Loading...
HomeMy WebLinkAboutSEP1987-00019 (A1,91"fi- P,1 ric4/Ae , . , ,Include the following items on your plot:plant. it . Vit' Il`Property boundaries a Wells 15 2015 Gift Names of adjacent streets Septic tank .effersari aunty q( Driveways and parking spaces d Drainfield(enter NN if unc nment , alth o Surface water(ponds,creeks,etc) is North Arrow ia°3r � Z il Buildings(residence,sheds,garages,etc) i'....9 .Sc c0 GN %hf-4 Pare- /I/ar To fec/c PLOT PLAN-date prepared (O-/2,.. ^/3 / / J , flde?SGw lcl c d 71 ()F r r r t , i - f ( I--r,re vsi,:,,% / ( ,-/- )C• 'N „,,, ���auf�. Piot pian sUb �� d as a part Of a milted by`(� V—n Z7, z 3 t+.1,..0 / Not revi MO'�itorin9-7---- . ll-� �.__ - . 1 ewea or approves on b lobe y JCPH rep 710 r 'JrG�C ,1 c l 36 fS Permit#or Parcel# 90 r (6',l-o).) 7Q -600 ICI tem_07I30I04_edf par_e 2 of 5 Evaluation of an Existing Onsite Sewage Sys $4; tit 615 615 Sheridan Street Port Townsend, WA 98368 Public vwvw.JeffersonCountyPublicHealth.org WILLIAM A NYE JanuaryII, 2016 BARBARA A NYE PO BOX 659 CHIMACUM WA 98325 RE: Septic System Monitoring Inspection Report SITE ADDRESS: 2480 ANDERSON LAKE RD PARCEL#901101035 CASE#: SOM87-00019 Dear: WILLIAM A NYE On October 12, 2015 a monitoring inspection was completed on the above referenced property. This inspection found the following item/s of concern that require correction: 1. Water was found to be leaking into the septic tank around the lids. This must be repaired to prevent any leakage into the tank. The purpose of proper maintenance is so the County,for the benefit and protection of the public's health, is assured by this department that these systems are designed, installed and maintained in a proper manner. We appreciate your prompt attention to this matter. If you should have further questions please contact this office at 385-9444. The code sections referenced are attached for your information. This letter is intended to serve as formal notice that further approvals may be withheld until this work is completed and approved by Health Department staff. Postponing correction may result in premature failure of the septic system. A permit is required for any repair or modification of an onsite sewage system per Washington Administrative Code 246-272A and Jefferson County Code 8.15. Sincerely, 4+k Environmental Health Specialist Jefferson County Public Health 360-385-9444 c: File, O&M Provider Community Health Environmental Health Developmental Disabilities Water Quality 360-385-9400 360-385-9444 360-385-9401 (f) (f)360-379-4487 \\tidemark\data\forms\F_SOM_CorrReq_novio.rpt Code References 8.15.150 OPERATION,MAINTENANCE AND MONITORING (1) Responsibility of Owner(s). The owner of every residence,business,or other place where persons congregate, reside or are employed that is served by an OSS,and each person with access to deposit materials in the OSS shall use,operate,and maintain the system to eliminate the risk to the public associated with improperly treated sewage. Owners'duties are included,without limitation,in the following list: a. They shall comply with the conditions stated on the on-site sewage permit. b. They shall employ an approved pumper to remove the septage from the tank(s)when the level of solids and scum indicates that removal is necessary. The septic tank shall be pumped when the total amount of solids equals or exceeds one-third(1/3)the volume of the tank. The pump and/or siphon chamber(s)shall be pumped when solids are observed. c. They shall not use water in quantities that exceed the OSS's designed capacity for treatment and disposal. d. They shall not deposit solid,hazardous waste,or chemicals other than household cleaners in the OSS. e. They shall not deposit waste or other material that causes the effluent entering the drainfield to exceed the parameters of residential/household waste strength. f. They shall not build any structure in the OSS area or reserve area without express,prior consent of the Health Officer. Theyshall neither place nor remove fill over the OSS or reserve area without express,prior consent of the Health g. Officer. h. They shall not pave or place other impervious cover over the OSS or reserve area. i. They shall divert drains,such as footing or roof drains away from the area of the OSS. j. They shall comply with inspection requirements in JCC 8.15.150 and WAC 246-272A k. They shall complete maintenance and repair of the OSS as recommended by the monitoring entity. 1. They should not dispose of excess food waste via a garbage disposal. m. They should not drive,park or store vehicles or equipment over the drainfield or reserve area. n. They should not allow livestock access to the OSS area or reserve area. o. They shall comply with WAC 246-272A-270. (2) Breach of Owner's Responsibilities. An owner's or occupier's failure to fulfill any of the responsibilities in 8.15.150(1)shall be a basis for a Notice of Violation and for the Health Officer to decline to issue approval for further development on the parcel. 10112;2015 Goodman,Inc. 2495 Cape George Rd 360-385-7155 Port Townsend, WA 98368 PROPERTY INFORMATION Location:2480 ANDERSON LAKE RD Chimacum ID:90 Tax D:90 lUf Ta1101035 OCT Mail To: Bill Nye % �G c 2 0/5( (5 / G f 9 3 Use:Residential,Single Family System Design Flow:360 ,Enz'rsot. ,CFA GENERAL SYSTEM TYPE:GravditrnmOW)*eDte' y OwnerBill Nye Hee/ �. ON ID:SOM87-00019 Fold ON-SITE WASTEWATER TREATMENT SYSTEM INSPECTION REPORT s Fold Here Inspected:10/12/2015 - Inspection Type:ROUTINE - Correction Status:No corrections made Here Company: Certification-Level 1 Work Performed By: Submitted 10/12/2015 by: Goodman,Inc. Doug Nebel Doug Nebel This report does not assure approvals by Jefferson County Public Health for ANY future building permits or development. COMMENTS&GENERAL INSPECTION NOTES Deficiencies Noted:deficiencies must be corrected to ensure proper longevity of the Onsite Sewage System. Risers are mandatory on next inspection.new site drawing sent to H.D.Water entering around septic tank lids. GENERAL SITE&SYSTEM CONDITIONS The General Site and System Conditions were: Fully Inspected All Components accessible for maintenance,secure and in good condition: NO-Deficient Surfacing effluent from any component(including mound seepage): NO Components appear to be watertight-no visual leaks: NO-Deficient Improper encroachment(roads,buildings,etc.)onto component(s): NO Component settling problems observed: NO Abnormal ponding present for one or more of the disposal components: NO Subsurface components adequately covered YES Owner compliance issues noted NO Site maintenance required(e.g.Landscape maintenance)If yes,describe in comments: NO Occupant compliance problem(occupant not operating the system properly). If YES,describe in notes: NO If deficiencies were identified on last inspection were they corrected before or during this inspection? N/A (If NO,describe in notes,NA=no deficiencies on last report): OSS Components,structures and appurtenances located per as-built/record drawing(If NO,describe NO-Deficient in notes). If no as-built exists or changes made,state NO and provide record to Health Dept: Alterations made to the OSS(valves adjusted,timer settings modified,ports installed,etc.)(If YES, NO describe in notes): The house/structure was vacant or used infrequently,assessment of the drainfield was not possible. NO Is the SEP case in a finaled/completed status?(if NO explain in comments) YES ONSITE SEWAGE SYSTEM INSPECTION DETAIL •rainfield:Gravity This component was: Fully Inspected Component appears to be functioning as intended: YES Ponding present?If YES explain in comments: NO TANK:Septic Tank-2 Compartment This component was: Fully Inspected Component appears to be functioning as intended: YES Effluent level within operational limits(if NO explain in comments): YES All required baffles in place(N/A=No baffles required): YES Effluent Filter Cleaned(N/A=Not Present): N/A Compartment 1 Scum accumulation(Inches,if other specify): 0 Effluent filter/screen needed cleaning on arrival N/A Compartment 1 Sludge accumulation(Inches,if other specify): 8 Compartment 2 Scum accumulation(Inches,if other specify): 0 ReportiD:470674 View inspection reports online at www.onlinerme.com Page 1 of 2