Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Site Plan_revised
DW W W W W W W GSDSDSD P P P P P P P P P 5' SIDEYARD SETBACK APPROXIMATE STREAM OHWM LOCATION 50FT STREAM SETBACK PROPERTY LINE16 0 ' S E T B A C K PROPOSED PARKING AREA 5' SIDEYARD SETBACK R. P.PROPOSED RESIDENCE W T. 1 0 0 ' S E T B A C K PROPOSED UNDERGROUND PROPANE TANK PROPERTY LINE PROPERTY LINE DABOB BAY APPROVED SEPTIC DRAINFIELD LOCATION PER SEP2022-00114 OHWMP 1 5 0 ' S E T B A C K EXISTING DRIVE WELL LOCATION 100FT WELL RADIUS REPORTED POWER UTILITY BOX PROPOSED SEPTIC TANK W W W GPARKING AREA SEPTIC FIELD SEPTIC TANK PROPOSED STRUCTURE AREA OF LAND DISTURBANCE, TYP. ESTIMATED LAND DISTURBANCE = 12,950± SF UTILITIES, TYP. OVERALL SITE PLAN A1.0 3309 WALLINGFORD AVE. N SEATTLE, WA 98103 PH: 206.728.0480 WWW.McCLELLAN-TELLONE.COM © 2024 MCCLELLAN | TELLONE PROJECT: RATHVON RESIDENCE 660 TWANA WAY QUILCENE, WA 98376 CLIENT: RICH & RENEE RATHVON AUGUST 15, 2024 DATE: SHEET TITLE: SHEET: 01 McCLELLAN TELLONE REV PHASE / ISSUE DATE 06/24/24PERMIT SET 08/15/24PERMIT REVISION 1 1 OVERALL SITE PLAN 1" = 30'-0" N DEVELOPMENT SUMMARY SITE AREA: 238,273 ft² IMPERVIOUS COVERAGE:25% = 59,568 ft² FRONT YARD: NA SIDE YARDS:5 ft REAR YARD:5 ft SHORELINE:150 ft + 10 ft BUILDING HEIGHT:35 ft IMPERVIOUS COVERAGE CALCULATIONS PERMITTED: 59,568 ft² / 25% EXISTING DRIVEWAY = 4,300 ft 2 ROOF AREA = 3,676 ft 2 PARKING AREA = 1,304 ft 2 DECKS = 60 ft 2 WALKWAYS = 148 ft 2 TOTAL PROPOSED: 9,488 ft² / 4% 2 LIMITS OF WORK 1" = 50'-0" N 01 DWW W W W W W W W W W W W GGGGP P P P PSS SDSDSD SDSDSD SD SD P P P P COVERED TERRACE PROPOSED RESIDENCE PRIMARY SUITE DECK EX. DRIVE 16 0 ' S E T B A C K GARDEN 87.0' T.O. SBFR +88 WALK WAY +89+87 PARKING AREA ENTRY +74 +76 +86 +86 +76 +86 +74 +76 +86.5 +86 +86 +89 +73 +76 +72 1 0 0 ' S E T B A C K 26'-6"58'-8" ± TO PROPERTY LINE447'-4" ± TO PROPERTY LINE PRECAST CONCRETE PAVERS, TYP CONCRETE PARKING AREA WITH CURB LINE OF ROOF ABOVE, TYP. OUTDOOR SHOWER BELOW PROPOSED SEPTIC TANK APPROVED SEPTIC DRAINFIELD LOCATION POWER UTILITY BOX UNDERGROUND UTILITIES. CONTRACTOR TO VERIFY FINAL PLACEMENT, TYP. ds ds ds ds DISPERSION BLOCK PER STORMWATER PLAN, TYP. NOTE: REF. STORMWATER MGMT. PLAN PER CIVIL ENGINEER 15 0 ' S E T B A C K 34'16' 17'-3" V.I.F.24'25' V . I.F . 14'-6" 9 ' -1 0 " 9'-6"4' 26'-6"80'16' 30' ENLARGED SITE PLAN A1.1 3309 WALLINGFORD AVE. N SEATTLE, WA 98103 PH: 206.728.0480 WWW.McCLELLAN-TELLONE.COM © 2024 MCCLELLAN | TELLONE PROJECT: RATHVON RESIDENCE 660 TWANA WAY QUILCENE, WA 98376 CLIENT: RICH & RENEE RATHVON AUGUST 15, 2024 DATE: SHEET TITLE: SHEET: 01 McCLELLAN TELLONE REV PHASE / ISSUE DATE 06/24/24PERMIT SET 08/15/24PERMIT REVISION 1 N 1 ENLARGED SITE PLAN 1/8" = 1'-0"