HomeMy WebLinkAboutSEP1995-00336 y1 47-N-t
615 Sheridan Street
so
Port Townsend,WA 98368
www-leffersoriCountyPubiTcHeatih.org
SUSAN RANDOLPH December 29, 2015
PO BOX 373
CHIMACUM WA 98325
RE: NOTICE AND ORDER TO CORRECT-Septic System Corrections Required
Septic System Monitoring Inspection
SITE ADDRESS: 9182 RHODY DR
PARCEL#: 901142017
CASE#: SOM95-00336
Dear SUSAN RANDOLPH:
On February 16, 2015 a monitoring inspection was completed on the above referenced property.
The following issues noted below require correction:
1. The on-site wastewater inspection indicated that there was a grey water pipe from the
laundry room area into an open trench. You are required to plumb all wastewater into the
approved onsite sewage system. An inspection by Jefferson County staff is required to verify
that this connection has been completed.
Because the sewage effluent is not being properly treated or disposed of, the observed discharging of
sewage to the surface of the ground or to the waters of the State of Washington constitutes a violation of
the following section/s of Jefferson County Code 8.15:
> JCC 8.15.070 (1) No Discharge to Ground or Surface
> JCC 8.15.150 (1)Operations, Maintenance and Monitoring
Jefferson County Public Health hereby gives you notice to correct the violations identified above within
thirty days of the date of this notice by doing the following:
> Immediately prevent gray water/sewage from discharging to the ground surface;
> Contact this office at 360-385-9444 to inform me of the actions you are taking.
This letter is intended to serve as formal notice that no further approvals shall be granted until
corrections are made and approved by Health Department staff. Failure to comply with this notice and
order to correct may result in the issuance of a civil infraction notice to you pursuant to section 180 of
said regulations. The civil infraction notice may result in a fine of up to$513.00 per violation per day to
be assessed to you.
The purpose of proper maintenance is so the County,for the benefit and protection of the public's
health, is assured by this department that these systems are designed, installed and maintained in a
proper manner. We appreciate your prompt attention to this matter and if you should have further
questions please contact this office at 385-9444.
Please note that pursuant to JC Code 8.15.170 of the above regulations that any person aggrieved by
the contents of a Notice and Order to Correct Violation issued under this regulation, or by any inspection
or enforcement action conducted by Jefferson County Public Health under this regulation may request,
in writing, a hearing before the Health Officer or his/her designee. Such request shall be presented to
the Health Officer within 10 business days of the action appealed. Such a hearing, if requested by you,
will be your sole opportunity to present live testimony and witnesses in support of your position.
Sincerely,
Environmental Health Specialist
Jefferson County Public Health
360-385-9444
c: File, O&M Provider
Code References
JCC 8.15.060(3) Adequate sewage disposal required. Any new or replacement residence or commercial structure,or
any expansion,as that term is defined in Section 8.15.050 of this Code,may be connected to a pre-existing on-site sewage
system only when the pre-existing system has hydraulic capacity,sufficient vertical and horizontal separation,an adequate
reserve area and satisfies all other requirements to be in compliance with current code.
JCC 8.15.080(1) On-site sewage system permit. No person shall install or cause to be installed a new on-site
sewage system nor perform any modification,extension,repair,relocation,or connection to an existing on-site sewage system
without a valid permit issued by the health officer.
JCC 8.15.170(1)Appeal-Hearing. Appeal of Public Health Action-Health Officer Administrative Hearing.Any person
aggrieved by the contents of a notice and order to correct violation issued under this regulation,or by any inspection,permit
issuance or enforcement action conducted by public health under this regulation,may request,in writing,a hearing before the
health officer or his or her designee.The appellant shall submit specific statements in writing of the reason why error is assigned
to the decision of public health.Such request shall be presented to the health officer within 10 business days of the action
appealed;except in the case of a suspension,the request for a hearing must be made within five business days.Upon receipt of
such request together with hearing fees,the health officer shall notify the person of the time,date,and place of such hearing,
which shall be set at a mutually convenient time not less than five business days nor more than 30 business days from the date
the request was received.The health officer will issue a decision upholding or reversing public health's action.The health officer
may require additional actions as part of the decision.
WAC 246-272A-0200 Permit Requirements. Prior to beginning the construction process,a person proposing the installation,
repair,modification,connection to,or expansion of an OSS,shall report the following and obtain a permit from the local health
officer:
(a) General information...
(b) The soils and site evaluation as specified under WAC246-272A-220
(c) A dimensioned site plan...
(d) A detailed design...
JCC 8.15.150 Operation,Maintenance and Monitoring
(1) Responsibility of Owner(s). The owner of every residence,business,or other place where persons congregate,reside or
are employed that is served by an OSS,and each person with access to deposit materials in the OSS shall use,operate,and
maintain the system to eliminate the risk to the public associated with improperly treated sewage. Owners'duties are included,
without limitation,in the following list:
a. They shall comply with the conditions stated on the on-site sewage permit.
b. They shall employ an approved pumper to remove the septage from the tank(s)when the level of solids and scum indicates
that removal is necessary. The septic tank shall be pumped when the total amount of solids equals or exceeds one-third(1/3)
the volume of the tank. The pump and/or siphon chamber(s)shall be pumped when solids are observed.
c. They shall not use water in quantities that exceed the OSS's designed capacity for treatment and disposal.
d. They shall not deposit solid,hazardous waste,or chemicals other than household cleaners in the OSS.
e. They shall not deposit waste or other material that causes the effluent entering the drainfield to exceed the parameters of
residential/household waste strength.
f. They shall not build any structure in the OSS area or reserve area without express,prior consent of the Health Officer.
g. They shall neither place nor remove fill over the OSS or reserve area without express,prior consent of the Health Officer.
h. They shall not pave or place other impervious cover over the OSS or reserve area.
i. They shall divert drains,such as footing or roof drains away from the area of the OSS.
j. They shall comply with inspection requirements in JCC 8.15.150 and WAC 246-272A
k. They shall complete maintenance and repair of the OSS as recommended by the monitoring entity.
1. They should not dispose of excess food waste via a garbage disposal.
m. They should not drive,park or store vehicles or equipment over the drainfield or reserve area.
n. They should not allow livestock access to the OSS area or reserve area.
o. They shall comply with WAC 246-272A-270.
(2) Breach of Owner's Responsibilities. An owner's or occupier's failure to fulfill any of the responsibilities in 8.15.150(1)
shall be a basis for a Notice of Violation and for the Health Officer to decline to issue approval for further development on the
parcel.
11/3/2015
Env/to Check LLC
1612 Hastings Ave. West 360379-9400
Port Townsend, WA 98368
PROPERTY INFORMATION •
House
Location:9182 RHODY DR
Chimacum
Tax ID:901142017
Mail To: Federal Nat'l Mtg Asc
800 Brooksedge Blvd Use:Residential,Single Family
Westerville,Oh System Design Flow:480
43081 GENERAL SYSTEM TYPE:Gravity
Owner:Federal Nat'l Mtg Asc
ON ID:SOM95-00336
Fold ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT Fold
Here Here
Inspected:02/16/2015 - Inspection Type:PROPERTY SALE - Correction Status:Some Corrections Made
Company: Work Performed By: Submitted 02/16/2015 by:
Enviro Check, LLC Dale Wurtsmith Dale Wurtsmith
This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development.
COMMENTS&GENERAL INSPECTION NOTES
Deficiencies Noted:deficiencies must be corrected to ensure proper longevity of the Onsite Sewage System.
1-The septic tank needed to be pumped and was by Enviro Check,LLC on 021615.
2-Risers are mandatory on next inspection(Date of 021618)
3-There is a small trick of water coming into the tank from inlet pipe.Need to locate water source and correct.
4-There appears to be a grey water pipe from laundry room area that extends into open trench.It is unknown where it is going.A flow test
laundry room to septic tank was done,but no detectible water flow was seen.Contact County regarding issue.
5-A revised"Plot Plan"is en route to County,Ref-Grey water line only.SYSTEM-What I observed on permitted system was consistent with plan.
GENERAL SITE&SYSTEM CONDITIONS
The General Site and System Conditions were: Fully Inspected
All Components accessible for maintenance,secure and in good condition: NO-See Comments
Surfacing effluent from any component(including mound seepage): NO
Components appear to be watertight-no visual leaks: YES
Improper encroachment(roads,buildings,etc.)onto component(s): NO
Component settling problems observed: NO
Abnormal ponding present for one or more of the disposal components: N/A
Subsurface components adequately covered YES
Owner compliance issues noted NO
Site maintenance required(e.g.Landscape maintenance)If yes,describe in comments: NO
Occupant compliance problem(occupant not operating the system properly). If YES,describe in notes: NO
If deficiencies were identified on last inspection were they corrected before or during this inspection'? N/A
(If NO,describe in notes,NA=no deficiencies on last report):
OSS Components,structures and appurtenances located per as-built/record drawing(If NO,describe NO-See Comments I
in notes). If no as-built exists or changes made,state NO and provide record to Health Dept:
Alterations made to the OSS(valves adjusted,timer settings modified,ports installed,etc.)(If YES, NO
describe in notes):
The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. YES-See Comments
Is the SEP case in a finaled/completed status?(if NO explain in comments) YES
ONSITE SEWAGE SYSTEM INSPECTION DETAIL
TANK:Septic Tank-2 Compartment 1000 gal
This component was: Fully inspected
Component appears to be functioning as intended: YES
Effluent level within operational limits(if NO explain in comments): YES
All required baffles in place(N/A=No baffles required): YES
Effluent Filter Cleaned(N/A=Not Present): N/A
Compartment 1 Scum accumulation(Inches,if other specify): 20
Effluent filter/screen needed cleaning on arrival N/A
Compartment 1 Sludge accumulation(Inches,if other specify): 20
Compartment 2 Scum accumulation(Inches,if other specify): o
ReportiD:422893 View inspection reports online at www.onlinerme.com Page 1 of 2
Compartment 2 Sludge accumulation(Inches,if other specify): 20
Pumping needed: YES See Comments
Approximate Gallons to be pumped(if needed)by Certified Pumper: 1000
grainfield:Gravity
This component was: Fully Inspected
Component appears to be functioning as intended: YES
Ponding present?If YES explain in comments: N/A
This report indicates certain characteristics of the onsite sewage system at the time of visit.In no way is this report a guarantee of operation or future performance.
ReportID:422893 View inspection reports online at www.onlinerme.com Page 2 of 2
r - --. c,3.1btS Tay VALE �,J aM .sMrrid raft- ��`Tog ob r._ -•r$i of�i F.1
I\09p. 5-°t1`aa 4Z1;la.Py QQ.t&181 MA„/„, APN zip( tit a01-7 (Gwr7 wrtT eRL: Mc mpLy)
5E ''Zit 1--33 to
._-._'FO OFRCE USE ONLY FOR F^WALL*VSPEC71ON M)INFORMATION A APPROVAL
SYSTEM INSTALLED BY t�ti �
rr �∎ rli /<
ABSORPTION AREA:
Nrffli ' c`loO iMDTN 3C�' uE +� �� s 1C3C l�
PRESSURE TEST OBSERVED A. 5 l v �DJ�
APPROVED tke- ` SPECIAUST Lt.(Y C,` A-1-.1(1(1.S DATE 1a-k k C
COMMEN!�TS: l 1 tk Qt[h1 '�,pw,�, y) ( `4- .(� ee.C�
+lQ" .u...rin c h Q to tocc k;r,, ` -t-'art '� !CI S.4 ovi
col-0 voltP a.w►° dwfi .
SIe+K
r 0 A
"II' 44P N.
, i -_,.. t-k,s
by rr(iiI
-ii(i
N E PERMIT NUMBER
v3ccu
o, St5`r� f cr,r%. ct�`-C� 3 Plot plan sub e
i
as a part of a Monitoring insper.Li)
Not reviewed or approved by JCrri,
ENVIB G//ECK Li.e.
1612 Hastings Ave. W.
Port Townsend, WA 98368
Q. a-s (Roc- ctja'