Plan. ACKNOWLEDGEMENT By signing the application form, the applicant/owner attests that the information provided herein is true and correct to the best of his/her knowledge. Any material falsehood or any omission of a material fact made by the applicant/owner with respect to this application packet may result in this permit being null and void. (APPLICANT OR AUTHORIZED REPRESENTATIVE SIGNATURE) (DATE) [NOTE: Representative authorization is required if application is not signed by the Owner.] PROPOSED RV AND TENT SITE (83,600 SF) PHASE IIa, PAHSE IIb N E W E N T R Y D R IV EMILL ROAD(E ) R E S E R V E S E P T IC D R A IN F IE L D F O R L O W E R V IL LA G E 1 6 0 X 6 5 PROPOSED PRIMARY SEPTIC DRAINFIELD FOR SHELTER + HOUSING FACILITY200' X 100'(E) LARRY SCOTT TRAILF A C IL IT Y E N T R Y D R IV E PROPOSED PEDESTRIAN CONNECTOR 142 MILL ROAD PORT TOWNSEND 001162001N 07*08'47" E337.02'S 88*01'15" E 104.54'N 4 1 * 1 9'3 9 " W7 4 6 .8 0'S 2*01'25" W 707.57' N 87*58'35" W 986.21'NEW DRIVEWAYE X IS T IN G D R IV E W A Y LIMITS OF EXISTING RV AND TENT SITE (PHASE IIa, IIb) LIMITS OF PHASE I RV AND TENT SITE (41,350 SF)(N) DRAINFIELD160X65P R O P O S E D S H E L T E R A N D H O U S IN G F A C IL IT Y PROPOSED GRAVEL PARKING LOT (10 VISITOR SPACES) (2219 SF) 16 % 6%16 %14%2 5 %2 2 %6% 6%6%3 %(E) VEGETATED SWALE STORMWATER RETENTION BASIN PRESERVED STORMWATER DISPERSION AREA 5%7%8%9%1 0%6%(E) LARRY SCOTT TRAIL(E) LARRY SCOTT TRAILW W W W W W W W W S P P P P P P P PARKING PARKING/ SERVICE APPROX. OUTLINE OF EXISTING FORREST BUFFER, TYP. SEPTIC TANK ARRAY 38X16 LIGHT POLE, TYP. P 30' - 0" MIN. P R O P O S E D R E S E R V E S E P T IC D R A IN F IE LD F O R S H E LT E R + H O U S IN G F A C ILIT Y 200' X 1 0 0 '1 0'- 0 " MI N . 1 0 '-0" M IN .1 0 '-0" M IN .PROPOSED STORMWATER DISPERSION AREA (E) VEGGETATED LANDSCAPED BUFFER TO REMAIN, TYP. MAINTAIN EXISTING 30' VEGETATED BUFFER 55' - 0"26' - 0" W CENTRAL FACILITIES BLDG. ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:14 PMG001 COVER SHEET 10/17/22 22032 GG/SS JD/GG 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village PROJECT IMAGE PROPERTY OWNER: OLYMPIC COMMUNITY ACTION PROGRAMS (OlyCAP) 2120 WEST SIMS WAY PORT TOWNSEND, WA 98368 PH: (360) 301-3109 CONTACT: KATHY MORGAN, DIRECTOR OF HOUSING ARCHITECT: SMR ARCHITECTS 117 SOUTH MAIN ST SUITE 400 SEATTLE, WA 98104 PH: 206.623.1104 CONTACT: SCOTT STARR / GEORGE GIBBS DESIGN TEAM: ADDRESS OF PROPERTY: 142 MILL ROAD, PORT TOWNSEND, WA 98368 ASSESSOR PARCEL NO.: 001162001 LEGAL DESCRIPTION: S16 T30 R1W TAX 1(LESS TAX 42, 43, 48 & 49) TAX RR1 SUBJ/EASE CASWELL-BROWN VILLAGE (Shelter Camp) ZONING: RR-20 - Rural Residential DEPARTURES: PROJECT DESCRIPTION: NEW PERMANENT SUPPORTIVE HOUSING AND EMERGENCY SHELTER FACILITY WITH (17) PERMANENT SUPPORTIVE HOUSING UNITS, (3) FAMILY SUPPORT UNITS, (11) WOMEN'S EMERGENCY SHELTER BEDS, (11) MEN'S EMERGENCY SHELTER BEDS, (2) PRIVATE EMERGENCY SHELTER UNITS, RESTROOM AND SHOWER FACILITIES, A COMMON KITCHEN AND LIVING AREAS, RECEPTION AREA, AND (2) PRIVATE STAFF OFFICES. PROJECT INFORMATION: SITE AREA: 950,044 SF; APPROX. 21.81 ACRES BUILDING FOOTPRINT: 10,850 SF BULIDING HEIGHT: 23.667 FT BUILDING AREA: 11,034 SF CONSTRUCTION: TYPE VB PROPOSED # OF UNITS: 16 PERMANENT SUPORTIVE HOUSING UNITS, 24 EMERGENCY SHELTER BEDS/UNITS : 40 BEDS/UNITS TOTAL PROJECT DATA: VICINITY MAP SHEET INDEX SITE HWY 20MILL RDW SIM S W AY PORT TOWNSEND PAPER MILL PORT TOWNSEND 000 INDEX - SCHEMATIC DESIGN SHEET NO.SHEET NAME G001 COVER SHEET A001 SITE PLAN A101 LEVEL 1 FLOOR PLAN A102 ROOF PLAN A200 EXTERIOR ELEVATIONS A300 BUILDING SECTIONS 6 SCALE: 1" = 60'-0" KEY SITE PLAN1 NO DATE DESCRIPTION x x x x x x x x COMMON GARDEN AREACOMMON GARDEN AREAACCESSIBLE PEDESTRIAN CONNECTOR (TO RV AND TENT SITE)PARKING AND TRASH ACCESS WALK (ASPHALT) PROPOSED EMERGENCY SHELTER AND PERMANENT SUPPORTIVE HOUSING FACILITY DROUGHT TOLERANT GROUND COVER / NATIVE PLANT SPECIES SPECIMEN TREE, PRIVATE GARDEN EXISTING GRAVEL DRIVEWAYEXISTING GRAVEL DRIVEWAY PATIO (CIP CONC.) DECORATIVE FENCE TRASH COLLECTION 247 SF 9' - 0"(8 STALLS TOTAL)ADA AND STAFF PARKING18' - 0"46' - 1 1/2"18' - 0" GRAVEL GRAVEL TRASH COLLECTION AREAPARKING / EMERGENCY VEHICLE TURNAROUND PARKING AND TRASH ACCESS WALK (ASPHALT)UTILITY AND EXIT ACCESS WALK (ASPHALT) (10 STALLS TOTAL) VISITOR PARKING (9 STALLS TOTAL)TENANT / VISITOR PARKING18' - 0"19' - 10 3/4"ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:00 PMA001 SITE PLAN 12/28/18 22032 Checker Author 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village SCALE: 1" = 10'-0"1 SITE PLAN 0 5'10'20' NO DATE DESCRIPTION 3 A200 4 A200 2 A300 1 A200 2 A200 1 A300 80' - 7"25' - 3"5' - 2 1/2"19' - 8"5' - 2 1/2"25' - 3"PATIO8' - 6"15' - 2 1/2"84' - 0 3/4"32' - 7 3/4"40' - 0"8' - 3 1/4"4' - 5 1/4"18' - 2"18' - 10"30' - 1"171' - 10 1/2" 19' - 0"58' - 11"24' - 0"21' - 0"8' - 11 1/2"40' - 0" 64 SF RR/SHOWER 64 SF RR/SHOWER 137 SF PRIVATE ROOM 137 SF PRIVATE ROOM 993 SF WOMEN'S SHELTER 993 SF MEN'S SHELTER 244 SF RECEPTION 100 SF OFFICE 102 SF OFFICE 426 SF FAMILY UNIT 426 SF FAMILY UNIT 428 SF FAMILY UNIT 64 SF RR/SHOWER 64 SF RR/SHOWER 137 SF P.S.H. UNIT 137 SF P.S.H. UNIT 563 SF CENTRAL LIVING AREA (SHELTER) 154 SF MECH 123 SF WATER 176 SF ELEC PATIO 31' - 0" PATIO 40' - 0"PATIO8' - 9"17' - 3"21' - 4"18' - 1"109 SF ENTRY 2' - 5 1/2"3 A300 64 SF RR/SHOWER 64 SF RR/SHOWER 64 SF RR/SHOWER 64 SF RR/SHOWER 1' - 6" 359 SF KITCHEN 108 SF LAUNDRY 74 SF STAFF RR 137 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 94 SF P.S.H. UNIT 93 SF P.S.H. UNIT 95 SF P.S.H. UNIT 98 SF MAIL/LOCKERS 463 SF DINING/FLEX 4' - 4 1/2" T.W. 3'-6" TYP. T.W. 3'-6" TYP. T.W. 4'-6" TYP. OUTLINE OF ROOF OVERHEAD OUTLINE OF ROOF OVERHEAD FULL LITE DOOR FULL LITE DOOR SITTING AREA SPECIMEN TREE AND VIEWING GARDEN 19' - 7 3/4"19' - 7 3/4"19' - 9" VCT VCT VCT VCT VCT POLISHED/SEALED CONC. VCT FLOORING IN SLEEPING ROOMS, TYP. LVP 2176 SF CIRCULATION 482 SF CENTRAL LIVING AREA (SHELTER) ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:01 PMA101 LEVEL 1 FLOOR PLAN 12/28/18 22032 Checker Author 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village SCALE: 1/8" = 1'-0"1 LEVEL 1 0 4'8'16' NO DATE DESCRIPTION 2 A300 1 A300 2' - 0"2' - 0"2' - 0"4' - 0 1/2" 2' - 0"2' - 0"2' - 0"1' - 0"161' - 5" 84' - 0 3/4"32' - 7 3/4"44' - 8 1/2"92' - 1 3/4"62' - 2 3/4"20' - 1"9' - 9 3/4"84' - 6"22' - 3"12' - 6 3/4"14' - 1 1/4"22' - 10 1/2"4' - 5 1/4"8' - 3 1/4"82' - 1 1/2"20' - 3 1/4"74' - 2 1/2" 176' - 7 1/4"3 : 12SLOPE3 : 12SLOPEFINISH FACE OF EXTERIOR WALL BELOW TYP. 3 A300 3 : 12SLOPE4' - 4 1/2" SHEET METAL BOX GUTTER/SCUPPER SHEET METAL BOX GUTTER/SCUPPER STANDING SEAM METAL ROOF STANDING SEAM METAL ROOF STANDING SEAM METAL ROOF SHEET METAL BOX GUTTER/SCUPPER ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:02 PMA102 ROOF PLAN 12/28/18 22032 Checker Author 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village SCALE: 1/8" = 1'-0"1 ROOF 0 4'8'16' NO DATE DESCRIPTION 2 A300 1 A300 STANDING SEAM METAL ROOF FIXED VINYL WINDOW, TYP. FIBER CEMENT SIDING FIXED VINYL WINDOW, TYP. SHEET METAL BOX GUTTER/SCUPPER 23' - 7 1/2"3 A300 FULL LITE THERMALLY BROKEN HM DOOR AND FRAME, TYP. FIXED VINYL WINDOW, TYP.VINYL CASEMENT WINDOW, TYP. FIBER CEMENT SIDING, TYP.23' - 7 1/2"3 A300 VINYL CASEMENT WINDOW, TYP. FIXED VINYL WINDOW, TYP. FULL-LITE THERMALL BROKEN HM DOOR AND FRAME, TYP. FIBER CEMENT PANEL SIDING, TYP 23' - 7 1/2"1 A300 THERMALLY BROKEN HM DOOR AND FRAME FIBER CEMENT PANEL SIDING VINYL CASEMENT/FIXED WINDOW ASSEMBLY, TYP TERMALLY BROKEN ALUM. FRAMED WINDOW WALL (2) 3-0 X 8-0 FULL LITE WOOD ENTRY DOORS IN THERMALLY BROKEN HM FRAME (BOTH SIDES VESTIBULE) FIXED VINYL WINDOW, TYP. 6X6 WOOD POST, CIP CONC BASE VINYL AWNING WINDOW, TYP. FIXED VINYL WINDOW, TYP. STANDING SEAM METAL ROOF SHEET METAL BOX GUTTER/SCUPPER 23' - 7 1/2"ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:08 PMA200 EXTERIOR ELEVATIONS 12/28/18 22032 Checker Author 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village SCALE: 1/8" = 1'-0"1 EXTERIOR ELEVATION -NORTH SCALE: 1/8" = 1'-0"3 EXTERIOR ELEVATION -EAST SCALE: 1/8" = 1'-0"2 EXTERIOR ELEVATION -WEST SCALE: 1/8" = 1'-0"4 EXTERIOR ELEVATION -SOUTH NO DATE DESCRIPTION 993 SF WOMEN'S SHELTER 993 SF MEN'S SHELTER 64 SF RR/SHOWER 64 SF RR/SHOWERPATIO 12 3 12 3 12 1/2 8' - 2 1/2"8' - 4 1/2"23' - 8"VINYL CLERESTORY WINDOWS WOOD TRUSS ROOF FRAMING SECURE VIEWING GARDEN 12 3 12 3 13' - 8 1/2"23' - 8"8' - 5 1/2"11' - 3 1/2"463 SF DINING/FLEX 93 SF P.S.H. UNIT 4" SLAB ON GRADE 2" XPS PERIMETER INSULATION, TYP. VINYL CLERESTORY WINDOWS WOOD TRUSS ROOF FRAMING 563 SF CENTRAL LIVING AREA (SHELTER)23' - 8"64 SF RR/SHOWER 137 SF P.S.H. UNIT 64 SF RR/SHOWER 137 SF PRIVATE ROOM 4" SLAB ON GRADE TYP. 463 SF DINING/FLEX TYP. 4' - 0" 2" XPS PERIMETER INSULATION, TYP. VINYL CLERESTORY WINDOWS WOOD TRUSS ROOF FRAMING ISSUED SETS TITLE PERMIT # DRAWN CHECKED ISSUE DATE JOB NO. SHEET NO.: 117 S. Main St., Suite 400 SMR Architects Seattle, WA 98104 PH: 206.623.1104 FX: 206.623.5285 SDCI STAMP REVISIONS / NOTES DATE DESCRIPTIONNO SDOT # MUP #10/17/2022 1:22:09 PMA300 BUILDING SECTIONS 12/28/18 22032 Checker Author 142 Mill Road Port Townsend Washington 98368 Caswell-Brown Village SCALE: 1/8" = 1'-0"1 BUILDING SECTION 01 SCALE: 1/8" = 1'-0"2 BUILDING SECTION 02 SCALE: 1/8" = 1'-0"3 BUILDING SECTION 03 4" SLAB ON GRADE 2" XPS PERIMETER INSULATION, TYP. NO DATE DESCRIPTION